Congratulations on your new VELUX INTEGRA product!

Similar documents
VELUX Modular Skylights

Product information VELUX INTEGRA Solar centre-pivot roof window GGL

VELUX Modular Skylights

Product information VELUX INTEGRA centre-pivot pine roof window GGL

Product information VELUX INTEGRA flat roof window CVP

VELUX Modular Skylights

Warranty The VELUX promise

VELUX Modular Skylights

VELUX Modular Skylights

Endrup School. Improving the preschool learning environment with daylight and fresh air

Product information VELUX Mini Dormer

1 Characteristics: 2 Installation: INSTALLATIONguide. inteo SOLIRIS IB

TUEN Old house, new life

Product information VELUX Mini Dormer / Takfönsterkupa Mini

VELUX blinds and shutters Price list (inc VAT) 1st Feb 2015 UK New Collection

Blinds and shutters. VELUX blinds and shutters. UK Price List (includes VAT) 5th February 2018 veluxblindsdirect.co.uk

VELUX PRODUCT GUARANTEE

Data Sheet VELUX INTEGRA Roller Blind

OWNER S MANUAL. All PowaKaddy electric trolleys have been awarded the Quiet Mark by the Noise Abatement Society

VELUX decoration and sunscreening 6

Dissolved Oxygen/Temp Waterproof Tester

Blinds and shutters. VELUX blinds and shutters. ROI Price List (includes VAT) 6th February 2017 veluxshop.ie

Say hello to our new generation of energy efficient roof windows

NEW Modular Skylights. Let daylight and blue sky transform your home

Heavy Duty Dissolved Oxygen Meter

Silent Gliss 5100 Autoglide Quick Start Guide

The Oxygen Sensor can be connected to all types of einstein Tablets, einstein LabMate, and einstein LabMate +.

Oxygen Sensor with Electrode

Lil Fun Walker ASSEMBLY INSTRUCTIONS ADULT ASSEMBLY REQUIRED Styles and colors may vary

HZ-300 HAZER MACHINE USER MANUAL. Congratulations on the purchase of your new ANTARI HZ-300 Haze Machine.

GPS OWNERS MANUAL. All PowaKaddy electric trolleys have been awarded the Quiet Mark by the Noise Abatement Society

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

Warranty. The VELUX promise. Specific limited product warranty 10-year No Leak installation warranty Warranty claim procedure

Operating instructions Installation instructions To be kept in the vehicle!

E Cube Lift Model: ECU Installation Instructions

o w n e r s m a n ua l Remote Launchers for Retriever Training

Read this first. Zetasizer nano series Self installation and Quick start guide MRK825-02

1 - TECHNICAL SPECIFICATIONS

Instruction Manual: VelectriX Foldaway

Operating instructions Capacitive sensors KG AC (M18) / / 2010

NEULOG OXYGEN LOGGER SENSOR GUIDE

JABBA S SAIL BARGE (THE KHETANNA) READ BEFORE UNPACKING. VEHICLE ASSEMBLY REQUIRED. NO TOOLS NEEDED. AGES 14+

Warranty. The VELUX promise. Specific limited product warranty 10-year No Leak installation warranty Warranty claim procedure

Warranty. The VELUX promise. Specific limited product warranty 10-year No Leak installation warranty Warranty claim procedure

VELUX INTEGRA FSK VAS

MAGNETIC CYCLING TRAINER SF-B0419 USER MANUAL

POWER ASSISTED BICYCLES OWNERS MANUAL

Warranty. The VELUX promise. Specific limited product warranty 10-year No Leak installation warranty Warranty claim procedure

NEW. Mallia TM modular. These products are part of Power Line Carrier technology system > See p

Chair Topper. Autoadapt. Hoisting and stowing. User manual

BR-2444 ROWING MACHINE

Camec 4 Seasons Evolution 500 x 700

WIND CLIPPER KTS ILLUM SCALE INC DEC CLIPPER WIND SYSTEM

Measuring wind speed and direction

GT-4130 STUNT PLANE. 3 Channel 2.4GHz RC Aeroplane Modelled after the famous Cessna 182 Skylane SKYLARK (GT-4130) Contents & Accessories

USER MANUAL. AirPal Air Supply. (AS-1100 North America) 1488 Limeport Pike, Coopersburg, PA airpal.com fax

Magnetic Bike. Model No: AENERGISER BODY WORX. Retain this owner s manual for future reference Read and follow all instructions in this owner s manual

Tripod Series OPERATOR S MANUAL

The Military CYPRES Quick Guide For Operators

Warranty. The VELUX promise. Specific limited product warranty 10-year No Leak installation warranty Warranty claim procedure

Operating instructions Electrical switching facility pco

push your limits Trainer overview EN

Skylight Rollers For Velux windows

This test shall be carried out on all vehicles equipped with open type traction batteries.

Reflow Oven HHL3000 INSTRUCTION MANUAL POHUA - jedyny autoryzowany przedstawiciel w Polsce

READ-ME-FIRST RMF-01. DOWNLOAD COMPLETE TECHNICAL OWNER MANUAL

User Manual. GPL 3000 e. gas detector

GV Standard X-Vent. Setup, Commissioning & Installation Guide

VELUX BLIND collection

5 Function Indicator. Outside Air Temperature (C) Outside Air Temperature (F) Pressure Altitude Density Altitude Aircraft Voltage STD TEMP SL 15000

ClubHub. User s Guide

Digital pressure gauge Model CPG500

1/6 CAL. YM62 1/5 SECOND, ALARM CHRONOGRAPH. Instructions. Features. Movement Size mm (12H-6H) x mm (3H-9H) 3.70 mm (Include battery)

VERTICAL AIR COMPRESSORS

VERTICAL AIR COMPRESSORS

TME CH LM R L A 7 T- M M L-T CHR ALM TME

Thule RideAlong Mini Front Child Bike Seat

Digital pressure gauge Model CPG500

ASSEMBLY INSTRUCTIONS FOR THE SHOOTOUT HOOPS GAME

ECE 477 Digital Systems Senior Design Project Rev 9/12. User Manual

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

CONVERTIBLE PET YARD READ ALL INSTRUCTIONS BEFORE ASSEMBLY AND USE OF PRODUCT. KEEP INSTRUCTIONS FOR FUTURE USE.

OPERATING INSTRUCTIONS

USER S MANUAL. PD1-Pedometer Watch. ENGLISH l 1

Soft Systems. Log Flume - 1. Enter Specification. Activity One ACTIVITIES. Help. for Logicator

FOLD AND ROLL PLAYBACK TABLE TENNIS TABLE

Parts of the Gun. Specifications XCR-C XCR-L. Optic Rail. Charging Handle. Sling Loop. Accessory Rails. Crane Stock. Flash Hider. Stock Pad.

FOLD AND ROLL PLAYBACK TABLE TENNIS TABLE

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

1500 Follow Spot Yoke

1. Features CONTENTS. English

Laser Tag Pro: Battle Rifle

Model PSI Compressor with 3-Gallon Air Tank 12VDC

Residential skylights

USER GUIDE TO POWER ASSISTED BIKES

444C DUAL PERFORMANCE VALUE PACK

HEALTHCARE CPR Metrix

Instruction Manual. Select Language. English French German Russian. All images in this manual are illustrations only.

ECL Comfort 110, application 131 (valid as of software version 2.00)

Bristol Fire Department Standard Operating Procedures. Multi Gas Detector

Transcription:

VELUX INTEGR KLI 0//2/ Congratulations on your new VELUX INTEGR product! Thank you for buying this VELUX INTEGR product. The wall switch has been produced and tested in accordance with the newest methods and strictest requirements and will help you to get the most out of all your VELUX INTEGR products. DIRECTIONS FOR USE FOR VELUX INTEGR KLI 0//2/. 208 VELUX GROUP VELUX, THE VELUX LOGO, VELUX INTEGR, io-homecontrol ND THE io-homecontrol LOGO RE REGISTERED TRDEMRKS USED UNDER LICENCE Y THE VELUX GROUP

VELUX INTEGR KLI 0//2/ Contents Wall switch types Wall switch functionality 4 Rain sensor 5 Setup of wall switch KLI to operate VELUX INTEGR roof windows GGL/GGU or roof windows GGL/GGU with VELUX INTEGR window operators 6 Setup of wall switch KLI to operate VELUX INTEGR flat roof window CVP 7 Setup of wall switch KLI 2 to operate VELUX INTEGR solar blinds DSL/RSL/FSL/FSC 8 Setup of wall switch KLI to operate VELUX INTEGR solar awning blind MSL 9 Setup of wall switch KLI to operate VELUX INTEGR solar roller shutter SSL or SST 0 Setup of wall switch KLI to operate VELUX INTEGR solar awning blind MSG Setup of wall switch KLI /2/ to operate electrical products connected to VELUX INTEGR power supply unit KUX 0 2 Setup of wall switch KLI /2/ to operate electrical products connected to VELUX INTEGR control unit KLC 500 Setup of wall switch KLI /2/ to operate electrical products already registered in VELUX INTEGR control pad KLR 200 4 Setup of a new wall switch KLI /2/ in addition to an existing wall switch KLI /2/ 5 Setup of wall switch for group control of products 6 Manual operation of VELUX INTEGR roof windows GGL/GGU 7 Closing of VELUX INTEGR roof windows GGL/GGU in the case of power failure or discharged battery 8 Closing of VELUX INTEGR flat roof window CVP without using the wall switch 9

Wall switch types KLI 0 Wall switch KLI 0 is universal and can operate all io-homecontrol compatible VELUX INTEGR electrically or solar powered products such as roof windows, window operators, interior and exterior sunscreening and roller shutters. Furthermore, KLI 0 can operate other VELUX INTEGR accessories such as adapter KRD 00 and frame lights KR 00. Wall switch KLI 0 has a neutral design that fits all homes. You can use wall switch KLI 0 for any of the products mentioned above. More products of the same type can be operated simultaneously with one KLI 0. To pair the KLI 0, follow the instructions for the product you wish to pair it with. KLI Wall switch KLI is delivered with VELUX INTEGR roof windows and VELUX INTEGR window operators. This icon indicates that only VELUX INTEGR roof windows and VELUX INTEGR window operators can be operated with the wall switch. Note: Interior and exterior sunscreening cannot be operated/paired with this type of wall switch. KLI 2 Wall switch KLI 2 is delivered with VELUX INTEGR interior sunscreening. This icon indicates that only VELUX INTEGR interior sunscreening can be operated with the wall switch. Note: Window operators and exterior sunscreening cannot be operated/paired with this type of wall switch. KLI Wall switch KLI is delivered with VELUX INTEGR exterior sunscreening. This icon indicates that only VELUX INTEGR exterior sunscreening can be operated with the wall switch. Note: Window operators and interior sunscreening cannot be operated/paired with this type of wall switch. VELUX

Wall switch functionality Keys for operating the product a OPEN/UP or CLOSE/DOWN Short key pressure: Product will travel to maximum top or bottom position. Long key pressure: Product will travel until the key is released. Note: If several electrical products are connected to a control unit KLC 500, only one of the products (at random) can be operated in this way. STOP key b Product stops. a b Wall switch KLI has two buttons used for setup: The GER button "Open for registration". The PIR button "Register". To push the buttons, use a pointed object. VELUX 4

Rain sensor When the rain sensor is activated, the roof window will close automatically within approx. 0 seconds. The rain sensor prevents the roof window from opening for as long as it detects rain. The window can be opened again with the wall switch when the rain sensor is dry. Overruling rain sensor function Note: The following can only be carried out with wall switch KLI. To prevent water damage inside the building, the window normally cannot be opened until the rain sensor is dry again. However, it may, in some cases, take some time for the rain sensor to dry after the rain has stopped. In these cases, the rain sensor function can be overruled at the owner s own risk, see below. The overruling of the rain sensor will enable the window to open 50% for a period of 5 min. Warning! s the rain sensor function is suspended for 5 min, there is a risk of water damage to the building. Therefore, we do not recommend overruling the rain sensor if the window is left unattended. Press OPEN/UP and STOP key simultaneously for second. The window can be closed again anytime with a press on the DOWN key. VELUX 5

Setup of wall switch KLI to operate VELUX INTEGR roof windows GGL/GGU or roof windows GGL/GGU with VELUX INTEGR window operators If a non-functional wall switch must be replaced or if the wall switch cannot find certain products, the products can be prepared for registration by resetting them manually. Note: Reset products cannot be operated until they have been registered in the wall switch again. Important: This only applies to KLI. Ensure the power is turned on. Open window manually (if the window is open, you must close it by pressing the test button on the window operator). 2 There are two ways of resetting depending on window type. The ventilation flap can look like 2 or 2. 2 2 Press the test button on the window operator for at least 0 seconds. The window operator will run briefly back and forth. Note: Registration ( and 4 ) must now be completed within the next 0 minutes. 0 sec 0 sec Press PIR button on the wall switch for second. sec 4 Close the window manually. 5 The window can now be operated with the wall switch. 4 5 VELUX 6

Setup of wall switch KLI to operate VELUX INTEGR flat roof window CVP If a non-functional wall switch must be replaced or if the wall switch cannot find certain products, the products can be prepared for registration by resetting them manually. Note: Reset products cannot be operated until they have been registered in the wall switch again. Important: This only applies to KLI. Carefully remove the cover cap on the kerb. 2 Press the test button on the window operator behind the cover cap for at least 0 seconds. The window operator will run briefly back and forth. Note: Registration ( and 4 ) must now be completed within the next 0 minutes. 2 min 0 sec Press PIR button on the wall switch for second. sec 4 Refit cover cap. 4 The window can now be operated with the wall switch. VELUX 7

Setup of wall switch KLI 2 to operate VELUX INTEGR solar blinds DSL/RSL/FSL/FSC If a non-functional wall switch must be replaced or if the wall switch cannot find certain products, the products can be prepared for registration by resetting them manually. Note: Reset products cannot be operated until they have been registered in the wall switch again. Important: This only applies to KLI 2. Depending on the blind type, the RESET button will be located as shown in illustration or. Press the RESET button on the blind for 0 seconds (motor makes a brief buzzing noise, but the product does not move). Note: Registration ( 2 and ) must now be completed within the next 0 minutes. RESET 0 sec 0 sec 2 Press PIR button on the wall switch for second. 2 sec Press the STOP key and then the DOWN key within seconds. max sec 4 The blind can now be operated with the wall switch. Note: The motor must be adjusted to the size of the window before full operation of the blind begins. This is done by running the blind all the way up and down without interruption using the wall switch. 4 VELUX 8

Setup of wall switch KLI to operate VELUX INTEGR solar awning blind MSL If a non-functional wall switch must be replaced or if the wall switch cannot find certain products, the products can be prepared for registration by resetting them manually. Note: Reset products cannot be operated until they have been registered in the wall switch again. Important: This only applies to KLI. Remove plastic cover. 2 Set switch to position I. Press button P briefly. 2 Note: Registration ( 4 and 5 ) must now be completed within the next 0 minutes. P 4 Press PIR button on the wall switch for second. 4 sec 5 Press the STOP key and then the DOWN key within seconds. 5 max sec 6 Replace plastic cover. The awning blind can now be operated with the wall switch. Note: The motor must be adjusted to the size of the window before full operation of the awning blind begins. The adjustment will take place automatically the first time the awning blind is operated. efore the awning blind runs to the preferred position, it runs all the way up and down. Do not interrupt the adjustment! 6 VELUX 9

Setup of wall switch KLI to operate VELUX INTEGR solar roller shutter SSL or SST If a non-functional wall switch must be replaced or if the wall switch cannot find certain products, the products can be prepared for registration by resetting them manually. Note: Reset products cannot be operated until they have been registered in the wall switch again. Important: This only applies to KLI. Remove plastic cover. 2 Set switch to position I. Press button P briefly. 2 Note: Registration ( 4 and 5 ) must now be completed within the next 0 minutes. P 4 Press PIR button on the wall switch for second. 4 sec 5 Press the STOP key and then the DOWN key within seconds. 5 max sec 6 Replace plastic cover. The roller shutter can now be operated with the wall switch. Note: The motor must be adjusted to the size of the window before full operation of the roller shutter begins. The adjustment will take place automatically the first time the roller shutter is operated. efore the roller shutter runs to the preferred position, it runs all the way up and down. Do not interrupt the adjustment! VELUX 0 6

Setup of wall switch KLI to operate VELUX INTEGR solar awning blind MSG If a non-functional wall switch must be replaced or if the wall switch cannot find certain products, the products can be prepared for registration by resetting them manually. Note: Reset products cannot be operated until they have been registered in the wall switch again. Important: This only applies to KLI. a pen compartment on the solar O awning blind. Press and hold button. The awning blind runs back and forth times. Note: Registration ( 4 and 5 ) must now be completed within the next 0 minutes. 2 ress PIR button on the wall P switch for second. 4 Remove dome/top unit. 2 4 b 0 sec sec 5 ress the STOP key and then the P DOWN key within seconds. 5 max sec eplace dome/top unit. R The awning blind can now be operated with the wall switch. Note: The motor must be adjusted to the size of the window before full operation of the awning blind begins. The adjustment will take place automatically the first time the awning blind is operated. efore the awning blind runs to the preferred position, it opens and closes. Do not interrupt the adjustment! 6 VELUX 6 a b

Setup of wall switch KLI /2/ to operate electrical products connected to VELUX INTEGR power supply unit KUX 0 If a non-functional wall switch must be replaced or if the wall switch cannot find certain products, the products can be prepared for registration by resetting them manually. Note: Reset products cannot be operated until they have been registered in the wall switch again. Important: The wall switch type must match the relevant product(s). The products connected can be reset by removing the cover of the power supply unit and pressing the RESET button for at least 5 seconds. The connected products will run briefly back and forth in random order to indicate that they are ready for pairing. Note: Registration ( 2 and ) must now be completed within the next 0 minutes. KUX 0 RESET 24V min 5 sec 2 Press PIR button on the wall switch for second. 2 sec Press the STOP key and then the DOWN key within seconds. The products can now be operated with the wall switch. max sec VELUX 2

Setup of wall switch KLI /2/ to operate electrical products connected to VELUX INTEGR control unit KLC 500 If a non-functional wall switch must be replaced or if the wall switch cannot find certain products, the products can be prepared for registration by resetting them manually. Note: Reset products cannot be operated until they have been registered in the wall switch again. Important: The wall switch type must match the relevant product(s). The products connected can be reset by removing the cover of the control unit and pressing the RESET button for at least 0 seconds. The connected products will run briefly back and forth in random order to indicate that they are ready for pairing. Note: Registration ( 2 and ) must now be completed within the next 0 minutes. KLC 500 0 sec 2 Press PIR button on the wall switch for second. 2 sec Press the STOP key and then the DOWN key within seconds. The products can now be operated with the wall switch. max sec VELUX

Setup of wall switch KLI /2/ to operate electrical products already registered in VELUX INTEGR control pad KLR 200 The instructions below show how to copy the contents of control pad KLR 200 to wall switch KLI /2/. See also the instructions for the control pad. Important: The wall switch type must match the relevant product(s). Control pad KLR 200 to send a copy is called control. Wall switch KLI /2/ to receive a copy is called control. First execute items -5 with. Tap. 2 Tap "New product". Tap "Prepare one-way control". 4 Tap "Choose products". 5 2 Scroll down the display and choose the product to be added. Note: individual products can be identified by tapping the icon. Tap 2. You now have 0 minutes to execute item 6 with. 6 Press PIR button on for second to register the product. You can now operate the chosen product with. 7 Tap to finish. Note: To add more products, tap "Choose more" and repeat items 5-7. sec VELUX 4

Setup of a new wall switch KLI /2/ in addition to an existing wall switch KLI /2/ Important: The new wall switch must be of the same type as the existing wall switch. Existing wall switch New wall switch Prepare the product for registration by pressing the GER button on the existing wall switch for second. The product will start running briefly back and forth. 2 Press PIR button on the new wall switch for second. 2 sec sec The product can now be operated with both wall switches. VELUX 5

Setup of wall switch for group control of products Important: ll wall switches must be of the same type. Wall switches and operate separate products. The example shows how wall switch is set up to operate both products. Press the GER button on wall switch for second. 2 Press the PIR button on wall switch for second. 2 sec sec Wall switch can now operate both products. Wall switch can still operate its own product. VELUX 6

Manual operation of VELUX INTEGR roof windows GGL/GGU Manual operation of centre-pivot windows You can open and close your centre-pivot window manually. If the window is already open, you must close it fully with the wall switch first. Open the window by pulling downwards on the control bar of the window. Close the window again by pushing the control bar back again. Note: If you have opened the window manually, you must also close it manually to be able to operate it with the wall switch again. This also applies to enabling operation of programs and to ensure window closes automatically in case of rain. VELUX 7

Closing of VELUX INTEGR roof windows GGL/GGU in the case of power failure or discharged battery Manual closing without using the wall switch In case of power failure or discharged battery, you can close your centre-pivot window manually by disengaging the chain on the ventilation flap of the window. There are two ways of manual closing depending on window type. The ventilation flap can look like or. See how to disengage the chain on the ventilation flap according to your window type below. The ventilation flap of the window looks like : Disengage the chain by pressing the release clip on the flap bracket. 2 Remove the flap bracket. Fold the chain as shown, and close the ventilation flap of the window to ventilation position. 2 The ventilation flap of the window looks like : Disengage the chain by pressing the release clip on the flap bracket. 2 Fold the chain as shown, and close the window manually. 2 When the power has been reconnected or the battery has been recharged, you must re-engage the chain. Open the window manually and unfold the chain. Replace the flap bracket if the ventilation flap looks like. Run back the chain by pressing the test button on the window operator briefly. Close the window manually. VELUX 8

Closing of VELUX INTEGR flat roof window CVP without using the wall switch Flat roof windows Carefully remove the cover cap on the kerb. 2 Press the test button on the window operator behind the cover cap briefly and refit the cover cap. 2 VELUX 9