HERZ-Motorised flow controler

Similar documents
HERZ - Compact Flow Controller with

Differential pressure controller (PN 16) AHP - return mounting, adjustable setting

HERZ - Compact Flow Controller with

Automatic Balancing Valve Pressure difference controller with integrated flow limiter AB-PM DN

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

AVP-F. p setting range (bar) Code No. 003H6200

AVPQ/AVPQ-F, PN 16. Application

Dynamic Valve Type RA-DV Pressure Independent Radiator Valve

STAP. Differential pressure controller DN 15-50

differential pressure regulating valve - threaded

Upgradable balancing valves USV

Two-port valves, male threaded, PN25

V5001P. Kombi-Auto Differential Pressure Control Valve. Product specification sheet

Differential pressure controller with flow limitation (PN 16, 25, 40) AFPB / VFQ 2(1) AFPB-F / VFQ 2(1)

Pressure reduction controller (PN 16, 25, 40)

Radiator valves VDN2.. VEN2.. VUN2..

Differential pressure control and flow limiter AVPB/AVPB-F, PN 16

BTV. Internally threaded 2-way control valve. Flow characteristics. Function

Chrome plated radiator valves type RA-NCX and lockshield valves type RLV-CX

Radiator valves VDN1.. VEN1..

RA-N radiator valves with integrated presetting and self-sealing tailpiece

Versions. Benefits. Balancing DN15-32 DN40 DN50 DN15, DN20, DN25, DN32, DN40, DN50. Dimensions

B2KL: 6-way ball valve with male thread, PN 16

TBV-CM. Combined control & balancing valves for small terminal units For modulating control

TA-FUSION-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics

Multifunctional Thermostatic Circulation Valve MTCV - Lead free brass

VZL valve - 2/3/4-way

TA-COMPACT-P. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve (PIBCV)

Automatic balancing valves ASV

Pressure independent balancing and control valve AB-QM DN

Differential pressure controller (PN 16) AVPL return mounting, adjustable setting

Pressure Reducing Valve DMV 755

Pressure independent control valve (PICV) FLOWMATIC

Overview of types. Technical data. Safety notes

STAD. Balancing valves DN 15-50

Automatic balancing valves ASV

Automatic balancing valves

TA-Modulator. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve for modulating control

2-port and 3-port valves PN 16

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

Rp [ ] Sv min. [ ] C215QP-B 15 1/ C215QP-D 15 1/ C220QP-F 20 3/ [ ]

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

V5012C Kombi-DP Diaphragm Unit RETROFIT AUTOMATIC DP CONTROLLER

STAP. Differential pressure controller DN

Ballorex Dynamic Description. Versions. Benefits. Balancing

Technical data sheet. Type overview. Technical data. Safety notes. T5-R2.. Open-close en v Subject to changes 1 / 3

GM Series Dual-Block Multi-Function Gas Control Valves

2-port seat valves PN25 with externally threaded connections

STAD-C. Balancing valves DN 15-50

Differential pressure controller (PN 16) AVPL - return mounting, adjustable setting

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

STAG. Balancing valves Balancing valve with grooved ends DN

MZX. Three-Port Seat Valves SPECIFICIATIONS AND GUIDE TO SELECTION

CLASS TLP Pressure Reducing Valve

Product Sheet Pre-Fabricated Flushing Bypass Assembly for Terminal Applications Mini-Flush 40

Pressure reducing valves Index

TRV-2, TRV-2S. Thermostatic radiator valves With presetting

STAD. Balancing valves DN (MD60, MD61, MD62)

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

STV / STVL. Danfoss STV series of balancing valves provide testing and balancing of circuit flow for hydronic heating or cooling systems.

STAD-D. Balancing valves Balancing valve for domestic water systems, DN Balancing valves

Serie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E

Hycocon. Technical information. Das Qualitätsmanagementsystem von Oventrop ist gemäß DIN-EN-ISO 9001 zertifiziert.

STAP. Differential pressure controllers DN , ANSI flanges

JRGURED Pressure reducing valves

Three-port valves. Special versions with special stem sealing gland for: High temperature hot water C Thermo oils

Two-port seat valves

Type overview. R B2 en-gb subject to changes 1

C 10 Pressure Reducing Valve

Overview of types. Technical data

Installation, commissioning and servicing instructions

Rate of Flow Valve Series 120

DN 1/2" to 2" Female BSP + 0 C C Max Pressure : 16 Bars Specifications : Stainless steel removable filter Female / Female With draining valve

Pressure Independent Control Series

VARIABLE ORIFICE BALANCING VALVE PN 25 TECHNICAL DATA SHEET. Approved by*: Main features:

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

Pressure relief valve DHV 716 set range: 0,5-10,0 bar

TBV-CM. Combined control & balancing valves for small terminal units For modulating control NPT threads

4/2 way Pneumatic Solenoid Valve

Serie ECO 3F. Flanged back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

Technote. Frese PV-SIGMA Compact Dynamic Pressure and Flow Regulation. Description. Application. Operation. Features. Benefits.

3-port seat valves with externally threaded connection, PN 16

Type 4708 Supply Pressure Regulator

Differential Pressure Control Valve. Passim

Type 4708 Supply Pressure Regulator

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X

CALEFFI. Ball zone valves. series /03 GB

Installation Instructions

Self-operated Pressure Regulators for special applications

KTM 50 (DN ) Installation, maintenance and operating instructions

776 Cryogenic Safety Valve

Description Pressure range Connection thread Device Page

STAP. Differential pressure controllers DN , ANSI fl anges

Products no longer available

STA. Double regulating valves DN 15-50

Installation, commissioning and servicing instructions

WW-730. Pressure Sustaining/Relief Control Valve

Transcription:

HERZ-Motorised flow controler Control and regulating valve Data sheet 46, Issue 214 Dimensions in mm 4 close dimension 9,35 M DN G H1 H2 H2 + Actuator B1 B2 1 2 M 1 46 11 15 3/4 G 66 59 73 134 49 63 48 81 28 x 1,5 1 46 12 1 G 76 6 73 134 51 68,5 48 85 28 x 1,5 1 46 13 25 1 1/4 flatsealing 76 6 73 134 51 68,5 48 85 28 x 1,5 1 46 14 32 1½ flatsealing 28 x 1,5 1 46 15 4 1¾ flatsealing 132 86 95 156 75 47 7 81 28 x 1,5 1 46 16 5 2 3 8 flatsealing 14 86 95 156 75 47 7 81 28 x 1,5 Technical data Max. operating pressure 16 bar Max. differential pressure on the body 4 bar Min. operating temperature 2 C (pure water) Min. operating temperature - C (frost protection) Max. operating temperature up to DN 32 13 C from DN 4 11 C ift 4 mm The integrated control unit together with the actuating drive is responsible for modular control. Various actuating drives might be used (see also chapter: Accessories and spare parts). Page 1

Application The Pressure Independent Balancing Control Valve (PIBCV) is used in all heating and cooling systems with circulation pumps. The valve automatically maintains flow to the required part of the system at the set rate by measuring and immediately adjusting to any variation in pressure. No additional measurements are necessary and the correct flow rate is achieved at all operating conditions. The diaphragm responds to the pressure upstream and downstream of the regulating valve (via an internal impulse line). The valve settings directly affect the volumetric flow through the valve. It is thus possible to set the maximum flow rate based on the flow chart when the valve is fitted. This allows for the balancing of heating circuits, cooling water systems, ceiling cooling and heating panels, air heaters, etc. without any need to first assess the pressure variations in the system. The valve s principal application is as a control valve for terminal units. As it is pressure independant, it maximizes energy efficiency and negates the requirement for control valves. In addition to the PIBCV, HERZ Ball Valves (219) can be fitted in the corresponding flow pipe. If control measurements of the flow rate are required, then STRÖMAX-M valves (417 M, 4117 M, 4217 GM) must be fitted instead. Materials Body: dezincification-resistant brass Membranes and O-rings: EPDM Water purity in accordance with the ÖNORM H 5195 and VDI 35 standards Ethylene and propylene glycol can be mixed to a ratio of 15-45 vol. [%]. Installation The valve is fitted in the return in any orientation. The arrow on the valve body should align with the direction of flow. It is recommended that an isolation valve is fitted both upstream and downstream of the PIBCV. The PIBCV may be isolated using the HERZ pre-setting key (1 46 2). For pre-setting, turn the key right (clockwise) up to the stop. The setting should then read < %. kvs-values DN 15,4 m 3 /h DN 32 2,5 m 3 /h DN,9 m 3 /h DN 4 5 m 3 /h DN 25 1,9 m 3 /h DN 5 5 m 3 /h Page 2

Accessories and spare parts 1 4117.. HERZ-STRÖMAX circuit control valves, angle version 1 4217.. HERZ- STRÖMAX circuit control valves, straight version 1 417.. HERZ- STRÖMAX circuit control valves with integrated metering orifice plate 1 4125.. HERZ shut-off valves, angle version 1 4115.. HERZ shut-off valves, angle version 1 4215.. HERZ shut-off valves, straight version, also variants with male threads. For details please refer to the corresponding data sheets. 1 284 1 test point for HERZ circuit control valve, blue cap (return) 1 284 2 test point for HERZ circuit control valve, red cap (flow) 1 284 11 test point for HERZ circuit control valve, extended model, blue cap (return) 1 284 12 test point for HERZ circuit control valve, extended model, red cap (flow) 1 284 21 HERZ test point with draining function, blue cap (return) 1 284 22 HERZ test point with draining function, red cap (flow) 1 284 test point adapter set 1 779.. HERZ actuating drive for two-point or pulse control 1 799.. HERZ actuating drive for continuous control 1 273 9 screw plug 1/4 Pipe connections (with cone seal) for metal pipes Pipe 8 1 12 14 15 16 18 22 Valve DN 15 DN 15 DN 15 DN 15 DN 15 DN 15 DN 15 DN Nut G 3/4 3/4 3/4 3/4 3/4 3/4 3/4 1 with Connection 1 6274 18 1 6274 1 6274 1 1 6274 2 1 6274 3 1 6274 4 1 6273 1 metallic seal with soft Connection 1 6276 12 1 6276 14 1 6276 15 1 6276 16 1 6276 18 seal Compression union for calibrated soft steel and copper pipes (for details please refer to the corresponding data sheets) Pipe connections (with cone seal) for plastic pipes Pipe 1 x 1,3 14 x 2 15 x 2,5 16 x 2 16 x 2,2 17 x 2 17 x 2,5 18 x 2,5 18 x 2 Valve DN 15 DN 15 DN 15 DN 15 DN 15 DN 15 DN 15 DN 15 DN 15 Nut G 3/4 3/4 3/4 3/4 3/4 3/4 3/4 1 Connection 1 698 18 1 698 2 1 698 16 1 698 3 1 698 12 1 698 4 1 698 5 1 698 6 1 698 7 Pipe x 2 x 3,5 x 2,5 25 x 3,5 26 x 3 Valve DN 15 DN 15 DN 15 Nut G 3/4 3/4 3/4 Connection 1 698 8 1 698 1 1 698 11 Valve DN 15 DN 15 DN 15 Nut G 1 1 Connection 1 6198 12 1 698 1 698 1 Plastic pipe connections for PE- X, PB and aluminium composite pipes (for details please refer to the corresponding data sheets) When installing soft steel or copper pipes with a pipe wall of 1 mm or less with compression unions, we recommend the use of support sleeves (order no.: 1 674 xx). When installing plastic pipes, suitable calibration tools are needed. Please refer to our instruction manual. For proper installation use silicone oil to lubricate the thread of the locking nut or olive screw as well as the olive. 1 62.. Iron pipe connection, consisting of nut, seal and pipe nipple with male pipe thread 1 6236.. Soldering connection, consisting of nut, seal and soldering nipple 1 624.. Welding connection, consisting of nut, seal and welding nipple 1 621.. Iron pipe connection consisting of nut, seal and pipe nipple with male pipe thread 1 6235.. Soldering connection, consisting of nut, seal and soldering nipple Page 3

HERZ-Connection elements R R 62/6221 D R 621/6211 6235 D R Ø R 6236 Ø 624/6241 Ø Valvedimension Ordernumber R D ø DN 15 1 621 21 3/4 1/2 25 DN 15 1 621 26 3/4 1/2 21 DN 15 1 621 11 3/4 1/2 3 DN 15 1 6211 3/4 3/8 24 DN 1 621 2 1 3/4 3 DN 1 621 12 1 1/2 3 DN 25 1 62 63 1¼ 1 35 DN 32 1 62 64 1½ 1 4 DN 4 1 62 65 1¾ 1½ 49 DN 5 1 62 66 2¾8 2 56 DN 15 1 6235 21 3/4 12 13 DN 15 1 6235 31 3/4 15 13 DN 15 1 6235 41 3/4 18 18 DN 1 6235 12 1 18 18 DN 25 1 6236 63 1¼ 28 24 DN 32 1 6236 64 1½ 35 27 DN 4 1 6236 65 1¾ 42 31 DN 5 1 6236 66 2¾8 54 37 DN 25 1 624 63 1¼ 34 51 DN 32 1 624 64 1½ 42 54 DN 4 1 624 65 1¾ 48 57 DN 5 1 624 66 2¾8 6 6 B A Valvedimension Ordernumber A B DN 15 P 714 81 G 3/4 14 x 2 5 DN 15 P 716 81 G 3/4 16 x 2 5 DN 15 P 718 81 G 3/4 18 x 2 5 DN 15 P 7 81 G 3/4 x 2 5 DN 25 P 726 43 G 1¼ 26 x 3 5 DN 25 P 732 43 G 1¼ 32 x 3 5 DN 25 P 74 43 G 1¼ 4 x 3,5 7 DN 32 P 732 44 G 1½ 32 x 3 5 DN 32 P 74 44 G 1½ 4 x 3,5 7 DN 32 P 75 44 G 1½ 5 x 4 7 Tips The valves must be installed for the correct application using clean fittings. A HERZ strainer (4111) should be fitted to prevent impurities. Test points Two test points are fitted on the same side of the valve and factory sealed. Thanks to this arrangement they are easily accessible and measurement devices can be quickly fitted, no matter in what position the valve has been installed. Pre-setting The valve setting is clearly shown in percent. The preset value can be easily adjusted. The preset PIBCV can be isolated at any time or adjusted to the required flow rate. 1 46 2 Page 4

Application examples Fan coil system with variable speed pump Two-point control Modulating control Fan coil system with constant-speed pump Two-point control Modulating control 2117 2117 Please note: all diagrams are indicative in nature and do not claim to be complete. Page 5

Art. Nr. 1 41 21, 1 46 11 DN 15,15,1,5 PRESETTING [%] 25 15 1 5 [l/s] Page 6

Art. Nr. 1 41 22, 1 46 12 DN,3,25,,15,1,5 PRESETTING[%] 5 4 3 1 [l/s] Page 7

Art. Nr. 1 41 23, 1 46 13 DN 25,6,5,4,3,,1 PRESETTING [%] 4 3 1 [l/s] Page 8

Art. Nr. 1 41 24, 1 46 14 DN 32,8,7,6,5,4,3,,1 PRESETTING [%] 25 15 1 5 [l/s] Page 9

Art. Nr. 1 41 25, 1 46 15 DN 4 1,6 1,,8,4 PRESETTING [%] 5 4 3 1 [l/s] Page 1

Art. Nr. 1 41 26, 1 46 16 DN 5 1,5 1,,5 PRESETTING [%] 5 4 3 1 [l/s] Page 11