Technology for Vacuum Systems Instructions for use

Similar documents
Technology for Vacuum Systems. Decontamination

Varipette Operating manual

GI Series Diaphragm Pressure Gauge Guard

Pressure relief valve

Siphon vessel / Priming aid

Technology for Vacuum Systems. Instructions for use

Transferpette. Testing Instructions (SOP) 1. Introduction. October 1998

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

Instruction Manual. CG16K Barometrically Compensated Capsule Dial Gauge. CG16K Capsule Dial Gauge, 0 to 25 mbar

Operating Manual VSA100A. tina29e1 ( )

Cavitron DualSelect. Introduction ENGLISH. Directions For Use. Cavitron DualSelect Dispensing System ENGLISH 1

Decontamination Procedures for Gilson Pipettes

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

Pressure relief valve

Type BBS-03, BBS-05, BBS-06, BBS-25

Model ASSEMBLY and OPERATING INSTRUCTIONS

Hydraulic Punch Drivers

OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER

Operating Instructions and Parts Manual 24529

Modular valve block. Operating manual Series MVB 100/200. Version BA EN Print-No TR MA DE Rev001

3M Liqui-Cel EXF-14x28 and 14x40 Series Membrane Contactor

Model Visit our website at:

BGA244 Binary Gas Analyzer

Hydraulic Punch Drivers

Lab Cock. Contents. User s Manual (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

TABLE OF CONTENTS. INTRODUCTION to the AirVAC... 2 SAFETY INFORMATION... 3 DIMENSIONS & SPECIFICATIONS... 5 UNIT OVERVIEW... 6

Flowmeter. Original operating manual DFM

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

Inverted Bucket Steam Trap IB 16A-7

Ball valve. Operating instructions for series. Version BA Print-No TR MA DE Rev001

30T A/Manual Hydraulic Shop Press

Type 3709 Pneumatic Lock-up Valve. Translation of original instructions. Mounting and Operating Instructions EB 8391 EN

Installation, Operating & Maintenance Instructions. Variable leak valve with manual actuator. Series 590 DN 16 mm (I. D. ⅝") E

Instruction Manual Contact Pressure Vacuum Gauge

PENBERTHY SUBMERSIBLE AUTOMATIC SUMP DRAINER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Non-Return Valve SRK 22A

VWR UHP j :01 Page 1. ENGLISH 1 22 DEUTSCH FRANÇAIS ESPAπOL ITALIANO

Flexi-pro Aerosol Delivery System (FADS) Manual

Declaration of Conformity as per Directive 97/23/EC

Laboratory Safety Training. Environmental Health and Safety

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Please read these instructions carefully before use! Please consider the safety instructions! Please keep for future reference!

Corning Step-R. Repeating Pipettor. Instruction Manual

Transferpette -8/-12

OPERATING MANUAL. Contents. Bottom outlet ball valve Type ecoline

3M Liqui-Cel EXF-4x13 and 4x28 Series Membrane Contactors

Sterile Visual Flow Indicator

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

Declaration of Conformity as per Directive 97/23/EC

PIPETMAN F ENGLISH. Other languages available on our website:

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies

REL-510H WARNING NOTICE 12 TON SINGLE ACTING REMOTE HYDRAULIC CRIMPING HEAD

Installation and Service Manual

Instructions for use Compressed air injector with water trap

USER MANUAL. 1. Principle of operation. 2. Delivery condition. SPRING-LOADED SAFETY VALVES zarmak. Edition: 07/2016 Date: V (ex.

User Guide. Pall Laboratory Manifold. For laboratory use. Not for use in a manner other than indicated. Introduction. Regulatory References

Transferpette. Lightweight precise rugged reliable!

Norrsken Family Booklet

Circular Sight Windows

User s Manual. Autoclavable & UV resistant. Multi-channel digital micro pipette. In Vitro Medical Diagnostic Devices (98/79/EC)

Pressure Relief Valve Instruction Manual

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

Transferpette. Lightweight precise rugged reliable!

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

20 Ton SD Shop Press Operating Instructions

Temperature gauge Installation Guide

Instructions for use Evacuation system compressed air injector SL 20 / SL 20 Max SL 30 / SL 30 Max

User Manual. Quantos Automated Dosing Liquid Module

Constant Pressure Crude Oil Container Model CPCCP

User s Manual. Autoclavable & UV r e s i s t a n t. Digital micro pipette for liquid handling. In Vitro Medical Diagnostic Devices (98/79/EC)

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

Operating Instructions Hand Test Pump BHP 700

Compact Ball Valves ASAHI AV VALVES. Contents. User s Manual. (Page) (1) Be sure to read the following warranty clauses of our product 1

Neotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions

Operating Instructions. Ball valve fitting according to ZB For pressure transmitter VEGABAR 82. Document ID: 50027

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

GILMONT ACCUCAL FLOWMETERS

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

35 TON HYDRAULIC PUNCH WARNING

ROPV R40 E Series User Manual

Model No Product Name Handpiece Only Complete System

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Brass Check Valve RDL

Transferpette. Testing Instructions (SOP) 1. Introduction. May 2009

User s Manual. Digital micro pipette for liquid handling CERTIFIED ISO9001

INSTALLATION COMMISSIONING, OPERATION & MAINTENANCE MANUAL

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

AQUARIUS. Operating Instructions for the. Type 70 Electrolytic Gas Soldering / Welding Unit. Table of Contents

Safety and operating instructions

DISASSEMBLING & REASSEMBLING CARTRIDGE INSTALLING SEATPOST ON BIKE

Swing Check Valve CB 14 CB 24S CB 26 CB 26A

Operating Manual ALU 7 - ALU 10 - ALU 20 - ALU 26 ALU 35 - ALU 60 - ALU 100

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

VITLAB micropipette. Standard Operating Procedure (SOP)

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

OFFICINE OROBICHE S.p.A. 1/9

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

FOR SAFE AND CORRECT USE

AIR/OVER HYDRAULIC JACK 20 TON

Declaration of Conformity as per Directive 97/23/EC

3M Liqui-Cel EXF-10x28 Series Membrane Contactor with ANSI or JIS Connections with Integrated End Caps

Transcription:

page 1 of 28 Technology for Vacuum Systems Instructions for use 8-channel tip adapter with ejector

page 2 of 28 After sales service: Contact your local dealer or call +49 9342 808-5500. Trademark index: VACUU LAN (US-Reg.No 3,704,401), VACUU BUS, VACUU CONTROL, Peltronic, VARIO (US-Reg.No 3,833,788), VACUUBRAND (US-Reg. No 3,733,388) and also the shown company logos are trademarks of VACUUBRAND GMBH + CO KG in Germany and/or other countries.

page 3 of 28 Contents Safety information!... 4 Important information!... 4 General information... 6 Intended use... 6 Ambient conditions... 7 Operating conditions... 7 Safety during operation... 8 Maintenance and repair... 9 Technical data... 10 Materials of the 8-channel adapter... 10 System parts...11 Use and operation... 12 Assembling the adapter... 13 Assembling the bench-top rack... 14 Prior to aspiration... 15 Aspiration of liquids... 15 Ejecting the tips... 16 After aspiration... 16 Cleaning and decontaminating... 18 Accessories and spare parts... 21 Troubleshooting... 22 Replacing the nose cones... 23 Repair - Maintenance - Return - Calibration... 24

page 4 of 28 Safety information! Important information! + Keep this manual complete and accessible to personnel at all times! + Read this manual carefully before installing or operating the equipment. Observe the instructions contained in this manual. + Do not modify the equipment without authorization. This manual is an integral part of the equipment described therein. It describes the safe and proper use of the equipment. Make operating personnel aware of dangers arising from the device and the used substances. VACUUBRAND disclaims any liability for inappropriate use of the equpment and for damage from failure to follow instructions contained in this manual. This manual is only to be used and distributed in its complete and original form. It is strictly the users responsibility to check carefully the applicability of the guidance in this manual with respect to his product. Manual-no.: 20901322 The following signal word panels and safety symbols are used throughout this manual: This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury and death.

page 5 of 28 DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. + WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. is used to address practices not related to personal injury. Formatting used in this manual: Note: The signal word panels in all sections of this manual always refer to all paragraphs of the same format ( / + / / plain text) following each signal word panel.

page 6 of 28 General information Read and comply with this manual before installing or operating the equipment. Before operating the equipment read and comply with the section Cleaning and decontamination! Remove all packing material, remove the product from its packing-box and inspect the equipment. If the equipment is damaged, notify the supplier and the carrier in writing within three days; state the item number of the product together with the order number and the supplier s invoice number. Retain all packing material for inspection. Do not use the equipment if it is damaged. Intended use + The device may only be used by well trained and skilled personnel. + The device may not be used for in vivo applications (e. g., not at humans or animals). Ensure that the equipment and all components are suitable for the intended application. Use the system only for aspiration of liquids. Setting up The 8-channel tip adapter with ejector is intended to be conntect to a VACUUBRAND VHC pro. The VHC pro is intended to be conntect to a suitable suction system, e. g., VACUUBRAND BVC systems. Comply with all applicable and relevant safety requirements (regulations and guidelines), implement the required actions and adopt suitable safety measures.

page 7 of 28 Ambient conditions The systems are designed for ambient temperatures during operation between +10 C and +40 C. Check the maximum temperatures. Operating conditions The devices are not suitable to aspirate: - flammable mixtures - unstable substances - substances which react explosively under impact (mechanical stress) and/or when being exposed to elevated temperatures without air, - self inflammable substances, - substances which are inflammable without air and - explosive substance The devices have no approval for operation below ground. The devices are not suitable for aspiration of dust. Take into consideration interactions and chemical reactions of the aspirated media. Ensure that the materials of the wetted parts are compatible with the aspirated substances, see section Technical data. If aspirating different substances, it is recommended that the aspiration hose be purged prior to changing the media in order to rinse out residues and to avoid reactions of the substances with each other and with the materials.

page 8 of 28 Safety during operation Ensure that while operating the device no persons can be endangered. Wear personal protection equipment. Comply with requirements when using infectious liquids, pathogenic germs, toxic, radioactive or aggressive substances. Prior to operation check all relevant safety and health requirements and determine the applicability of regulatory limitations prior to use if necessary. Comply with material safety data sheets and notes on safe use of the manufacturer. Comply with the biosafety level of the laboratory. Use appropriate safety work materials and methods if necessary, e. g., steam sterilization, sterilization indicators or germicides. For notes concerning the sterilization of wetted parts, see the Technical Data section and Cleaning and decontaminating. It is the user s responsibility to ensure effective sterilization. Never operate a defective or damaged device. Comply with applicable regulations when disposing of chemicals. Take into consideration that chemicals may be polluted. Use only OEM spare parts and accessories; otherwise safety and performance of the equipment as well as the electromagnetic compatibility of the equipment might be reduced. In case of leaks, aspirated substances might be released into the environment. Comply especially with notes on operation and use. Ensure that, in case of failure, the system will always return to a safe status. Provide appropriate protective measures (i.e., precautions which allow for the requirements of the respective application) even for the case of failure and malfunction.

page 9 of 28 Maintenance and repair Attention: The device might be contaminated with noxious or otherwise dangerous substances that have been aspirated during operation. Ensure that the device is decontaminated before maintenance. Take adequate precautions to protect people from the effects of dangerous substances if contamination has occurred. Wear appropriate safety-clothing when you come in contact with contaminated components. Ensure that maintenance is done only by suitably trained and supervised technicians. Ensure that the maintenance technician is familiar with the safety procedures which relate to the products processed by the system. In order to comply with law (occupational, health and safety regulations, safety at work law and regulations for environmental protection) vacuum pumps, components and measuring instruments returned to the manufacturer can be repaired only when certain procedures (see section Repair - Maintenance - Return - Calibration ) are followed.

page 10 of 28 Technical data Type Permissible ambient temperature storage / operation Autoclaving F C 8-channel tip adapter with ejector 14 to 140 / 50 to 104 (-10 to +60 / +10 to +40) 121 C and 2 bar absolute (1 bar overpressure) Adapter for pipette tips 2-200 µl and 5-300 µl Distance between nose cones mm 9 Dimensions L x W x H approx. mm 80 x 42 x 118 Weight approx. g 80 Materials of the 8-channel adapter Wetted parts Stainless steel, PP with and without glass fibre, PPS, PVDF, FKM, EPDM, silicone Not wetted parts Stainless steel, PTFE with carbon, PP with and without glass fibre, PPS with glass fibre We reserve the right for technical modifications without prior notice!

page 11 of 28 System parts Position Designation 1 nose cone with O-ring 2 ejector 3 screw cap 2 3 1

Use and operation page 12 of 28 Unpack the equipment. Scope of delivery 1 3 2-8-channel adapter (1) - bench-top rack (2) - mounting tool for nose cones (3) - reagent reservoir / bowl for disinfectant (4) The 8-channel tip adapter with ejector is intended to be connected to a VACUUBRAND VHC pro. 4

page 13 of 28 Assembling the adapter Ensure that there is no liquid in the tube to avoid risk of contamination. Aspirate until the aspiration tube is empty and decontaminate if necessary. Select continuous aspiration. We recommend to switch off vacuum supply or to close connection to the vacuum supply. Remove pipette if necessary. Attention: Liquid in the tube may leak. Adopt suitable measures to prevent the release of dangerous, toxic, explosive, corrosive, noxious or polluting fluids, vapors and gases. In such cases, use an appropriate collecting and disposal system and take protective action for personnel, equipment and environment. 2 1 Turn cap (1) and remove (2). Pull existing adapter with hose out of the VHC pro. Remove adapter from hose.

page 14 of 28 Attach 8-channel adapter to the hose. Pull the 8-channel adapter with hose back in the VHC pro. Obey mark at the cap when reassembling the cap. Screw cap hand tight. Set the VHC pro to Aspiration if necessary. Assembling the bench-top rack Stick together the both halves of the bench-top rack correctly. Attention: It is not possible to disassemble the bench-top rack nondestructively.

page 15 of 28 Prior to aspiration Insert pipette tips. Ensure that the tips are securely seated. Align the adapter. The adapter can turn freely in both directions. Attention: Pipette tips are disposables items. Never insert filled pipettes due to risk of contamination and infection. Wear protective gloves! Aspiration of liquids Use only appropriate vessels. Dip pipette tip into the liquid. Setting aspiration at the VHC pro : Press the lever until the liquid has been aspirated. Release the lever to stop aspiration. Setting continuous aspiration at the VHC pro : In setting continuous aspiration it is not necessary to press the lever. Remove pipette from liquid to stop aspiration. If necessary set the adjusting knob to Aspiration to stop continuous aspiration.

page 16 of 28 Ejecting the tips Hold the device over a suitable disposal container and press the ejector to the stop. Don t lay the instrument horizontal when the tips are filled. Liquid may enter and contaminate the instrument or the environment. After aspiration At the end of aspiration, continue to aspirate until there is no more liquid in the aspiration tubing and purge with cleaning or disinfectant agent (suck through) if necessary. Use reagent reservoir / bowl for disinfectant (enclosed in delivery) if necessary. Eject pipette tips. Attention: Risk of contamination and infection. Wear protective gloves and eye protection! Dispose of pipettes according to appropriate regulations.

page 17 of 28 We recommend to store the device without tips, placed upright in the supplied bench-top rack.

page 18 of 28 Cleaning and decontaminating Autoclaving The VacuuHandControl VHC pro with adapters and aspiration hose is designated for steam sterilization at 121 C and 2 bar absolute (1 bar overpressure). Time of exposure according to DIN 58946 t e = 20 minutes. Ensure not to exceed a temperature of 121 C. Comply with instructions for use of the manufacturer of the autoclave. It is the user s responsibility to ensure effective autoclaving. Prior to autoclaving set the VHC pro to autoclaving. Prior to autoclaving loose the cap. After autoclaving tighten the nose cones if necessary with the mounting tool (enclosed in delivery), see section Replacing the nose cones.

page 19 of 28 It is not possible to disassemble the 8-channel adapter completely. It is possible to replace the nose cones, see section Replacing the nose cones. It is not possible to disassemble the VHC pro completely. It is possible to disassemble and replace the adapters, the screw cap and the aspiration hose, see manual of the VHC pro. If the housing opens lightly by mistake, e. g., if the handle is fallen down, press the gap together by hand. Perform a function test. Pursept A Chemical disinfection A wiping and spray disinfection is possible by using the germicide Pursept A. Over time, discoloration and material changes (e.g., resiliency, elasticity/tightness, cracking) due to repeated steam sterilizations may occur.

page 20 of 28 Important notes on use of disinfectants Aggressive disinfectants which release chlorine or oxygen radicals, e.g., sodium hypochlorite (chlorine bleach) or peroxide compounds can corrode the materials. Therefore, prolonged use of these disinfectants is strongly discouraged. After brief disinfecting operations, rinse thoroughly to avoid leaving residues of disinfectant. The use of the disinfectant Sekusept Plus (Manufacturer: Ecolab GmbH & Co OHG, Düsseldorf, Germany) in extensive in-house testing did not cause any damage. Hence the disinfectant Sekusept Plus is preferred. Comply with use and safety instructions of the manufacturer! Using corrosive disinfectants may result in damage, malfunction and/or failure of the equipment. Chlorine may damage the materials of the equipment or the vacuum supply. Leaking of liquid from a damaged aspiration system may lead to exposure of personnel and material or to damage/destruction of wetted equipment or laboratory furniture. For information about the compatibility with the materials, ask the manufacturer of the disinfectant. The materials of the system are listed in the section Technical data.

page 21 of 28 Accessories and spare parts Set of nose cones (8 pieces)...20635589 with O-rings and mounting tool 8 x 1 x Bench-top rack for 8-channel tip adapter...20635584 VacuuHandControl VHC pro...20688061 Spare hose for VHC...20636156 (minimum order quantity 2 m) For further accessories and spare parts see manual of the VHC pro. Pipettes or pipette tips are available from BRAND GMBH + CO KG (www.brand.de/en) via laboratory products distributors.

Troubleshooting page 22 of 28 Fault Possible cause Remedy No aspiration at the VHC pro. Pipette drips. Adapter or aspiration Replace adapter with tube defective? aspiration hose. Aspiration hose kinked? Correct hose guide. Pipette does not held properly in the adapter. Liquid is aspirated slowly or not at all. Aspiration hose clogged or agglutinated? Pipette fits loosely or fits bad? Leak in the system? No vacuum? Adapter wet or greasy? Pipette with improper diameter selected? Seal at the nose cone defective? Pipette or nose cone clogged or damaged? Remove clogged or agglutinated hose section or replace hose. Connect pipette securely or choose an appropriate adapter. Check the system for leaks. Check the vacuum system. Clean or replace adapter. Choose appropriate pipette or change adapter. Replace nose cone. Clean or replace pipettes or nose cones.

page 23 of 28 Replacing the nose cones Tools required: - Flat-bladed screw driver or coin - Mounting tool for nose cones Turn both closures of the housing cover 90 (e.g., using a coin). Slide off the housing. Use the mounting tool to unscrew the nose cone. Position new nose cone and screw hand-tight using the mounting tool. Reassemble the 8-channel adapter.

page 24 of 28 Repair - Maintenance - Return - Calibration IMPORTANT Every employer (user) is held responsible for the health and safety of his employees. This also applies to service personnel performing repair, maintenance, return or calibration. The health and safety clearance form informs the contractor about any possible contamination of the device and forms the basis for the risk assessment. In case of devices which have been in contact with biological substances of risk level 2 contact the VACUUBRAND service absolutely before dispatching the device. These devices have to be completely disassembled and decontaminated by the user prior to shipment. Do not return devices which have been in contact biological substances of risk level 3 or 4. These devices cannot be checked, maintained or repaired. Also decontaminated devices must not returned to VACUUBRAND due to a residual risk. The same conditions apply to on-site work. No repair, maintenance, return or calibration is possible unless the correctly completed health and safety clearance form is returned. Devices sent are rejected if applicable. Send a completed copy of the health and safety clearance form to us in advance. The declaration must arrive before the equipment. Enclose a second completed copy with the product. Remove all components from the device that are no original VACUUBRAND components. VACUUBRAND will not be responsible for lost or damaged components that are no original components. Drain the device completely of fluids and residues. Decontaminate the device. Close all openings airtight especially if using substances hazardous to health.

page 25 of 28 To expedite repair and to reduce costs, please enclose a detailed description of the problem and the product s operating conditions with every product returned. If you do not wish a repair on the basis of our quotation, the device may be returned to you disassembled and at your expense. In many cases, the components must be cleaned in the factory prior to repair. For cleaning we use an environmentally friendly water based process. Unfortunately the combined attack of elevated temperature, cleaning agent, ultrasonic treatment and mechanical stress (from pressurised water) may result in damage to the paint. Please mark in the health and safety clearance form if you wish a repaint at your expense just in case such a damage should occur. We will also replace parts for cosmetic reasons at your request and at your expense. Before returning the device Pack the device properly, if necessary, please order original packaging materials at your costs. Mark the package completely Enclose the completed health and safety clearance form. Notify the carrier of any possible contamination if required. Scrapping and waste disposal Dispose of the equipment and any components removed from it safely in accordance with all local and national safety and environmental requirements. Particular care must be taken with components and waste oil which have been contaminated with dangerous substances from your processes. Do not incinerate fluoroelastomer seals and O-rings. You may authorize us to dispose of the equipment at your expense. Otherwise we return the device at your expense.

page 26 of 28 Health and safety clearance form 1. Device (Model):... 2. Serial no.:... 3. Reason for return / malfunction:...... 4. Has the device been used in a copper process step (e.g., semiconductor production): yes no 5. Substances (gases, liquids, solids, biological material, e. g. bacteria, viruses) in contact with the device / which have been pumped:............ 6. Risk level of the used biological material: none 1 2* 3** 4** * Contact the VACUUBRAND service absolutely before dispatching the device. ** Devices which have been in contact with biological substances of risk level 3 or 4 cannot be checked, maintained or repaired. Also decontaminated devices must not returned to VACUUBRAND due to a residual risk. 7. Radioactive contamination: yes no 8. Prior to return to the factory the device has been decontaminated: yes no Description of the decontamination method and the test / verification procedure:...... 9. All parts of the device are free of hazardous, harmful substances: yes no 10. Protective measures required for service staff:... 11. If the paint is damaged, we wish a repaint or a replacement of parts for reason of appearance (repaint and replacement at customer s expense): yes no 12. Legally binding declaration We assure for the returned device that all substances, which have been in contact with the device are listed in section 5 and that the information is complete and that we have not withheld any information. We declare that all measures - where applicable - have been taken listed in section Repair - Maintenance - Return - Calibration. By our signature below, we acknowledge that we accept liability for any damage caused by providing incomplete or incorrect information and that we shall indemnify VACUUBRAND from any claims as regards damages from third parties. We are aware that as expressed in 823 BGB (Public Law Code of Germany) we are directly liable for injuries or damages suffered by third parties, particularly VACUUBRAND employees occupied with handling/repairing the product. Shipping of the device must take place according to regulations. Name:... Signature:... Job title:... Company s seal: Date:... Release for repair grant by VACUUBRAND (date / signature):... Protective measures: Protective gloves, safety goggles Hood External cleaning VACUUBRAND GMBH + CO KG Alfred-Zippe-Straße 4 97877 Wertheim - Germany T +49 9342 808-5660 F +49 9342 808-5666 E-Mail: service@vacuubrand.com www.vacuubrand.com

page 27 of 28

page 28 of 28 Disclaimer: Our technical literature is only intended to inform our customer. The applicability of general empirical values and results obtained under lab conditions to your specific operations depends on a number of factors beyond our control. It is, therefore, strictly the users responsibility to very carefully check the application of these data to their specific requirements. No claims arising from the information provided in this literature will, consequently, be entertained. Alfred-Zippe-Str. 4 97877 Wertheim / Germany T +49 9342 808-0 F +49 9342 808-5555 info@vacuubrand.com www.vacuubrand.com VACUUBRAND GMBH + CO KG - Technology for Vacuum Systems - 2018 VACUUBRAND GMBH + CO KG Printed in Germany Manual-no.: 20901322 / 07/01/2018