Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Similar documents
Standard Operating and Maintenance Instructions for Pumping System Model PS-150

Air Operated Hydraulic Pumping Systems to 50,000 psi

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

Air Amplifiers & SYSTEMS

OPERATION MANUAL NTF-15

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times

Pneumatic Powered - Plunger Pumps

OPERATION MANUAL NTF-60 Plus

CASH VALVE TYPE KP BACK PRESSURE VALVES

PRO-50 Instrument Supply Regulator

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

Section 3000 CONVEYOR CHAIN LUBRICATION SCHEMATIC...39 AIR OPERATED SPRAY DISPENSERS - CENTRAL ACRYLIC RESERVOIR Section 3000 Index

HANDBOOK. Squeeze Off Unit SOU 400. Please refer any queries to:

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10

AIR DRIVEN. Gas Boosters & SYSTEMS. Accepting VISA, MasterCard and American Express

Inert Air (N2) Systems Manual

TEST BENCH FOR SAFETY VALVES

Pressure Dump Valve Service Kit for Series 2300 Units

Suggested Installation & Operating Instructions for Sidewinder Pumps

WW-730. Pressure Sustaining/Relief Control Valve

Model Air Caddy Orig TABLE OF CONTENTS

WW-720. Pressure Reducing Control Valve

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

Plant, components and devices for very high and high pressures (7000 bar and over)

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

High Pressure Equipment Medium Pressure Valves, Fittings and Tubing

HNP-021 Oil Purifier. Description. Specifications. Features. Contact Us:

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

Operation Manual Piston Sensed Gas Pressure Regulators

Air Eliminators and Combination Air Eliminators Strainers

WW-720. Pressure Reducing Control Valve

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER

MANUAL BE SERIES Test Benches

Series 58 SAFETY VALVES 312

IFP C175-* REMOTE CONTROL RELIEF VALVE

High Pressure Equipment Taper Seal Valves, Fittings and Tubing

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

Hip Air Operated Valves

Tentec. Instruction Document. Mini Air Driven Pump Unit Model: HTT.627X Series. Part Identifier

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

ALF400 to 900, ALT-5/-9

High Pressure Equipment Medium Pressure Valves, Fittings and Tubing

1800CPB2 Service Regulators

Model Series 62 Constant Differential Relay

TITAN FLOW CONTROL, INC.

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

Operation & Maintenance Manual Place this manual with valve or person responsible for maintenance of the valve

TECHNICAL DATA. Q= Cv S

553 Series.

Pressure Dump Valve Service Kit for Series 3000 Units

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

HANDBOOK. Squeeze Off Unit SOU 250. Please refer any queries to:

TECHNICAL DATA. Q = C v P S

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y

CFC2. Float Control For Closed Tanks MODEL. Specifications. Dimensions (In Inches) Reservoir Connection 1" NPT (Typ. Both Ends 2 Places)

KECKLEY INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS TYPE NO. 7 FLOAT VALVE

SC HYDRAULIC ENGINEERING CORPORATION

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve

MEGR-1912 Instruction Manual

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

Direct Operated Precision Regulator Modular Style. Standard Specifications

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

SAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions. IMPORTANT NOTICE

OWNER S TECHNICAL MANUAL

HP/UHP Spring-Loaded Regulator

V43 Pressure Actuated Water Regulating Valve

High Pressure Equipment Pressure Vessels and Reactors Index

All information correct as of 25 th September 2013 and subject to change without notice. 6 inch HURRICANE modular dredge equipment operations manual.

KJ1000 Operating Instructions & Parts Manual NSN

Pressure Regulator B-95

OPERATING AND MAINTENANCE MANUAL

Product Sheet Spraymist Unit

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use

ECS Protector Nitrogen Generator PGEN-30 (PGEN-30E)

GREIG FILTERS, INC. OPERATION MANUAL

!!!! SERVICE MANUAL PRESSURE POT 2 GALLON. Service Manual: LT Washington St 931 Progress Ave., #7

1800CPB2 Service Regulators Maximum Inlet Pressure 125 PSIG

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Instructions for Installation, Operation, Care and Maintenance

GROUTEC SCOTT VICKERS. Grouting Equipment

Product Manual. Description. Specifications. CVS Type 1301F and CVS Type 1301G Regulator. Introduction

Beamex PG PRESSURE GENERATORS. Beamex PGM PGV PGC PGHH PGPH PGL

for Building facilities Industrial facilities etc.,multipurpose Pilot operated type(high capacity)

ACCU-PULSE Installation and Operation Instructions

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

KJ4000 Operating Instructions & Parts Manual NSN

2.5 & 5.0 GALLON PRESSURE TANKS

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

Transcription:

Standard Operating and Maintenance Instructions for Pumping System Model PS-90 High Pressure Equipment Company 2955 West 17th Street, Suite 6 PO Box 8248 Erie, PA 16505 USA 814-838-2028 (phone) 814-838-6075 (fax) www.highpressure.com

Standard Operating and Maintenance Instructions for Pumping Systems Models PS-90: Description: High pressure air operated hydraulic pumping systems are complete, self-contained units and are ready to operate. Just hook up standard shop air supply (maximum 100 psi) to connection supplied on the side of the console. Discharge capacities range from 2 cubic inches per minute to 64 cubic inches per minute depending on the model. Standard Features: System includes hydraulic oil reservoir, oil filter, air operated hydraulic pump, pressure gauge, panel mounted high pressure valves, safety head assembly, panel mounted air regulator and gauge, air line filter, and lubricator. All components are enclosed in a steel console with only the back exposed. Dimensions of standard systems are 26 in wide, 24 in deep, and 40 in high. Safety Features: The system includes a safety head and rupture disc located within the cabinet in order to provide maximum safety to the operator. The disc has been installed at the factory and is rated slightly higher than the maximum working pressure of the unit. In the event the pressure is permitted to exceed the maximum working pressure, the disc will rupture before any damage of the gauge or other components occurs. The safety head is machined with a pipe thread on the exhaust. A pipe connection may be run from this opening to any convenient vent. This will eliminate any oil spillage within the cabinet in the event the disc becomes ruptured. High Pressure Equipment Company. Erie, PA Page 2

System Capabilities: The output pressure is predetermined by adjustment to the air regulator setting. Output pressure is maintained constantly and pump compensates for pressure drops or losses. Hydraulic input is gravity fed, however, if pump is used alone, the feed can be pressurized to the limit of the pump. Within the pump the large diameter air piston drives a smaller piston to provide fluid flow at high pressure. Air consumption will be approximately 56 cfm of free air at 100 psi input. Reservoir capacity is 4 gallons, do not pressurize. Standard Pumping System Specifications High Pressure Equipment Company. Erie, PA Page 3

Installation: The only connections required for installation of the system are an air supply and connection of the system to the pressure vessel or unit which is to be pressurized. The air supply line is connected directly to the side of the cabinet and is for ½ in NPT pipe. A larger air supply line is recommended if the system is quite a distance from the source of air. The high pressure outlet connection is for ¼ in OD coned and threaded tubing (HF4 connection). The reservoir is built directly into the cabinet and should be filled with a suitable fluid before operation. Most any low viscosity petroleum base hydraulic oil may be used. Other fluids including water may be used on occasion if it becomes necessary; however, water will decrease the packing life of the pump and should not be used if avoidable. Operating Instructions: 1. Set the air regulator at the desired pressure accordance with the regulator setting chart. Approximate settings are 95 psi for the low pressure feed pump (output 15,000 psi) and 95 psi for the pressurizing pump (output 90,000 psi) 2. Close the "Vent Valve. 3. Open the "High Pressure Outlet Valve". 4. Open the "Air Supply Valve". The system will now begin to build up pressure until the set pressure limit is reached and then will automatically stop. Should there be any pressure loss due to temperature, compaction of the materials being pressurized, or leakage in the item being pressurized, the pump will automatically start up and compensate for the pressure loss. Venting the System: To vent the pressure from the system simply shut off the "Air Inlet Valve" and open the "Vent Valve" and all of the pressurized fluid will return to the reservoir. Pressure may be vented rapidly or slowly by simply controlling the amount the vent valve is opened. It is not necessary to close the high pressure valves extremely tight for maximum shutoff; this will tend to damage the valve seat and the stem. High Pressure Equipment Company. Erie, PA Page 4

Maintenance: The air line is equipped with a filter and lubricator. The air filter is provided to filter water from the air supply. Depending upon the amount of water in the air supply, the filter bowl will fill up over a period of time. This is easily drained by opening the small drain petcock on the bottom of the bowl and allowing the water to drain into a container. The fluid within the reservoir should be kept clean in order to provide maximum life of the pump. When this fluid becomes excessively dirty, it is easily drained through the drain plug located at the bottom of the reservoir. A filter is provided between the reservoir and the pump. It is recommended that the disposable cartridge be removed and replaced should it become clogged with an excess of dirt. The valve between the reservoir and filter should be closed before removing the filter. Trouble Shooting: The pump is running but will not develop pressure: 1. If the system has just been shipped, moved to a new location, or repairs have been made within the hydraulic lines, an "air lock" may have developed. A connection on the inlet side of the pump should be broken enough to determine whether or not the pump is receiving oil from the reservoir. If so, a connection on the outlet side of the pump should be broken slightly. With the pump operating (set the regulator so that the pump is operating slowly) determine as to whether there is a flow through the lines. This will usually clear the "air lock" and the connection can be retightened. 2. If the pump will not develop pressure and there does not appear to be an "air lock." The check valves on the inlet and outlet side of the pump should be cleaned or replaced. Spare parts or further information about your pumping system may be obtained direct from the HiP factory. Parts are generally stocked for immediate delivery. High Pressure Equipment Company. Erie, PA Page 5