ANALYSIS OF GASES PRODUCED BY THREE UNDERWATER CUTTING DEVICES

Similar documents
Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

EVALUATION OF THE KMS 48 FULL FACE MASK WITH THE VIPER VERY SHALLOW WATER UNDERWATER BREATHING APPARATUS

NN- NAVY EXPERIMENTAL DIVING UNIT SECNIALRPOR NO. 6-9 NAV EPEIMETAL DI VING UIT~ TIC-99 DTIC QUAJLIXDISPECTED X

EVALUATION OF INTRAVENOUS THERAPY DEVICES IN THE HYPERBARIC CHAMBER

200602q PULMONARY FUNCTION AFTER OXYGEN-ACCELERATED DECOMPRESSIONS FROM REPETITIVE SUB-SATURATION AIR DIVES

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES

POTENTIAL BENEFITS OF NAVY DIVE COMPUTER USE IN SHIPS HUSBANDRY DIVING: ANALYSIS OF DIVES CONDUCTED ON THE USS RONALD REAGAN (CVN-76)

CHAPTER 16 %UHDWKLQJ*DV0L[LQJ3URFHGXUHV

APPLICATION NOTE. Fast Analysis of Coal Mine Gas Using the INFICON 3000 Micro GC ABSTRACT

D TIC 0 F U AD-A IllllllIII ELECTE f1 JUN2 71M4 DEPARTMENT OF THE NAVY

Multiple Gas#5 GC configuration Jan 2016

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

UNMANNED TEST AND EVALUATION OF THE TELEDYNE ANALYTICAL INSTRUMENTS R-10DN OXYGEN SENSOR FOR USE IN THE MK 16 MOD 1 UNDERWATER BREATHING APPARATUS

HARDWARE AND PROCEDURES FOR USING THE DIVEAIR2 MONITOR TO TEST DIVING AIR QUALITY IN THE FIELD

PRECISION GAS MIXTURES

PERFORMANCE SPECIFICATION PROPELLANT, HYDROGEN

AD-A Ott, pp, ELECTE NAVY EXPERIMENTAL DIVING UNIT

Demystifying the Process of Calibrating your Thermal Desorption Gas Chromatography System using Compressed Gas Standards.

AD-A DIVING UNIT NAVY EXPERI:MENTAL ...DTIC ILKICT[ 000 CTL14 Ift,

DEVELOPMENT AND EVALUATION OF AN ONLINE AIR QUALITY MONITOR (DIVEAIR2) FOR DIVING COMPRESSORS

Optimizing Gas Supply for Industrial Lasers

Gases and welding distributors continue

PERFORMANCE SPECIFICATION PROPELLANT PRESSURIZING AGENT, ARGON

Gas Mixture Two Components. Gas Mixtures Two Components

Experiment GC : Analysis of BTEX by GC-FID

DETERMINATION OF TETRAHYDROTHIOPHENE IN AMBIENT AIR BY GAS CHROMATOGRAPHY WITH A PFPD DETECTOR COUPLED TO A PRECONCENTRATION TECHNOLOGY

LINEAR TRANSFORMATION APPLIED TO THE CALIBRATION OF ANALYTES IN VARIOUS MATRICES USING A TOTAL HYDROCARBON (THC) ANALYZER

VIC offers a variety of Calibrated Gas Leaks

HiQ laboratory gas generators.

GAS DETECTION: CALIBRATION GAS

Technical Operating Instructions for Magnum Cutting Systems. for online instructions

STANDARD OPERATING PROCEDURES

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Nonrefillable Cylinders

Supporting Information for Micro-Collection of. Gases in a Capillary Tube: Preservation of Spatial

:Q WfiEi~RW DIVING UNIT~

Flare Gas Composition Analysis and QA/QC Lessons Learned and Lessons Lost SPECTRUM ENVIRONMENTAL SOLUTIONS, LLC 1

Underwater Welding & Cutting

SUBMARINE BASE, GROTON, CONN. REPORT NUMBER 855

Super-Clean Gas Filters from Restek

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

Description Advanced Features Typical Applications

Specialty Gases & Equipment ISO 9001: 2008 CERTIFIED. A Division of Norco, Inc.

General Specifications: Forensic. Petrochemical Environmental. Lab Quality Analyses in the Field, It Goes with you Anywhere!

A New GC/MS System Designed for Helium Carrier Gas Conservation

The Role of Gas Monitoring in the Prevention and Treatment of Mine Fires

AVExPERIMENTAL DVING UNIT

Svensk läkemedelsstandard

Gas Chromatography. MS Vent Enhancement to the PreVent System to Optimize Operation with the TurboMass, TurboMass Gold, and Clarus 500 GC/MS Systems

Model Description

Gas Measurement Fundamentals Certification. Curriculum

XVAL-HE-4B: A MAXIMUM PERMISSIBLE TISSUE TENSION TABLE FOR REAL-TIME THALMANN ALGORITHM SUPPORT OF CONSTANT 1.3 ATM PO 2 -IN-HELIUM DIVING TO 200 FSW

Background Statement for SEMI Draft document 4657B NEW STANDARD: SPECIFICATIONS FOR TUNGSTEN HEXAFLUORIDE (WF 6 )

NITROGEN GENERATION FOR INDUSTRIAL APPLICATIONS

ISO INTERNATIONAL STANDARD

Introduction. U.S. Navy Diving Manual (Mar-1970)

The Helium Leak Detector

Gas-Detection Instruments

Date of Shipment: Xxxxx 00, 20xx 3402c National Institute of Advanced Industrial Science and Technology National Metrology Institute of

STANDARD OPERATING PROCEDURES

Retention Time Locking: Concepts and Applications. Application

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

Your local gas generation partner. Precision series Modular gas generation solution for GC.

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

Commercial Practice Test Method Internal Vapor Analysis of Hermetic Devices

High Automation of Thermo Scientific FlashSmart CHNS/O Analyzer using the MultiValve Control (MVC) Module

ELEDT S APR24 19 DECOMPRESSION SICKNESS AFFECTING THE TEMPOROMANDIBULAR JOINT. Author:

Svensk läkemedelsstandard

This standard is due for Five Year Review. This process is required by the SEMI Regulations to ensure that the standard is still valid.

Your local gas generation partner. Precision series Modular gas generation solution for GC.

DEVICES FOR FIELD DETERMINATION OF WATER VAPOR IN NATURAL GAS Betsy Murphy MNM Enterprises 801 N. Riverside Drive Fort Worth, Texas 76111

Gas Leak Measurement of TRT Barrel Module

REFINERY GAS ANALYSIS BY GAS CHROMATOGRAPHY

APPLICATION NOTE. GC Integrated Permeation Device

8.1 Calibration of gas sensors

Zebron Gas Management

28 Site Preparation. Supplying valve actuator air

Safety Tips from the WorkSafe People. Building a Safety Program for Your Organization

Cal/OSHA T8 CCR 1536 Cal/OSHA T8 CCR 4799 Cal/OSHA T8 CCR 4845 Cal/OSHA T8 CCR 4848

Describe Flammable Gas Measurement

Generating Calibration Gas Standards

Discovery HP-TGA 75/750. Site Preparation Guide

Space product assurance

Review of the Hall B Gas System Hardware. George Jacobs

800.Keen.Gas

DTIC 1111II IGI~ ~I HI II17 04 AD-A NAVY EXPERIMENTAL DIVING UNIT REPORT NO OMMERCIALLY AVAILABLE IDI SCUBA REGULATORE

System Overview. TCD Detector temperature setpoint Regulator

ISO INTERNATIONAL STANDARD. Welding consumables Gases and gas mixtures for fusion welding and allied processes

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

Three Columns Gas Chromatograph Analysis Using Correlation between Component's Molecular Weight and Its Response Factor

HYDROGEN - METHANE MIXTURES : DISPERSION AND STRATIFICATION STUDIES

METHOD 21 - DETERMINATION OF VOLATILE ORGANIC COMPOUND LEAKS. 1.2 Scope. This method is applicable for the

MATHESON s LaserPro Gases and Gas Delivery Equipment

PERFORMANCE SPECIFICATION PROPELLANT PRESSURIZING AGENT, NITROGEN

Environmental Petrochemical, Pharmaceutical, Foods & Flavors, Chemicals, Personal Care, Forensics,...and more!

Welding, Cutting, and Brazing

Transcription:

Navy Experimental Diving Unit (NEDU) TA 03-01 321 Bullfinch Rd. NEDU TR 03-13 Panama City, FL 32407-7015 July 03 ANALYSIS OF GASES PRODUCED BY THREE UNDERWATER CUTTING DEVICES Navy Experimental Diving Unit ~~~ "3 95 Authors: R.S. Lillo, Ph.D. Distribution Statement A: J.M. Caldwell, B.S. Approved for public release; distribution is unlimited.

SECURITY CLASSIFICATION OF THIS PAGE REPORT DOCUMENTATION PAGE la. REPORT SECURITY CLASSIFICATION lb. RESTRICTIVE MARKINGS Unclassified 2a. SECURITY CLASSIFICATION AUTHORITY 3. DISTRIBUTION/AVAILABILITY OF REPORT DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited. 2b. DECLASSIFICATION/DOWNGRADING AUTHORITY 4. PERFORMING ORGANIZATION REPORT NUMBER(S) 5. MONITORING ORGANIZATION REPORT NUMBER(S) NEDU Technical Report No. 03-13 6a. NAME OF PERFORMING 6b. OFFICE SYMBOL 7a. NAME OF MONITORING ORGANIZATION ORGANIZATION (If Applicable) Navy Experimental Diving Unit None 6c. ADDRESS (City, State, and ZIP Code) 7b. ADDRESS (City, State, and Zip Code) 321 Bullfinch Road, Panama City, FL 32407-7015 8a. NAME OF FUNDING SPONSORING 8b. OFFICE SYMBOL 9. PROCUREMENT INSTRUMENT IDENTIFICATION NUMBER ORGANIZATION (If Applicable) NAVSEA (0OCS) 8c. ADDRESS (City, State, and ZIP Code) 10. SOURCE OF FUNDING NUMBERS 1333 Isaac Hull Ave SE PROGRAM ELEMENT NO. PROJECT TASK NO. WORK UNIT Washington Navy Yard DC 20376-0001 NO. ACCESSION NO. 03-01 11. TITLE (Include Security Classification) (U) ANALYSIS OF GASES PRODUCED BY THREE UNDERWATER CUTTING DEVICES 12. PERSONAL AUTHOR(S) R.S. Lillo, Ph.D. J.M. Caldwell, B.S. 13a. TYPE OF REPORT 13b. TIME COVERED 14. DATE OF REPORT (Year, Month, Day) 15. PAGE COUNT Technical Report Jan - June 2003 July 2003 9 16. SUPPLEMENTARY NOTATION 18. SUBJECT TERMS (Continue on reverse if necessary 17. COSATI CODES and identify by block number) FIELD GROUP SUB-GROUP diving, salvage, underwater burning 19. ABSTRACT (Continue on reverse if necessary and identify by block number). Please see page ii. 20. DISTRIBUTION/AVAILABILITY OF ABSTRACT 21. ABSTRACT SECURITY CLASSIFICATION D UNCLASSIFIED/UNLIMITED E SAME AS RPT. n DTIC USERS Unclassified 22a. NAME OF RESPONSIBLE INDIVIDUAL 22b. TELEPHONE (Include Area Code) 22c. OFFICE SYMBOL NEDU Librarian 850-230-3100 03 DD Form 1473 UNCLASSIFIED SECURITY CLASSIFICATION OF THIS PAGE

UNCLASSIFIED SECURITY CLASSIFICATION OF THIS PAGE ABSTRACT The gas produced during underwater testing of 3 cutting systems was collected and analyzed to assess the explosion hazard related to the 3 processes. The underwater plasma cutting system produced up to 6% H 2, while the UK cutting rod produced up to 95% H 2. As the lower flammable/explosive limits of H 2 in air are 4%, H 2 safety issues are potentially related to using both these cutting processes. However, the explosive risk associated with the plasma cutting system appears much lower than that with the UK cutting rod, due to the substantially lower concentration of H 2 generated. The Broco cutting rod produced more than 90% 02, an amount of 02 associated with this cutting process that has long been recognized as a high risk factor. Unfortunately, the detection of up to 3.6% H 2 in the system check casts some concern on the reliability of the samples drawn during the actual cutting tests.

CONTENTS DD Form 1473... i A b stra ct... ii Contents... iii Intro d u ctio n... 1 M e th o d s... 1 Cutting Testing... 1 Gas Analysis... 3 Results and Discussion... 3 Reference... 5 iii

INTRODUCTION Underwater cutting has long been recognized as a hazardous task that has injured or killed divers. The current cutting method commonly used by the U.S. Navy uses a Broco cutting electrode with an oxygen (02) source for ignition and cutting, a device that produces large volumes of explosive gas. For these reasons, Naval Sea Systems Command (NAVSEA 00C5) is interested in identifying alternative, safer methods for underwater cutting. In January 2003, NAVSEA 00C5 tasked the Navy Experimental Diving Unit (NEDU) to examine the gas composition produced by various types of underwater cutting equipment and assess the explosion hazards related to the evolved gas. Along with this task, we provided technical direction as well as gas sampling cylinders for collecting the gas during the cutting tests. CUTTING TESTING METHODS NAVSEA 0005 contracted Phoenix International (Morgan City, LA) to evaluate the performance of the following 3 underwater cutting processes (ensuing information is from Phoenix International) in its underwater test tank: 1. Plasma Cutting System manufactured by Thermal Dynamics Corp. (West Lebanon, NH). Model: Pak 44 Plasma Cutting System. This system creates a plasma gas by combining an electrical current with an inert gas (N 2 ); a secondary gas (CO 2 ) is used to flush the molten metal away from the cutting path. 2. Broco Underwater Ultrathermic Cutting System (commonly referred to as Broco cutting rod) manufactured by Aqua Air Industries, Inc. (Harvey, LA). Model: BR- 22 Torch, HVR-4400 Regulator. This system delivers 02, ignited by an electrical current, through the core of a rod. 3. UK Underwater Cutting System (new), developed by Jones Marine (London, UK). Model: Portland Technologies e-rod cutting electrodes. This system generates an electrical arc through a standard welding torch. Before collecting and testing any gas, we discussed the experimental approach with personnel at Phoenix International and offered suggestions to ensure reliable sampling. These suggestions included: 1. using clean hardware, preferably of metal, and avoiding soft material (e.g., plastic tubing) in constructing the gas sampling setup;

2. purging the system adequately during each test before conducting actual sampling; 3. taking triplicate samples during each test to allow repeated analysis, in accordance with good analytical practices, to confirm sampling reliability (Multiple samples would also provide extra gas for analysis, as pressure during cutting tests was expected to be -1 atmospheres absolute [ATA] at the point of sample collection.); and 4. conducting system checks by flushing the system with clean gas and taking gas samples from the test setup when no cutting device was being used. Phoenix International then wrote a final test plan, and we sent 12 evacuated, high-purity gas sampling cylinders to the company before testing started. Phoenix International personnel conducted all test procedures, including collection of gas samples. To evaluate the performance of the 3 cutting systems, the testing measured variables such as cutting times, cutting lengths, and amounts of rod used and gas produced. Performance results will be reported separately by Phoenix International. During the actual test, a diver working -5 feet beneath the surface of the underwater test tank used one of the 3 cutting methods to cut a 5/8-inch steel plate. The gas produced during each cutting process was collected in a hood (< 0.5 ft 3 gas-collection volume) made of Lexan and mounted in the test tank over the cutting area, and was routed to the surface through metal tubing and collected in the sample cylinders. Each test was begun with the hood completely filled with water. The cutting was then started, and the gas that was produced was allowed to completely displace the water and purge the sampling tubing through the sampling valve on the surface. This purging was then repeated by refilling the hood with water and allowing gas to flow through the collection tubing a second time. This purging was repeated a third time, at which time the cylinders were individually attached to the sampling valve on the surface to take triplicate samples. After the 3 cutting procedures had been tested, the hood was placed in a water barrel at the surface and filled with commercial grade N 2 to allow a system check to be made. A -20-foot high-pressure hose was used to deliver the N 2 to the water barrel setup. Purging and sampling procedures were similar to those used for the cutting tests. The test schedule was as given: 27 Jan 2003 1500 - UK cutting system 29 Jan 2003 1000 - Plasma cutting system 1500 - Broco cutting system 1530 - System check 2

GAS ANALYSIS Before analysis began, the sample cylinders were vented to the atmosphere and then backfilled to 30 psig with zero grade N 2 to produce sufficient amounts of gas under pressure to facilitate loading the gas chromatographs. Other sample cylinders that had been filled with calibration gas standards were backfilled in identical fashion to confirm the dilutional ratio. All gas concentrations reported in the table (see RESULTS AND DISCUSSION) were corrected for this dilutional procedure. Two different gas chromatography (GC) systems with molecular sieve columns and thermal conductivity detectors - one system using helium as the GC carrier gas and the other using argon - measured 02, hydrogen (H 2 ), and N 2 levels. Gas chromatography coupled to a methanizer was used to measure C02 and carbon monoxide (CO). Volatile organic compounds (VOCs) were analyzed by GC configured with flame ionization detectors with 2 different columns supplied by Supelco (Bellefonte, PA): 1) a 10-ft long, 1/8-inch stainless steel packed column, 3% SP-1 500 on 80/120 Carbopack B, and 2) a 60-m long, 0.53-mm id, wide bore glass capillary column, Supelcowax 10, 1.0 micron film. These columns allowed detection of a wide range of VOCs below the 0.1 ppm level. We did not perform detailed characterizations of the VOCs with our GC/mass spectrometer: this work focused on explosive risk, and the observed VOC levels were considered well below those meriting concern. Primary gravimetric standards were used to quantify results, although the high levels of some components in some of the samples were well above the levels in our standards. This difference between sample and calibration concentrations was unavoidable, as the selection of gas standards before analysis was partly based on a guess about the expected sample composition. Consequently, extrapolation was necessary for some of the quantitation; this extrapolation affected the level of uncertainty associated with our reported values, as indicated in RESULTS AND DISCUSSION. RESULTS AND DISCUSSION Gas analysis results are given in the table below. The range in concentrations represents differences among the triplicate cylinders. All cylinders were not analyzed for all components, however, partly because adequate gas was unavailable. For these reasons, when the percentages are added together (e.g., for the UK cutting rod), they may exceed 100%. 3

GAS ANALYSIS RESULTS Plasma Broco UK Cutting System Cutting Cutting Rod Check System Rod 02 0.1% 88-93% 0.5% 0.2% C02 1.5% 1.2% 2.8% 445 ppm CO 3.9% 0.2% 5.1% 6 ppm H2 5-6% 0.5% 75-95% 0-3.6% Methane 3 ppm 15 ppm 0.1% 1.7 ppm VOCs -25 ppm -30 ppm -0.2% -10 ppm Balance N2 - N 2 N2 N2 Accuracy for analysis of 02, C02, and H 2 is estimated at ±2% relative, but greater uncertainty should be expected for H 2 > 10%. Accuracy for CO is estimated at ±2 ppm, except for CO > 100 ppm. Accuracy for methane and VOCs is ±20% relative, except for levels > 100 ppm. VOCs exclude methane. The detection of up to 3.6% H 2 in the system check suggests that some sample gas carried over from previous testing, although the Broco test immediately preceding the system check did not produce substantial H 2. This result from the system check was discussed in detail with Phoenix International, and no reason for the anomaly could be determined. Unfortunately, the presence of H 2 in the system check raises some concern about the reliability of the samples drawn during the actual cutting tests. The underwater plasma cutting system produced up to 6% H 2 along with 2% CO 2 and 4% CO. The UK cutting rod produced up to 95% H 2 as well as 3% CO2, 5% CO, 0.1% methane, and 0.2% VOCs. For comparison, the Institute of Naval Medicine has recently reported that up to 8% of the lower explosive limit (LEL) of H 2 (or -0.3% H 2 ) was detected with multigas monitors during underwater cutting with a Goodwin Air Plasma arc cutter. 1 As the lower flammable/explosive limits of H 2 (in air) are 4% and those of methane (in air) are 5%, potential H 2 safety issues appear to be related to using the underwater plasma cutting system and the UK cutting rod if the gas that is produced collects in pockets and an 02 source such as air is present. However, the explosive risk associated with the plasma cutting system appears much lower than that with the UK cutting rod because of the plasma cutting's lower concentration of H 2. The Broco cutting rod produced more than 90% 02, along with 1% C02. That large amount of 02 associated with the Broco cutting rod has long been recognized as a high risk. 4

REFERENCE 1. P.J.T. Nicolson, S. Moore, J. Holmes, and R. Shayer. Exposure to hazardous substances and noise during surface and submerged air plasma arc cutting trials at Horsea Island. Institute of Naval Medicine Report No. 2001.016, 2001. 5