QED-100 Clinical Brief

Similar documents
VIMA. (Volatile Induction and Maintenance Anesthesia) How and Why. James H. Philip M.E.(E), M.D.

Capnography in the Veterinary Technician Toolbox. Katie Pinner BS, LVT Bush Advanced Veterinary Imaging Richmond, VA

Mechanical Ventilation

CARBON DIOXIDE ELIMINATION FROM SEMICLOSED SYSTEMS

Disclosures. The Pediatric Challenge. Topics for Discussion. Traditional Anesthesia Machine. Tidal Volume = mls/kg 2/13/14

ROUTINE PREOXYGENATION

Chapter 4: Ventilation Test Bank MULTIPLE CHOICE

Selecting the Ventilator and the Mode. Chapter 6

VENTILATORS PURPOSE OBJECTIVES

Chapter 9 Airway Respirations Metabolism Oxygen Requirements Respiratory Anatomy Respiratory Anatomy Respiratory Anatomy Diaphragm

Guidelines on Monitoring in Anaesthesia

ONLINE DATA SUPPLEMENT. First 24 hours: All patients with ARDS criteria were ventilated during 24 hours with low V T (6-8 ml/kg

Historically, rebreathing anesthesia systems

6 th Accredited Advanced Mechanical Ventilation Course for Anesthesiologists. Course Test Results for the accreditation of the acquired knowledge

Selecting and Connecting Breathing Systems

Anesthesia Machines. Inhaled Anesthetic Agents

Fiberoptic Intubation Made Easi(er) Know Your Scope. Indications. Christine Whitten MD Department of Anesthesia Kaiser Permanente San Diego

Breathing Circuits. Product training

ACUC ۰ ROUTINE PROCEDURE

Collin County Community College. Lung Physiology

Mechanical Ventilation. Mechanical Ventilation is a Drug!!! is a drug. MV: Indications for use. MV as a Drug: Outline. MV: Indications for use

Airway Control and Ventilation... 1 Adult... 1 Pediatric... 1 Neonate... 2 Jones & Bartlett Learning, LLC NOT FOR SALE OR DISTRIBUTION

Update on Thoracic Anesthesia: Perioperative Lung Protective Strategies in One- and Two-Lung Ventilation

Lung Volumes and Capacities

APNOEA AND PRE-OXYGENATION

J.A. BAIN AND W.E. SPOEREL~

Monitoring, Ventilation & Capnography

Proceedings of the World Small Animal Veterinary Association Sydney, Australia 2007

Day-to-day management of Tracheostomies & Laryngectomies

Errors in Monitoring. BWH Clinical Conference 10/06/04. Copyright 2004, James H Philip, all rights reserved.

Presentation Overview. Monitoring Strategies for the Mechanically Ventilated Patient. Early Monitoring Strategies. Early Attempts To Monitor WOB

Standard Operating Procedure

CARBON DIOXIDE METABOLISM AND CAPNOGRAPHY

Comparison Of The Efficacy Of Two Low Fresh Gas Flow Techniques In Low Flow Anaesthesia

Lab 3. The Respiratory System (designed by Heather E. M. Liwanag with T.M. Williams)

27/10/58. Background and Rationale. Background and Rationale. Background and Rationale. Objective. Background and Rationale

The physiological functions of respiration and circulation. Mechanics. exercise 7. Respiratory Volumes. Objectives

PICU Resident Self-Study Tutorial The Basic Physics of Oxygen Transport. I was told that there would be no math!

Respiratory Physiology Gaseous Exchange

Recommendations on Checking Anaesthesia Delivery Systems

Let s talk about Capnography

NOTE: If not used, provider must document reason(s) for deferring mechanical ventilation in a patient with an advanced airway

Mechanical Ventilation. Which of the following is true regarding ventilation? Basics of Ventilation

INTRODUCTION TO BI-VENT (APRV) INTRODUCTION TO BI-VENT (APRV) PROGRAM OBJECTIVES

New Frontiers in Anesthesia Ventilation. Brent Dunworth, MSN, CRNA. Anesthesia Ventilation. New Frontiers in. The amount of gas delivered can be


II. Set up the monitor

Initiation and Management of Airway Pressure Release Ventilation (APRV)

Name: Oasis: Questions EPCP. Professional Development: ETCO2 Monitoring

Notes on BIPAP/CPAP. M.Berry Emergency physician St Vincent s Hospital, Sydney

HONG KONG COLLEGE OF ANAESTHESIOLOGISTS TECHNICAL GUIDINES RECOMMENDATIONS ON CHECKING ANAESTHESIA DELIVERY SYSTEMS

PARTS AND STRUCTURE OF THE RESPIRATORY SYSTEM

Working version subject to Departmental approval. Drafted by Dr. Olympio and reviewed by clinical members of The Capital Equipment Committee

VENTILATION AND PERFUSION IN HEALTH AND DISEASE. Dr.HARIPRASAD VS

Automatic Transport Ventilator

EMS INTER-FACILITY TRANSPORT WITH MECHANICAL VENTILATOR COURSE OBJECTIVES

Medical Ventilators. Presented by: Edwin Lim

Hallowell EMC 2000 and 2002 Veterinary Ventilator Set-up, Use, and Troubleshooting

Activity 2: Examining the Effect of Changing Airway Resistance on Respiratory Volumes

APRV: Moving beyond ARDSnet

Practical considerations in anaesthetising exotic species. By Keith Simpson BVSc MRCVS AMIIE(Electronics).

Physiology Unit 4 RESPIRATORY PHYSIOLOGY

Health Professional Info

Respiratory Response to Physiologic Challenges. Evaluation copy

Test Bank for Pilbeams Mechanical Ventilation Physiological and Clinical Applications 6th Edition by Cairo

Respiratory Physiology 2

MEDICAL EQUIPMENT IV MECHANICAL VENTILATORS. Prof. Yasser Mostafa Kadah

o An experienced and trained assistant is available to help you with induction.

Page: 1 of 6 Responsible faculty: (Signature/Date)

Homecare Pneumology NEONATOLOGY ANAESTHESIA INTENSIVE CARE VENTILATION Step beyond the future

RESPIRATORY REGULATION DURING EXERCISE

We Warm Animals. User Manual For. Darvall Heated Smooth-Wall Circuits. Darvall Heated ZDS Qubes

Corporate Overview and Product Summary

Capnography. The Other Vital Sign. 3 rd Edition J. D Urbano, RCP, CRT Capnography The Other Vital Sign 3 rd Edition

Using Common Ventilator Graphics to Provide Optimal Ventilation

Anesthesia. Midmark Animal Health Products

Anesthesia Machine Intro

Breathing Process: Inhalation

GE Healthcare. Avance Carestation. Upgrade promotions guide

ALVEOLAR - BLOOD GAS EXCHANGE 1

V8600 Ventilator. Integrated Invasive & Noninvasive Ventilation

LAB 7 HUMAN RESPIRATORY LAB. Complete the charts on pgs. 67 and 68 and read directions for using BIOPAC

Definition An uninterrupted path between the atmosphere and the alveoli

Effect of Fresh Gas Flow on Isoflurane Concentrations during Low-flow Anaesthesia

Sign up to receive ATOTW weekly -

PROBLEM SET 9. SOLUTIONS April 23, 2004

Using the laryngeal mask airway to manage the difficult airway

Pressure Controlled Modes of Mechanical Ventilation

Airways and Resuscitators. CRC 330 Cardiorespiratory Care University of South Alabama

Organis TestChest. Flight Simulator for Intensive Care Clinicians

Laryngeal Mask Airway (LMA) Indications and Use for the NH EMT-Intermediate and Paramedic

PRODUCT CATALOG. Every Breath Matters. ARC Medical, Inc. circuitguard ThermoFlo PneumoniaCheck Cowan Road Tucker, GA 30084

Emergency Medical Technician 60 Questions

Department of Biology Work Sheet Respiratory system,9 class

Performance Redefined. Automatic Gas Control (AGC) FLOW-i Anesthesia Delivery System

New A7 Anesthesia Workstation

Isoflurane: Safe Use Guidelines. (2-chloro-2-(difluoromethoxy)-1,1,1- trifluoro-ethane) is a halogenated ether used for inhalational anesthesia.

Unit 15 Manual Resuscitators

Advanced Ventilator Modes. Shekhar T. Venkataraman M.D. Professor Critical Care Medicine and Pediatrics University of Pittsburgh School of Medicine

Mechanical Ventilation

Transcription:

QED-100 Clinical Brief THE QED-100 WITH SPONTANEOUSLY BREATHING PATIENTS Author: Derek Sakata, MD Assistant Professor of Anesthesiology University of Utah Department of Anesthesiology QED-100 offers clinical value with spontaneously breathing patients. Cerebral blood flow increases with increased PaCO 2 SUMMARY The QED-100 provides a safer and faster emergence from inhaled anesthetics in spontaneously breathing patients. It can be used during emergence when the patient is breathing through a Laryngeal Mask Airway (LMA), or a face mask. In spontaneously breathing patients, an activated QED-100 uses rebreathing of CO 2 to raise the patient's PaCO 2. This respiratory stimulant increases the patient's spontaneous tidal volume and respiratory rate, which speeds the rate of removal of the inhaled anesthetic from the lungs. The respiratory stimulant also helps the patient breathe through the laryngeal mask or face mask, the airway filter, the QED- 100 and the anesthesia circuit, overcoming their combined resistance. When the QED-100 is used in spontaneously breathing patients, respiratory monitoring is needed to insure that the patient breathes with a tidal volume of at least 500 ml. This provides adequate oxygenation during rebreathing. If the fraction of inspired oxygen drops below 35% or the oxygen saturation drops below 90%, the QED-100 should be deactivated. INTRODUCTION The QED-100 was formally tested for emergence from inhaled anesthetics under controlled ventilation. The use of the QED-100 to enhance emergence from inhaled anesthetics during spontaneous ventilation is a topic which is being addressed subsequent to questions arising from new users of the QED-100. Although use of the QED-100 with spontaneous ventilation has been accomplished with a limited number of cases. The QED-100s expected performance characteristics will be detailed in this brief. PHYSIOLOGY Of course, oxygenation of the patient is paramount! Oxygenation requires adequate ventilation with an adequate amount of oxygen. Given that, it is important to realize that the QED-100 imparts partial re-breathing of the patient s previous breath to achieve emergence from inhaled anesthesia. Since the previous breath is lacking a certain percentage of oxygen and has an increased percentage of CO 2, a mixing of new gas is required to maintain an adequate percentage of oxygen within the QED-100 device. The volume of dead space in use during full expansion of the QED-100 s rebreathing loop is ~750 ml. As such, it is imperative that the user understand that a certain patient tidal volume (500 ml) is advocated in order to maintain adequate mixing of exhaled (used) gas and new gas. However, it should also be noted that there are instances of tidal volumes less than 500 ml that have been reported without oxygen desaturation occurring. With partial rebreathing the end tidal carbon dioxide level will become inspired carbon dioxide and thereby increase the fraction of inspired CO 2 (FiCO 2 ) and thus PaCO 2. The effect of increasing PaCO 2 not only increases cerebral blood flow velocity (Figure 1), but also increases the drive to breathe (Figure 2). This is especially important during spontaneous ventilation while under the influence of inhaled anesthetics and opioids due to their respiratory depressing effects. Figure 1. Cerebral Blood Flow Velocity vs. EtCO 2 1

QED-100 Clinical Brief Page 2 have patients breathing spontaneously during their use. If, however, a patient is intubated, the use of muscle relaxants for the intubation process and possibly throughout the case may be a more common practice. If that is the case, a patient may start to show signs of spontaneous respiration if the paralytics are given time to wear-off. The anesthetist may attempt to allow the patient to breathe on his or her own by turning off the ventilator. It is entirely possible that the patient may breathe spontaneously but with minimal tidal volumes due to residual muscle paralytics augmented by the volatile anesthetic. Respiratory Depressants: Opioids Paralytics Respiratory Physics Figure 2. PaCO 2 and Drive to Breathe 2 Curve A: Normal, no anesthetic drug effect. Curve B: Light anesthetic effect Curve C: Deeper anesthesia RESPIRATORY DEPRESSANTS In addition to maintaining oxygenation, the purpose of ventilation is to clear the body of waste products such as CO 2. As stated in the previous paragraph it is known that CO 2 stimulates respiration thereby preventing its build-up. This primarily occurs due to a decrease in respiratory tidal volume. Opioids Opioids such as the fentanyl family, morphine, hydromorphone or meperidine are usually therapeutically necessary during any procedure in which a general anesthetic is required. The benefits of adding opioids to an anesthetic are to help with discomfort after surgery (analgesic effect) but, also to help the anesthetist use less inhaled anesthetics during the surgical case. In addition to its analgesic effect, opioids also have a respiratory depressive effect. This respiratory depressive effect is more profound than that seen with the volatile anesthetics and synergistically adds to the respiratory depression caused by the volatile anesthetics. In addition, its respiratory depressive effect is seen primarily with regard to depression of respiratory rate. Paralytics Another spontaneous respiratory deterrent is the use of paralytics. Paralytics are not typically used with LMAs since it is common practice to Respiratory Physics A primarily physical reason a patient may not be able to generate a large tidal volume may be due to their inability to overcome breathing resistance. This resistance occurs due to circuit restrictions from the endotracheal tube or the LMA, the humidivac filter, the QED-100 and the anesthesia circuit itself. It must be remembered that with fluid (gas or liquid) flow, resistance is directly proportional to tube length. So, the longer the breathing circuit that is hooked up to the patient, the more resistance they have to breathe through. Decreasing the cross sectional area or radius of the tube can also drastically increase the resistance while breathing. RESPIRATORY STIMULANTS Carbon Dioxide Although it will take more CO 2 in their system in order to stimulate spontaneous breathing, carbon dioxide still works as a stimulant to help patients increase their minute ventilation under anesthesia with volatile anesthetics. The amount of CO 2 needed to achieve increased tidal volumes will depend on how much respiratory depressant such as opioids, volatile anesthetic and/or muscle relaxant are on board. This, of course, will be balanced against the respiratory stimulants such as surgical or pain stimulation, airway stimulation, decreasing amounts of volatile agent and/or opioids. Discomfort and Pain It is important to realize that any sort of irritant such as surgical discomfort or airway stimulation can stimulate spontaneous breathing. Conversely, inadequate management of the painful

QED-100 Clinical Brief Page 3 Respiratory Stimulants: Carbon Dioxide Discomfort and Pain Combination Effects Coughing on the endotracheal tube: Tidal volume may suffer O 2 use increases CO 2 production increases stimulus whether due to insufficient doses of opioids or anesthetics can also lead to stimulation of spontaneous breathing. One should also be aware of the irritating impact of an endotracheal tube. This irritation is much greater than that of the LMA. The irritation may cause stimulation of breathing or more likely may cause coughing on the endotracheal tube which may be counterproductive to instigating large tidal volumes. This may be more likely in those individuals with already irritated airways such as smokers or asthmatics. Combination Effects It is worth noting that upon discontinuing the volatile anesthetic, the respiratory depressing effects will start to abate as the patient rids themselves of the anesthetic. Therefore, the minute ventilation will be augmented by both the declining level of the anesthetic and the increasing levels of CO 2. A ceiling effect for respiration may occur commensurate to the amount of stimulation the patient is experiencing or the amount of opioid on board. ENSURING SAFE SPONTANEOUS VENTILA- TION Oxygenation The primary safe endpoint is that the patient maintains a tidal volume that allows for adequate oxygenation. Again, a safe tidal volume to be used in conjunction with an activated QED-100 advocated by Anecare Laboratories is at least 500 ml. If tidal volumes are less than 500 ml, special attentiveness should be paid to both the fraction of inspired oxygen and oxygen saturation. If the fraction of inspired oxygen drops below 35% or the oxygen saturation drops to less than or equal to 90%, the QED-100 should be deactivated. Without the re-breathing dead space, it may be possible that the patient may decrease his or her minute ventilation as the carbon dioxide is blown-off. Nitrous Oxide Removal If nitrous oxide is used during the case and not discontinued well before the end of the case, it may be possible for the patient to continue to rebreathe the nitrous oxide and not rapidly emerge from anesthesia, This condition may be apparent if one were to see the fraction of inspired nitrous oxide not appreciably drop on successive breaths. It should be noted that even if the fraction of inspired oxygen and oxygen saturation remains within a safe range, it may be prudent to deactivate the QED-100 after the end tidal volatile agent concentration reaches less than or equal to 1/3 of its MAC value. Again, expect that the minute ventilation may decrease. Coughing on the Endotracheal Tube If coughing due to tracheal irritation occurs, aside from being really difficult to watch, the tidal volume may suffer. In addition, since the patient is more stimulated, oxygen consumption and CO 2 production may increase. As stated above, this situation is more apt to occur in patients who are smokers or are asthmatics. It is also more apt to occur in patients who are being control ventilated. Bronchospasm, or closing of the small airways in the lungs, is more apt to occur during these coughing fits. In addition, these patients may be in stage II and are more apt to experience laryngospasm, closing of the vocal cords or airway, if the endotracheal tube is pulled too early. In this situation, it would probably be advisable to deactivate the QED-100 and allow the clinician to proceed as he or she would normally. This type of emergence may occur with or without the QED- 100 device. THE LARYNGEAL MASK AIRWAY The laryngeal mask airway (LMA) is a device that is used to help facilitate spontaneous respiration while under general anesthesia, Figure 3. While under general anesthesia with volatile or intravenous anesthetics, a patient s airway anatomy may relax and breathing may be obstructed. The LMA is a less intrusive and therefore less irritating device than the endotracheal tube. The LMA keeps the airway open by providing a direct airway conduit to the trachea but not does not extend into the trachea as does the endotracheal tube. LMA Usage The LMA may be chosen over the endotracheal tube because of its relative ease of placement, less irritability of the airway, less resistance for spontaneous breathing and therefore possibly smaller amount of anesthetic needed. Since the LMA may require less anesthetic and is not placed into the trachea, which is therefore less

QED-100 Clinical Brief Page 4 LMA Use Ease of placement Less irritation of the airway Less resistance to spontaneous respiration irritating, most anesthetists perceive that by using the LMA, patients may exit anesthesia faster. Since the LMA is considered a less adequate method to secure the airway, it will most likely only be used when the airway is more geographically accessible to the anesthetist, Figure 4. It also does not protect the airway from gastric contents like an endotracheal tube. It is also not considered to be a device of choice for positive pressure ventilation for a prolonged period of time. Therefore, it will only be used in cases in which aspiration of gastric contents is of relatively low risk, shorter cases and overall less complex surgical cases. The QED-100 with the LMA Figure 3. LMA Figure 4. LMA Use The QED-100 has been used on a limited basis with the LMA. Preliminary usage has only shown positive results. As stated above, during spontaneous ventilation at emergence, the QED-100 may be activated to facilitate emergence from a general anesthetic maintained with a volatile agent. The QED-100 will function adequately to initiate rebreathing of CO 2. This will then steadily allow the patient to increase his or her minute ventilation in response to the rise in CO 2. This increased respiration will allow for elimination of the volatile anesthetic. The QED-100, LMA and Oxygenation It must be emphasized again that tidal volumes of 500 ml are recommended in order to maintain adequate oxygenation while using the QED-100 at its maximum dead space of 750 ml. If tidal volumes are less than 500 ml, as stated above, the anesthetist must pay careful attention to the FiO 2 and oxygen saturation. Again, remember that the patient will most likely increase his or her tidal volume and or respiratory rate in response to the increasing CO 2. The QED-100, LMA and Expectations The QED-100 will help facilitate emergence of patients from volatile anesthetics while using the LMA. It is important to realize that emergence will be dependent on the amount of minute ventilation a patient is taking. This may or may not be a lot depending on factors for spontaneous ventilation as stated above. It is also important to remember that the LMA is not as stimulating as the endotracheal tube. Therefore, the emergence with an LMA most likely will be smoother than that with an endotracheal tube, but possibly not quite as rapid. CASE STUDY #1 53 year old, 75 kg, Caucasian male with history of hypertension scheduled for ORIF of left tibial plateau fracture. The patient received premedication with midazolam 2 mgs. Induction The patient was taken to the operating room. Monitors were placed. Preoxygenation occurred. The patient was induced for a general anesthetic with: 1. Fentanyl 50 mcgs 2. Lidocaine 80 mgs 3. Propofol 200 mgs After loss of consciousness, a LMA #5 was placed without difficulty. Maintenance The patient was maintained with 2.0% sevoflurane. Surgery commenced. 600 mcgs of fentanyl were titrated throughout the case. There were no difficulties and the surgery ended 3 hours later. Right before emergence, the patient was breathing at tidal volumes equal to 600 ml at 9 times per minute. His end tidal carbon dioxide was 51 mmhg.

QED-100 Clinical Brief Page 5 Case 1: 3.5 minutes Case 2: 6.0 minutes The QED-100 was activated. The patient immediately began to re-breathe carbon dioxide. The inspired anesthetic agent went to zero within 5-6 breaths. The patient progressively began to increase both his tidal volume and respiratory rate to prevent his end tidal carbon dioxide from going above 51 mmhg. His tidal volume went to 1100 ml at 18 breaths per minute. The patient was awake and had the LMA removed after 3.5 minutes. His minute ventilation right before removal of the LMA was approximately 20 liters per minute. CASE STUDY #2 42 year old 65 kg Hispanic female, otherwise healthy scheduled for ORIF of right distal radial fracture. The patient received premedication with midazolam 2 mgs. Induction The patient was taken to the operating room. Monitors were placed. Preoxygenation occurred. The patient was induced for a general anesthetic with: 1. Fentanyl 50 mcgs 2. Lidocaine 60 mgs 3. Propofol 170 mgs After loss of consciousness, a LMA #4 was placed without difficulty. Maintenance The patient was maintained with 2.0% sevoflurane. Surgery commenced. 500 mcgs of fentanyl were titrated throughout the case. There were no difficulties and the surgery ended 2 hours later. Right before emergence, the patient was breathing at tidal volumes equal to 450-500 ml at 6 times per minute. Her end tidal carbon dioxide was 47 mmhg. The QED-100 was activated. The patient immediately began to re-breathe carbon dioxide. The inspired anesthetic agent went to zero within 5-6 breaths. The patient progressively began to increase both her tidal volume and respiratory rate. The tidal volume achieved 600 ml and rate 12 breaths per minute. The end tidal CO 2 rose to 60 mmhg. The patient was awake and had the LMA removed after 6.0 minutes. Her minute ventilation right before removal of the LMA was approximately 8 liters per minute. End Notes 1. Ide K., Eliasziw M, Poulin MJ: J APPL Physiology, 95:129-137, 2003 2. Gross JB, When you breathe IN you inspire, when you DON T breathe, you...expire: new insights regarding opioid-induced ventilatory depression; Anesthesiology 2 3, Oct; 99 (4): 767-70 Anecare Laboratories, Inc. 3487 West 2100 South #100 Salt Lake City, Utah 84119 801.977.8877 www.anecare.com Anecare 2006 Printed in the U.S.A. MKT-QED100-38 Rev. Published Nov. 2006