DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATA SHEET N 186 N 186.1.2 ST.12 E Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its central point by means of an eccentric. In this way the medium is transferred using automatic valves. The KNF double diaphragm system for increased safety. A second diaphragm is located underneath the working diaphragm. If gas should leak at the working diaphragm, it will still remain inside the pump space. Thanks to the KNF modular system, the parts used to transfer the gases can be made from materials with varying degrees of durability. The customer has a choice of pump drives ranging from a selection of motors models. Please contact us for further details. Explosion protection pumps in ATEX on request. Features Pure transfer No contaation of the media due to oil-free operation Maintenance-free Corrosion resistant models High level of gas tightness Following leakage rates are available:.9 corresponds to < 6 x 10-3 mbar l/s SP.13 corresponds to < 6 x 10-6 mbar l/s ST.13 corresponds to < 6 x 10-5 mbar l/s SP.12 corresponds to < 6 x 10-6 mbar l/s Long product life Cool running motor even when in constant use Areas of use These pumps are required especially in the fields of analytical technology, chemistry industry and production technology as well as research. The pumps transfer, compress or draw highly aggressive gases and vapors, take samples as sample gas pumps (or liquid samples using ), evacuate vessels or transfer aggressive gases as process gas pumps in chemical facilities. Pumps with the KNF double diaphragm system are employed for expensive, toxic and dangerous gases. Double diaphragm pumps in ATEX for potentially explosive atmospheres on request. (l/) (mbar absolute) atm. Pressure () N 186.3 AP.9 E 23 15 0.5 25 N 186.3 SP.9 E 23 15 0.5 29.5 N 186.3 SP.13 E 23 15 0.5 29.5 N 186.3 SP.12 E 23 15 0.5 30.5 N 186.3 ST.9 E 21 25 0.5 29.5 N 186.3 ST.13 E 21 25 0.5 29.5 N 186.1.2 AP.9 E 42 120 7 25 N 186.1.2 SP.9 E 42 120 7 29.5 N 186.1.2 SP.13 E 42 120 7 29.5 N 186.1.2 SP.12 E 42 120 3 30.5 N 186.1.2 ST.9 E 35 130 7 29.5 N 186.1.2 ST.13 E 35 130 7 29.5 Weight (kg)
N 186.1.2.9/.13 E at atm. (l/) () N 186.1.2 AP.9 E 42 ± 10 % 7 120 N 186.1.2 SP.9 E 42 ± 10 % 7 120 N 186.1.2 SP.13 E 42 ± 10 % 7 120 N 186.1.2 ST.9 E 35 ± 10 % 7 130 N 186.1.2 ST.13 E 35 ± 10 % 7 130 () Pump head Diaphragm Valves/Sealing N 186.1.2 AP.9 E Aluum EPDM Stainless steel N 186.1.2 SP.9 E Stainless steel EPDM Stainless steel N 186.1.2 SP.13 E Stainless steel EPDM Stainless steel N 186.1.2 ST.9 E Stainless steel PTFE-coated Stainless steel N 186.1.2 ST.13 E Stainless steel PTFE-coated Stainless steel Voltage (V) 230 3~ 230/400 Power P1 (W) 550 310 lmax (A) 4.5 3.3/1.9 N 186.1.2.9 E N186.1.2.13 E N 186.1.2 _P.9 E N 186.1.2 _P.13 E FLOW CAPACITY N 186.1.2 ST.9 E N 186.1.2 ST.13 E FLOW CAPACITY atm. atm.
N 186.1.2 SP.12 E at atm. (l/) () () N 186.1.2 SP.12 E 42 ± 10 % 3 120 Pump head Diaphragm Valves/Sealing N 186.1.2 SP.12 E Stainless steel EPDM Stainless steel Voltage (V) 230 3~ 230/400 Power P1 (W) 610 310 lmax (A) 5.3 3.3/1.9 N 186.1.2 SP.12 E N 186.1.2 SP.12 E FLOW CAPACITY atm.
N 186.3.9/.13 E at atm. (l/) () N 186.3 AP.9 E 23 ± 10 % 0.5 15 N 186.3 SP.9 E 23 ± 10 % 0.5 15 N 186.3 SP.13 E 23 ± 10 % 0.5 15 N 186.3 ST.9 E 21 ± 10 % 0.5 25 N 186.3 ST.13 E 21 ± 10 % 0.5 25 () Pump head Diaphragm Valves/Sealing N 186.3 AP.9 E Aluum EPDM Edelstahl N 186.3 SP.9 E Stainless steel EPDM Stainless steel N 186.3 SP.13 E Stainless steel EPDM Stainless steel N 186.3 ST.9 E Stainless steel PTFE-coated Stainless steel N 186.3 ST.13 E Stainless steel PTFE-coated Stainless steel Voltage (V) 230 3~ 230 400 Power P1 (W) 470 310 lmax (A) 5.0 3.3/1.9 N 186.3.9 E N 186.3.13 E N 186.3 _P.9 E N 186.3 _ P.13 E FLOW CAPACITY N 186.3 ST.9 E N 186.3 ST.13 E FLOW CAPACITY atm. atm.
N 186.3 SP.12 E at atm. (l/) () () N 186.3 SP.12 E 23 ± 10 % 0.5 15 Pump head Diaphragm Valves/Sealing N 186.3 SP.12 E Stainless steel EPDM Stainless steel Voltage (V) 230 3~ 230 400 Power P1 (W) 470 310 lmax (A) 5.0 3.3/1.9 N 186.3 SP.12 E N 186.3 SP.12 E FLOW CAPACITY atm.
TECHNICAL INFORMATION N 186.1.2.9 E N 186.1.2.13 E PUMP UP TIME FOR 20 LITER VESSEL N 186.1.2 SP.12 E PUMP UP TIME FOR 20 LITER VESSEL N 186.3 PUMP DOWN TIME FOR 20 LITER VESSEL mbar abs N 186.1.2 PUMP DOWN TIME FOR 20 LITER VESSEL mbar abs
HINTS ON FUNCTION AND INSTALLATION Function of KNF diaphragm pumps and compressors An elastic diaphragm is moved up and down by an eccentric (see illustration). On the down-stroke it draws the air or gas being handled through the inlet valve. On the up-stroke the diaphragm forces the medium through the exhaust valve and out of the head. The compression chamber is hermetically separated from the drive mechanism by the diaphragm. The pumps transfer, evacuate and compress completely oil-free. Hints on installation and operation Range of use: Transferring air and gases at temperatures between +5 C and +40 C. Permissible ambient temperature: between +5 C and +40 C. Please check the compatibility of the materials of the pump head, diaphragm and valves with the medium. The KNF product line contains pumps suitable for pumping aggressive gases and vapors please contact us. The standard pumps are not suitable for use in areas where there is a risk of explosion. In these cases there are other products in the KNF program please ask us for details. The pumps are not designed to start against or ; when a pump is switched on the in the suction and lines must be atmospheric. Pumps that start against or are available on request. To prevent the maximum operating being exceeded, restriction or regulation of the air low should only be carried out in the suction line. Components connected to the pump must be designed to withstand the pneumatic performance of the pump. Install the pump so that suficient supply of cooling air is ensured. Fit the pump at the highest point in the system, so that condensate cannot collect in the head of the pump that prolongs working-life. ACCESSORIES Description Order No. Water cooling.9/.13 303901 Water cooling.12 303902 Foot plate with shock mounts 310102 KNF Neuberger GmbH Alter Weg 3 D 79112 Freiburg Tel. +49 7664 5909 0 Fax +49 7664 5909 99 info@knf.de www.knf.de KNF reserves the right to make technical changes. KNF 08/2018 (Produced in Germany)