T208VR Series Tank Blanketing Vacuum Regulator

Similar documents
Y692VB Series Vacuum Breaker

Type R622 Pressure Reducing Regulator

1805 Series Relief Valves

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

Type 1190 Low-Pressure Gas Blanketing Regulator

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

CP200 Series Commercial / Industrial Pressure- Loaded Pressure Reducing Regulator

Type EZH Relief or Backpressure Regulator

Type ACE95jr Tank Blanketing Valve

Types 627W and 627WH Direct-Operated Pressure Reducing Liquid Regulators

66 Series Direct-Operated Regulators and Vacuum Service Equipment

1301 Series High-Pressure Regulators

Type Y692 Gas Blanketing Regulator System

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

1805 Series Relief Valves

Types ACE95 and ACE95Sr Tank Blanketing Valves

Types ACE95 and ACE95Sr Tank Blanketing Valves

Types ACE95 and ACE95Sr Tank Blanketing Valves

1305 Series Pressure Reducing Regulators

971 Series Pressure Reducing Regulators

Type EZL Pressure Reducing Regulator for Low Differential Pressure Applications

Type EZL Pressure Reducing Regulator for Low Differential Pressure Applications

Type 99 Pressure Reducing Regulators

1301 Series High-Pressure Regulators

64 Series Pressure Reducing Regulators

Type Cronos Pressure Reducing Regulator

Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications

Type 63EG Relief Valve or Backpressure Regulator

PRESSURE REGULATORS. Type A/140. Process Management TM

PRESSURE REGULATORS. Type B/240. Process Management TM

Type 92S Pilot-Operated Steam Regulator

627 Series Pressure Reducing Regulators

Noth American 7347 High Pressure Gas Regulators

T208 Series Tank Blanketing Vapor Recovery Regulators

RB Series Regulating System

S300 Series. Valve Link. Features. Fisher Controls

Type 299 Pressure Reducing Regulators

RELIEF VALVES. V Series. Process Management TM. Type V/20-2. Type V/50. Type V/60

Type FEQ Slam-Shut Valve

CSB400 Series Commercial / Industrial Pressure Reducing Regulators

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

Types S100K and S102K Pressure Regulators

Bulletin 71.6:OSE. Type OSE Slam-Shut Valve. Features and Benefits. Introduction

299H Series Pressure Reducing Regulators

630 Series Regulators and Relief Valves

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

CSB400 Series Commercial / Industrial Pressure Reducing Regulators

PRO-50 Instrument Supply Regulator

627 Series Pressure Reducing Regulators

Type HSR Pressure Reducing Regulator for Residential, Commercial, or Industrial Applications

RELIEF VALVES. Type VS- FL. Process Management TM

SLAM-SHUT VALVES. Type BM5. Process Management TM

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

V DFX Series. Direct-Operated Tank Blanketing Regulator Manual D103808X012

MEGR-1627 Instruction Manual

Type 1098-EGR. Pilot-Operated Valve Link Regulators. Features. Fisher Controls

Types 1098-EGR and 1098H-EGR Pressure Reducing Regulators

Types S108K and S109K Pressure Reducing Regulators with Integral Slam-Shut Device

Type CT88 Backpressure Regulator

299H Series Pressure Reducing Regulators

Model 1800 PFM Series Regulator. Technical Bulletin

299H Series. 1% Accuracy for Fixed Factor Billing (PFM) I nlet Pressure up to 175 psig / 12.1 bar. Rugged Construction. Compact.

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

RESIDENTIAL REGULATORS

Types 1098-EGR and 1098H-EGR Pressure Reducing Regulators

North American 7339 High Pressure Gas Regulators

CS200 Series Commercial / Industrial Pressure Reducing Regulators

Type OSE. Type OSE Slam-Shut Valve. Features and Benefits. Introduction. Bulletin 71.6 D102356X012. April 2018

Types 95L and 95H Pressure Regulators

North American 7337A/B/C-4 High Pressure Gas Regulators

EZH and EZHSO Series Pressure Reducing Regulators

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

MEGR-1912 Instruction Manual

VS100 Series Slam-Shut Device

SLAM-SHUT VALVE. Type OSE CONTENTS INTRODUCTION CHARACTERISTICS. Scope of Manual. Material. Product Description. Connections

VSX4 Series Slam-Shut Device

1800CPB2 Service Regulators Maximum Inlet Pressure 125 PSIG

SLAM-SHUT VALVES. Type BM6X. Process Management TM

EZR Series Pressure Reducing Regulator

Types 749B and R130 Changeover Manifolds

Tank Blanketing Pressure Regulators RHPS Series

General. Rugged, Reliable with Value-added Features. Pipe Sizes. Temperature Limits. Spring Ranges. Buried Service. Increased Outlet Pipe Sizes

V DGX Series. Direct-Operated Regulators Manual D103834X012

1800CPB2 Pilot-Loaded Service Regulators

Type 4660 High-Low Pressure Pilot

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

1800CPB2 Service Regulators

61R2 STANDARD REGULATOR COMPACT REGULATOR. Phone Fax

Series 100 Slam Shut Valve. Technical Bulletin

SR100 Series Service Regulators. Technical Bulletin

Mark 630 Series. High Pressure Regulators Mark 630 High Pressure Regulators. High Pressure Regulators. Features

RELIEF VALVES. V Series. Process Management TM. Type V/20-2. Type V/50. Type V/60

VAREC 180 SERIES PRESSURE REGULATORS

OBSOLETE DOCUMENT. VSX4 Series Slam-Shut Device. VSX4 Series. Contents. Introduction. Scope of the Manual. Product Description. !

1800C and 1800C-HC Service Regulators

299H Series Pressure Reducing Regulators

RR 16 Commercial & Industrial Regulator

Petro-Chemical & Analyzer Sampling Systems

RR 16 Commercial & Industrial Regulator

Transcription:

February 2014 T208VR Series Tank Blanketing Vacuum Regulator Figure 1. Typical T208VR Series Vacuum Regulator Introduction The T208VR Series direct-operated vacuum regulators are used where a decrease in vacuum must be limited, such as between a tank and vacuum source to control vacuum in tank. The Type T208VR has internal pressure registration. The Type T208VRM has a control line connection and blocked throat for external pressure registration. Features Tamper Resistant Adjustment Closing cap and spring case on many types allow installation of sealing wire to discourage or detect unauthorized adjustment of pressure setting. Precision Control of Low Pressure Settings Large diaphragm area provides more accurate control at low pressure settings. Easy Conversion The T208VR Series Vacuum Regulators are easily adapted between external and internal registration. Common Spare Parts The Types T208VR and T208VRM share common spare parts with other T208 Series products. Corrosion Resistance Constructions are available in a variety of materials for compatibility with corrosive process gases. D103758X012 www.fisherregulators.com

Specifications This section lists the specifications of the T208VR Series Tank Blanketing Vacuum Regulator. Factory specification, such as maximum temperature, maximum inlet and outlet pressures, spring range and seat or orifice size are stamped on the nameplate fastened on the regulator at the factory. Available Configurations Type T208VR: Direct-operated vacuum regulator with internal pressure registration Type T208VRM: Direct-operated vacuum regulator with blocked throat and control line connection for external pressure registration Body Sizes and End Connection Styles BODY SIZE END CONNECTION STYLE Inch DN Gray cast iron Stainless steel 3/4 or 1 20 or 25 NPT NPT or CL150 RF Maximum (Casing) Pressure (1) 35 psig / 2.4 bar Maximum Emergency Vacuum Pressure (1) Full Vacuum Maximum Operating Vacuum Pressure (1) See Table 2 Change in Control Pressure to Wide-Open (1) See Table 2 Pressure Registration Type T208VR: Internal Type T208VRM: External Orifice Size 7/16 inch / 11 mm Capacities See Table 2 Flow Coefficients Regulating: C g : 95 C v : 3.01 C 1 : 31.4 Wide Open: C g : 127 C v : 3.66 C 1 : 34.8 Material Temperature Capabilities (1) Nitrile (NBR): -20 to 180 F / -29 to 82 C Fluorocarbon (FKM): 40 to 300 F / 4 to 149 C Spring Case Connection 1/4 NPT Diaphragm Case Connection 1/2 NPT Construction Materials See Table 1 Pressure Setting Adjustment Adjusting nut Additional Options Umbrella vent assembly for spring case connection Approximate Weight 19 pounds / 8.6 kg 1. The pressure/temperature limits in this Bulletin and any applicable standard or code limitation should not be exceeded. Principle of Operation The T208VR Series vacuum regulators are used to maintain a constant vacuum at the regulator inlet. A decrease in this vacuum (increase in absolute pressure) beyond this value registers on the diaphragm and opens the disk. This permits a downstream vacuum of lower absolute pressure than the upstream vacuum to restore the upstream vacuum to its original pressure setting. On the Type T208VR, pressure registers underneath the diaphragm. The Type T208VRM has a control line connecting the diaphragm casing to the vacuum line and an O-ring stem seal blocking the throat causing registration pressure to flow through the control line. 2

ADJUSTING SCREW CONTROL SPRING VACUUM BEING CONTROLLED VENT STEM VALVE PLUG DISK ORIFICE DIAPHRAGM PIPE PLUG PUSHER POST LEVER VACUUM PUMP HIGHER VACUUM SOURCE INLET PRESSURE (CONTROLLED VACUUM) OUTLET PRESSURE (HIGHER VACUUM SOURCE) ATMOSPHERIC PRESSURE TYPE T208VR WITH INTERNAL PRESSURE REGISTRATION ADJUSTING SCREW CONTROL SPRING VENT DIAPHRAGM CONTROL LINE CONNECTION PORT STEM SEAL THROAT SEAL STEM VALVE PLUG DISK ORIFICE PUSHER POST LEVER INLET PRESSURE (CONTROLLED VACUUM) OUTLET PRESSURE (HIGHER VACUUM SOURCE) ATMOSPHERIC PRESSURE TYPE T208VRM WITH EXTERNAL PRESSURE REGISTRATION Figure 2. T208VR Series Operational Schematic 3

Table 1. Construction Materials BODY SPRING CASE DIAPHRAGM CASE Gray cast iron or 316L/316 Stainless steel Gray cast iron or 316 Stainless steel Pusher post, orifice and stem Gray cast iron or 316L/316 Stainless steel 316 Stainless steel 302 Stainless steel LEVEL ASSEMBLY DIAPHRAGM DISK O-RING Nitrile (NBR) or Fluorocarbon (FKM) Nitrile (NBR) or Fluorocarbon (FKM) Nitrile (NBR) or Fluorocarbon (FKM) Table 2. T208VR Series Capacities SPRING RANGE, PART NUMBER AND COLOR CODE 0 to 4 inches w.c. / 0 to 10 mbar 0N039427222 Unpainted 0.05 to 0.75 psig / 3.5 to 52 mbar 0N086027022 Unpainted 0.15 to 1.75 psig / 10 to 121 mbar 0N086127022 Unpainted 0.25 to 2.75 psig / 17 to 190 mbar 0N022027022 Dark Green 1.5 to 4.75 psig / 0.10 to 0.33 bar 0N004327022 Yellow 3.0 to 12.8 psig / 0.20 to 0.88 bar 1D141827012 Blue SPRING WIRE DIAMETER SPRING FREE LENGTH MAXIMUM OPERATING INLET VACUUM CONTROL PRESSURE SETTING VACUUM MAXIMUM OPERATING OUTLET VACUUM Change in Control pressure to wide-open CAPACITY IN SCFH / Nm³/h OF 1.0 SPECIFIC GRAVITY AIR Inch mm Inch mm psig bar psig bar psig bar psig bar SCFH Nm 3 /h 0.062 1.57 3.063 77.80 5.1 0.35 2 inches w.c. 5 mbar 7.5 0.52 1 inch w.c. 2 mbar 1345 36.0 0.105 2.67 2.500 63.50 5.7 0.39 0.5 0.03 7.5 0.52 5.5 inches w.c. 14 mbar 1317 35.3 0.125 3.18 2.500 63.50 6.5 0.45 1 0.07 7.5 0.52 0.44 0.03 1289 34.5 0.135 3.43 2.500 63.50 7.4 0.51 2 0.14 7.5 0.52 0.63 0.04 1202 32.2 0.162 4.11 2.500 63.50 7.5 0.52 4 0.28 9.2 0.63 1.44 0.10 1067 28.6 0.207 5.26 2.500 63.50 12.0 0.83 9 0.62 12 0.83 3.88 0.27 898 24.1 Installation A T208VR Series regulator may be installed in any orientation as long as flow through it matches the direction of the arrow on the body. Normal installation is with the spring case vertical above or below the diaphragm case. When exposed to the weather, the vent should be protected by the optional umbrella vent or pointed down to allow condensate to drain. External dimensions and connections are shown in Figure 4. Note Downstream piping will vary with the installation, but to obtain the calculated characteristics, the pipe should be the same size as the outlet and should be straight for the first 18 inches / 457 mm. Capacity Information To determine the flow capacities for the T208VR Series vacuum regulators, use the following formula: where, Q = P 1abs C g SIN 3415 C 1 P P 1abs DEG Q = flow capacity in scfh (60 F and 14.7 psia) of air at 60 F P 1abs = absolute inlet pressure in psia (P 1 gauge + 14.7) = flow coefficient (from Specifications section) C g C 1 P = See Specification section = pressure drop across vacuum breaker or regulator 4

POSITION 1 (STANDARD) POSITION 2 POSITION 3 POSITION 4 BODY POSITION A (STANDARD) D B C VENT POSITION Figure 3. Body and Vent Position Note If the actual change in (control) pressure (from the service conditions) is less than the minimum change in (control) pressure required to fully open the vacuum regulator (Table 2), the Cg in the formula must be reduced accordingly. To obtain the correct reduced Cg, multiply the Cg from specifications table by the ratio of the actual change in (control) pressure to the minimum change in (control) pressure required to fully open the vacuum regulator. Conversion Factors To determine equivalent capacities of natural gas, propane, butane, or nitrogen, multiply the calculated capacity by the following appropriate conversion factor: 1.29 for natural gas, 0.810 for propane, 0.707 for butane or 1.018 for nitrogen. For gases of other specific gravities, divide by the square root of the appropriate specific gravity. Then, if capacity is desired in normal cubic meters per hour at 0 C and 1.01325 bar, multiply SCFH by 0.0268. 5

Ø 8.38 / 212.9 1/4 NPT VENT NPT 6.14 / 155.9 4.12 / 104.6 1/2 NPT CONTROL LINE CONNECTION 2.25 / 57.2 10.37 / 263.4 1.84 / 46.7 FLANGED 14 / 355.6 7.19 / 182.6 INCH / mm ERSA02741 Figure 4. T208VR Series Dimensions 6

Ordering Information When ordering, complete the ordering guide on this page. Refer to the Specifications section on page 2. Review the description to the right of each Ordering Guide Type (Select One) T208VR, Internal pressure registration*** T208VRM, External pressure registration*** Body Size (Select One) 3/4 inch / DN 20*** 1 inch / DN 25*** Body Material and End Connection Style (Select One) Gray Cast Iron NPT*** Stainless Steel NPT (standard)*** CL150 RF*** Vacuum (Control) Pressure Range (See Table 2, Select One) 0 to 4.0 inches w.c. / 0 to 10 mbar, Unpainted*** 0.05 to 0.75 psig / 3.5 to 52 mbar, Unpainted*** 0.15 to 1.75 psig / 10 to 121 mbar, Unpainted*** 0.25 to 2.75 psig / 17 to 190 mbar, Dark Green*** 1.5 to 4.75 psig / 0.10 to 0.33 bar, Yellow*** 3.0 to 12.8 psig / 0.20 to 0.88 bar, Blue*** Diaphragm, Disk and O-ring Material (Select One) Nitrile (NBR) (standard)*** Fluorocarbon (FKM)*** Regulators Quick Order Guide * * * Readily Available for Shipment * * Allow Additional Time for Shipment * Special Order, Constructed from Non-Stocked Parts. Consult your local Sales Office for Availability. Availability of the product being ordered is determined by the component with the longest shipping time for the requested construction. specification and the information in each referenced table or figure. Specify your choice whenever a selection is offered. Closing Cap Material (Select One) Zinc (standard)*** Steel*** Body Position (See Figure 3, Select One) Position 1 (standard)*** Position 2*** Position 3*** Position 4*** Vent Position (See Figure 3, Select One) Position A (standard)*** Position B*** Position C*** Position D*** Spring Case Orientation/Vent Type (Select One) Spring Case Up (standard) (Type Y602-11)*** Spring Case Down (Type Y602-2)*** Replacement Parts Kit (Optional) Yes, send one replacement parts kit to match this order. Specification Worksheet Application (Please designate units): Specific Use Line Size Fluid Type and Specific Gravity Fluid Temperature Does the Application Require Overpressure Protection? Yes No If yes, which is preferred: Relief Valve Monitor Regulator Shutoff Device Is overpressure protection equipment selection assistance desired? Pressure: Maximum Inlet Pressure Minimum Inlet Pressure Differential Pressure Set Pressure Maximum Flow (Q max ) Performance Required: Accuracy Requirements? Less than or Equal to: 5% 10% 20% Wide Open Other Requirements: 7

Industrial Regulators Emerson Process Management Regulator Technologies, Inc. USA - headquarters McKinney, Texas 75070 USA Tel: +1 800 558 5853 Outside U.S. +1 972 548 3574 Asia-Pacifi c Shanghai 201206, China Tel: +86 21 2892 9000 Europe Bologna 40013, Italy Tel: +39 051 419 0611 Middle East and Africa Dubai, United Arab Emirates Tel: +011 971 4811 8100 Natural Gas Technologies Emerson Process Management Regulator Technologies, Inc. USA - headquarters McKinney, Texas 75070 USA Tel: +1 800 558 5853 Outside U.S. +1 972 548 3574 Asia-Pacifi c Singapore 128461, Singapore Tel: +65 6770 8337 Europe Bologna 40013, Italy Tel: +39 051 419 0611 Chartres 28008, France Tel: +33 2 37 33 47 00 Middle East and Africa Dubai, United Arab Emirates Tel: +011 971 4811 8100 TESCOM Emerson Process Management Tescom Corporation USA - headquarters Elk River, Minnesota 55330-2445, USA Tels: +1 763 241 3238 +1 800 447 1250 Europe Selmsdorf 23923, Germany Tel: +49 38823 31 287 Asia-Pacifi c Shanghai 201206, China Tel: +86 21 2892 9499 The distinctive diamond shape cast into every spring case uniquely identifies the regulator as part of the Fisher brand and assures you of the highest-quality engineering, durability, performance, and support. For further information visit www.fisherregulators.com The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their prospective owners. Fisher is a mark owned by Fisher Controls International LLC, a business of Emerson Process Management. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. We reserve the right to modify or improve the designs or specifi cations of such products at any time without notice. Emerson Process Management Regulator Technologies, Inc. does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any Emerson Process Management Regulator Technologies, Inc. product remains solely with the purchaser. Emerson Process Management Regulator Technologies, Inc., 2013, 2014; All Rights Reserved