SPECIFICATION // DATA SHEET WATER DRAIN VALVE AM SENSORS LTD AMS-S-084/DS/ (ISSUE 1)

Similar documents
INSTALLATION, OPERATING & MAINTENANCE MANUAL WATER DRAIN VALVE

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

SCA Series Inverted Bucket Steam Traps

MLS Series Liquid Level Switches. Installation and Operations Manual Section 15

Wastewater combination air valve in stainless steel AISI 316 Mod. SCS

Torque Tube TB300 Digital Transmitters

Model NDA Differential pressure transmitter. Deltapi N Series A complete range of pneumatic pressure transmitters

9408 Series Dissolved Oxygen Systems. Dissolved oxygen systems designed for reliable operation with minimal operating costs

Pressure Reducing Valves Pressure Reducing with. Broady Flow Control. D Series Range. Pressure Reducing Valves. Broady Flow Control

Liquid level regulating valves Types PMFL / PMFH and SV

ABB MEASUREMENT & ANALYTICS DATA SHEET series Dissolved oxygen systems

Endura AZ40 Sensor assembly High temperature filter assembly kit

776 Cryogenic Safety Valve

VALFONTA INSTRUCTIONS: OPERATION AND INSTALLATION PRESSURE REDUCING VALVE MODEL PRV44

AE50S Automatic Air and Gas Vent for Liquid Systems Installation and Maintenance Instructions

SV5 Safety Valve Installation and Maintenance Instructions


HM and HM34 Inverted Bucket Steam Traps Installation and Maintenance Instructions

Pressure Reducing Valves Pressure Reducing with. Broady Flow Control. C Series Range. Pressure Reducing Valves. Broady Flow Control

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

CA44, CA44S, CA46 and CA46S Air and Gas Traps

Air Eliminators and Combination Air Eliminators Strainers

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

Modulating liquid level regulators, servo-controlled PMFL / PMFH and SV

Modulating liquid level regulators, direct-controlled, type SV 1 and 3 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

CA10S, CA14 and CA14S Air and Gas Traps

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES. ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified

Serie ECO 3F. Flanged back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection

ABB MEASUREMENT & ANALYTICS DATA SHEET. AP100 ph/redox (ORP) cartridge sensors with water-wash option

ATS430 turbidity sensor Retractable insertion assembly

Float valves Types SV 1 and SV 3

AE14 Automatic Air Vents for Liquid Systems Installation and Maintenance Instructions

Contents. 1. General information BROEN BALLOMAX Steel Ball Valves Approvals Quality Management...2

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

Solenoid valves, two-step on/off Type PMLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Norval Pressure regulator

CA44 and CA44S Carbon Steel Air and Gas Traps Flanged DN15 to DN25

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

CAST IRON SAFETY VALVE TYPE 6301

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

Endura AZ40 Sensor assembly Smart electronics PCB

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

6000 SERIES OF PNEUMATIC DEADWEIGHT TESTERS

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

Regulating valves Type REG 6-65 Type REG-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X

Water. VAG DUOJET Automatic Air Valve Single-chamber type PN 10/16/25/40 - DN KAT-A 1912

GW C300 FLUID CONTROL VALVE PRESSURE REDUCING

Pressure Regulating Valves. Models 44, 77 & 68 PS\ UL. Pressure Relief Valve. Dorot Fire Protection Division. Certification & compliance by design

Horizontal Bladder Tanks

Float valves Types SV 4, SV 5 and SV 6

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

CLASS TLP Pressure Reducing Valve

Vertical Bladder Tanks

756 Safety Relief Valves

Model MTB-ASME Vertical Bladder Tanks

TECHNICAL DATA. Q = C v P S

Pressure regulating valves Types OFV, OFV-SS

Model MTB-ASME Horizontal Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks

AVS32 Stainless Steel Air Vent for Steam Systems Installation and Maintenance Instructions

Company Profile.. About Sammi Machinery

3-PIECE BALL VALVE, 3600 PSI/ PN 248, WITH ISO DIRECT MOUNTING PAD 306M SERIES/ PED Category II

Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series

DN 65 to 100 R.F. PN10 flanges + 5 C + 65 C Max Pressure : 10 Bars Specifications : Brass check valve Controlable With valves DN1/2

AIR FOAM CHAMBER DATA SHEET

Overflow valves Type OFV Type OFV-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS

CA14 SG Iron Air and Gas Trap ½" and ¾" (Screwed)

TECHNICAL DATA. Q = C v P S

Cash Valve. Type G-4. Pilot Operated Pressure Reducing Regulator for Steam, Air and Gases. Flow Control

UIB30 and UIB30H Sealed Inverted Bucket Steam Traps for use with Pipeline Connectors

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L

FOAM TANK (1/2) DATA SHEET

Materials : Carbon steel ASTM A216 WCB

TECHNICAL DATA. Q = C v P S

Gas Pressure Regulator HON 200

BACK PRESSURE / SUSTAINING

RR 16 Commercial & Industrial Regulator

TECHNICAL DATA CAUTION

Performance Literature for J48. Gas Pressure Regulators 2½ 6 Sizes. Catalogue

North American Simplex Basket Strainers for Gas and Oil

Eaton Filtration, LLC

VESSEL & REACTOR VALVES. VS Series SPRAY & RINSE VALVES PROCESS VALVES

CA46S Austenitic Stainless Steel Air and Gas Trap DN40 and DN50

Serie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E

TECHNICAL DATA. Q= Cv S

SAN ANTONIO WATER SYSTEM I.H. 10 Ground Storage Tank Rehabilitation and Painting Project SAWS Job No Solicitation No.

Safety Blocks Brochure

TSS21 Sealed Thermostatic Steam Tracer Trap

Gas Pressure Regulator HON 502

Tank Blanketing Pressure Regulators RHPS Series

SR100 Series Service Regulators. Technical Bulletin

Safety relief valves Type SFA 15 and SFA 15-50

Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections

Transcription:

SPECIFICATION // DATA SHEET WATER DRAIN VALVE 1

Introduction The Water Drain Valve was developed for a major oil company to detect the presence of fuel when discharging water through the drain line of a fuel storage tank. Its float operation ensures that when you drain water built up in a tank (caused by rain or condensation) the density change from water to fuel is detected causing the valve to close, saving valuable medium from being wasted and preventing any damage to the environment through contaminated water discharge. Mechanical in operation with only one moving part the Water Drain Valve design enables easy installation with low maintenance costs. The hydraulic design is such that it is unaffected by flow but very rapid in response to density change. The float profile ensures that when the density change occurs, a liquid tight seal is created against the valve seat. Both the cast and fabricated versions of the valve are supplied with a manual test facility to enable regular checking of the valves operation. Key Benefits Mechanically operated Easy to install Low maintenance requirements Environmental protection Prevents pollution Reduces wastage of valuable stock Heavy duty for durability Customisable to suit application requirements Manual test facility Rapid response to density change CAST VERSION FABRICATED VERSION 2

Operation If during the draining stage hydrocarbons / fuel enters the float chamber the float will reseat due to the change in fluid S.G. forming liquid tight seal to preventing an uncontrolled release of hydrocarbons / fuel to the environment. INLET FROM TANK Over a period of time water draining into the valve will displace any hydrocarbons / fuel as the level builds up in the base of the storage tank. The next time the tank is drained no hydrocarbons / fuel will be discharged. With the tank isolation valve in the open position, any water / condensation will slowly start to fill the float chamber in the Water Drain Valve, once the water rises in the float chamber and is level with the top of the float, the float will become buoyant and water will pass through the valve seat and fill the second chamber and pipeline up until the discharge control valve. At routine periods set by the user, an operator can slowly open the discharge control valve which will allow any water built up in the valve to be drained, when the flow of water stops the discharge control valve can be closed. FABRICATED VERSION DISCHARGE 3

Installation The Water Drain Valve should be installed in the storage tank drain line, close to the tank outlet. The valve should be situated after a storage tank isolation valve and before a discharge control valve. There is no minimum distance required between the isolation and control valve and the Water Drain Valve inlet and outlet; however AMS would recommend a distance of at least 200mm. TANK ISOLATION VALVE INLET FROM TANK DISCHARGE CONTROL VALVE Note: The WDV s are designed for use in gravity fed system and do not operate on a pump fed system, for density shut off on pump fed systems please refer to the AMS fuel grade monitoring valve. DISCHARGE TO DRAIN SUGGESTED INSTALLATION FOR THE CAST WATER DRAIN VALVE WITH SCREWED CONNECTION (OPTIONAL FLANGED VERSION ALSO AVAILABLE) 4

Specification Cast Versions 2 Fabricated Version 4 Fabricated Version Part No: WDV-SV2050 / WDV-SV2056 WDV-SV2107 WDV-SV596 Body Material: Aluminium Alloy or 316 Stainless Steel 316L Stainless Steel / Carbon Steel 316L Stainless Steel / Carbon Steel Float Material: Polypropylene Polypropylene Polypropylene Seal Materials: Viton / Klingersill Viton / Klingersill Viton / Klingersill Std Process Connections: Screwed connections 2.5 BSPP or 2 NPT Flanged Connections 2 or 3 ANSI/ASME 150lb or 300lb* Flanged 2 ANSI/ASME 150lb. RF Flanged 4 ANSI/ASME 150lb. RF Max Flow Rate: 300 Ltrs/Min 300 Ltrs/Min 1250 Ltrs/Min Max Line Pressure: 10 Bar 10 Bar 15 Bar Temperature Rating: -18 to 200 C -18 to 200 C -18 to 200 C Weight: 10 Kgs 35 Kgs 70 Kgs *Other flange sizes/ratings available on request. Maximum medium specific gravity (S.G) with the standard float is 0.92; the float will close in all mediums with an S.G below this value. When the line medium freezes the valve will return to operation once the medium has thawed. Although Viton seals have a brittle point of -45 C and can operate satisfactorily at temperatures approaching this, it is recommended that they are replaced if subjected to temperatures below -18 C before the valve returns to operation. AMS specialise in custom made instrumentation & valve products and as such offer a wide range of documentation options and where possible, will amend standard features to meet customer specific requirements. A version of this valve can also be used to detect the difference between two fuels to ensure the correct product is being emptied into storage tanks, see our Density Sensitive Valve for more information. 5

Dimensions A B C WDV-SV2107 (2 ) 516mm 280mm 668mm WDV-SV596 (4 ) 810mm 458mm 1089mm 235MM 62MM C A 430MM B CAST VERSION FABRICATED VERSION 6

Ordering Information Part Number Selection Water drain valve WDV- XXXX- XX- X- X- XX Base model 4 Fabricated version SV596 2 Fabricated version SV2017 2 NPT cast version SV2056 2 BSPP cast version SV2050 Body material Aluminium Alloy (Cast) Grade: Lm 25M Stainless Steel (cast) grade: bs3100 316 c16 Stainless Steel (fabricated) grade: 316ss Carbon steel (fabricated) grade: ASTM A106 (Body) / ASTM A234 (Elbows & Reducers) Flange material 316 Stainless steel grade: astm a182 f316 Carbon Steel grade: astm a105 No Flange 0 Flange size 2 2 AC SC SF CF S C Paint Specification The Cast Aluminium and Fabricated Carbon Steel Water Drain Valves are supplied painted with Amercoat 385 Multi-Purpose Epoxy (+120 Deg C Max), AMS Blue Colour (RAL 5005) as standard. AMS can supply the Water Drain Valves painted to suit individual customer paint requirements, please specify at time of enquiry. Spares MSK-SV596 MSK-SV2107 MSK-SV2056 MSK-SV2050 SV399 Maintenance Spares Kit for SV596, includes 1 x gasket for body/cover, 1 x SV384 Plunger Assembly and 1 x SV404 Float Maintenance Spares Kit for SV2107, includes 2 x gasket for body/cover, 1 x SV471 Plunger Assembly and 1 x SV375 Float Maintenance Spares Kit for SV2056, includes 1 x gasket for body/cover, 1 x SV364 Plunger Assembly and 1 x SV375 Float Maintenance Spares Kit for SV2050, includes 1 x gasket for body/cover, 1 x SV364 Plunger Assembly and 1 x SV375 Float Float Guide Assembly (SV596) 3 3 4 4 Others (special) Flange rating 150lb ansi/asme b16.5 300lb ansi/asme b16.5 Others (special) X 15 30 X SV2070 SV273 Float Guide Assembly (SV2107) Float Guide Assembly (SV2050/SV2056) 7

Documentation and Testing AMS can supply the Water Drain Valves with documentation to suit individual customer requirements, these documents include but not limited to: Material Certification EN 10204-3.1 Hydrostatic Pressure Test Certificates Weld Procedures Welder Qualifications Certificate of Conformity PED Installation, Operation and Maintenance Manual etc Non-destructive Testing Material Analysis Special Tagging Inspection and Test Plans In addition to the above AMS can also provide: Accessories: AMS offer a range of accessories for use in conjunction with the Valves, such as Gaskets, nuts/bolts and fittings. Instrumentation: AMS offer a range of process instrumentation and valves to cover a wide variety of process measurement applications. 8

AM Sensors Ltd, Chedzoy Lane, Chedzoy, Bridgwater, Somerset TA7 8QS AMS-S-084/DS/03.2015 (ISSUE 1) t +44 (0)1278 444 650 f +44 (0)1278 434 449 e info@amsensors.com www.amsensors.com AM SENSORS LTD (AMS) RESERVE THE RIGHT TO MAKE TECHNICAL CHANGES OR MODIFY THE CONTENTS OF THIS DOCUMENT WITHOUT PRIOR NOTICE. AMS DOES NOT ACCEPT ANY RESPONSIBILITY WHATSOEVER FOR POTENTIAL ERRORS OR POSSIBLE LACK OF INFORMATION IN THIS DOCUMENT. AMS RESERVE ALL RIGHTS IN THIS DOCUMENT AND IN THE SUBJECT MATTER AND ILLUSTRATIONS CONTAINED THEREIN. ANY REPRODUCTION, DISCLOSURE TO THIRD PARTIES OR UTILIZATION OF ITS CONTENTS - IN WHOLE OR IN PARTS IS FORBIDDEN WITHOUT PRIOR WRITTEN CONSENT OF AMS. 9