ERZ 2000-NG Flow Computer

Similar documents
Ultrasonic Flowmeter USZ 08

Electronic Volume Correctors

Product Information. Three in One: Gas Meter Tariff Device Volume Corrector. Ultrasonic Gas Meter ECOSONIC X12

Online data sheet FLOWSIC30 GAS FLOW METERS

Bernhard Thomas September EnCal 3000 prochain Energy in Gas with ROI

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Flowatch Multiphase Flow Meter

Online data sheet FLOWSIC500 GAS FLOW METERS

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

LT GasAnalyzer. LT GasAnalyzer Page 1 of 6

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

SonoMeter 30 Energy Meters

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring.

General Specifications

ONSITE PROVING OF GAS METERS. Daniel J. Rudroff WFMS Inc West Bellfort Sugar Land, Texas. Introduction

General Specifications

Code Basic module and level control complete with optionals code

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Product information. Ultrasonic Gas Meter. Custody Transfer Measurement in Natural Gas Distribution

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

Pneumatic high-pressure controller Model CPC7000

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

2007 Gas-Lift Workshop

HumiSys HF High Flow RH Generator

Pneumatic high-pressure controller Model CPC7000

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

Micro Motion 3098 Gas Specific Gravity Meter

General Specifications

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

Pro-V Multivariable Flowmeter

Model 601CV. Mass Flow Controller. Product Features:

LT GasAnalyzer beyond standards

Schedule of Requirements THERMODYNAMICS LABORATORY- CHEMICAL ENGINEERING DEPARTMENT

ABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter

Diagnostics in the instrumentation More than just equipment monitoring

TH-1800-T TRX-700-CNG Converter

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

Connect with Confidence NO POWER NO PROBLEM

Automatic Isokinetic Sampler. ST5 Evo

THERMAL MASS FLOW MEASUREMENT FOR GASES

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

ONSITE PROVING OF GAS TURBINE METERS Daniel J. Rudroff Invensys Metering Systems

Vortex Meters for Liquids, Gas, and Steam

628 Differential Pressure Decay Leak Tester

Vehicle- or rack-mounted liquefied gas meters, pump supplied

General Specifications

Panther 5 Acute Care Ventilator

deltaflowc deltaflowc Venturi or Probe

RS D RSF D with direct drive

SENSAPHONE APPLICATION NOTE. Functions: C Programming, Pump Control, Data Logging

Electronic gas volume corrector model DGVC-04

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

WF STEUERUNGSTECHNIK GMBH. INFORMATION and TECNICAL DESCRIPTION

BUBBLER CONTROL SYSTEM

Gas Measurement Fundamentals Certification. Curriculum

Ingersoll Rand. X-Series System Automation

Digital Mass Flow Meters and Controllers for Gases

THE NEW SP SERIES MAXIMUM CAPACITY MINIMUM FOOTPRINT

PHOENIX L300i Best-in-class Helium Leak Detectors

Remote. Measurement Assurance. Why CEESmaRT? significantly in measurement

analytical bulk flow distance FLOW level pressure temperature industrial communication

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Variable Area Flow Meters

Specifications and information are subject to change without notice. Up-to-date address information is available on our website.

780S Ultra High Purity Series

Model EXAxt AV550G. Averaging Oxygen Analyzer

FAS-W. Features. Applications. Automatic condensation hygrometer

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司

Improve Process Reliability

Visualize Nitrogen Gas Consumption

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

RS 2-75 D 109 D RSF 87 D 127 D with direct drive

Energy Management solutions for compressed air and industrial gases. vpinstruments.com

Traysealer T 100. Tray packaging in the smallest space

Ron Gibson, Senior Engineer Gary McCargar, Senior Engineer ONEOK Partners

COMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid

Electronic Turbine Meter TERZ 94

IT STARTS AT THE SOURCE - RE-CALIBRATING YOUR PLANT METERS

Built-in Purge Control Functions

BUYER S GUIDE AQUAlogger 530WTD

Injection Controller Program User Manual (for FloBoss 107 and ROC800-Series)

TRZ 03-K Volumeter. Proven Technology. Superior Performance. TRZ 03-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering.

THE NEW SP SERIES MAXIMUM CAPACITY MINIMUM FOOTPRINT

Vortex flowmeters. Product family introduction Principle of operation Product review Applications Key product features

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

deltaflowc deltaflowc Gas Massflowmeter Venturi- and Probe Type

Multiphase MixMeter. MixMeter specification. System Specification. Introduction

Chapter 22 Testing Protocols

Premium Series: Pressure, Differential Pressure and Level Transmitters. PASCAL Ci4. Chemical industry Mechanical engineering Process industry

How to specify a product. Process Sensors and Mechanical Instruments

CONTROL and INSTRUMENTATION

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

Integral type Differential pressure flowmeter VNT Series

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

AUTOMATIC HOSE TEST UNIT, TYPE SPU

UNDERSTANDING, ACCELERATED

AGW SYSTEMS. Blue Clock W38X

COMPRESSOR PACK SUCTION CONTROLLER TYPE: LP41x

Transcription:

ERZ 2000-NG Flow Computer With decades of natural gas measurement experience, RMG has developed the ERZ 2000-NG an approved and best-in-class gas flow measurement solution for all areas of gas volume conversion. Competitively priced and offering a low total cost-of-ownership, it meets a wide range of application requirements throughout the natural gas industry. This is the reliable, precision gas measurement system you need. Proven Performance. Robust Functionality.

Rely on RMG Over 150 years of combined experience in the natural gas industry Worldwide solution leader in measurement and analysis technology Products for natural gas transportation, storage, distribution and consumption Local support with global expertise Single source provider with a wide portfolio The natural gas business is demanding. Service organizations need a proven solution to measure gas flow and correct for volume in custody transfer and secondary metering applications.

Reliability Matters The RMG ERZ 2000-NG Series flow computer and gas volume corrector meets the challenges of today s fast growing natural gas industry. Featuring a new graphical touchscreen user interface, it is a versatile instrument designed to meter gas flow, correct measured volume, calculate energy consumption and display all data via standardized protocols. Simple plug-in operation also reduces the number of on-site visits. Inherently Precise Regardless of pressure and temperature, a gas meter measures only the gas volume flowing through it in other words, the volume at measuring conditions. Since gas can be compressed, the quantity actually flowing through the meter still must be calculated from the measured volume at measurement conditions. As a measure for this quantity of gas, the volume at base conditions is used. The ERZ 2000-NG performs gas volume conversion on the basis of the equation of state for ideal gases. Since this equation alone does not meet all the requirements for high-precision gas metering, the gas volume corrector also takes into account the characteristics of the real gas by using the K co-efficient as a correction factor. Such an approach ensures utmost measurement accuracy and repeatability. Fully Integrated The ERZ 2000-NG can be incorporated into a complete solution for the gas train. The unit is easily integrated in a cabinet along with gas chromatographs, specialized flow computers, data loggers and controllers. Compatibility is Key The flow computer can be used for custody transfer and secondary metering applications in conjunction with all types of gas flowmeters, including turbine meters, vortex meters, ultrasonic gas meters and rotary displacement meters, as well as orifice plate metering. Typical applications include: Custody Transfer Compressor Stations Gas Pressure Reducing Skids Remote Station Monitoring Gas Storage City/Regional Gas Suppliers Biogas Applications 1

The ERZ 2000-NG utilizes a wide range of communication protocols to deliver data securely to SCADA, ERP or data collection systems. Meeting the Challenge Easy to Operate RMG has optimized the technique for precision, certified and standardsbased gas flow measurement and volume correction. The ERZ new-generation system provides an enhanced user experience to simplify operation and improve application results. Its intuitive Human- Machine Interface (HMI) touchscreen navigation suitable even for operators wearing gloves and using a touch pen reduces time for commissioning and maintenance. Remote maintenance software capabilities also limit the number of on-site visits. In addition, the device incorporates an optional USB port for use of an external keyboard in service and maintenance. Secure Communication The ERZ 2000-NG utilizes a wide range of communication protocols to deliver data securely to SCADA, ERP or data collection systems. It also employs a pair of Ethernet plugs (RJ45) to communicate with separate IP networks, ensuring better overall system security and support for separate networks, and eliminating the influence from remote readings. Industry Approved Backed by the proven reliability of RMG, the ERZ 2000-NG is approved as a gas volume and calorific value corrector for the custody transfer metering of natural gases. The flow computer monitors limits specified for custody transfer metering. An alarm is tripped if these limits are exceeded and separate disturbance totalizers are used for metering. All alarm messages are stored in a log, just like all parameter changes. 2

The ERZ 2000-NG base module performs neutral measurements of all inputs similar to a multimeter, but no calculations or assignments to physical units are made. Robust Functionality System Configurations The ERZ 2000-NG Series is designed as a universal instrument, which can be used for all metrological tasks in a gas metering station. The flow computer is available in a choice of system configurations, including: ERZ 2004-NG Volume Corrector Calculates gas volume at base conditions via pressure, temperature and K co-efficient (PTZ). ERZ 2104-NG Calorific Value Corrector (PTZ) Calculates gas volume at base conditions via pressure, temperature and K co-efficient and energy content with gas quality. The ERZ 2000-NG base module performs neutral measurements of all inputs similar to a multimeter, but no calculations or assignments to physical units are made. Therefore, the unit only deals with analog values, frequencies and meter contents without knowing the meaning of individual values. The measured values are assigned to the appropriate physical quantities and converted into usable data. The base module also provides all outputs and data interfaces, as well as three spare slots for hardware extensions and future requirements. The ERZ 2000-NG employs a powerful microprocessor system based on an ARM CPU with an associated program memory (flash memory), random access memory and data memory. The random access memory contains the variables, fields and buffers required for running the system software and the changeable device parameters of all functional modules. The parameters are protected by means of a checksum, which is automatically verified with each new start of the system. Parameters relevant for custody transfer metering are protected by a sealable switch, the others by a code number. The program memory contains the operating program for the device. A CRC checksum is calculated via the source code and deposited as a reference value. ERZ 2014/2114-NG Differential Pressure Computer Evaluation computer and gas volume corrector intended for orifice plate metering. 3

Intuitive touchscreen user interface simplifies system configuration and operation, displaying key information in well structured tabs. Features and Functions Test Functions Functions such as On-the-fly Calibration, Freeze or Functional Test enable manual or automatic test totalizers to be started or stopped, as well as means to be calculated or measured values to be frozen. Touchscreen HMI Intuitive touchscreen user interface simplifies system commissioning, maintenance and operation, displaying key information in well structured tabs. For example, measurement data and totalizers are visible at a glance as defined by approval authorities. The operator can also view tools for commissioning, maintenance and calibration. Additionally, the HMI presents tables of all detailed measurement data, parameters, archives; events and alarm log information; and trend graphs. Remote Maintenance With a PC in the control center, the ERZ 2000-NG can be easily maintained remotely via a Web browser. Original Totalizer Readings In the case of gas meters with encoders, it is possible to digitally transmit their readings to the ERZ 2000-NG so the original readings are available in the corrector. Digital Inputs for Measured Values As an alternative to analog transmission of measured values from pressure transmitters and resistance thermometers, the values can also be transmitted digitally in conformity with the HART protocol. Calculation of Compressibility Factor K The ERZ 2000-NG gas volume corrector calculates the K co-efficient of natural gases in accordance with most calculation methods. Bus Interface The device has standard interfaces for Modbus (RTU/ASCII), DSfG and RMGbus, and Modbus-IP. Data Logging The ERZ 2000-NG includes a data logger providing conventional data logging and the DSfG archive (i.e., a data memory recording data generated in the corrector and transmitted via the DSfG interface). Error Curve Linearization During high-pressure testing of a gas meter, its error curve (which depends on the flow rate) is determined. This error curve can be simulated in the ERZ 2000-NG gas volume corrector as interpolation points, or as a polynomial applied over the flow rate or the Reynolds Number. As such, the error of measurement can be eliminated. Language Selection The flow computer software is multilingual. 4

Technical Specification Accessories 19 sub-rack Thermowells for resistance thermometers Thermal insulation for resistance thermometers Three-way check valve for pressure transmitters Stand for accommodating pressure transmitter and three-way check valve Model Type Housing Dimensions Metrological approval Hazardous area Ambient conditions Power supply Power input Control panel Display Communication Inputs DIs Temperature Analog Encoder Volume Outputs Pulse Alarms Analog DOs Data interfaces Communications protocols Compressibility Memory General platform Hardware ERZ 2000-NG 19 rack, general purpose W x H x D = 213 x 128.4 x 310 mm (42 depth units / 3 height units) PTB, MID No -20 C to +55 C 24 V/DC, 115/230 V/AC Max. 24 W Touchscreen LCD-TFT 7x 2x 8x 1x 2x/4x 4x 2x 4x 8x 5x serial interfaces / 2x TCP/IP Modbus (RTU, ASCII), Modbus TCP, DSfG, RMGBus, DZU, HART Gerg 88S, AGA 8-92DC, AGA-NX-19, AGANX-19 mod, Beattie-Bridgeman, van der Waals, AGA8 Gross Meth 1+2, AGA8 (1985) 4GB standard (optional memory extension) FC with USZ controller + Storage GC module, USM module Embedded PC, ARM 9 Controller 5

Key features Intuitive HMI for a new experience in navigating through the flow computer for commissioning, maintenance, operation and data reading Calculation of the theoretical Velocity of Sound for online comparison with measured VOS from USM In connection with turbine meter, Vortex meter, Ultrasonic meter, Rotary displacemeter and Orifice plate PGC communication via Modbus or DSfG CO 2 emission calculator Four-set of totalizers for Vm, Vb, energy, mass flow and CO 2 (disturbed and undisturbed) On-line documentation in the flow computer Internal log book of events and parameter changes Hardware always the same, software defines the new model No special operating software necessary, only browser software is required For More Information To learn more about products and solutions from RMG, visit www.rmg.com or contact your account manager. RMG Messtechnik GmbH Otto-Hahn-Strasse 5 35510 Butzbach, Germany Tel: +49 (0)6033 897-0 Fax: +49 (0)6033 897-130 RMG-18-08-ENG August 2018 2018 RMG Messtechnik GmbH