Device Description. Operating Information. CP Q (eq. 1) GT. Technical Bulletin TB-0607-CFP Hawkeye Industries Critical Flow Prover

Similar documents
S.A. Klein and G.F. Nellis Cambridge University Press, 2011

Applied Fluid Mechanics

Methods of Rating Flow

Type R622 Pressure Reducing Regulator

Comments on Homework. Class 4 - Pressure. Atmospheric Pressure. Gauge vs. Absolute Pressure. 2. Gauge vs. Absolute Pressure. 1.

SIZING AND CAPACITIES OF GAS PIPING

TUTORIAL. NPSHA for those who hate that stuffy word. by Jacques Chaurette p. eng. copyright 2006

SIZING AND CAPACITIES OF GAS PIPING

Gas Physics Pressure and Flow Topics Covered:

SIZING AND CAPACITIES OF GAS PIPING Reserved

Pressure Control. where: p is the pressure F is the normal component of the force A is the area

Comments on Homework. Quiz. Class 3 - Pressure. Atmospheric Pressure. 2. Gauge vs. Absolute Pressure. 1. Definitions. Temperature conversion

The Discussion of this exercise covers the following points:

Quick Reference Technical Data

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

Tutorial. BOSfluids. Relief valve

PRO-50 Instrument Supply Regulator

The Application of Temperature and/or Pressure Correction Factors in Gas Measurement

Technical Committee on LP-Gas at Utility Gas Plants

Application Notes for Valve Sizing Sizing valves for steam service with the aid of sizing charts

Unit 2 Kinetic Theory, Heat, and Thermodynamics: 2.A.1 Problems Temperature and Heat Sections of your book.

Application Worksheet

****** * EX * ****** DWN W.W.POWELL CALCULATION OF FLOW LOSSES IN INLET CHK D.PAPA AND DISCHARGE HEADERS ASSOCIATED WITH

Impact of imperfect sealing on the flow measurement of natural gas by orifice plates

Chapter 1: Basic Concepts of Pneumatics

Lab 3 Introduction to Quantitative Analysis: Pumps and Measurements of Flow

The most common terms rating air flow capacity are ICFM, FAD, ANR, SCFM or nl/min

SIZING AND CAPACITIES OF GAS PIPING

T208VR Series Tank Blanketing Vacuum Regulator

COMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid

Y692VB Series Vacuum Breaker

CHAPTER 3 : AIR COMPRESSOR

Rupture Disc Sizing for Micro Motion Coriolis Sensors

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C

Micro Motion Pressure Drop Testing

SIZING AND CAPACITIES OF GAS PIPING

TWO PHASE FLOW METER UTILIZING A SLOTTED PLATE. Acadiana Flow Measurement Society

INTRODUCTION TO REGULATOR AND RELIEF VALVE SIZING. Introduction

OVERVIEW. Flow Coefficient C v. Operating Conditions. Specific Gravity

Test Report # Rev 0. Adiabatic Compression With Constant Bleed Valve

AIAA Brush Seal Performance Evaluation. P. F. Crudgington Cross Manufacturing Co. Ltd. Devizes, ENGLAND

The Discussion of this exercise covers the following points: Pumps Basic operation of a liquid pump Types of liquid pumps The centrifugal pump.

PROPERTIES OF R-134A (1,1,1,2-TETRAFLUOROETHANE)

For Multi-Parameter Meters see mvx

3 1 PRESSURE. This is illustrated in Fig. 3 3.

Chapter 13 Gases, Vapors, Liquids, and Solids

EN00 Pre-Instructional Survey

This portion of the piping tutorial covers control valve sizing, control valves, and the use of nodes.

Name Chemistry Pre-AP

Restriction Orifice. Single or Multi Stage Orifice to. Reduce Pressure or. Limit the Flow Rate

CALCULATING THE SPEED OF SOUND IN NATURAL GAS USING AGA REPORT NO Walnut Lake Rd th Street Houston TX Garner, IA 50438

SIZING THE EXTROL DIAPHRAGM-TYPE HYDRO-PNEUMATIC TANK

2 are both ways of saying a ratio of 2 to 5

Exp. 5 Ideal gas law. Introduction

TOPIC: KNOWLEDGE: K1.01 [2.5/2.7] An atmospheric pressure of 15.0 psia is equivalent to... A psig. B psig. C psig.

Noth American 7347 High Pressure Gas Regulators

NORDCALC Introduction... 2 Registration... 2 Flow Calculations tab Torque Calculation & Actuator Mounting Data tab... 21

THE WAY THE VENTURI AND ORIFICES WORK

STANDARD FOR CONTROL VALVE SEAT LEAKAGE

Quiz #1 Thermodynamics Spring, 2018 Closed Book, Open Appendices, Closed Notes, CLOSED CALCULATORS

Example: Calculate the density of methane at 50 psig and 32 ⁰F. H.W. In previous example calculate the density of methane in gm/m 3.

Paper 2.2. Operation of Ultrasonic Flow Meters at Conditions Different Than Their Calibration

Ideal gas law. Introduction

No E. General Information. Averaging Pitot Tube Flow Sensor HITROL CO., LTD.

For Multi-Parameter Meters see mvx

Type Cronos Pressure Reducing Regulator

B34 Series Regulator Commercial and Industrial Regulator

Chapter 14-Gases. Dr. Walker

VB-7213 Series. Application. Features. Applicable Literature. 1/2" to 2" Screwed NPT Stem Up Open, Two-Way Valves General Instructions

GLOSSARY OF TERMS. Adiabatic Compression Compression process when all heat of compression is retained in the gas being compressed.

ANDERSON GREENWOOD. Provides reliable overpressure protection in a cost effective package. Flow Control

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

COMPUTATIONAL FLOW MODEL OF WESTFALL'S LEADING TAB FLOW CONDITIONER AGM-09-R-08 Rev. B. By Kimbal A. Hall, PE

VB-7263 Series. Application. Features. Applicable Literature

1805 Series Relief Valves

VB-7211 Series. Application. Features. Applicable Literature. 1/2" to 1-1/4" Union End NPT Stem Up Open, Two-Way Valves General Instructions

Reservoir Fluid Fundamentals COPYRIGHT. Dry Gas Fluid Basic Workflow Exercise Review

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

Pilot Operated Safety Relief Valves For Liquified Gas Carriers

Engineering Information. Flow Data. Flow Data. Importance of Valve Sizing. Estimating Cv or Orifice Size:

FUNDAMENTALS OF PRESSURE REGULATORS ROBERT BENNETT MANAGER OF TRAINING ELSTER AMERICAN METER

VB-7273 Series. Application. Features. Applicable Literature

Exercise 4-2. Centrifugal Pumps EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Pumps

Part 6: Critical flow orifices

General. Rugged, Reliable with Value-added Features. Pipe Sizes. Temperature Limits. Spring Ranges. Buried Service. Increased Outlet Pipe Sizes

1800CPB2 Service Regulators Maximum Inlet Pressure 125 PSIG

North American Orifice Metering System

Cover Page for Lab Report Group Portion. Compressible Flow in a Converging-Diverging Nozzle

Appendix A Frequently Asked Questions

The Hoffman Specialty Series 2000 consists of main

Process Dynamics, Operations, and Control Lecture Notes - 20

VB-7323 Series. Application. Features. Applicable Literature. 1/2 to 2 Screwed NPT Three-Way Diverting Valves General Instructions

Chapter 10 Gases. Characteristics of Gases. Pressure. The Gas Laws. The Ideal-Gas Equation. Applications of the Ideal-Gas Equation

Chapter 5. Pressure. Atmospheric Pressure. Gases. Force Pressure = Area

299H Series Pressure Reducing Regulators

VBS-9263 Series. Application. Features. Applicable Literature

Full Range Pressure Compensating Variable Flow Control

Figure Vapor-liquid equilibrium for a binary mixture. The dashed lines show the equilibrium compositions.

Unit A-2: List of Subjects

Chem 110 General Principles of Chemistry

Transcription:

A compressible fluid traveling at subsonic velocity through a duct of constant cross section will increase velocity when passing through a region of reduced cross-sectional area (in this case, an orifice) to satisfy mass flow continuity. To satisfy conservation of energy, the fluid pressure at the obstruction decreases (i.e. Venturi effect). Maximum velocity at the obstruction is limited by the rate at which pressure waves can propagate through the fluid ( the speed of sound ), and the flow will not exceed this velocity at the obstruction. Known as choked, or critical flow, the orifice velocity remains constant over a wide range of downstream pressure and temperature conditions. Since volumetric flow is proportional velocity, the volume flow rate of a choked flow can be determined based solely on upstream absolute pressure and temperature. Critical flow will occur as the ratio of the obstruction flow area to the duct flow area approaches zero, and the ratio of upstream to downstream pressure for air, assumed to be an ideal gas, is.528. That is, the downstream pressure must be.528 times the upstream pressure (or less) in order to have critical flow at the obstruction. For example, to have critical flow with an upstream pressure of MPa, the downstream pressure must be 5.28 MPa or less. Empirically, natural gas exhibits critical flow behavior with straight-edge orifice diameters less then 6% of the pipe diameter, and ratio of absolute downstream to absolute upstream pressure between.56 and.58. For example, a subsonic natural gas flow in a 5 mm pipe at MPa will be critical through a 3 mm (or smaller) orifice, and downstream pressure of 5.6 MPa or less. The critical flow prover device ensures choked flow over a wide range of downstream pressures, allowing the use of critical flow property relationships to determine flow rate. By using critical flow properties, variability as a result of fluctuating downstream conditions is negated, Hawkeye Industries Critical Flow Prover The critical flow prover (CFP) device provides a means to determine gas flow rate, Q, using principles of adiabatic, frictionless compressible flow in the critical, or choked, condition. Principles of Operation allowing flow rates to be computed based solely on upstream conditions. Device Description The Hawkeye Industries Critical Flow Prover consists of a tubular section, approximately 6 pipe diameters long, with a smooth inside diameter and standard 2 NPT connection on the upstream end. The opposite end features a recess, with an o-ring face-seal, for a /4 in. thick orifice plate, held in place by a knurled retention cap. Approximately one pipe diameter upstream of the orifice plate are a NPT and /4 NPT pressure taps, suitable for gauge mounting and a thermowell. Operating Information The flow rate through the CFP is determined using the following equation: CP Q (eq. ) GT Where: Q = Flow Rate ( 3 ft 3 / 24 hr (aka Mcfh) or 3 m 3 / d) C = Orifice Coefficient (empirically derived, see tables a and b) P = Absolute Upstream Pressure (psi or MPa) G = Specific Gravity of Gas (air =.) T = Absolute Upstream Temperature ( R or K) Note: Equation assumes a perfect gas, and does not account for deviations from Boyle s Law behavior. Units: When determining flow rate in imperial units ([Mcfh], or [ 3 ft 3 /24hr]) use the following units in Equation : C: From Table a. 2 P: pounds per square inch [psi] G: unitless T: Rankine [ R] Eq. 9.32, White, F.M., (999). Fluid Mechanics. New York: WCB McGraw Hill. 2 Form -, Page 3-2, Chandler Engineering Company (959). Instructions: Critical Flow Prover Bureau of Mines Type for Back Pressure Tests on Natural Gas Wells.

Likewise, to determine flow rate in metric, or SI units ([ 3 m 3 /d]) use the following units in equation : C: From Table b. P: Megapascals [MPa] G: unitless T: Kelvin [K] Absolute Temperature: Thermodynamic calculations require use of absolute temperature in computations. In imperial units, absolute temperature is measure in Rankine ( R), calculated using the following formula: [ R ] [ F] 459.67 (eq. 2) Example: 6 F = 59.67 R Similarly in SI, absolute temperature is measured in Kelvin (K) and is calculated using the following formula: [ K ] [ C] 273.5 (eq. 3) Example: 7 C = 29.5 K Table Empirically Derived Orifice Coefficient * IMPERIAL AND METRIC (SI) UNITS * For 2 NPS [6.3 mm] Critical Flow Prover (2. in. [5.8 mm] bore) Orifice Diameter Coefficient, C Coefficient, C Variance (in.) (mm) (imperial) (metric) (%) /6.6.524 4.666 3.6 3/32 2.4 3.355.27.4 /8 3.2 6.3 9.29 2.25 3/6 4.8 4.47 44.3 3.88 7/32 5.6 9.97 6.4 3.82 /4 6.4 25.86 79.7.88 7.9 39.77 2.8 2.3 9.5 56.58 73.2 2.74. 8.9 248.3 2.33 2.7.8 3.7 2.29 5.9 54 47.5.56 9. 224.9 688.5.3 22.2 39.3 946.9 2.3 25.4 46.7 245 2.9 /8 28.6 52.8 594.26 /4 3.8 657.5 23 3.6 34.9 87.8 2473 2.5 38. 2 368 6.32 Tables provides orifice coefficients for imperial units and metric (SI) units. The coefficients were derived from equation, using a known flow rate, Q, at a temperature of 6 F [59.67 R] and downstream pressure of 4.4 psia. Graphical Representation: The flow rate, in 3 ft 3 /24hr (Mcfh), has been calculated at atmospheric pressure and 6 F [59.67 R], and ploted on charts A through B4, with a line for each orifice size (listed on the chart margins). Chart series A is scaled to provide legible values for orifice diameters /4 in. and under, while the series B charts show full-scale flow values. Similarly, the flow rates, in 3 m 3 /d at 99.3 kpa and 6 C [289.5 K] have been calculated, and ploted on charts C through D4, with a line for each orifice size (listed on the chart margins). Chart series C is scaled to provide legible values for orifice diameters /4 in. and under, while the series D charts show full-scale flow values. These charts are for informational purposes only. Use of equation is required for accurate flow rates from a particular application. Flow Charts Scaled to /4 in. Orifice Plate Full Flow (Imperial Units): Table A: Flow Rate vs. Upstream Pressure ( psig), Table A2: Flow Rate vs. Upstream Pressure (5 psig), Table A3: Flow Rate vs. Upstream Pressure ( psig) Table A4: Flow Rate vs. Upstream Pressure (3 psig) Full Scale Flow (Imperial Units): Table B: Flow Rate vs. Upstream Pressure ( psig) Table B2: Flow Rate vs. Upstream Pressure (5 psig) Table B3: Flow Rate vs. Upstream Pressure ( psig) Table B4: Flow Rate vs. Upstream Pressure (3 psig) Scaled to /4 in. Orifice Plate Full Flow (Metric Units): Table C: Flow Rate vs. Upstream Pressure ( MPa g) Table C2: Flow Rate vs. Upstream Pressure (5 MPa g) Table C3: Flow Rate vs. Upstream Pressure ( MPa g) Table C4: Flow Rate vs. Upstream Pressure (2 MPa g) Full Scale Flow (Metric Units): Table D: Flow Rate vs. Upstream Pressure ( MPa g) Table D2: Flow Rate vs. Upstream Pressure (5 MPa g) Table D3: Flow Rate vs. Upstream Pressure ( MPa g) Table D4: Flow Rate vs. Upstream Pressure (2 MPa g) Schematic Critical Flow Prover, DWG# CFP-2-GD 2

Chart A: Flow Rate vs. Upstream Pressure (Imperial Units) psi Upstream Pressure, All Critical Orifices 5 4 Volumes at 4.4 psia, 6 F /4 3 2 7/32 Flow Rate, Q ( 3 ft 3 /24hr) 9 8 7 6 NON-CRITICAL 3/6 5 4 /8 3 2 3/32 /6 2 25 3 35 4 45 5 55 6 65 7 75 8 85 9 95 Upstream Gauge Pressure, P (psig)

Chart A2: Flow Rate vs. Upstream Pressure (Imperial Units) 5 psi Upstream Pressure, All Critical Orifices 75 7 Volumes at 4.4 psia, 6 F /4 65 6 55 7/32 5 Flow Rate, Q ( 3 ft 3 /24hr) 45 4 35 3 25 3/6 2 5 /8 3/32 5 /6 25 5 75 25 5 75 2 225 25 275 3 325 35 375 4 425 45 475 5 Upstream Gauge Pressure, P (psig)

Chart A3: Flow Rate vs. Upstream Pressure (Imperial Units) psi Upstream Pressure, All Critical Orifices 5 4 Volumes at 4.4 psia, 6 F /4 3 2 7/32 Flow Rate, Q ( 3 ft 3 /24hr) 9 8 7 6 5 3/6 4 3 /8 2 3/32 /6 5 5 2 25 3 35 4 45 5 55 6 65 7 75 8 85 9 95 Upstream Gauge Pressure, P (psig)

Chart A4: Flow Rate vs. Upstream Pressure (Imperial Units) 3 psi Upstream Pressure, All Critical Orifices 45 42 Volumes at 4.4 psia, 6 F /4 39 36 33 7/32 3 Flow Rate, Q ( 3 ft 3 /24hr) 27 24 2 8 5 3/6 2 9 /8 6 3/32 3 /6 5 3 45 6 75 9 5 2 35 5 65 8 95 2 225 24 255 27 285 3 Upstream Gauge Pressure, P (psig)

Chart B: Flow Rate vs. Upstream Pressure (Imperial Units) psi Upstream Pressure, Orifices and Larger 6 55-5 45-4 Flow Rate, Q ( 3 ft 3 /24hr) 35 3 25 4.4 psi, 6 F Orifice diameters under omitted for clarity -/4 -/8 2 5 5 95 9 85 8 75 7 65 6 55 5 45 4 35 3 25 2 5 5 Upstream Pressure, P (psi)

Chart B2: Flow Rate vs. Upstream Pressure (Imperial Units) 5 psi Upstream Pressure, Orifices and Larger 3 285-27 255 24 225-2 Flow Rate, Q ( 3 ft 3 /24hr) 95 8 65 5 35 2 5 4.4 psi, 6 F Orifice diameters under omitted for clarity -/4 -/8 9 75 6 45 3 5 5 475 45 425 4 375 35 325 3 275 25 225 2 75 5 25 75 5 25 Upstream Pressure, P (psi)

Chart B3: Flow Rate vs. Upstream Pressure (Imperial Units) psi Upstream Pressure, Orifices and Larger 6 57 54 5 48 45 42 Volumes at 4.4 psia, 6 F Orifice diameters under omitted for - - Flow Rate, Q ( 3 ft 3 /24hr) 39 36 33 3 27 24 2 8 -/4 -/8 5 2 9 6 3 5 5 2 25 3 35 4 45 5 55 6 65 7 75 8 85 9 95 Upstream Gauge Pressure, P (psig)

Chart B4: Flow Rate vs. Upstream Pressure (Imperial Units) 3 psi Upstream Pressure, Orifices and Larger 8 7 6 Volumes at 4.4 psia, 6 F Orifice diameters under omitted for - 5 4 3-2 Flow Rate, Q ( 3 ft 3 /24hr) 9 8 7 6 5 4 -/4 -/8 3 2 5 3 45 6 75 9 5 2 35 5 65 8 95 2 225 24 255 27 285 3 Upstream Gauge Pressure, P (psig)

Chart C: Flow Rate vs. Upstream Pressure (Metric Units) MPa Upstream Pressure, All Critical Orifices 6. 5.5 Volumes at 99.3 kpa abs., 6 C /4 5. 4.5 7/32 4. Flow Rate, Q ( 3 m 3 /d) 3.5 3. 2.5 NON-CRITICAL 3/6 2..5 /8. 3/32.5 /6...5.2.25.3.35.4.45.5.55.6.65.7.75.8.85.9.95. Upstream Gauge Pressure, P (MPa)

Chart C2: Flow Rate vs. Upstream Pressure (Metric Units) 5 MPa Upstream Pressure, All Critical Orifices -/8 3. 27.5 Volumes at 99.3 kpa abs., 6 C /4 25. 22.5 7/32 2. Flow Rate, Q ( 3 m 3 /d) 7.5 5. 2.5 3/6. 7.5 /8 5. 3/32 2.5 /6..25.5.75..25.5.75 2. 2.25 2.5 2.75 3. 3.25 3.5 3.75 4. 4.25 4.5 4.75 5. Upstream Gauge Pressure, P (MPa)

Chart C3: Flow Rate vs. Upstream Pressure (Metric Units) MPa Upstream Pressure, All Critical Orifices -/8 6. 55. Volumes at 99.3 kpa abs., 6 C /4 5. 45. 7/32 4. Flow Rate, Q ( 3 m 3 /d) 35. 3. 25. 3/6 2. 5. /8. 3/32 5. /6..5..5 2. 2.5 3. 3.5 4. 4.5 5. 5.5 6. 6.5 7. 7.5 8. 8.5 9. 9.5. Upstream Gauge Pressure, P (MPa)

Chart C4: Flow Rate vs. Upstream Pressure (Metric Units) 2 MPa Upstream Pressure, All Critical Orifices -/8 2.. Volumes at 99.3 kpa abs., 6 C /4. 9. 7/32 8. Flow Rate, Q ( 3 m 3 /d) 7. 6. 5. 3/6 4. 3. /8 2. 3/32. /6.. 2. 3. 4. 5. 6. 7. 8. 9... 2. 3. 4. 5. 6. 7. 8. 9. 2. Upstream Gauge Pressure, P (MPa)

Chart D: Flow Rate vs. Upstream Pressure (Metric Units) MPa Upstream Pressure, Orifices and over 25 225 Volumes at 99.3 kpa abs., 6 C Orifice diameters under omitted for clarity - 2 75 - Flow Rate, Q ( 3 m 3 /d) 5 25 NON-CRITICAL -/4 -/8 75 5 25..5.2.25.3.35.4.45.5.55.6.65.7.75.8.85.9.95. Upstream Pressure, P (MPa)

Chart D2: Flow Rate vs. Upstream Pressure (Metric Units) 5 MPa Upstream Pressure, Orifices and over 25 25 Volumes at 99.3 kpa abs., 6 C Orifice diameters under omitted for clarity - 875 - Flow Rate, Q ( 3 m 3 /d) 75 625 5 -/4 -/8 375 25 25.25.5.75..25.5.75 2. 2.25 2.5 2.75 3. 3.25 3.5 3.75 4. 4.25 4.5 4.75 5. Upstream Pressure, P (MPa)

Chart D3: Flow Rate vs. Upstream Pressure (Metric Units) MPa Upstream Pressure, Orifices and over 25 225 Volumes at 99.3 kpa abs., 6 C Orifice diameters under omitted for clarity - 2 75 - Flow Rate, Q ( 3 m 3 /d) 5 25 -/4 -/8 75 5 25.5..5 2. 2.5 3. 3.5 4. 4.5 5. 5.5 6. 6.5 7. 7.5 8. 8.5 9. 9.5. Upstream Pressure, P (MPa)

Chart D4: Flow Rate vs. Upstream Pressure (Metric Units) 2 MPa Upstream Pressure, Orifices and over 5 45 Volumes at 99.3 kpa abs., 6 C Orifice diameters under omitted for clarity - 4 35 - Flow Rate, Q ( 3 m 3 /d) 3 25 2 -/4 -/8 5 5. 2. 3. 4. 5. 6. 7. 8. 9... 2. 3. 4. 5. 6. 7. 8. 9. 2. Upstream Pressure, P (MPa)

Informational purposes only. Calculate flow rates using equation.