Pro-V Multivariable Flowmeter Model M22 In-line Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, Multivariable meter delivers mass flow, temperature, pressure, and density readings from a single installed device and reduces initial cost, installation cost and cost-of ownership over the lifetime of the instrument Mass flow equations - real gas, ideal gas, AGA 8, API 2540 Compensated mass flow reading of liquids, Energy Monitoring ability to compute and output energy use Easy to install and commission Reliable no moving parts, no fluid to sensor contact High accuracy with rangeability up to 100:1 Temperature up to 750 F Pressure up to 1500 psig Inline configuraton for pipes from 1/2-12 DN15 to DN 300 Field configurable ranges, outputs and displays Remote electronics option available for use in harsh environments or locations with limited access VorTek Instruments Pro-V multivariable flowmeters utilize three primary sensing elements a vortex shedding velocity sensor, an RTD temperature sensor, and a solid-state pressure transducer to measure the mass flow rate of gases, liquids and steam. Systems that use external process measurements to calculate mass flow may not provide adequate compensation for the fact that process conditions can change radically between the point of velocity measurement and the point where upstream or downstream pressure and temperature measurements are being made. Because the Pro-V multivariable flowmeter measures all of these parameters in a single location, it delivers a more accurate process measurement. Integrating multivariable output capability with a single line penetration also simplifies system complexity and helps reduce initial equipment cost, installation cost and maintenance costs. The product line is available with a wide range of options and meter configurations to meet your specific application requirements. 4-20mA loop powered Mass Meter design saves on energy costs HART protocol communications - Standard Modbus, BACnet communications available FM, FMC, ATEX, IECEx Approved VorTek Instruments, LLC 8475 West I-25 Frontage Rd., Suite 300 Longmont, CO 80504 USA Tel: 303/682-9999 Fax: 303/682-4368 info@vortekinst.com
Pro-V Principle of Operation Vortex flowmeters measure flows of liquid, gas and steam by detecting the frequency at which vortices are alternately shed from a bluff body. According to proven laws of physics, the frequency at which the vortices are alternately shed is directly proportional to the flow velocity. As flow passes a bluff body in the flow stream, the vortices create low and high pressure zones behind the bluff body, or shedder bar. The Pro-V M22 uses a piezoelectric crystal sensor to detect the pressure exerted by the vortices on the velocity sensor. The piezoelectric converts these pulses into electrical signals. The meter uses an all welded sensor design to create a robust sensor and to minimize potential leakages. VELOCITY SENSOR Performance Specifications A c c u r a c y Mass flow rate accuracy for gas and steam based on 50-100% of pressure range. Model M22 Multiparameter Inline Vortex Meter Process Variables Liquids Gas & Steam Volumetric ±.7% of Rate ± 1% of Rate Flow Rate Mass Flow Rate ± 1% of Rate ± 1.5% of Rate Temperature ± 2 F (± 1 C) ± 2 F (± 1 C) Pressure ±.3% of Full Scale ±.3% of Full Scale Density ±.3% of Reading ±.5% of Reading BLUFF BODY VORTICES R e p e a t a b i l i t y Volumetric Flow Rate......... ±.1% of rate Temperature................ ±.2 F (±.1 C) Pressure................... ±.05% of full scale FLOW Pro-V Model M22-VTP The Model M22-VTP offers you flow computer functionality in a compact field device. This multivariable instrument incorporates temperature and pressure sensors to provide an instantaneous reading of the compensated mass flow rate of gases, liquids and steam. In addition to outputs for totalized mass and alarm settings, the field-configurable electronics deliver up to three analog 4-20 ma outputs of five process measurements, including volumetric flow rate, mass flow rate, pressure, temperature and density. Pro-V Model M22-VT The Model M22-VT integrates a precision 1000 Ohm platinum RTD temperature sensor that can be used to calculate and output a compensated mass reading. This device is typically used to measure flow rates of saturated steam. Pro-V Model M22-V The Model M22-V delivers a direct reading of volumetric flow rate generally the most cost-effective solution for liquid flow monitoring -in applications ranging from general water flows to hydrocarbon fuel flow measurement. Pro-V Model M22-EM The Model M22 Energy Monitoring option permits real-time calculation of energy consumption for a facility or process. The meter can be programmed to measure steam, hot water or chilled water. The Model M22-VTP flowmeter monitors one side of the process, either sent or returned, and uses the input from a second separate temperature sensor on the opposite leg of the process to calculate the change in energy. Selectable energy units include Btu, joules, calories, Watt-hours, Megawatt-hours and Horsepower-hours. The local or remote electronics indicate two temperatures, delta T, mass total and energy total. Pro-V Model M22-VTEP, VETEP Similar to M22-VTP but with the option for an external input (T or P) via RTD or 4-20mA or one of each. S t a b i l i t y O v e r 1 2 M o n t h s Volumetric Flow Rate......... ± negligible Temperature................ ±.9 F (±.5 C) Pressure................... ±.1% of full scale R e s p o n s e T i m e Adjustable from 1 to 100 seconds Operating Specifications Any gas, liquid or steam compatible with 316L stainless steel, C276 hastelloy or A105 carbon steel. Not recommended for multi-phase fluids. P r o c e s s a n d A m b i e n t Te m p e r a t u r e Process Standard Temperature (code ST): -330 to 500 F (-200 to 260 C) Process High Temperature (code HT): to 750 F (400 C) Ambient Operating: -40 to 140 F (-40 to 60 C) Ambient Storage: -40 to 185 F (-40 to 85 C) Pressure Transducer Ratings Full Scale Operating Pressure Max. Over-Range Pressure psia bara psia bara 30 2 60 4 100 7 200 14 300 20 300 40 500 35 1000 70 1500 100 2750 175 2 VorTek Instruments, LLC 8475 West I-25 Frontage Rd., Suite 300 Longmont, CO 80504 USA Tel: 303/682-9999 Fax: 303/682-4368 info@vortekinst.com www.vortekinst.com
Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, Multivariable meter delivers mass flow, temperature, pressure, and density readings from a single installed device and reduces initial cost, installation cost and cost-of ownership over the lifetime of the instrument Mass flow equations - real gas, ideal gas, AGA 8, API 2540 Compensated mass flow reading of liquids, Energy Monitoring ability to compute and output energy use Easy to install and commission Hot tappable, process shut down not required for installation Reliable no moving parts, no fluid to sensor contact High accuracy with rangeability up to 100:1 Temperature up to 750 F Pressure up to 1500 psig Insertion style mounting permits installation in any pipe 2" and greater Field configurable ranges, outputs and displays Remote electronics option available for use in harsh environments or locations with limited access VorTek Instruments Pro-V multivariable flowmeters utilize three primary sensing elements a vortex shedding velocity sensor, an RTD temperature sensor, and a solid-state pressure transducer to measure the mass flow rate of gases, liquids and steam. Because the Pro-V is able to measure all process variables within a single device it provides exceptional accuracy, simplifies system design and reduces installation costs. To enhance reliability, the Pro-V Model M23 insertion flowmeters feature a no-moving parts design and rugged, welded construction. They are easily installed with flanged or Male NPT process connections in any pipe size of two-inches and greater. Optional retractor or hot-tap hardware simplifies maintenance operations. The Pro-V provides excellent rangeability and a low permanent pressure drop. To simplify installation and commissioning, all measured variables and programming menus are available on the instrument s easy to use display and control pad. The product line is available with a wide range of options and meter configurations to meet your specific application requirements. 4-20mA loop powered Mass Meter design saves on energy costs HART protocol communications - Standard Modbus, BACnet communications available FM, FMC, ATEX, IECEx Approved VorTek Instruments, LLC 8475 West I-25 Frontage Rd., Suite 300 Longmont, CO 80504 USA Tel: 303/682-9999 Fax: 303/682-4368 info@vortekinst.com
Pro-V Principle of Operation Vortex flowmeters measure flows of liquid, gas and steam by detecting the frequency at which vortices are alternately shed from a bluff body. According to proven laws of physics, the frequency at which the vortices are alternately shed is directly proportional to the flow velocity. Insertion vortex flowmeters measure flow by detecting the local velocity at a strategically located position within the pipe. The Pro-V M23 detects the frequency at which vortices are alternately shed from the bluff body located within the sensor head. The Pro-V M23 uses the local velocity, along with other parameters, such as fluid type, pipe size and Reynolds number to calculate the average pipe velocity, and consequently, the volumetric flow rate. Performance Specifications A c c u r a c y Mass flow rate accuracy for gas and steam based on 50-100% of pressure range. Pro-V Model M23 Multivariable Flowmeter Process Variables Liquids Gas & Steam Volumetric ± 1.2% of Rate ± 1.5% of Rate Flow Rate Mass Flow Rate ± 1.5% of Rate ± 2.0% of Rate Temperature ± 2 F (± 1 C) ± 2 F (± 1 C) Pressure ±.3% of Full Scale ±.3% of Full Scale Density ±.3% of Reading ±.5% of Reading R e p e a t a b i l i t y Volumetric Flow Rate......... ±.1% of rate Temperature................ ±.2 F (±.1 C) Pressure................... ±.05% of full scale S t a b i l i t y O v e r 1 2 M o n t h s Volumetric Flow Rate......... ± negligible Temperature................ ±.9 F (±.5 C) Pressure................... ±.1% of full scale Pro-V Model M23-VTP The Model M23-VTP offers you flow computer functionality in a compact field device. This multivariable instrument incorporates temperature and pressure sensors to provide an instantaneous reading of the compensated mass flow rate of gases, liquids and steam. In addition to outputs for totalized mass and alarm settings, the field-configurable electronics deliver up to three analog 4-20 ma outputs of five process measurements, including volumetric flow rate, mass flow rate, pressure, temperature and density. Pro-V Model M23-VT The Model M23-VT integrates a precision 1000 Ohm platinum RTD temperature sensor that can be used to calculate and output a compensated mass reading. This device is typically used to measure flow rates of saturated steam. Pro-V Model M23-V The Model M23-V delivers a direct reading of volumetric flow rate -generally the most cost-effective solution for liquid flow monitoring in applications ranging from general water flows to hydrocarbon fuel flow measurement. Pro-V Model M23-EM The Model M23 Energy Monitoring option permits real-time calculation of energy consumption for a facility or process. The meter can be programmed to measure steam, hot water or chilled water. The Model M23-VTP flowmeter monitors one side of the process, either sent or returned, and uses the input from a second separate temperature sensor on the opposite leg of the process to calculate the change in energy. Selectable energy units include Btu, joules, calories, Watt-hours, Megawatt-hours and Horsepower-hours. The local or remote electronics indicate two temperatures, delta T, mass total and energy total. Pro-V Model M23-VTEP, VETEP Similar to M23-VTP but with the option for an external input (T or P) via RTD or 4-20mA or one of each. R e s p o n s e T i m e Adjustable from 1 to 100 seconds Operating Specifications Any gas, liquid or steam compatible with 316L stainless steel. Not recommended for multi-phase fluids. P r o c e s s a n d A m b i e n t Te m p e r a t u r e Process Standard Temperature (code ST): -330 to 500 F (-200 to 260 C) Process High Temperature (code HT): to 750 F (400 C) Ambient Operating: -40 to 140 F (-40 to 60 C) Ambient Storage: -40 to 185 F (-40 to 85 C) Pressure Transducer Ratings Full Scale Operating Pressure Max. Over-Range Pressure psia bara psia bara 30 2 60 4 100 7 200 14 300 20 600 40 500 35 1000 70 1500 100 2500 175 2 VorTek Instruments, LLC 8475 West I-25 Frontage Rd., Suite 300 Longmont, CO 80504 USA Tel: 303/682-9999 Fax: 303/682-4368 info@vortekinst.com www.vortekinst.com
Turbo Pro Multivariable Flowmeter Model Pro-T Insertion Turbine Mass Flow Meter Pro-T TM Advantage: Volumetric or mass flow monitoring of most liquids, Multivariable meter delivers mass flow, temperature, pressure, and density readings from a single installed device and reduces initial cost, installation cost and cost-of ownership over the lifetime of the instrument Compensated mass flow reading of liquids, Easy to install and commission Hot tappable, process shut down not required for installation High accuracy with rangeability up to 17:1 Temperature -450 to 850 F Pressure up to 1500 psig Insertion style mounting permits installation in any pipe 2" and greater Field configurable ranges, outputs and displays Remote electronics option available for use in harsh environments or locations with limited access 4-20mA loop powered Mass Meter design saves on energy costs HART protocol communications - Standard Modbus, BACnet communications available VorTek Instruments Model Pro-T multivariable flowmeters utilize three primary sensing elements a turbine sensor, an RTD temperature sensor, and a solid-state pressure transducer to measure the mass flow rate of gases, liquids and steam. Because the TurboPro is able to measure all process variables within a single device it provides exceptional accuracy, simplifies system design and reduces installation costs. They are easily installed with flanged or Male NPT process connections in any pipe size of two-inches and greater. Optional retractor or hot-tap hardware simplifies maintenance operations. TurboPro Model Pro-T provides excellent rangeability and can measure very low flow rates with negligible permanent pressure drop. Additionally rotors are interchangeable, making this meter a good choice for installations with step changes in seasonal flow rates. To simplify installation and commissioning, all measured variables and programming menus are available on the instrument s easy to use display and control pad. The product line is available with a wide range of options and meter configurations to meet your specific application requirements. FM, FMC, ATEX, IECEx Approved VorTek Instruments, LLC 8475 West I-25 Frontage Rd., Suite 300 Longmont, CO 80504 USA Tel: 303/682-9999 Fax: 303/682-4368 info@vortekinst.com
TurboPro Principle of Operation Insertion turbine flow meters measure flows of liquid, gas, and steam by detecting the frequency of rotation of the turbine blades. According to the proven laws of physics, the frequency at which the turbine rotates is directly proportional to the flow velocity. Insertion turbine flow meters measure flow by detecting the local velocity at a strategically located position within the pipe. The TurboPro TM detects the frequency within the sensor head. It uses the local velocity, along with other parameters such as fluid type, pipe size, and Reynolds Number to calculate the average pipe velocity, and consequently, the volumetric flow rate. Performance Specifications A c c u r a c y Mass flow rate accuracy for gas and steam based on 50-100% of pressure range. Turbo Pro Model Pro-T Multivariable Flowmeter Process Variables Liquids Gas & Steam Volumetric Flow Rate ± 1.2% of Rate ± 1.5% of Rate Mass Flow Rate ± 1.5% of Rate ± 2.0% of Rate Temperature ± 2 F (± 1 C) ± 2 F (± 1 C) Pressure ±.3% of Full Scale ±.3% of Full Scale Density ±.3% of Reading ±.5% of Reading R e p e a t a b i l i t y Volumetric Flow Rate......... ±.1% of rate Temperature................ ±.2 F (±.1 C) Pressure................... ±.05% of full scale TurboPro Model Pro-T -VTP The Model Pro-T offers you flow computer functionality in a compact field device. This multivariable instrument incorporates temperature and pressure sensors to provide an instantaneous reading of the compensated mass flow rate of gases, liquids and steam. In addition to outputs for totalized mass and alarm settings, the field-configurable electronics deliver up to three analog 4-20 ma outputs of five process measurements, including volumetric flow rate, mass flow rate, pressure, temperature and density. TurboPro Model Pro-T -VT The Model Pro-T -VT integrates a precision 1000 Ohm platinum RTD temperature sensor that can be used to calculate and output a compensated mass reading. This device is typically used to measure flow rates of saturated steam. TurboPro Model Pro-T -V The Model Pro-T -V delivers a direct reading of volumetric flow rate generally the most cost-effective solution for liquid flow monitoring in applications ranging from general water flows to hydrocarbon fuel flow measurement. TurboPro Model Pro-T -EM The Model Pro-T -EM Energy Monitoring option permits real-time calculation of energy consumption for a facility or process. The meter can be programmed to measure steam, hot water or chilled water. The Model Pro-T -EM flowmeter monitors one side of the process, either sent or returned, and uses the input from a second separate temperature sensor on the opposite leg of the process to calculate the change in energy. Selectable energy units include Btu, joules, calories, Watt-hours, Megawatt-hours and Horsepower-hours. The local or remote electronics indicate two temperatures, delta T, mass total and energy total. TurboPro Model Pro-T -VTEP, VETEP Similar to Pro-T-VTP but with the option for an external input (T or P) via RTD or 4-20mA or one of each S t a b i l i t y O v e r 1 2 M o n t h s Volumetric Flow Rate......... ± negligible Temperature................ ±.9 F (±.5 C) Pressure................... ±.1% of full scale R e s p o n s e T i m e Adjustable from 1 to 100 seconds Operating Specifications Any gas, liquid or steam compatible with 316L stainless steel and other listed wetted materials. Not recommended for multi-phase fluids. P r o c e s s a n d A m b i e n t Te m p e r a t u r e Process Standard Temperature (code ST): -67 to 450 F (-55 to 238 C) Process High Temperature (code HT): -488 to 850 F (-267 to 454 C) Ambient Operating: -40 to 140 F (-40 to 60 C) Ambient Storage: -40 to 185 F (-40 to 85 C) Pressure Transducer Ratings Full Scale Operating Pressure Max. Over-Range Pressure psia bara psia bara 30 2 60 4 100 7 200 14 300 20 600 40 500 35 1000 70 1500 100 2500 175 2 VorTek Instruments, LLC 8475 West I-25 Frontage Rd., Suite 300 Longmont, CO 80504 USA Tel: 303/682-9999 Fax: 303/682-4368 info@vortekinst.com www.vortekinst.com
M23 Pro-T M O U N T I N G A C C E S S O R I E S VorTek Instruments, LLC 8475 West I-25 Frontage Rd. Suite 300 Longmont, CO 80504 USA Tel: 303/682-9999 Fax: 303/682-4368 info@vortekinst.com
Gate Valves Threaded Kits 2" 3000# full coupling 2" X 3 " sch 80 nipple 2" FxF NPT gate Valve H 2" 3000# threaded weld coupling Gate Valves Threated Kits Model Code Max Pressure Max Temperatre Material Class Connection Face to face Centerline to H(if Kit Supplied) top (open) VKBT-125() 200 PSI AT 100F 400 F AT 125 PSI BRONZE 125 THREATED 3.35 [85.1] 11.65 [295.9] 11.26 [286.0] VKBT-150() 300 PSI AT 100F 400 F AT 150 PSI BRONZE 150 THREATED 3.88 [98.6] 12.19 [309.6] 11.79 [299.5] VKBT-200() 400 PSI AT 100F 550 F AT 200 PSI BRONZE 200 THREATED 3.96 [100.6] 12.19 [309.6] 11.87 [301.5] VKBT-300() 1000 PSI AT 100F 550 F AT 300 PSI BRONZE 300 THREATED 3.96 [100.6] 12.19 [309.6] 11.87 [301.5] VKCT-800() 1975 PSI AT 100F 750 F AT 1345 PSI CARBON STEEL 800 THREATED 5.62 [142.7] 13.00 [330.2] 13.53 [343.7] VKCT-200() 275 PSI AT 100F 350 F AT 200 PSI STAINLESS STEEL 200 THREATED 3.74 [95.0] 7.44 [189.0] 11.65 [295.9] VKST-800() 1920 PSI AT 100F 1123 F AT 800 PSI STAINLESS STEEL 800 THREATED 5.25 [133.4] 11.25 [285.8] 13.16 [334.3] (Specify pipe OD in inches in parenthesis) Flanged Gate Valves Centerline to top (open) Face to Face Flanged Gate Valves Model Code Max Pressure Max Temperature Material Class Connection Face to face Centerline to top (open) VACF-150 285 PSI AT 100F 750F AT 95 PSI CARBON STEEL 150 FLANGED 7.00 [177.80] 17.00 [431.80] VACF-300 740 PSI AT 100F 750F AT 505 PSI CARBON STEEL 300 FLANGED 8.50 [215.90] 18.00 [457.20] VACF-600 1480 PSI AT 100F 750F AT 1010 PSI CARBON STEEL 600 FLANGED 11.50 [292.10] 18.00[457.20] VASF-150 275 PSI AT 100F 750F AT 95 PSI STAINLESS STEEL 150 FLANGED 7.00 [177.80] 17.00 [431.80] VASF-300 720 PSI AT 100F 750F AT 425 PSI STAINLESS STEEL 300 FLANGED 8.50 [215.90] 18.00 [457.20] VASF-600 1440 PSI AT 100F 750F AT 855 PSI STAINLESS STEEL 600 FLANGED 11.50 [292.10] 18.00 [457.20]
Flanged Adapters Raised Face Weld Neck Flange 2" Schedule 40 H 1/16 Field Weld Butt-Weld Outlet Fitting 2" 3000# Existing Pipe Flanged Adapters Model Code Material Class Connection H PACF - 150() CARBON STEEL 150 FLANGED 4.00 [101.6] PACF - 300() CARBON STEEL 300 FLANGED 4.25 [107.9] PACF - 600() CARBON STEEL 600 FLANGED 4.62 [117.3] PASF - 150() STAINLESS STEEL 150 FLANGED 4.00 [101.6] PASF - 300() STAINLESS STEEL 300 FLANGED 4.25 [107.9] PASF - 600() STAINLESS STEEL 600 FLANGED 4.62 [117.3] (Specify pipe OD in inches in parenthesis) Pipe Adapters 2" FNPT 1.5" (38.1 mm) Threaded pipe adapter 2" 3000# Existing Pipe Field Weld Pipe Adapters Model Code Material Connection PACT( ) CARBON STEEL THREADED PAST( ) STAINLESS STEEL THREADED (Specify pipe OD in inches in parenthesis)
A leader in precision multivariable flowmeters for the measurement of liquid,gas,steam and energy. VorTek Instruments, LLC 8475 West I-25 Frontage Rd., Suite 300 Longmont, CO 80504 USA Tel: 303/682-9999 Fax: 303/682-4368 info@vortekinst.com