IV IV Training Guide

Similar documents
2008T Hemodialysis Machine with CLiC Device Training Guide

Indications for Use: Caution: Note:

Contacts. Quick Start Guide

AQUADEX FLEXFLOW SYSTEM QUICK REFERENCE GUIDE

MANITOBA RENAL PROGRAM

Liberty Handi-Guide. A Patient s Reference to the Most Commonly Asked Questions About the Liberty Cycler

Liberty PDx Cycler Handi-Guide

Liberty Cycler Handi-Guide

Liberty Handi-Guide A Patient s Reference to the Most Commonly Asked Questions About the Liberty Cycler

AQUARIUS Continuous Renal Replacement Therapy with Regional Citrate Anticoagulation (RCA) Competency

AQUARIUS Continuous Renal Replacement Therapy Competency

Quiz for Module 2: Aquarius Training (Rev. 1) Lesson 1: Introduction to Aquarius

Handi-Guide A Patient s Reference to the Most Commonly Asked Questions About the Liberty Select Cycler

HemoCue Hb Procedure Template

Endo-Flush Order # ZUTR30004 OPERATION MANUAL. Zutron Medical, LLC W 98 th St #40-27 Lenexa, KS Phone Fax

STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA

Department of Laboratories St. Louis, MO ISSUE DATE: June 2007 REVISION DATE: July 2010 REVIEWED DATE: May 2017 PRINCIPILE:

WARNING: EXPLOSION HAZARD

Liberty Cycler User s Guide

Liberty Select Cycler User s Guide

Liberty PDx Cycler User s Guide

1020 Industrial Drive, Orlinda, TN fax

MANITOBA RENAL PROGRAM

Astral in AirView: Improving patient care through connectivity. ResMed.com

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

My CoughAssist. A patient guide to CoughAssist T70. Please visit

NanoSight NS300. NanoSight NS300. Operation instructions. Laser Spectroscopy Labs, UCI

Cardiac Output Simulation for Specific Makes of Monitor. Each injection yields in a time-temperature curve whose area represents the cardiac output:

Oxygen Dialflow Meter. Instructions for Use

CRRT with Prismaflex LEADS TO More Flexibility, Ease of Use and Safety

INTERNATIONAL MARKETING. 61, avenue Tony Garnier Lyon France Tel.: 33 (0) Fax: 33 (0)

Astral in AirView: Improving patient care through connectivity. ResMed.com

Prepared By: Lisa McAvoy 28/Nov/17 dd/mmm/yy. Approved By: Veronica Harris-McAllister 30/Nov/17 dd/mmm/yy

Operation and Maintenance of the EPV200 Portable Ventilator

Overview. Front Panel: Keypad and Display

Blood Parameter Monitoring System 550

Pedometer with PC download. Model: FB322 OVERVIEW FRONT VIEW INDEX

Heart/Lung Perfusion Packs INSTRUCTIONS FOR USE

Troubleshooting Guide Aquarius

ECHO MANUAL WARNING. L B A ltim e te rs. ECHO is a trademark of LB Altimeters, Denmark

MASK INTEGRITY TEST ACCESSORY (MITA) MODEL 8120

MP15 Jockey Pump Controller

Scoreboard Operator s Instructions MPC Control

CONTENTS SPECIFICATIONS GENERAL INFORMATION RECOMMENDED USE OPERATING PRINCIPLE TIPS ON TAKING YOUR BLOOD PRESSURE 3-4 BATTERY INSTALLATION

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

UsER manual for Watersens ph -REDOX

Read this first. Zetasizer nano series Self installation and Quick start guide MRK825-02

FAULT CODE TROUBLESHOOTING INDEX

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

CircuFlow Quick Setup Guide

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

Procedure 85 Attaching The Humidifier To The Oxygen Flow Meter Or Regulator. Procedure 86 Administering Oxygen Through A Nasal Cannula

CDI System 500. Blood Parameter Monitoring System. Continuous blood parameter monitoring for improved blood gas management

WARNING FOR YOUR SAFETY

2008T Hemodialysis Machine Operator s Manual

Fingertip Pulse Oximeter

Instruction Manual. Auto Inflate Blood Pressure Monitor

1020 Industrial Drive, Orlinda, TN fax

Experiment B-18 Heart Rate and Coughing

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

955730_1 4/17/18. FlowSense Operator s Guide For Gen2 20/20 SeedSense Displays

Introduction. Table of Contents. Automatic Wrist Blood Pressure Monitor With Voice-Guided Operation. Model No.: BP5K

Module 2: Aquarius Training

ASAHI Neurovascular Guide Wire

EZ-Boom 2010 Automated Application Control System Quick Reference Card INTRODUCTION

TR Electronic Pressure Regulator. User s Manual

with O 2 Controller Instruction Manual

Pulmonary Function I (modified by C. S. Tritt, April 10, 2006) Volumes and Capacities

The NAMIC Dream Kit. Single Operator Control. Reduce Contrast Waste. Less Force to Inject. Compensator * Manifold. How the Compensator Manifold Works:

Navigator 600 Silica analyzers

Oxygen Dialflow Meter. Instructions for Use

User Manual 1 P a g e Rev. V1.6-EN 11/08/2014

QUICK START GUIDE TO DRINKING WATER MONITORING

WELCOME TO THE REVOLUTION

TJF-Q180V Cleaning and Disinfection Checklist

Rev. B. Operating Instructions

OC Panel High Limit Aquastat Kit, Manual Reset p/n

Instructions for Use. OptiLife Nasal Lab Mask

Experiment AMe-1: Small Animal Respiratory Exchange Ratio (RER)

EMS INTER-FACILITY TRANSPORT WITH MECHANICAL VENTILATOR COURSE OBJECTIVES

- Repeat calibration until desired results are reached otherwise set SW2 and SW1-8 open.

RM-80 respiration monitor

BD Cytopeia Fluidic Kit User s Guide

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

Micro Dial-Flowmeter. Instructions for Use

Syringe, Distribution Valve and Infusion Pump Removal/Replacement ATTENTION SYRINGE REPLACEMENT

New product release. Universal Rebreather Monitor (URBM) Single O2 cell and Dual HP package

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

NEULOG OXYGEN LOGGER SENSOR GUIDE

RECONSTITUTION AND ADMINISTRATION INSTRUCTIONS FOR HEALTHCARE PROFESSIONALS. Hereditary Angioedema

User Manual for the Mars Calibration Bench

Oxygen Meter User Manual

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

Instructions for Use

FireHawk M7 Interface Module Software Instructions OPERATION AND INSTRUCTIONS

WATER CONTROL SYSTEM QUICK START

User Manual. Model 3930 Vacuum Assisted Venous Drainage Controller w/ WAGD Suction Flowmeter

Boyle s Law: Pressure-Volume Relationship in Gases

AUTOVENT 4000 VENTILATOR

Transcription:

Training Guide

Indications for Use: The Crit-Line monitor is used to non-invasively measure hematocrit, oxygen saturation and percent change in blood volume. The sensor clip measures hematocrit, percent change in blood volume and oxygen saturation in real time for application in the treatment of dialysis patients with the intended purpose of providing a more effective treatment for both the dialysis patient and the clinician. Based on the data that the monitor provides, the clinician/nurse, under physician direction, intervenes (i.e. increases or decreases the rate at which fluid is removed from the blood) in order to remove the maximum amount of fluid from the dialysis patient without the patient experiencing the common complications of dialysis which include nausea, cramping and vomiting. The Crit-Line blood chamber is a sterile, single use, disposable, optical cuvette designed for use with the Crit-Line sensor clip during acute and chronic hemodialysis therapy to non-invasively measure hematocrit, percent change in blood volume and oxygen saturation. The blood chamber is connected between the arterial bloodline and the dialyzer within the extracorporeal circuit during the hemodialysis treatment. Caution: Federal (US) law restricts these devices to sale by or on the order of a physician. Note: Read the Instructions for Use for safe and proper use of these devices. For a complete description of hazards, contraindications, side effects and precautions, see full package labeling at www.fmcna.com.

Training Guide Introduction The Crit-Line Monitor Training Guide (Guide) is solely for training skilled healthcare professionals in the use of the Crit-Line monitor. This Guide is intended to be used as a companion to the Crit-Line Monitor User s Guide (User s Guide, P/N CL 80050002), which contains detailed instructions for all machine functions. This Guide is designed to be flexible, taking into account the various experiences and skill level of the participants, the number of participants and the amount of time available for training. Similarly, this Guide recommends that participants have the opportunity to use the Crit-Line monitor during a patient dialysis session to enhance the training experience. This hands-on experience may occur at the time of training or over several days depending on the facility, shift schedules, etc., and should be tailored to each facility, participant and situation. Each facility will determine who will participate in the Crit-Line Monitor In-Service Training. It is anticipated that participants will include nurses, patient care technicians (PCTs), and physicians, with nurses being the primary focus of the In-Service Training. 1

Training Prework: In order to ensure that participants have the clinical background needed to interpret the Crit-Line monitor data, all nurses must complete the following online course prior to attending this training: www.crit-linetrainingcourse.com Completion of the prework by other participants (e.g., PCTs) is at the discretion of each facility. Training Resources: In addition to this Guide, the following materials are incorporated into the Crit-Line Monitor In-Service Training: Crit-Line Monitor User s Guide Crit-Line Monitor Participant Workbook (P/N 102778-01) Crit-Line Monitor Reference Guide (P/N 102273-01) Crit-Line Monitor Quickstart Guide (P/N 102272-01) Icons and Descriptions: The following icons are used in this Guide to provide direction and clarity: Icons and Descriptions Instructor explanation and demonstration Facilitation tips and supplemental comments A Warning or caution 2

Training Guide Training Timeline 4-6 Weeks Prior to Training: Schedule participants and communicate pre-work requirements. 4 Weeks Prior to Training: Ensure that the following are available at the facility for training: - Crit-Line monitors, sensor clips and blood chambers - Crit-Line Monitor Training Guide - Crit-Line Monitor User s Guide - Crit-Line Monitor Participant Workbook (one per participant) - Crit-Line Monitor Reference Guide (extra copies for facility) 2 Weeks Prior to Training: Ensure that prework has been accessed and that participants are on track to complete the prework ahead of the scheduled training day. 1 Week Prior to Training: Confirm receipt of training materials Confirm participant attendance Day of Training: Plan to arrive early to ensure that the Crit-Line monitor is available for use and the blood chambers have been located. Training Guide Note This Guide s training is limited to the features and operation of the Crit-Line monitor and does not cover other critical dialysis-related subjects or related clinical theory. Neither this Guide, nor the In-Service Training, are intended to compromise or replace specific policies and procedures of hemodialysis providers or the treatment prescriptions of physicians. Fresenius Renal Technologies and its affiliates make no recommendations and assume no liability for the policies and procedures established in hemodialysis providers clinics for hemodialysis treatments. 3

Training Topics Welcome/getting Started Distribute and introduce the Crit-Line Participant Workbook Introduce the Crit-Line Monitor User s Guide Crit-Line Monitor Overview Monitor features Setup Blood chamber placement Sensor clip Preparation for Treatment Verify accuracy routine Initiation and Termination of Treatment Sensor clip attachment Start run BV alert level O 2 alert level Markers Ending a treatment Printing/downloading treatment results Cleaning Troubleshooting Alarms Review Profiles A, B and C Hands-on Demonstration Facility patient treatment area 4

Training Guide Notes: 5

Getting Started Welcome Participants Ensure that all participants have registered their attendance on the sign-in sheet. Solicit the cooperation of the participants to ensure a good learning experience, including, limiting cell phone usage to breaks only. Set Expectations: Timing of training (approximate length of classroom experience) Timing and process for actual demonstrations o It is recommended that demonstrations begin during a shift change. Depending upon the number of participants, there may need to be several demonstrations in order for everyone to have the opportunity to see the actual Crit-Line monitor in operation. Distribute and Introduce the Participant Workbook Give participants a few minutes to familiarize themselves with the Participant Workbook. Let the participants know that it is their personal workbook to keep and encourage them to take notes for future reference. Introduce the Crit-Line In-Service Training Checklist, located on page 25 in this Guide and in the Participant Workbook and encourage participants to check topics off as they are covered during the training. Introduce the Crit-Line Monitor User s Guide Remind participants that the User s Guide provides a reference for use of the Crit-Line monitor and should be available in the facility at all times. 6

Training Guide Crit-Line Monitor Overview Review the physical features and setup of the Crit-Line system, and point out specific items listed below. Features Sensor clip USB Connector Zigbee Radio (optional) Verification Filter Crit-Line Blood Chamber Power Supply Adapter Power Connection Serial Com 1 Power Switch Power Supply Jack Setup and Power On Attach blood chamber and check position o If demonstrating in the classroom, use sensor clip, blood chamber and dry dialyzer. o If demonstrating on the patient treatment floor, use actual machine. Prime (per unit procedure) 7

Crit-Line Monitor Crit-Line Blood Chamber USB Connection Verification Filter Wireless ZigBee Radio (optional) Sensor Clip 8

Training Guide Mount Bracket Com 2 Com 1 Power Supply Jack Ethernet Ports (not active) Serial Ports (only Com 1 is active) USB Ports (both active) Power Switch 9

Preparation for Treatment Review the steps required to prepare for a patient treatment using the Crit-Line monitor, being sure to point out specific features as detailed below. Crit-Line Monitor Verification Filter The sensor clip features a verification filter unique to each sensor device. The verification filter is used to periodically verify the accuracy of the sensor clip. The sensor verification filter is attached to the sensor clip s USB cable. The sensor clip should be securely attached to the verification filter when it is not in use. When the sensor clip is stored on its verification filter, the Crit-Line monitor automatically verifies the accuracy of the sensor clip prior to entering patient run mode. If the sensor clip is not stored on the Crit-Line verification filter, it must be manually verified at least once per month. 10

Training Guide Verifying the Sensor Clip Verifying Accuracy on the Sensor Selecting the Verify Accuracy button from the Main Menu screen allows the user to perform a manual verification of accuracy on the sensor clip. Note: In most cases, it is not necessary to perform a manual verification. If the sensor clip is placed onto the verification filter, the Crit-Line monitor will automatically perform a verification test once per day, and the date of the most recent successful verification will be displayed below the Verify Accuracy button. Note: The user cannot access the Patient Run Menu screen until a successful verification has taken place. Note: If the verification fails two or more times, the option is given to perform a field calibration. Follow these basic steps to manually verify accuracy: 1. Place sensor clip on verification filter. 1. Hold the sensor clip such that one side is held by the index finger and the other side is held by the thumb. Squeeze the clip to spread the sensor elements apart. 2. Place the sensor clip over the verification filter such that the sensor elements cover the middle portion of the verification filter. 3. Release the sensor clip to allow the sensor elements to sit on the verification filter. 4. Make certain that the sensor clip has locked securely into place on the verification filter by noting the audible and tactile click. 2. Press the Verify Accuracy button. Once the Verify Accuracy button is pressed, the following screen will appear. This screen will remain for approximately ten seconds. 11

Verifying the Sensor Clip 3. Verify passed. If successful, the following screen will appear. Press the OK button to return to the Main Menu screen. At this point the verification is complete and no further action is required. 4. Verify failed. If the verification failed, the following screen will appear. Follow these basic steps to address a failed verification of accuracy: 1. Ensure that the sensor clip is properly seated on the verification filter. Refer to page 11 for detailed instructions on how to properly place the sensor clip onto the verification filter. 2. Ensure that the verification filter is clean of any foreign material and that the surface is not scratched or damaged. Refer to page 20 for cleaning instructions. 3. Press the Verify button to repeat the verification of accuracy. If successful, the following screen will appear. Press the OK button to return to the Main Menu screen. At this point the verification is complete and no further action is required. 12

Training Guide Verifying the Sensor Clip 4. If the verification fails again, the following screen will appear. At this point the user may do one of the following: Repeat the verification. Refer to step 12. Verify failed sub-steps 1 through 3 on the previous pages (11-12). Perform a field calibration. Refer to the Field calibration on the sensor clip section below. Change the sensor clip. Refer to Replacing the sensor clip in the User s Guide. Cancel the verification process by pressing the Cancel button. Note: If the operator chooses to cancel a failed verification process, the clip will not be available for patient treatment monitoring. Field Calibration on the Sensor Clip Selecting the Field Calibration button from the Verify failed menu screen allows the user to perform a field calibration on the sensor clip. Note: This option will only be made available if the verification of accuracy fails multiple times. Follow these basic steps to perform a field calibration: 1. Press the Field Calibration button. Once the Field Calibration button is pressed, the following screen will appear. 13

Verifying the Sensor Clip 2. Press the Filter ID button Once the Filter ID button is pressed, the Enter Filter ID screen will appear. 1. Enter the verification filter ID using the onscreen keypad. As characters are entered, they will display in the top window. The filter ID is located in the middle of the verification filter, as shown below: he middle of the verification filter, as sh 2. Once the verification filter ID has been entered, press the Save button. 3. Press the OK button Once the OK button is pressed, a verification of accuracy will be performed as described in the Manually Verify Accuracy on the sensor section. Note: If the verification of accuracy continues to fail, the sensor clip is no longer suitable for clinical use and should be replaced. 14

Training Guide Initiation and Termination of Treatment Review key steps for initiating and terminating treatment on the Crit-Line monitor, being sure to include the following topics: Connecting the Crit-Line Blood Chamber Follow these basic steps to attach the disposable blood chamber to the dialyzer during the extracorporeal bloodline setup before priming the bloodlines. Note: The Crit-Line blood chamber is tinted blue in color and must be used with the Crit-Line monitor. Note: The blood chamber is intended for single-use only. A new sterile blood chamber must be used for each monitoring session. 1. Inspect blood chamber and packaging. Inspect the blood chamber and its sterile package prior to use. Refer to the blood chamber package label to ensure that the blood chamber sterilization has not expired. A Warning: Do not use the blood chamber if its package has been opened or its sterility has otherwise been compromised prior to use. The viewing area of the disposable blood chamber should be kept clean and free of obstruction. 2. Connect blood chamber to dialyzer. Remove the blood chamber from its sterile package and aseptically attach the red connector to the arterial port of the dialyzer. Make sure the connection is tight. 3. Continue setting up the bloodlines. Continue to set up the bloodlines as per the manufacturer s recommendations. Note: When connecting the arterial bloodline to the blood chamber (not the dialyzer), hold the blood chamber securely in one hand and aseptically attach the dialyzer end of the arterial bloodline with the other hand. Be careful that you do not cross-thread the connection. The connection of the blood chamber to the arterial bloodline must not leak. Note: Make sure that no air is in the blood chamber after priming. The accuracy of the hematocrit and oxygen saturation readings may be adversely affected if there is any air present in the blood chamber. 15

Initiation and Termination of Treatment Connecting the Sensor Clip to the Blood Chamber Follow the steps below to attach the sensor clip to the blood chamber before connecting to the patient s vascular access: 1. Pinch open the sensor clip. Hold the sensor clip such that one side is held by the index finger and the other side is held by the thumb. Squeeze the clip to spread the sensor elements apart. 2. Attach sensor clip onto the blood chamber. A Caution: Before attaching the sensor clip, check carefully for leaks at the connections between the blood chamber and the dialyzer, and the blood chamber and the arterial bloodline. Improper attachment of the arterial bloodline to the blood chamber can cause blood or saline to leak onto and into the sensor clip. This can damage the sensor clip. Place the sensor clip over the blood chamber so that the optical sensor covers the lens of the blood chamber. Release the clip to allow the optical sensor to seat on the viewing area of the blood chamber. Make certain that the sensor clip has locked securely into place on the blood chamber by noting the audible and tactile click. Ensure that the sensor clip is perpendicular to the top of the dialyzer and cannot be easily rotated up or down while attached to the blood chamber to ensure its proper placement. Note: Make sure that the sensor clip is properly in place before treatment initiation. If the sensor clip is not properly seated on the Crit-Line blood chamber, the accuracy of the hematocrit and oxygen saturation readings may be adversely affected. 3. Check for proper blood flow before selecting Start Run. When starting the blood pump at the beginning of treatment, visually verify proper blood flow in the extracorporeal circuit, including the blood chamber, before selecting Start Run. 16

Training Guide Initiation and Termination of Treatment Start Run Explain Blood Volume (BV) Alert Level and O 2 Alert Level Function Set initial BV alert level limit BV Alert Level button sets the BV Alert Level. When the current BV% change drops below the set BV Alert Level, the Crit-Line monitor will display the alert message Rel. Blood Volume Low. This message will occur until the user changes the level or sets the BV Alert Level to OFF. To set the BV Alert Level, select the BV Alert Level button and enter the desired value using the arrow (up or down) keys until the desired level is displayed, then press the CONFIRM key. Press CANCEL to return to the original setting. Press the Disable button to set the BV Alert Level to off. The BV Alert Level can be set from -1% to -25%, or 0 for OFF. The default setting is OFF. The BV alert level is drawn as a blue dotted line across the BV graph. In order to set a BV Alert Level, blood must first be sensed. Navigate Screens Setting the Crit-Line Monitor Graph The default Crit-Line monitor graph is the blood volume graph. To change the graph, push the MENU button to enter the Patient Run Option Menu Screen. From this screen, you can choose the BV or Hct graph option by selecting the appropriate button. Reading Graphs on the Crit-Line Monitor Screen The Crit-Line monitor screen can display either blood volume or hematocrit on the upper graph depending on user settings. The default setting is blood volume. On the lower graph, the oxygen saturation graph is displayed. Graphing of the data begins after the user selects Start Run and the sensor clip reads blood sensed and the hematocrit has been stable for sixty seconds. Graphs are displayed for a minimum of four hours (default) and will rescale to accomodate treatments longer than four hours. The graphs are resized larger during the treatment depending on the min/max values and alert levels. Assess Data Points o Hematocrit (Hct) o Blood volume change (%) o Minimum oxygen saturation Adjust BV Alert Level (if necessary) Change Profile Display 17

Initiation and Termination of Treatment Setting an Event Marker Selecting the Marker button displays a menu to insert an event marker on the ΔBV%, Hct and O 2 Sat graphs. 1. Press the Marker button. Once the Marker button is pressed, the event marker selection screen will appear. 2. Select event Marker type. Press the Symptom button to display a yellow diamond t on the graphs. Press the Intervention button to display a black triangle s on the graphs. Press the Cancel button to return without selecting an event marker. Note: To prevent clutter on the graphs, the time between entering a marker must be at least ten minutes apart. If events occur more frequently than ten minutes, the operator must document it manually in the patient treatment record. Note: Adding an event marker encodes the markers in the patient treatment history file. These markers appear on each profile screen in the printed graphs. Note: If the clinical event being marked is a patient symptom, the operator selects the Symptom button. A yellow diamond t on the graphic display indicates an event related to a symptom. Note: If the clinical event being marked is an intervention to prevent a potential symptomatic response from the patient, the operator selects the Intervention button. A black triangle s on the graphic display indicates an event related to an intervention. 3. Confirm selection. Once the marker has been selected, the event marker confirmation screen will appear. 18

Training Guide Initiation and Termination of Treatment Ending a Patient Treatment Monitoring Session 1. Press the End Run button. Once the End Run button is pressed, the End Patient Run option menu will appear. 2. Make selection. Press the Print report button to terminate and print the Crit-Line monitor patient treatment monitoring session. Press the Do not print report button to terminate the Crit-Line monitor patient treatment monitoring session without printing. Press the Cancel button to return to the Crit-Line monitor patient treatment monitoring session. Note: When a Crit-Line monitor patient treatment monitoring session is ended, either by printing or not printing, the system returns to the Patient Run menu. 3. Remove sensor clip from blood chamber. When the treatment is complete, pinch the sensor clip to spread the sensor elements apart and gently remove the sensor clip from the blood chamber. Store the sensor clip by securing it to its verification filter, which is attached to its USB cable. Discard the disposable blood chamber with the rest of the bloodlines following appropriate hazardous waste handling requirements. 19

Initiation and Termination of Treatment Crit-Line Monitor Care Cleaning and Disinfecting the Crit-Line Monitor The Crit-Line monitor is a sensitive electro-optical device. Use care when cleaning the exterior of the Crit-Line monitor, the sensor clip and verification filter so as not to damage them. The exterior of the sensor clip, verification filter, and the Crit-Line monitor should be cleaned after every treatment. These can all be cleaned with dilute bleach solution (1:100) or other suitable hospital disinfectant. Freshly prepared dilute bleach solution (1:100) is currently recommended by the Center for Disease Control as a suitable disinfectant for the hepatitis virus. Because surface contamination is the general mode of transmission for this type of virus, thorough cleaning of the exterior is essential. A Caution: Wipe the Crit-Line monitor and sensor clip with a cloth dampened with the cleaning solution, Do not spray the solution on the Crit-Line monitor or sensor clip. Do not immerse the sensor clip in any type of liquid. If liquids infiltrate the clip, they will damage it. Caution: Do not use abrasive materials or solvents to clean the Crit-Line monitor, sensor clip or verification filter. Doing so may cause damage. Caution: Be careful not to scratch or damage the verification filter. If the verification filter is scratched or damaged, it may cause the sensor clip to fail verification of accuracy. Caution: If the Crit-Line monitor or sensor clip becomes contaminated with blood, it must be thoroughly disinfected before the next treatment. Freshly prepared dilute bleach solution (1:100) or surface disinfectants such as Cavicide or Envirocide are recommended. Sensor Device Disposal If the sensor clip continues to fail verification of accuracy, even after recalibration, it is no longer suitable for clinical use. Disinfect the sensor clip before disposing it in accordance with U.S. federal regulations and appropriate state and local laws. 20

Training Guide Troubleshooting It is important that participants are able to effectively troubleshoot operating alarms as well as treatment results. Review the following resources and steps: Introduce and Explain Common Patient Profiles: BV Profile A BV Profile B BV Profile C Oxygen saturation Points to Consider When Evaluating Patient Profiles: Was the treatment started correctly? Is Hct 30? What was it the last treatment? What is the O 2 saturation? What is the patient s access type? Does the patient need oxygen? Is the BV alert level set? Highlight Common Technical Errors: Did not start properly Setup incorrectly Lab differences between the Crit-Line monitor hematocrit and lab hematocrit Not printing Continue working with alarms and troubleshooting during the hands-on demonstration. 21

Wrapping Up/Hands-on Demonstration Prior to Continuing the Training: Point out the In-Service Training Evaluation, located in the Participant Workbook, and ask participants to complete it at the end of the training. o Completing the evaluation is optional. o Provide the fax number of your manager so that participants can return the evaluation directly (a blank space is provided on the form for the fax number). o If the form is returned to the trainer, review and distribute internally as directed by your manager. If applicable, designate a super user to be the point person for the facility post-training. Conduct the hands-on demonstrations so that each participant has an opportunity to see the Crit-Line monitor in use during a patient treatment. If possible, work with patients who have a more difficult situation to allow for greater opportunities to reinforce intervention learnings. After concluding the hands-on demonstrations, complete the In-Service Training Checklist, sign and return to the facility contact. Conduct Exit Interview with Facility Manager: Determine if additional follow-up and support is needed for the unit; place on the call list as needed. Explain to staff what to expect during follow-up calls and record any additional information. For 24-hour technical and clinical support, facilities may contact 1-800-227-2572. 22

Crit-Line Monitor In-Service Training Sign-in Sheet Training Guide Facility Name: Date: Instructor: Attendees Note: Signatures indicate attendance only, not competence or expertise. 1. Print Name Signature Title 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 23

24

Training Guide Crit-Line Monitor In-Service Training Checklist Facility Name: Date: Address: City: State: Zip: Contact: Phone: Instructor: Title: Training Topics: Topics may be modified to accommodate the specific policies and procedures of the unit being trained. Checks indicate topics reviewed during In-Service Training; no representation is made regarding participant competence or expertise. Crit-Line Monitor Overview Sensor Clip Features Setup and Power on TRAINING TOPICS Ending Treatment Print/Download Results Cleaning Preparation For Treatment Crit-Line Monitor Verification Filter Calibrating the Sensor Clip Verify Accuracy Alarms and Troubleshooting Profiles A, B and C Technical Errors Initiation of Treatment Fix Sensor Clip Attachment Connecting the Sensor Clip to the Crit-Line blood chamber Start Run BV Alert Level Reading Graphs on Crit-Line Monitor Screen Marking an Intervention Instructor s Signature: 25

26

Training Guide Appendix 1. Case Studies (All case studies are for educational purposes only.) 2. Fluid Distribution Model 3. Frequent Asked Questions 27

Case Study: Patient #1 Note: The Crit-Line Monitor Participant Workbook has actual screen shots, patient history and problems. Learning objectives and answers are only in this Guide. Learning Objective: Identify when treatment has been started incorrectly. Patient History: Patient #1 is a 43-year-old male with an AV fistula; he dialyzes M/W/F for three hours and thirty minutes. The patient has gained 2.3 Kg since his last treatment. BP 130/70, pulse 70, respirations 18 and regular. He has no edema noted, lungs clear to auscultation. Renal failure is secondary to application of contrast media. Problem: Treatment was started and the patient quickly dropped into a negative profile. Use the patient history and the Crit-Line monitor data to answer the following questions: 1. Did they initiate the treatment according to operating instructions? No. The blood volume curve immediately went negative. All treatments should start at a blood volume change of 0%. 2. What may have been the cause of the immediate drop in blood volume at the beginning of the treatment? Incorrect setup of the system, for example: saline in the bloodline, air in the blood chamber or perhaps a temporary stoppage of the blood pump. 3. What is the O 2 saturation reading and is the reading reasonable based on the access type? The O 2 Sat reading is 93%, which is a typical value based on the access type of this patient (AV fistula). 4. What is the patient profile at 20 minutes? Profile B. 5. Were BV and O 2 Alert Levels set? If yes, what are these limits? Yes. The BV Limit -15%, O 2 Limit 89%. 6. Based on your assessment, would you recommend any interventions? Yes. If a false start is observed (i.e., the BV% change does not start at 0%) turn the Crit-Line monitor OFF and back ON and start the treatment again. Remember to ensure that all of the saline prime has been pumped out of the extracorporeal tuning prior to starting a patient run. 28

Training Guide Case Study: Patient #2 Learning Objectives: Work with patient in Profile A who has a history of fluctuating post weight. Assess for plasma refill during the last 10 minutes of the treatment Patient History: Patient #2 is a 67-year-old female with R subclavian CVC access used for dialysis while her L AV fistula develops. She dialyzes T/Th/S for three hours and forty-five minutes. She has gained 3.0 Kg since her last treatment, but is only 1.2 Kg above her estimated dry weight. She has been complaining that her weight is always different post treatment depending on her caregiver. Looking back through her treatment records, you notice this is true. Her weight fluctuates by 1.5 Kg. She is an insulin-dependent diabetic patient that has CKD 5 secondary to years of not controlling her diabetes. BP 148/90, pulse 100, respirations 24, mild peripheral edema, assessment shows lobes are clear, bases are full. Problem: Use the patient history and the Crit-Line monitor data to answer the following questions: 1. Was the treatment started correctly? Yes. The BV % change was 0 at the beginning of the treatment. 2. What profile is displayed in the first hour and what profile is displayed between the first and the second hour? Profile A in the first hour, then Profile B in the second hour. 3. What intervention likely occurred with the first intervention marker? Increase in UF Goal to get the Profile A to change to Profile B. 4. What does the second intervention marker indicate? Reduce UF minimum to prevent a steep slope from continuing, or perform a plasma refill check. 5. What does the directional change at the second arrow represent? Plasma refill is present. 6. What is the O 2 saturation reading and is the reading reasonable based on the access type? The O 2 Sat reading is 60%, which is a typical value based on the access type of this patient (CVC). 29

Case Study: Patient #3 Learning Objective: Show a Profile B from the beginning to the end of the treatment; Typical O 2 saturation for access type. Patient History: Patient #3 is an 89-year-old male with a L Internal Jugular (IJ) CVC line. He is scheduled for dialysis M/W/F for three hours. He gains 1.5 Kg between treatments and prides himself in his excellent compliance to all recommendations from his dialysis team. BP 120/80, pulse 68, respiration 20, no peripheral edema, clear lungs and no complaints. Patient history only shows very moderate weight gain between treatments and patient usually is at his dry weight post treatment. Only the fluid gained between treatments has to be removed. Problem: Use the patient history and the Crit-Line monitor data to answer the following questions: 1. Did they initiate treatment according to operating instructions? Yes. 2. Based on your assessment, is this a reasonable profile for this patient? Yes. 3. What is the O 2 saturation reading and is the reading reasonable based on the access type? The O 2 Sat reading is 66%, which is a typical value based on the access type of this patient (CVC) O 2 saturation is appropriate for a central venous catheter. 4. Were BV and O 2 Alert Levels set? If yes, what are these limits? Yes. The BV Limit -15%, O 2 Limit 59%. 30

Training Guide Case Study: Patient #4 Learning Objective: Show patient with Profile C with low O 2 saturation. Participants recognize the opportunity to administer O 2 according a physician s prescription or clinic policies and procedures and decrease UF goal to return patient to Profile B. Patient History: Patient #4 is a 72-year-old male with R IJ CVC access. He dialyzes T/Th/S for three hours. He has an extensive cardiovascular history, including stent placement, previous bypass surgery, and low cardiac output. He is prescribed multiple blood pressure medications, but sometimes forgets to take them at the right time. He arrived for treatment 3.5 Kg over his last post weight and 5.0 Kg away from target weight. BP 90/46, pulse 88 irregular, respirations of 20. His lungs are clear and no edema noted. Problem: Use the patient history and the Crit-Line monitor data to answer the following questions: 1. Did they initiate treatment according to operating instructions? Yes. 2. What profile is being displayed in the first hour of treatment? Profile C. 3. Is the profile in the first hour reasonable for this patient? No, the patient profile was greater than -6.5% per hour. Monitor the patient more closely for potential intradialytic events. 4. What is the O 2 saturation reading and is the reading reasonable based on the access type? The O 2 Sat reading is 59%, which is below the typical value based on the access type of this patient (CVC). 5. In your assessment, do you think the physician needs to consider changes for the next treatment? Yes. Please consult with the physician regarding future treatments in respect to frequency and treatment duration. 6. Was refill present? Yes. 31

Case Study: Patient #5 Learning Objective: Show a patient in Profile A, who has low fluid gain, a lot of residual urine output and does not need additional ultrafiltration. Patient History: Patient #5 is a 54-year-old female with L AV fistula. She dialyzes M/W/F for four hours after she gets off work. She has 0.5Kg weight gain since her last treatment. As you review her chart you note that she rarely gains much weight between treatments. You notice she brought in 2 jugs for her 24-hour urine collection. Her BP is 110/68, pulse 98, and respirations 16, lungs are clear, no edema noted. She is dialyzed at minimum UF. Problem: Use the patient history and the Crit-Line monitor to answer the following questions: 1. What profile does this patient graph exhibit? Profile A. 2. What profile would you expect for this patient given her history and treatment parameters? Profile A seems reasonable for this patient due to a low UF Goal and high urine output. 3. What is the O 2 saturation reading and is the reading within typical range based on the access type? The O 2 Sat reading is 94%, which is a typical value based on the access type of this patient (AV Fistula). 4. Were BV and O 2 Alert Levels set? If yes, what are these limits? Yes. The BV Limit -3%, O 2 Limit 89%. 32

Training Guide Case Study: Patient #6 Learning Objective: Work with situation where BP, Pulse and MAP are elevated, but not enough for alarm; Profile A at treatment start with borderline O 2 saturation. Manage patient weight by increasing UF goal and consider administering oxygen. Convert from Profile A to Profile B and continue to monitor. Patient History: Patient #6 is a 48-year-old female patient that has L AV fistula. She is scheduled for T/Th/S treatment for four hours. She began dialysis nine months ago and continues to use the same dry weight. Her BP is 158/98, pulse 102, respirations 24, peripheral edema noted before and after treatment, lungs are not clear. Due to clinical signs of over hydration, the physician ordered a reduction in dry weight. Problem: Use the patient history and the Crit-Line monitor data to answer the following questions: 1. Was the treatment initiated correctly? Yes. The BV % change started at 0%. 2. Does the profile shown seem reasonable for this patient? Patient initially shows an Profile A which converts into a Profile B after two interventions. These interventions seem reasonable in order to remove the excess fluid. 3. In your assessment, was the O 2 Saturation for this patient adequate throughout the entire treatment? No. The O 2 Sat drops into the 80s on two occasions, which is low for an AVF patient. 4. Did the patient convert to a different profile following the first intervention? No. The patient remained in Profile A. 5. What interventions were possibly made at the first intervention marker? The UF Goal may have been increased and O 2 may have been given. 6. Did the patient convert to a different profile following the second intervention? Yes. The patient converted to Profile B. 7. Was refill observed at the end of the treatment? Yes, but since no marker has been entered, it is hard to tell if a refill check was intended or not. Always make sure to enter an intervention marker when performing a refill check. If patient shows signs of edema despite being at dry weight, consider lowering the dry weight. 33

Fluid Distribution Model Intracellular fluid (without blood cell fluid) Interstitial fluid Blood Circulating BV Peripheral BV Ultrafiltration Dialysate osmolarity Dialysate temperature 34

Training Guide Frequently Asked Questions 1. What are the three main measurements that are measured by the sensor clip? Hematocrit, oxygen saturation and percent change in intravascular blood volume. 2. How does the sensor clip make its measurements? The sensor clip shines a light through the lens of a blood chamber that is placed between the arterial bloodline and the inlet port of the dialyzer. The other end of the sensor clip detects the level of absorption and scattering of the red light as it is transmitted through the patient s blood, which flows through the blood chamber. 3. How does the sensor clip verify that it is measuring accurately? Each sensor clip has its own verification filter that is used to periodically verify its accuracy. This filter is attached to the sensor clip s USB cable. 4. How often should you verify accuracy on the verification filter? When the sensor clip is stored on the verification filter, the Crit-Line monitor automatically verifies the accuracy prior to entering Patient Run Mode. When the sensor clip is not stored on the verification filter, it must be verified once per month. 5. Can the blood chamber be used more than one time? The blood chamber is intended for single-use only. 6. After priming the circuit, what should I look for before connecting the sensor clip to the blood chamber? Make sure that no air is in the blood chamber after priming. Any air present in the blood chamber will cause the hematocrit reading to be inaccurate. 7. What are the default sensor clip graphs displayed on the Crit-Line monitor? The blood volume and oxygen saturation graphs are the default screens displayed. 8. What are the other screens that can be displayed? The blood volume graph can be switched to a hematocrit graph. 9. When the does sensor clip start to take measurements? Graphing of the data begins after the user selects Start Run and the sensor clip reads blood sensed and the hematocrit has been stable for 60 seconds. 10. How are the two types of event markers displayed? The symptom marker is displayed as a yellow diamond. The intervention marker is displayed as a black triangle. 35

FAQs (continued) 11. What is the profile that is displayed? The profile that is displayed is the average percent change in blood volume (ΔBV%) of the previous 15 minutes of data gathered. If the ΔBV% is -3% per hour, the profile will be displayed as Profile A. If the ΔBV% is >-3% per hour and -6.5% per hour, then the profile will be displayed as a Profile B. If the ΔBV% >-6.5% per hour, the profile will be displayed as a Profile C. 12. What is the estimated HB value that is displayed? The hemoglobin value that is displayed is an estimated measurement based on the measured hematocrit. 13. How is percent change in blood volume calculated? The percent change in blood volume is calculated from the following equation: ΔBV% = {(H 2 /H 1 )-1} X 100 H 2 = Initial Hct H 1 = Current Hct 14. What is the default BV Alert Level? The default BV Alert Level is OFF but will be drawn as a blue dotted line across the BV graph once a BV alert value has been entered. 15. What is the default O 2 Sat Level? The O 2 Alert Level default is OFF but can be set from 45 to 95. 16. Can you print out the treatment profiles at the end of a treatment? Yes, treatment profiles can be printed at the end of a treatment. Additional hardware and software are necessary in order to print patient profiles. Technical Support can be reached at 1-800-227-2572. 17. How do you clean the sensor clip? The exterior of the sensor clip and the verification filter should be cleaned after every treatment. These can be cleaned with the standard diluted bleach solution (1:100). Wipe the sensor clip clean with a cloth dampened with a cleaning solution; do not spray the solution directly onto the sensor clip or immerse the sensor clip into any type of liquid. 18. Can the sensor clip still be used if it continues to fail verification? No, if the sensor clip continues to fail verification, it is no longer suitable for clinical use unless it can be re-calibrated (see User s Guide). 19. What do I do if a sensor clip fails to calibrate? The sensor clip must be taken out of service. Contact Technical Support at 1-800-227-2572. 36

Training Guide 37

Fresenius Renal Technologies, a division of Fresenius Medical Care North America 920 Winter Street Waltham, MA 02451 www.fmcna-crit-line.com Customer Service: 800-323-5188 Technical Support: 800-227-2572 2015, Fresenius Medical Care, All Rights Reserved. Fresenius Medical Care, the triangle logo, Fresenius Renal Technologies, Crit-Line and CLiC are trademarks of Fresenius Medical Care Holdings, Inc., and/or its affiliated companies. All other trademarks are the property of their respective owners. P/N 102197-01 Rev A 12/2015 2008T HEMODIALYSIS MACHINE WITH sensor DEVICE TRAINING GUIDE