CC20 Series Tychem Hood Head Protection Respiratory Protection Fire and Rescue Safety Thermal Imaging Simple, Effective, Ultra-Light The CC20 Series Tychem Hood provides a wide variety of simple, effective and economical options for on-the-job respiratory protection. The result is better protection, improved productivity and greater comfort that combines to produce the best value on the market. These hoods are available for use in a CC20 Series Airline Respirator configuration or Powered Air Purifying Respirator configuration. Approved by NIOSH for use in Type C applications, the CC20 Series is used in a wide variety of industries including: pharmaceutical manufacturing chemical and pesticide handling spray painting and coating operations nuclear operations Proven Performance In a 996 study of hood-style respirators coordinated by the Organization Resources Counselors (ORC), the Bullard CC20 hood was surveyed to be the number one hood used in the pharmaceutical industry. The most commonly used hoods were then used in a simulated workplace protection factor study (SWPF). The Bullard CC20 hood was also the top-performing loose- hood among a variety of competitors. All measurements in the SWPF study were above 50,000 resulting in a study Assigned Protection Factor (APF) of 0,000! For a summary of this research, call Bullard customer service at -800-827-042. www.bullard.com
Features and Benefits Unique Air Delivery System A patented neck cuff design helps maintain positive pressure inside the hood to aid in keeping contaminants out. As air enters the hood, the inner collar inflates, providing a snug, comfortable fit around the neck and continuous flow of air to the worker s breathing zone. Lightweight, Comfortable and Economical The CC20 hood is lighter and more comfortable than tight- full facepiece respirators. Covering the entire head, face and neck, the CC20 hood provides splash/overspray protection and makes clean-up quick and easy. A wide angle lens offers the largest field of vision among Tychem hood-style respirators on the market, optimizing worker productivity and safety. Available in a variety of styles, the CC20 hood is constructed of either Tychem QC or Tychem SL depending on the job application. Taped and sealed seams are also available to provided additional protection for liquid penetration encountered on-the-job or during decontamination. Reusable or Disposable CC20 respirator hoods are durable enough to reuse, yet economical enough to discard after each use, depending on the work application. No Fit Testing The CC20 hood does not require fit testing nor extensive recordkeeping. It easily accommodates beards, prescription eyewear or safety glasses. Powered Air or Supplied Air The CC20 hood is a available for use as a supplied air respirator (CC20 series) or powered air respirator (PA20 series). A versatile hood suitable for almost any application.
WARNING This hood is only one component of a CC20 or PA20 respirator system. By itself, the hood does not constitute a complete respirator. Read all instructions and warnings before using this respirator hood. Improper respirator use could result in death or serious injury, or may cause certain delayed lung diseases such as silicosis, pneumoconiosis or asbestosis. These diseases may cause death. If you have questions on how to use this respirator, ask your employer. Do not wear this respirator in any atmosphere immediately dangerous to life or health (IDLH), or from which you cannot escape without the aid of the respirator. Do not wear the PA20 respirator in any atmosphere containing less than 9.5% oxygen. If you are not sure whether the atmosphere is IDLH or oxygen deficient, ask your employer. Prior to each use of this respirator system, BE CERTAIN of the following: FOR CC20 AIRLINE RESPIRATORS AIR SUPPLY: Grade D Breathable Air, as described in the Compressed Gas Association Commodity Specifications G7., must be continuously supplied to the pointof-attachment. The point-of-attachment is the point at which the air supply hose connects to the air source. A pressure gauge attached to the air source is used to monitor the pressure of air provided to the respirator wearer. AIR SOURCE: Be sure to locate the source of compressed breathing air in a clean air environment. Locate the air source far enough from your work site to ensure the air remains contaminant free. AIR PRESSURE at the point-of-attachment must be continuously maintained within the pressure ranges certified on the NIOSH Approval Label that appears in the User Manual supplied with the original factory packaged system and on the table on the reverse side of this label. NIOSH-APPROVED BULLARD AIR HOSE(S) must be used between the breathing tube connection on the wearer s belt and the point-of-attachment to the air supply system. APPROVED FITTINGS must be used to connect hose lengths together. Total connected hose lengths and number of sections must be within the ranges specified on the NIOSH Approval Label and on the table on the reverse side of this label. BELT AIR CONNECTION FITTINGS must be attached to your belt or the separate belt supplied with the system to help keep the air supply hose from snagging, disconnecting or pulling the hood off your head. PROTECTION HEAD Only the respirator models 20TICH and 20SICH provides head protection when used with a Bullard hard hat. EARS CC20 and PA20 respirators DO NOT provide hearing protection. Use properly fitted earmuffs, earplugs or other protection when exposed to high noise levels. EYES CC20 and PA20 respirators DO NOT provide eye protection. Wear approved safety glasses or goggles at all times. TYCHEM There are uses, environments and chemicals for which this garment is not suitable. It is the responsibility of the user and the employer to determine that this garment is appropriate for the intended use. This material should not be used around heat, open flames, sparks or in any potentially flammable or explosive environment. This material will burn and will melt. DuPont Tychem spunbonded olefin apparel fabrics have Class - Normal Flammability characteristics, as tested according to the Flammable Fabrics Act. Class fabrics will burn and do not provide thermal protection if a fire or CC20 Series Tychem Hood Hood style respirator does not require fit testing and also allows for facial hair and eyewear. Replaceable snap-in suspension provides ultimate comfort, and maintains the field of vision during activities. Wide angle lens offers the best visibility in the industry. Optional taped and sealed seams for added protection. Patented inflatable neck cuff design provides superior, comfortable protection, while delivering airflow directly into the worker s breathing zone. Bullard CC20 and PA20 Respirators explosion should occur Pony tail tag on every hood provides information on replacement parts, user guidelines, and required pressures. Optional inner bib provides added protection and some cooling of the torso Climate control options allow the user to heat or cool the incoming air by as much as 0º F for comfort and productivity.
CC20 Series Airline Respirator Selection Select one of each of the following four components: Respirator Hood CC20 Series respirator hoods are made of tough, durable Tychembased materials and feature a wide-angle lens for excellent peripheral vision. Choose the hood style that is best suited for the work application. Basic Style 20TJN, 20TPN Long Outer Bib Style With Tapered Seams 20TICN, 20TPCN 20SICN, 20TICSN 20SICH 2, 20TICH 2 Material Choices Tychem QC - Tychem coated with polyethylene provides excellent splash protection against many acids, bases and other liquid chemicals. Tychem SL - (Used on SICN hood only) Tychem coated with Saranex TM 2-P provides protection against an even wider range of chemicals. 2 Headband or Hard Hat Headband style with.020" lens, 2 Hard hat style with.040" lens Headband style with solvent resistant.00 mylar lens Choose a or hard hat to keep the hood secure and stable. The hard hat meets ANSI Z89.-986 Class A and B requirements for impact, penetration and dielectric protection. All models come with Sportek browpad. Standard Headband 20TG Standard with rear slide adjustment Sure-Lock Ratchet Headband 20RT with rear adjustment knob Model 000R Hard Hat 000R (ESRTSL) Model 000 Hard Hat 000 (ESULTRA) Model 500 Hard Hat 500 (TG600) Model 500R Hard Hat 500R (TGRT600) with Optional Climate Control Choose the breathing tube assembly appropriate for the work application and breathing air source. Assemblies available with constant or adjustable airflow and a variety of quickdisconnect s. Climate control devices are available to cool or warm incoming air. V0 Series Constant Flow Includes breathing tube, /4" quickdisconnect and belt. V40 Series Adjustable Flow Includes breathing tube, /4" quick disconnect, flow control valve and belt. For use with Breathing Air Compressors AC000 Series Cool Tube Includes /4" quickdisconnect and belt.* Adjustable Flow Climate Control Devices HC2400 Series Hot/Cold Tube Includes /4" quickdisconnect and belt.* DC5040 Series Dual-Cool Includes /4" quickdisconnect and belt. For use with a cooling vest.* V5 Series Constant Flow Includes breathing tube, /2" quickdisconnect and belt. For use with Ambient Air Pumps Frigitron 2000 Series Adjustable Flow Cool Tube * Includes /2" quickdisconnect and belt. *Can only be used with Bullard EDP0 or ADP20 pump. 4 Breathing Air Supply Hose The breathing air supply hose connects the breathing tube assembly to the air source. Choose the air supply hose suitable for the air source. Available in different lengths. V0 Series V0 Extension Hose Kits in 25' (7.6 m), 50' (5.2 m) and 00' (0.5 m) lengths. Maximum total length = 00 ft. V0 Series Starter Hose Kits in 25' (7.6 m) length. For use with Breathing Air Compressors V5 Series Starter/Extension Hose Kits in 25' (7.6 m) and 50' (5.2 m) lengths. Maximum total length = 50 ft. V20 Series For use with Ambient Air Pumps Starter/Extension Hose Kits in 50' (5.2 m) and 00' (0.5 m) lengths. Maximum total length = 00 ft. Air Source Air Source Breathing Air Compressor Bullard Free-Air Pump
Powered Air Purifying Respirator System Select one of each of the following four components: Respirator Hood CC20 Series respirator hoods are made of tough, durable Tychembased materials and feature a wide-angle lens for excellent peripheral vision. Choose the hood style that is best suited for the work application. Basic Style 20TJN, 20TPN Long Outer Bib Style With Tapered Seams 20TICN, 20TPCN 20SICN, 20TICSN 20SICH 2, 20TICH 2 Material Choices Tychem QC - Tychem coated with polyethylene provides excellent splash protection against many acids, bases and other liquid chemicals. Tychem SL - (Used on SICN hood only) Tychem coated with Saranex TM 2-P provides protection against an even wider range of chemicals. 2 Headband or Hard Hat Headband style with.020" lens, 2 Hard hat style with.040" lens Headband style with solvent resistant.00 mylar lens Choose a or hard hat to keep the hood secure and stable. The hard hat meets ANSI Z89.-986 Class A and B requirements for impact, penetration and dielectric protection. All models come with Sportek browpad. Standard Headband 20TG Standard with rear slide adjustment Sure-Lock Ratchet Headband 20RT with rear adjustment knob Model 000R Hard Hat 000R (ESRTSL) Blower Choose a PA or PA2 blower assembly. All blower assemblies include a breathing tube with clamp, filter and gasket, comfort belt, and airflow indicator. 4 Battery Chargers PASMC Quick Charger with trickle charge capability. PASTC Standard Charger PA2SMC Quick Charger with trickle charge capability. PA2STC Standard Charger PA20 Replacement Parts Model 000 Hard Hat 000 (ESULTRA) Model 500 Hard Hat 500 (TG600) Model 500R Hard Hat 500R (TGRT600) PA Blower with 0-hour battery and low voltage alarm. PA2 Blower with 6-hour battery. PAFG -pack of HEPA filters with gaskets PAFGBP 6-pack of HEPA filters with gaskets PAEB Extension belt for standard belt PADB All vinyl belt for decontamination PADEB Extension belt for decon belt
Ordering Information CATALOG NUMBER Respirator Hoods DESCRIPTION Basic Style Hoods 20TJN Tychem QC, no suspension 20TPN Tychem QC, no suspension, solvent resistant lens Hood with inner bib, for use with 20TICN Tychem QC, no suspension 20TPCN Tychem QC, no suspension, solvent resistant lens Hood with inner bib, for use with hard hat 20TICH Tychem QC, hard hat not included 20SICH Tychem SL, hard hat not included Hood with inner bib and long outer bib, for use with 20TICSN Tychem QC, taped and sealed seams, no suspension 20SICN Tychem SL, taped and sealed seams, no suspension Accessory Item for All Hoods 20LCL Mylar lens covers (25/pkg) Headbands and Hard Hats 20TG Standard 20RT Sure-Lock ratchet 000 Hard hat with standard suspension, white 000R Hard hat with ratchet suspension, white Accessories for Headbands and Hard Hats ES-ULTRA Standard replacement suspension for 000 hard hat ESRTSL Replacement ratchet suspension for 000R hard hat 20NC Chin strap for 20TG and 20RT s ES42 Chin strap for 000 and 500 hard hats Powered Air Purifying Respirator Components Blower PA Complete Blower with 0 hour battery and Low Voltage Alarm PA2 Complete Blower with 6 hour battery Battery Chargers PASMC Quick Charger for PA PASTC Standard Charger for PA PA2SMC Quick Charger for PA2 PA2STC Standard Charger for PA2 Replacement Parts and Accessories PAAF Air Flow Indicator PAFG Filter/Gasket (pack of ) PAFGBP Filter/Gasket (pack of 6) PABT for Heads (26" standard length) PABTXS for Heads (22" length) PADB Decon Belt/Comfort Pad PADEB Decon Extension Belt CATALOG NUMBER Suplied Air Respirator Components 20BT Breathing tube only (for supplied air) Assemblies (for supplied air) Include breathing tube, airflow control device, quickdisconnect nipple and belt. (Note: 20BT + F0 = V0) Constant Flow for use with Breathing Air Compressors (Schrader and Snap-Tite also available) V0 With /4" Industrial Interchange steel (Hansen Constant Flow Assemblies for use with Bullard Free-Air Pumps V5 With /2" Industrial Interchange, steel (Hansen Adjustable Flow for use with Breathing Air Compressors (Schrader and Snap-Tite also available) V40 With /4" Industrial Interchange, steel (Hansen Replacement Parts for S805 Nylon breathing tube clamp 462 Belt, Nylon webbing Flow Control Device Flow Control Valves F0 Constant flow control valve with /4" Industrial Interchange (Hansen compatible) quick-disconnect nipple (other industrial s available) F40 Adjustable flow control valve with /4" Industrial Interchange (Hansen compatible) quick-disconnect nipple (other industrial s available) F5 Constant flow control valve with /2" Industrial Interchange (Hansen compatible) quick-disconnect nipple Climate Control Assemblies For use with Breathing Air Compressors Cold Tubes Adjustable Flow (Schrader and Snap-Tite also available) AC000 DESCRIPTION With /4" Industrial Interchange steel (Hansen Hot/Cold Tubes - Adjustable Flow (Schrader and Snap-Tite also available) HC2400 With /4" Industrial Interchange steel (Hansen CATALOG NUMBER DESCRIPTION DUAL-COOL - Climate Control Device DC5040 With /4" Industrial Interchange steel (Hansen. Includes CH60 connector hose and nylon belt (Order vest separately). DC70M/L Medium/Large cooling vest DC70XL/XXL X-Large/XX-Large cooling vest Replacement Parts for Climate Control Assemblies MV2400 Muffler/valve assembly for HC2400 CH60 Connector hose for use with DC5040 Climate Control for use with Bullard EDP0 or ADP20 Free-Air Pump Cool Tube - Adjustable Flow Frigitron With /2" Industrial Interchange steel 2000 (Hansen. Air Supply Hoses and Fittings V0 Series Starter Hose Kits for use with Breathing Air Compressors (Schrader and Snap-Tite also available) Include 25' (7.6 m), /8" I.D. rubber hose with /4" female quick-disconnect coupler and V adapter (/8" hose-to- /8" pipe) 4696 With /4" Industrial Interchange steel (Hansen compatible) quick-disconnect coupler V0 Series Extension Hose Kits for use with Breathing Air Compressors Include /8" I.D. rubber hose, V hose-to-hose adapter and V hose-to-pipe (/8" hose-to-/8" pipe) 5454 25' (7.6 m) Extension hose kit 5457 50' (5.2 m) Extension hose kit 5458 00' (0.5 m) Extension hose kit V5 Series Coiled Hoses for use with Breathing Air Compressors (Schrader and Snap-Tite also available) Include /8" I.D. Nylon coiled hose with /4" female quickdisconnect coupler and /4" male quick-disconnect nipple V5250 25' (7.6 m) with /4" Industrial Interchange steel (Hansen compatible) s V5500 50' (5.2 m) with /4" Industrial Interchange steel (Hansen compatible) s V20 Series Hoses for use with Bullard Free-Air Pumps Include /2" I.D. rubber hose with /2" Industrial Interchange (Hansen compatible) female quick-disconnect coupler and /2" male quick-disconnect nipple V2050ST 50' (5.2 m) V2000ST 00' (0.5 m) WARNING Distributed by CC20 respirators are not approved for use in any atmosphere immediately dangerous to life or health (IDLH) or from which the wearer cannot escape without the use of a respirator. Bullard products are manufactured and tested to exacting specifications. Any alteration or modification of these products by the user may adversely affect product performance and voids all product certifications. This data sheet is in summary form only for easy reference. Refer to labels and instructions accompanying the product for more complete details regarding use, maintenance, warnings and limitations. Failure to use complete NIOSH-approved Bullard components and replacement parts voids approval of entire assembly. Bullard 898 Safety Way Cynthiana, KY 40-90 Toll free: +877-BULLARD (285-527) Tel: +859-24-666 Fax: +859-24-8987 www.bullard.com Bullard GmbH Hochkreuzallee 6 575 Bonn-Bad Godesberg Germany Tel: +49 228 99 0 Fax: +49 228 99 50 ISO 900 certified 2002 Bullard. All rights reserved. Bullard, Free-Air, and Sure-Lock are registered trademarks of Bullard. It s your life and you re worth it is a trademark of Bullard. Tychem is a registered trademark of the DuPont Company 4062 (0702) ISO 900 C ertifi ed