MULTI-STAGE VACUUM GENERATORS - GENERAL INFORMATION

Similar documents
MULTI-STAGE VACUUM GENERATORS PVP M

MULTI-STAGE VACUUM GENERATORS PVP 12 MX and 25 MX

3D drawings available at

ADJUSTABLE VACUUM GENERATORS CONEYOR

GRAPHIC DIVISION. 3D drawings available at

[Graphic Division] 10

[The Octopus vacuum lifting system] 9

WARNING. Work drop prevention check valves FPV series. Vacuum accessories. Safety handling of workpiece with several pads

T208VR Series Tank Blanketing Vacuum Regulator

Series IRV1000/2000/3000

compact ejector, Series ECM with Adjustable release pulse with silencer With filter vacuum switch: electronic 2 x PNP

Self-operated Pressure Regulators Type 2405 Pressure Reducing Valve

Booster Regulator/Air Tank

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type.

SECTION 9 CLASSIC SERIES PUMPS

STAINLESS STEEL LOW PRESSURE REDUCING VALVE LPRV ELITE

T 2523 EN Type 2406 Excess Pressure Valve Self-operated Pressure Regulators ANSI version

[Instruments for vacuum measurement, checking and adjustment] 3

SIHI LPH-X - Liquid Ring Compressors

STAP. Differential pressure controller DN 15-50

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times

Series ZFC. Air Suction Filter In-line Type with One-touch Fittings

Liquid ring vacuum pumps in compact design

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

pumping gases JET PUMP TECHNICAL DATA

Liquid ring vacuum pumps in compact design

Instruction Manual. LKHSP Self-Priming Centrifugal Pump (Appendix) ESE02222-EN

Process Pump. PAF3000 Series/PAF5000 Series

Process Pump. Self-priming makes priming unnecessary. Air operated type. Air supply port. 5 port solenoid valves. Application Example

Spin-On Filters SSF 24,25

Compact Ejectors. Compact Ejectors SCPi / SMPi Suction rate from 75 l/min to 185 l/min

OFFER / ANGEBOT / DRAFT Media Supply Module >MSM6-380< HYDRAULICS/PNEUMATICS. > Compressor unit incl. filling station to supply the modules

MECAIR CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS PRODUCT LEAFLET

Traysealer T 100. Tray packaging in the smallest space

Precision and Instrument Regulators 1/4" port size

A18W35_MASE 130_F_EN MANUAL

A17W23_MASE_MUS_EN MANUAL

TA-Modulator. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve for modulating control

Power Valve: Precision Regulator. High precision, large capacity relief regulator

Series MX pressure regulators 3/

ATH 500 M. Pumping speed ATH 500 M. 3.1 Vacuum generation / Turbopumps / Magnetically levitated / ATH 500 M. Page 398 / Part 3.1

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

NGN Series nitrogen generator

HighVac Pumps. High Vacuum Venturi Pumps. Modular Venturi Vacuum Pumps with Solenoid-Operated Vacuum and Blow-Off

VBS-9263 Series. Application. Features. Applicable Literature

PENBERTHY SERIES LM, ELL, FL, GL, GH, U, L AND 2NC FOR PUMPING GASES

AVP-F. p setting range (bar) Code No. 003H6200

PVA PIAB Vacuum Academy

VB-7263 Series. Application. Features. Applicable Literature

SMP-BC Sanitary Mixproof Valve

VACUUM REGULATORS CONTENTS

TBV-CM. Combined control & balancing valves for small terminal units For modulating control

Pneumatic spool valve islands

Wastewater combination air valve in stainless steel AISI 316 Mod. SCS

VB-7273 Series. Application. Features. Applicable Literature

Mass Flow Meter (MFM) for Gases

Blanketing Valve ZM-R. low pressure reducing valve

Pneumatic dead-weight tester Model CPB3500

2-port and 3-port seat valves, PN16

Description Total stroke Maximum Recommended Page in mm gripping force in N workpiece weight in kg

1/2 to 2-1/2 NPT; 0 to 230 PSI Advantages / Benefits

Two-port valves, male threaded, PN25

Mass Flow Controller (MFC) for Gases

Vacuum Saving Valve Series ZP2V How to Order ZP2V A5 03 Connection thread symbol for the pad Male thread connection Symbol Thread Applicable fixed ori

Composite Grippers. Composite Grippers SCG Suction capacity from 270 l/min to 650 l/min

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM

Differential pressure controller (PN 16) AVPL return mounting, adjustable setting

air nozzles Applications Making the right choice Product overview Facts about the products silvent.com 31

Cost effective. Smooth. Reliable. LOG Internal Hole Gripper

ZUERCHER TANK REGULATORS PRINCIPLES OF TANK VENTILATION

Ratio Regulator Zero Governor. FRG/6 Series

VB-7213 Series. Application. Features. Applicable Literature. 1/2" to 2" Screwed NPT Stem Up Open, Two-Way Valves General Instructions

TECHNICAL ACCESSORIES

Pneumatic valve islands

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

VB-7211 Series. Application. Features. Applicable Literature. 1/2" to 1-1/4" Union End NPT Stem Up Open, Two-Way Valves General Instructions

SAFETY LOCKOUT VALVES

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

Compressed Air Cleaning Filter Series

DAV - P. Product Catalogue DAV - P. Air release & Vacuum Break Valves. (Plastic Air Valves) DAV - P. Edition 2012

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners

USE AND MAINTENANCE MANUAL V360

Körting Liquid Jet Vacuum Ejectors

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

Air-service devices, Series MU1

VRD Series VRD40.xxxUx Double Valves for use with SKP... electro-hydraulic actuators

2-port seat valves PN25 with externally threaded connections

Cylindrical Venturi Vacuum Pumps Cylindrical Venturi Vacuum Pumps Mid J Series Principles of Operation: JS-200-ST6A used extensively in vent-less mold

3 & 4-Way Mixing & Diverting Valves

DIAPHRAGM GAS SAMPLING PUMPS

Features. General application. Technical data

indd indd

TECHNICAL DATA NOTICE

Mass Flow Meter (MFM) for gases

Pressure booster. Air Service Units Series Page. General 5.1. Pressure boosters ø Pressure boosters ø 40 c/w air pressure regulator 5.

Series 44 Self-operated Pressure Regulators. Type 44-0 B Pressure Reducing Valve. ANSI version

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

Transcription:

MULTI-STAGE VACUUM GENERATORS - GENERAL INFORMATION Our multi-stage vacuum generators produce a maximum vacuum of 90%, equal to a final vacuum level of 100 mbar abs., with different suction capacities. They operate by use of compressed air from 1 to 6 bar (g). Working principle Each ejector is based on the Venturi principle: the supply fluid (compressed air) is led high speed by a convergent pipe into the fluid to be extracted (volume of the air to be sucked). This mixture is then led into two or three divergent pipes, where its kinetic energy is transformed into pressure energy for it to enter in the environment at a higher pressure (atmospheric pressure at the exhaust). Technical features The main asset of multi-stage vacuum generators is its ability to exploit the kinetic energy of the supply compressed air via several specially dimensioned in-line ejectors, before releasing it in the atmosphere. This system allows, given the same capacity, a reduced compressed air consumption compared to the single-stage vacuum generators. The suction capacity is indirectly proportional to the differential between the pressure of the fluid to be sucked and the external (atmospheric) pressure. The reduced size and weight make multi-stage vacuum generators compact in relation to their great suction capacity. The absence of moving parts make them particularly silent and allow them to be used continuously, without developing heat. Being supplied exclusively by compressed air, these vacuum generators are explosionproof and can be used in work environments with temperatures ranging from -20 to +80 C. They are fully made with stainless materials. Thanks to all these features, a good filtration of the supply and sucked compressed air is sufficient to make these generators are fully maintenance-free. 8.28

MULTI-STAGE VACUUM GENERATORS SERIES M These vacuum generators feature multiple state of the art ejectors assembled onto small modules. One of their distinctive features is their great suction capacity compared to their reduced size. With a compressed air supply of 4 5 bar (g), they can produce a maximum vacuum equal to 85% and a suction capacity of 3.6 18 cum/h, according to the number of modules. The silencer is built-in. They are fully made with slightly anodised alloys and can be installed in any position. The multi-stage vacuum generators in this range are suited for interconnecting vacuum cup gripping systems and, in particular, in the industrial robotics sector, which requires equipment with excellent working performance, but with weight and size reduced to the minimum. P=COMPRESSED AIR CONNECTION R=EXHAUST U=VACUUM CONNECTION Art. M 3 M 7 Quantity of sucked air cum/h 3 3.4 3.6 5.4 5.8 6.2 Max. vacuum level -KPa 62 82 85 62 82 85 Final pressure mbar abs. 380 180 150 380 180 150 Supply pressure bar (g) 3 4 5 3 4 5 Air consumption Nl/s 0.5 0.7 0.8 0.8 1.2 1.4 Working temperature C -10 / +80-10 / +80 Noise level db(a) 64 70 Weight g 109 111 A 24.5 25.5 B 9 10 C 4.5 4.5 E Ø 20 24 F 11 12 G Ø G1/4 G3/8 Spare parts Sealing kit and reed valve art. 00 KIT M 3 00 KIT M 7 Note: All the vacuum data indicated in the table are valid at the normal atmospheric pressure of 1013 mbar and are obtained with a constant supply pressure. 8 Conversion ratio: inch = mm ; pounds = g = Kg GAS-NPT thread adapters available at page 1.117 8.29

MULTI-STAGE VACUUM GENERATORS M 3 and M 7 Generator Supply press. Air consumption Air capacity (Nl/s) at different vacuum levels (-KPa) Max. vacuum level art. bar (g) Nl/s 0 10 20 30 40 50 60 70 80 -KPa M 3 5.0 0.8 1.00 0.83 0.61 0.34 0.18 0.12 0.10 0.07 0.03 85 M 7 5.0 1.4 1.72 1.28 0.89 0.50 0.37 0.27 0.16 0.11 0.05 85 Generator Supply press. Air consumption Evacuation time (ms/l = s/m 3 ) at different vacuum levels (-KPa) Max. vacuum level art. bar (g) Nl/s 10 20 30 40 50 60 70 80 85 -KPa M 3 5.0 0.8 106 244 491 969 1642 2398 4004 7128 10122 85 M 7 5.0 1.4 61 142 285 563 954 1394 2328 4144 5885 85 8.30

MULTI-STAGE VACUUM GENERATORS M 10, M 14 and M 18 8 P=COMPRESSED AIR CONNECTION R=EXHAUST U=VACUUM CONNECTION Art. M 10 M 14 M 18 Quantity of sucked air cum/h 7.7 8.5 9.4 10.2 11.6 12.6 14.8 16.5 18.0 Max. vacuum level -KPa 62 82 85 62 82 85 62 82 85 Final pressure mbar abs. 380 180 150 380 180 150 380 180 150 Supply pressure bar (g) 3 4 5 3 4 5 3 4 5 Air consumption Nl/s 1.2 1.6 1.9 1.7 2.1 2.5 2.3 2.9 3.6 Working temperature C -10 / +80-10 / +80-10 / +80 Noise level db(a) 72 72 76 Weight g 144 145 150 A 34.5 34.5 44.5 B 20 20 30 C 4.5 4.5 4.5 Spare parts Sealing kit and reed valve art. 00 KIT M 10 00 KIT M 14 00 KIT M 18 Note: All the vacuum data indicated in the table are valid at the normal atmospheric pressure of 1013 mbar and are obtained with a constant supply pressure. Conversion ratio: inch = mm ; pounds = g = Kg GAS-NPT thread adapters available at page 1.117 8.31

MULTI-STAGE VACUUM GENERATORS M 10, M 14 and M 18 Generator Supply press. Air consumption Air capacity (Nl/s) at different vacuum levels (-KPa) Max. vacuum level art. bar (g) Nl/s 0 10 20 30 40 50 60 70 80 -KPa M 10 5.0 1.9 2.61 2.00 1.55 0.80 0.64 0.50 0.29 0.19 0.09 85 M 14 5.0 2.5 3.50 2.33 1.72 1.00 0.89 0.67 0.35 0.24 0.11 85 M 18 5.0 3.6 5.00 3.50 2.78 2.02 1.02 0.75 0.44 0.30 0.14 85 Generator Supply press. Air consumption Evacuation time (ms/l = s/m 3 ) at different vacuum levels (-KPa) Max. vacuum level art. bar (g) Nl/s 10 20 30 40 50 60 70 80 85 -KPa M 10 5.0 1.9 40 93 188 371 629 918 1534 2731 3878 85 M 14 5.0 2.5 30 69 140 276 469 685 1144 2036 2892 85 M 18 5.0 3.6 21 48 98 193 327 478 799 1423 2020 85 8.32

MULTI-STAGE VACUUM GENERATORS SERIES M.. SSX These vacuum generators share the same technical features as the others of the M series described above. Their distinctive feature is their silent operation. In fact, along with thye built-in silencer, they also have an external SSX silencer for a further noise reduction. These generators are particularly recommended in work environments where the noise level must be kept within very low values. P=COMPRESSED AIR CONNECTION R=EXHAUST U=VACUUM CONNECTION Art. M 3 SSX M 7 SSX Quantity of sucked air cum/h 3.0 3.4 3.6 5.4 5.8 6.2 Max. vacuum level -KPa 62 82 85 62 82 85 Final pressure mbar abs. 380 180 150 380 180 150 Supply pressure bar (g) 3 4 5 3 4 5 Air consumption Nl/s 0.5 0.7 0.8 0.8 1.2 1.4 Working temperature C -10 / +80-10 / +80 Noise level db(a) 52 58 Weight g 109 111 A 24.5 25.5 B 9 10 C 4.5 4.5 E Ø 20 29 F 11 12 G Ø G1/4 G3/8 H 74.5 97.5 Spare parts Silencer art. SSX 1/4 SSX 3/8 Sealing kit and reed valve art. 00 KIT M 3 00 KIT M 7 Note: All the vacuum data indicated in the table are valid at the normal atmospheric pressure of 1013 mbar and are obtained with a constant supply pressure. 8 Conversion ratio: inch = mm ; pounds = g = Kg GAS-NPT thread adapters available at page 1.117 8.33

MULTI-STAGE VACUUM GENERATORS M 3 SSX and M 7 SSX Generator Supply press. Air consumption Air capacity (Nl/s) at different vacuum levels (-KPa) Max. vacuum level art. bar (g) Nl/s 0 10 20 30 40 50 60 70 80 -KPa M 3 SSX 5.0 0.8 1.00 0.83 0.61 0.34 0.18 0.12 0.10 0.07 0.03 85 M 7 SSX 5.0 1.4 1.72 1.28 0.89 0.50 0.37 0.27 0.16 0.11 0.05 85 Generator Supply press. Air consumption Evacuation time (ms/l = s/m 3 ) at different vacuum levels (-KPa) Max. vacuum level art. bar (g) Nl/s 10 20 30 40 50 60 70 80 85 -KPa M 3 SSX 5.0 0.8 106 244 491 969 1642 2398 4004 7128 10122 85 M 7 SSX 5.0 1.4 61 142 285 563 954 1394 2328 4144 5885 85 8.34 Conversion ratio: inch = mm g ; pounds = = Kg GAS-NPT thread adapters available at page 1.117

MULTI-STAGE VACUUM GENERATORS M 10 SSX, M 14 SSX and M 18 SSX P=COMPRESSED AIR CONNECTION R=EXHAUST U=VACUUM CONNECTION Art. M 10 SSX M 14 SSX M 18 SSX Quantity of sucked air cum/h 7.7 8.5 9.4 10.2 11.5 12.6 14.8 16.5 18.0 Max. vacuum level -KPa 62 82 85 62 82 85 62 82 85 Final pressure mbar abs. 380 180 150 380 180 150 380 180 150 Supply pressure bar (g) 3 4 5 3 4 5 3 4 5 Air consumption Nl/s 1.2 1.6 1.9 1.7 2.1 2.5 2.3 2.9 3.6 Working temperature C -10 / +80-10 / +80-10 / +80 Noise level db(a) 60 62 66 Weight g 144 145 150 A 34.5 34.5 44.5 B 20 20 30 C 4.5 4.5 4.5 E Ø 29 29 35 G Ø G3/8 G3/8 G1/2 H 106.5 106.5 136.5 Spare parts Silencer art. SSX 3/8 SSX 3/8 SSX 1/2 Sealing kit and reed valve art. 00 KIT M 10 00 KIT M 14 00 KIT M 18 Note: All the vacuum data indicated in the table are valid at the normal atmospheric pressure of 1013 mbar and are obtained with a constant supply pressure. 8 Conversion ratio: inch = mm ; pounds = g = Kg GAS-NPT thread adapters available at page 1.117 8.35

MULTI-STAGE VACUUM GENERATORS M 10 SSX, M 14 SSX and M 18 SSX Generator Supply press. Air consumption Air capacity (Nl/s) at different vacuum levels (-KPa) Max. vacuum level art. bar (g) Nl/s 0 10 20 30 40 50 60 70 80 -KPa M 10 SSX 5.0 1.9 2.61 2.00 1.55 0.80 0.64 0.50 0.29 0.19 0.09 85 M 14 SSX 5.0 2.5 3.50 2.33 1.72 1.00 0.89 0.67 0.35 0.24 0.11 85 M 18 SSX 5.0 3.6 5.00 3.50 2.78 2.02 1.02 0.75 0.44 0.30 0.14 85 Generator Supply press. Air consumption Evacuation time (ms/l = s/m 3 ) at different vacuum levels (-KPa) Max. vacuum level art. bar (g) Nl/s 10 20 30 40 50 60 70 80 85 -KPa M 10 SSX 5.0 1.9 40 93 188 371 629 918 1534 2731 3878 85 M 14 SSX 5.0 2.5 30 69 140 276 469 685 1144 2036 2892 85 M 18 SSX 5.0 3.6 21 48 98 193 327 478 799 1423 2020 85 8.36 Conversion ratio: inch = mm g ; pounds = = Kg GAS-NPT thread adapters available at page 1.117