X-Tech CLV User Manual. English

Similar documents
RG3100 and RG3100Ice Regulator System

RG1200 Regulator System

Flathead VI Owner s Manual

WARNING: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

RG2200 BC Integrated Octopus

INDEPENDENT TESTS SHOW THAT THE TX100 REGULATOR, EASILY EXCEEDS THE REQUIREMENTS OF THE EUROPEAN REGULATOR PERFORMANCE STANDARD EN250.

Gemini Owner s Manual

In this manual; Warnings, Cautions and Notes calls your attention to information provided to help ensure your safety. Always dive safely.

WARNING: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

REGULATOR OWNER S GUIDE

R0001. Northern Diver. HYDRA Regulator Manual

Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.

B.C.D. Buoyancy Compensator Device User Manual

DIVATOR RS4 USER MANUAL

SHERWOOD OWNER S MANUAL

RG1200 Service and Repair Manual

SHERWOOD PRO OWNER S MANUAL

SCUBATECH. Instructions for use. Demand regulators. Series models R1, R2, R3,R5, V2 (ICE, PRO, TEC, SPECIAL, OCTO, MONO)

AIR2-5 th Generation Octopus / BC inflator

ADMINISTRATION GENERAL INFORMATION OCEANIC ADMINISTRATION FOR PRODUCT SERVICE PROCEDURES

Regulators Atemregler Détendeurs Erogatori Reguladores Ademautomat Reguladores Регуляторы Reduktorok Automaty oddechowe Regulátory Regulatori

Regulator Owner's Manual

Service and Repair Operative Manual MC9 1 st STAGE. MC9 1 st Stage. 1 st STAGE MC9. Jannuary Rev. MC9 /B Ed. C/13

DIVATOR THE COMPLETE DIVING SYSTEM INTERSPIRO PRODUCT CATALOG

Regulator Owner s Manual. Regulator Owner s Manual

O2 TECH REG O24/Alpha 7 Regulator owner's guide

12S 1st Stage. -Maintenance Procedure-

Service and Repair Manual

AP100 AUTO AIR. User Instruction Manual

Training. Testor Training Manual

Toll Free: (888) M A D E I N T H E U. S. A.

CSA Sample Draw Aspirator Adapter Operator s Manual

J800 HOPE BUOYANCY COMPENSATOR OWNER S MANUAL

G250/G250 HP Compatibility of Upgrade Kit

Pressure Regulators. Operating Instructions. Instrumentation

Regulator Owner Manual

Where Depth of Experience Produces the Height of Innovation. OWNER S MANUAL BRUT SRB

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

Manuale d uso Direction for use Manuel d instructions Bedienungsanleitung Manual de istrucciones Pуководство 潜水呼吸调节器使用手册

SCUBAPRO Repair Guide. S600-S550 Second Stages

REGULATORS OWNER S MANUAL

Budget Range Operators Handbook

Regulator Owner s Manual...

SuperFlow Scuba Regulator Assembly

AIR SOURCE. Owner's Manual

Yoke Block Instruction Manual

Concentrate Distribution System (Stand Mounted) A-CDS-70-X & A-CDS-TANK-X-ST Industrial Drive, Orlinda, TN 37141

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10

Pressure Differential Automatic Manifold For LPG. PDH1000 Series. LPG Installation & Operations Instructions

LEAK SEALING SYSTEMS

Balanced SCUBA Second Stage Regulator (P/N ) Maintenance Manual Contents

Version 3.0. USER GUIDE - Jetstream Mk3 - Jetstream Classic - Jetstream Octopus

Regulators repair and maintenance. 1st stage MC5. MC5 INT HZ MC5 DIN 300 bar HZ

MAINTENANCE PROCEDURE FOR X 650

Yoke Block Instruction Manual

SECTION FIVE: OP-1B (XLDS) HIGH PRESSURE AIR STORAGE SYSTEM (HPASS) 02/17/2012

Freedom8 ShoeBox Compressor Manual

J Air and Water Kit Instructions Part# 02584

Balanced SCUBA Second Stage Regulator (P/N ) Contents

OPERATION MANUAL NTF-15

PDY TON HYDRAULIC CRIMPING TOOL WARNING

/ Air Line Kit AL - M1202. / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651

Product Information News

CS150 CAP STAPLER OWNER S MANUAL

ZEOS 28 ZEOS 38 HYDROS 40 HYDROS 50 READ CAREFULLY. YOUR COMFORT AND SAFETY IS WORTH MORE THAN 15 MINUTES.

Product Information News September 26, 2003

98695A01 - THE CONCEPT OF THE DIVATOR FAMILY

SCK01 AIR COMPRESSOR KIT WITH QUICK FITTINGS - SPRAY/BLOW/OIL GUN, TYRE INFLATOR & HOSE

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

ZEOS 28 ZEOS 38 HYDROS 40 HYDROS 50. User manual English

D Series Air and Water Kit Part# 02550

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS


Universal Valve Company Inc

LTS BCD USER GUIDE. Hollis (2014) Doc r01 (8/29/14)

DS05C,D,G Dial Set Pressure Regulating Valves

Powers Controls D Day-Night Thermostats

DS06D,G Dial Set Pressure Regulating Valve

MODEL NUMBER: AS18-2 USER GUIDE

CARTRIDGE FILTERS. Models: CF50, CF75, CF100, CF150,

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

User Instruction Manual

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

OPERATION MANUAL NTF-60 Plus

High Pressure Inlet Kits for CONCOA BlendMites and BlendMasters

TactAir PCP Fill Kit/Adapter. Operation Manual

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION

Deep Six Signature Regulator Technician Service Manual

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual

170-CG Feed Unit SPONGE-JET USER MANUAL. Sponge-Jet, Inc. (USA) 14 Patterson Lane Newington, NH

THERE WHEN YOU NEED IT

RK-IR Sample Draw Aspirator Adapter Operator s Manual

RK LEL Sample Draw Aspirator Adapter Operator s Manual

Apollo A-320 NITROX and A-320 CMF First Stage Regulators

fenzy x4 technical manual PN (orange) PN (black)

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

RB70 Automatic Diluent Valve Maintenance Manual. Version 1.1 November 2006 Written by Tino de Rijk. Page 1 of 23

MMR Air Mask With. with Quick-Connect Hose

Transcription:

X-Tech CLV User Manual English

Sommary 03. Use 04. Maintenance 05. Caution 06. Technical specifications 08. Cold water use (<10 C) 09. Warranty 2

Congratulations on your recent purchase of a Dive System regulator and thank you for tour support. Dive System regulators, manufactured with corrosion resistant materials, use the most modern techniques for optimum air delivery and comfort during the dive. Diving regulators deliver air at current ambient pressure upon demand. The use of regulators requires proper training by a certified agency. IMPORTANT: The use of regulators in sport diving is limited to depth of 120 feet / 40 meters. This depth limit can be extended to 150 feet / 50 meters, for professional use. To exceed these limits may lead to high risk situations (narcosis, etc..). USE A regulator must be used in combination with a pressure gauge. The regulator can mounted on a diving cylinder in either of two configurations : Yoke connector (up to 3300 psi / 230 bars) ISO/DIS 1209-1 : 1998 230 and 300 bars DIN connector (up to 3300 or 4400 psi) ISO/DIS 1209-2 & 3 : 1998 Gli erogatori DiveSystem sono equipaggiati con porte di bassa pressione (LP) da 3/8 e porte di alta pressione (HP) da 7/16. Le fruste LP di jacket e muta stagna possono essere connesse con le porte LP disponibili, la frusta HP del manometro deve essere connessa ad una porta HP. Per un livello superiore di sicurezza è consigliabile l uso di una bombola con doppio connettore e l uso di un erogatore indipendente di backup. Dive System regulators are equipped with low pressure (LP) ports of 3/8 and high pressure (HP) ports of 7/16. Buoyancy compensators LP hose and drysuit hose can be installed on available LP ports. The pressure gauge needs to be installed on the HP port. For added security, the use of a cylinder with dual outlet valve (Y-valve) will allow for a secondary back-up regulator. WARNING: This regulator, complying with EN 250, is not intended for more than one diver to breathe from at the same time. If this regulator is configured and used by more than one diver at the same time, then cold water and breathing performance may not fulfill the requirements of EN 250. RECOMMENDATIONS: A regulator will offer optimum performance in the following situations : Water temperature between 10 C (50 F) to 35 C (95 F). Air supply must be conform to the breathing air standard. 3

MAINTENANCE BEFORE THE DIVE: Please note that the procedures outlined below do not apply to cold water regulators which requires specific preparation and use. Remove the dust protector and install the first stage on the valve by tightening the yoke screw or DIN kit (do not over tighten). Open the valve completely and check the cylinder pressure on the pressure gauge. Purge the second stage by depressing the purge button for a few seconds to ensure proper air delivery. Put the 2nd stage in Dive mode Venturi + and Sens. Adjust. knob open Take several inhalations on the second stage while on the surface before starting your dive. AFTER THE DIVE: Close the cylinder completely (turn off the valve). Remove any residual air from the regulator by purging the second stage (depress the purge button). Remove the regulator by unscrewing the yoke DIN connector. After drying the dust cap, replace it over the yoke retainer WARNING: Do not blow high pressure air directly on the regulator filter to prevent humidity from entering the high pressure chamber. 4

CAUTION Do not leave your regulator exposed to direct sunlight if possible. Do not use the regulator first stage as a handle to carry the cylinder. After every dive quickly remove the regulator from the cylinder to preserve it from any shock damage. In every case always handle your with care. CLEANING After the dive your regulator should be cleaned with fresh water. Before rinsing your first stage, make sure the dust cap is in place. Dive System recommends the use of cleaning/desinfection product (cold process) for the destruction of the germs on regulators. STORAGE After the regulator has been rinsed and dried, store it if possible by hanging it by the first stage yoke, away from heat and direct sunlight. When storing it for an extended period of time, select a dry cool, clean place, and apply to the hose and first stage silicone spray approved for use with diving equipment. CHECK-UP AND REPAIRS Regulator will provide optimum performance only if used properly and inspected regularly. Normal wear parts such as diaphragm, seat, exhaust valve, o rings, mouthpiece must be inspected and changed regularly. Every year, preferably before the start of the diving season, the regulator must be taken to a Dive System authorized technician for annual service. 5

Technical specifications All Dive System regulators meet the European standard EN 250-2000 (Air) or EN 13949-2004 (Nitrox). Specifications: DIN 300 bars - 4400 psi (Réf. : 316 060) I Stage CLV The balanced diaphragm first stage reduces the high pressure air in the cylinder to an adjustable intermediate pressure of 9,5 bars (145 PSI) above ambient pressure. The first stage is balanced and delivers air at constant pressure even as the pressure decrease inside the cylinder. A low pressure hose links the first to the second stage. The first stage features four 3/8 LP ports and two 7/16 HP ports. II Stage X-TECH The second stage is a pneumatically balanced second stage, witch offers optimum ease of breathing. An additional adjustment allow the diver to fine tune the Venturi effect to the dive / diver conditions. A specially designed front cover offers maximum protection to the diaphragm and minimizes the side effect of strong currents. The second stage come from factory with adjustment knob and lever in the minus position. Venturi lever Located on the side of the second stage Housing, enables the diver to control the inhalation Venturi effect. When on the + position, the diver get maximum Venturi assistance upon initial inhalation, the air flow is maintained without additional effort. Important: On the surface to avoid any free flow resulting from surface waves and / or sudden entry in the water, the diver should keep the lever pushed towards the front in the - minus position. This position should be maintained whenever the second stage is used as an octopus for a safe second stage. At the beginning of the dive, the diver should push the Venturi lever in the + / plus position, to obtain optimum breathing characteristics. The + / plus position is the dive mode position. 6

Inhalation Resistance This knob, located on the left hand side of the hosing, allows to adjust the resistance on the spring and thereby to alter the initial breathing resistance. The diver can choose any position between the minimum (turned completely counter clock wise) and the maximum (turned completely clock wise) depending on the conditions. turning the knob clockwise will increase the inhalation resistance, turning it counter clockwise will decrease the inhalation resistance. When the inhalation resistance knob is in the minimum position, there may be a light free flow. If this is the case, slightly turn the knob clockwise until the air flow stops. Orhave your regulator checked by an authorized Dive System dealer. Note The first stage 3/8 LP ports can accommodate the safe second stage octopus and the buoyancy compensator LP hose and / or drysuit inflator hose. On the 7/16 HP port, install a pressure gauge to check air supply during the dive. Venturi lever Inhalation Resistance 7

COLD WATER USE Use of regulators in water temperature colder than 50 F / 10 C, requires special equipment and precautions. The X-TECH CLV should be used in cold water diving. Make sure that your air supply meet the EN 12021 quality norm requirements. Use a cylinder with a dual outlet Y-valve and two independent breathing system outfitted for cold water use. Do not expose the regulator to cold air (colder than 32 F / 10 C). Place the regulator first stage in the cold water to bring its temperature up before use. Do not purge the second stage outside the water to avoid freezing incidence. During the dive : do not purge unnecessary demands on your regulator, i.e. avoid using all at once the regulator, the octopus, the BC power inflator and the dry-suit valve. Do not purge the regulator unless required. If the regulator were to freeze up accidentally and therefore free flow, switch to your second breathing system and abort the dive. WARNING Cold water diving requires special equipment and training. Failure to follow the above instructions and recommendations can result in serious injury or death. Certified instruction should be received and completed for cold water and ice diving from a certified instructor by a recognized training agency prior to attempting any cold water or ice diving. 8

Warranty All our products are guaranteed according to the current laws in the country of purchase from the date of purchase by the user, in compliance with the use it was developped for. The warranty covers parts recognized as defective by our technical services, and manufacturing and material defects with the exception of parts worn by use. The warranty does not cover damages caused by rough handling, dropping, or incorrect use at the surface or while diving. The warranty does not cover defects in appearance or function that are due to normal wear of the product or to its ageing. The warranty shall not be valid if the product was not cared for or used as stipulated in the user guide or if the product was opened or maintenanced by a person lacking adequate technical training and not using the proper maintenance equipment. The responsibility resulting from the sale of our products is limited exclusively to the above warranty and excludes all possibility of recourse to penalties or damages. To benefit from the present warranty, the product must be returned along with proof of purchase. 9