Central scientific research automobile and automotive engine institute

Similar documents
COOMET TECHNICAL COMMITTEE 1.8 PHYSICAL CHEMISTRY

COOMET TECHNICAL COMMITTEE 1.8 PHYSICAL CHEMISTRY. CООМЕТ project 576/RU/12

29th Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

ENVIRONMENTAL AND POLLUTANTS GAS ANALYZERS

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Thermo Scientific Model 146i Principle of Operation

STD-3-V1M4_1.7.1_AND_ /15/2015 page 1 of 6. TNI Standard. EL-V1M4 Sections and September 2015

LINEAR TRANSFORMATION APPLIED TO THE CALIBRATION OF ANALYTES IN VARIOUS MATRICES USING A TOTAL HYDROCARBON (THC) ANALYZER

This test shall be carried out on all vehicles equipped with open type traction batteries.

AGILENT TURBOMOLECULAR PUMPS MEASUREMENT METHODOLOGY

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Protocol Gas Verification For Compressed Gas Cylinders Containing Either SO 2, NO or CO. Quality Assurance Plan/Standard Operating Procedure

Gas Mixture Two Components. Gas Mixtures Two Components

The Gold Standard in Calibration Mixtures

Maximum precision for quantifiable success.

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:

Title: Standard Operating Procedure for Dasibi Model 5008 Gas Dilution Calibrator

Vehicle and Engine Emissions Testing

Continuous Gas Analysis In situ laser gas analyzers TÜV and MCERTS add-on for LDS 6 operating instructions Compact Operating Instructions

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

General European OMCL Network (GEON) QUALITY MANAGEMENT DOCUMENT

Supersedes: The copy of this document located on Measurement Canada s website is considered to be the controlled copy.

Final Report of APMP.QM-K46 Ammonia in Nitrogen at 30 µmol/mol Level

METHOD 21 - DETERMINATION OF VOLATILE ORGANIC COMPOUND LEAKS. 1.2 Scope. This method is applicable for the

Title: Standard Operating Procedure for R&R Environmental Devices Model MFC201 Gas Dilution Calibrator

Gas Diluter Portable Gas Dilution System User s Manual

CHAPTER 16 %UHDWKLQJ*DV0L[LQJ3URFHGXUHV

Gas mixtures. Individual solutions specifically for your application

Chapter Pipette service & maintenance. Pipette specifications according to ISO Repair in the lab or return for service?

Calibration of a GC955

THE FUNDAMENTALS OF THE AIR SAMPLER CALIBRATION-VERIFICATION PROCESS

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

Mr Roger Wood Measurement & Process Group (M&P) Network Strategy National Grid Gas plc Brick Kiln Street Hinckley Leicestershire LE10 0NA

Impact of imperfect sealing on the flow measurement of natural gas by orifice plates

APPENDIX C. 40 CFR PART 60 App. B SPEC. 1-4, 6

OIML R 143 RECOMMENDATION. Edition 2009 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

METROLOGICAL ASSURENCE OF O3, CO2, CH4 AND CO CONTROL IN ATMOSPHERE

Particularly with regard to CHAPTER 5 MEASURES TO BE TAKEN AGAINST AIR POLLUTION CAUSED BY TWO OR THREE- WHEEL MOTOR VEHICLES

(NIST Special Publication )

Vaisala Pressure, RH & Temp. Transmitter. The instrument was operational upon receipt. The instrument was adjusted and calibrated.

METHOD 3A - DETERMINATION OF OXYGEN AND CARBON DIOXIDE CONCENTRATIONS IN EMISSIONS FROM STATIONARY SOURCES (INSTRUMENTAL ANALYZER PROCEDURE)

INFLUENCE OF MEASURING PROCESS AUTOMATION ON UNCERTAINTY OF MASS STANDARD AND WEIGHTS CALIBRATION.

VIC offers a variety of Calibrated Gas Leaks

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES

Quality Control of Pulmonary Diagnostic Systems

APPLICATION NOTE. GC Integrated Permeation Device

ASTM WK Standard Test Method for Dissolved Gases. Anne Jurek Applications Chemist

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

MCQ Gas Blender 100 Series 3 Channels Gas Mixer

Application Note AN-107

Title: Standard Operating Procedure for Elemental and Organic Carbon (EC and OC) using Non-Dispersive Infrared Detection (NDIR)

A Depletion Compensated Wet Bath Simulator For Calibrating Evidential Breath Alcohol Analyzers

Certification of AMS acc. EN 15267, Part 3 - Overview and First Experience -

CALIBRATION. empanelled laboratories following standard procedures and using certified reference standards.

Protocol Gas Verification Program (PGVP)

Gases and welding distributors continue

International comparison CCQM-K82: Methane in Air at Ambient level ( ) nmol/mol. (Final report)

CORESTA RECOMMENDED METHOD N 6

EasyLine Continuous Gas Analyzers. So smart, they re simple

Field verification of on-line HC dew point measurements

Organisation Internationale de Métrologie Légale

INTERNATIONAL STANDARD

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

OMCL Network of the Council of Europe QUALITY ASSURANCE DOCUMENT

Air Monitoring Directive Chapter 7: Calibration

Flare Gas Composition Analysis and QA/QC Lessons Learned and Lessons Lost SPECTRUM ENVIRONMENTAL SOLUTIONS, LLC 1

Organic Elemental Analysis Series II CHNS/O Elemental Analyzer. proven performance. reliable results

Gas Metrology. SI-traceable: Primary Reference Materials Certified Reference Materials Calibrated Gas Mixtures Interlaboratory Comparisons

Organic Elemental Analysis Series II Nitrogen Analyzer. proven performance. reliable results

PERFORMANCE SPECIFICATION PROPELLANT, HYDROGEN

HiQ Specialty Gases and Specialty Equipment. Precision matters. In everything we do.

6200E Installation Requirements

Elimination of Percent Level H 2 S Calibration Gas from Flare Gas Monitoring Systems Measuring Total Sulfur, H 2 S and BTU.

Your local gas generation partner. Precision series Modular gas generation solution for GC.

NMISA New Gas Flow Calibration Facility

Generating Calibration Gas Standards

3 HiQ Specialty Gases and Specialty Equipment. Precision matters in everything we do

Comparison APMP.QM-S2.1 Oxygen in nitrogen at atmospheric level

THE PRESSURE SIGNAL CALIBRATION TECHNOLOGY OF THE COMPREHENSIVE TEST

Info Counting chamber (haemacytometer)

Title: Standard Operating Procedure for Sabio 2010 and 4010 Dilution Calibrator

Air Quality 2b - PFGC/FID Analysis of Benzene and Toluene in Automobile Emissions

METHOD 204F--VOLATILE ORGANIC COMPOUNDS CONTENT IN LIQUID INPUT STREAM (DISTILLATION APPROACH) 1.1 Applicability. This procedure is applicable for

Technical Support Note

extraction of EG and DEG from the matrix. However, the addition of all diluent at once resulted in poor recoveries.

Improved Reliability in Natural Gas Energy Measurement with the Revised ISO Standard. Gerard Nieuwenkamp - VSL

TECHNICAL MANUAL CALIBRATION INSTRUCTIONS FUEL PRESSURIZING & DUMP VALVE TEST STAND 1TL

OIML R 16-1 RECOMMENDATION. Edition 2002 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION. Non-invasive mechanical sphygmomanometers

PRESSURE TRANSDUCERS WITH UNIFIED (4-20) ma OR (10-50) ma OUTPUT SIGNAL

WADA Technical Document TD2014EAAS. Endogenous Anabolic Androgenic Steroids Measurement and Reporting

Traceability and Evidential Breath Analyser

Standard Operating Procedure

1. Compute the TWA for the following respirable dust exposures:

Elimination of Oil Residual inside the Copper Pipe Using Ladder Technique

How to evaluate pressure measurement specifications

Lab 1c Isentropic Blow-down Process and Discharge Coefficient

PROTOCOL FOR COMPRESSED AIR PROFICIENCY TESTING (CAPT) PROGRAM SAMPLE ANALYSIS

Measurements. Metric System

Automated Determination of Dissolved Gases in Water Anne Jurek. Abstract: Discussion:

Transcription:

Central scientific research automobile and automotive engine institute

The next mandatory requirements for gas analytical equipment act both in Russian Federation and countries of Customs Union (Belarus, Kazakhstan, Kyrgyzstan, Armenia): all variety of measuring tools (MT) used in the test procedure should be in the list of State Register of Measuring Instruments of the Russian Federation and the countries of the Customs Union; all variety of MT used in the test procedure must be verified by the state metrological service, which, using high-precision equipment and certified verification working mixtures, checks the main operating characteristics of the instruments and the limits of measurement errors which shall be at the required tolerances. In practice, there is a need for additional calibration of analytical equipment, especially when the MT are used in extreme conditions. For a example - carrying out of quantitative measurements of pollutants on board of test vehicles during the road test, when it is possible to violation of gas analyzer s settings during on-line analysis due to possible disruption of the horizontal installation of equipment, the impact of vibration and speed loads and other factors of instability. In these cases, an additional laboratory calibration of the MT is carried out twice - before and after the test.

gas mixture generator mod. 655 GR 05 (dynamic divider) used for the preparation of binary calibration gas mixtures of lower concentration with a dilution factor K from 20 to 2500 within the permissible relative deviation of the dilution ratio from the nominal value within ± 2% calibration gas mixtures (CGS) in a gas cylinder: (NO in nitrogen, NO 2 in nitrogen, CO in nitrogen) with blending error ± 5% working gas in a gas cylinder (synthetic air, purity for chromatography, 20% - O 2 is, N 2 is the rest)

3-4 values of the of CGM s concentration (NO, CO NO 2 in N 2 ) calculate with using of ratio of valve numbers of divider and dividing coefficient Kdil : Kdil = Ccalc / CCGM, (1) where Kdil dividing coefficient, Ccalc specified content of diluted CGM, mg/m 3, CCGM concentration of CGM in gas cylinder, mg/m 3 The concentration CCGM is fed to the input of the divider and further Ccalc prepared by the divider according to the formula (1) is fed from the output channel of the divider to the input of the gas analyzer. Readings of gas analyzer are compared with values of Ccalc. Difference between Ccalc and the gas analyzer s readings (the basic relative error, β), should not be exceed 25%. In practice, the meaning of β are at the level of 3-8%. One of the results of inter laboratory calibration of working MT participating before and after the test is given at the table on the next slide.

In-lab calibration date 1/02/2018 Date of mandatory verification Gas analyzer mod R 310A (NO, NO2) N 72-4-01 Gas analyser mod. OPTOGAS 500-4-CO (CO), N 3/09/2017 up to 3/09/2018 Gas diluter, mod. 645 GR-03M N 28/06/2017 up to 28/06/2018 Concentration of gas mixture (CGM), NO/N 2, ppm 51,9 03/2017 Concentration of gas mixture (CGM), NO 2 /N 2, ppm 51,0 03/2017 Concentration of gas mixture (CGM), CO/N 2, ppm 85,0 06/2017

Dynamic divider (gas mixture generator) mod.655 GR05 The gas cylinder with working gas (synthetic air) Gas cylinders with calibration gas mixture of calibrated components NO, NO2, CO in nitrogen

In lab calibration data of gas analyzers before start and after finish of test In lab verification of NO 2 0.813 0.810 0.416 0.409 0.201 0.203 0.106 0.104 Specified concentration, mg/m 3 0.812 0.406 0.206 0.104 Valve, for dilution, 8 5,6 3,5 2,4 Measured concentration, 0.814 0.828 0.392 0.396 0.200 0.203 0.098 0.100 mg/m 3 Basic relative error, β, % 0.2 1.9 3.4 2.5 2.9 1.4 5.8 3.8 Checks before and after test before after before after before after before after In lab verification of NO Specified concentration, mg/m 3 0.814 0.396 0.201 0.109 Valve for dilution, 7,8 5,7 4,6 5 Measured concentration, mg/m 3 Basic relative error, β, % 0.01 0.05 2.5 2.3 0 0.9 2.7 4.5 Checks before and after test before after before after before after before after

In lab calibration data of gas analyzers before start and after finish of test In-lab verification of СО Specified concentration, mg/m 3 0.51 1.02 1.98 5.24 Valve for dilution, 4,7 6,8 7,9 8,9,10 Measured concentration, mg/m 3 0.5 0.55 1.0 1.08 2.2 2.1 6.0 5.80 Basic relative error, β/ % 1.9 7.7 2.0 5.9 11 5.7 14.5 10.6 Checks before and after test before after before after before after before after Basic relative error, β, % = Specified concentration, mg/m 3 - Measured concentration, mg/m 3 Specified concentration, mg/m 3

When the results of inter laboratory calibration before the start and after finishing of testing have been exceed the required basic relative error β, gas analyzers settings are checked and after that the calibration procedure should be repeated. The general rule for calibration procedure - the values of β in all cases should not exceed the required values (± 25%).

Central scientific research automobile and automotive engine institute