Coal Mine Change-Over-Stationg

Similar documents
Standalone Scrubber. MineARC AirGEN Standalone Scrubber AG-35. Emergency refuge chambers and auxiliary mining products.

Management System. Compressed p Air

Chemical Safe Havens. The MineARC ChemSAFE Utility Design Range

Chemical Safe Havens The MineARC ChemSAFE Standard Design Range

Hard Rock Mine Refuge Chambers

Hard Rock Mine Refuge Chambers

Refuge Chambers. Permanent. Permanent refuge solutions for underground safety zones, excavations and break/rest areas.

Chemical Safe Havens. The MineARC ChemSAFE Standard Design Range

MineARC s TunnelSAFE Multi-Service Vehicle (MSV) Refuge Chamber

Emergency shelters and effect on rescue plans

Strata REFUGE Solutions. for MINES, TUNNELS, CHEMICAL PLANTS, & SURFACE OPERATIONS

UNDERGROUND REFUGE REFUGE CHAMBERS 2017

Dräger Mine Refuge Chamber MRC 5000 Innovative, portable life support system

Self-Rescue Equipment and Skill Development for Mine Escape

Petrochemical Safe Havens

ChargeAir TM. System Developments in SCBA-Based Escape Equipment. Draeger Safety Inc. Engineered Solutions

6A.004 SCBA MAINTENANCE. Policy Number. Page 1 of 5 SCOPE

Ocenco Incorporated. M-20 Self Contained Self Rescuer Instruction Manual

Dräger ERS-Chamber Refuge Chambers

Emergency Refuge Chambers

Technical equipment and operation for a refuge room in: Shaft Konrad Mine.

At your side in the mining industry

Dräger ERS-Chamber Refuge Chambers

This written Compressed Gas Plan is kept at the corporate office and in the written Safety & Health Program.

INSTRUCTION MANUAL FOR EBA MINUTE SELF-CONTAINED SELF RESCUER (SCSR) Manual Number: NH13747 Revision: A, ECN 2384 September 7, 2001

Australian/New Zealand Standard

D At your side in the mining industry

B-Series. breathing air systems flow capacity: scfm

Confined Space. A Death Trap in Waiting. Technical Article

exceeds global breathing air quality standards B 1 breathing air systems flow capacity: scfm flow capacity: scfm ( Nm 3 /hr)

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION

Australian/New Zealand Standard

Breathing Air Purifiers. Comply with European Pharmacopoeia and International Breathing Air Standards

Working in Gas Hazard Areas

Vision Painting Inc Safety Management System

Safety Manual Section 6 Confined Space

Texas Department of Insurance. Respiratory Protection. Provided by. Workers Health & Safety HS01-027B (1-06)

Getting out safely Our escape solutions FILTERING ESCAPE EQUIPMENT COMPRESSED AIR EQUIPMENT OXYGEN SELF-RESCUER REFUGE CHAMBERS TRAINING & SERVICE

OCENCO M-20.3 Capacity 1 - Closed Circuit Escape Respirator (CCER) Emergency Escape Breathing Device (EEBD)

EMERGENCY BREATHING Military, Commercial & Corporate

DRÄGER REFUGE SHELTERS. Light in the middle of the tunnel

Personnel Protective Equipment

Breathing apparatus. Compulsory Specification for. Published by Government Notice No. R. 370 (Government Gazette 25040) of 20 March 2003

STAGE I: FORMATION ( )

Southern Districts Emergency Escape System

INSTRUCTION MANUAL EBA-75 CLOSED-CIRCUIT ESCAPE RESPIRATOR (CCER) CAPACITY 3

COMPANY MEMBERS: All privates, engineers, lieutenants, and captains who are assigned to fire and/or rescue companies.

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

Dräger Engineered Refuge Solutions Unmatched flexibility and mine safety

INSTALLATION AND OPERATION OF THE HYPERBARIC CHAMBER

MSA AUER SSR 30/100 MSA AUER SSR 30/100 B

Model XSMKIT. Operations and Instructions WARNING

Borden Gold Project. Worker Protection Strategy, & Emergency Response John JY Young Peter Calnan. April 20 th 2017

Salt Lake Community College

Respiratory Protection Self-Inspection Checklist

Compressed Gas Cylinders - Guideline

Breathing Air Purifiers Comply with OSHA Grade D, NFPA-99, European Pharmacopoeia and other International Breathing Air Standards

SRL Series. Oil-less Scroll Air Compressors. Pharmaceutical. Research & Development. Food & Beverage. Chemical. Electronic

Breathable Compressed Air

Operating Manual MSA SSR 30/100 / MSA SSR 30/100 B EN K/20/S. Order No /01. MSAsafety.com

National Personal Protective Technology Laboratory

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

Respiratory Protection Self Inspection Checklist

1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS

STANDARD OPERATING PROCEDURE

COAL MINES TECHNICAL SERVICES, GAS DETECTION RELATED SERVICES FOR MINES RESCUE

Safety Tips from the WorkSafe People. Building a Safety Program for Your Organization

Additional requirements for all types of entry are described in Section Determining the Applicable Entry Method

Mine Safety Recommendations

NZQA unit standard version 3 Page 1 of 8. Manage the mine ventilation system at an extractive site

Marshall Municipal Utilities CONFINED SPACE ENTRY Effective January 1, 2011

NZQA unit standard New US 1Non-coal of 7145 version 1 Page 1 of 5

Dräger MRC 5000 Refuge Chambers

CONFINED SPACE PROGRAM

Optimization of a Proven Technology

GUIDELINES FOR CONDUCTING HYDROGENATION REACTIONS

water purification cylinders & accessories

TECHNICAL DATASHEET ELSA MUSTER ESCAPE BREATHING APPARATUS DESCRIPTION APPLICATIONS

Dräger PAS AirPack 1 Compressed Air Breathing Apparatus

PSSI 36 General Confined Spaces, Tunnels, Culverts and Similar Spaces

Personal Protective Equipment 29 CFR 1926

Compressor Seal Replacement and Upgrades SERVICES

Contents. 1. General information BROEN BALLOMAX Steel Ball Valves Approvals Quality Management...2

Respiratory Protection

Hampstead Hill School Health and Safety Policy: Confined Spaces

MSA AUER SSR 90 [K60]

Memo. Shelley Cohen. From: Bill Dickson CC: Date: February 5, 2015 Re: Editorial Oil & Gas News

Niltox Breathing Air Purifier Range

HANDS-FREE RC ROD HANDLER. Technical Datasheet. Copyright 2012 Boart Longyear. All rights reserved.

CAUTION Hard copies of this document may not be the current version. Refer to the "I Am The Key" verify the current version,

Orchard Farm Fire Protection District Standard Operating Procedure

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Organic Vapor/P95, Disposable

Series IRV1000/2000/3000

APPLICATION & LIMITATIONS:

Operate Breathing Apparatus

4-7 kw/ hp. Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward

CONFINED SPACE PROGRAM

Laboratory Safety Training. Environmental Health and Safety

CAST IRON SAFETY VALVE TYPE 6301

Transcription:

Coal Mine Change-Over-Stationg (COS) Designed to provide a safe and secure area for miners to rest and change breathing apparatus as they step their way out of a hazardous and/or toxic environment. MineARC CoalSAFE Change-Over-Station (COS) The world's leading manufacturer of emergency life-saving refuge www.minearc.com 1

Companyp y Profile MineARC Systems is the global leader in the manufacture and supply of emergency refuge chambers used in the underground mining, tunnelling, and chemical processing industries. MineARC has offices and manufacturing facilities in Australia, South Africa, Chile, China, the United Kingdom and the United States, as well as a strong distribution network worldwide. MineARC manufactures and supplies refuge chambers to operations in over 40 countries world-wide. All MineARC refuge chambers comply with the highest international industry regulations and guidelines. With over 15 years experience in the industry, our dedication to ongoing research and development has kept us at the forefront of safe refuge technology. MineARC is the only refuge chamber manufacturer in the world with an ISO: 9001 quality rating. www.minearc.com MineARC refuge chambers have been successfully used around the world in multiple mine and tunnelling emergencies to save lives. WV Office of Miners' Health, Safety & Training Approval Built to MSHA 30 CFR Parts 7 and 75 IHST, Inc. Independent Human Testing WJE, Inc. Independent Blast and Structural Analysis MineARC Team Based Risk Assessment Testing Bureau Veritas ISO 9001:2008 Quality Management Systems MA Chinese MA Centre Certified 2 MineARC Systems

MineARC Change-Over-Station The MineARC Change-Over-Station (COS) is designed to aid miners as they exit the mine; providing a safe and secure staging-post stocked with breathing apparatus, such as self-contained-self-rescuers (SCSR s). Inside a MineARC COS, breathing apparatus can be changed over in safety, while personnel compose themselves and continue to plan their escape. Each COS features custom-designed storage to accommodate specific makes/models of breathing apparatus. Standard Dimensions Model Length Height Width Occupancy Seated Compressed *1 Rotating *2 Air cylinders Total Occupancy COS 8 3.2m 2.4m 2.3m 8 6 = 51600L 20 people for 20 mins COS 12 4.4m 2.4m 2.3m 12 8 = 68600L 30 people for 15 mins COS 16 5.5m 2.4m 2.3m 16 10 = 86000L 40 people for 15 mins COS 20 6.9m 2.4m 2.3m 20 12 = 163200L 50 people for 15 mins COS 26 9.2m 2.4m 2.3m 26 15 = 129000L 60 people for 16 mins COS 30 10.4m 2.4m 2.3m 30 17 = 120400L 70 people for 15 mins * 1 Note: More cylinders will Increase duration of rotating occupancy * 2 Note: Fewer occupants will increase duration 3

Construction MineARC s Change-Out-Station (COS) has been designed and engineered to facilitate self-escape from the mine in the event of an emergency. The COS is constructed from 5mm steel plate with internal support wraps and surround package as standard. The COS s floor plate is constructed from 6mm (1/4 ) steel plate with tubular skids. Push points and towing / lifting eyes are provided top and bottom at front and rear. Main Chamber The COS s internal main chamber area features durable high grade material seating on both sides, with ample under-seat and above head storage. Inside the COS is a dedicated storage area for housing SCSR's. 4 MineARC Systems

Features Summary Entry / Exit Air Curtain The walk-through layout of the COS features a pneumatic flushing air curtain system fitted to both the entry and exit doors. On entry both air curtains activate simultaneously, releasing 400L of compressed air per minute, for two whole minutes. On activation, 200L per minute passes directly over the opening door, creating a barrier to help prevent toxins and smoke entering the main chamber. Once the door is closed, the remaining compressed air creates a positive pressure environment inside the main chamber, forcing any further toxins and/or smoke out of the main chamber via the one way check valves. Positive Pressure Respirable Atmosphere After entering the main chamber area, miners may require a rest break or some time to wait for others and re-group before donning there SCSR s and moving onto the next COS. In this instance, miners should activate the positive pressure system inside the main chamber. The system comprises a simple compressed air regulator dial, which should be adjusted to reflect chamber occupancy. The regulator releases 85L of compressed air, per person, per minute, creating positive internal pressure inside the main chamber and clearing it of all toxins, as well as carbon monoxide (CO) and carbon dioxide (CO 2 ). Positive internal pressure ensures occupants are provided with a clean respirable environment in which to change over their SCSR's. Service and Maintenance The COS is easy to inspect and maintain, requiring minimal preventative maintenance. MineARC Systems has a dedicated service team with the capacity to undertake all servicing requirements as well as accredited training programs for site personnel to perform their own servicing. Secure Cylinder Storage High pressure compressed air cylinders provide air supply to the main chamber area, as well as powering the entry / exit air curtain systems. All cylinders are stored within the COS s, robust blast rated steel structure. 5

Features Summary Intrinsically Safe Design Breathable Air Supply CO 2 and CO Scrubbing (Optional) Flushing Air Curtains SCSR Storage 5mm Steel Plate Construction Standard Features Intrinsically Safe Design Pneumatic Flushing Entry / Exit Air Curtain Breathable Air Supply 5mm Steel Plate Construction Ample SCSR Storage (Self Contained Self Rescuer) Explosion Proof Ballistic Glass Viewing Portal Vortex Cooling Communication Ports Ergonomicly Designed Seating Forklift Slots and Towing Eyes Non-Slip Flooring Cyalume Light Sticks Secure Internal Storage Area Reflective Signage Optional Features Compressed Mine Air Fliter Pack CABA Quick-Fill Station (Compressed Air Breathing Apparatus) MARCis Carbon Dioxide & Carbon Monoxide Scrubbing Intrinsically Safe Air Conditioning Emergency Escape Hatch Fire Proof Structure Intrinsically Safe Flashlight Fire Extinguisher First-Aid Kit Manual Gas Monitoring Device Intrinsically Safe Long-Life Strobe 6 MineARC Systems

Optionalp Features The MARCis Through innovative design, the COS comes with the option of a powerless carbon dioxide / carbon monoxide scrubber, as well as a powerless air conditioning system - The MARCis (MineARC Air Refuge Chamber intrinsically safe). Carbon Dioxide & Carbon Monoxide Scrubbing MineARC s patented carbon dioxide (CO 2 ) and carbon monoxide (CO) scrubbing system requires no electrical power to operate. The active chemical scrubbing system is designed to clean the air of these harmful gases and toxins that build up over time within a sealed, occupied environment. MineARC developed the technology to provide the occupants with ease of use and extended time periods between chemical change outs. Intrinsically Safe Air-Conditioning Independent testing has verified that a cooling system is essential for combating the potentially fatal effects of long term metabolic heat buildup inside an occupied refuge. To maintain the internal atmosphere of the COS, the MARCis incorporates a non electrical air conditioning system that both cools and dehumidifies the COS's main chamber. MARCISORB CO 2 and CO chemical cartridges provide proven chemical scrubbing capabilities and are easy to handle. Sealed in a barrier film bag, the cartridges will store efficiently for long periods of time without degradation or requiring any maintenance.

MineARC Systems HEAD OFFICE MineARC AUSTRALIA 274 Welshpool Road, Perth, Australia 6106 ph: +61 (8) 9333 4966 fax: +61 (8) 9333 4900 email: info@minearc.com.au MineARC NORTH AMERICA 4850 W. Ledbetter Drive Dallas, Texas, 75236 USA ph: +1 (214) 337 5100 fax: +1 (214) 337 5103 email: info@minearc.com MineARC SOUTH AMERICA Avda. El Salto N 4001 oficina 142 A, Piso 14 Comuna de Huechuraba, Santiago, Chile ph: +56 2 2964 4290 fax: +56 2 2964 4291 email: info@minearc.com MineARC AFRICA Stand 205, Flaming Rock Rd, Northlands Business Park, 29 Newmarket Street, North Riding, Johannesburg, South Africa ph: +27 (0) 11 796 5162 fax: +27 (0) 86 504 1750 email: info@minearc.co.za MineARC CHINA Room 209, Tower C, Fangheng International Center, NO. 6 Wangjing Futong Street, Chaoyang District, Beijing, PR China 100102 ph: +86 10 8472 6488 / 8472 6508 fax: +86 10 8478 5769 email: info@minearc.com.au MineARC EUROPE 510 9 Buckle Street, London, E1 8LL ph: +44 7522 618 516 email: info@minearc.com.au The world's leading manufacturer of emergency life-saving refuge The world's leading manufacturer of emergency life-saving refuge www.minearc.com