Model DPC3500 Continuous Low Range Dew Point Analyzer. Operations Manual

Similar documents
Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values. Operations Manual

DP2000 Portable Dew Point Analyzer Operations Manual. Model DP 2000 Portable Digital Dew Point Analyzer OPERATIONS MANUAL

eflo ELECTRONIC GAS FLOW METER OPERATIONS MANUAL

DPC-30 DPC-100. Reference Manual

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

RAM 4021-DPX Operation Manual

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM Operation Manual

RAM 4021 Operation Manual

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

EASIDEW TRANSMITTER with Current Source Output

RGC-IR Remote Gas Calibrator for IR400

CSA Sample Draw Aspirator Adapter Operator s Manual

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

PURA. Pure Gas Dewpoint Transmitter. Users Guide

Installation, Operation and Maintenance Manual. TSV Temperature Shut-off Valve SPD Rev. 6 10/07

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

BGA244 Binary Gas Analyzer

GAS FUEL VALVE FORM AGV5 OM 8-03

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

RK-IR Sample Draw Aspirator Adapter Operator s Manual

MAGNA-CHEM AUTOMATIC CHLORINATOR - MODEL: CSA-2P MAGNA ORP Chlorine Pump

Marschalk Model # 94000

GASGUARD VENT LINE3 Ammonia Sensor OPERATING & INSTALLATION MANUAL

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

Brooks Flow Controllers for Gas and Liquid Service Model FC 8744, Series FC 8800 and 8900

Operation Manual. O2 Quickstick. Oxygen Analyzer 08.17

RK LEL Sample Draw Aspirator Adapter Operator s Manual

GG-VL2-NH3 AMMONIA VENT LINE SENSOR. Installation and Operation Manual

NOVALYNX CORPORATION MODEL WEATHER STATION INSTRUCTION MANUAL

Oxygen Concentrator. Installation and Operation Manual. ClearWater Tech, LLC. Integrated Ozone Systems

In Vivo Scientific, LLC INSTRUCTION MANUAL

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL -

E X R A D I N Spherical Ion Chambers A3. A4 REF DOC #

Advanced Test Equipment Rentals ATEC (2832)

Operation Manual. Pro CO. Carbon Monoxide Analyzer. Rev

Title: Standard Operating Procedure for R&R Environmental Devices Model MFC201 Gas Dilution Calibrator

AMT-Ex Dewpoint Transmitter

YOU MUST READ THIS MANUAL BEFORE USE

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

Handi+ OPERATING MANUAL & INSTRUCTIONS FOR USE. R218P15 Industrial. R218M15 Rev. D

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports

with O 2 Controller Instruction Manual

MZA 6010 Multi-Zone, Multi-Gas IR Analyzer (CO, CO 2, and CH 4 Gas Analyzer with % Carbon Calculation and Optional H 2 Measurement) Operations Manual

Digital Vacuum Regulator

Operation Manual. Pro CO Analyzer TM. Pro CO with High Temp Alarm Carbon Monoxide Analyzer

TECHNICAL INFORMATION

HAI UPB 15A Relay Switch and Auxiliary Switch Installation and Operating Instructions

Section 3- Repair and Calibration Procedures

5 Channel Calibrator

PRODUCT SUPPORT MANUAL YACHT BEAM 6M Searchlight Remote Control System with Joystick Remote Control Panel

User s Guide Temperature Sensor Converter TSC-599

The Ins and Outs of I/P Transducers

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

92831 TEL: (714) FAX:

DIGIVAC 22W Series INSTRUCTION MANUAL. Wide Range Linearized Vacuum Transmitter and Controller YOU MUST READ THIS MANUAL BEFORE USE

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

AUTO PUMP STATUS CENTER

PM105 PRESSURE METER USER S MANUAL

D10S/D20S Wall/Post Mount Inflator Quick Start Manual

DTG - LCD Digital Temperature Gauge USER MANUAL

55 Series. 55 Series REMOTE MOUNTING TEMPERATURE SWITCH AND CONTROL FEATURES. Single or Dual 15 A Switch Output. Panel or Surface Mount

Operation Manual. O2 Quickstick. Oxygen Analyzer

HI 2314 HI 2315 HI 23151

92831 TEL: (714) FAX:

Operation Manual. Pro He Alarm TM. Helium Analyzer. Rev 08.17

Instruction Manual BA90 Precision Barometer

MODEL GENERA PURGE TURBINE INSTR DANGER HIGHLY TOXIC AND OR FLAMMABLE LIQUIDS OR GASES MAY BE PRESENT IN THIS MONITORING SYSTEM.

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

T EK-SUB 4800C 19 mm Submersible Level Transmitter

OWNER S MANUAL NMB SERIES

Model PDT Dewpoint Transmitter

HLM-2000-TX Gas Transmitter User Manual

SPS-5. Rate Computing Scale. Operation Manual

BI-680 Online Dissolved Oxygen Controller Instruction Manual

Overview. Front Panel: Keypad and Display

OEM Manual. MODEL ½ Digit DRUM SCALE

Operation Manual. Pro CO 2 Analyzer. Carbon Dioxide Analyzer. Rev

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

Electro-Pneumatic Converter YT-940 SERIES

WSN: XXXXXX 101 ROME COURT FORT COLLINS, CO, PHONE #: (970) FAX #: (970) TO-Clean Manual

INSTRUCTIONS FOR MODEL SG6500 GAS HEATERS

Sterile Visual Flow Indicator

453 Series Steam Heated Vaporizing Regulator

AND OPERATION INSTRUCTIONS

Operating Instructions

PurgEx. X Purge Controller N Version. User s Manual

Model Series 62 Constant Differential Relay

OX SCFH Oxygen Concentrator. Installation and Operation Manual

ENVIRONMENTAL INSTRUMENTS, LLC

210 Series Transmitter with External Electrochemical Sensor

INSTRUCTION MANUAL GAS TRAK

Model 106 DPI "Micro-switch" Installation and Operating Instructions

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

R E D I C O N T R O L S

BUBBLER CONTROL SYSTEM

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

D10 Inflator Quick Start Manual

Transcription:

Model DPC3500 Continuous Low Range Dew Point Analyzer Operations Manual Please read, understand, and follow these instructions before operating this equipment. Super Systems, Inc. is not responsible for damages incurred due to a failure to comply with these instructions. If at any time there are questions regarding the proper use of this analyzer, please contact us at 513-772-0060 for assistance.

Super Systems Inc. USA Office Corporate Headquarters: 7205 Edington Drive Shipping Address: 7245 Edington Drive Cincinnati, OH 45249 Phone: (513) 772-0060 http://www.supersystems.com Super Systems Europe Unit E TyburnTrading Estate, Ashold Farm Road B24 9QG Birmingham UNITED KINGDOM Phone: +44 (0) 121 306 5180 http://www.supersystemseurope.com Super Systems México Sistemas Superiores Integrales S de RL de CV Calle 3 Int.: 11. Zona Ind. Benito Juarez Querétaro, Qro. Méx. C.P.: 76120 Phone: +52 (442) 210 2459 http://www.supersystems.com.mx Super Systems China No. 335 XianXia Road Room 308 Shanghai, CHINA 200336 Phone: +86 21 5206 5701/2 http://www.supersystems.com Super Systems India Pvt. Ltd. A-26 Mezzanine Floor, FIEE Complex, Okhla Indl. Area, Phase 2 New Delhi, India 110 020 Phone: +91 11 41050097 Super Systems Inc. Page 2 of 9

Table of Contents Table of Contents... 3 Introduction... 4 Unpacking... 4 General Description... 4 Specifications... 4 Operation... 5 Startup... 5 Sample Cell Installation... 5 Sample Tubing Materials... 6 Calibration... 6 Wiring Connections... 6 Communications... 7 Replacement Parts... 7 Warranty... 8 Revision History... 9 Super Systems Inc. Page 3 of 9

Introduction Thank you for selecting Super Systems s DPC3500 as your Continuous Low Range Dew Point Analyzer. Please keep this manual in a secure place for future reference. Unpacking Carefully unpack the unit. The shipment should contain the following components: 1 Model DPC3500 12 x 10 x 6 Enclosure 1 Low Range Dew Point Sensor 20 Sensor Wire 1 Product Manual General Description The DPC3500 is designed to detect moisture content in gas samples from -148 F to +20 F (- 100 C to -7 C) dew point. The readings are remotely displayed in either Fahrenheit or Celsius on the door of the enclosure. In addition to the visual display, the DPC3500 also provides 4-20mA and RS232 outputs for data collection. The DPC3500 is designed to provide continuous readings. Response times are rapid as long as the sensor remains bathed in a sample gas stream that has a low dew point. If the sensor is allowed to reach ambient dew point (greater than 40 F or 4 C), it will take a considerable amount of time for it to achieve readings at the low level. When installed and operated properly, the Remote Mounting Assembly (supplied by SSi) will allow the sensor to be continuously exposed to a low-dew atmosphere, which will result in rapid response times. It is important to note that this analyzer is designed to measure dew point in gases that are noncorrosive. Some gases that can cause damage or failure to the sensor are trace amounts of SO 3, high concentrations of NH 3, Chlorine, HCL, and any other gases that could cause corrosion. If any of these components are missing or damaged, please contact SSi immediately at (513) 772-0060. Specifications Measurement Range -148 F to +20 F (-100 C to -7 C) Accuracy 75 F to +20 F ( 59 C to -7 C) +/- 1.8 F (+/- 1 C) Accuracy 148 F to 76 F ( 100 C to 60 C) +/- 3.6 F (+/- 2 C) Outputs 4 to 20 ma Display F or C Sensor Material Metalized Ceramic Sensor Guard 80µ Sintered Metal Guard Operating Pressure Vacuum to 5,000 PSIG Operating Temperature 40 F to +140 F ( 40 C to +60 C) Sample Flow Rate 10-15 SCFH Recommended Power Requirements 90 264 VAC Super Systems Inc. Page 4 of 9

Operation DPC3500 Operations Manual The DPC3500 s sensor is manufactured from a ceramic tile that is plated and vapor-deposited to form a surface that varies its electrical capacitance when exposed to small changes in water vapor pressure. This information, along with temperature readings from the tip of the sensor, is used by the microprocessor to determine dew point. The dew point of the gas in the sample line is displayed on the front panel. A switch to the right of the display toggles between showing the readings in degrees Fahrenheit and degrees Celsius. An indicator light to the right of the display will indicate the display s operating mode. Startup The DPC3500 was calibrated before it was shipped from Super Systems, Inc. After the unit is properly installed (see Wiring Connections and Sample Cell Installation ), power can be applied immediately. The flow meter on the Remote Mounting Assembly should be adjusted to provide approximately 5 to 10 SCFH of sample gas to the sensor. The rate of sample flow does not have any impact on the measured dew point, but a higher flow rate will result in a faster response time. At the time of installation, the sensor will be reading the ambient dew point. It will take between 3 and 6 hours of immersion in the sample stream for the unit to thoroughly dry out the sensor before it stabilizes at the correct readings. This delay is only at initial startup when the system is installed for the first time. The unit is intended to operate with a constant, steady stream of sample gas continuously bathing the sensor. This will prevent the sensor from absorbing moisture from ambient air, and will allow for continuous real-time monitoring of the sample stream. Sample Cell Installation For best results, the sensor should be mounted directly in the measured gas line. This will ensure that it remains in a low-dew atmosphere which will decrease the measurement response time. The sensor is fitted with 5/8-18 UNF Male threads. If the sensor is not going to be mounted directly in the gas stream, it should be installed in the Remote Mounting Assembly (SSi Part Number 13123), which can be purchased separately. Although this installation does allow for some design flexibility, it is important that only stainless steel tubing and fittings are used to carry the sample gas to the sensor. When installing the unit, verify that all fittings are tight, since any leaks will cause inaccurate readings. PN 13123 Remote Mounting Assembly During the operation of this unit, sample gas will constantly be flowing through the sensor and out of the vent. Depending upon the type of gas being sampled, appropriate safety precautions should be taken for proper venting of the sample gases after they exit the sampling assembly. In the event that a sample pump is required, it should be mounted after the sensor to not contaminate the sample prior to measurement. Super Systems Inc. Page 5 of 9

Sample Tubing Materials When determining the moisture content of gas samples, the materials used to transport the gas samples are extremely important. As the gas passes through tubing, the polarity of the moisture molecules will cause them to be attracted to the tubing. Any moisture that remains on the wall of the vessel does not have the opportunity to travel to the sensor, so it will reduce the sensor s response time. Also, some tubing materials (rubber, copper, PVC, etc.) are porous enough to allow for moisture penetration directly through the walls of the tubing, even in cases where there is considerable positive pressure. Super Systems, Inc. recommends that only stainless steel is used as the tubing material for measuring low dew points (below -50 F). It is also important to note that to maintain the integrity of the entire sampling system, all of the necessary valves and fittings, should also be constructed of stainless steel. These material precautions do not need to be followed downstream (after the sensor), since the moisture content of the gas at this point is unimportant. Calibration The calibration of the DPC3500 is traceable to National Institute of Standards and Technology (NIST) standards. Each sensor has a unique serial number, and the calibration data can be found on the Certification Sheet located at the back of this manual. Due to the sensitivity and complexity of the metalized ceramic moisture sensor, this unit cannot be user calibrated and must be returned to SSi for recalibration and recertification. It is recommended that the sensor be recalibrated every twelve months. Each sensor is interchangeable without the need for display recalibration, so only the sensor needs to be returned for recalibration, not the entire panel. Wiring Connections The power and communications wires for the sensor are connected to a plug that is attached to the head of the sensor. The wires will already be attached to this plug at SSi, however for reference the wiring for this plug is: Sensor Plug Terminal #1: Sensor Plug Terminal #2: Sensor Plug Terminal #3: Sensor Plug Terminal #4: Green Wire (to location #1291 on terminal strip) White Wire (to location #1281 on terminal strip) Red Wire (to location #1261 on terminal strip) Black Wire (to location #1271 on terminal strip) 20 feet of sensor wire are included with the unit; however, the unit is capable of operating over substantially longer distances if required. When attaching the necessary wires to the terminal strip inside the panel, all connections should be made according to the following diagram: Super Systems Inc. Page 6 of 9

1.0 AMP 1000 Line 1002 Neutral GND Ground SPARE N/A 1261 Red 1271 Black 1281 White 1291 Green 1331 Positive 1341 Negative 1361 Common 1371 Receive Data 1381 Transmit Data 120V 1 PHASE 60 HZ UNUSED FROM SENSOR CONNECTOR 4-20 ma OUTPUT RS 232 COMMUNICATIONS Communications The 4-20 ma output correlates to a dew point range of 148 F to 32 F ( 100 C to 0 C). Replacement Parts The following items can be purchased as needed for the unit. Part Number Description 13122 Factory Calibration & Re-Certification 13123 Sample Tubing Assembly 31413 Low Dew Point Sensor 31330 +15 VDC Power Supply Super Systems Inc. Page 7 of 9

Warranty Limited Warranty for Super Systems Products: The Limited Warranty applies to new Super Systems Inc. (SSI) products purchased direct from SSI or from an authorized SSI dealer by the original purchaser for normal use. SSI warrants that a covered product is free from defects in materials and workmanship, with the exceptions stated below. The limited warranty does not cover damage resulting from commercial use, misuse, accident, modification or alteration to hardware or software, tampering, unsuitable physical or operating environment beyond product specifications, improper maintenance, or failure caused by a product for which SSI is not responsible. There is no warranty of uninterrupted or error-free operation. There is no warranty for loss of data you must regularly back up the data stored on your product to a separate storage product. There is no warranty for product with removed or altered identification labels. SSI DOES NOT PROVIDE ANY OTHER WARRANTIES OF ANY KIND, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OR CONDITIONS OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. SOME JURISDICTIONS DO NOT ALLOW THE LIMITATION OF IMPLIED WARRANTIES, SO THIS LIMITATION MAY NOT APPLY TO YOU. SSI is not responsible for returning to you product which is not covered by this limited warranty. If you are having trouble with a product, before seeking limited warranty service, first follow the troubleshooting procedures that SSI or your authorized SSI dealer provides. SSI will replace the PRODUCT with a functionally equivalent replacement product, transportation prepaid after PRODUCT has been returned to SSI for testing and evaluation. SSI may replace your product with a product that was previously used, repaired and tested to meet SSI specifications. You receive title to the replaced product at delivery to carrier at SSI shipping point. You are responsible for importation of the replaced product, if applicable. SSI will not return the original product to you; therefore, you are responsible for moving data to another media before returning to SSI, if applicable. Data Recovery is not covered under this warranty and is not part of the warranty returns process. SSI warrants that the replaced products are covered for the remainder of the original product warranty or 90 days, whichever is greater. Super Systems Inc. Page 8 of 9

Revision History Rev. Description Date MCO# - Initial release 11-26-2001 A SSi address update, general update 04-14-2005 B Updated flow rate, fuse rating, and other 11-14-2005 modifications C Clarification to Sample Cell Installation 08-04-2015 2163 Update to description for PN 13123 D Adjusted flow rate and power requirements, added 01-24-2018 2228 sample pump mounting information E Adjust wire length in Unpacking section Super Systems Inc. Page 9 of 9