UNCC Biotechnology and Bioinformatics Camp. Dr. Jennifer Weller Summer 2010

Similar documents
Pipetting Small Volumes

Lab Skills Practice: Pipetting Small Volumes. B3 Summer Science Camp at Olympic High School 2016

Lab 1. Instrumentation Familiarity: Using Micropipetters and Serological Pipettes

Improving Pipetting Techniques

Laboratory #2 Pipetting Technique and Micropipette Calibration Skills=40 pts

SOP-111 Pipetting Small Volumes

For accurate measurements and to prevent damage to the micropipets, follow these important guidelines:

For accurate measurements and to prevent damage to the micropipets, follow these important guidelines:

Adjust the Volume Display

Chapter 2. Pipetting techniques. Guide to Pipetting

Biochemistry Laboratory I CHEM 4401 Pipetting & Scales

Pipettor. User Manual

Operating Instructions. Rainin Classic Manual Pipette

II. MATERIALS REQUIRED FOR PERFORMANCE TESTING

MOLEBIO LAB #1: Microquantity Measurement

Real World Metric System

For accurate measurements and to prevent damage to the micropipets, follow these important guidelines:

Improve pipetting results in pharmaceutical formulation by using MICROMAN E

Inquiry Module 1: Checking the calibration of a micropipette

RayPette Plus Autoclavable Pipette. User Manual

Using a micropipette to transfer exact liquid measurements in scientific experiments By: Nicole Hume

Pipetting and Determining Protein Concentration

The pipettes cover a volume range from 0.1µl to 10ml.

VWR UHP j :01 Page 1. ENGLISH 1 22 DEUTSCH FRANÇAIS ESPAπOL ITALIANO

MULTICHANNEL. Labnet International, Inc.

Standard Operating Procedure. Air Displacement Pipette Calibration

A N F G J I C D D L A B C D E F

Prepared By: Lisa McAvoy 30/Nov/17 dd/mmm/yy. Approved By: Veronica Harris-McAllister 30/Nov/17 dd/mmm/yy

25/04/56. LTC Carmen A. Bell Chief, Laboratory Operations USAMC-AFRIMS

THE UNIVERSITY OF NEWCASTLE - DISCIPLINE OF MEDICAL BIOCHEMISTRY

Transferpette. Testing Instructions (SOP) 1. Introduction. October 1998

Transferpette -8/-12

Transferpette. Testing Instructions (SOP) 1. Introduction. May 2009

CHM250 Calibration and Measurement Lab. Balance Calibration

User s Manual. Autoclavable & UV resistant. Multi-channel digital micro pipette. In Vitro Medical Diagnostic Devices (98/79/EC)

User s Manual. Digital micro pipette for liquid handling CERTIFIED ISO9001

How to Measure R7.1. Reference. I. Linear dimensions

Technical Procedure for General Laboratory Equipment

INTRODUCTION TO THE SPECTROPHOTOMETER AND PIPETTING SKILLS

User s Manual. Autoclavable & UV r e s i s t a n t. Digital micro pipette for liquid handling. In Vitro Medical Diagnostic Devices (98/79/EC)

VOLUMETRIC TECHNIQUES

Fisherbrand. Finnpipette INSTRUCTIONS FOR USE PARK LANE Pittsburgh PA

Experiment 1 Use of Micropipettes: measuring volume accurately

Gel Loading Practice MiniLab

Tips for Proper Pipette handling and Maintenance. D. Muruganand, Ph.D ILQA - Bangalore, Feb 2014

How to Use: 1. Hold the pipette like you are going to shake hands with it.

Calibration of Volumetric Glassware

ali-q TM Gravimetric Verification Procedure

User s Manual. Autoclavable & UV resistant Nichipet EX II. Digital micro pipette for liquid handling. In Vitro Medical Diagnostic Devices (98/79/EC)

BASIC LABORATORY TECHNIQUES (Revised )

MICROMAN ENGLISH. Other languages can be consulted and downloaded on our website,

APPENDIX A CORRECT USE OF DIGITAL PIPETTES

Nichipet EX Plus II. User s Manual. Autoclavable & UV resistant. Digital micro pipette for liquid handling

Lab Equipment ANALYTICAL BALANCE

BASIC LABORATORY TECHNIQUES (Revised )

A N B P F G J I C D D L A B C D E F

PIPETMAN F ENGLISH. Other languages available on our website:

General European OMCL Network (GEON) QUALITY MANAGEMENT DOCUMENT

Eliminating Sources of Pipetting Error in the Forensic Laboratory David M. Epstein Director of Scientific Operations. Abstract.

The use of the analytical balance, and the buret.

Purpose. Introduction

Other languages available on our website:

Determination of Sodium using Atomic Emission

VIAFLO 96. Electronic 96 Channel Hand Held Pipettor

Transferpette. Lightweight precise rugged reliable!

The pipette of Choice for Problem Liquids!

Transferpette. Lightweight precise rugged reliable!

VITLAB micropipette. Standard Operating Procedure (SOP)

A N B P G J I C D L D E

Measuring Mass and Volume

D. De La Matter 2004 Swimming Pool Chemistry STUDENT ACTIVITIES:

Any laboratory is equipped with specific tools, equipment,

Chapter Pipette service & maintenance. Pipette specifications according to ISO Repair in the lab or return for service?

Chemical Industry. School experiments. Weighing. Helper Booklet. Tips and Tricks for Weighing. Natural science laws experience live learn easily

PERFORMANCE TEST INSTRUCTIONS FOR BIOHIT PROLINE PIPETTORS

SoCal BioMed, LLC 4695 MacArthur Court, 11th Floor Newport Beach, CA Phone: +1 (424) Fax: +1 (323)

CHEM 321 Experiment 1

Recording Significant Figures

SoftGrip Single Channel Pipettes User Manual New Photo To Come

VWR HIGH PERFORMANCE PIPETTOR

Transferpette. Single and Multichannel Pipettes

Varipette Operating manual

CH2250: Techniques in Laboratory Chemistry. Outline Measuring Mass Measuring Volume Significant figures. Mass Measurement

Register your instrument! Eppendorf Research plus. User Adjustment

Userts Manual. Digital micro pipette for liquid handling. In Vitro Medical Diagnostic Devices (98/79/EC) Annex III self-declared ISO 8655 STANDARD

Corning Step-R. Repeating Pipettor. Instruction Manual

Ultra-Low Copper Concentrations Determined by Rotating Disk Electrode Stripping Voltammetry

Accuracy and Precision

Hands-On Experiment Density and Measurement

Predicted Dispense Volume vs. Gravimetric Measurement for the MICROLAB 600. November 2010

User's Manual. Autoclavable Nichipet EX Plus Digital micro pipette for liquid handling CERTIFIED ISO9001

VITLAB Volumetric instruments

Before you start sampling, be sure to read

Ergonomic Pipetting for Problem Liquids!

LABORATORY TECHNIQUES. Pouring Liquids

Measurements. Metric System

Qi Litre Ultrasonic Cleaner

Calibrating Piston Pipettes

Laboratory Activity Measurement and Density. Average deviation = Sum of absolute values of all deviations Number of trials

CHM Introductory Laboratory Experiment (r17sd) 1/13

Transcription:

UNCC Biotechnology and Bioinformatics Camp Dr. Jennifer Weller Summer 2010

Using Micropipettes Lab Intro

Micropipettes How do you control volume in the microliter range? How do you verify that the volume delivered by such a device is accurate?

Use of Micro-pipettes

Introduction Micropipettes or Pipetteman Hand-held devices used to transfer small volumes Glass or plastic 1.0 ml pipettes are not highly accurate for volumes less than 0.1 milliliter, but the automatic pipettes are both accurate and precise. There are analog and digital models for setting the delivery volume Each pipette can be set to transfer any volume within its own volume range

Using Automatic Micropipettes Select the proper pipette to transfer the specified volume of sample Set the specified volume on the micropipette Read the digital volume setting correctly convert micro liter (µl) to milliliter (ml) units when necessary Demonstrate the correct technique to accurately transfer a sample of a stock solution to another vessel Verify the delivery volume by pipetting water onto a piece of film on a fine-scale balance

Parts of the Pipette and tips Pipette tips

Operating the Micropipette Step 1: select the correct pipetter Pipettors 3 Volumes: Step 2: Set the Volume Volume Adjustment Knob: Digital Volume Indicator:

Operating the Micropipette Read the Volume How to Read the Volume Indicator: (a): P-20 Model 6.86 m l = 0.00686 or 6.86 x 10-3 ml (b): P-200 Model 132.4 m l = 0.1324 or 1.324 x 10-1 ml (c): P-1000 Model 262 m l= 0.262 or 2.62 x 10-1 ml

Operating the Micropipette Step 2: Attach the Disposable Tip Attaching the disposable tip Example of tip sizes:

Operating the Micropipette Step 3: Depress the Plunger to the First Stop Step 4: Immerse Tip in Sample To pull the sample into the tip Step A.. 5: Allow Draw the up the pushbutton to return slowly and sample smoothly to the fully extended UP POSITION. NEVER LET THE PLUNGER SNAP UP! This draws the exact calibrated volume into the tip if the tip remains below the liquid surface Step 6: Pause during withdrawal. Wait a few seconds to ensure that the full volume of sample is drawn into the plastic tip. WAIT LONGER FOR LARGER VOLUMES. WAIT LONGER FOR MORE VISCOUS ("SYRUP-LIKE") SUBSTANCES.

Operating the Micropipette Remove Step 7: the Withdraw tip from the the sample Tip liquid. No liquid should remain on the OUTSIDE of the tip. Depending on the experiment you may wipe away any droplets on the outside of the tip with a lint-free tissue, such as KIMWIPES, but only wipe droplets from the side of the tip. NEVER TOUCH THE TIP OPENING or you may absorb part of your sample. Proper Droplet Removal WRONG Droplet Removal

Operating the Micropipette Dispense the Sample To dispense the sample from the pipette: a) Touch the tip end to the side wall of the receiving vessel and b) Depress the plunger to the FIRST STOP. c) Pause for at least one second-- 1-2 seconds for P-1000, 2-3 seconds for P-5000, or longer for viscous liquids. d) Press the plunger to the SECOND STOP (the second point, of greater resistance, at the bottom of the stroke) to expel any residual liquid in the tip (like "blowing out" a glass pipette). (a) Start Dispensing (b) 1st Stop = Dispense (c) 2nd Stop = Expel

Operating the Micropipette Step 9: Withdraw the Pipette With the plunger fully depressed, withdraw the pipet from the receiving vessel, sliding the tip along the wall of the vessel. Holding the tip against the side of vessel is especially important when transferring small volumes of liquid. Step 10: Release the Plunger Gently allow the plunger to return to the UP position. DO NOT allow it to SPRING BACK! Step 11: Discard the Tip Discard the tip by depressing the tip ejector button, as shown below. A fresh tip should be used for each sample to prevent sample carryover. Press ejector button to discard tip.

Equipment and Supplies 4 automatic pipettes and matching tips A blue-capped tube of water A piece of Parafilm to practice pipetting onto Gloves, Kimwipes

Step-wise Operation of the Automatic Pipette (1) Set the volume (2) Attach disposable tip (3) Depress the plunger to the first stop (4) Immerse tip in sample (5) Draw up the sample (6) Pause (7) Withdraw the tip (8) Dispense the sample (9) Withdraw the pipette (10) Release plunger (11) Discard the tip

Accuracy and Precision Accuracy means the closeness with which the dispensed volume approximates the volume set on the pipette Accuracy is specified as mean error, the average deviation of replicate measurements from the expected set volume Precision is the "scatter" or reproducibility of individual measurements of the same volume Precision can also be expressed as standard deviation

Accuracy and Precision (Continued) Relative accuracies are generally about 1% or less Precision is less than 0.5 % except when transferring the smallest recommended volume for a given pipette model Using the pipettes to transfer volumes which are below the recommended range will introduce larger errors

Pippetting Guidelines and Precautions For optimal reproducibility, use the following pipetting procedures: (1) Consistent SPEED and SMOOTHNESS when you press and release the PLUNGER (2) Consistent pressure on the PLUNGER at the FIRST STOP (3) Consistent and sufficient IMMERSION DEPTH (4) Nearly VERTICAL POSITIONING of pipette (5) AVOID ALL AIR BUBBLES: Since the plastic pipette shaft can be damaged if liquids are drawn beyond the tip into the shaft (6) NEVER lay the pipette on its SIDE nor INVERT the pipette if liquid is in the tip

Practice with Pipettes Practice using the pipette Practice setting a few volumes Practice reading the digits of set volumes Practice drawing up and dispensing samples Get the "feel" of the 1st and 2nd stops Practice "blowing out" the pipette

Verifying your pipetting skill Note: these micropipettes were recently calibrated Note: you do not have to change pipette tips unless you touch one to a surface. Put a piece of parafilm on the weighing tray of the Mettler Balance Tare the parafilm Pipette a series of volumes and record the mass. Record the model of pipetter also. 5ul, 7.5 ul, 14.5, 20ul,42.5ul and 75.8ul, 162.5ul.