American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

Similar documents
American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

ASSE International Product (Seal) Listing Program. ASSE Performance Requirements for Air Valve and Vent Inflow Preventer

ASSE International Product (Seal) Listing Program

ASSE International Product (Seal) Listing Program

Summary of Substantive Changes between the 2004 e1 and 2017 editions of ASSE 1011, Hose Connection Vacuum Breakers

American Society of Sanitary Engineering

IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC PURPOSE

Presented to the IAPMO Standards Review Committee on March 7, 2016

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS

TECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1

Summary of Substantive Changes between the 2012 and 2018 editions of CSA B125.3 Plumbing Fittings

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

American Society of Sanitary Engineering

Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections

REDUCED PRESSURE ZONE DEVICES SERIES PRODUCT CODES OPERATION HIGH HAZARD RATING. 15mm - 50mm FEATURES APPLICATION DESCRIPTION

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

1200B2 Series Service Regulators. Instruction Manual

Horizontal Bladder Tanks

Vertical Bladder Tanks

An Urgent Bulletin from CSA Group

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

PROCEDURES FOR REPAIRS TO ASME NV STAMPED PRESSURE RELIEF DEVICES OF NUCLEAR SAFETY RELATED PRESSURE RELIEF VALVES

Combination Air Valve

Flexible hoses - Non-metallic materials

Model MTB-ASME Vertical Bladder Tanks

SUBMITTAL NOTES PROJECT: Ross Model 50RWR-A Pilot Operated Surge Relief Valve with Hydraulic Anticipation. Size: inch / mm

Model MTB-ASME Horizontal Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks

Operation Manual. Diaphragm Sensed Gas Pressure Regulators

Installation Operation Maintenance

Type EZH Relief or Backpressure Regulator

Combination Air Valve Model

Speed control assembly model A-1

Type Testing of Rising Stem Valves Equipped with Graphite Packing for Fugitive Emissions

Cross Connection Control. 2 CE Hours

COMBINATION AIR RELEASE DEGASSING (CARD) VALVES INSTALLATION AND MAINTENANCE MANUAL

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

T208VR Series Tank Blanketing Vacuum Regulator

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

P r o d u c t R a n g e Data sheet: P

ANDERSON GREENWOOD. Provides reliable overpressure protection in a cost effective package. Flow Control

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

WHEATLEY Series 500 Swing Check Valve

Test Report # Rev 0. Adiabatic Compression In Nitrogen Service

SCA Series Inverted Bucket Steam Traps

Operation Manual Piston Sensed Gas Pressure Regulators

EMERGENCY WALL MOUNTED HAND OPERATED DELUGE SHOWER

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

TECHNICAL DATA Q= C. Table 1 - Specifications

CALEFFI. Reduced pressure zone backflow preventer. 574 series 01022/18 NA D E C F B D E. Function

WSC Performance Standard and Recommended Installation Procedures for Sanitary Water Well. Pitless Adapters, Pitless Units, And Well Caps

STANDARD FOR CONTROL VALVE SEAT LEAKAGE

RCS Rupture Disc Assembly

Date of Issue: July 2016 Affected Publication: API Specification 16C, Choke and Kill Equipment, Second Edition, March 2015 ADDENDUM 1

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS MATERIAL AND PROPERTY STANDARD FOR

Technical Standard Order

Smart Water Application Technologies (SWAT) TM

COSASCO 6000 PSI SINGLE ISOLATION SERVICE VALVE (FR) MAINTENANCE

WARNING: READ THE GENERAL INFORMATION MANUAL INCLUDED FOR OPERATING AND SAFETY PRECAUTIONS AND OTHER IMPORTANT INFORMATION.

COSASCO 3600 PSI SINGLE ISOLATION SERVICE VALVE (FR) MAINTENANCE

SUPPLY OF ISOLATION AND APPLIANCE VALVES PTS - APPLIANCE BALL VALVE

Operating Instructions

TECHNICAL DATA. Table 1 - Specifications

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve.

1800C and 1800C-HC Series Service Regulators

CASH VALVE TYPE KP BACK PRESSURE VALVES

TECHNICAL DATA. Q = C v P S

GREIG FILTERS, INC. OPERATION MANUAL

Pipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3

SECTION BUTTERFLY VALVES

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

Loss Prevention Standard

PRO-50 Instrument Supply Regulator

FloWash. Industrial Filter Cart

Safety Aspects and Design of the Vent Isolation Chamber. Prepared: W.M. Snow Checked: H. Nann Approved: W. M. Snow

Logic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm)

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

TECHNICAL DATA. Q = C v P S

SPECIFICATIONS - DETAILED PROVISIONS Section Butterfly Valves C O N T E N T S

SECTION PRESSURE TESTING OF PIPING

Portable Hydrostatic Electric Test Pump. Procedure Manual. Dixon 800 High Street Chestertown, MD Fax: dixonvalve.

Carter Option X Valve connector assembly. Maintenance manual

COSASCO 6000 PSI DOUBLE ISOLATION SERVICE VALVE MAINTENANCE

Bermad Pressure Reducing. Model: 42T

v. Size shall be specified on drawings.

TECHNICAL DATA OBSOLETE

S & M Water Consultants

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

Installation Instructions

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

Data Sheet Issue A

Transcription:

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM ASSE STANDARD #1019 - REVISED: 2011 Wall Hydrant with Backflow Protection and Freeze Resistance MANUFACTURER: CONTACT PERSON: E-MAIL: ADDRESS: LABORATORY FILE NUMBER: MODEL # TESTED: MODEL SIZE: ADDITIONAL MODELS REPORT APPLIES TO: ADDITIONAL MODEL INFORMATION (i.e. orientation, series, end connections, shut-off valves): DATE MODELS RECEIVED BY LABORATORY: DATE TESTING BEGAN: DATE TESTING WAS COMPLETED: IF MODELS WERE DAMAGED DURING SHIPMENT, DESCRIBE DAMAGES: PROTOTYPE OR PRODUCTION: WERE ALL TESTS PERFORMED AT THE SELECTED LABORATORY? Yes No If offsite, identify location and tests involved: General information and instructions for the testing engineer: The results within this report apply only to the models listed above. There may be items for which the judgment of the test engineer will be involved. Should there be a question of compliance with that provision of the standard, a conference with the manufacturer should be arranged to enable a satisfactory solution of the question. Should disagreement persist and compliance remain in question by the test agency, the agency shall, if the product is in compliance with all other requirements of the standard, file a complete report on the questionable items together with the test report, for evaluation by the ASSE Seal Board. The Seal Board will then review and rule on the question of compliance with the intent of the standard then involved. Documentation of material compliance must be furnished by the manufacturer. The manufacturer shall furnish to the testing agency, a bill of material which clearly identifies the material of each part included in the product construction. This identification must include any standards which relate thereto. LABORATORY EVALUATION REPORT ASSE STANDARD 1019-2011 PAGE 1

SECTION I 1.0 General 1.1 Application Does this device, as stated by the manufacturer, comply with this section? Yes No Questionable 1.2 Scope Does the device conform to the product classified as a wall hydrant with backflow protection and freeze resistance? Yes No Questionable 1.2.1 Is this hydrant a Type A, Type B, or Type C device? Type A Type B Type C 1.2.2 Sizes Size of male hose threaded outlet: Size of inlet connection: inches ( mm) inches ( mm) 1.2.3 Connections 1.2.3.1 Outlet Type: Complies with ASME B.20.7? Yes No 1.2.3.2 Inlet Type: Complies with plumbing code: 1.2.4 Pressure What is the working pressure range as noted by the manufacturer? psi to psi ( kpa to kpa) 1.2.5 Temperature Range What is the temperature range as noted by the manufacturer? F to F ( C to C) 1.2.7 Atmospheric Vent Is the atmospheric vent of a nonstandard plumbing connection? Yes No SECTION II 2.0 Test Specimens 2.1 How many devices of each type, model and size were submitted? If a series of devices is being evaluated, were devices having the smallest inlet and longest length in that series submitted for testing? Yes No Did the manufacturer supply the fouling procedure for Section 3.12? Yes No LABORATORY EVALUATION REPORT ASSE STANDARD 1019-2011 PAGE 2

2.2 How many devices of each type or model and size were utilized during the laboratory evaluation? 2.3 Drawings Were assembly drawings, installation drawings and other technical data which are needed to enable a testing agency to determine compliance with this standard submitted with the device? Yes No Questionable Were the drawings reviewed in the laboratory? Yes No SECTION III 3.0 Performance Requirements and Compliance Testing 3.1 Hydrostatic Pressure Test What was the test pressure? What was the water temperature used for this test? The test period was for minutes Was there any indication of damage or external leakage? Yes No 3.2 Water Flow Capacity What was the supply pressure used for the test? At a 25 psi (172.4 kpa) pressure differential across the device, what was the flow rate? GPM ( L/m) In compliance? Yes No 3.3 Deterioration at Maximum Rated Temperature and Pressure What was the flow rate used for this test? GPM ( L/m) What was the water temperature used for this test? What was the supply pressure used for this test? Duration of test: hours/days for days or continuous hours. 3.4 Life Cycle Evaluation Devices with a cold water inlet only: Water pressure used for this test : Was a flow restrictor used? Yes No What was the torque or force required to close the device? Rotary Torque: Axial Force: Devices with both a cold water inlet and a hot water inlet: Hot Water: Cold Water: LABORATORY EVALUATION REPORT ASSE STANDARD 1019-2011 PAGE 3

Water pressure used for this test: Was a flow restrictor used? Yes No What was the torque or force required to close the device? Rotary Torque: Axial Force: Device was cycled for: cycles at a rate of cycles per minute. Was there any leakage from the stem or atmospheric port(s) during the cycling test? Yes No 3.5 Resistance to Bending Load applied: Supply pressure used for this test: lbs ( kg) Was there any indication of external leakage or fracturing in the sill flange or body? Yes No 3.6 Self Draining Capabilities Type of device on test: Type A Type B Type C Water pressure used for this test: Temperature inside cold chamber while running test: Time required to lower device to 0.0 F (-17.8 C): minutes Once the temperature of the device inside the cold chamber was lowered to a maximum of 0.0 F (-17.8 C), was the device able to flow water? Yes No 3.7 Low Head Back Pressure The test period for each column reading was for minutes At each water column height, was there any leakage from the inlet of the device? Yes No 3.8 Outlet Pressure Release for Type A and Type B Devices The system was pressurized to: A quick acting valve dropped the pressure in the inlet to when the inlet pressure dropped to 0.0 psi (0.0 kpa). The outlet pressure release mechanism dropped the outlet pressure to: 3.9 Backflow Prevention for Type C Devices The system was pressurized to: LABORATORY EVALUATION REPORT ASSE STANDARD 1019-2011 PAGE 4

A quick acting valve dropped the pressure at the inlet to: The test period was for hours Was there any leakage into the inlet of the device? Yes No 3.10 Leakage from Vent Ports Pressure at the inlet with the device in the closed position: When opened to full flow, what was the flowing pressure? Was there any leakage from the vent ports at full flow? Yes No 3.11 Cross Flow Test (Mixing Hydrant Only) Was the mixed water outlet port blocked closed? Yes No Cold water inlet was pressurized to for minutes. Leakage at the hot port(s): Hot water inlet was pressurized to for GPM ( ml/min) minutes. Leakage at the cold port(s) GPM ( ml/min) 3.12 Backsiphonage All check valves and checking members in the normal water flow path of the device were fouled with a inch ( mm) diameter wire. A slowly applied vacuum was raised to and held for A rapidly applied vacuum was raised to and then relieved to The rise of water in the sight glass was: inches Hg ( kpa) minutes. inches Hg ( kpa) inches Hg ( kpa) inches ( mm) SECTION IV 4.0 Detailed Requirements 4.1 Materials Does the device comply with the material requirements of this standard? Yes No Questionable Were any check valves or relief venting of a metal to metal seating? Yes No LABORATORY EVALUATION REPORT ASSE STANDARD 1019-2011 PAGE 5

4.2 Markings 4.2.1 List the following information as shown on the device: (a) Manufacturer s name or trademark: (b) Model designation: (c) Type A : Type B : Type C : Were the markings visible on the installed position? Yes No 4.2.2 How were the markings applied? 4.3 Installation Instructions 4.3.1 Were installation instructions submitted with the device? Yes No LABORATORY EVALUATION REPORT ASSE STANDARD 1019-2011 PAGE 6

TESTING AGENCY: ADDRESS: PHONE: FAX: TEST ENGINEERS: We certify that the evaluations are based on our best judgement and that the test data recorded is an accurate record of the performance of the device on test. SIGNATURE OF THE OFFICIAL OF THE AGENCY: TITLE OF THE OFFICIAL: DATE: SIGNATURE AND SEAL OF THE REGISTERED PROFESSIONAL ENGINEER SUPERVISING THE LABORATORY EVALUATION: SIGNATURE: PE SEAL *To insert images into document (PE seal and signatures) Adobe Acrobat Pro users: At the top of the page, go to: Tools > Advanced Editing > TouchUp Object Tool. Once you have selected TouchUp Object Tool, right click within the document and select Place Image. Choose the image you want to place (PE seal or signature) and then select Open. Once the image is in the document, move and re-size the image accordingly. Save and send to ASSE. Adobe Reader users: Adobe Reader does not allow users to place images into the document. You must print this completed document and then sign and stamp the PE seal by hand. You may then send the completed document to ASSE via fax or mail, or you can scan the completed document and send via e-mail. COMMENTS: LABORATORY EVALUATION REPORT ASSE STANDARD 1019-2011 PAGE 7