Steel-Mass Model 640S

Similar documents
Steel-Mass Model 640S

780S Ultra High Purity Series

Ultra High Purity Model 780S

7Flat-Trak Model 780S. Smart In-Line Thermal Gas Mass Flow Meter with Flow Conditioner. For information online...

Features. Description

Technical Data Sheet High Performance Digital Gas Mass Flow Meters and Controllers Features Description

High Performance Digital Gas Mass Flow Meters & Controllers

Max-Trak Model 180. Technical Data Sheet. NEMA 6 / IP67 Compliant Industrial Mass Flow Meters and Controllers For Gases

C-1500 Series Velocity Transmitter for HVAC Application (Gas, Liquid) C Thermal Mass Flow Meters. Gas & Liquid Type Mass Flow meter

SmartTrak. High Performance Digital Gas Mass Flow Meters & Controllers. DESCRIPTION

analytical bulk flow distance FLOW level pressure temperature industrial communication

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

SmartTrak 100HP. Ultra-High Pressure Digital Gas Mass Flow Meters & Controllers. FEATURES DESCRIPTION

Pro-V Multivariable Flowmeter

PanaFlow MV82. Insertion Style Multivariable Flowmeter. GE Measurement & Control. Key Benefits. Applications

SideTrak 830/840. Process Gas Mass Flow Meters and Controllers. FEATURES DESCRIPTION

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

For Multi-Parameter Meters see mvx

QuadraTherm 640i/780i HIGH ACCURACY : FOUR-SENSOR : MASS FLOW METER

For Multi-Parameter Meters see mvx

Design Features. General Description

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Mass Ultrasonic / 2006 Flow meter INSTRUMENTS, INC. THE FLOW MEASUREMENT. HVA/C Mass Flow Meter (HVA/C 1510)

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

Model 601CV. Mass Flow Controller. Product Features:

Autocalibration Systems For In Situ Oxygen Analyzers

TransPort PT878GC Panametrics Portable Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

TransPort PT878GC Panametrics Ultrasonic Portable Gas Flowmeter. GE Infrastructure Sensing. Features. Applications

800 Series Mass Flow Meters and Controllers. High Performance Mass Flow Meters and Controllers

SITRANS P measuring instruments for pressure

Z, Y, and X PURGE INDICATORS / CONTROLLERS

Torque Tube TB300 Digital Transmitters

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

Autocalibration Systems for In Situ Oxygen Analyzers

Micro Motion 7812 Fiscal Gas Density Meter

Thermatel Model TA2 Mass Flow Transmitter

Over 20,000 Strain Gage Target flowmeters installed since 1952.

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

C-Flow Coriolis Mass Flow Meters

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

THERMAL MASS FLOW MEASUREMENT FOR GASES

Mass Flow Controllers

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

CORI-FLOW PRECISION MASS FLOW METER / CONTROLLER FOR LIQUIDS AND GASES

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司

Thermatel Enhanced Model TA2 Thermal Mass Flow Meter

Flow metering in gases Introduction to COMBIMASS family

3000 Series OPTIMASS Mass Flowmeter. Stainless Steel Hastelloy

How to specify a product. Process Sensors and Mechanical Instruments

TFE-LINED VAREA-METER PVC-TUBE VAREA-METER

TELEDYNE HASTINGS INSTRUMENTS PRELIMINARY BULLETIN. Models HFM-D-301 & 305, HFC-D-303 & 307

Level transmitter LT 100

Precision Mass Flow Meters / Controllers for Liquids and Gases

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features

Energy Management solutions for compressed air and industrial gases. vpinstruments.com

Smart performance with innovative and ever-strong coil drive even under harsh working environments

Technical Data Sheet. OPTIMASS 7000 Custody Transfer Mass Flowmeter

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

TransPort PT878GC Panametrics Ultrasonic Portable Gas Flowmeter. GE Sensing. Applications. Features

Thermal Energy Flowmeter Model KEC. Application Range. Special Features

ALL-IN-ONE MINI THERMAL MASS FLOWMETER

9700 Transmitter Submersible hydrostatic level transmitter

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

RCD - Ultra-Rugged Differential Pressure Flowmeter

EPR High Precision 3000 psi Electronic Pressure Controller Accurate to 0.25% of full scale

BUBBLER CONTROL SYSTEM

Differential Pressure Transmiter

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

TEK-THERMAL 1700B. Thermal Mass Flowmeter. FLOW. Technology Solutions

BUBBLER CONTROL SYSTEM

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN

Thermal Mass Flow Controllers for High Accuracy Process Gas Applications

Flow Meters and Flow Controllers

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

Micro Motion 3098 Gas Specific Gravity Meter

Deep Submersible Level Transducer Series 300DS

Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing

Mass Flow Controller (MFC) for Gases

TYPE APPROVAL CERTIFICATE

NT High-temperature flowmeter model Simultaneous flow and pressure outputs for high-temperature applications

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Model 4000 Pressure Controller

DigitalFlow GF868 Panametrics Flare Gas Mass Ultrasonic Flowmeter with Extended Performance Range

SLA5810/20/40 SLAMf10/20 Series

KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media

Expert Hydrostatic Level Transmitters

Model FT4X Thermal Mass Flow Meter & Temperature Transmitter

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

3.0 Pressure Transmitter Selection

Mass Flow Meter (MFM) for gases

Digital Mass Flow Meters and Controllers for Gases

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

KMT. Thermal Mass Flow Meter. for Compressed Air and Gases. Measuring range: m3n/h m3 N

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

Transcription:

Smart Insertion Thermal Gas Mass Flow Meter Features Direct mass flow monitoring eliminates need for seperate temperature and pressure inputs Accuracy +/- 1% of reading plus 0.5% of full scale Patented Dry-sense technology eliminates sensor drift State-of-the-art calibration facility insures a highly accurate calibration that matches the application Field validation of meter electronics and sensor resistance verifies flow meter performance One-second response to changes in flow rate FM, CSA, PED and ATE certified for hazardous areas CE approved high temperature option to 750F (400C) available Multipoint options available Integrated purge option available ow and high pressure hot taps available Optional MODBUS, Foundation Field BUS and Profibus PA available Steel-Mass Model 640S S Description ierra Instruments Steel-Mass Model 640S smart insertion mass flow meter is designed for he toughest industrial gas flow measurement applications. The versatile microprocessor-based transmitter integrates the functions of flow measurement, flow-range adjustment, meter validation and diagnostics, in either a probe-mounted or remote housing. Mass flow rate and totalized flow, as well as other configuration variables, are displayed on the meter s optional 2 x 12 CD display. The programmable transmitter is easily configured via an RS-232 communication port and Sierra s Smart Interface software, or via the display and magnetic switches on the instrument panel. Sierra's State-of-the-art calibration facility insures that the calibration will match the application, and our patented Drysense thermal sensor insures the Model 640S will hold this calibration over time. Sierra s Smart Interface software guides you through a procedure to fully validate instrument performance, thus field-verifying meter functionality. The meter is available with a variety of input power, output signal, mounting and packaging options. For information online... www.sierrainstruments.com The information contained herein is subject to change without notice.

Hazardous-Area ocation Enclosure Dimensional Specifications Tables Compression Fitting Side View (E2) 3/4-inch NPT, Typ. 1.9 (48.3).54 (13.7) Flange Mounting Side View (E2) 3/4-inch NPT, Typ. 1-inch ANSI, B16.5 150 lb Flange.54 (13.7) C 4.4 (111.8) Remote Mount Junction Box Side View (E4) 1/2-inch NPT, Typ. 1.6 (40.6).54 (13.7) 4.7 (119.4) Remote Mount Side View (E3, EEx only) Compression Fitting Front View (E2) 4.7 (119.4).75 Flange Mounting Front View (E2) 2.5 (63.5).75 Remote Mount Junction Box Front View (E4) Per Customer Cable ength Requirement, 200 Feet Maximum.75 4.7 (119.4) Remote Mount Front View (E3, EEx only) ength Chart (Compressions Fittings) Code 06 6.0 7.5 (152.4) (190.5) 09 9.0 10.5 (228.6) (266.7) 13 13.0 1 (330.2) (368.3) 18 18.0 19.5 (457.2) (495.3) 24 24.0 25.5 (609.6) (647.7) 36 36.0 37.5 (914.4) (952.5) ength Chart (Flange Mounting) Code 06 6.0 9.0 (152.4) (228.6) 09 9.0 12.0 (228.6) (304.8) 13 13.0 16.0 (330.2) (406.4) 18 18.0 21.0 (457.2) (533.4) 24 24.0 27.0 (609.6) (685.8) 36 36.0 39.0 (914.4) (990.6) ength Chart (Remote Mount Junction Box) Code 06 6.0 7.5 (152.4) (190.5) 09 9.0 10.5 (228.6) (266.7) 13 13.0 1 (330.2) (368.3) 18 18.0 19.5 (457.2) (495.3) 24 24.0 25.5 (609.6) (647.7) 36 36.0 37.5 (914.4) (952.5) Mounting Holes for Remote Bracket.50 (12.7) 3.00 (76.20) 1.5 (38) 3.0 (76) Per Customer Cable ength Requirement, 200 Feet Maximum Per Customer Cable ength Requirement, 200 Feet Maximum.31 φ (7.87), 2P All dimensions are inches. Millimeters are in parentheses. All drawings have a +/-.25-inch (6.4 mm) tolerance. Certified drawings are available on request.

Hazardous-Area ocation Enclosure Dimensional Specifications Tables Remote Rear Bracket Mounted Electronics Remote Side Bracket Mounted Electronics ength Chart (NEMA 4) Code 06 6.0 7.25 (152.4) (184.1) 3.0 (76.2) 10.07 (255.8) 7.25 (184.2) 5.0 (127) 09 9.0 10.25 (228.6) (260.3) 13 13.0 14.25 (330.2) (361.9) 18 18.0 19.25 (457.2) (488.9) 24 24.0 25.25 (609.6) (641.3) 36 36.0 37.25 (980.4) (946.1) Dimensional Specifications NEMA 4 Dimensional Specifications Purge Option High Temperature Option All dimensions are inches. Millimeters are in parentheses. All drawings have a +/-.25-inch (6.4 mm) tolerance. Certified drawings are available on request.

ow Pressure Hot Tap to 150 psig (10 barg) Side View VARIABES = Nominal Probe ength D = Duct O.D. C = Duct I.D. T = Height of Threadolet or Customer Provided Weldolet R = Restraint Cable ength FORMUA 12 + D/2 + T So must be equal or greater than 12-inches plus the height of the Threadolet plus half the duct O.D. D C 0.75 Duct Flow Inward C M2 Threadolet or Customer Supplied 1-inch Weldolet T 1-inch NPT Hex Nipple, 2P 1-inch NPT Ball Valve 3.3 (83.8) 4.3 (109.2) 10.8 (274.3) 4.0 (101.6) 6.5 (165.1) Restraint Cable, ength=r 1-inch NPT Hot Tap Packing Gland Probe 1.0 (25.4) 0.7 (17.8) 7.7 (195.6) R = D/2 + T + 8.8 High Pressure Hot Tap to 1000 psig (70 barg) All dimensions are inches. Millimeters are in parentheses. All drawings have a +/-.25-inch (6.4 mm) tolerance. Certified drawings are available on request. Unobstructed Flow Requirements Select an installation site that will minimize possible distortion in the flow profile. Valves, elbows, control valves and other piping components may cause flow disturbances. Check your specific piping condition against the examples shown below. In order to achieve accurate and repeatable performance install the flow meter using the recommended number of straight run pipe diameters upstream and downstream of the sensor. If you cannot meet these requirements please reffer to the Flat-Trak Model 780S with flow conditoning plates (flow conditioning plates reduce upstream requirements to as little as 2 diameters. Example A Upstream (1) Requirements 1 2 3 4 5 6 Example B Downstream (2) Requirements 1 2 3 4 5 6 1 20D 40D 1 30D 40D (1) Number of diameters (D) of straight pipe required between upstream disturbance and the flow meter. 10D 10D (2) Number of diameters (D) of straight pipe required downstream of the flow meter.

Performance Specifications Accuracy of Point Velocity +/- 1% of reading + 0.5% of full scale Repeatability +/- 0.2% of full scale Temperature Coefficient +/- 0.02% of reading per F within +/- 50 F of customer specified conditions +/- 0.03% of reading per F within +/- 50 F to 100 F of customer specified conditions +/- 0.04% of reading per C within +/- 25 C of customer specified conditions +/- 0.06% of reading per C within +/- 25 C to 50 C of customer specified conditions Pressure Coefficient.02% per psi for air, consult factory for other gases Response Time One second to 63% of final velocity value Operating Specifications Gases Most gases compatible with 316 stainless steel Hastalloy available Gas Pressure (2 limitations) Mechanical design pressure: Compression fittings: 500 psig (34 barg) 1-inch 150 lb flange (-40 to 250 F): 185 psig (12.8 barg) ow Pressure Hot Tap: 150 psig (10 barg) High Pressure Hot Tap: 1000 psig (70 barg) Pressure Drop Negligible for pipes three inches in diameter or larger Gas & Ambient Temperature Gas.............. -40 F to 350 F (-40 C to 177 C) Gas dependent. See mass flow range tables for details Ambient.......... -40 F to 120 F (-40 C to 50 C) eak Integrity 5 x 10-9 cc/sec of helium maximum Power Requirements 18 to 30 VDC (regulated), 625 ma maximum 100 to 240 VAC, 50/60 Hz, 15 watts maximum High Temperature Option Up to 750 F (400 C) air only; consult fatory for other gases Digital Communications Options Foundation Fieldbus (read only; flow and totalized flow) Profibus PA (read only; flow and totalized flow) MODBUS RTU (read/write most parameters) RS 232 (standard; command set available) Output Signal inear 0 5 VDC or 0-10 VDC, 1000 ohms minimum load resistance or inear 4 20 ma proportional to mass flow rate, 700 ohms maximum resistance power supply dependent User-selectable.. Active non-galvanically separated or Passive galvanically separated (loop power required) Alarms Hard contact user-adjustable high and low Dead band adjustable with Smart Interface software Relay ratings....... Maximum 400 VDC or VAC (peak), 140 ma Displays Alphanumeric 2 x 12 digit backlit CD Adjustable variables via on-board switches (password protected) or with Smart Interface software Adjustable variables.. Full scale (50 to 100 %) Time Response (1 to 7 seconds) Correction factor setting (0.5 to 5) Zero and span High and low alarm settings Totalizer Seven digits (9,999,999) in engineering units Resettable by software, on-board switches or external magnet Software Smart Interface Windows -based software Minimum 8 MB of RAM, preferred 16 MB of RAM RS 232 communication Additional features... Alarm dead band adjustment Zero cut-off adjustment inearization adjustment Save / oad configurations Flow meter validation Physical Specifications Wetted Materials 316 stainless steel Enclosure Hazardous-Area ocation Enclosure (IP66) or NEMA 4 (IP65) Both are powder-coated cast aluminum Electrical Connections Two 3/4 inch NPT... Hazardous-Area ocation Enclosure (IP66) One 1/2 inch NPT... NEMA 4 Enclosure (IP65) Mounting (optional) ANSI 1-inch 150 lb flange 3/4-inch tube compression fitting with 1-inch male NPT Hot tap systems Certifications CE (All enclosures) CSA (Explosion proof for Class I, Division 1, Groups B, C, D) ATE ( II 2 GD Ex d IIC T6... T2 IP 66 T70 C... T280 C ) FM (Explosion proof for Class I, Division 1, Groups B, C, D; dust-ignition proof for Class II, III, Division 1, Groups E, F, G) IP66, NEMA 4 T6-40 C to 70 C ambient Viton, Neoprene, Kalrez, and Teflon are registered trademarks of Dupont. Windows and Excel are registered trademark of Microsoft.

Ordering the Model 640S PARENT MODE NUMBER 640S Steel-Mass Industrial Insertion Meter 640S AGENCY APPROVAS NAA Non-Agency Approved Meter CSA Explosion Proof for Class I, Division 1, Groups B, C, D ATE II 2 GD Ex d IIC T6... T2 IP 66 T70 C... T280 C FM Explosion Proof for Class I, Division 1, Groups B, C, D PROBE ENGTH 06 6-inches (15 cm) 09 9-inches (23 cm) 13 13-inches (33 cm) 18 18-inches (46 cm) 24 24-inches (61 cm) 36 36-inches (92 cm) (in) Special ength (ength in Inches) (in)-m5 Probe with 1-Inch 150 lb Flange (ength in Inches) (in)-m9 High Pressure Hot Tap with Retractor (ength in Inches) MOUNTING ACCESSORIES 640S-M0 None 640S-M1 Compression Fitting (3/4-inch tube x 1-inch Male NPT) 640S-M2( ) Threadolet (3/4-inch Female NPT) Specify pipe O.D. in parentheses 640S-M3 Flat Duct Bracket (3/4-inch tube compression fitting) 640S-M4( ) Curved Duct Bracket (3/4-inch tube compression fitting) Specifiy duct O.D. in parentheses 640S-M8( ) ow Pressure Hot Tap. Specifiy duct O.D. in parentheses 640S-M15( ) Quick Removal Tap. Maximum 40 psig (2.8 barg) ENCOSURES E2 Hazardous-Area ocation Enclosure E3(ft) Remote Hazardous-Area ocation Enclosure E4(ft) Remote Hazardous-Area ocation Enclosure with Junction Box EN2 NEMA 4 EN4(ft) Remote NEMA 4 with Junction Box Specify Cable ength in Parentheses Maximum 200 ft (60 m). ength in Feet Using 5ft. Increments up to 20 ft., 10 ft. Increments up to 200 ft. INPUT POWER P2 18 30 VDC P3 100 240 VAC (Not Available on EN Enclosures) OUTPUT SIGNA V1 0 5 VDC, inear V3 0 10 VDC, inear V4 4 20 ma, inear DISPAY NR DD No Readout Digital Display GAS CODE 0 Air 1 Argon 2 CO 2 3 Chlorine (Correlation) 4 Digester 5 Digester (Correlation) 6 Helium 7 Hydrogen 8 CH 4 9 CH 4 (Correlation) 10 Nitrogen 11 Oxygen (Correlation) 12 Propane 13 Propane (Correlation) 99 Other OPTION 1 (DIGITA COMMUNICATIONS) PUSE Pulse (not avail. w/ E2-NR) MB MODBUS (not avail. w/ P3) FF Foundation Fieldbus (E2/P2 only) PB Profibus (E2/P2 only) OPTION 2 (PURGE) PURGE Includes valve, tube and purge nozzle. OPTION 3 (HIGH TEMPERATURE) HT To 750 F (400 C); Requires E4, EN4 remote option. SIERRA INSTRUMENTS, NORTH AMERICA 5 Harris Court, Building Monterey, California (800) 866-0200 (831) 373-0200 Fax (831) 373-4402 www. sierrainstruments.com SIERRA INSTRUMENTS, EUROPE Bijlmansweid 2 1934RE Egmond aan den Hoef The Netherlands +31 72 5071400 Fax: +31 72 5071401 OPTION 4 (CERTIFICATES) PT Pressure Test Certificate CC Certificate of Conformance NC NACE Certificate MC Materials Certificate NC NACE Certificate 640S B 5/08