HOT SHOT OPERATING INSTRUCTIONS AND OWNER S MANUAL. Model SPC-500. (Propane Torch)

Similar documents
OPERATING INSTRUCTIONS AND OWNER S MANUAL READ AND FOLLOW ALL INSTRUCTIONS

Hotspotter. Model WB-100 Professional Series. Assembly, Testing & Operating Instructions. Safety Information:

LITTLE MAX MODEL 50G 50,000 BTU PROPANE TORCH

The following instructions were provided by the manufacturer.

Congratulations! Hand Held Torch. Warranty Policy PARTS

Owner's Manual and Instructions

WARNING: FOR OUTDOOR USE ONLY

Owner s Manual for Assembly, Operating & Maintenance of

Installation and Operation Instructions

CastCreations PRODUCT DESCRIPTION. Redwood Stump Fire Pit Item #: C1002. CastCreations Ph: Aurora, Utah

Natural Gas Conversion Kit

Please Read All Instructions and Save These Instructions For Future Reference.

INSTALLATION AND OPERATION INSTRUCTIONS

Hot Compressed Air Lance Operation Manual. LAB Manufacturing 9483 Reading Road Cincinnati, OH (800)

For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum WARNING: FOR OUTDOOR USE ONLY

Thanks for shopping with Improvements! Monterey Propane Fire Column Item #574852

A Cover 1 B Burner Assembly 1 C 1/4 Table 4 D Angle Iron 4 E Back Bracket Post (Left) H Front Bracket Post (Right) 1 J K

JACKSON GRILLS PATIO FIRE

INSTALLATION AND OPERATING INSTRUCTIONS BIG TEX VENTED GAS LOGS

Toll Free: (877) Fax: (877) TK Torch Match Lit WARNING: FOR OUTDOOR USE ONLY

OWNER'S MANUAL WARNING WARNING WARNING WARNING. Factory No.: HYFP Item No.: 67668ST

INSTRUCTION MANUAL. Models: OX2550KC WK5500OX DO NOT DISCARD THESE WARNINGS AND INSTRUCTIONS

for Assembly, Operating & Maintenance of Model Big 60 II Gas Utility Stove THIS GAS UTILITY STOVE IS DESIGNED FOR OUTDOOR USE ONLY.

Cylinder Exchange Training Manual

Safe Work Instructions For Oxygen Acetylene Equipment

CASUAL FIRESIDE A HIGHER STANDARD IN QUALITY AND APPEARANCE - SAFE AND BEAUTIFUL OUTDOOR FIRE PIT FOR PROPANE AND *NATURAL GAS

USER S INFORMATION MANUAL

Installation Instructions WARNING: WARNING: WARNING: LP AND HIGH ALTITUDE LP GAS CONVERSION KIT FOR UNITED STATES INSTALLATIONS

TK Torch Match Lit WARNING: FOR OUTDOOR USE ONLY

Natural Gas High-Altitude Conversion Kit For Installations in the United States (2,001 10,000 Feet)

OPERATING INSTRUCTIONS

INSTRUCTION MANUAL. Gas Salamander

Natural Gas to L.P. Gas Conversion Kit

CHAPTER 26 WELDING AND CUTTING

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

LP HOSE REGULATOR ASSEMBLY INSTRUCTION MANUAL. For use with Bayou Classic outdoor LP gas cookers/fryers ONLY! Do not use for any other application

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

INSTALLATION & OPERATION MANUAL FOR Teppan-Yaki Griddles

For outdoor use ONLY!

OWNERS MANUAL WARNING WARNING WARNING WARNING WARNING WARNING DANGER. Series No.: Style No.: READ BEFORE USE!

ROBERT H. PETERSON CO.

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Truck Module Page 1 of 5 Utilities Gas Emergencies Revised

INSTALLATION AND OPERATING INSTRUCTIONS

Types 749B and R130 Changeover Manifolds

INSTRUCTIONS FOR CONVERTING CONDENSING GAS MOBILE HOME FURNACES MODEL SERIES: CMA3*, CMC1*, VMA3*, VMC1*

Gas Fired Residential Heating Boilers

Composite Pistol-Type Air Needle Scaler OWNER S MANUAL

Scorched Nuts Fire Art Guide

OXY FUEL SYSTEM SET UP & SHUT DOWN PROCEDURE CHECKLIST ACETYLENE FUEL GAS

for Assembly, Operating & Maintenance of THIS GAS GRILL IS DESIGNED FOR OUTDOOR USE ONLY.

Training Program 1A Filling 1 lb. Refillable Propane Cylinders

If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

SUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide

U.S. CONCRETE, INC. SAFETY POLICY and PROCEDURE MANUAL

36H SERIES Combination Gas Valve

RE: PROPANE SYSTEM & REGULATOR TESTING/INSPECTION PROCEDURE

Operator s Manual AFA-1, AFA-2, & AFP-1 Torch Kits

OUTDOOR PROPANE FIREPIT

Gas Countertop Hot Plates

Draft. Not yet Approved

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

GEN-1e CO2 Generator OVERVIEW INSTALLATION PROPANE GENERATORS ONLY NATURAL GAS GENERATORS ONLY

Vianti Falls Fire Burner Kit (HBF16) & Propane Adapter Kit (HBF16AK) (These instructions are intended for use with a 20 lb.

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

G96 Series BASOTROL Dual Operator Valve

Fire's Edge. Fire Pit or Fire Pit Insert Model 100A-M (Manual Operation) OWNER S MANUAL / OPERATING AND MAINTENANCE INSTRUCTIONS

MATCH LIT FIRE PIT MANUAL INSTALLATION & OPERATION INSTRUCTION

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

INTENDED USE TECHNICAL SPECIFICATIONS

CITY AND COUNTY OF DENVER CR&CF RISK UNIT Compressed Gas Safety Standard

INSTALLATION & OPERATION MANUAL FOR Stockpot Range

Propane Conversion Kit Instructions

Model ASSEMBLY and OPERATING INSTRUCTIONS

Not an expected route of exposure.

OWNER S MANUAL 28" GRIDDLE COOKING STATION

WARNING: Installation Instructions. Natural Gas High Altitude Conversion Kit United States Installations Only

If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

Operator: Save these instructions for future use!

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

Important: Retain these instructions for future use.

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

SAFETY AND OPERATION MANUAL

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

Topanga Propane Fire Table Owner s Manual Small Round Style #

CNG/LPG Vehicles Emergency First Response Guide

OCBE-34-01M (P) OUTDOOR CAMPFYRE ELECTRONIC SYSTEM WITH REMOTE CONTROL

OWNER S MANUAL. Page: 1 of 8

Topanga Propane Fire Table Owner s Manual Rectangle Style # /

UNIVERSAL GAS FRYER Instruction Manual Model #8065NS

Pressure Relief Valve Instruction Manual

INSTALLATION, OPERATION, SERVICE & PARTS MANUAL FOR STOCK POT RANGE MODELS VSP100, VSP200 & VSP300

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

G92 Series BASOTROL Automatic Pilot Gas Valve

Standard Gas Countertop Griddle

GAS FRYER Instruction Manual Model #5099NS

Propane Conversion Kit Instruction

G AS BBQ GRILLS INSTALLATION INSTRUCTIONS

Phalanx Alpha Phalanx Beta and Ultra Elite

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

Operating and Maintenance Instructions

Transcription:

OPERATING INSTRUCTIONS AND OWNER S MANUAL Model # SPC-500 READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instructions in a safe place for future reference. Do not allow anyone who has not read these instructions to assemble, light, adjust or operate this tool. HOT SHOT (Propane Torch) Model SPC-500 05/13 Revision L2 #72615

FOR YOUR SAFETY! Read and understand instructions before use! Retain this information for future reference. If you smell gas: (Under certain conditions odor may fade (Refer to page 6) - Shut off gas to the device. - DO NOT try to light appliance. - Extinguish any open flame. - Check the device for leaks using soapy water. - DO NOT attempt to relight the device until all leaks are repaired and there is no gas smell. DO NOT use this device in areas where gasoline or other liquids having flammable vapors are stored or used. This device is intended for outdoor use only. NEVER direct torch flame toward hose or gas tank. DO NOT leave torch unattended while in operation. DO NOT stand or prop the torch on the burner end while in operation. Always use the striker provided. Never use a match or lighter to ignite torch. DO NOT apply heat or flame to tank to check for leaks or to increase gas pressure. DO NOT lift tank by the valve. When not in use the gas should be turned off at the LP gas tank(s). CAUTION In daylight, torch flame is barely visible. DO NOT place hand or body part in the path of the flame while lighting or operating torch. This device is designed for vapor withdrawal from an LP gas tank(s) ONLY. NOTE: Place tank on level surface in an upright position. Do not invert or lay tank on its side. Gloves should be worn at all times when operating this device. Long sleeves, long pants, and boots are recommended. Have an ABC type fire extinguisher readily accessible to the job site. THE STATE OF CALIFORNIA REQUIRES THE FOLLOWING WARNING: WARNING: Combustion by-products produced when using this product contain carbon monoxide, a chemical known to the State of California to cause cancer and birth defects (or other reproductive harm). 2 Operating Instructions and Owner s Manual

SPC-500-Parts List 1 2 3 ITEM DESCRIPTION PART NO. 1... Handle Assembly... 72601 2... Hose Assembly... 72602 3... Striker... 72603 When ordering repair parts, always furnish the following information: 1) Model Number 2) Part Number 3) Part Description Use only genuine SCHEU PRODUCTS replacement parts. Never substitute parts. Do not use modified parts. When ordering replacement parts,use the part number located in these instructions. 3 Operating Instructions and Owner s Manual

OPERATING CHARACTERISTICS Model BTU Operating Inlet Pressure Temperature Range Range SPC-500 500,000* -10 o F to 100 o F 17 psi to 170 psi * Tank size and tank temperature can directly affect BTU output Assembly Instructions: Un-assembled Assembled 1) Unpack all the components and inspect for any damage. If any damage is discovered contact the delivery service or Scheu Products immediately. 2) Connect the hose assembly to the handle assembly and tighten counterclockwise. NOTE: This is a left-handed thread connection. Connection to the Supply Tank: NOTE: The LP (Liquid Petroleum) gas tank used with this device should be no less than a 20 lb. capacity. It should also meet or exceed NFPA 58 Standard for the Storage and Handling of Liquefied Petroleum Gases. 1) Inspect the nut/nipple (excess shut-off valve) connection of the hose assembly.check for any dents or damage. The o-ring must be present. If damage is found or the o-ring is missing call Scheu Products for the proper replacement parts. 2) Connect the excess shut-off valve end of the host assembly to the shutoff valve of a LP gas tank and tighten counterclockwise. NOTE: If your LP gas tank does not have a shut-off valve, exchange the tank for one with a shut-off valve. This device is designed for vapor withdrawal from an LP gas tank(s) ONLY. Use of any other gas may result in device failure or personal injury. 4 Operating Instructions and Owner s Manual

HOT SHOT Model SPC 500 Assembly, Testing & Operating Instructions SCHEU PRODUCTS COMPANY DO NOT operate if any leaks are present. A leak may create a fire hazard. DO NOT smoke around or expose supply tank(s) to open flames or sparks. DO NOT apply heat or flame to tank to check for leaks. Excess heat may cause the supply tank to rupture, possibly causing personal injury. Lighting Instructions: NOTE: The hose assembly is supplied with an excess flow control valve. Opening the supply tank shut-off valve rapidly can cause the valve to close. If the excess flow valve closes, close the supply tank shut-off valve. Open torch adjusting valve to release any residual gas left in the hose. Close torch-adjusting valve and wait 30 seconds. Slowly open tank shut-off valve. 1) Make sure torch adjusting valve is closed. 2) Open supply tank shut-off valve. 3) With torch nozzle pointed away from any flammable material, open torch adjusting valve 1/8 th of a turn or until you can hear gas escaping. 4) Ignite using supplied igniter. 5) Use the torch-adjusting valve to control the size and heat of flame. USE: When using tool, do not direct flame directly into wind. Do not allow barrel to come closer than 6 to the surface being heated. Failure to do either of these things could cause flame outage. 5 Operating Instructions and Owner s Manual

ODOR FADE WARNING WARNING Asphyxiation Hazard Do not use this heater for heating human living quarters. Do not use in unventilated areas. The flow of combustion and ventilation air must not be obstructed. Proper ventilation air must be provided to support the combustion air requirements of the heater being used. Refer to the specification section of the heater s manual, heater dataplate, or contact the Scheu Products Company to determine combustion air ventilation requirements of the heater. Lack of proper ventilation air will lead to improper combustion. Improper combustion can lead to carbon monoxide poisoning leading to serious injury or death. Symptom of carbon monoxide poisoning can include headaches dizziness and difficulty in breathing. FUEL GAS ODOR LP gas and natural gas have man-made odorants added specifically for detection of fuel gas leaks. If a gas leak occurs you should be able to smell the fuel gas. Since Propane (LP) is heavier than air you should smell for the gas odor low to the floor. ANY GAS ODOR IS YOUR SIGNAL TO GO INTO IMMEDIATE ACTION! Do not take any action that could ignite the fuel gas. Do not operate any electrical switches. Do not pull any power supply or extension cords. Do not light matches or any other source of flame. Do not use your telephone. Get everyone out of the building and away from the area immediately. Close all propane (LP) gas tank or cylinder fuel supply valves, or the main fuel supply valve located at the meter if you use natural gas. Propane (LP) gas is heavier than air and may settle in low areas. When you have reason to suspect a propane leak, keep out of all low areas. Use your neighbor s phone and call your fuel gas supplier and your fire department. Do not re-enter the building or area. Stay out of the building and away from the area until declared safe by the firefighters and your fuel gas supplier. FINALLY, let the fuel gas service person and the firefighters check for escaped gas. Have them air out the building and area before you return. Properly trained service people must repair any leaks, check for further leakages, and then relight the appliance for you. ODOR FADING - NO ODOR DETECTED Some people cannot smell well. Some people cannot smell the odor of the man-made chemical added to propane (LP) or natural gas. You must determine if you can smell the odorant in these fuel gases. Learn to recognize the odor of propane (LP) gas and natural gas. Local propane (LP) gas dealers will be more than happy to give you a scratch and sniff pamphlet. Use it to become familiar with the fuel gas odor. Smoking can decrease your ability to smell. Being around an odor for a period of time can affect your sensitivity to that particular odor. Odors present in animal confinement buildings can mask fuel gas odor. The odorant in propane (LP) gas and natural gas is colorless and the intensity of its odor can fade under some circumstances. If there is an underground leak, the movement of gas through the soil can filter the odorant. Propane (LP) gas odor may differ in intensity at different levels. Since Propane (LP) gas is heavier than air, there may be more odor at lower levels. Always be sensitive to the slightest gas odor. If you continue to detect any gas odor, no matter how small, treat it as a serious leak. Immediately go into action as discussed previously. ATTENTION - CRITICAL POINTS TO REMEMBER! Propane (LP) gas has a distinctive odor. Learn to recognize these odors. (Reference Fuel Gas Odor and Odor Fading sections above. Even If you are not property trained in the service and repair of the heater, ALWAYS be consciously aware of the odors of propane (LP) gas and natural gas. If you have not been properly trained in repair and service of propane (LP) gas then do not attempt to light heater, perform service or repairs, or make any adjustments to the heater on the propane (LP) gas fuel system. A periodic sniff test around the heater or at the heater s joints; i.e. hose, connections, etc., is a good safety practice under any 6 Operating Instructions and Owner s Manual

DO NOT smoke around or expose supply tank(s) to open flame or sparks. Always use the striker provided. Never use a match or lighter to ignite torch. Use of device other than the striker may cause personal injury. DO NOT place hand or any body part in the path of the flame while lighting or operating torch. This can result in personal injury. Shut-Off Instructions: 1) Close torch adjusting valve. 2) Close supply tank shut-off valve. 3) Open the torch-adjusting valve briefly to release any residual gas left in the hose. DO NOT smoke around or expose supply tank(s) to open flames or sparks. Torch end of handle assembly will increase in temperature immediately after shutting off. Maintenance: Prior to each use: 1)Visually inspect all components of the device for damage and or wear. If the hose shows excessive abrasion wear, or the hose is cut, it must be replaced prior to operation. If damage is found, contact Scheu Products Co. for the proper replacement parts. 2)Visually inspect LP gas tank(s) for dents, damage to collar, damage to shutoff valveor corroded foot ring. If any of these are present the LP gas tank(s) must be replaced prior to operation. 3)Perform a leak test according to the leak test procedure described on page 5. 4)Ignite torch according to the lighting instructions described on page 5. Check operation of the adjusting valve and the other components prior to proceeding. Periodically: 1)Remove any debris or combustible material from the torch. The torch must be kept clear and free from combustible materials. 2)The surface of the device should be cleaned with soap and water. Do not use petroleum-based or flammable cleaner on any part of the device. Disconnecting the Supply Tank: 1)Make sure supply tank valve is shut off. 2)Open torch adjusting valve briefly to release any residual gas left in the hose. Close adjusting valve when complete. 3)Disconnect the P.O.L. nut/nipple located at the end of the hose assembly from the supply tank(s). 4)Replace the protective plastic cap and plug to the hose end and supply tank(s) respectively. 7 Operating Instructions and Owner s Manual

DO NOT smoke around or expose supply tank(s) to open flames or sparks. Storage: Never store a torch that is still hot. When the torch is stored indoors, the connection between the LP gas tank(s) and the device must be disconnected and the tank(s) removed from the device and stored outdoors in accordance with Chapter 5 of the Standard for the Storage and Handling of Liquefied Petroleum Gases ANSI/NFPA 58. DO NOT smoke around or expose supply tank(s) to open flame or sparks. The hose assembly shall be protected from traffic, crushing, and hot surfaces. This may cause premature wear of the hose. DO NOT lift tank by the valve. Lifting the tank by the valve may result in damage to the valve. NOTE: Storage temperature shall not exceed 120degrees F (49 degrees C). Place tank on level surface in an upright position. Do not invert or lay tank on its side. Safety Information: Safety publications related to safe practice and use: CSA 2-94 U.S. Requirements for Hand Held LP Torches for use with fuel supply ANSI Z49.1 NFPA 54 NFPA 58 Safety in Welding and Cutting National Fuel Gas Code Standard for the Storage and Handling of Liquefied Petroleum Gases 8 Operating Instructions and Owner s Manual

WARNING: OPERATING INSTRUCTIONS Model # AND OWNER S MANUAL SPC 500 USE ONLY MANUFACTURER S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH. REPLACEMENT PARTS ARE ONLY AVAILABLE DIRECT FROM THE FACTORY AND MUST BE INSTALLED BY A QUALIFIED SERVICE AGENCY. PARTS ORDERING INFORMATION: PURCHASING: Accessories may be purchased at any Scheu Products Co. local dealer or direct from the factory FOR INFORMATION REGARDING SERVICE Please call Toll-Free 800-325-7057 www.allpro-heaters.com Our office hours are 7:00 AM 4:00 PM, PT, Monday through Friday. Please include the model number, date of purchase, and description of problem in all communication. LIMITED WARRANTY Scheu Products Co. warrants its HOT SHOT to be free from defects in material and workmanship for a period of 90 days from date of purchase. Scheu Products Co.will repair or replace this product free of charge if it has been proven to be defective within the 90 day period, and is returned at customer expense with proof of purchase to Scheu Products Co. within the warranty period. Scheu Products Co. reserves the right to make changes at any time, without notice or obligation, in colors, specifications, accessories, materials and models. 9 Operating Instructions and Owner s Manual