AIR DISTRIBUTOR. PART NUMBER (Including, but not inclusive) AD28483-_ALB, AD28563-_ALB, AD36097-_ALB, AD36098-_ALB, AD28485-_ALB

Similar documents
RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Beverage Systems. Component Inspection and Service TSB-Y Date: Subject: Products Affected: Description: July Inspection of CO 2

MEGR-1912 Instruction Manual

170-CG Feed Unit SPONGE-JET USER MANUAL. Sponge-Jet, Inc. (USA) 14 Patterson Lane Newington, NH

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

Booster Pump PB4-60 Replacement Kits

RD(H)20/25 Pressure-Reducing Regulator User Manual

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

MODEL PAF 450 ASSEMBLY

Installation Instructions

Anti-flood device Model B-1

Adjustable. Unloader Valve. O&M Manual. Part #

1805 Series Relief Valves

INSTALLATION & MAINTENANCE INSTRUCTION

HYDRAULIC PUNCH DRIVER 38456, 38520, 7306 / 7306SB, 7310 / 7310SB, 7506, 7606SB, 7610SB, 7625 / 7625Pg / 7625PgSB, 7646 / 7646Pg / 7646PgSB

Freedom8 ShoeBox Compressor Manual

Your safety and the safety of others are very important.

SUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide

3/8" Dr. Air Butterfly Impact Wrench

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

Model VR6 System. Installation, Operation & Maintenance

Mounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type

DK ton, Double-acting, Die-type Crimping Tool

Float Operated Level Controllers

Hydraulic Punch Drivers

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

Installation, Operation & Maintenance Manual for Flo-Max Coupler Bracket Model FM150

Installation Instructions and valve Maintenance Rev. 0 of 29/09/15

Product Manual. Description. Specifications. CVS Type 1301F and CVS Type 1301G Regulator. Introduction

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

Halsey Taylor Owners Manual STOP!

CS150 CAP STAPLER OWNER S MANUAL

1301 Series High-Pressure Regulators

REL-510H WARNING NOTICE 12 TON SINGLE ACTING REMOTE HYDRAULIC CRIMPING HEAD

RASP RX3 Feed UnitTM SPONGE-JET USER MANUAL. Sponge-Jet, Inc. (USA) 14 Patterson Lane Newington, NH

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y

Natural Gas Conversion Kit

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

Lock Up Valves YT-400, YT-405 USER'S MANUAL

Speed control assembly model A-1

SIMPLAIR PIPING TOOL. JXT Company

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION

Installation, Operation and Maintenance Manual for Back Pressure Regulator

LRS(H)4 Pressure-Reducing Regulator User Manual

Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP

750 Cable Cutter INSTRUCTION MANUAL

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

TECHNICAL DATA. Q= Cv S

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

Installation, Operation, Maintenance Manual For Quick-Jaw Models AL363, L364 & AL366


RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

GREIG FILTERS, INC. OPERATION MANUAL

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL

4 IN. BALL LAUNCHER Engine Mounted / PTO Driven

V43 Pressure Actuated Water Regulating Valve

Installation Troubleshooting Maintenance Instructions Installation / Start-up

PDY TON HYDRAULIC CRIMPING TOOL WARNING

Operation & Maintenance Manual Place this manual with valve or person responsible for maintenance of the valve

Installation Instructions and valve Maintenance Rev. 0 of 21/09/15

Installation Instructions

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

UBP32 Sealed Balanced Pressure Thermostatic Steam Trap for use with PC_ Pipeline Connectors Installation and Maintenance Instructions

35 TON HYDRAULIC PUNCH WARNING

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

170-SJ Feed UnitTM 470-SJ Feed UnitTM

Installation and Service Manual

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

MEGR-1627 Instruction Manual

Full Internal Relief Valves Instruction Manual

MANUAL: Jumbo Siamese and Jumbo Wye

Mooney * Noise Controller Installation, Operation, and Maintenance Manual

64 Series Pressure Reducing Regulators

Operation Manual Guillotine Cutter RC-5

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

Easy Nest Kits. Installation Suggestions

INSTRUCTION MANUAL Kobelco Eagle Marine Water Lubricated Stern Tube Seals

APCO ARV CLEAN WATER AIR RELEASE VALVES. Model 50A

Pressure Dump Valve Service Kit for Series 2300 Units

Inverted Bucket Steam Trap IB 16A-7

TECHNICAL DATA. Inlet Type Outlet Type OBSOLETE. 4. TECHNICAL DATA Approvals:

TECHNICAL DATA DELUGE VALVE, MODEL F-1 STRAIGHT THROUGH STYLE

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

MANUAL: Jumbo Gate Valve

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Interface Devices, Inc. Hydraulic Mini Mule

Aluminum 13 cu tank Includes regulator Fill pressure: 3,000 psi (200 bar) Output: 1,100 psi +/- 10% (75bar)

Masoneilan* 78 Model Air Filter Regulator

Cat #: 7310SB UPC #: Spec:

Types S100K and S102K Pressure Regulators

Fit Testing. C50 APR New Equipment Training Module March 2010 Rev01

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

Transcription:

Manual #: MM-AD001 12/5/11 Rev. A Page 1 of 8 PART NUMBER (Including, but not inclusive) AD28483-_ALB, AD28563-_ALB, AD36097-_ALB, AD36098-_ALB, AD28485-_ALB

Manual #: MM-AD001 12/5/11 Rev. A Page 2 of 8 Table of Contents 1.0 General Page 3 2.0 Description & Intended Use Page 4 3.0 Installation Page 5 4.0 Inspection & Testing Page 5 5.0 Disassembly & Rebuild Page 6 6.0 Troubleshooting Guide Page 7 OPEN 3 OPEN 2 OPEN 1 PULL TO CHARGE PUSH PULL & HOLD TO CHARGE PUSH CLOSE CLOSE CLOSE TO CLOSE TO CLOSE Figure 1 No. Description Req. Material Part No. 1A Non-Sequential - Spring Neutral Module AD28483-0ALB 1B Non-Sequential - Push-Pull Module AD28563-0ALB 1 Alumimun/Nitrile 1C Sequential - Spring Neutral Module AD36097-0ALB 1D Sequential - Push-Pull Module AD36098-0ALB 2 Toggle only 1 Alumimun/Nitrile AD75592-ALB 3 End Plate 1 Aluminum 75643AL 4 Mirror End Plate 1 Aluminum 75644AL 5 Label - 1 Through 8 1 Vinyl AD75596

Manual #: MM-AD001 12/5/11 Rev. A Page 3 of 8 1.0 General 1.1 It is strongly recommended that this entire manual be read prior to any operation, disassembly, or assembly of this equipment. 1.2 Betts Industries, Inc. provides this manual as a guideline for reference only and assumes no responsibility for personal or property damage that may occur in conjunction with this manual. Betts Industries, Inc. cannot be held responsible for incorrect installation, operation or maintenance of product. 1.3 Betts Industries, Inc. recommends all equipment be placed on a regular maintenance schedule that includes the routine replacement of seals and gaskets and visual inspection for leaks and corrosion. The end user must make their own determination and set their own schedule based upon use and environment. In some cases, regulations may dictate the minimum testing frequency of items. Make sure operators are aware of all applicable codes. 1.4 Only trained personnel should attempt to perform maintenance on this equipment. 1.5 As with any maintenance work, proper safety gear and procedures must be used at all times. A list of hazards may include but are not limited to contents under pressure, loaded springs, residual product, flammable liquid and vapors, pinch points. 1.6 Safety alert symbols are used to alert operator to potential personal injury hazards. These symbols are per ANSI 2535.5 and are listed below. Operator MUST obey all instructions that follow a safety symbol. Alerts will be used to indicate known safety concerns. Additional concerns are possible and should be identified and avoided by the operator. Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices. 1.7 Product Warranty shall be void if product is subject to misapplication, misuse, neglect, alteration or damage. 1.8 Specific design details described in this document are for reference only and are subject to change without notice. See Betts Industries, Inc. web page for the most recent revision to this document. www.bettsind.com 1.9 For additional questions or more detailed technical assistance, contact the Betts Industries, Inc. Sales or Engineering Department at (814)723-1250.

2.0 Description and Intended Use Manual #: MM-AD001 12/5/11 Rev. A Page 4 of 8 2.1 The Betts air distributor is designed as a corrosion resistant, modular, lightweight and compact air distribution system that can be used to control any sequential or non-sequential air operated valve or vent system. 2.2 The distributor body is made from anodized aluminum, with internal parts made from brass and stainless steel with nitrile seals. 2.3 The individual valve toggle switches are easily accessible for replacement. 2.4 Push-to-connect fittings allow quick and easy installation with ¼ air lines. 2.5 Master Control Valve Options: 2.5.1 Spring Neutral The spring neutral master control valve allows for the air system to be manually charged and automatically isolates the system from the air supply when the master control is released. o Pull and hold the knob out until the system is charged with air pressure wink will turn green. o Release knob to neutral position air is trapped in system (no air flows to valves and no air flows back from valve system is isolated). o Push the knob in and the air is fully vented from the system. Isolation of the air supply allows for more effective emergency shut down by a fusible plug or end of line remote. 2.5.2 Push-Pull 2.6 Piping options: The push-pull master control valve is a two position detent valve. o Pull the knob out and the system is charged with air pressure wink will turn green. o Push the knob in and the air is fully vented from the system. 2.6.1 Non-Sequential The non-sequential piping option has a single air input, AIR IN. When charged, allows the air to pass directly to the toggles. See Section 3 for possible piping layout. 2.6.2 Sequential The sequential piping option has a single air input, AIR IN. When charged, air is directed out of the module through the A-OUT port to be sent to sequential vents. The air is returned to the module from the last sequential vent through the AIR RETURN port and is then sent to the toggles. See Section 3 for possible piping layout.

Manual #: MM-AD001 12/5/11 Rev. A Page 5 of 8 2.7 The individual compartment toggle valves are used to open and close the emergency valves. 2.8 The master control valve can be used as a complete system shutdown. If the master control knob is depressed to the detent exhaust position, air is fully vented from the system, shutting down all valves/vents connected to the toggle outlets. 3.0 Installation 3.1 Be sure that all tubes are cut square with no burrs before inserting into quick connect fittings. 3.2 Non-Sequential Possible Piping Layout: 3.3 Sequential Possible Piping Layout:

4.0 Inspection and Testing 4.1 Hook up air lines accordingly. Manual #: MM-AD001 12/5/11 Rev. A Page 6 of 8 4.2 Apply air pressure, 125 psi max, to the system. 4.2.1 Inspect for leaks around wink. If leaks are present, replace module. 4.2.2 Inspect quick connect fittings for leakage between fitting and aluminum housing. If leaking on module, replace module. If leaking on toggle(s), replace toggle(s). 4.2.3 Inspect quick connect fittings for leakage between fitting and air line. If leaking, remove air line, inspect end of air line, square off and deburr if necessary, retry. If leaking persists, replace leading module or toggle.

5.0 Disassembly and Rebuild Instructions Manual #: MM-AD001 12/5/11 Rev. A Page 7 of 8 5.1 To replace module (1A, 1B, 1C, 1D). 5.1.1 Remove 2 cap screws in end plate (3). It is ok if Toggle Connectors come out with cap screws 5.1.2 Remove toggles (2) and set aside. 5.1.3 Remove toggle connectors from module (1A, 1B, 1C, 1D). 5.1.4 Replace module (1A, 1B, 1C, 1D) being sure o-ring is in place and surface of module and toggles are clean and free from debris. Apply high quality removable thread locking compound to threads of cap screws and reassemble toggle connectors and cap screws. Toggle Connectors O-ring Cap Screws 5.2 To replace toggle (2). 5.2.1 Remove 2 cap screws in end plate (3). It is ok if Toggle Connectors come out with cap screws 5.2.2 Slide toggles (2) from toggle connectors. 5.2.3 Remove label (5) from toggles. 5.2.4 Replace non-functioning toggle (2) and slide all toggles back onto toggle connectors being sure o-rings are in place and surface of module and toggles are clean and free from debris. Apply high quality removable thread locking compound to threads of cap screws and reassemble toggle connectors and cap screws. SEE TROUBLE SHOOTING GUIDE ON PAGE 8

Troubleshooting Guide Manual #: MM-AD001 12/5/11 Rev. A Page 8 of 8 Problem Cause Solution Valve drifts closed System will not stay charged Toggle will not stay in closed position System will not exhaust when toggle is switched to the CLOSED position Leak in air system Module knob is damaged and will not stay at charged position Toggle finger is broken O-ring in toggle is damaged or worn out Toggle is clogged or not operating correctly. Check fittings and air lines for damage or leaking. Refer to Section 5.1 to replace module. Refer to Section 5.2 to replace toggle. Refer to Section 5.2 to replace toggle. Short term wiggle toggle slightly toward the open position. This should allow the air to exhaust. Long term Refer to Section 5.2 to replace the toggle.