HPFM GEN3 - High Pressure Flow Meter

Similar documents
High Pressure Flow Meter Installation and Operations Manual

Automatic Isokinetic Sampler. ST5 Evo

Additel 761 Automated Pressure Calibrators Selection Guide

Automatic Isokinetic Sampler. ST5 Evo

Additel 761 Automated Pressure Calibrators Selection Guide

Oxidation Stability of Gasoline and Aviation Fuels

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

Additel 761 Automated Pressure Calibrators

Lab 1: Pressure and surface tension. Bubblers, gravity and the mighty paper clip.

Additel 761 Automated Pressure Calibrators

Transpiration. DataQuest OBJECTIVES MATERIALS

Lab 4: Transpiration

Additel 761 Automated Pressure Calibrators

Lab 1c Isentropic Blow-down Process and Discharge Coefficient

Benefits. Rev.III_032018_Oxybaby 6.0_engl subject to technical alterations

Triaxial automated systems

MACH ONE MASS FLOW CONTROLLER. MACH ONE SERIES flow control. MASS FLOW CONTROLLERS at the speed of sound.

Lab #1 Pressure: Bubblers and Water Balloons CEE 331 Fall 2003

OXYBABY - MOBILE HAND HELD GAS ANALYSER

PMI Pulse Decay Permeameter for Shale Rock Characterization Yang Yu, Scientist Porous Materials Inc., 20 Dutch Mill Road, Ithaca NY 14850

AUTOMATIC HOSE TEST UNIT, TYPE SPU

GAS ANALYSER OXYBABY 6.0 for O 2. or O 2 /CO 2

Pressure calibration. 20

Vapor Pressure of Liquids

Additel 780 Series Pressure Controller

DataCan. Linewise System. Description. Hardware. Applications

NT High-temperature flowmeter model Simultaneous flow and pressure outputs for high-temperature applications

Additel 780 Series Pressure Controller

_ pressure transducers. User Manual

THE MARKET LEADER IN CAPILLARY FLOW POROMETRY CFP1

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

Cover Page for Lab Report Group Portion. Pump Performance

Cover Page for Lab Report Group Portion. Head Losses in Pipes

AIR-X COMPACT AIR-X ON-LINE LUBRICANT AERATION MEASUREMENT. Technical Brochure ON RUNNING ENGINES

QUANTIFIT....the gold standard in respirator fit testing. Product Information Brochure

Spindles AISI 316 stainless steel spindles, easily identified by number and letter when changed according to range of viscosity.

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.

ADT 761 Automated Pressure Calibrator

Beamex PG PRESSURE GENERATORS. Beamex PGM PGV PGC PGHH PGPH PGL

Pneumatic dead-weight tester Model CPB3500

PRESSURE SENSOR - ABSOLUTE (0 TO 700 kpa)

GAS ANALYSER OXYBABY 6.0 for O 2. or O 2 /CO 2. premium version

29 Pressure, Temperature relationship of a gas

Experiment 11: The Ideal Gas Law

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

PRESSURE-TEMPERATURE RELATIONSHIP IN GASES

F&J SPECIALTY PRODUCTS The nucleus of quality air monitoring programs

PPC4E Pressure Controller/Calibrator Superior rangeability and reliability

Application Note AN-107

Pressure Calibration. Technical Data. Pressure Calibration with Fluke Calibrators

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

Lab #12:Boyle s Law, Dec. 20, 2016 Pressure-Volume Relationship in Gases

WL16 WATER LEVEL LOGGERS Submersible pressure transducer and USB datalogger combination

AMS 2710 PCB pressure sensor module with V output

Additel 780 Series Pressure Controller

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L

General Specifications: Forensic. Petrochemical Environmental. Lab Quality Analyses in the Field, It Goes with you Anywhere!

Series Environmental Chambers

FlexAct BT (Bag Tester) Validation November, 2015

Experiment C-6 Gas Solubility

AIR FLOW CALIBRATORS Single Sensor Designs

AMS 6915 Board mount pressure sensor with digital output (I²C)

User Manual Pressure Calibration System C and Hydraulic Pressure Pump Models T-620/T-620H Copyright 2008 AMETEK Denmark A/S

Hand-held pressure calibrator with integrated pump Model CPH6600

Oil Diagnostic Systems. Online and bottle measurement Mobile and stationary operation Lab quality accuracy e

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

Digital deadweight tester Model CPD8500

Model PDT Dewpoint Transmitter

PRODUCT DATA SHEET. Description

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

Environmental Petrochemical, Pharmaceutical, Foods & Flavors, Chemicals, Personal Care, Forensics,...and more!

Fluke 700 Series pressure modules

CO 2. (R744) Service Station Presentation. Contents. Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype

The Discussion of this exercise covers the following points:

FPG8601 Force Balanced Piston Gauge

Precision and Instrument Regulators 1/4" port size

PRESSURE COMPARATOR 10000PSI 700bar. Operator Instructions CRYSTAL. engineering corporation


The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Pneumatic high-pressure controller Model CPC7000

Experiment P18: Buoyant Force (Force Sensor)

Specifications for the CMI 2409 Magnetocardiograph

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

TR Electronic Pressure Regulator. User s Manual

EPP4 Pressure Regulator Basic G 1/4"

Expert Hydrostatic Level Transmitters

RD(H)20/25 Pressure-Reducing Regulator User Manual

Precision digital pressure gauge Model CPG1000

MCQ Gas Blender 100 Series 3 Channels Gas Mixer

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

D-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA

Constant Pressure Inlet (CCN) Operator Manual

RM-80 respiration monitor

MET 335W Fluid Mechanics Laboratory. Lab 1: Bourdon Tube Calibration. Nick Peak

159 mm 154 mm. Subject to changes 10/2012

HumiSys HF High Flow RH Generator

Transcription:

HPFM GEN3 - High Pressure Flow Meter Principle of Measurement Specifications System overview Features & Benefits Operation Procedure Calibration Applications

HPFM - Hydraulic Conductance The HPFM is an instrument designed to perfuse water into an object while slowly changing the delivery of pressure and simultaneously measuring flow.

HCFM - XP The HCFM is an Extra Portable version of our HPFM system, which is designed for Hydraulic Conductance tests that requires constant traveling.

The HPFM can acquire data on the Flow of clean water as well as Pressure at which the water was delivered. The gradient or slope of the flow plotted versus pressure equals the hydraulic conductance of the object Measurements: Transient Regression Quasi-steady state conductance HPFM - Theory

HPFM - How It works Inlet side connects to the 8- way manifold and a pressure transducer (PT1). Outlet side another Transducer (PT2) is connected to a second manifold Water flow across the CT causes a differential pressure drop (dp). Calibration curves for the CT relate the Flow to dp in the range of 0 100 kpa

Major Components include: Captive Air Tank Water Filter (2) Manifolds (2) Pressure Transducers (8) unique pieces of tubing of known length and inner diameter Data Acquisition Electronics PC & Software HPFM - System Overview

HPFM - Features New High Res Generation 3 HPFM Reading Sensors direct in parts per million NIST calibration standard feature Instant data regression, and auto-saver aged results USB powered data acquisition New High speed sensor conversion module Flow ranges increased by 50% Vista, XP, supported Windows 7 compatible Upgrade packages available to previous version HPFM systems, with new factory calibration

HCFM-XP - Features HPFM Compatible Portable Suitcase version Stem Ranges - 1 mm to 36 mm Flow Rates 0.01 to 100 grams/hr in 5 ranges Conductance 7.7E-08 to 6.5E-04 Kg s-1 MPa-1 Upgraded Windows Software Data Interface - Parallel Cable to printer port Faster bleeding results time saving between refills Easier setup suitable for short-stop field testing Traveling portable, no more packing and shipping Light Overall Weight 37 lb. (16.8 Kg)

HPFM - Accessories Water Refill Kit Coupling Set Pressure Supply Kit

HCFM - Accessories

Benefits of using the HPFM Quantitative root and stem analysis - 10 minutes. No need to dig up root systems, wash them or try to estimate the area of the root system Can help build the total conductance of a plant/soil/atmosphere relationship Software accurately and intelligently measures conductance

HPFM - Field Operation

Stem Preparation & Coupling Installation Excise the root or stem with a clean perpendicular cut Prep the stem by removing bark Do not restrict the flow with the rubber grommet Lubricate the Coupling Thread with G4 compound. Remove any air from the internal areas of the coupling using a hypodermic needle.

HPFM - Measurement Considerations Wounding Response of the Plant Osmotic (mineral) plugging Response in Root Systems Microscopic Air Bubbles Compression of the cross section face of the root or stem by the compression coupling Leaks in fluid carrying lines and fittings Temperature Compensation of Readings

Acceptable Air Bubbles Microscopic air bubbles compressed initially as pressure increased Then flow/pressure flattens out to record a linear response

Unacceptable Air Bubbles Large air bubbles compressed initially as pressure increased (flow goes up and then down) Then rapidly drop off as pressure continues to increase forming a non linear response. There are not very many good data points

Transient Regression Transient regression This is a transient because the pressure increased as the flow was recorded. The user picks the begin (1) and end (2) points, then Perform Regress (3). A steady state mode is also available. 1 2 3

Quasi-Steady State Flow Meter Constant flow with constant applied pressure

New Graphic Features Interactive Graphics Zoom Un-zoom Print View Real-time Data

Factory Calibration Ensure Most Accurate Data Collection

Project Manager Manage Project Made Easy Create new projects Add project notes Search previous projects by date

Applications Root conductance in the lab or field. Conductance of shoots and petioles with or without leaves. Root Stress Analysis on trees or crops. Modeling root to shoot communications. Transpiration models. Root water status studies. Absolute varietal comparison statistics. Micorrhyzae nutrient/water enhancement studies. Soil to root conductance statistics. Crop conductance studies.