Keofitt Aseptic Sampling Bag (Pat. pend.) Item no , & User Manual

Similar documents
KEOFITT ASEPTIC SAMPLING BAG (PAT. PEND.) Item no , & User Manual

Exploring the Properties of Gases

Exploring the Properties of Gases

INSTRUCTION MANUAL. January 23, 2003, Revision 0

abc OPERATING, INSTALLATION & MAINTENANCE MANUAL FOR MKIII CONSTANT PRESSURE CYLINDER

Exploring the Properties of Gases. Evaluation copy. 10 cm in diameter and 25 cm high)

ASEPTIC SAMPLING SYSTEM. User Manual

Neotecha Tank Sampling Sapro

Sterile Sampling Bottle Assembly

BIOCLOSURE SYSTEM ASSEMBLIES

Beamex PG PRESSURE GENERATORS. Beamex PGM PGV PGC PGHH PGPH PGL

Armatures for analytical probes

Neotecha Tank Sampling Sapro

Sterile Sampling Bottle Assembly

Neotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions

5 Gallon EVkeg Operation Manual

TUBINGS / CONNECTION PIECES

Digital Display large color coded LED display is easy to read precise measuring shows actual cuff pressure

DIAGNOSTIC CARDIOLOGY

Johnston Invar Coupling Johnston Invar Coupling

Operating instructions - Translation of the original -

UNITY 2. Uni-DAAMS Manual. Version 1.3 (Changes to Section 1.1) March 2010

VACUUM & AIRLESS. Select from Kimble vacuum traps, manifolds, Schlenk tubes, adapters, and bubblers for your vacuum and airless glassware needs.

How to use Solvent Purification System A brief manual

Thermo Scientific Chromatography Well Plates

Thermo Scientific Chromatography Well Plates

InFlow Modular perfusion bioreactor

Additel 780 Series Pressure Controller

ph measuring system for hygienic process applications

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN Original manual

[MSA The Safety Company] TURBO-FLO. Blowers. Replacement Parts. Accessories. Masks. Exploded Diagrams. safetyscope. Product Portfolio for FABA

Basic Flows in a Microfluidic Device

Training. Testor Training Manual

NeoNatalie Resuscitator Oxygen kit

AR251/AR251-B. Venepuncture and Infusion Arm. Instruction Manual

Spare parts list ( ) Spare parts list HD 1.8/13 C Ed

Model 405 &407 Small Animal Ventilator. User Manual v3.5

RayPette Plus Autoclavable Pipette. User Manual

Installation, Operation & Maintenance Manual for Flo-Max Coupler Bracket Model FM150

User Guide. Pall Laboratory Manifold. For laboratory use. Not for use in a manner other than indicated. Introduction. Regulatory References

Tentec. Instruction Document. Mini Air Driven Pump Unit Model: HTT.627X Series. Part Identifier

The NAMIC Dream Kit. Single Operator Control. Reduce Contrast Waste. Less Force to Inject. Compensator * Manifold. How the Compensator Manifold Works:

The pipettes cover a volume range from 0.1µl to 10ml.

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

Neotecha SAPRO - Tank Valve Type ST for aseptic sampling with bottles Installation, Operation and Maintenance Instruction

SESAME SAMPLING VALVE User Manual

USER INSTRUCTIONS FOR VALVES WITH MEMBRANES

NeoNatalie Resuscitator Oxygen kit

TOURNIQUET SYSTEMS & PRESSURE INFUSION

VSR modulating valves with membrane actuator

relief valves R6000 Series

CI-SfB 732 (5-1) x. - laboratory fittings

Unisense In Situ UniAmp Connector System

WELLS JOHNSON HIGH VOLUME CANISTERS

System Flow Chart. ventilation patient connection

QCS Oval. User Manual. A MODULAR QUICK CHANGE SOLUTION BY SI TECH Prepared for the ANTARES Dry Glove System. Photo: Johanna Strömgren

Procedure for Filling 2 T Bruker Magnet with Nitrogen

The University of Hong Kong Department of Physics Experimental Physics Laboratory

TOTALINE BRASS FITTINGS

User Manual MFCS TM -EZ

Type /2-Way Globe Valve 3/2-Wege-Geradsitzventil Vanne à siège droit 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

User s Guide. Vacuum Controller for liquid delivery systems

WARNING: All medications should be closely monitored to detect any alterations in the effective concentration due to the ultrafiltration process.

G7S Hand Pump Owner s Manual

Farm Chlor Chlorinator Instruction Manual

POOL ROVER ST POOL CLEANER Installation Instructions

Patients Guide for Self Administering Intravenous Antibiotics General points

Instruction Manual Updated 7/26/2011 Ver. 2.2

Valve INV-907. Instructions. 1 Introduction. 2 Installation. Safety. Unpacking. Installing the valve

Standard Flexel 3D bioprocessing bags for Palletank

EasyFit Lite Nasal Mask, Silicone. Nasal Mask. EasyFit Lite Nasal Mask. Device Description and Instructions for Use. Caution:

Haemodialysis. Bloodlines, Tubing Systems, Accessories Product Range. Product name / Headline Subline

Tourniquet Systems Pressure Infusion

Table of Contents - ALpHA Filters

Installation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Solid Indicator (Non-mixer) Model CP-30SI

1. A proper preparation of the cone and other material is inevitable prior to a CPTU test.

Operating and Safety Instructions Manual. BHS Laboratory Nutch Filter (LNF)

Flow Indicator - Measuring Device for Flow and Pressure

relief valves Circle Seal Controls 2301 Wardlow Circle Corona, CA Phone (951) Fax (951)

REL-46 WARNING NOTICE 15 TON SINGLE ACTING REMOTE HYDRAULIC CRIMPING HEAD. Compatible with RELIABLE R15 and P Style dies. REL-46 Manual

Working correctly with gas

C O L O G Y. New. g u O N. l o t a C a. The high security connection

HANDBOOK. Squeeze Off Unit SOU 400. Please refer any queries to:

Life Raft - Product Information

6900 Maintenance Instruction System Flush

Welker Constant Pressure Cylinders With Welker Solid Indicator, Syringe T-Handle, or Vortex Mixer

Flow experiment with the ibidi pump system and µ-slide I 0.6 Luer

Before you start sampling, be sure to read

Welcome to Huma-Air. We design and manufacture brand- and model specific precision regulators for PCP air rifles.

ZHE+ Zero Headspace Extractor Operation & Instruction Manual

Standard. Abdominal Aortic Aneurysm (AAA) Repair Trainer. Part No: 60610

Relief Valves. Relief Valves. International, Inc. Company ACIRCOR. RS Differential NB 9.5mm. RVA In-line Differential NB 6 to 19mm

CAM & GROOVE COUPLINGS (for Liquid, Bulk and Chemical Transfer)

GM Series Dual-Block Multi-Function Gas Control Valves

Testing Procedures & Trouble Shooting Guide Reduced Pressure Zone Assembly (1/2, 3/4", 1, 1 1/4, 1 1/2" & 2 )

Cryogenic Liquid Ultimate Liquid Cylinder Hose

Pipettor. User Manual

Additel 780 Series Pressure Controller

Vapor Pressure of Liquids

Table of Contents Categorized Listing

Transcription:

Keofitt Aseptic Sampling Bag (Pat. pend.) Item no. 120500, 121000 & 122000 User Manual s o m e p e o p l e w o u l d n t g a m B l e w i t h t h e i r s a m p l e t m

Introduction: Manufacturer: Keofitt Sampling Bags ApS Industrivænget 6-8 5700 Svendborg Denmark Type: Keofitt Aseptic Sampling Bag, item no. 120500, 121000 & 122000 Year of introduction: 2010 Year of revised design: - Manufacturer retains the right to change technical specifications and the contents of this User manual without prior notice. The English version of this Manual is the governing version and it is the only authorized version. Consequently, KEOFITT cannot be held liable for other versions including translations of this Manual.

Contents Presentation... 7 Aseptic Sampling Bag function... 8 Sterilization... 8 Accessory... 9 Part drawing Keofitt Aseptic Sampling Bag - Item 120500, 121000, 122000... 10 How to Operate:... 11

Presentation The Keofitt Aseptic Sampling Bag is a single use product. The Keofitt Aseptic Sampling Bag is a sterile, preirradiated product supplied in a sealed PE-bag. The product is to be removed from its sterile bag immediately before use. The sterile condition enables the user to extract a truly representative aseptic sample from a liquid process line sampling point in a convenient way. The Keofitt Aseptic Sampling Bag is the ultimate sampling bag solution based on Keofitt s renowned high quality and ultra hygienic sampling valve design. The Keofitt Aseptic Sampling Bag protects the sample against airborne contamination, while extracting the sample, during transportation and storage. The standard operating procedure involves steaming the sampling valve with the Keofitt Aseptic Sampling Bag connected, in order to sterilize the sampling valve and the connection between the sampling valve and the Keofitt Aseptic Sampling Bag. The 3-way valve is designed to seal off sample and ensure sterility even after valve closure. The valve sealing part is never in contact with non-sterile area. 1.Valve is steam sterilized 2. Sample is taken 3. The valve is closed and the sample is sealed and sterile During sampling the sealing area is never in contact with non-sterile areas Using standard adaptors the Keofitt Aseptic Sampling Bag becomes compatible with all small and medium sized Keofitt sampling valves. The Keofitt Aseptic Sampling Bag is used in a wide range of industries, such as breweries, dairies and the pharmaceutical and biotechnological industries. warning! During sterilization with steam the system will become hot and emits steam, care should be taken when handling the system. Use protection goggles and gloves. K e o f i t t U s e r M a n u a l P a g e 7

71 77 82 88 Aseptic Sampling Bag function The Keofitt Aseptic Sampling Bag is designed for extracting one single product sample. The design as a single use Aseptic Sampling Bag greatly reduces the risk of sample contamination occurring due to insufficient sterilization of the sample container. The Keofitt Aseptic Sampling Bag is available in 3 different sizes 500 ml, 1000 ml and 2000 ml. It is important to choose the adequate Aseptic Sampling Bag size in order not to overfill the bag. warning! An overfilled or over-pressurized Aseptic Sampling Bag may result in material burst. Pay attention to sampling process at all times. Accessory Optional: It is possible to apply a heat indicator onto the 3-way valve. The heat indicator will change colour as a function to heat vs. time. When the second dot on the heat indicator changes to black the indicator measures approx. 77 C and the corresponding steam temperature inside has been approx. 121 C for approx. 1 minute. The difference in time and temperature is due to slow heat transfer in the plastic valve material. The heat indicator can be purchased separately at Keofitt A/S; Item nr. 120055 It is very important to place the heat indicator correctly see illustration. Sterilization Sterilization is carried out by supplying steam through the sampling valve. Steam flushes through the hose piece and through the 3-way valve. The Keofitt Aseptic Sampling Bag is based on the Keofitt steam sterilizable sampling valve design. According to a test carried out by DB-Lab in Denmark steam sterilizing the connection to the Aseptic Sampling Bag becomes effective after just 1 minute s supply of steam at a pressure of 2 bar[a] (1 bar[g], 121 C). RS Important! Sterilization takes place with 3-way valve closed. 1. Open the steam supply 121 C (1 bar[g]). 2. Let the steam flow through the 3-way valve for sterilization for 1 minute. 3. Close the steam supply. Warning! The Keofitt 3-way valve and silicone hose are designed to withstand system pressure of 1 bar[g] at 121 C for 1 minute. Warning! The heat indicator will indicate a significant lower temperature on the outside of the valve than the actual temperature inside the valve. Beware of hot surface. Use protection gloves. Important! Using a heat indicator is convenient when assessing steam temperature, but should be used based on test and experience only! DO NOT AT ANY TIME APPLY SYSTEM PRESSURE ABOVE 1.5 BAR[g]! Warning! During steam sterilization the system becomes hot and emits steam. Care should be taken when handling the system. Use protection goggles and gloves. K e o f i t t U s e r M a n u a l P a g e 8 K e o f i t t U s e r M a n u a l P a g e 9

Part drawing Keofitt Aseptic Sampling Bag - Item 120500, 121000, 122000 How to Operate: Remove the Keofitt Aseptic Sampling Bag from the sealed pouch. Optional: Place heat indicator on 3-way valve. ATTACH TO VALVE OUTLET Attach the Keofitt Sterile Sampling Bag tube fitting to the sampling valve outlet sliding the blue quick coupling ring towards the valve to lock. The 3-way valve steam outlet is designed with a standard Keofitt W9 connector allowing the connection of tubing, pressure relief valve, steam trap etc. STEAM OR FLUSH STERILISATION (WARNING HOT) Steam supply is connected to the upper connection of the sampling valve and the assembly is sterilised for 1 minute 1 bar[g] (121 C). Warning! Hot. Wear goggles and gloves. REMOVE SEAL After sterilization: Break and remove the protective plastic seal preventing the valve piston from being activated unintentionally. PUSH PISTON TO OPEN VALVE Press down the piston to open the 3-way valve. Pos. Part Name Material Pos. Part Name Material 1 Tube fitting PC 6 Pinch Clamp PP 2 Quick coupling ring PP 7 Tube Silicone 3 3-way valve house PC 8 Luer Lock ABS / TPE 5 OPEN SAMPLE VALVE 4 Tube Silicone 9 Sampling Bag PE / PA 5 3-way valve piston PP / TPE To extract the sample, the sampling valve is opened slowly. K e o f i t t U s e r M a n u a l P a g e 1 0 K e o f i t t U s e r M a n u a l P a g e 1 1

6 TAKE SAMPLE Take sample Important! Do not remove steam connection from sampling valve until after sample has been extracted. 7 CLOSE SAMPLE VALVE Close the sampling valve 8 PULL PISTON TO CLOSE VALVE Pull the valve piston back up to close the 3-way valve. 9 PUSH PINCH CLAMP TO SEAL BAG Push down the pinch clamp to make the Keofitt Aseptic Sampling Bag airtight. 10 PULL QUICK COUPLING TO RELEASE Pull back quick coupling ring and remove the Keofitt Aseptic Sampling Bag. To extract test samples from the Keofitt Aseptic Sampling Bag, either penetrate the Luer lock Septum by a needle, connect a syringe to the male or female adaptor, or simply dismount the Luer lock to pour. K e o f i t t U s e r M a n u a l P a g e 1 2 K e o f i t t U s e r M a n u a l P a g e 1 3

For complete set of updated data sheets and manuals for Keofitt products please refer to our web page www.keofitt.dk