PCDY01 Dissolved Oxygen Meter

Similar documents
No.600,No.21 Supmea Automation Co.,Ltd. Vortex flow meter. Datasheet DY2900

PC12K Flush Diaphragm Pressure Sensor with Clamp

PC10 Piezoresistive Silicon Pressure Sensor

Oxymax COS61/COS61D. Technical Information

Triton DO8 Dissolved Oxygen Sensors ELECTRO-CHEMICAL DEVICES

Oxymax W COS41. Technical Information. Potentiostatic amperometric two-electrode sensor Long-term stable sensor for water and wastewater applications

Optical Dissolved Oxygen Meter

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

Oxymax W COS51D. Technical Information. Digital sensor for measuring dissolved oxygen Membrane-covered amperometric sensor

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

BI-680 Online Dissolved Oxygen Controller Instruction Manual

陕西创威科技有限公司. Shaanxi Creat Wit Technology Co., Ltd. Precision pressure calibrator-cwy300 Operating Manual

Optical Dissolved Oxygen Meter

COM280. Technical Information. Oxygen measurement Battery-driven pocket meter for dissolved oxygen measurement

BUBBLER CONTROL SYSTEM

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

Oxymax H COS21. Technical Information. Sensor with long-term stability for frequent sterilization and autoclaving

SAPCON. User Manual. Capacitance Continuous Level Indicator. . Introduction. . General Description. . Principle of Operation. .

analytical bulk flow distance FLOW level pressure temperature industrial communication

Dissolved Oxygen and measurement possibilities. Berno Lüpkes, 15 th March 2017

Features. Description

BUBBLER CONTROL SYSTEM

dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO)

Coriolis Mass Flow Meter

Integral type Differential pressure flowmeter VNT Series

Instruction Manual. PLT Series. 1. General Specification. 2. Installation. 3. Wiring. 4. Function. 5. Setting & Calibration

GasSense NDIR User Manual

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

628 Differential Pressure Decay Leak Tester

ACV-10 Automatic Control Valve

Instruments for Measurement of Dissolved CO 2 and O 2 in Beverages

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Pressure transmitter PASCAL Ci4

JUMO dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO)

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

Programmable pressure and temperature transmitters PTM/RS485

LUGB Vortex Flowmeter

Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing

OC508 Programmable mv Calibrator

Heavy Duty Dissolved Oxygen Meter

Instruction Manual Differential Pressure Transmitter

Parametrable / Programmable Pressure Transmitter

HumiSys HF High Flow RH Generator

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres

Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values. Operations Manual

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

Programmable pressure and temperature transmitters PTM/RS485

Model 601CV. Mass Flow Controller. Product Features:

INSTRUCTION MANUAL. FLOAT TYPE LEVEL TRANSMITTER HT-100R Series HITROL CO., LTD.

780S Ultra High Purity Series

D-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA

Programmable Submersible Level Transmitters

SCAM T.P.E. WATER TREATMENT SYSTEM SWT- AP AUTOMATIC PURGE

MPM426W/436W Submersible Level Transmitter

FLUORESCENCE DETERMINATION OF OXYGEN

OxiQuant S. Operating Instructions

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

Carbo Online CO 2 Analyzer for Beverages. ::: Great People Great Instruments

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring.

COSMO INSTRUMENTS CO., LTD.

CCT-7320/ROC-2313 Reverse Osmosis Controller

INSTRUCTION MANUAL. 840 Transmitter. Loop Powered Dissolved Oxygen Transmitter

C-Flow Coriolis Mass Flow Meters

FTS SUBMERSIBLE PRESSURE TRANSMITTER USER S MANUAL

TEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

Model GFC 7000T CO 2 Analyzer (Addendum to GFC 7000TA Manual, PN 07272)

Dissolved Oxygen OPERATING INSTRUCTIONS

Digital Indicating Dissolved Oxygen Meter AER-102-DO. Instruction Manual

D-Opto Dissolved Oxygen Sensor Operation Manual

CCS240 and CCS241. Technical Information. Sensors for chlorine dioxide Amperometric, membrane-covered sensors for installation in the CCA250 assembly

Oxygen Meter User Manual

D-Opto. Dissolved Oxygen Sensor. Operation Manual (Software Version 1.0)

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

TH-1800-T TRX-700-CNG Converter

For Multi-Parameter Meters see mvx

Pneumatic high-pressure controller Model CPC7000

Columbus Instruments

Visualize Nitrogen Gas Consumption

Stand-Alone Bubble Detection System

PRELIMINARY DATASHEET

Pressure Sensitive Paint (PSP) / Temperature Sensitive Paint (TSP) Part 1

Operating manual. Oxi 3205 O mg/l C. [Sal] Dissolved oxygen (D.O.) meter

Membrane covered optical CO 2 sensor

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

For Multi-Parameter Meters see mvx

Additel 761 Automated Pressure Calibrators

Sensoric 4-20 ma Transmitter Board Operation Manual

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

D i s s o l v e d O x y g e n M e a s u r e m e n t

Transmitter CS 21 Operation Manual

Electrochemical Sensor

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

High-performance submersible pressure transmitter For level measurement Model LH-20

NOVATECH OXYGEN /CARBON DIOXIDE ANALYSER /TRANSMITTER MODEL 1537

SCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel. DTLS Manual

High-performance submersible pressure transmitter For level measurement Model LH-10

Dissolved Oxygen Guide

Transcription:

PCDY01 Dissolved Oxygen Meter Features Support dissolved oxygen(do), saturation(sat), oxygen partial pressure(opp) and temperature measure. Support upper/lower limit control, transmitting output, RS485 communication. Configurable manual and auto temperature offset function. Configurable upper/lower limit alarm and delay. Configurable hummer and LCD backlight switch. Optional language, Chinese and English. Zero oxygen and full-scale calibration. Applications Sewage treatment plants: Oxygen measurement and regulation in the activated sludge basin for a highly efficient biological cleaning process Environmental protection water monitoring: Oxygen measurement in rivers, lakes or seas as an indicator of the water quality Water treatment: Oxygen measurement for status monitoring of drinking water for example (oxygen enrichment, corrosion protection etc.) Fish farming: Oxygen measurement and regulation for optimum living and growth conditions Product overview PCDY01 dissolved oxygen online analyzer is an intelligent online chemical analyzer. The cap of the sensor is coated with a luminescent material. Blue light from an LED illuminates the luminescent chemical. The luminescent chemical instantly becomes excited and releases red light. The time and intensity of red light are inversely proportional to the concentration of oxygen molecules, So the concentration of oxygen molecules is calculated. 1 www.wtsensor.com

Measuring principle Sensor design: Oxygen-sensitive molecules (markers) are integrated in an optically active layer (fluorescence layer). The surface of the fluorescence layer is in contact with the medium. The sensor optics are directed at the underside of the fluorescence layer. There is an equilibrium between the oxygen partial pressure in the medium and that in the fluorescence layer: If the sensor is immersed in the medium, the equilibrium is established very quickly. Measuring process: The sensor optics send green light pulses to the fluorescence layer. The Oxygen-sensitive molecules instantly becomes excited and releases red light. The duration and intensity of the response signals is directly dependent on the oxygen contents and the partial pressure. If the medium is free from oxygen, the response signals are long and very intense. Oxygen molecules quench the Oxygen-sensitive molecules. As a result, the response signals are shorter and less intense. Measurement result: The sensor returns a signal that is in proportion to the oxygen concentration in the medium. The medium temperature and air pressure are already taken into account calculated in the sensor. In addition to the standard values of concentration, saturation index and partial pressure, the sensor also returns a raw measured value in μs. The value corresponds to the decay time of the fluorescence and is approx. 20 μs in air and approx. 60 μs in media free from oxygen. Technical specifications Measurement variables Measuring range Resolution Accuracy Repetition Temperature measurement type Auto A/manual H Measuring range Output type Max.loop resistance Accuracy Output type Communication protocol Power supply Alarm relay Dissolved oxygen, saturation, oxygen partial pressure 0-20mg/L,0-200%,0-400hPa 0.01mg/L,0.1%,1hPa ±1.5%FS ±0.5%FS NTC 10K/PT1000-10 - 60 Resolution: 0.1 Correction accuracy: ±0.5 4-20mA current transmission output 750Ω 0.1%FS RS485 digital signal output Standard MODBUS-RTU (customizable) AC220V±10%, 50Hz/60Hz (optional 24V±10%) AC250V, 3A 2 www.wtsensor.com

Installation method 1 Dissolved oxygen transmitter Open a 92.5 * 92.5(mm) installation hole on the instrument cabinet or installation panel (the dimension is 100*100*150mm). Insert the instrument into the installation hole and latch on the butterfly clasp, as shown below. 2 Dissolved oxygen sensor 3 www.wtsensor.com

Identification of terminal Wiring diagram +12VDC: Power supply of dissolved oxygen electrode AGND: Power negative of dissolved oxygen electrode RS485-A: Dissolved oxygen electrode communication-a RS485-B: Dissolved oxygen electrode communication-b NC: Null RS485(A+): RS485 communication interface A+ Optical Dissolved Oxygen Online Analyzer Operation Manual RS485(B-): RS485 communication interface B- I(+):4-20mA output port + I(-): 4-20mA output port HO: High alarm of normal open relay HC: High alarm of normal close relay COM: Common port LO: Low alarm of normal open relay LC: Low alarm of normal close relay COM: Common port 220V L: AC220V fire wire NC: Null 220V N: AC220V zero wire Wotian reserves the right to make any change in this publication without notice. The information provided is believed to be accurate and reliable as of this product sheet. 4 www.wtsensor.com

Contact us Nanjing Wotian Technology Co.,Ltd. Add: 5 Wenying Road, Binjiang Development Zone, Nanjing, 211161, China Sales Manager: Wuzhou Lian Anshan Wotian Sensor Corp. (Branch Factory) Add: 262, Yueling Road, Gaoxin District, Anshan, China MP: 0086-13998828452 Email: lianwuzhou@wtsensorus.com American Company German Company Korean Company Wotian Sensor Corporation Wotian Sensor GmbH Korea Wotian Technology Co., Ltd. Sales Manager: Geoffery Gao Sales Manager: Frances Sales Manager: Yinji An MP: 001-626 808 1707 MP: 0086-13478122009 E-mail: geoffery@wtsensorus.com E-mail: frances@wtsensorus.com E-mail: anyinji@wtsensorus.com V1.0 5 www.wtsensor.com