Microscopy Cryogenic WORKSTATION. Performance by Design

Similar documents
RC102 & RC110 Sample in Vacuum Continuous Flow Cryogenic Workstation Cryostats

Variable Temperature Storage Dewar Mount Inserts

CRYO INDUSTRIES. Liquid Helium Research Dewars

CRYO. SuperVariTemp Magnet Inserts

Vacuum. Dry Turbo Pumping Stations. Roughing Pumps for 1 K Helium Pots and Lambda Refrigerators. Hermetically Sealed Pumps for He3 Recirculation

JANIS OPERATING INSTRUCTIONS FOR SUPERCONDUCTING MAGNET CRYOSTATS

Major Design Features

Table of Contents Want full page pictures with most important parts labeled in the beginning.

Procedure for Operating Columbia (Nevis) LHe Electron Bubble Chamber Cryostat. Version 5.1

Current Leads for Cryogenic Systems

Liquid Helium Bath Cryostat

attoliquid Liquid Research Cryostats

Cryostream 800 Series

Baffles and Traps Cryotrap

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

Series Environmental Chambers

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A.

Short Introduction to Cryo-Pumps and Refrigerators. Dr Graham Rogers Leybold UK Ltd.

SPECIFICATION FOR AN MRBR 9.4 TESLA/310MM/AS CRYO-COOLED MAGNET SYSTEM

from Thames Cryogenics Ltd Total Cryogenic Solutions Cryogenic Cluster Day 22/09/2010

Description Advanced Features Typical Applications

Storage and transfer of cryofluids

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

VACGEN. Vacuum Components. Product Overview

PURCHASE AND DELIVERY OF A HELIUM CLOSED-CYCLE OPTICAL CRYOSTAT. The present tender is only an unofficial translation provided as a courtesy.

Oxford Instruments Austin, Inc.

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Vacuum Jacketed Piping Solutions

Operating Manual ALU 7 - ALU 10 - ALU 20 - ALU 26 ALU 35 - ALU 60 - ALU 100

ALU-CD 12, ALU-CD 25, ALU-CD 35, ALU-CD

AN EXPERIMENTAL INVESTIGATION ON HELIUM LIQUEFACTION USING TWO-STAGE GIFFORD McMAHON CRYOCOOLER

An Investigative and Synoptic Review on Helium Liquefaction Using a Commercial 4 K Gifford- McMahon Cryocooler

Dilution Refrigerator manual

Vacuum Pumpdown and Venting Procedure, CRaTER Thermal Vacuum System. Dwg. No

High-performance submersible pressure transmitter For level measurement Model LH-10

Magnet and RF Cavity Test Stand Design. Tom Peterson, SLAC USPAS January, 2017

Load Responsive Multilayer Insulation Performance Testing

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

Oxford Instruments Austin, Inc.

SALT RSS-NIR MID-TERM REVIEW MAY 20 & 21, 2009 THERMAL SYSTEM DESIGN

Development of High Efficiency 4K Two-Stage Pulse Tube Cryocooler

RK-IR Sample Draw Aspirator Adapter Operator s Manual

How to specify a product. Process Sensors and Mechanical Instruments

Vacuum Systems and Cryogenics for Integrated Circuit Fabrication Technology 01

PHOENIX L300i Best-in-class Helium Leak Detectors

RK LEL Sample Draw Aspirator Adapter Operator s Manual

Judson Technologies PB 219. JTC JOULE-THOMSON CRYOSTAT COOLING SYSTEM Operating Instructions. October, 2003

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

CSA Sample Draw Aspirator Adapter Operator s Manual

Gas density monitor With integrated transmitter Model GDM-100-TI

RDK-408D2 Cold Head. Technical Manual. SHI-APD Cryogenics Inc Vultee Street Allentown, PA U.S.A. Revision A: September 2005

SECTION 12 VACUUM GRIPPERS

ACCURACY, PERFORMANCE, AND HANDLING OF OIL-FILLED DIGIQUARTZ PRESSURE INSTRUMENTATION

Procedure of Xenon Transfer

AIR DRIVEN. Gas Boosters & SYSTEMS. Accepting VISA, MasterCard and American Express

SAILTEC, INC CONGER COURT, OSHKOSH, WI USA

Heliox TM. He systems to suit all applications

Trillium US Inc. Cryo-Plex 10 Cryogenic High Vacuum Pump User s Manual Rev A / November 2015

REFRIGERATION SYSTEM COMPONENTS

INSTRUCTION MANUAL. January 23, 2003, Revision 0

Cryogenic Equipment. Accessories. Directors. Director Series Storage Vessels Specifications

Chapter 6 Leak detection

TELEDYNE PB 219. JUDSON TECHNOLOGIES A Teledyne Technologies Company TELEDYNE JUDSON TECHNOLOGIES JTC JOULE-THOMSON CRYOSTAT COOLING SYSTEM

[USING THE VITROBOT April 9, Using the Vitrobot

829S1 Series Flexflo Pilot

Chlorinator MODEL MK-I

All Molybdenum Hot Zone & Elements. All Insulators are made of High Alumina. Element style - 1/8 Molybdenum Wire.

Linkam Scientific Instruments USER GUIDE. LTS420 and LTS120. Temperature Controlled Stage

Installation and Operation Manual

Pneumatic Hand Pumps with no Gauge Connection (scissor handle) AP0V (300 psi / 20 bar)

Constant Pressure Crude Oil Container Model CPCCP

Instruction Manual Updated 7/26/2011 Ver. 2.2

Buying more than 11 gauges? Call Lesman for additional discounts.

QE-1, Rev Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

Pre-Calibrated Models

Cryogenics is the science of ultra low temperatures. Low temperatures are achieved by the liquefaction of gases.

Model MTB-ASME Vertical Bladder Tanks

1. Cryogen Tanks. N2 Fill Tutorial for Vanderbilt Magnets. Contents: CSB NMR Facility

DIVATOR THE COMPLETE DIVING SYSTEM INTERSPIRO PRODUCT CATALOG

Model MTB-ASME Vertical Bladder Tanks

Customer Responsibilities

Liquid Gas Cylinder (LGC)

Constitution Instructions

KGW - ISOTHERM. Operating Instructions. Level controlling device for liquid nitrogen LEVEL CONTROL LN2

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

Equipment and Accessories. ROMIL LiQuiSure. Designed for High Purity Containment & Dispensing PURE CHEMISTRY

SECTION 11 VACUUM GRIPPER

Oxygen Contamination

Model # HC-MIS INSTRUCTION MANUAL

Columbus Instruments

Series IRV1000/2000/3000

VACUUM & AIRLESS. Select from Kimble vacuum traps, manifolds, Schlenk tubes, adapters, and bubblers for your vacuum and airless glassware needs.

LQ Series Connectors. What is the LQ2?

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Tank Blanketing Pressure Regulators RHPS Series

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

Thanks for choosing EJAI SOLAR product

Loss of Vacuum Experiments on a Superfluid Helium Vessel

Transcription:

CRYO Microscopy Cryogenic WORKSTATION Optical cryostat for use in microscopy and spectroscopy Performance by Design RC102-CFM Microscopy Cryostat offers fast cooldown, high efficiency, excellent temperature stability and ultra low vibration levels. The sample can be set to be very close to the window. Interchangeable sample holders optimize the cryostat for different samples and different optical configurations. Very easy to operate and Performance by Design. The highly efficient detachable stainless steel flexible transfer line connects the WORKSTATION to the storage dewar. Uses either liquid helium or nitrogen. The liquid cryogen is delivered to the sample mount through the vacuum insulated transfer line. An adjustable needle valve provides flow rate control. Connect the heater on the sample mount to the temperature controller for automatic variable temperature operation. The model RC102-CFM Variable Temperature Continuous Flow Optical Microscopy Cryostat features: Large clear view windows Reflection or transmission Extra thin windows available 0.5 mm (0.020 ), 1.5 mm (0.06 ) is standard. Operating range (<4 to 325K) Use either liquid helium or nitrogen Efficient with Push or Pull operational modes Sturdy, strong stable support structure Ultra low drift and sample vibration Compact design (45 mm thick) Go THIN option (30 mm thick) THIN fits the popular Olympus BX41 NOMOVE option provides near zero movement due to thermal contraction CRYO Industries of America, Inc. 11124 South Willow St. Manchester, NH 03103 Tel: (603) 621-9957 Fax: (603) 621-9960 e-mail: cryo@cryoindustries.com

Compact - lightweight and portable, easily integrated into microscopes and spectrometers Efficient - lower cryogen consumption, economical operation and fast cooldown Flexible - operates in any orientation Optimized - adjustable close working distance to sample allows proper positioning of high power lens Reliable - no diaphragm pump required - based on our popular and proven RC102 Cryogenic Workstation Variable temperature - <4K to 325K (500K optional) Versatile - Use either liquid helium or nitrogen - push-or-pull operation The WORKSTATION The RC102-CFM is a sample in vacuum cryostat. The sample holder is located in vacuum. A flow of liquid helium or nitrogen cools the sample, which can be adjusted away from or very close to the window. For high rigidity, the sample is supported on both sides (not shown in drawings). Front and rear sample supports provides high rigidity and ultra-low vibration and drift. The WORKSTATION can be operated in any orientation. The standard system includes a six (6) foot (8 foot optional) flexible transfer line with a 48 inch (60 inch optional) storage dewar leg. The typical setup consists of the RC 102-CFM cryostat, a liquid helium (or nitrogen) storage dewar, helium gas cylinder with pressure regulator and a vacuum pump. A stainless steel flexible transfer line is supplied with the system. The transfer line leg inserts into the liquid cryogen. A small pressure is used to transfer the liquid out of the storage dewar, through the transfer line and directly to the sample mount. A flow control valve regulates the cryogen flow. Pressure inside the storage dewar can be adjusted using a helium gas cylinder. An activated charcoal cryopump built into the transfer leg will automatically pump when inserted into liquid helium or nitrogen, maintaining excellent vacuum during extended periods of operation. The transfer line quick disconnects to and from the microscopy WORKSTATION. Electrical connections to the sample are made through the o-ring sealed ports located on the instrumentation housing. A spare port is provided for future requirements. For safety, the shroud and transfer line are protected against overpressure by pressure reliefs. The evacuation valve for the transfer system is located above the valve control knob. The evacuation valve for the sample region is on the instrumentation housing. The vacuums are completely independent. Variable temperature is automated using an electronic temperature controller. A heater is attached to the heat exchanger. Simply, set the desired temperature into the temperature controller and obtain the desired temperature. Operation below 4K is achieved by reducing the flow pressure by pumping on the helium vent. Windows at 0 and 180 degrees provide optical access. Standard window material is clear fused quartz, 1.5 mm thick (0.5 mm thick option is available); suprasil and other window materials can be selected. The standard clear view aperture is 23 mm diameter (13 mm for 0.5 mm thick windows). For reflection, the total angle of acceptance is 145 C2

145 30mm degrees. For transmittance, the angle from center is 117 degrees. The adjustable holder allows the sample to be moved right up to the window. Samples can be mounted through the radiation shield opening or half the radiation shield is removable to allow full access. PUSH OR PULL? CRYO Industries flow cryostats can be operated in push or pull operating modes - a feature not offered by some of the competitive brands. Liquid cryogen helium or nitrogen can be drawn from the main reservoir into the sample region by either: Pushing' is - simpler and easier to do. - quieter - no external pump is required - less prone to icing Pulling' - - allows storage dewar reservoir to remain at atmosphere. - is slightly more efficient at 4K - provides lower terminal temperature - offers more constant flow rate. RC102-CFM Specifications Pushing - A small pressure in the storage dewar pushes the cryogen from the storage dewar into the transfer line to the sample mount. Or, Pulling - Sucking liquid from the main storage dewar to the cold finger by using a small pump. The liquid helium is drawn from the main reservoir of the storage dewar into the sample mount using a small diaphragm (gas flow) pump, while maintaining the storage dewar near one atmosphere. Temperature range Cool down time Temperature Weight stability Vibrational amplitude (nominal, with vibration isolated manipulator support) Drift (after thermal equilibrium) LHe usage 3.5 to 325K, up to 500K optional 20 minutes typical Better than +/- 50 mk 3.2 kg 25 nm +/- 150 nm ~1.1 l/hr at 5K ~0.5 l/hr at 20K C3

GO THIN MICROSCOPY CRYOSTAT GOES THIN - Fits into the popular Olympus BX41 and more brands of microscopes Model RC102-CFM-THIN Variable Temperature Continuous Flow Optical Microscopy Cryostat:! 2.2K to 325K operating temperature range! Operates with either liquid helium or nitrogen! Operates in Push Pull modes Push - storage dewar overpressure push Pull - diaphragm pump pull! (2) 0.93 inch diameter x 0.062 inch (1.59 mm) thick optical quartz windows (0.5 mm thick window option)! Adjustable sample holder Can be adjusted right up to the window! 50 ohm heaters installed on sample mount Dual heaters for more uniform heating! 10-pin hermetic electrical feedthrough! Spare blank feedthrough port! NW25 vapor pumping port! NW25 evacuation valve with safety pressure relief! Flexible stainless steel transfer line with flow control valve! Silicon diode temperature sensor installed on cold finger! Silicon diode temperature sensor installed near sample! 30 mm thin! Solid - internal spacer More universal compact design (30 mm thick) and still with fast cooldown, high efficiency, excellent temperature stability and ultra low vibration levels. C4

1.72"[43.7mm] RADIAL SUPPORTS - NEAR ZERO THERMAL CONTRACTION - STRONG TENSION SUPPORT - LOWEST VIBRATION LEVELS - LOWEST POSITIONAL DRIFT FLEXIBLE COUPLING (2) 0.93 DIA. CLEAR VIEW CFQ WINDOWS HEIGHT ADJUSTABLE COPPER SAMPLE MOUNT COPPER COLD FINGER WITH HEATER AND TEMPERATURE SENSOR NOMOVE OPTION What is a NOMOVE support? The sample holder is supported radially with opposing support forces and no physical support from the cold finger. The thermal contraction is toward the center of the sample, resulting in the lowest movement design. The supports are designed to operate in the elastic region; supports are rigid and under tension. Further, movement toward or away from the window is theoretically zero because there is no support component in this direction. RC102-CFM-NOMOVE Temperature Cool down time Temperature Weight range stability Vibrational amplitude (nominal, with vibration isolated manipulator support) Drift (after thermal equilibrium) 4 to 325K 25 minutes typical Better than +/- 50 mk 3.2 kg less than 20 nm +/- 50 nm Easy Mounting with adjustable position support Adjust close to the microscope for more rigidity or move to fit your needs Standard Models RC102-CFM (popular standard) RC102-CFM--THIN (30 mm thick, MicThin) RC102-CFM-NOMOVE RC102-CFM-THIN+NOMOVE Add a magnetic field! Apply 2 Tesla to your samples Email us today for information on these microscopy models with magnetic fields cryo@cryoindustries.com ~1.3 l/hr at 5K LHe usage ~0.5 l/hr at 20K CRYO Industries (603) 621-9957 cryo@cryoindustries.com C5

A flow of liquid helium or nitrogen cools the sample, which can be adjusted away from or very close to the window. For high rigidity, the sample is supported on both sides. Sample distances are customer selectable. Interchangeable single thread sample holders allow for quick sample change, adjustable distances and selectable diameters and apertures. Full sample access Remove the full size cover. The sample can be quickly accessed through the radiation shield. And, the radiation shield is split in half to allow fast full access to the sample mount. 1.75 1.00 1.50 (1).56 DIA. CLEAR VIEW EPOXY SEALED WINDOWS MOUNTED INTO STRAIN RELIEVED REMOVABLE O-RING SEALED FLANGE 0.38 DIA. ADJUSTABLE SAMPLE MOUNT 1.000.281 1.125 Interchangeable Narrow Gap Magnet Kit - Converts standard microscope cryostat to Narrow Gap design for use in electromagnets Compact vacuum jacket Fits narrow 1.0 inch gap Radiation shield Changeable thread in sample holders Strain free window mounting (top window) (1).56 DIA. CLEAR VIEW O-RING SEALED WINDOW INTERCHANGEABLE NARROW GAP SHROUD KIT C6

0.75 I.D. S/S FLEX HOSE X 72 LG EVACUATION VALVE WITH NW-25 ADAPTER SAFETY PRESSURE RELIEF QUICK DISCONNECT FOR TRANSFER LINE/WORK STATION SEPARATION 1.37 O.D. HELIUM VENT WITH NW25 ADAPTER VALVE CONTROL KNOB STORAGE DEWAR INSERT LEG 19 PIN ELECTRICAL FEEDTHROUGH 3.00 A A INSTRUMENTATION HOUSING WITH EVACUATION VALVE AND SAFETY PRESSURE RELIEF 22.00 APPROX. (1) BLANK PORT LIQUID HELIUM VALVE CONTROL TUBE SECTION A-A 48.00 1.50 6.50 2.25 ACTIVATED CHARCOAL CRYOPUMP 1.81 COPPER COLD FINGER WITH WOUND HEATER AND PROV. FOR TEMPERATURE SENSOR 2.38 HELIUM TRANSFER LINE 0.50 O.D. 2.38 (2) 0.93 DIA. CLEAR VIEW CFQ WINDOWS 2.38 ADJUSTABLE COPPER SAMPLE HOLDER WITH TAPPED HOLES FOR SAMPLE MOUNTING FLOW CONTROL VALVE WITH FILTER.39 [9.9mm] 4.75 1.181 [30.0mm] FRONT VIEW TOP 1.181 [30.0mm] BOTTOM VIEW ḌWG. NO.: Industries of America, Inc 11 Industrial Way CFM-1738-102 Atkinson, N.H. 03079 REV. DATE BY TITLE: MODEL RC102 1 MSS OPTICAL MICROSCOPY CRYOGENIC WORKSTATION DWN. BY: MSS SCALE: NTS CHKD. BY: GJS DATE: 11/21/01 C7