Inflatable Stretcher. Product Manual

Similar documents
Evacuation Raft. Product Manual

RS5 & RS6 Rescue Sled. Product Manual

RS3 Rescue Sled. Product Manual

Rapid Response Shelters. Rubber Product Manual

SMA1500 Instructions for Self Inspection SMA MANUAL INFLATION SMA AUTO INFLATION

SMA1060 INSTRUCTIONS FOR SELF INSPECTION SMA1061 MANUAL INFLATION SMA1062 AUTO INFLATION

NATIONAL (NATO) STOCK NUMBER: NSN

CREWFIT 165 SPORT. self care and maintenance manual

INFLATABLE RESCUE RAFT 4 MANUAL

Rapid Survival System

IMMERSION SUIT MAINTENANCE GUIDE IMMERSION SUIT MAINTENANCE GUIDE 1409 SERIES. SCMG003A Maintenance Guide - Immersion Suits USA ENGLISH.

Owner s Manual. MD3196 and MD3091 Compact Tactical Life Preservers. *Shown with the MA3090 Chest Belt/Crotch Strap Assembly

ALPS Flotation Collar. User s Manual

SPUD OWNER S MANUAL ALWAYS WEAR A COAST GUARD APPROVED FLOTATION DEVICE WHEN OPERATING THE SPUD KAYAK.

Hammar LifeJacket Inflator

J800 HOPE BUOYANCY COMPENSATOR OWNER S MANUAL

airo-double-naut inflatable kayak made by

Usage and Care Instructions

ExtendAire TM II. Intermediate Pressure Accessory Kit USER INSTRUCTIONS

Assembly Instructions. for. Puffin Saranac. ScanSport, Inc. P.O. Box 700 (234 May Street) Enfield, New Hampshire Phone: (603)

NORTHERN DIVER PFD MANUAL

SMA2100 Series CONSTANT WEAR LIFE PRESERVER VEST (CWLP) SMA2160 OWNERS MANUAL

LTS BCD USER GUIDE. Hollis (2014) Doc r01 (8/29/14)

LEAK SEALING SYSTEMS


AIR LIFTINGBAG OPERATIONGUIDE. BasicSafelVPrecautions Equipment Description OperatingInstructions - Applications.

OWNER S MANUAL AirTop Large and AirTop Small

THIS CARD IS MAINTAINED TO PROVIDE PROCEDURAL TEXT ONLY AND IS NOT REPORTED TO ACMS

THE OWNER'S MANUAL IS IN TWO VOLUMES: VOLUME 2 TECHNICAL SPECIFICATIONS - ASSEMBLY PROCEDURE ZODIAC

20 Ton SD Shop Press Operating Instructions

PFD 1 275N INFLATABLE JACKET

PNEUMATIC MEDIUM PRESSURE HEAVY LIFTING BAGS

IMPORTANT SAFETY INSTRUCTIONS. PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE SETUP AND USE. KEEP THESE INSTRUCTIONS IN A SAFE PLACE FOR FUTURE

Cimarron Pontoon Boat

SLIDE. Super Sweet. instruction manual SLIP SLIDE SPLASH INFLATE THE FUN WITH THINGS YOU NEED TO KNOW ABOUT THE SUPER SWEET SLIDE.

INSTRUCTION MANUAL. Featuring - Quick Burst Zipper Survival Operations Specialist SOLAS (74/96) Approved Lifejacket

ANNUAL SELF INSPECTION / SERVICING INSTRUCTION SHEET

aironaut inflatable kayak made by

Air-Shelters INSTRUCTION MANUAL UPDATED: 10/15/04. This manual is for ZUMRO Shelter Models: 150, 216, 284, 311 & 400

OWNER S MANUAL ALWAYS WEAR A GOVERNMENT APPROVED FLOATATION DEVICE WHEN FISHING. Know the limits of your ability and the limits of your equipment.

Instruction & Maintenance Manual for Slix 100 Stretcher

MMR Air Mask With. with Quick-Connect Hose

Inflatable Dock Slide Owner s Manual

30T A/Manual Hydraulic Shop Press

Spray N Splash JUNGLE FUN POOL

User manual STARLOCK. Careways International - Innovation Quality Performance

Product Information News

LPU- 40 Flotation Collar

SOS DAN BUOY DON T BE SECOND BEST INSTRUCTION MANUAL WHEN THE SECONDS COUNT READY TO GO MAN OVERBOARD RESCUE MARINE DESIGNED BY SOS MARINE, AUSTRALIA

Service Manual. Mullion Hi-Rise 275N SOLAS dot twin chamber lifejacket with Hammar hydrostatic mechanism.

MD5183 ELITE INFLATABLE PFD

Height Safety Lifting Load Control

CBP LPU- 40 Flotation Collar User s Manual

PETERSEN 161-SERIES HIGH PRESSURE LIFTING AIR BAGS OPERATING INSTRUCTIONS WARNING!

Operator s Manual. with Maintenance Schedule. Fourth Edition Second Printing Part No

Sea Rebel Kayak Owner s Manual

SMA1060 OWNERS MANUAL

Combination Breathing Apparatus

DO NOT REMOVE PRIOR TO SALE! OWNER S MANUAL for Model No. 1212

Toileting Sling Plus

Product Information News September 26, 2003

REL-510H WARNING NOTICE 12 TON SINGLE ACTING REMOTE HYDRAULIC CRIMPING HEAD

Owner's Manual SMA2000 Series

Inflatable PFD Owner s Manual

DO NOT REMOVE PRIOR TO SALE! OWNER S MANUAL for Model 33M42-V17

DO NOT REMOVE PRIOR TO SALE MD1250

Products For The. Fire & Emergency Services. Cintec International Limited

Puffin Sport and Saco

Island Hopper Gator Monster Head & Tail Water Trampoline Attachments


Handle the film very carefully. As with aluminum foil, once creased, the film will remain creased.

MD3183 / Hydrostatic Inflation Model / Manual with Automatic Backup USCG Approvals: Recreational: Type II Uninspected Commercial Vessels: Type V

Owner s Manual. Water Sports Equipment

* * * SAVE THIS MANUAL * * *

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

OWNERS MANUAL FOR MODEL TD2401 Inflatable Throwable Device (Type IV PFD).

BUOYANCY COMPENSATOR DEVICE MANUAL

FOR MODEL NUMBERS MD2981 (MANUAL) / MD2983 (AUTO) OWNER'S MANUAL DLX 38 INFLATABLE PFD

75 Ton SD Shop Press Operating Instructions

275 RID Assembly Instructions

Owner s Manual. MD Inflatable Vest with LIFT TM Hydrostatic Inflation Model - Manual with Automatic Backup

B.C.D. Buoyancy Compensator Device User Manual

REL-46 WARNING NOTICE 15 TON SINGLE ACTING REMOTE HYDRAULIC CRIMPING HEAD. Compatible with RELIABLE R15 and P Style dies. REL-46 Manual

The Service label can be found

The Legendary Performance Kurrent

WE SAVE LIVES FOR A LIVING

Owner s Manual. MD3085 Inflatable PFD Manual Inflation Model Recreational: USCG Approved Type III Uninspected Commercial Vessels: USCG Approved Type V

Tactical Flotation Support System (TFSS) User s Manual

WATER SLIDE. Limbo Beach

Owner s Manual RESCUE STICK TM MRD100 THROWABLE EMERGENCY RESCUE INFLATABLE

DO NOT REMOVE PRIOR TO SALE! OWNER S MANUAL

Travel Wing. Buoyancy Compensator User Instruction Manual

Aqua Tower Slide Owner s Manual

DO NOT REMOVE PRIOR TO SALE! OWNER S MANUAL for Model 24MSPT-1

Maintenance and Repair. AirHawk II Air Mask. Second Stage Regulator. Order No.: /02 Prnt. Spec (I) MSAsafety.

Puffin Sport Assembly and User Information

12 Saturn Owner s Manual

AUXILIARY ACR PLB Monthly Inspection and Test For use by Auxiliary members issued ACR PLBs within District Eleven North Revised Jan 2016

* * * SAVE THIS MANUAL * * *

ANNUAL SELF INSPECTION AND SERVICE INSTRUCTIONS

Transcription:

Inflatable Stretcher Product Manual MFC International 2017 1

Index Technical Data / Capacity Parts Parts List Materials List Operational Instructions Packing Storage Maintenance & Test Procedures Repairs 3 4 5 6 8 8 9 10 WARNING: Carefully read this manual before operating the Inflatable Stretcher NOTICE: The manufacturer takes no responsibility for the consequences of actions not complying with the instructions given in this manual. 2 MFC International 2017

Technical Data Product Code No. of persons 1 Length (cm) 203 Inflatable Stretcher WR0196 Width (cm) 69.5 Height (cm) 6.7 Capacity (kg) 150 Air Requirements (ltr) 100 Pack size (cm) Weight (kg) 6.5 Working Pressure (bar) 0.5 35x35x18 Recommended regulator Type 855 8 bar MFC International 2017 3

Parts List 4 MFC International 2017

Item Description 1 Inflatable Bed Neoprene coated drop thread - Black Hypalon coated polyester - Black 2 Inflate/deflate valve Leafield C7 - Black Acetal. 3 Relief Valve 0.41 Bar Leafield A6 - Black Acetal. Materials List 4 Carrying Handle Hypalon coated polyester - Yellow, webbing strap with moulded rubber handle 5 Chest restraining strap 3.8cm polyprop webbing - Red ISO 12402-7 S/R buckle - Black 6 Leg restraining strap 3.8cm polyprop webbing - Red ISO 12402-7 S/R buckle - Black 7 Foot securing strap 3.8cm polyprop webbing - Red, 316 S/S buckles 8 Label, Inflate / Deflate Yellow vinyl, digitally printed 9 Label, Relief Valve Yellow vinyl, digitally printed 10 Label, MFC logo White vinyl, digitally printed 11 Label, Recovery board data White vinyl, digitally printed 12 Rucksack PVC coated polyester Orange Straps Polyester webbing 13 HP Inflation hose 1.0m reinforced hose c/w C7 valve adaptor 14 Repair kit 70ml.tube Neo. Adhesive, Hypalon patches x4 MFC International 2017 5

Operational Procedures 1. INFLATION 1.1. At deployment point, select best possible flat debris-free site. 1.2. Unpack the Inflatable Stretcher from its rucksack and unroll. 1.3. Prepare for Inflation:- a) Fix Regulator to cylinder(s) and connect delivery hose to Regulator. b) Remove dust cap from inflation valve in the inflatable bed, ensure the central valve diaphragm is closed; i.e. the internal spindle is raised. (push and turn to release). NOTE: The Inflatable Stretcher is inflated through the inflation valve located at the feet end of the bed. (see pg. 4) 1.4. Hold delivery hose tight into inflation valve. Open cylinder valve and inflate until relief valve activates. (see pg.4 item 3) Close cylinder valve. Do not release hose during inflation. WARNING: Failure to do this may result in personal injury to the operator. 1.5. Ensure dust cap is replaced to prevent ingress of dirt and water. 2. DEPLOYMENT & USE The following points are operational recommendations established by deploying the Inflatable Stretcher at different training and demonstration events. MFC acknowledge that almost every operational scenario will have different hazards and risks, which can only be properly assessed at, and during, an operational rescue/recovery. WARNING: during use near water, mud and suspect surfaces, personnel should wear a Lifejacket or appropriate buoyancy aid. Failure to do this may result in personal injury or death. 2.1 Body restraining straps - The casualty should be strapped onto the Inflatable Stretcher during transportation using the 2 diagonal chest restraining straps and the leg restraining strap. (see pg.4 items 5 & 6) All straps must be tightened to secure the casualty. To undo the straps press the red button located on the side of each buckle. CAUTION: Ensure that the two parts of the buckles are pushed together and securely locked (audible click) before moving the casualty. 6 MFC International 2017

2.2. Foot securing strap - The foot securing strap is fitted by placing the webbing loops over the feet. The continuous strap goes over both insteps and the short strap forms two loops that go under the soles of the feet (see pg.4, item 7). The strap must be adjusted equally at each end to secure the casualties feet in the centre of the Recovery board. 2.3 Carrying handles - The Inflatable Stretcher should only be carried by using the moulded handles provided on each side. (see pg.4 item 4) CAUTION: Ensure that the Inflatable Stretcher is lifted evenly to prevent further possible injury to the casualty. MFC International 2017 7

Packing 1. Lay the Inflatable stretcher on a clean, debris free area. 2. Deflate the Inflatable stretcher. This is achieved by depressing the central spindle in the inflate/deflate valve, (push and turn to lock open). (see page 4, item 2). 3. Roll from the head end towards valve to expel the air. 4. Un-roll the Inflatable stretcher to its full length once again. Fold in half length ways and flat roll towards the valves, taking care to maintain the width of the roll. 5. Lay the rucksack face down on the ground, place the rolled Inflatable stretcher in the centre, tightly overlap the sides and secure using the velcro straps. Lift the bottom flap (webbing straps) up and over, tucking in both corners. Do the same with the top flap, secure the webbing straps through the buckles and tighten. Storage 1. On return to base the Inflatable stretcher should be unpacked, inflated, thoroughly washed to remove contaminants and left to dry. 2. When the Inflatable stretcher is completely dry it and its associated equipment should be checked for wear or damage. If none is found it should be repacked in its rucksack. 2.1. If any damage is found it should be repaired or replaced immediately in accordance with the Repair instructions. 3. Where possible the packed Inflatable stretcher should be stored so that no damage can be caused by it s proximity to other items of equipment. 8 MFC International 2017

1. GENERAL Maintenance & Test Procedures It should be noted that, due to the type of fabrics used in its construction, when the Stretcher is wet, there may sometimes be visual evidence of miniscule white bubbles, which form a line of froth at the seams and joints of the unit. This is recognised within the industry as lateral leakage, and is simply air that is trapped in the layer of nylon between the rubber coatings, forcing its way to the nearest available edge of the fabric. This type of leakage will not affect the performance of any inflatable product over the course of an operational procedure, and can be safely ignored. However, if there are larger, transparent bubbles, this is clearly evidence of a leak that must be repaired at the earliest convenience. The following is a recommended regime for maintenance & test. 2. QUARTERLY 2.1. Check control equipment as per relevant manual. 2.2. Inflate Inflatable Stretcher to working pressure. 2.3. Check audible relief valve operation. 2.4. Whilst inflation system is charged, check connections and valves using brush and soapy water. 2.5. When relief valve has operated, and the unit is at working pressure; it can be left to stand for a length of time that would be comparable to an operational situation (e.g. 2 to 3 hours.) 2.6. After this time, the Inflatable Stretcher should still be firm. 2.7. If the Inflatable Stretcher has become soft, the air-loss should be located by applying a soapy- water solution. 2.8. Any significant leaks (See 1 above) should be marked and repaired using the repair kit provided. RECOMMENDATIONS 1. The Inflatable Stretcher and its associated equipment should undergo an annual test carried out by the manufacturer, or persons certified by MFC International Ltd. If in doubt contact the service department. 2. The Inflatable Stretcher should be inspected and tested in accordance with relevant International, European or National standards and appropriate records maintained throughout its operational life. MFC International 2017 9

Repairs As a general rule, punctures and other damage will need to be assessed in two categories: a) that which is repairable at the base, or b) serious damage that will need to be repaired by MFC International Ltd. a) Repairs that are manageable at the base workshops will be minor punctures to any area of the Rescue sled. These can normally be repaired by the application of a small repair patch. b) Repairs that should be carried out by MFC will be the more serious kind, such as damaged valves, badly torn fabric (either on the sidewalls or the flat surfaces) and the replacement of damaged fittings. If in doubt as to the extent of the damage and the level of repairs necessary, please contact :- MFC International Naval Yard Tonypandy Rhondda Cynon Taff CF40 1JS T. +44 (0) 1443 433 075 F. +44 (0) 1443 420 448 sales@mfc-international.com www.mfc-international.com A Respirex International Limited Group Company 10 MFC International 2017

MFC International 2017 11

MFC International Naval Yard Tonypandy Rhondda Cynon Taff CF40 1JS T. +44 (0) 1443 433 075 F. +44 (0) 1443 420 448 sales@mfc-international.com www.mfc-international.com A Respirex International Limited Group Company SA-MA57-02