CanNeed-DSST-100 Digital Secure Seal Tester --- To evaluate the secure seal quality of PET bottles, glass bottles and cans

Similar documents
Installation, Operation and Maintenance Manual for Back Pressure Regulator

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

Adjustment & Calibration Instructions

Vibration isolation system 1VIS10W. User manual

Valve test benches. Systems overview

Models 461-S, 461-8S and S Regulators. R-1330 Rev. 7

OWNER S TECHNICAL MANUAL

GAS ANALYSER OXYBABY M+ for O 2. or O 2 /CO 2. standard version

Composite Pistol-Type Air Needle Scaler OWNER S MANUAL

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

BS Series Basket Strainer

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

Operating Manual ALU 7 - ALU 10 - ALU 20 - ALU 26 ALU 35 - ALU 60 - ALU 100

Installation Operating Instructions for Duplex Manual Manifolds PX-TMD Series

Hydraulic hand test pump Models CPP700-H and CPP1000-H

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

Aging Cell, OFITE Style. Included Items

Variable Area Flow Meters

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

Air Pressure Relief Valves

Smooth Vent Valve. Series XVD XL XL Q D- XVD XGT CYV

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP

SF SERIES CNG COMPRESSOR MODEL HF-4MH. 4 Nm3/Hour Displacement OPERATION MANUAL

PRO-50 Instrument Supply Regulator

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

CSA Sample Draw Aspirator Adapter Operator s Manual

Benefits. Rev.III_032018_Oxybaby 6.0_engl subject to technical alterations

MEGR-1912 Instruction Manual

VACUUM REGULATORS CONTENTS

Tri-Tech Medical Inc.

INSTRUCTION MANUAL EBA-75 CLOSED-CIRCUIT ESCAPE RESPIRATOR (CCER) CAPACITY 3

CLASS D - SENSITIVE LEAK TEST GAS AND BUBBLE METHOD. 1.1 To provide definitive requirements for PNEUMATIC pressure testing of piping systems.

COSMO INSTRUMENTS CO., LTD.

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

Pneumatic Hand Pumps with no Gauge Connection (scissor handle) AP0V (300 psi / 20 bar)

GUIDELINES FOR CONDUCTING HYDROGENATION REACTIONS

COMPACT TRIPLE WALL OUTLET STATION MODEL INSTALLATION AND OPERATING INSTRUCTIONS

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

Schroeder Check Test Point System

LNG Regulator Test Kit

INTENDED USE TECHNICAL SPECIFICATIONS

ALU-CD 12, ALU-CD 25, ALU-CD 35, ALU-CD

Instruction Manual Updated 7/26/2011 Ver. 2.2

Smooth Vent Valve XVD. Series

PCS 340 Core Saturator : 115 Volt : 230 Volt. Instruction Manual

INSTRUCTION MANUAL. CVS P37 LP Gas Reducing Regulator

AIR DISTRIBUTOR. PART NUMBER (Including, but not inclusive) AD28483-_ALB, AD28563-_ALB, AD36097-_ALB, AD36098-_ALB, AD28485-_ALB

2.0 INSTALLATION & SERVICE

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691

Ultrasonic baths. XUB range of digital ultrasonic baths. XUBA range of analogue ultrasonic baths. Digitally controlled range with a choice of 5 baths

Smooth Vent Valve. XVD Series

Pressure Dump Valve Service Kit for Series 2300 Units

Rejuvenation Instructions

AIR DRIVEN. Gas Boosters & SYSTEMS. Accepting VISA, MasterCard and American Express

krones Sensometic VP and VPL The intelligent probe filler systems

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X

OPERATING INSTRUCTIONS

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

Nitrous Oxide / Oxygen FLOOR MOUNTED OUTLET STATION Installation and Instructions

Float Operated Level Controllers

Instructions for use Compressed air injector with water trap

256 Pneumatic Pressure Indicator

Coiling Tube with Twist-Proof Fitting

Operation Manual. PEGAS NovoTap, PEGAS NovoTap+

TECHNICAL DATA. Q = C v P S

INSTRUCTION MANUAL FOR EBA MINUTE SELF-CONTAINED SELF RESCUER (SCSR) Manual Number: NH13747 Revision: A, ECN 2384 September 7, 2001

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

XpressFill XF2500 Counter Pressure Filler. Operating Instructions

tel: fax: web:

Dri-Line Mk3 Monnier Compressed Air Drain Trap

Differential Pressure Control Valve (DPCV)

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

AUTOMATIC HOSE TEST UNIT, TYPE SPU

MoveRoll Conveyor Operating and Maintenance Manual

OWNER S MANUAL. Page: 1 of 8

Installation, Operation, and Maintenance Manual

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

TECHNICAL DATA. Q= Cv S

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Compatible with a Wide Range of Gases or Liquids for Laboratory or Plant Applications

PRESSURE TEST PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model No: PTP100. Part No: GC01/09

6000 SERIES OF PNEUMATIC DEADWEIGHT TESTERS

CONTROL VALVE TESTING

TEST BENCH SAFETY VALVES ¼ - 5 DN10 DN125

INSTALLATION AND OPERATING INSTRUCTIONS

RK-IR Sample Draw Aspirator Adapter Operator s Manual

1800C and 1800C-HC Service Regulators

IX1 Spirax-Monnier International Compressed Air Filter Installation and Maintenance Instructions

Leak testing of Valves. Standards for acceptable Rates of Valve Leakage

User Information Sheet 013

BERMAD Fire Protection Hydraulic Control Valves

CLASS DH - PNEUMATIC TESTING - GREATER THAN 1 BAR (15 PSIG)

Transcription:

CanNeed-DSST-100 Digital Secure Seal Tester --- To evaluate the secure seal quality of PET bottles, glass bottles and cans New piercing mode Traditional Piercing Mode

The CanNeed -DSST-100 Digital Secure Seal Tester is used to test seal integrity of the glass or plastic containers and cans. The CanNeed-DSST-100 has been designed to address the special needs of sealing cans and bottles that use aluminium roll-on, twist crowns, or plastic caps. The CanNeed -DSST-100 operates with compressed air, nitrogen, or carbon dioxide. By detecting gas leakage, rather than liquid, the Secure Seal Tester gives more sensitive, accurate readings. CanNeed-DSST-100 is constructed from anodized aluminium, stainless steel and plastic materials. The tester's rugged construction withstands production line abuse, yet is accurate enough for laboratory use. Attributes: 1) Digital displays and save the measuring results. 2) RS232 C data output. The data can be automatically output to SPC system. 3) Convenient operation with vacuum piercing head, avoiding any measuring failure because of the poor integrity of the piercing head. 4) Programming lifting pressure. The measuring upper limit and the time to the maximum pressure are adjustable. 5) Before increasing to the max. pressure (SP-2), the pressure hold time of the preset pressure (SP-1) is adjustable. 6) Two speed adjustment valves to adjust the two pressure lifting rates separately. 7) Several safety protection measurements. 8) Adopt imported world-branded control valves, connecting heads and pipes. Our quality can be compared with the same products in the world. 9) High sensitivity and high accuracy. 10) Pressurize with compressed air or CO2. 11) Made from oxidized aluminium, stainless steel and plastic, stable and durable. 12) Measuring pressure range: 0-16 bar (1.6 Mpa). 13) The max. dimension of the measuring samples: 330 150mm (height diameter) Standards of Qualified Sealing Integrity PET bottled beverage without gas, such as mineral water or tea beverage PET bottled beverage with gas, such as Cola Glass bottle-crown cap, such as beer : 0.2 Mpa : 1.0 Mpa : 1.0 Mpa

Glass bottle-plastic cap and Aluminium twit-off cap, such as sauce and spirit Canned food or Canned beverage : 0.2 Mpa : 0.2 Mpa Canneed Instrument (HongKong) Limited Many safety features have been built into the CanNeed-DSST-100 Digital Secure Seal Tester. Some of these safety features are the series safety valve, the aligning hole arrangement in the lid, and the rapid venting characteristic. Others include the secure lid latch, the regulator relief valve and the concept that the test container is submerged in water surrounded by a cylindrically-shaped tank. Application 1: Pressurizing Test: the seal integrity of PET bottle cap The seal integrity of PET bottle cap is very import for the quality of PET bottles. Many manufacturers tend to buy CanNeed -DSST-100 Digital Secure Seal Tester to test the seal integrity of PET bottles, in order to effectively control the seal integrity of the products, avoiding gas leakage. Thus, CanNeed-DSST-100 is widely used in beverage industry. Here are the inspection indicators and inspection methods: 1. Indicators of Qualified Sealing Integrity of PET Bottle Cap 100psi 125psi 150psi 175psi <100psi Unacceptable Leakage (correct) *100psi=0.69Mpa Acceptable (But may indicate trend. Look for cause and correct)* Acceptable (typical value) >175psi Some inspectors may change the above inspection indicators based on their needs. 2. Inspection Methods 1) Fill the water tank to approximately 10cm from top of tank. This level assures the closure will be covered with water. 2) Regarding to PET bottles, cut off the bottle cap together with the bottle mouth at the position of bottle neck. Then, seal it with a special clamp provided. 3) Connect the sample with the measuring head. Put the sample into the water tank, and then close the machine cover. Please check whether the cover is locked well. 4) Regarding to glass bottles and 2-pc cans, pierce a hole on the bottle caps with the special-made piercing device of CanNeed -DSST-100, then run VENT to ensure the seal integrity between of piercing and bottle caps.

5) Put the sample into the water tank, close the machine cover, and then press START. 6) The pressure inside the sample will be increased according to the preset rate until it is up to the first preset upper limit (SP-1). 7) The timer will do the pressure-holding for the pressure inside the samples. When he pressure-holding is over, the pressure will continue to increase to the max. measuring pressure according to the preset rate. 8) If there are bubbles during the test process, press STOP. Meanwhile, the it will display the current max. pressure value. 9) The data can be output via RS port. Pressure pressure limit 2 limit 1 = limit 2 limit 1 Tempo 0 time 0 time 10) When the test is over, decrease the pressure inside the sample to ZERO. Loosen the machine cover and take the samples out of the water tank. 11) Disconnect the gas pipe from the pressurizing fixture, screw out the pressurizing fixture and take the sample out. The frequency of testing filled product with the CanNeed-DSST-100 needs to be developed by each individual bottler. Factors which could affect the frequency of testing are condition of the roll-on capper, line speed, number of different vendors used for closures and containers, and the frequency of preventative maintenance of the capper. 3. Suggested Testing Frequency and Methods 1) Remove three containers from each capper head at the beginning of each shift. Observe all three samples from each head for visual thread definition. Test on sample from each head in the CanNeed-DSST-100 and record the results. If any of the containers fail the CanNeed-DSST-100, test the remaining two containers from specific capper head which failed the CanNeed-DSST-100. If either of the

remaining two containers fails the CanNeed-DSST-100, corrective action should be taken. 2) Containers should be tested after each capper head adjustment. 3) Containers should be checked in the CanNeed -DSST-100 when changing to a new lot of containers or closures, or when switching to a different vendor of either closures or containers. 4) Containers should be checked after any jam-ups in the capper. 5) Routine testing frequency on the CanNeed -DSST-100, when neither 3 or 4 above has occurred, needs to be developed by the individual bottler; however, we recommend a test frequency of every other hour as outlined in #1 above. 6) Note: These values have been established by many users as sufficient to provide assurance of a secure seal with above containers and closures. Individual bottlers may choose to modify the test procedures outlined according to their needs. Examine all defects and retest packages as required to determine the causes for lack of a secure seal. Corrective action should be taken immediately when leakage is observed on the CanNeed -DSST-100. 4. Theory of Operation CanNeed -DSST-100 Digital Secure Seal Tester is a set of equipment used to evaluate the seal of an aluminum roll-on type closure to either glass, plastic containers and cans. The test is preformed by inducing gas, at a controlled rate, into the headspace of a bottle which is submerged in water bath. The internal pressure build-up is meant to exceed normal conditions present in a carbonated beverage container. This excess pressure tests the security of the container finish-to-closure relationships, i.e., thread definition. Containers which are securely sealed will accept the excess pressure and show no signs of gas leakage. Containers which are not securely sealed will be revealed by the emission of small bubbles coming from the closure area. These bubbles can be easily seen by the operator. The ability to observe gas leakage rather than liquid leakage provides for a maximum degree of test sensitivity. The gas pressure which is produced in a test container is controlled by a regulator and flow control valve. The ability to regulate the pressure permits the user to determine the maximum pressure a closure or container can withstand before gas leakage occurs. By controlling to flow rate a more accurate

simulation of container pressure build-up is given. Many safety features have been built into the CanNeed-DSST-100 Digital Secure Seal Tester. Some of these safety features are the series safety valve, the aligning hole arrangement in the lid, and the rapid venting characteristic. Others include the secure lid latch, the regulator relief valve and the concept that the test container is submerged in water surrounded by a cylindrically-shaped tank. However, some cautionary measures should be taken to ensure the complete safety of the user. CanNeed-DSST-100 Digital Secure Seal Tester is a statistical quality control tool and does not guarantee defect-free package leaving the filling lines. It is a useful part of capping quality control system, but it is not a substitute for other elements of such a system, as recommended by the manufacturers and suppliers of cappers, containers and closures. Interpretation of the CanNeed-DSST-100 results is at the discretion of the user.