MT The secret of harmonious breathing BABYLOG 8000 PLUS

Similar documents
MT Excellent performance and reliability EVITA 4 EDITION

Better to have one OXYLOG 3000

Transport ventilation without compromise DRÄGER OXYLOG 3000 PLUS

D Transport ventilation without compromise DRÄGER OXYLOG 3000 PLUS

Dräger Savina Sub-Acute Care Ventilation

D Designed for non-invasive ventilation DRÄGER CARINA

Focused on essentials DRÄGER SAVINA 300

Made to meet your needs DRÄGER SAVINA 300

Oxylog 2000 plus Emergency & Transport Ventilation

D Rising up to the challenge OXYLOG 3000 PLUS

D Reliability goes XL

D Accessories that actively cooperate DRÄGER INFINITY ID-ACCESSORIES

D Beyond essentials DRÄGER SAVINA 300 SELECT

Setting new trends in ventilation. DRÄGER EVITA INFINITY V500

Dräger ABIL-L Airline Equipment

MT Your customized anesthesia workstation DRÄGER FABIUS GS PREMIUM. Dräger. Technology for Life

Resuscitaire Neonatal Open Care

Primus Anaesthesia Workstations

D The plus that makes all the difference DRÄGER FABIUS PLUS

Dräger Pendula Medical Supply Units

Dräger MSI P7 Combustion Gas Analysis

Dräger Savina 300 Classic ICU Ventilation and Respiratory Monitoring

D The specialist for every environment DRÄGER FABIUS TIRO

Dräger PA91 plus Standard and PA91 plus Marine Self Contained Breathing Apparatus

D The plus that gives you more DRÄGER FABIUS PLUS

Oxylog VE300 Emergency & Transport Ventilation

Dräger Short-term Tubes Dräger-Tubes

D Your personal anesthesia assistant DRÄGER PRIMUS. Dräger. Technology for Life

Dräger Carina Sub-Acute Care Ventilation

Dräger Oxylog 3000 plus Emergency & Transport Ventilation

Evita 2 dura. First-class ventilation in your patient s best interests. Because you care. Emergency Care OR/Anesthesia Critical Care Home Care

Dräger PAS Micro Short Term Breathing Apparatus

Dräger CAPITANO 140 Mobile Compressor

Oxylog 2000 plus. Step up your performance. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Dräger CPS 6900 Gas-Tight Suit

Dräger-Tube pump accuro Dräger Tube Pump

Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring

Dräger OCEANUS 140 Mobile Compressor

Dräger coaxial breathing circuits Consumables and Accessories

Dräger X-plore 6300 Full-Face Mask

Dräger Bodyguard 7000 Warning Device

D Beyond essentials DRÄGER SAVINA 300 SELECT

Dräger Carina Sub-Acute Care Ventilation

Dräger X-plore 3500 Half Mask

O 2 Star - Oxygen Therapy Accessories Consumables and Accessories

MT Increase patient comfort and therapeutic benefits Dedicated accessories for Carina ventilator CARINA

Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring

Dräger Compressed Air Breathing Cylinders Accessories for Breathing Apparatus

Dräger RZ 7000 Test Equipment

Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring

Focused on essentials DRÄGER SAVINA 300

Dräger Fabius GS premium Anaesthesia Workstations

D Quality and Precision you can Trust in Oxygen Administration CONVENTIONAL FLOWMETER DIGITAL FLOWMETER COMPACT FLOWMETER

Dräger PAS AirPack 1 Compressed Air Breathing Apparatus

Dräger Bodyguard 1500 Warning Device

Mechanical Ventilation

DL D juis Every breath is vital Dräger Gas Management Systems for hospitals

GE Healthcare. Centiva/5 Critical Care Ventilator. Meet a new level of expectations

Monnal T60. Touch and Breathe.

Redefining Anaesthesia DRÄGER ZEUS INFINITY EMPOWERED

Dräger Quaestor 7000 Test Equipment

Aquacom Diving Equipment

Dräger Fabius plus XL Anaesthesia Workstations

Fabius plus. The plus that makes all the difference. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

HAMILTON-C2 HAMILTON-C2. The universal ventilation solution

Dräger Fabius Tiro Anaesthesia Workstations

Dräger X-pect 8500 Goggles Protective Eyewear

Dräger X-plore 5500 Full Face Mask

Oxylog 3000 plus Emergency & Transport Ventilation

fabian Therapy evolution Our 2-in-1 device

Fabius plus. The plus that makes all the difference. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Dräger Tactical Harness Versatile carrying harness for LAR rebreathers.

Dräger ERS-Chamber Refuge Chambers

The Crossvent 2i+ 2. Ventilator Concept (brief theory of operation and features)

Dräger Bodyguard 1000 Warning Device

Dräger Babylog VN500 Neonatal Open Care

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

Dräger PAS AirPack 2 Compressed Air Breathing Apparatus

Dräger NITROX 200 Diving Equipment

Evita 2 dura. High-end ventilation in your patient s best interests. Because you care

Filtering Escape Hoods

VentStar Oxylog Breathing Systems Consumables and Accessories

Training Benzene Awareness. Basic Information

VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE

Dräger SPC 3700 with CVA 0700 Splash Suit and Vest

HAMILTON-C3 HAMILTON-C3. The compact high-end ventilator

SLE5000 Infant Ventilator with HFO

Fabius Tiro TM. Designed for your environment. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

PERFORMANCE EVALUATION #34 NAME: 7200 Ventilator Set Up DATE: INSTRUCTOR:

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters

Dräger PARAT 3160 Filter Escape Device

D Make the golden hour your time to shine. RESUSCITAIRE

Mechanical ven3la3on. Neonatal Mechanical Ven3la3on. Mechanical ven3la3on. Mechanical ven3la3on. Mechanical ven3la3on 8/25/11. What we need to do"

EvitaXL. Excellence throughout the ventilation process. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

fabian HFO: Modular, Powerful, Versatile.

Dräger WorkMaster Industry Gas-Tight Suit

VENTILATION SERVO-i INSPIRATION IN EVERY BREATH

Anesthesia Workstation

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

A9600 Anesthesia Workstation. Your healthcare, we care.

Transcription:

MT-1166-2005 The secret of harmonious breathing BABYLOG 8000 PLUS

02 The product of expertise and experience More than 30 years of experience in neonatal ventilation and a century of expertise in breathing technology have gone into Dräger Medical s Babylog 8000 plus. The result is a neonatal ventilator that satisfies the extremely high standards you set in caring for your little patients. Little patients, great demands Artificial respiration is one of the most invasive procedures performed in neonatal intensive care. So it is particularly important that a ventilator adapts to your little patient s requirements, and not vice versa. The ultimate aim is to achieve a harmonious balance between patient and ventilator where the ventilator not only adapts to the patient s needs but also protects the baby as much as possible from serious sideeffects such as volutrauma or atelectasis. Another major consideration from the moment ventilation begins is how to wean the baby off the ventilator. Here, the right balance is just as important. Weaning is enhanced through sensitive synchronization with spontaneous breathing, which in practice means adapting to interferences such as tube leaks while allowing the baby the maximum room to breathe. MT-3686-2003

03 milestones in ventilation MT-952-2004 MT-1056-2004 Inner qualities not external trappings For decades Dräger Medical has been supplying ground-breaking neonatal ven tilators. Classic devices that have pro ved how invaluable they are thousands of times over in locations all around the world. The Babylog 8000 plus is no exception. Its qualities are not confined to functional form, clever design or any other external trappings. The Babylog 8000 plus stands for milestones in neonatal ventilation inner qualities your little patient will benefit from. The optional Pressure Support and Volume Guarantee functions, for example, bring a new dimension to ventilation therapy and facilitate the pro cess of weaning a baby off the venti lator. Both features contribute to this ventilator s most valuable asset its ability to promote harmonious breathing.

04 little patients, great demands The advantages of optimum ventilation If you use a Babylog 8000 plus, you can rest assured you re giving the little patient in your care the best possible ventilation. Whatever mode you require CPAP, IMV, triggered modes such as SIMV, SIPPV, Pressure Support Ventilation or Volume Guarantee the Babylog 8000 plus meets the demands. SIMV and SIPPV a new generation These well known synchronized ventilation modes have been optimized in the Babylog 8000 plus: A unique automatic leakage adaptation ensures sensitive and exact synchronization with the patient s inspiration even in the event of changing tube leaks. Work of breathing is minimized and the need to manually adjust a trigger sensitivity has become a thing of the past. Pressure Support Ventilation the leak adapted pressure support for neonates Pressure Support Ventilation (PSV) allows the infant more control over the respiratory pattern with synchronization at the end of inspiration, not just the beginning. It maintains the optimal inspi ra tory time for a given patient at a given time and automatically adjusts to changes in time constants. The inspiratory hold is eliminated and the chance of active expiration against positive pressure is minimized. PSV allows the infant to breath as needed with pressure support being given throughout the breath. This is important in the prevention of atelectasis. PSV is a time cycled, pressure limited, synchronized mode with each spontaneous breath supported like in SIPPV. A backup rate is set to maintain adequate support in case of apnea. The selected support pressure enables you to transfer the work of breathing from the ventilator to the patient and thus provide endurance training and shorten weaning time. Inspiration is ended when inspiratory flow declines to 15% of peak flow. A unique automatic leakage adaptation ensures sensitive and exact synchronization with the patient s inspiration and expiration even in the event of changing tube leaks. Leak adapted pressure support the pressure support for neonates! PSV - leak adapted syn chro ni zation with the patient s inspiration and expiration. Example: The set Ti is 0.5 seconds to allow the patient to breath. The actual Inspiration time is 0.3 seconds and will adapt to changes in time constants. VG - delivery of consistent tidal volumes at lowest possible airway pressure. Example: The set Pinsp is 20 mbar. The actual Peak pressure is 15 mbar, because this is sufficient to deliver the set Vt of 5.5 ml.

05 D-9260-2009 344-97 Consistent Volume Guarantee Pressure-controlled ventilation with continuous flow is now the standard in neonatal ventilation. Over the last few years, however, the measurement of tidal and minute volumes has also become an integral part of ventilation monitoring. Here, the goal is to ensure effective ventilation with a sufficient tidal volume while at the same time avoiding volutrauma. The Volume Guarantee (VG) provided by the Babylog 8000 plus combines the advantages of pressure-controlled ventilation while maintaining consistant tidal volumes. By continuing to ventilate with pressure control in SIMV, SIPPV or PSV modes, the Babylog 8000 plus delivers the tidal volume preset with the VG function. This prevents overdistention and volutrauma due to surfactant treatment and other sudden changes of compliance or resistance. The peak airway pressure deployed by the ventilator varies between the clinician-set Pinsp and PEEP. During weaning the pressure level is automatically lowered, a variable spontaneous respiratory drive is compensated. The sophisticated software algorithm of the Volume Guarantee function is based on exhaled tidal volumes, therefore compensating for changing tube leakages. VG enhances your therapeutic possibilities and facilitates the weaning process. Advantageous BabyFlow nasal CPAP The BabyFlow nasal CPAP system designed for use with Babylog 8000 plus is easy to apply and supplies stable CPAP at low operating costs and minimal noise through the use of standard patient tubing and reusable parts. Its unique prong and mask design andinnovative fixation accessories are designed to reduce the trauma asso ciated with the delivery of nasal CPAP. High Frequency Ventilation Despite the most sophisticated conventional ventilation strategy, there are a few situations that require a different approach. For such patients the Babylog 8000 plus offers the alternative of High Frequency Ventilation (HFV), which can be switched on at the touch of a button. This mode is fully integrated and can be run under CPAP or in combination with IMV. Even the tiny tidal volumes during HFV can be reliably measured and taken into account to fine-tune your settings. The HFV mode effectively removes CO2, which can be closely monitored using the DCO2 value.

06 intelligent operating concept The benefits of ergonomic design An operating concept that is oriented to your needs as a user and a tailored mo nitoring system serve to optimize ventilation. This frees you from many onerous tasks usually associated with device operation so you can spend more time concentrating on your little patient. Intelligent operating concept All key settings can be adjusted using just six rotary knobs with clear and accurate scaling. The integrated, high-contrast display shows you settings, measured values, trends and real-time curves and allows you to accurately fine-tune all parameters. LEDs and plain-text messages guide you on the ventilation mode currently in use. Intelligent alarms classified by priority inform you with plain-text messages of any problems and their causes so troubleshooting is easier and quicker. A log book stores up to 100 alarms, warnings and advisory messages giving time and date details so you can accurately carry out a post-analysis of any situation. Ergonomics in action. Precision ventilation monitoring All key ventilation parameters are displayed and monitored by intelligent alarms. Alarm limits for pressures and oxygen concentration are automatically set and adjusted when settings are changed. Daily calibration of the oxygen cell also takes place automatically again leaving you more time for your little patient. The Babylog 8000 plus also provides you with graphic representations of pressure and flow curves as well as trends for the main ventilation parameters. Integrated lung function monitoring extends your diagnostic possibilities without the need for additional equipment. For each special ventilation mode offered the Babylog 8000 plus also has the special monitoring required. Sound economics The Babylog 8000 plus is an impressive operator in economic terms, so hospital administrators will be just as pleased with its running costs as you are with its performance. The modern operating concept and extensive documentation reduce the amount of initial training needed, gas-saving pneumatics minimizes oxygen consumption, and the integrated device software and modular design save time and money in service and maintenance.

07 MT-955-2004 MT-940-2004 Safe investment The Babylog 8000 plus is a safe investment now and in the future because its future-oriented design enables new modes of ventilation to be retrofitted as they become available. This ventilator is also an efficient communicator with its hospital environment. When equipped with the BabyLink upgrade, the Babylog 8000 plus is an open system with three output channels (two analog, one digital) and a serial interface so there are no limits on the possibilities of on-going data processing whether for documentation, monitoring or research purposes. MT-750-2002

HEADQUARTERS Drägerwerk AG & Co. KGaA Moislinger Allee 53 55 23558 Lübeck, Germany www.draeger.com REGION EUROPE CENTRAL AND EUROPE NORTH Dräger Medical GmbH Moislinger Allee 53 55 23558 Lübeck, Germany Tel +49 451 882 0 Fax +49 451 882 2080 info@draeger.com REGION EUROPE SOUTH Dräger Médical S.A.S. Parc de Haute Technologie d Antony 2 25, rue Georges Besse 92182 Antony Cedex, France Tel +33146115600 Fax +33 1 40 96 97 20 dlmfr-contact@draeger.com REGION MIDDLE EAST, AFRICA, CENTRAL AND SOUTH AMERICA Dräger Medical GmbH Branch Office Dubai Dubai Healthcare City P.O. Box 505108 Dubai, United Arab Emirates Tel + 971 436 24 762 Fax + 971 436 24 761 contactuae@draeger.com REGION ASIA / PACIFIC Draeger Medical South East Asia Pte Ltd 25 International Business Park #04-27/29 German Centre Singapore 609916, Singapore Tel +65 6572 4388 Fax +65 6572 4399 asia.pacific@draeger.com Manufacturer: Dräger Medical GmbH 23542 Lübeck, Germany The quality management system at Dräger Medical GmbH is certified according to ISO 13485, ISO 9001 and Annex II.3 of Directive 93/42/EEC (Medical devices). 90 48 592 04.11-5 Marketing Communications PR LE Printed in Germany Chlorine-free environmentally compatible Subject to modifications 2011 Drägerwerk AG & Co. KGaA