Concentrate Distribution System (Stand Mounted) A-CDS-70-X & A-CDS-TANK-X-ST Industrial Drive, Orlinda, TN 37141

Similar documents
1020 Industrial Drive, Orlinda, TN fax

1020 Industrial Drive, Orlinda, TN fax

Universal Valve Company Inc

R E D I C O N T R O L S

Universal Valve Company Inc

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

accidents which arise due to non-observance of these instructions and the safety information herein.

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

Gas Fired Residential Heating Boilers

NGP-250/500 Nitrogen Generator Quick Start Guide

Municipal Boost w/pre-treatment Monitoring System K-A-MCB-PRE

200 PSI FAST-FILL AIR SOURCE KIT

200 PSI HIGH-FLOW AIR SOURCE KIT

Operation Manual. Carbon Filtration Industrial Drive, Orlinda, TN fax

Budget Range Operators Handbook

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

Instructions for High Altitude Conversion

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

Portable Oil Lube Air Compressors

Instructions for Cleaning & Maintaining Air Compressor

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

2 GAL AIR COMPRESSOR OPERATOR S MANUAL 1/3HP/2-GALLON IMPORTANT: READ THIS OPERATOR S MANUAL BEFORE USING

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

Installation Instructions Air Compressor Part # 2780, 2781

Freedom8 ShoeBox Compressor Manual

Booster Pump PB4-60 Replacement Kits

HPB25 Hydraulic Paving Breaker

Propane Conversion Kit Instructions

400C & 450C DUAL PERFORMANCE VALUE PACKS

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

KKT Training Series: ECO Series, Preventative Maintenance

Operation and Maintenance Manual

DPC-30 DPC-100. Reference Manual

Endo-Flush Order # ZUTR30004 OPERATION MANUAL. Zutron Medical, LLC W 98 th St #40-27 Lenexa, KS Phone Fax

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

RecoverXL and RecoverXLT Oil-Less Universal Refrigerant Recovery Systems Operation and Maintenance Manual

XpressFill XF2500 Counter Pressure Filler. Operating Instructions

Marschalk Model # 94000

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y

XpressFill XF4500C Counter Pressure Can Filler. Operating Instructions

PC1131 Electric Air Compressor

444C DUAL PERFORMANCE VALUE PACK

Pressure Dump Valve Service Kit for Series 2300 Units

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)

Installation, Operation & Maintenance Manual for Flo-Max Coupler Bracket Model FM150

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

SILENTAIRE TECHNOLOGY

IMPORTANT SAFETY INSTRUCTIONS

100C Air Compressor Kit

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

Model PSI Compressor with 3-Gallon Air Tank 12VDC

SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons

LNG Regulator Test Kit

PC 1010 Electric Air Compressor

RecoverXLT Oil-Less Universal Refrigerant Recovery System. (For serial numbers and higher)

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER COMPRESSOR For your personal safety please read, understand and follow the information provided in

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

8-gallon Air Compressor. Owner s Manual

Installation Instructions

XpressFill XF4500 Counter Pressure Filler. Operating Instructions

SILENTAIRE TECHNOLOGY

Advanced Fluid Handling Cart Owner s Manual

2 Gallon Air Compressor

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

Pressure Dump Valve Service Kit for Series 3000 Units

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

HS653 Negative Pressure Ventilation Controller

ULTRA-LIGHT DUTY ONBOARD AIR SYSTEM

RecoverXLT2-AP Oil-Less Universal Refrigerant Recovery System Operation and Maintenance Manual

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

INSTALLATION GUIDE Gas Rangetops

Refrigerant Recovery System Model 3600 Part No

Introduction. Part one: Identify the Hydraulic Trainer Components

OPERATOR S MANUAL 1.5 HP/6-GALLON 6 GAL AIR COMPRESSOR IMPORTANT: READ OPERATOR S MANUAL BEFORE USING. Toll Free Helpline:

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

Ventam 85 Installation & Commissioning Instructions

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Part IV: Troubleshooting

200 PSI COMPRESSORS - MODEL NUMBERS

Accu-Tab PowerBase 3012AT by Axiall Corporation

CART FOR CENTURION 1500+

RAM 4021 Operation Manual

Misaligned Folds Paper Feed Problems Double Feeds Won t Feed FLYER Won t Run iii

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

User Manual for the Mars Calibration Bench

4 IN. BALL LAUNCHER Engine Mounted / PTO Driven

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

MMR Air Mask With. with Quick-Connect Hose

OILLESS AIR COMPRESSOR 135 PSI

Operation and Maintenance Manual for GENTEC Model 881VR Continuous/Intermittent Digital Suction Regulators

MANUAL BE SERIES Test Benches

Types 749B and R130 Changeover Manifolds

Jacuzzi. J-CQ420 Cartridge Filter Installation and Operating Instructions

Transcription:

0 Operation Manual Concentrate Distribution System (Stand Mounted) A-CDS-70-X & A-CDS-TANK-X-ST 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax

TABLE OF CONTENTS Section 1 GENERAL 1.1 Warnings and Cautions... 1 1.2 Theory of Operation... 2 1.3 System Components... 3 1.4 System Illustration... 4 1.5 Modes of Operation... 5 1.6 Pressure Regulator Manifold (PRM)... 6 1.7 Adjust Flow of PRM... 7 1.8 Purge Air from System... 8 Section 2 SPECIFICATIONS 2.1 Requirements and Dimensions... 9 Section 3 ROUTINE MAINTENANCE 3.1 Routine Maintenance... 12 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax

Section 1.1 WARNINGS AND CAUTIONS WARNINGS Read this manual in its entirety before operating the Concentrate Distribution System. The OFF position does not disconnect power from the control box. Unplug the control box from the electrical outlet before servicing. The Manual Mode turns the pump on and it will run continuously. There is NO RUN DRY PROTECTION in Manual Mode. Misuse, improper operation, and/or improper monitoring of this equipment could result in serious injury, death, or other serious reactions to the end users of the equipment. Routine maintenance of the system is required to protect the system from tank implosion/bursting which could result in damage to the facility, injury to staff, or the end users of the equipment. CAUTIONS When used as a medical device, Federal law restricts this device to sale by or on the authority of a physician. Per CFR 801.109 (b)(1). All local, state, and federal regulations regarding the installation and operation of this system must be observed. 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax 1

Section 1.2 THEORY OF OPERATION The SWT CDS-70 is a concentrate delivery system designed specifically for delivering Dialysis Concentrate. The control box and pump are conveniently mounted on standalone stand. There are two modes of operation which are Automatic and Manual. In Automatic mode, pump run dry protection is enabled. The system may be ordered with red, yellow or orange colored labeling depicting Primary, Secondary or Tertiary. 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax 2

Section 1.3 SYSTEM COMPONENTS Control Box: Operates system through electrical relays and signals to pump. Circuit breaker protection included. Flow Switch: Monitors flow to prevent pump from running dry. Loop Shutoff Valve: Located behind flow switch. Valve must be open for pump to work. Pump: Pumps concentrate from tank through distribution loop. 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax 3

Section 1.4 SYSTEM ILLUSTRATION Control Box Label Color is related to type of system in Red, Yellow or Orange Loop Shut-Off Valve (Behind Flow Switch) Flow Switch Sample Port Distribution Pump 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax 4

Section 1.5 MODES OF OPERATION Automatic: Start / Run: Manual: Monitors the Flow Switch during normal operation and will shut pump off when a No-Flow condition occurs. Unit runs continuously in Automatic until switch is turned to the OFF position or a No-Flow condition occurs. If electrical failure occurs, push Start button to restart pump when electricity is restored. Verify all valves in distribution system are positioned correctly (V1, Open, V2 Closed) Select AUTO as Mode of Operation. Press and hold the START button until red shuttle on flow switch rises to top indicating flow is re-set. Verify all valves in distribution system are positioned correctly (V1, Open, V2 Closed) Select MANUAL as Mode of Operation. Pump will turn on immediately and run continuously. WARNING There is NO pump protection in Manual Mode 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax 5

Section 1.6 PRESSURE REGULATOR MANIFOLD (PRM) The SWT A-CDS-PRM-1-X (If Equipped) is an optional component of the concentrate delivery system. It is designed to regulate the flow of Dialysis Concentrate. The control manifold is mounted near the concentrate tank. Loop Return to Tank Loop Feed to Treatment Floor Loop Feed Pressure Gage Loop Return Flow Meter Loop Feed Regulator Valve Relief Pressure to Tank Loop Return Flow Regulator Valve Pressure Relief Valve to Tank Loop Return Pressure Gauge Pressure Relief Pressure Gage Return from Treatment Floor Supply from Pump 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax 6

Section 1.7 ADJUST FLOW Adjust Flow: 1. Unlock all three valves by pushing lock tabs INWARD to unlock position. 2. Turn all three valves counter clock wise until fully open. 3. Adjust loop feed clockwise until you have desired pressure. If more pressure is needed at loop feed adjust pressure relief valve off (clockwise). 4. Make adjustments until pressure is balanced throughout system and there is flow returning to tanks. 5. Lock all three valves by pushing lock tabs OUTWARD to locked position. Locked Position Un-Locked Position 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax 7

Section 1.8 PURGE AIR FROM SYSTEM Purging Air from System: 1. Unlock all three valves by pushing lock tabs INWARD to unlock position. 2. Ensure storage tank is full before trying to purge loop. 3. Turn all three valves counter-clock wise until fully open. 4. Turn pressure relief valve clockwise until closed diverting all pressure through the loop. 5. Let all air purge completely (Could take >30 min) 6. Purge until no sign of air is visible at flow meter 7. Use wands to purge air from patient station wall boxes (plug in each port and ensure flow is present) *Must Have Flow at Return* 8. Turn pressure relief valve counter clockwise to relieve pressure from the loop. 9. Adjust loop feed and pressure relief valves until pressure is balanced on treatment floor, ensuring you have flow to tank. 10. Lock all three valves by pushing lock tabs OUTWARD to locked position. 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax 8

Section 2.1 SPECIFICATIONS ELECTRICAL REQUIREMENTS: 120 volt AC, 15 amp circuit DIMENSIONS: Stand: 9.5 W x 16 D x 48 H 48 9.5 16 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax 9

Section 2.1 SPECIFICATIONS DIMENSIONS: Round Tank (250 Gallons Standard): 38.5 W x 48 D x 101 H w/vent Filter Square Tank (275 Gallon): 45 W x 45 D x 48.5 H (Each) Square Tank (550 Gallons): 45 W x 45 D x 56 H (Each) 101 275 Gallon 96 550 Gallon 111 48.5 56 MODELS: Round Tank A-CDS-70-R A-CDS-70-Y A-CDS-70-O Square Tank 48 45 Primary Red Tubing, Red Labeling Secondary Yellow Tubing, Yellow Labeling Tertiary/Secondary Orange Tubing, Orange Labeling A-CDS-TANK-R-ST Primary Red Tubing, Red Stand, Red Labeling A-CDS-TANK-Y-ST Secondary Yellow Tubing, Yellow Stand, Yellow Labeling 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax 10

Section 2.1 SPECIFICATIONS DIMENSIONS: 12.75 W x 19.5 H 19.50 12.75 MODELS: A-CDS-PRM-1-R A-CDS-PRM-1-Y A-CDS-PRM-1-O Primary Red Tubing, Red Labeling Secondary Yellow Tubing, Yellow Labeling Tertiary/Secondary Orange Tubing, Orange Labeling 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax 11

Section 3.1 ROUTINE MAINTENANCE Routine inspection of the system is recommended. Follow all facility procedures regarding regular inspection of electrical equipment. Quarterly system should be inspected as follows: Check all connections for leaks. Over time, varying temperature, pressure and vibration may cause some threaded connections to work loose. Retighten hand tightened connectors only by hand, and do not over tighten as this may damage the fitting(s). Unplug from wall outlet and inspect plug for signs of electrical burn. Inspect plug for frayed wires. Repair and replace as needed. Inspect and clean fan vents on control box. Ensure adequate ventilation. Wipe exterior and inspect pump for dust and debris accumulation on fan shroud. Keep fan shroud clean. 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax 12

Concentrate Distribution System (Stand) Rev. 4_2018 Manual P/N: OM-A-CDS-70-STAND