CHARACTERISTICS OF LEAK DETECTION BASED ON DIFERENTIAL PRESSURE MEASUREMENT

Similar documents
WATER HYDRAULIC HIGH SPEED SOLENOID VALVE AND ITS APPLICATION

The Estimation Of Compressor Performance Using A Theoretical Analysis Of The Gas Flow Through the Muffler Combined With Valve Motion

INSTRUMENTS A THERMAL MASS FLOW SENSOR USING A CONSTANT DIFFERENTIAL TEMPERATURE ABOVE THE AMBIENT GAS TEMPERATURE

Improvement of the Volumetric and Isentropic Efficiency Due to Modifications of the Suction Chamber

Analysis of Pressure Rise During Internal Arc Faults in Switchgear

Bubble Elimination Device in Hydraulic Systems

AIR PRESSURE CONTROLLED MASS MEASUREMENT SYSTEM

CORESTA RECOMMENDED METHOD N 6

Impact of imperfect sealing on the flow measurement of natural gas by orifice plates

TWO PHASE FLOW METER UTILIZING A SLOTTED PLATE. Acadiana Flow Measurement Society

Research and optimization of intake restrictor for Formula SAE car engine

CRITERIA OF BOW-DIVING PHENOMENA FOR PLANING CRAFT

Micro Channel Recuperator for a Reverse Brayton Cycle Cryocooler

MEASUREMENT OF GAS DISCHARGE COEFFICIENT

Mitos Fluika Pressure and Vacuum Pumps Datasheet

Using PV Diagram Synchronized With the Valve Functioning to Increase the Efficiency on the Reciprocating Hermetic Compressors

International Journal of Technical Research and Applications e-issn: , Volume 4, Issue 3 (May-June, 2016), PP.

E. Agu, M. Kasperski Ruhr-University Bochum Department of Civil and Environmental Engineering Sciences

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12

COSMO INSTRUMENTS CO., LTD.

Fire safety of staircases in multi-storey buildings The results of measurements in Buildings and Simulations

Gerald D. Anderson. Education Technical Specialist

Three Columns Gas Chromatograph Analysis Using Correlation between Component's Molecular Weight and Its Response Factor

Experimental Verification of Integrated Pressure Suppression Systems in Fusion Reactors at In-Vessel Loss-of -Coolant Events

INTERACTION BETWEEN WIND-DRIVEN AND BUOYANCY-DRIVEN NATURAL VENTILATION Bo Wang, Foster and Partners, London, UK

Test Method of Trap Performance for Induced Siphonage

Characterizers for control loops

LOW PRESSURE EFFUSION OF GASES adapted by Luke Hanley and Mike Trenary

Analysis of pressure losses in the diffuser of a control valve

Investigation of Suction Process of Scroll Compressors

SUPER PRECISION AIR RELAYS

TESTING AND ANALYZING ON P-V DIAGRAM OF CO 2 ROLLING PISTON EXPANDER

1 SE/P-02. Experimental and Analytical Studies on Thermal-Hydraulic Performance of a Vacuum Vessel Pressure Suppression System in ITER

AIR EJECTOR WITH A DIFFUSER THAT INCLUDES BOUNDARY LAYER SUCTION

WATER HYDRAULIC SYSTEM FOR HIGH SPEED CYLINDER DRIVE

Numerical Simulation for the Internal Flow Analysis of the Linear Compressor with Improved Muffler

Constant pressure air charging cascade control system based on fuzzy PID controller. Jun Zhao & Zheng Zhang

Results of mathematical modelling the kinetics of gaseous exchange through small channels in micro dischargers

Performance Analysis of a Twin Rotary Compressor

Pressure independent control valve (PICV) FLOWMATIC

SUPER PRECISION AIR RELAYS

Lesson 6: Flow Control Valves

Experimental Investigation on Transient Response of Two Stage Pressure Relief Valve

BAM - 3.2: Section Pressure Equipment Pressure Receptacles; Fuel Gas Storage Systems 26 th September 2014

THEORETICAL EVALUATION OF FLOW THROUGH CENTRIFUGAL COMPRESSOR STAGE

Effect of channel slope on flow characteristics of undular hydraulic jumps

Figure 1 Schematic of opposing air bearing concept

Pneumatic dead-weight tester Model CPB3500

MODELING OF THERMAL BEHAVIOR INSIDE A BUBBLE

Purdue e-pubs. Purdue University. Stephan Lehr Technische Universitaet Dresden. Follow this and additional works at:

Hydraulic and Economic Analysis of Real Time Control

CHAPTER 3 RESULTS AND DISCUSSION

I. CHEM. E. SYMPOSIUM SERIES NO. 85

Novel empirical correlations for estimation of bubble point pressure, saturated viscosity and gas solubility of crude oils

Increase in Evaporation Caused by Running Spa Jets swhim.com

International Research Journal of Electronics and Computer Engineering Vol 1(3) Oct-Dec 2015

REASONS FOR THE DEVELOPMENT

CHAPTER 16 %UHDWKLQJ*DV0L[LQJ3URFHGXUHV

The Discussion of this exercise covers the following points:

Effect of Inlet Clearance Gap on the Performance of an Industrial Centrifugal Blower with Parallel Wall Volute

Process Dynamics, Operations, and Control Lecture Notes - 20

67. Sectional normalization and recognization on the PV-Diagram of reciprocating compressor

Numerical Investigation of Air Bubbles Evolution and Coalescence from Submerged Orifices Based on OpenFOAM

29th Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

Transactions on Ecology and the Environment vol 12, 1996 WIT Press, ISSN

EDEXCEL NATIONALS UNIT 6 MECHANICAL PRINCIPLES and APPLICATIONS. ASSIGNMENT No. 4

living with the lab control of salinity 2012 David Hall

control of salinity Thanks to David Hall, from LWTL

Multiple Pressure Booster Systems With Variable Speed Controller Type BL

6 th International Conference on Trends in Agricultural Engineering 7-9 September 2016, Prague, Czech Republic

Organisation Internationale de Métrologie Légale

Hydraulic pressure balance Model CPB5800

628 Differential Pressure Decay Leak Tester

Validation of Custody Transfer Metering Skid at Site After Laboratory Proving

Device Description. Operating Information. CP Q (eq. 1) GT. Technical Bulletin TB-0607-CFP Hawkeye Industries Critical Flow Prover

STIFFNESS INVESTIGATION OF PNEUMATIC CYLINDERS. A. Czmerk, A. Bojtos ABSTRACT

Versions. Benefits. Balancing DN15-32 DN40 DN50 DN15, DN20, DN25, DN32, DN40, DN50. Dimensions

Gas Vapor Injection on Refrigerant Cycle Using Piston Technology

Equation 1: F spring = kx. Where F is the force of the spring, k is the spring constant and x is the displacement of the spring. Equation 2: F = mg

OIL AND GAS INDUSTRY

Thermodynamic Study of Compartment Venting

MODELLING OF FUME EXTRACTORS C. R.

DESIGN AND PERFORMANCE OF THE NEW SARTORIUS 1 KG VACUUM MASS COMPARATOR AT PTB

Hydronic Systems Balance

Updated Performance and Operating Characteristics of a Novel Rotating Spool Compressor

Investigation on 3-D Wing of commercial Aeroplane with Aerofoil NACA 2415 Using CFD Fluent

MODELING AND SIMULATION OF VALVE COEFFICIENTS AND CAVITATION CHARACTERISTICS IN A BALL VALVE

Efficiency Improvement of Rotary Compressor by Improving the Discharge path through Simulation

A New Piston Gauge to Improve the Definition of High Gas Pressure and to Facilitate the Gas to Oil Transition in a Pressure Calibration Chain

LABORATORY EXPERIMENTS ON WAVE OVERTOPPING OVER SMOOTH AND STEPPED GENTLE SLOPE SEAWALLS

Study on Intensity of Blast Wave Generated from Vessel Bursting by Gas Explosion

Laboratory studies of water column separation

Numerical simulation of the ALBA s synchrotron cooling system response to pump start-up and shut-down Page 1

Comparative Analysis of Two Types of Positive Displacement Compressors for Air Conditioning Applications

Analysis of Thermo-Mechanical Behaviour of Air Compressor in Automotive Braking System

Ideal gas law. Introduction

Properties of Fluids SPH4C

Journal of Emerging Trends in Computing and Information Sciences

Series 7250 Ruska High-Speed Digital Pressure Controller. GE Sensing. Features

Development of High-speed Gas Dissolution Device

Transcription:

CHARACTERISTICS OF LEAK DETECTION BASED ON DIFERENTIAL PRESSURE MEASUREMENT Harus L.G..*, Maolin CAI**, Kenji KAWASHIMA** and Toshiharu KAGAWA** * Graduate student of Mechano-Micro Engineering Dept., Tokyo Institute of Technology ** Precision and Intelligence Laboratory, Tokyo Institute of technology 6-853 Yokohama, Midori-Ku, Nagatsuta Chou 459 Japan (E-mail: harus@k-k.pi.titech.ac.jp) ABSTRACT This paper presents the first study on how the unbalance of temperature recovery after air charged has a significant effect on the accuracy and repeatability of air leak detection. From this viewpoint, temperature recovery time is derived and affecting parameters are investigated. In a leak detection based on differential pressure measurement, the leak is detected by measuring pressure difference between a reference component, which is leak tight, and a tested component using a differential pressure sensor. When the tested component is leaking, the pressure inside it decreases and the pressure difference with the reference is measured. However, when the required temperature recovery time is not satisfied, unbalance of temperature recovery due to a possibly small difference of heat transfer coefficient between the reference and tested component can produce pressure difference that is similar in size as a real leak and larger uncertainty. This phenomenon is described theoretically and the experimental data are in satisfactory agreement with the calculated results. KEY WORDS Air leak detection, Differential pressure, Temperature recovery NOMENCLATURE b : Critical pressure ratio [] C : Sonic conductance [m 3 /(s.pa] C p : Specific heat at constant [J/(kgK)] : pressure C v : Specific heat at constant [J/(kgK)] volume G : Mass flow rate [kg/s] h : Heat transfer coefficient [W/(m K)] κ : Ratio of specific heat [] m : Mass [kg] P : Pressure [kpa] P : Differential pressure [Pa] (P=P t -P m ) q : Volume flow rate [m 3 /s] Q L : Leak rate [cc/min] Q LG : Generated leak rate [cc/min] R : Ideal gas constant [m /(s K)] S h : Heat effective area [m ] T h : Thermal-time constant [s] T r : Temperature recovery time [s] T rr : Required temperature [s] recovery time V : Volume [cc]

: Temperature [K] : Differential temperature [K] e : Measurement error [cc/min] σ : Standard deviation [cc/min] ρ o : Air density [kg/m 3 ] Subscripts m : Master t : Tested INTRODUCTION The growing need for leak tight products has made researchers as well as leak tester manufacturer competing to develop a better leak tester. Various leak detection methods have been developed to satisfy the wide range of leak size down to 1-1 cc/min depending on the application. In a leak detection based on differential pressure measurement, leakage is detected by measuring pressure difference between a reference and a tested component using a differential pressure sensor. As compared with only measurement of pressure inside the tested component chamber, measurement of differential pressure between the dual chambers, in which a leak-tight master is used as a reference, has several advantages. The waiting time for detection can be shortened, thermal instability can be reduced and influence of external environment change can be counterbalanced. E.B. Arkilic described in his paper that temperature stability of the environment surroundings the low flow system and temperature stability within it influences the result. The more accurate the detection result and the smaller the leak size to be detected the higher the temperature stability requirement [1]. During the charging process in to a chamber, T. Kagawa demonstrated in his paper that pressure response within the chamber is affected by the heat transfer between the air in the chamber and the chamber wall []. Higher tested pressure takes longer temperature recovery time and bigger chamber volume also needs longer temperature recovery time. This must be considered when differential pressure measuring technique is going to be utilized for leak tester. When two chambers are charged simultaneously, unbalance of temperature recovery due to a small difference of heat transfer coefficient occurs and produces differential pressure that is similar in size as a real leak and uncertainty to the air leak detection. In this paper, these phenomena are analyzed theoretically and verified experimentally. MODEL AND ANALYSIS When a chamber is charged as illustrated in Figure 1, temperature inside the chamber increases to a certain level and recovers to atmosphere temperature due to heat transfer. And when the charging process is stopped during temperature recovery, the pressure inside the chamber decreases proportionally to the temperature change within the chamber [3]. To describe this phenomenon, first, the ideal-gas equation of state is derived as follow: dp P dθ = + G (1) θ V From the conservation of energy, the following equation is obtained: d C m θ v = CvGu ( θ a θ ) + RGuθ a + Q () As the atmosphere temperature is maintained constant at a certain level a, the heat transfer rate passing through the chamber wall can be expressed as: q=hs h ( a ) (3) Based on Eq. (1), Eq. () and Eq. (3), the pressure and temperature change inside the chamber after charging process, can be expressed utilizing the following equations: dp P dθ = + G (4) θ V [ G( C θ C θ ) + hs ( θ θ )] d θ = (5) p a v h a C PV v Where the mass flow rate to the chamber is expressed as [4]: P b P s P Cρ op 1 >... b (6) 1 b = P G s P Cρ op... b Ps P s a q P, V,, h Figure 1 Air charged in to a chamber

P s P s P m, V m, m, h m a q P t, V t, t, h t q Figure Air charged simultaneously to two chambers The simulated results of pressure and temperature change within the chamber after stop charging at 6s, under pressure 5kPa and chamber volume 14cc are shown in Figure 3. As illustrated in the figure, the pressure within the chamber decreases as a result of temperature recovery. In a differential pressure type air leak tester as displayed simply in Figure, two chambers are charged simultaneously to supply pressure before starting leak detection. After charging process is stopped at T r = 6s, to start leak detection, temperature difference due to inadequate temperature recovery produces differential pressure that is similar in size as a real leak even though tested chambers is leak-tight. These phenomena are demonstrated theoretically in Figure 4. As illustrated in the figure, although the heat transfer coefficient is only.6% different between master and tested chamber, a.1k remaining unbalance of temperature recovery occur at this point due to inadequate temperature recovery time and this produces a pressure difference of 6Pa even though tested tank is leak-tight. When the charging is stopped at a longer time (i.e. 1s), the pressure difference becomes about 3.5Pa. It is clear that longer waiting time is necessary to create adequate temperature recovery and to eliminate the pressure difference not due to leak. Leak size for dual chamber method is simply calculated based on the derivation of ideal gas equation: Vt dpt Vm dpm PV t t dθt Pm Vm dθ m = ρql + (7) t m If the two chambers are equal in temperature, volume and undergo identical thermal fluctuations, then the leak rate is given by: Q L t V d P PV dθ = (8) m P [Pa] [ 1 5 ] 6 5 4 3 1 36 34 3 3 5 1 15 Figure 3 Pressure and temperature inside the chamber [Charging is stopped at 6s] P [Pa].1 -.1 1 : 6s : 1s 5 1 15 Figure 4 andp change between the two chambers [h =3W/(m K), h t =3.8W/(m K)] Generally, the last part of Eq. (8) can be neglected since P and dθ is very small as compared with. LEAK DETECTION The developed leak tester The developed leak tester as illustrated in Figure 5 consists of 5 main elements: PLC (Programmable Logic Controller), PC (Personal Computer), a reference and tested component, a differential pressure sensor and valves. The valves are controlled by the PLC based on the sequence as displayed in Figure 6. The room temperature is maintained constant at o C. The applicability under high pressure and the leak-tightness of the leak tester before utilizing for leak detection are important to be guaranteed. By disassembling both master and tested chamber, the leak tester is charged up to 8kpa.

Figure 5 Developed leak tester At the possible shortest temperature recovery time 6s, the charging is stopped and the differential pressure response between reference and tested circuit is recorded, and repeated 5 times under the same experimental condition to guarantee the repeatability of the leak tester. As illustrated in Figure 7, the differential pressure responses after the charging process is stopped at 6s are stable, constant at zero level and high repeatability. The experimental result demonstrates the applicability of the developed leak tester under high pressure, pressure balance between reference and tested circuit, and the leak-tightness of the leak tester. Characteristics of leak-tight chamber As demonstrated in the simulated results that inadequate temperature recovery can produce pressure difference that is similar in size as the real leak although tested chamber is leak-tight. The experimental results, as displayed in Figure 8(a) and 8(b), are carried out under leak-tight tested chamber, 5 times repetitions and in two different T r (i.e. 6s and 1s). The results are in satisfactory agreement with the simulated results. Since the charging process passing through a sudden enlargement from the pipe to the chamber, the experimental results also show the effect of inadequate temperature recovery to the range of uncertainty as demonstrated in Figure 8. Within 5 sample data, the range of uncertainty of the differential pressure response due to inadequate temperature recovery is larger when shorter T r is applied. Leak generation and detection results As displayed in Figure 5, leakage is generated by a variable restrictor attached to the tested chamber. The generated air leak is measured by a mess cylinder filled with water connected at the end of the pipe. Charge 1st Running ON Detection OFF.5s Charge nd Running.5s Detection Figure 6 Valve control sequence A B C D Discharge Figure 7 P response of leak tester Based on the JPAS-1984 standard for air leak measurement, the generated leak rate is the ratio of the collected air volume due to leakage in the top of the mess cylinder to time consumption t during leak detection.

P [Pa] P [Pa] P [Pa] P [Pa] Figure 8 Simulated and experimental results of the P responses for leak-tight tested chamber, Experiment is carried out 5 times, P=5kPa and V=14cc: [a]t r =6s and [b] T r =1s Figure 9 Differential pressure change under 5 times repetitions for.3cc/min generated leak from tested chamber for P=5kPa and V=14cc: [a]t r =6s and [b] T r =1s The experiment on leak tested chamber was carried out by generating.3cc/min leakage from the tested chamber and five sample data were recorded at each temperature recovery time to investigate the repeatability of the detection results. The experimental results are summarized in Figure 9(a) and 9(b) for T r =6s, and 1s respectively. Figure 9(a) demonstrates that inadequate temperature recovery produces larger uncertainty or low repeatability which is shown by about 4Pa range of uncertainty of the differential pressure P change within 5 sample data due to.3cc/min generated leak. However, when the temperature recovery time T r is set to be longer (T r =1s), the differential pressure P response varies narrowly about 4Pa as demonstrated in Figure 9(b). Table 1 displays the summary of the precision and accuracy of the detection results in various T r and leak sizes which are indicated by the measurement error e and the standard deviation respectively. REQUIRED TEMPERATURE RECOVERY The uncertainty of the differential pressure responses for leak-tight tested chamber in various pressures and volumes are summarized in Figure 1. Table 1 Measurement error and deviation (a) P=5kPa and Q LG =.3cc/min T e σ 6.4.1 1.. 14.1.1 (b) P=5kPa and Q LG =.5cc/min T e σ 14.4.1 18.1.6.1. The experiments were carried out by taking the maximum range of uncertainty within five sample data for various pressures (i.e. kpa, 5kPa and 8kPa), various volumes (i.e. 14cc and 4cc) and 4s time increment (i.e. 6s, 1s, 14s and 18s).

5 4 3 1 5 4 3 1 5 1 15 5 3 T r [s] Figure 1 Range of uncertainty in various pressures Higher accuracy requires lower uncertainty and a.1cc/min of accuracy requires less than 1Pa and 35Pa tolerable range of uncertainty of the differential pressure response for chamber volume 14cc and 4cc respectively. The required temperature recovery time T rr is defined as the minimum temperature recovery time that can produce range of uncertainty less than 1Pa and 35Pa for chamber volume 14cc and 4cc respectively which is shown by the solid line in Figure1. And the experimental results of the T rr are summarized in Figure 11 upper side. It is clear that T rr depends on the charged pressure and chamber volume.however, it is difficult to determine it by drawing the curve of uncertainty as shown in Figure 1, since it takes long time to conduct experiments under different T r. Here, we disscus the relation between T rr and the thermal time constant. The thermal time constant is defined in the following equation [5]. rr rr 16 1 8 4 8 4 6 8 1 6 4 14cc 4cc P [kpa] 4 6 8 1 Figure 11 Required temperature recovery and thermal-time constant Temperature recovery and its unbalance due to a small difference of heat transfer are discussed. This unbalance and inadequate temperature recovery produces differential pressure between master and tested chamber though the tested chamber is leak tight. Furthermore, this differential pressure is uncertain due to uncertainty of heat transfer. Due to the difficulty of determining the required temperature recovery time experimentally, its relation with thermal time constant has been investigated and proposed in this research to be utilized to estimate the required temperature recovery time that is very meaningful in leak detection field. REFERENCES CvW CvPV Th = = (9) S h S h h Because T rr is also a parameter proportional to the charged pressure and related to chamber volume as shown in Figure 11 upper side, we calculate their ratio and show the result in Figure 11 lower side. It can be seen that the ratio is less than 6. Therefore, as a practical determination method, the required temperature recovery time can be approached by setting 6 times of the calculated thermal time constant for various pressures and volumes. CONCLUSIONS A differential pressure type air leak tester is studied. h 1. Arkilic, E.B., Schmi, M.A. and Breuer, K.S., Sub-nanomol per second measurement near atmospheric pressure, Journal of Experiments in Fluid, 1997, Vol., pp.37-41.. Kagawa, T., Shimizu, M. and Morita, Y., Heat conduction effects of the chamber wall on the air pressure dynamics, Proceeding of Measurement and Automatic Control Association, 1987, Vol.3, No.8., pp.87-871. 3. Incropera, F.P. and Dewitt, D.P., Fundamental of Heat and Mass ansfer, 4 th edition, John Wiley & Sons. 4. ISO6358: Pneumatic Fluid Power-Components Using Compressible Fluids-Determination of Flow rate Characteristics 5. Kagawa, T. and Shimizu, M., Non dimensional Pressure Responses of Pneumatic RC Circuit Considering Heat ansfer, Proceeding of Hydraulic and Pneumatic, Vol.19, No.4, pp.36-311.