Technical Committee on LP-Gas at Utility Gas Plants

Similar documents
The Application of Temperature and/or Pressure Correction Factors in Gas Measurement

IRC 2011 All Rights Reserved

ACFM vs. SCFM vs. ICFM Series of Technical White Papers from Squire-Cogswell

The most common terms rating air flow capacity are ICFM, FAD, ANR, SCFM or nl/min

Device Description. Operating Information. CP Q (eq. 1) GT. Technical Bulletin TB-0607-CFP Hawkeye Industries Critical Flow Prover

Advanced Management of Compressed Air Systems Pre-Workshop Assignment

Modeling a Pressure Safety Valve

SIZING AND CAPACITIES OF GAS PIPING

CHAPTER 3 : AIR COMPRESSOR

Application Worksheet

Single & Headered Relief Vent Piping Analysis

SIZING AND CAPACITIES OF GAS PIPING Reserved

Full Internal Relief Valves Instruction Manual

The Hoffman Specialty Series 2000 consists of main

Natural Gas Gathering

SIZING AND CAPACITIES OF GAS PIPING

Fundamentals of Compressed Air Systems. Pre-Workshop Assignment

Comments on Homework. Class 4 - Pressure. Atmospheric Pressure. Gauge vs. Absolute Pressure. 2. Gauge vs. Absolute Pressure. 1.

SIZING AND CAPACITIES OF GAS PIPING

Applied Fluid Mechanics

OVERVIEW. Flow Coefficient C v. Operating Conditions. Specific Gravity

Chapter 13 Gases, Vapors, Liquids, and Solids

KNOWN: Mass, pressure, temperature, and specific volume of water vapor.

****** * EX * ****** DWN W.W.POWELL CALCULATION OF FLOW LOSSES IN INLET CHK D.PAPA AND DISCHARGE HEADERS ASSOCIATED WITH

Pressure Control. where: p is the pressure F is the normal component of the force A is the area

Comments on Homework. Quiz. Class 3 - Pressure. Atmospheric Pressure. 2. Gauge vs. Absolute Pressure. 1. Definitions. Temperature conversion

44 (0) E:

SAMPLE RH = P 1. where. P 1 = the partial pressure of the water vapor at the dew point temperature of the mixture of dry air and water vapor

Equipment, Design, and Installation of Closed-Circuit Ammonia Mechanical Refrigerating Systems

DESIGN DATA. Dry 105a. September 5, 2008

Reservoir Fluid Fundamentals COPYRIGHT. Dry Gas Fluid Basic Workflow Exercise Review

COMMITTEE DRAFT. API 520 Part I 10 th Edition Ballot Item 2.1. This ballot covers the following item:

ANDERSON GREENWOOD. Provides reliable overpressure protection in a cost effective package. Flow Control

Engineering Information. Flow Data. Flow Data. Importance of Valve Sizing. Estimating Cv or Orifice Size:

Venting Atmospheric and Low-pressure Storage Tanks API STANDARD 2000 SEVENTH EDITION, MARCH 2014

SG TF. Q = 963 Cv (P1 - P2)(P1 + P2) TECHNICAL INFORMATION. Flow Q (GPM)

PROPERTIES OF R-134A (1,1,1,2-TETRAFLUOROETHANE)

Quick Reference Technical Data

DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITIES

S.A. Klein and G.F. Nellis Cambridge University Press, 2011

MSC Guidelines for Pressure Vessels

RELIEF CAPACITY CURVES

ASHRAE made significant changes in 2001 to the calculations. Fundamentals of Safety Relief Systems

Gas Turbine Performance Analysis

The Discussion of this exercise covers the following points: Pumps Basic operation of a liquid pump Types of liquid pumps The centrifugal pump.

LECTURE 20 FLOW CONTROL VAVLES SELF EVALUATION QUESTIONS AND ANSWERS

Type R622 Pressure Reducing Regulator

Gerald D. Anderson. Education Technical Specialist

API Standard Venting Atmospheric and Low-Pressure Storage Tanks: Nonrefrigerated and Refrigerated

1 PIPESYS Application

Noth American 7347 High Pressure Gas Regulators

ENGR 292 Fluids and Thermodynamics

Methods of Rating Flow

pumping gases JET PUMP TECHNICAL DATA

Control Valve Sizing. Sizing & Selection 3 P 1. P 2 (Outlet Pressure) P V P VC. CONTENTS Introduction Nomenclature Calculating C v

Venting Atmospheric and Low-pressure Storage Tanks API STANDARD 2000 SEVENTH EDITION, MARCH 2014

Permeability. Darcy's Law

2 are both ways of saying a ratio of 2 to 5

Technical data. Back pressure limit: 27.5% of set pressure. Capacity certification: ASME Boiler & Pressure Vessel Code Section I and VIII

T208VR Series Tank Blanketing Vacuum Regulator

Figure Vapor-liquid equilibrium for a binary mixture. The dashed lines show the equilibrium compositions.

The capacity of the cargo tank venting system (46 CFR );

The Use of a Process Simulator to Model Aeration Control Valve Position and System Pressure

Unit C-2: List of Subjects

ARI-SAFE-SN ANSI Safety valve ANSI - safety valve Semi Nozzle (ANSI )

Detailed Thermal Inbreathing Analysis for API 12-F Tanks

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

Gas viscosity ( ) Carr-Kobayashi-Burrows Correlation Method Lee-Gonzalez-Eakin Method. Carr-Kobayashi-Burrows Correlation Method

CONTROL VALVE SEAT LEAKAGE

TUTORIAL. NPSHA for those who hate that stuffy word. by Jacques Chaurette p. eng. copyright 2006

ES&H Manual Pressure and Vacuum Systems Safety Supplement

Practical Guide. By Steven T. Taylor, P.E., Member ASHRAE

This portion of the piping tutorial covers control valve sizing, control valves, and the use of nodes.

Pressure Relief Valves

FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS

plumbing SAFETY AND RELIEF VALVES PART II

RELIEF VALVES & RELEASES

Exercise 4-2. Centrifugal Pumps EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Pumps

FDE 211 Material & Energy Balances. Instructor: Dr. Ilgin Paker Yikici Fall 2015

SIZING AND CAPACITIES OF GAS PIPING

Pressure on Demand. Air Pressure Amplifiers

PURE SUBSTANCE. Nitrogen and gaseous air are pure substances.

CALCULATING THE SPEED OF SOUND IN NATURAL GAS USING AGA REPORT NO Walnut Lake Rd th Street Houston TX Garner, IA 50438

Example: Calculate the density of methane at 50 psig and 32 ⁰F. H.W. In previous example calculate the density of methane in gm/m 3.

Limited quantities of compressed gases.

Pump-Fan-Compressor Sizing

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C

To convert to millimeters of mercury, we derive a unit factor related to the equivalent relationship 29.9 in. Hg = 760 mm Hg.

APPLICANT CHECKLIST FOR NEW REFRIGERANT APPLICATION SUBMISSION TO ASHRAE SSPC 34 DESIGNATION AND NOMENCLATURE INFORMATION.

Example: 25 C = ( ) K = 298 K. Pressure Symbol: p Units: force per area 1Pa (Pascal) = 1 N/m 2

3 1 PRESSURE. This is illustrated in Fig. 3 3.

CHAPTER 16 %UHDWKLQJ*DV0L[LQJ3URFHGXUHV

PENBERTHY SERIES LM, ELL, FL, GL, GH, U, L AND 2NC FOR PUMPING GASES

Case 12 Multistage Centrifugal Refrigeration System Halocarbon Refrigerant

Tutorial. BOSfluids. Relief valve

PETROLEUM ENGINEERING 310 FIRST EXAM. September 22, 2000

A centrifugal pump consists of an impeller attached to and rotating with the shaft and a casing that encloses the impeller.

then the work done is, if the force and the displacement are in opposite directions, then the work done is.

1. A pure substance has a specific volume of 0.08 L/mol at a pressure of 3 atm and 298 K. The substance is most likely:

Sizing Pulsation Dampeners Is Critical to Effectiveness

Transcription:

Technical Committee on LP-Gas at Utility Gas Plants Addendum to the Agenda Sheraton Denver Downtown 1550 Court Place Denver, CO 80202 August 7-8, 2013 The following items relate to item 5.B of the Agenda: Attachment A: Suggested change to pressure relief valve sizing Attachment B: Suggested change in legislative text Attachment C: Recommended substantiation for revision

Attachment A: Suggested Change to Pressure Relief Valve Sizing

10.2.3 For ASME containers holding propane, with a maximum pressure of 300 psi or less, the minimum rate of discharge of installed pressure relief valves shall be in accordance with Table 10.2.3 or shall be calculated using the following formula: F 53.632 A 0.82 F = flow rate (SCFM air) A = total outside surface area of container (ft 2 ) 10.2.4 For ASME containers not covered by 10.2.3, the minimum rate of discharge of installed pressure relief valves shall be sufficient to relieve vapor produced by vaporization that occurs when a heat input of Q=34,500A 0.82 is applied to the vessel, Q = heat input (Btu/hr) A = total outside surface area of container (ft 2 )

Table 10.2.3 Pressure Relief Valve Flow Capacity as a Function of Container Surface Area Surface Area (ft 2 ) Flow Rate (SCFM) Surface Area (ft 2 ) Flow Rate (SCFM) Surface Area (ft 2 ) Flow Rate (SCFM) 20 626 170 3620 600 10,170 25 751 175 3700 650 10,860 30 872 180 3790 700 11,550 35 990 185 3880 750 12,220 40 1100 190 3960 800 12,880 45 1220 195 4050 850 13,540 50 1330 200 4130 900 14,190 55 1430 210 4300 950 14,830 60 1540 4470 1000 15,470 65 1640 230 4630 1050 16,100 70 1750 240 4800 1100 16,720 75 1850 250 4960 1150 17,350 80 1950 260 5130 1200 17,960 85 2050 270 5290 1250 18,570 90 2150 280 5450 1300 19,180 95 2240 290 5610 1350 19,780 100 2340 300 5760 1400 20,380 105 2440 310 5920 1450 20,980 110 2530 320 6080 1500 21,570 115 2630 330 6230 1550 22,160 120 2720 340 6390 1600 22,740 125 2810 350 6540 1650 23,320 130 2900 360 6690 1700 23,900 135 2990 370 6840 1750 24,470 140 3080 380 7000 1800 25,050 145 3170 390 7150 1850 25,620 150 3260 400 7300 1900 26,180 155 3350 450 8040 1950 26,750 160 3440 500 8760 2000 27,310 165 3530 550 9470 This table is applicable to containers holding propane with a maximum pressure of 300 psi or less. For SI units, 1 SCFM = 0.0283 m3/min. Note: Flow rate in SCFM air.

Annex D Relief Device Sizing This annex is not a part of the requirements of this NFPAdocument but is included for informational purposes only. D.1 Nonrefrigerated Containers. D.1.1 Containers Holding Propane, with a Maximum Pressure of 300 psi or Less.Table D.1.1 should be used to size pressure relief valves. Surface area equals the total outside surface area of the container in square feet. Where the surface area is not stamped on the nameplate or where the marking is not legible, the area can be calculated by using one of the following formulas: (1) Cylindrical container with hemispherical heads: Area = Overall length outside diameter 3.1416 (2) Cylindrical container with other than hemispherical heads: Area = (Overall length + 0.3 outside diameter) outside diameter 3.1416 (3) Spherical container: Area = Outside diameter squared 3.1416 Flow rate of air (ft3/min) = required flow capacity in cubic feet per minute of air at standard conditions, 60 F (15.6 C), and atmospheric pressure [14.7 psia (101 kpa)]. The rate of discharge can be interpolated for intermediate values of surface area. For containers with a total outside surface area that is greater than 2000 ft2 (186 m2), the required flow rate can be calculated using the following formula: Flow rate of air ft3 /min 53.632A 0.82 where A = total outside surface area of the container (ft2) (0.4719 L/s) D.1.2 All Other Nonrefrigerated Containers. Pressure relief valves should be sized by calculating the heat input to the container due to fire exposure, calculating the resulting rate of vaporization, and converting the rate of vaporization to a flow rate of air. Heat input can be calculated using the following formula: Q = 34,500A 0.82 Q = heat input (Btu/hr) A = total outside surface area of the container (ft^2) The rate of vaporization can be calculated using the following formula: W vap = Q / L W vap = rate of vaporization (lb/hr) Q = heat input (Btu/hr) L = latent heat of vaporization of the fluid (Btu/lb) The minimum rate of discharge of the pressure relief valves can be calculated using the following formula: F = relieving capacity in SCFM of air and: k a = 1.4, ratio of specific heats of air M a = 28.97 lb/lbmol, molecular weight of air T a = 520 R, absolute temperature of air at standard conditions and the following quantities are evaluated at relieving conditions: W vap = relieving capacity in lb/hr of product vapor k v = ratio of specific heats of product vapor M v = molecular weight of product vapor T v = absolute temperature of product vapor Z v = compressibility factor of product vapor

Table D.1.1 Minimum Required Rate of Discharge in Cubic Feet per Minute of Air at 120 Percent of the Maximum Permitted Start-to-Discharge Pressure for Safety Relief Devices to Be Used on Nonrefrigerated Containers Other than Those Constructed in Accordance with U.S. Department of Transportation Specifications Surface Area (ft 2 ) Flow Rate (SCFM) Surface Area (ft 2 ) Flow Rate (SCFM) Surface Area (ft 2 ) Flow Rate (SCFM) 20 626 170 3620 600 10,170 25 751 175 3700 650 10,860 30 872 180 3790 700 11,550 35 990 185 3880 750 12,220 40 1100 190 3960 800 12,880 45 1220 195 4050 850 13,540 50 1330 200 4130 900 14,190 55 1430 210 4300 950 14,830 60 1540 4470 1000 15,470 65 1640 230 4630 1050 16,100 70 1750 240 4800 1100 16,720 75 1850 250 4960 1150 17,350 80 1950 260 5130 1200 17,960 85 2050 270 5290 1250 18,570 90 2150 280 5450 1300 19,180 95 2240 290 5610 1350 19,780 100 2340 300 5760 1400 20,380 105 2440 310 5920 1450 20,980 110 2530 320 6080 1500 21,570 115 2630 330 6230 1550 22,160 120 2720 340 6390 1600 22,740 125 2810 350 6540 1650 23,320 130 2900 360 6690 1700 23,900 135 2990 370 6840 1750 24,470 140 3080 380 7000 1800 25,050 145 3170 390 7150 1850 25,620 150 3260 400 7300 1900 26,180 155 3350 450 8040 1950 26,750 160 3440 500 8760 2000 27,310 165 3530 550 9470 This table is applicable to containers holding propane with a maximum pressure of 300 psi or less. Note: ft2 = 0.09 m2; ft3/min = 0.4719 L/s.

Attachment B: Suggested Change in Legislative Text

10.2.3 For ASME containers holding propane, with a maximum pressure of 300 psi or less, The the minimum rate of discharge of installed pressure relief valves installed in ASME containers shall be in accordance with Table 10.2.3 or shall be calculated using the following formula: F 53.632 A 0.82 F = flow rate (SCFM air) A = total outside surface area of container (ft 2 ) 10.2.4 For ASME containers not covered by 10.2.3, the minimum rate of discharge of installed pressure relief valves shall be sufficient to relieve vapor produced by vaporization that occurs when a heat input of Q=34,500A 0.82 is applied to the vessel, Q = heat input (Btu/hr) A = total outside surface area of container (ft 2 ) Formatted: Font: Not Bold Formatted: Font: Not Bold Formatted: Superscript Formatted: Font: Italic Formatted: Font: Italic

Table 10.2.3 Pressure Relief Valve Flow Capacity as a Function of Container Surface Area Surface Area (ft 2 ) Flow Rate (SCFM) Surface Area (ft 2 ) Flow Rate (SCFM) Surface Area (ft 2 ) Flow Rate (SCFM) 20 626 170 3620 600 10,170 25 751 175 3700 650 10,860 30 872 180 3790 700 11,550 35 990 185 3880 750 12,220 40 1100 190 3960 800 12,880 45 1220 195 4050 850 13,540 50 1330 200 4130 900 14,190 55 1430 210 4300 950 14,830 60 1540 4470 1000 15,470 65 1640 230 4630 1050 16,100 70 1750 240 4800 1100 16,720 75 1850 250 4960 1150 17,350 80 1950 260 5130 1200 17,960 85 2050 270 5290 1250 18,570 90 2150 280 5450 1300 19,180 95 2240 290 5610 1350 19,780 100 2340 300 5760 1400 20,380 105 2440 310 5920 1450 20,980 110 2530 320 6080 1500 21,570 115 2630 330 6230 1550 22,160 120 2720 340 6390 1600 22,740 125 2810 350 6540 1650 23,320 130 2900 360 6690 1700 23,900 135 2990 370 6840 1750 24,470 140 3080 380 7000 1800 25,050 145 3170 390 7150 1850 25,620 150 3260 400 7300 1900 26,180 155 3350 450 8040 1950 26,750 160 3440 500 8760 2000 27,310 165 3530 550 9470 This table is applicable to containers holding propane with a maximum pressure of 300 psi or less. For SI units, 1 SCFM = 0.0283 m3/min. Note: Flow rate in SCFM air.

Annex D Relief Device Sizing This annex is not a part of the requirements of this NFPAdocument but is included for informational purposes only. D.1 Nonrefrigerated Containers. D.1.1 Containers Holding Propane, with a Maximum Pressure of 300 psi or Less. Table D.1.1 should be used to size pressure relief valves. Surface area equals the total outside surface area of the container in square feet. Where the surface area is not stamped on the nameplate or where the marking is not legible, the area can be calculated by using one of the following formulas: (1) Cylindrical container with hemispherical heads: Area = Overall length outside diameter 3.1416 (2) Cylindrical container with other than hemispherical heads: Area = (Overall length + 0.3 outside diameter) outside diameter 3.1416 (3) Spherical container: Area = Outside diameter squared 3.1416 Flow rate of air (ft3/min) = required flow capacity in cubic feet per minute of air at standard conditions, 60 F (15.6 C), and atmospheric pressure [14.7 psia (101 kpa)]. The rate of discharge can be interpolated for intermediate values of surface area. For containers with a total outside surface area that is greater than 2000 ft2 (186 m2), the required flow rate can be calculated using the following formula: Flow rate of air ft3 /min 53.632A 0.82 where A = total outside surface area of the container (ft2) (0.4719 L/s) D.1.2 All Other Nonrefrigerated Containers. Pressure relief valves should be sized by calculating the heat input to the container due to fire exposure, calculating the resulting rate of vaporization, and converting the rate of vaporization to a flow rate of air. Heat input can be calculated using the following formula: Q = 34,500A 0.82 Q = heat input (Btu/hr) A = total outside surface area of the container (ft^2) The rate of vaporization can be calculated using the following formula: W vap = Q / L W vap = rate of vaporization (lb/hr) Q = heat input (Btu/hr) L = latent heat of vaporization of the fluid (Btu/lb) The minimum rate of discharge of the pressure relief valves can be calculated using the following formula: Formatted: Indent: First line: 0" Formatted: Centered, Indent: First line: 0" Formatted: Superscript Formatted: Indent: First line: 0" Formatted: Centered, Indent: First line: 0" Formatted: Indent: First line: 0" Formatted: Centered, Indent: First line: 0" F = relieving capacity in SCFM of air and: k a = 1.4, ratio of specific heats of air M a = 28.97 lb/lbmol, molecular weight of air T a = 520 R, absolute temperature of air at standard conditions and the following quantities are evaluated at relieving conditions: W vap = relieving capacity in lb/hr of product vapor k v = ratio of specific heats of product vapor M v = molecular weight of product vapor T v = absolute temperature of product vapor Z v = compressibility factor of product vapor Formatted: Indent: First line: 0" Formatted: Indent: First line: 0" Formatted: Indent: First line: 0"

Table D.1.1 Minimum Required Rate of Discharge in Cubic Feet per Minute of Air at 120 Percent of the Maximum Permitted Start-to-Discharge Pressure for Safety Relief Devices to Be Used on Nonrefrigerated Containers Other than Those Constructed in Accordance with U.S. Department of Transportation Specifications Surface Area (ft 2 ) Flow Rate (SCFM) Surface Area (ft 2 ) Flow Rate (SCFM) Surface Area (ft 2 ) Flow Rate (SCFM) 20 626 170 3620 600 10,170 25 751 175 3700 650 10,860 30 872 180 3790 700 11,550 35 990 185 3880 750 12,220 40 1100 190 3960 800 12,880 45 1220 195 4050 850 13,540 50 1330 200 4130 900 14,190 55 1430 210 4300 950 14,830 60 1540 4470 1000 15,470 65 1640 230 4630 1050 16,100 70 1750 240 4800 1100 16,720 75 1850 250 4960 1150 17,350 80 1950 260 5130 1200 17,960 85 2050 270 5290 1250 18,570 90 2150 280 5450 1300 19,180 95 2240 290 5610 1350 19,780 100 2340 300 5760 1400 20,380 105 2440 310 5920 1450 20,980 110 2530 320 6080 1500 21,570 115 2630 330 6230 1550 22,160 120 2720 340 6390 1600 22,740 125 2810 350 6540 1650 23,320 130 2900 360 6690 1700 23,900 135 2990 370 6840 1750 24,470 140 3080 380 7000 1800 25,050 145 3170 390 7150 1850 25,620 150 3260 400 7300 1900 26,180 155 3350 450 8040 1950 26,750 160 3440 500 8760 2000 27,310 165 3530 550 9470 This table is applicable to containers holding propane with a maximum pressure of 300 psi or less. Note: ft2 = 0.09 m2; ft3/min = 0.4719 L/s.

Attachment C: Recommended Substantiation for Revision

Substantiation: This proposed change to NFPA 59 aims to correct a deficiency in the sizing method for nonrefrigerated container relief devices. Jim Stannard raised the concern in Committee Inputs 57, 58, and 59 that the current relief valve sizing method, which was added in the 1953 edition, uses a fixed value for the latent heat of vaporization of the product. The committee statement associated with CIs 57, 58, and 59 says, The 1953 caclulation, which is still in effect in the most recent editions of both NFPA 58 and NFPA 59 is based upon a total heat input Q: Q=34,500A 0.82 Btu/hr. The heat flux value of 34,500 Btu/ft 2 -hr is also adopted in several NFPA codes and standards with some modification for larger vessels. The calculations that led to the adoption of CFM air=53.632a 0.82 in the 1953 edition were apparently based upon a single value for the latent heat of vaporization ( h) regardless of either pressure or composition. (i.e. butane or propane) The latent heat of vaporization used in the equation from the 1953 edition was L=110 Btu/lb, which is the latent heat of vaporization for saturated propane at 300 psig. Using this same value for lower relieving pressures is conservative, because the latent heat of vaporization increases with decreasing pressure, which in turn lowers the relieving flow rate needed. However, if the relief valve has a relieving pressure greater than 300 psig, using the same value for L would result in undersized relief valves. Similarly, the latent heat of vaporization of butane is always less than that of propane at the same conditions, so using the same value of L=110 Btu/lb would result in undersized relief valves. The proposed change to section 10.2.3 addresses this issue by limiting the applicability of the equation F=53.632 A 0.82 to propane only, with a maximum pressure of 300 psig. Most applications will fall under this section, and the same equation and Table 10.2.3 may continue to be used. In other cases, the new section 10.2.4 must be used. This section requires that the rate of discharge of the relief valve be enough to handle the same heat input of Q=34,500A 0.82 Btu/hr, but doesn t proscribe a formula or specific values for the amount of vapor produced or the equivalent air flow rate. The intention is that the system designer will have to perform their own calculations to justify that the relief valve can handle the same heat input on the tank. A suggested, nonbinding method to calculate relief valve size is added to the annex in section D.1.2. This method follows the same method used in the derivation of the 1953 equation, but stops short of substituting in the material properties of the product. Derivation of D.1.2: ASME BPVC Section VIII Division 1 Appendix 11, Capacity Conversions for Safety Valves, provides the following equation for relief valve capacity.

Here, W is the capacity in pounds per hour, K is the coefficient of discharge, A is the discharge area of the safety valve, in square inches, P is the absolute relieving pressure, M is the molecular weight of the gas or vapor, Z is the compressibility factor, and T is the absolute temperature at the safety valve inlet. C is in turn defined by the following equation in terms of k, the ratio of specific heats. We apply this in turn to the product vapor, designated with the subscript v, and test air, designated with the subscript a. We will assume that the compressibility of air is 1, so it will drop out. Note that K and A are properties of the safety valve, so they will not change. The inlet pressure will be the same when relieving product as when testing the valve on air, so P will be constant as well. We can also substitute in the formula for C. Dividing these equations, and cancelling like terms, we get the following. Finally, we relate the mass flow rate of air to the standard volume flow rate of air using its standard density. Here, F is in SCFM and W a is in lb/hr. Substituting and rearranging yields the final equation.