TOPIC: KNOWLEDGE: K1.01 [2.5/2.7] An atmospheric pressure of 15.0 psia is equivalent to... A psig. B psig. C psig.

Similar documents
Pressure Measurement

Comments on Homework. Class 4 - Pressure. Atmospheric Pressure. Gauge vs. Absolute Pressure. 2. Gauge vs. Absolute Pressure. 1.

Comments on Homework. Quiz. Class 3 - Pressure. Atmospheric Pressure. 2. Gauge vs. Absolute Pressure. 1. Definitions. Temperature conversion

Pressure Measurements

Liquid Level Measurement

T208VR Series Tank Blanketing Vacuum Regulator

VACUUM TESTING PRECAST CONCRETE MANHOLES

THERMODYNAMICS, HEAT AND MASS TRANSFER TUTORIAL NO: 1 (SPECIFIC VOLUME, PRESSURE AND TEMPERATURE)

PNEUMATIC PRESSURE CONTROLLERS

Gas Physics Pressure and Flow Topics Covered:

SB AXIAL FLOW VALVES

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

SERIES 10. Pilot Operated Tank Blanketing Valve, 2" PROTECTOSEAL.

KNOWN: Mass, pressure, temperature, and specific volume of water vapor.

Best Practices for Installation of Gaseous Sample Pumps

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

SX150A. Features. Typical Applications. Description

WIKA INSTRUMENT CORPORATION

3 1 PRESSURE. This is illustrated in Fig. 3 3.

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve

Type Cronos Pressure Reducing Regulator

Pressure Measurement. Introduction. Engr325 Instrumentation. Dr Curtis Nelson 3/12/18

INSTRUMENTATION EQUIPMENT

Diagnosing EVAP systems By: Bernie Thompson

High Precision Gauge Pressure Indicators

Type R622 Pressure Reducing Regulator

Pressure measurement explained

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

SERVICE MANUAL No. I-0043

Series 7250 Ruska High-Speed Digital Pressure Controller. GE Sensing. Features

Unit A-2: List of Subjects

ANDERSON GREENWOOD TANK BLANKETING REGULATORS

3.0 Pressure Transmitter Selection

TUTORIAL. NPSHA for those who hate that stuffy word. by Jacques Chaurette p. eng. copyright 2006

North American 7339 High Pressure Gas Regulators

STANDARD FOR CONTROL VALVE SEAT LEAKAGE

EZY Chek Systems CERTIFICATION EXAM COVER SHEET

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

Pressure Control. where: p is the pressure F is the normal component of the force A is the area

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

1 Exam Prep NFPA 99 Health Care Facilities Questions and Answers (Plumbing Contractor)

VAREC 180 SERIES PRESSURE REGULATORS

The Application of Temperature and/or Pressure Correction Factors in Gas Measurement

Y692VB Series Vacuum Breaker

Third measurement MEASUREMENT OF PRESSURE

Tank Blanketing Pressure Regulators RHPS Series

94270 Vapor Guard Tank Blanketing Valve Vapor Guard Tank Blanketing Valve What is Tank Blanketing? Features How does it work?

TOTAL CAPABILITIES IN THE PIPELINE INDUSTRY. UTILITY TECHNOLOGIES INTERNATIONAL CORPORATION Cincinnati Columbus West Jefferson

Application Worksheet

Lab 1c Isentropic Blow-down Process and Discharge Coefficient

Exhibit 4. Determination of Static Pressure Performance of the Healy Clean Air Separator (Executive Orders VR-201-N and VR-202-N)

Liquid level measurement using hydrostatic pressure and buoyancy

Pressure Measurement

DRAFT. Operating Procedures for the NPDGamma Liquid Hydrogen Target in TA-53, Building MPF-35

Phys101 Lectures Fluids I. Key points: Pressure and Pascal s Principle Buoyancy and Archimedes Principle. Ref: 10-1,2,3,4,5,6,7.

GP1 & GP2. Electropneumatic Regulators FOR PRESSURE CONTROL TO 1,000 PSI

D R A F T. Operating Procedures for the NPDGamma Liquid Hydrogen Target at the BL 13. Version 1.00

European Technical Standard Order (ETSO)

Rosemount 3159 Nuclear Qualified Remote Diaphragm Seal

Engineering Information. Flow Data. Flow Data. Importance of Valve Sizing. Estimating Cv or Orifice Size:

PALO VERDE NUCLEAR GENERATING STATION

Pressure measurement Applying remote seal, isolation diaphragms between process fluids and transmitters

8. Now plot on the following grid the values of T (K) and V from the table above, and connect the points.

STANDARD OPERATING PROCEDURES

Maximum Pressure Differential and Maximum Inlet Pressure for Various Soft-Seated Valve Materials* Introduction. Body Pressure Ratings

North American Orifice Metering System

Appendix A 1. -STATIC LEAK TEST (taken from BAAQMD test procedure ST-30)

KING-GAGE. Calibration Instruction Manual. D/P LiquiSeal Purge Control and D/P Purge Control

Type 299 Pressure Reducing Regulators

Petro-Chemical & Analyzer Sampling Systems

Design and Safety Document for the Vacuum Windows of the NPDGamma Liquid Hydrogen Target at SNS

Petro-Chemical & Analyzer Sampling Systems

1811G/H PITOT-STATIC TEST SET

Models 461-S, 461-8S and S Regulators. R-1330 Rev. 7

Types ACE95 and ACE95Sr Tank Blanketing Valves

66 Series Direct-Operated Regulators and Vacuum Service Equipment

Device Description. Operating Information. CP Q (eq. 1) GT. Technical Bulletin TB-0607-CFP Hawkeye Industries Critical Flow Prover

Measuring Pressure in Medical Sterilizers

Fluke 700 Series pressure modules

B. Assemble the Method-25 sample train with a heated probe/filter.

Quick Reference Technical Data

PRESSURE SENSOR - ABSOLUTE (0 TO 700 kpa)

ELECTRONIC VALVE SIZING AND SELECTION

Instrumentation. Introduction to Instrumentation. Revised 11/30/18 1

THE INNER WORKINGS OF A SIPHON Jacques Chaurette p. eng. January 2003

METHOD 2A - DIRECT MEASUREMENT OF GAS VOLUME THROUGH PIPES AND SMALL DUCTS. NOTE: This method does not include all of the

PRO-50 Instrument Supply Regulator

INSTRUCTIONS FOR MODELS UPH & UPHS HIGH FLOW, HIGH PURITY GAS REGULATORS

Operating Instructions

Series Ruska Digital Pressure Indicator. GE Sensing & Inspection Technologies. Features

General. Rugged, Reliable with Value-added Features. Pipe Sizes. Temperature Limits. Spring Ranges. Buried Service. Increased Outlet Pipe Sizes

Instruction Bulletin Addendum For Pressure-Balanced In Situ Oxygen Probes

Noninvasive Blood Pressure Measurement. D. J. McMahon rev cewood

Gauge Pressure, Absolute Pressure, and Pressure Measurement

InstrumentationTools.com

DESIGN DATA. Dry 105a. September 5, 2008

CONTROL VALVE SEAT LEAKAGE

CSC-2000 SERIES. Reset Volume Controllers MADE IN U.S.A. DESCRIPTION MODELS SPECIFICATIONS ORDERING

METHOD 2D - MEASUREMENT OF GAS VOLUME FLOW RATES IN SMALL PIPES AND DUCTS. NOTE: This method does not include all of the

Efficient Pigging of Gathering Lines. Energy Management Workshop for Upstream and Midstream Operations

Transcription:

P73 An atmospheric pressure of 15.0 psia is equivalent to... A. 30.0 psig. B. 29.4 psig. C. 14.7 psig. D. 0.0 psig. ANSWER: D. P273 A pressure gauge on a condenser reads 27.0 inches Hg vacuum. What is the absolute pressure corresponding to this vacuum? (Assume a standard atmospheric pressure of 15.0 psia.) A. 14.0 psia B. 13.5 psia C. 1.5 psia D. 1.0 psia ANSWER: C. -1-

P473 Assuming a standard atmospheric pressure of 15.0 psia, 5.0 inches Hg vacuum is equivalent to... A. 2.5 psia. B. 5.0 psia. C. 10.0 psia. D. 12.5 psia. ANSWER: D. P873 If a main steam line pressure gauge reads 900 psig, what is the absolute pressure? A. 870 psia B. 885 psia C. 915 psia D. 930 psia ANSWER: C. -2-

P1173 Which one of the following is equivalent to 5 psia? A. 20 psig B. 10 psig C. 10 inches of mercury (Hg) vacuum D. 20 inches of mercury (Hg) vacuum ANSWER: D. P1273 Which one of the following is arranged from the lowest pressure to the highest pressure? A. 8 psia, 20 inches Hg absolute, 2 psig B. 8 psia, 2 psig, 20 inches Hg absolute C. 20 inches Hg absolute, 2 psig, 8 psia D. 20 inches Hg absolute, 8 psia, 2 psig ANSWER: A. -3-

P1573 Which one of the following is arranged from the highest pressure to the lowest pressure? A. 2 psig, 20 inches Hg absolute, 8 psia B. 2 psig, 8 psia, 20 inches Hg absolute C. 8 psia, 20 inches Hg absolute, 2 psig D. 8 psia, 2 psig, 20 inches Hg absolute ANSWER: A. P1773 Which one of the following is approximately equivalent to 2 psig? A. 11 psia B. 13 psia C. 15 psia D. 17 psia ANSWER: D. -4-

P2073 Which one of the following is arranged from the lowest pressure to the highest pressure? A. 2 psig, 12 inches Hg absolute, 8 psia B. 2 psig, 18 inches Hg absolute, 8 psia C. 12 psia, 20 inches Hg absolute, 2 psig D. 12 psia, 30 inches Hg absolute, 2 psig ANSWER: D. P2173 Which one of the following is the approximate condenser vacuum when condenser pressure is 16 inches Hg absolute? A. 4 inches Hg vacuum B. 8 inches Hg vacuum C. 12 inches Hg vacuum D. 14 inches Hg vacuum ANSWER: D. -5-

P2273 Which one of the following is arranged from the highest pressure to the lowest pressure? A. 2 psig, 12 inches Hg absolute, 8 psia B. 2 psig, 18 inches Hg absolute, 8 psia C. 12 psia, 20 inches Hg absolute, 2 psig D. 12 psia, 30 inches Hg absolute, 2 psig ANSWER: B. -6-

P374 (B373) Refer to the drawing of two water storage tanks with four differential pressure (D/P) level detectors (see figure below). The tanks are identical and are being maintained at the same constant water level with 17 psia gas pressure above the water. The tanks are surrounded by standard atmospheric pressure. The temperature of the water in the tanks and reference legs is 70 F. Which one of the level detectors is sensing the greatest D/P? A. No. 1 B. No. 2 C. No. 3 D. No. 4 ANSWER: B. -7-

P573 (B1873) An enclosed water storage tank is pressurized with nitrogen to prevent air inleakage. Tank pressure is allowed to vary as water level changes. A differential pressure detector is used to measure the tank level. To achieve the most accurate level measurement, the low pressure side of the detector should sense which one of the following? A. The pressure at the midline of the tank. B. The pressure of the atmosphere surrounding the tank. C. The pressure of a column of water external to the tank. D. The pressure of the gas space at the top of the tank. ANSWER: D. -8-

P709 (B710) Refer to the drawing of two water storage tanks with four differential pressure (D/P) level detectors (see figure below). The tanks are identical and are being maintained at 17 psia and 70 percent water level (calibration conditions). They are located in a building that is currently at atmospheric pressure. If the building ventilation system creates a vacuum in the building, which level detectors will provide the lowest level indications? A. 1 and 3 B. 1 and 4 C. 2 and 3 D. 2 and 4 ANSWER: B. -9-

P1673 (B1174) Refer to the drawing of two water storage tanks with four differential pressure (D/P) level detectors (see figure below). The tanks are identical and are being maintained at 2 psig overpressure, the same constant water level, and a temperature of 60 F. They are surrounded by atmospheric pressure. If a leak in the top of each tank causes a complete loss of overpressure, which detector(s) will produce a lower level indication? A. No. 1 only B. No. 2 only C. No. 1 and 4 D. No. 2 and 3 ANSWER: D. -10-

P2373 (B2373) Refer to the drawing of two water storage tanks with four differential pressure (D/P) level detectors (see figure below). The tanks are identical and are being maintained at 2 psig overpressure, 60 F, and the same constant water level. The tanks are located within a sealed containment structure that is being maintained at standard atmospheric pressure. All level detectors have been calibrated and are producing the same level indication. If a ventilation malfunction causes the containment structure pressure to decrease to 13 psia, which detectors will produce the lowest level indications? A. 1 and 3 B. 2 and 4 C. 1 and 4 D. 2 and 3 ANSWER: C. -11-

P2574 (B2573) Refer to the drawing of two water storage tanks with four differential pressure (D/P) level detectors (see figure below). The tanks are identical and are being maintained at 2 psig overpressure, 60 F, and the same constant water level. The tanks are located within a sealed containment structure that is being maintained at standard atmospheric pressure. All level detectors have been calibrated and are producing the same level indication. If a ventilation malfunction causes the containment structure pressure to decrease to 13 psia, which detectors will produce the highest level indications? A. 1 and 2 B. 3 and 4 C. 1 and 4 D. 2 and 3 ANSWER: D. -12-

P2673 (B73) Refer to the drawing of a water-filled manometer (see figure below). The manometer is installed across an orifice in a ventilation duct to determine the direction of airflow. With the manometer conditions as shown, the pressure at P1 is than P2; and the direction of airflow is. A. greater; left to right B. greater; right to left C. less; left to right D. less; right to left ANSWER: A. -13-

P2873 (B1073) Refer to the drawing of two water storage tanks with four differential pressure (D/P) level detectors (see figure below). The tanks are identical with equal water levels and 20 psia gas pressure above the water. The tanks are surrounded by standard atmospheric pressure. The temperature of the water in the tanks and reference legs is 70 F. If each detector experiences a ruptured diaphragm, which detector(s) will produce a lower level indication? (Assume that actual tank and reference leg water levels do not change.) A. No. 1 only B. No. 2 only C. No. 1, 2, and 3 D. No. 2, 3, and 4 ANSWER: D. -14-

P2973 (B673) Refer to the drawing of a water-filled manometer (see figure below). The manometer is installed across an orifice in a ventilation duct to determine the direction of airflow. With the manometer conditions as shown, the pressure at P1 is than P2; and the direction of airflow is. A. less; right to left B. less; left to right C. greater; right to left D. greater; left to right ANSWER: A. -15-

P3173 (B3173) A water storage tank is vented to atmosphere. The tank is located at sea level and contains 100,000 gallons of 80 F water. A pressure gauge at the bottom of the tank reads 5.6 psig. What is the approximate water level in the tank? A. 13 feet B. 17 feet C. 21 feet D. 25 feet ANSWER: A. -16-

P3673 (B3673) Refer to the drawing of a tank with a differential pressure (D/P) level detector (see figure below). If the tank contains 30 feet of water at 60 F, what is the approximate D/P sensed by the detector? A. 7 psid B. 13 psid C. 20 psid D. 28 psid ANSWER: B. -17-

P3873 (B3873) A water storage tank is vented to atmosphere. The tank is located at sea level and contains 100,000 gallons of water at 80 F. A pressure gauge at the bottom of the tank reads 7.3 psig. What is the approximate water level in the tank? A. 13 feet B. 17 feet C. 21 feet D. 25 feet ANSWER: B. P4537 (B4537) A water storage tank is vented to atmosphere. The tank is located at sea level and contains 100,000 gallons of water at 80 F. A pressure gauge at the bottom of the tank reads 9.0 psig. What is the approximate water level in the tank? A. 13 feet B. 17 feet C. 21 feet D. 25 feet ANSWER: C. -18-

P4837 (B4837) Refer to the drawing of two water storage tanks with four differential pressure (D/P) level detectors (see figure below). The tanks are identical and are being maintained at 2 psig overpressure, the same constant water level, and a temperature of 60 F. The tanks are surrounded by atmospheric pressure. All level detectors have been calibrated and are producing the same level indication. If a leak in the top of each tank causes a complete loss of overpressure in both tanks, which detector(s) will produce the highest level indication(s)? A. No. 1 only B. No. 2 only C. No. 1 and 4 D. No. 2 and 3 ANSWER: C. -19-

P5837 (B5837) Refer to the drawing of an open water storage tank with a differential pressure (D/P) level indicator that is vented to atmosphere (see figure below). Both the tank and the level indicator are surrounded by standard atmospheric pressure. Tank water temperature is 70 F. The D/P level indicator is sensing a differential pressure of 4.0 psi. What is the water level in the tank above the instrument penetration? A. 9.2 feet B. 16.7 feet C. 24.7 feet D. 43.2 feet ANSWER: A. -20-