Use of Overhead Protection Systems (OPS) in Refractory Lined Vessels.

Similar documents
FALL PROTECTION (SAF-SPI-06)

Inflatable Stretcher. Product Manual

HotWorks Harness Range User Weight Limits (*kg) - Harness to Lanyard - 160kg Attachment Hardware VVVV Rear D Alloy hardened steel for increased tensil

A GUIDE TO BUYING FALL ARREST EQUIPMENT. uk.rs-online.com (UK customers) (International customers)

Fall Protection ABC s

The Work At Height Safety Association

Fall Protection. 29 CFR Appendix C 29 CFR 1926 Subpart M

Height Safety Lifting Load Control

TECHNICAL DATA OBSOLETE

BANKSMAN / SLINGER. 1. What is the smallest size diameter of synthetic rope allowed for use as a hand held tagline?

Guidance on piling, heavy loads, excavations, tunnelling and dewatering

17J Third Edition, January 2008 Specification for Unbonded Flexible Pipe

Vertical and Horizontal Bladder Tanks

Description: 2 pcs PF2555CTN Delivery: March 3 rd CONTACT:

This training session provides important information on fall protection at construction sites. Anyone who is exposed to potential fall hazards must

250 (9.84) 170 (6.69) 225 (8.85) 75 (2.95) 300 (11.81)

Webbing. Tear Webbing Energy Absorber. Rope. Wire Rope. Sewing

??????? is committed to providing a safe work environment for its employees and preventing occupational injuries due to falls.

POWER LIFT LOW PRESSURE LIFTING BAGS. Instructions for use

Operation and Maintenance Manual

Suitability of Work Equipment

APPLICATION OF DRYACIDE DUST FOR THE STRUCTURAL TREATMENT OF GRAIN SILOS, BINS AND GRAIN STORES

CABLEGRIPS GALVANISED STAINLESS ARAMID FOR QUICK AND EFFICIENT CABLE INSTALLATION AND SUPPORT

SPUD OWNER S MANUAL ALWAYS WEAR A COAST GUARD APPROVED FLOTATION DEVICE WHEN OPERATING THE SPUD KAYAK.

ENERGY BLADE 3K4. Energy Blade Installation Instructions

Evacuation Raft. Product Manual

SAFETY BULLETIN 01/05

AIR LIFTINGBAG OPERATIONGUIDE. BasicSafelVPrecautions Equipment Description OperatingInstructions - Applications.

FATAL AND SEVERE RISK PROGRAM

M S I C R A N E S C A L E

FALL PROTECTION GUIDELINE

Workshop Compressors CLASSIC Series

GUIDELINES FOR CONDUCTING HYDROGENATION REACTIONS

Fall Protection- Part 2

1) INTRODUCTION 2) THE UNFAIR ADVANTAGE

Height Safety Lifting Load Control Safety Management

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

Competent Person - Fall Protection Presented by Turner Safety- your instructor is Steve Turner

Limited quantities of compressed gases.

CAISSON SHAFT SYSTEM

RISK ASSESSMENT & DISASTER MANAGEMENT PLAN

Commercial Chain & Fittings

ModelsEZU-15 & EZU-15-R. BISHAMON INDUSTRIES CORPORATION 5651 East Francis Street Ontario, California 91761, USA (909) (800)

RAUBIOXON PLUS Pipe Aerator

Risk Control at United Fire Group

Doc No: FPP CARDINAL SURVEYS COMPANY. Safety Management System. Initial Revision Date: Version Revision No. 02 FALL PROTECTION

User Instructions 1790 Rail Anchor

Unit 24: Applications of Pneumatics and Hydraulics

Subchapter 4. Construction Safety Orders Article 24. Fall Protection. Return to index New query

General Safety and Health Provisions for Construction Self Inspection Checklist

HoverJack. Air Patient Lift. Equipment Manual. From HoverTech International. Issued: June 1,

Prevention of Falls and Working at Heights

MoBiLe CrAnes. surelift. B y W i r e r o p e i n d u s t r i e s. tower CrAnes. port CrAnes

RS5 & RS6 Rescue Sled. Product Manual

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

Premium PowerPoint Presentation. Rigging Review

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

Batch centrifuge basket design.

Height Safety Lifting Load Control

OIL AND GAS INDUSTRY

MODEL UM UNIVERSAL MANIFOLD ASSEMBLY (With or Without Control Valve) 1¼", 1½", 2", 2½", 76.1mm, 3", 4", 6",165.1mm, 8"

Height Safety Lifting Load Control

Webbing. Webbing Treatment. Tear Webbing Energy Absorber. Rope. Sewing

AUSTRALIAN LIFTING CENTRE PTY LTD

Section 16B. Fall Protection. Falls are the second leading cause of death in the workplace. Factors contributing to falling incidents:

MANUAL. Sesame. Thermoplastic Tank Technologies

Team Insert Valve Sample Specification The Insert Valve shall conform to the following:

New Mexico Institute of Mining & Technology. Fall Protection Program

PRESSURE TANKS HANDLING & INSTALLATION INSTRUCTIONS INSTALLATION MANUAL CONTROL VALVES

Ph:

2.2. Anchorage Point A secure point of attachment for Lifelines, lanyards or deceleration devices.

Rubber Lining, Conveyors & Ceramics

29 SERIES - SAFETY VALVE

KM/31000 (Stainless steel end plates) Air bellows, single acting

Pressure & Flame Protection

TECHNICAL DATA. Q = C v P S

VTL VFL VCL. Low Profile Series V RIGGING & ASSEMBLY INSTRUCTIONS

SAFETY/RISK/HAZARD ASSESSMENT

Testing Procedures of Watertight Compartments

Imhoff Custom Services Inc.

Stop the Drop. Fall Protection for Tools. Protecting workers from hazards that can result in personal injury, equipment damage and tool loss.

Holing Underground An

Tribomatic II Powder Pump

Fall Protection Guidelines. Individual Unit Function: Safety Procedure No.: SOP-0111 Page: 1 of 13. Preparer: Owner: Approver: Safety Safety Safety

Fall Protection Program

AUTOMATIC HOSE TEST UNIT, TYPE SPU

Title- Fall Protection Effective Date: 03 Jan 14 Revision-0

II-28 STOKES BASKET OPERATIONS

FXT. FXT Cooling Tower RIGGING & ASSEMBLY INSTRUCTIONS

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

TECHNICAL DATA. Q= Cv S

2.0 Dates and Times Tests to be carried out starting Monday 28 Nov for completion Friday 2 Dec.

RB 80 HYDRAULIC PROP RISK ASSESSMENT

CAST IRON SAFETY VALVE TYPE 6301

WELCOME to CAUx Local India 2018

Fall Protection Resource Guide P AGE 1

Appointed person Note: It is recommended that you read the Supporting Information page before you read this factsheet.

Reviewed: New Effective: 5/18/12 Supersedes: New Preparer: Owner: Approver: Team Member, Occupational Safety Industrial Hygiene

Model MTB-ASME Horizontal Bladder Tanks

ISO INTERNATIONAL STANDARD. Cranes and lifting appliances Selection of wire ropes Part 1: General

Transcription:

Use of Overhead Protection Systems (OPS) in Refractory Lined Vessels. Bill Roelofs and Michael Walton Minvent Solutions RefMet P. O. Box 314 P. O. Box 126 Como PRAHRAN, W. A. 6152 Victoria 3181 ABSTRACT In most cases a refractory repair involves dealing with used refractory linings above shoulder height. This paper details a method of personnel protection involving a low pressure inflatable balloon system, installed to prevent the dislodgement and free-fall of in-situ refractories. The technique may also prevent larger scale collapses with higher internal operating air pressure being applied, but in general is designed to protect against the smaller falls from which most injuries result. INTRODUCTION In many refractory structures, interim repairs require entry of personnel to affect these. Often, significant scaffolding is required to allow personnel to reach the work face. Whether in the Steel, Non-ferrous, Cement or other Process industry, vessels of any size will have refractory, other brickwork or concrete at a level above head height. This constitutes an overhead refractory where falls of surface material from walls or roof, during repairs present a safety hazard to those working in that area. This is particularly an issue shortly after cool-down when the surface temperature of the refractory lags that of the general environment. This means that the thermal contraction of the refractory has not been completed, and falls or spalling of material from the cooling surfaces is still likely. This system, originally developed for underground mining to use in shafts, ore/waste passes, bins and chutes, has now been adapted for use in minerals and petrochemical process vessels. This has been called the Overhead Protection System or OPS. SAFETY PROTOCOLS In the last decade or so, there have been two fatalities, and numerous other incidents involving overhead refractories or falls of objects within such process vessels under repair. The first of these, in 1997, led to a major revision in safety procedures relating to overhead refractories, with the Company involved developing more formal protocols for use in these situations. These, or similar protocols, are now the industry norm.

The general accepted approach to industrial safety hazards can be summarised in figure 1 below. Figure 1: Safety hierarchy of actions. In this hierarchy, the best method is not to invoke the hazard at all, or not to have personnel enter the area. This is quite often not a practical option. The next implies doing the job a different way, again not often practical. The third heading suggests imposing other engineering solutions to allow the job to be done, such as scaffolding protection etc. When faced with overhead refractories, the industry has taken the general approach of dealing with the issue by either demolition ( level 1) or protection (level 3). It is in the latter where OPS applies. CONSTRUCTION The OPS balloon is constructed from heavy duty PVC and PVC composites fabrics. The OPS is fully welded with all anchor and lifting/securing points attached to the inside of the fabric, shaped for the specific application, and welded together. When completed, the constructed shape has a nominal tensile strength of 3500 N/mm 2 (350 Kg per 50mm strip), puncture resistance of 1150 N and burst strength of 2950 N.

Coefficient properties at an internal air pressure of 1.5KPa will generate 250kg of positive pressure per square metre against the walls. A typical calculation is shown below as an example 1. Example, Coefficient calculated force of an OPS Coefficient/frictional resistance for OPS. Coefficient of static friction for the PVC is 0.8 The calculated force at 1.5Kpa internal OPS air pressure is 250 Kg/m². e.g. a Vessel (Quench Tower): 4.0m diameter x 4.0m high, sidewall only : 0.8(50.272 x 250) = 10054.445kg or 10.05 tonne. Additional frictional properties (positive pressure) from top panel contact to the roof area of the vessel have not been included. Additional roof properties: 0.8(12.568 x 250) = 502.72 or 0.5 tonne Thus total wall and roof contact properties equivalent to 10.55 tonne for this example. MANUFACTURE All inflatables are fully welded with a 50mm wide weld for each seam, the industry standard for this type of welding is 25mm to 40mm. The fabric is not stitched, as this creates a perforated tear line and also creates leakage. PVC and PVC composite fabrics have a density range in GSM (grams per square metre) from 900 to 1500, with operating temperatures of -30 to +70 for PVC and -30 to +100 for PVC composite. Each roll of fabric has a section cut out for quality control testing to ensure that the specification parameters are being maintained. Tests for coating to scrim adhesion, coating to coating adhesion, scrim elongation, tear strength; fabric burst strength and puncture resistance are also conducted. All webbing /slings and internal bulge restraint straps are rated and tested. The webbing and anchor points are rated for a minimum of 2 tonne. The inflation system is custom designed with a moulded Venturi inflator. The venture delivers 30 times the volume of introduced compressed air. Example: a 200 m³ unit can be inflated in less than 5 minutes. All finished systems are pressure tested and leakage tested prior to dispatch. For refractory systems where higher temperatures usually exist, an internal air purge is available; this assists with maintaining acceptable air temperatures within the OPS. Several types of materials are available with temperature ranges up to 100ºC. One such material is detailed below in table 1. 1 Reference Fishbane et al (1993)

Table 1: Typical material properties. The OPS may be constructed in natural form (e.g. with bulges each end, to suit brick domes etc), or constructed with internal bulge restrainers, as pictured below in figure 1, to form flatter ends to mitigate and/or control contact pressure.

Figure 1: Large OPS with bulge restrainers to lessen top/bottom extension. This type of bulge restraint is sometimes required when the roof may be compromised with internal upward pressure being applied, or when more working height is required underneath the OPS. This system also provides opportunity to inspect the roof from the top of the OPS if required. INSTALLATION Once completed, the balloon is generally installed with a crane or winch depending on size and circumstance, as the package can weigh up to 800kg. Large balloons can be laid out on custom designed trolleys or skids if access is through a small or restricted opening. It is usual for the balloon to be lifted or lowered by crane into its required position, then inflated in situ. Removal is the reverse procedure.

Figure 2: Large OPS undergoing inflation trials at factory in W. A. OPERATION The OPS is operated with pressures in the range 0-1kPa (to 5 PSI) depending on application. The system can be operated at higher pressures if circumstances require it to be so, (Over pressure tests have shown that these systems can be run at 5psi if required). The pressure is sufficient to gain intimate contact with the wall and roof surfaces, and this is maintained by an air delivery system, which can be plant air or (preferably) a mobile compressor with a pressure regulator. This pressure is also sufficient to hold it to a vertical wall without assistance from the crane (self suspend). The position of the OPS can be adjusted easily by taking the weight on a crane or winch once more, releasing the pressure, thus deflating the balloon, and simply repositioning and re-inflating.

Most OPS systems are designed as material freefall eliminators and not post incident systems such as nets and scaffolding which catch the falling material rather than prevent it from falling in the first instance. Full contact is the preferred installation methodology. The OPS system is generally not designed to protect from a major fall from a roof or upper wall, rather from small to medium fragments which often become loose from a refractory structure on cooling. These may be pieces of say up to 2-3kg, spalled by the cooling process, which occasionally fall when work below starts, dislodged by work activities, such as vibration of jackhammers and the like. With the OPS in position, these will be restrained until the OPS is removed To mitigate any potential free-fall, the OPS must be in contact with the relevant walls or roof. Major falls may also be prevented by this full contact method when internal air pressure of the OPS is adjusted to the required weight bearing setting. Where situation occur that the OPS is not in contact with the roof for varying reasons, an impact cover for the top of the OPS can be provided. The OPS operates on a continuous air trickle feed system through the Venturi, this mitigates any air leakage that may occur from cuts, holes and leakage from fittings. The Venturi simply replaces any lost air as and when required whilst ensuring optimum operating pressures are maintained. The Venturi also performs as an over-pressure valve, OPS systems also have comprehensive point of activity Audible/Visual alarm systems that provide warning for conditions such as mains power loss, OPS low & high pressure, Low pressure is generally the result of lack of air supply, or air loss due to damage such as cuts and holes, high pressure is generally the result of incorrect setting, to much air supply to the Venturi or top/side deforming of the OPS due to loading from debris. Each of these occurrences will result in the activation of the Audible and Visual alarm. APPLICATIONS To date, these systems have been applied to vessels/areas such as, but not limited to: Flash smelter reaction shafts. Fluid bed roaster domes and freeboard zones. Cement pre-calcination shafts. Acid plant towers. Combustors. Quench towers. Off-Gas Ducts. Venturi driers and cyclones. Scrubbers and cross-overs. The figure below shows an actual installation of an OPS in a Flash Furnace reaction shaft.

Figure 3: OPS installed/inflated in reaction shaft of Flash smelter ACKNOWLEDGEMENTS The authors wish to thank the management of RefMet and Minvent Solutions for permission to publish this paper.