BI-680 Online Dissolved Oxygen Controller Instruction Manual

Similar documents
Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

A180 DO/BOD/OUR/SOUR Meter Instruction Manual

Bante904 Benchtop Conductivity/Dissolved Oxygen Meter Instruction Manual

WXG-4 Manual Polarimeter. Instruction Manual BANTE INSTRUMENTS CO., LTD

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

Dissolved Oxygen/Temp Waterproof Tester

Heavy Duty Dissolved Oxygen Meter

Instruction Manual HI Portable Waterproof Dissolved Oxygen Meter.

Instruction Manual DO 6. Economy Hand-held Dissolved Oxygen Meter. 68X Rev 2 Apr 08. Technology Made Easy... Part of Thermo Fisher Scientific

INSTRUCTION MANUAL. 840 Transmitter. Loop Powered Dissolved Oxygen Transmitter

Oxygen Sensor with Electrode

Instruction Manual HI Portable Dissolved Oxygen Meter. DO meter HI 8043 STB C OFF O 2 ZERO SLOPE C. ins rum n s

12mm Dissolved Oxygen Sensor Care and Use Instructions

DISSOLVED OXYGEN SENSOR BT34i

Instruction Manual DO 6+ Dissolved Oxygen/Temp

HI 9143, HI 9143M HI 9145

Dissolved Oxygen Meter. ino2. Instruction Manual. Serial No..

The Oxygen Sensor can be connected to all types of einstein Tablets, einstein LabMate, and einstein LabMate +.

PRODUCT SHEET. Order probe only as RXPROBE02

Instruction Manual. DO 700 Dissolved Oxygen/ºC/ºF Bench Meter. Technology Made Easy...

SS32L Dissolved O 2 Probe

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

Visit us at Code

MARTINI. instruments. THANK YOU FOR CHOOSING. Sales and Technical Service Contacts:

ISE-730 Oxygen Electrode and DO2-100 Currentto-Voltage

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

NEULOG OXYGEN LOGGER SENSOR GUIDE

Atlas 6TM. Indoor Air Quality Monitor Instruction Manual. Measures CO 2, Temperature and Humidity DISTRIBUTED BY

Overview. Front Panel: Keypad and Display

Optical Dissolved Oxygen Meter

RAM Operation Manual

Instruction Manual HI 9146 Dissolved Oxygen and Temperature Meter

User Manual DOCUMENT # Pro20 Pro20i USER MANUAL. English

Micro600DO_ZI INST /1/17 13:16 Page 1. Palintest. Micro 600 DO Meter. Palintest ZI INST 1240

SensoDirect Oxi200 Dissolved Oxygen Meter Operating instructions

STEAM STERILIZABLE POLAROGRAPHIC OXYGEN ELECTRODE

OWNER S MANUAL NMB SERIES

User Manual Pocket Pro + Multi 1

Installation, operating and maintenance Instructions for Seemag bypass level indicator

BUBBLER CONTROL SYSTEM

EC214 EC215 - EC215R Bench Conductivity Meters

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL -

Vinmetrica Dissolved Oxygen System User Manual

RAM 4021-DPX Operation Manual

Optical Dissolved Oxygen Meter

Portable Gas Monitor GX User Maintenance Manual (H4-0050)

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

PRO20 USER MANUAL. English. Français. Español. Deutsch

OPERATION MANUAL NTF-15

& Dissolved Oxygen Sensor. Instruction Manual

ENVIRONMENTAL INSTRUMENTS, LLC

Sensoric 4-20 ma Transmitter Board Operation Manual

Instruction Manual. PLT Series. 1. General Specification. 2. Installation. 3. Wiring. 4. Function. 5. Setting & Calibration

Dissolved Oxygen Probe (Order Code DO-BTA)

RDO Optical Dissolved Oxygen Sensor

Water Quality Monitoring Using a Handheld Sonde for in situ Measurements Date Prepared: 11/17/2017

GasSense NDIR User Manual

Dissolved Oxygen Probe (Order Code DO-BTA)

ACV-10 Automatic Control Valve

D-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA

HI 2314 HI 2315 HI 23151

Experiment C-6 Gas Solubility

Instruction Manual. Multiparameter Benchtop Meter

Short manual testo

BUBBLER CONTROL SYSTEM

RAM 4021 Operation Manual

Digital Melting Point Apparatus

Vernier Optical DO Probe (Order Code ODO-BTA)

Introduction The Smart Q Oxygen Adaptor enables an Oxygen electrode to be connected to an EasySense unit.

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

CCT-7320/ROC-2313 Reverse Osmosis Controller

QUICK START GUIDE TO DRINKING WATER MONITORING

LogIT Dissolved Oxygen Probe

OPERATING INSTRUCTIONS FOR LXT-280. Dissolved Oxygen Transmitter DANGER

O3 3E 1 F Gas Sensor Module

YSI Model 52 Dissolved Oxygen Meter

OPERATION MANUAL NTF-60 Plus

Aqua-DP. Aqua-DP Waterproof Dissolved Oxygen - ph -mv Temperature Meter. TPS Australia - Quality hand-made instruments since 1968.

STERILIZABLE DISSOLVED OXYGEN SENSORS

CDS-2000 CO 2 Sensor Verification, Calibration, and Troubleshooting Bulletin

Membrane covered optical CO 2 sensor

Columbus Instruments

Hand-held pressure calibrator with integrated pump Model CPH6600

Instruction Manual BA90 Precision Barometer

PTG100 Precision Test Gauge

Installation and Operation Manual

PERFORM Operating Document

CCS240 and CCS241. Technical Information. Sensors for chlorine dioxide Amperometric, membrane-covered sensors for installation in the CCA250 assembly

User Manual. PolyGard DT V4. Electrochemical Carbon Monoxide Transmitter Serial No. DT December, 2008

Operation Manual. Pro CO. Carbon Monoxide Analyzer. Rev

AUTOMATIC TIRE INFLATOR # MW-60, MW-60-4WAY & MW-64HP

JUMO dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO)

DPC-30 DPC-100. Reference Manual

Dissolved Oxygen OPERATING INSTRUCTIONS

Evaluation copy. Interdependence of Plants and Animals. computer OBJECTIVES MATERIALS

Transcription:

BI-680 Online Dissolved Oxygen Controller Instruction Manual BANTE INSTRUMENTS CO., LTD

BI-680 Online Dissolved Oxygen Controller 1 Introduction Thank you for selecting the BI-680 online dissolved oxygen controller. This manual provides a step-by-step guide to help you operate the meter, please carefully read the following instructions before use. Unpacking The following list describes the standard components of the controller. After the unpacking, please check all components are complete. If any are damaged or missing, please contact nearest distributor. IE-80T Industrial Dissolved Oxygen Probe Electrolyte Solution Membrane Cap Safety Warning The controller shall be installed and operated only in the manner specified in this instruction manual. Only skilled, trained or authorized person should carry out installation, setup and operation of the controller. Do not install the controller in the following environmental conditions: relative humidity is greater than 80 %, ambient temperature is higher than 60 C or strong magnetic fields around controller. The rear panel of the controller has two screw terminals that used for connecting the DC24V power supply. Make sure to cut off the main power before installation or maintenance. Once the power supply cables are connected to controller, do not touch any screw terminals on the rear panel of the controller. Installation Cut out a square hole approximately 91(W) 91(H)mm in the mounting panel. Remove the mounting bracket from controller, place the controller into the square hole. Replace the mounting bracket and push the controller forward until it is fully seated on the mounting plate.

BI-680 Online Dissolved Oxygen Controller 2 Display The BI-680 online dissolved oxygen controller is equipped with an easy-read LCD display that used to show measured values and mode icons. The following table describes the function of each icon. ICON Calibration Setup ATC ALM1 ALM2 DESCRIPTION Indicates the meter is in the calibration mode. Indicates the meter is in the setting mode. Indicates the temperature compensation is enabled. Indicates the measurement exceeded the specified high limit. Indicates the measurement exceeded the specified low limit. Keypad Information KEY FUNCTION Power the meter ON/OFF. Enters the setup menu (Press and hold the key for 3 seconds). Exits the calibration or setting and returns to measurement. Starts calibration. Increase the setting value. Sets the temperature. Decrease the setting value. Toggles between % saturation and concentration measurement modes. Confirms the calibration, settings or displayed options.

BI-680 Online Dissolved Oxygen Controller 3 Filling the Electrolyte Solution 1. Take out the dissolved oxygen probe and electrolyte solution from the packaging. Unscrew the membrane cap. 2. Fill the membrane cap halfway with electrolyte solution. 3. Screw the membrane cap onto the probe, excess electrolyte solution will drain out. 4. Be sure the cathode of probe makes contact with membrane cap, the electrolyte solution in membrane cap should be without an air bubble. Cathode

BI-680 Online Dissolved Oxygen Controller 4 Connecting the Cables Before proceeding, ensure the power supply cables are disconnected from the power source. The following list describes the definition of the each screw terminal on rear of the controller. INDEX: NO. TERMINAL DESCRIPTION 1 DO ( - ) DO input 2 DO ( + ) DO input 3 --- No connection 4 --- No connection 5 TC ( - ) Temperature input ( - ) 6 TC ( + ) Temperature input ( + ) 7 485 (B) RS485 signal output (B) 8 485 (A) RS485 signal output (A) 9 DC24 ( + ) DC24V ( + ), linear power supply #1 10 DC24 ( - ), 4~20mA DC24V ( - ), linear power supply #1, 4~20mA analog output 11 GND Earth ground 12 DC24 ( + ) DC24V ( + ), linear power supply #2 13 DC24 ( - ) DC24V ( - ), linear power supply #2 14 NC2 Relay resting position (NC2) 15 NO2 Relay working position (NO2) 16 COM2 Relay Common (COM2) 17 NC1 Relay resting position (NC1) 18 NO1 Relay working position (NO1) 19 COM1 Relay Common (COM1) 20 --- No connection DC24V ( + ), linear power supply #2 DC24V ( - ), linear power supply #2 DC24V ( + ), linear power supply #1 DC24V ( - ), linear power supply #1 Current Detection 4~20mA

BI-680 Online Dissolved Oxygen Controller 5 Setup Menu The BI-680 online dissolved oxygen controller contains an integrated setup menu that is used to customize the displayed option to meet measurement requirements. The following table describes the functions of the menu items. MENU DESCRIPTION OPTIONS DESCRIPTION DEFAULT Set the salinity coefficient Range: 0~35ppt 0.0ppt Set the barometric pressure coefficient Range: 450~850mmHg 760mmHg Set the number of calibration points Set the default measurement unit 1 point 2 points mg/l Concentration Unit ppm Concentration Unit % % saturation Degrees Celsius Degrees Fahrenheit 1 point mg/l C Set the Low Alarm Limit Range: 0.00~20.00mg/L 4.00mg/L Set the High Alarm Limit Range: 0.00~20.00mg/L 10.00mg/L Set the hysteresis value Range: 0.01 ~0.10mg/L 0.1mg/L Set the analog output (low) Range: 0.00~20.00mg/L 4.00mg/L Set the analog output (high) Range: 20.00~0.00mg/L 10.00mg/L Reset Restores the controller back to factory default settings Disable Disable Additional information Select a High/Low limit setting value will activate the controller when the measuring value goes above or below the setting value. Note, both setting values cannot input the same value. Hysteresis prevents rapid contact switching if the measuring value is fluctuating near the set point. Example: You have set the high alarm point at 20.00mg/L and hysteresis value at 0.1mg/L. If the measuring value overshoots the 20.1mg/L, the controller will activate an external device. When the measuring value drops to 19.9mg/L, the external device will switch off. The controller has RS485 communication function, the default is 4.00~10.00mg/L corresponds to 4.00~20.00mA. Reset function will restore the controller back to factory default settings, all calibration values and selected parameters will be reset.

BI-680 Online Dissolved Oxygen Controller 6 Setting the default option 1. Press and hold the key for 3 seconds to enter the setup menu, the display shows the menu item and page number. Menu item Page number 2. Press the or key to scroll through menu, select the parameter you want to set (Refer to Setup Menu). 3. Press the Enter key, the display shows an option in the submenu. 4. Press the or key to set the value or select an option. 5. Press the Enter key to confirm, the controller returns to the measurement mode. Setting is completed. If you want to exit the setting, press the key. Temperature Compensation and Calibration The BI-680 online dissolved oxygen controller supplied with an industrial DO probe with a built-in temperature sensor. When the wires of the sensor are connected to controller, the display will immediately show ATC icon. The controller is now switched to automatic temperature compensation mode. ATC Temperature calibration During the measurement process, if the temperature reading displayed differs from that of an accurate thermometer, the controller needs to be calibrated. 1. Press the o C key to enter the temperature setting mode, the display shows current temperature reading. 2. Press the or key to set the value. 3. Press the Enter key confirm. Calibration is completed.

BI-680 Online Dissolved Oxygen Controller 7 DO Calibration in % Saturation Mode The BI-680 online dissolved oxygen controller is able to perform either 1 or 2 points calibration in the dissolved oxygen mode. For single point calibration, we recommend that you perform 100% saturation calibration in the air-saturated water. If the 2 points calibration is selected, the zero oxygen solution needs to be used. Single point calibration - 100% saturation 1.1 Make sure that you have selected 1 point calibration in the setup menu. 1.2 Connect the dissolved oxygen probe to controller and wait for 15 minutes to polarize the probe. 1.3 Press the Cal key, the controller shows CAL1/100%. 1.4 Hold the dissolved oxygen probe in the air at 100% relative humidity or place the probe into the air-saturated water for 15 minutes. Press the Enter key. Wait for the reading to stabilize, the display automatically shows END. Single point calibration is completed. 2 points calibration 2.1 Make sure that you have selected 2 points calibration in the setup menu. 2.2 Repeat steps 1.2 to 1.4 above. When the first calibration point is completed, the display will show CAL2/0%. The controller prompts you to continue with second point calibration. 2.2 Immerse the dissolved oxygen probe into the zero oxygen solution for at least 10 minutes, press the Enter key to begin the calibartion. Wait for the reading to stabilize, the display automatically shows END and returns to the measurement mode. Calibration is completed. Performing a percentage saturation calibration will simultaneously calibrate the corresponding mg/l (or ppm) concentration value. Therefore, additional mg/l calibration isn t required in most circumstances. During the calibration process, press the key, the controller will exit the calibration and return to the measurement mode.

BI-680 Online Dissolved Oxygen Controller 8 Measurement The BI-680 online dissolved oxygen controller is suitable for measuring the water, wastewater, brine and other liquids. If the sample is belong to the seawater or other water containing large amounts of salt, please setting the salinity coefficient before measurement. Some gas and steam such as chloride, sulfur dioxide, sulfureted hydrogen, ammonium, carbon dioxide and iodin can permeate the membrane via diffusion. So their existence will influence the measurement of dissolved oxygen. If the sample contains the solvent, grease, sulfide and alga, the membrane on the probe will be blocked, damaged or eroded. 1. Connect the dissolved oxygen probe to controller and wait for 15 minutes to polarize the probe. 2. If necessary, to set the barometric pressure and salinity coefficient in the setup menu (Refer to Setup Menu). 3. Immerse the probe in the sample solution, make sure the temperature sensor on the probe is fully immersed. 4. Stir the probe gently. Record the measured value when the reading is stable. Temperature Sensor Dissolved Oxygen Probe Care and Maintenance Always keep the membrane of the dissolved oxygen probe is wet or moist. If you do not use the probe for long periods, please screw off membrane cap and rinse the cathode, anode and membrane with deionized water, then soak up residual water on them with filter pape. Install the probe again. Membrane cap Cathode and Anode Troubleshooting LCD DISPLAY CAUSE CORRECTIVE ACTION Measured value is out of range Electrolyte solution is depleted Zero oxygen solution is contaminated Check the DO membrane whether clogged, dirty or broken Refilling electrolyte solution Replace the calibration solution

BI-680 Online Dissolved Oxygen Controller 9 Specifications Dissolved Oxygen % Saturation of Oxygen Transmitter Function General Model BI-680 Range 0.0~20.0mg/L Accuracy ± 0.5mg/L Resolution 0.1mg/L Range 0.0~200.0% Accuracy ± 2.0% Resolution 0.1% Signal Output 4~20mA Load 500Ω Low and high alarm limits 0.00~20.00mg/L, Selectable Communication Interface RS485 Temperature Compensation 0~40 C, 32~104 F Barometric Pressure Correction 60.0~112.5kPa, 450~850mmHg Salinity Correction 0~35g/L Power Requirements DC24V Ambient Temperature < 60 C Relative Humidity < 80% Dimensions 96 (L) 96 (W) 75 (H)mm Weight 350g

BI-680 Online Dissolved Oxygen Controller 10 Addendum 1: Pressure VS Altitude Table ALTITUDE (m) kpa mmhg ALTITUDE (m) kpa mmhg 0 101.3 760 1600 82.9 622 100 100.1 750 1700 81.9 614 200 98.8 741 1800 80.9 607 300 97.6 732 1900 79.9 599 400 96.4 723 2000 78.9 592 500 95.2 714 2100 77.9 584 600 94.0 705 2200 76.9 577 700 92.8 696 2300 76.0 570 800 91.7 688 2400 75.0 563 900 90.5 679 2500 74.1 556 1000 89.4 671 2600 73.2 549 1100 88.3 662 2700 72.3 542 1200 87.2 654 2800 71.4 536 1300 86.1 646 2900 70.5 529 1400 85.0 638 3000 69.6 522 1500 84.0 630 3100 68.7 515 Addendum 2: Preparation of the Zero Oxygen Solution Dissolve 500mg of sodium sulfate (Na2SO3) reagent and a small amount of cobalt(ii) chloride hexahydrate (CoCl2 6H2O) in the 250mL distilled water, mix the solution until the reagent is completely dissolved.

Hazardous Substance Statement Bante Instruments is committed to the reduction and eventual elimination of all hazardous substances in both the manufacturing process and finished products we supply. We have an active manufacturing and procurement program to minimize and eliminate the use of harmful heavy metals such as cadmium, lead, mercury and the like. New technologies and design parameters are also promoting these efforts and we expect to have little or no such materials in our product in the coming years. We welcome our customer suggestions on how to speed up these efforts. Warranty The warranty period for controller is one year from the date of shipment. Above warranty does not cover the sensor and calibration solutions. Out of warranty products will be repaired on a charged basis. The warranty on your controller shall not apply to defects resulting from: Improper or inadequate maintenance by customer. Unauthorized modification or misuse. Operation outside of the environment specifications of the products. For more information, please contact the nearest authorized distributor. BANTE INSTRUMENTS CO., LTD E-mail: banteinstruments@yahoo.com Phone: +8621-6404-1598 Website: www.bante-china.com The information in this document is subject to change without notice. Copyright Bante Instruments, 2018. All rights reserved.