Myfuser SILICONE ELASTOMERIC PUMP. basic information

Similar documents
Making Life Easier Easypump II

Clinician Guide. Baxter Elastomeric Devices. Promoting patient-centric care

EASYPUMP II THE FLEXIBLE SOLUTION FOR SHORT AND LONG TERM INFUSION THERAPIES

CYTO. Safe Preparation and Administration of Cytostatics

Volumat Agilia _Volumat_Presentation_customer.ppt

BODYGUARD 2CH TWIN CHANNEL INFUSION PUMP

New. The high security connection

NEXUS TKO. Specialty Neonatal/Pediatric. Safety Infusion Sets. Blood Reflux Protection 24/7! Anti-Reflux Technology Provides

Infusion. 1 evercare inline

C O L O G Y. New. g u O N. l o t a C a. The high security connection

Tourniquet Systems Pressure Infusion

Compatible Baxter IV Sets

PUMP WITH FIXED FLOW RATE. Instructions for Use

HEALTHCARE PROFESSIONAL GUIDE. Elastomeric Products

Huber needle EZ Huber JetCan. Quality and Experience

V-Green Protect-A-Line A range of drug-compatible extension lines designed to enhance patient safety during IV therapy.

INTERVENTIONAL CARDIOLOGY

Alaris Pump module FAQs

PRODUCT CATALOGUE OF

Blood Pressure Monitoring: Arterial Line

Patients Guide for Self Administering Intravenous Antibiotics General points

InFlow Modular perfusion bioreactor

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

DIAGNOSTIC CARDIOLOGY

Multi Channel Solutions

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

Valve with Integrated Pressure Regulator for medical OXYgen

CRONO S-PID 30 Ambulatory infusion pump

Filtration FILTRATION PRODUCT TIPS

Unity Sleeveless Elevated Vacuum System

DONOR TM Pre-Evacuated Post-Operative Autologous Blood Reinfusion System

Haemodialysis. Bloodlines, Tubing Systems, Accessories Product Range. Product name / Headline Subline

A complete family of Pediatric Perfusion Systems

CHEM 355 EXPERIMENT 7. Viscosity of gases: Estimation of molecular diameter

THE UNIVENTOR 400 ANAESTHESIA UNIT

Variable Area Flow Meters

An Overview of Types of Isolation Valves

CADD-Micro. Model 5900 Operator s Manual. Note: Colors are Black and Cyan (as second color) Deltec. Ambulatory Infusion Pump

Introduction. Medley TM Medication Safety System. Alaris Medical Systems

Patient Guide. Baxter Elastomeric Devices. Promoting patient-centric care

Safety Huber Needles

CLEAN ROOM Innovation applied to sterilizable devices

ERKA Profi impact-resistant based on internationally recognised standards such as ANSI/ AAMI SP 10.

Digital Display large color coded LED display is easy to read precise measuring shows actual cuff pressure

Chest Drainage Systems for Cardiac & Thoracic Surgery. Including portable suction with Digital Air Leak Monitoring

AUTOVENT 4000 VENTILATOR


The Univentor 1250 Anaesthesia Unit

BIOCLOSURE SYSTEM ASSEMBLIES

ACCURACY, PERFORMANCE, AND HANDLING OF OIL-FILLED DIGIQUARTZ PRESSURE INSTRUMENTATION

Full-Vacuum Chlorinator C 2212 MB / 1

Experiment 18 Properties of Gases

Bloodlines, Tubing Systems, Accessories

MoveRoll Conveyor Operating and Maintenance Manual

aeration and mixing systems

Diacan and Diacan S. The safe and gentle vascular access for dialysis

IDEAL FOR SHORT- TO MEDIUM- TERM ANAESTHESIA OR VENTILATION. Anaesthesia Tracheal Tubes

TUBINGS / CONNECTION PIECES

Aseptic Techniques. Techniques for Sterile Compounding. Pharmacy Technician Training Systems Passassured, LLC

Contacts. Quick Start Guide

Columbus Instruments

29 Pressure, Temperature relationship of a gas

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

AQUADEX FLEXFLOW SYSTEM QUICK REFERENCE GUIDE

Assisting with Insertion. Care of Intraspinal Catheters

The FreedomEdge is not intended for the delivery of blood, critical* or life-sustaining medications, or for the infusion of insulin.

User s Guide. CO2 Controller for miniature incubators

Digital Tourniquets. Product Details. For electricity VAC, 50/60 Hz

MIC *, MIC-KEY * GASTRIC-JEJUNAL (GJ) FEEDING TUBE PATIENT USE & CARE GUIDE

Instructions For Use. Elastomeric Infusion Device

BS ml Bottle Sampling Unit

User Manual MFCS TM -EZ

Ambulatory infusion pump USER GUIDE

O2100C Oxygen Measurement Module Technical Use Notes do not use other wall adapters with the O2100Cmodule. 10% / V 5% / V 2% / V 1% / V 10% / V

CONTENTS DESCRIPTION INTENDED USE. WARNINGS & NOTES. PRECAUTIONS. INSTALLATION & SET-UP (Including battery charging & powering up)

Unit 2 Kinetic Theory, Heat, and Thermodynamics: 2.A.1 Problems Temperature and Heat Sections of your book.

Nursing Guide Portsystems

Syringe, Distribution Valve and Infusion Pump Removal/Replacement ATTENTION SYRINGE REPLACEMENT

PAIN RELIEF SYSTEM PATIENT GUIDELINES

differential pressure regulating valve - threaded

UNITS /2017-E ENDOFLATOR 50. The New High-Performance Insufflator with Integrated Heating Element from KARL STORZ

DISSOLUTION TEST FOR SOLID DOSAGE FORMS

Klinik ERKAmeter base model with rail holder, available separately.

4-7 kw/ hp. Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward

WE CARE ACCURATELY. ACCURA Medizintechnik GmbH Max-Planck-Straße Karben / Germany Tel:

HONG KONG COLLEGE OF ANAESTHESIOLOGISTS TECHNICAL GUIDINES RECOMMENDATIONS ON CHECKING ANAESTHESIA DELIVERY SYSTEMS

FLOWMETER UNITS FLOWMETER DEVICES, BY-PASS SYSTEMS

Accelerated Corrosion Test Chambers

NanoSight NS300. NanoSight NS300. Operation instructions. Laser Spectroscopy Labs, UCI

Glass tube flowmeters Series 2000

INFUSION SYSTEM (110V) (220V) USER S MANUAL

PATIENT USER GUIDE CANÈ

Quiz for Module 2: Aquarius Training (Rev. 1) Lesson 1: Introduction to Aquarius

Art PRESSURE REDUCER

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

Exploring the Properties of Gases

VIC offers a variety of Calibrated Gas Leaks

Benefits. Rev.III_032018_Oxybaby 6.0_engl subject to technical alterations

Varithena Delivery System Instructions for Use INSTRUCTIONS FOR USE Please read the Product Monograph before using the product.

Information for patients and nurses. Rocket Ambulatory Chest Drain

Transcription:

Myfuser SILICONE ELASTOMERIC PUMP basic information

> Myfuser...a brief presentation! MYFUSER is an elastomeric, disposable infusion pump for administration of various drug solutions without the need of batteries or power supply. In fact an internal balloon, in medical grade silicone material, is able to contain the solution and, thanks to its own elasticity, to push it through a filtering system into the infusion line down to the patient. The infusion rate is controlled by a flow restrictor capillary positioned inside the distal connector. The quantity of milliliters delivered over a time unit (flow rate ) depends on the following variables: P r 4 pressure differential (p1-p2) (P1 pressure in the balloon, P2 counter pressure of the patient s system ) tube radius to the fourth power (in this particular case the radius of the flow restrictor) solution viscosity (viscosity of the final solution to infuse) infusion line lenght (in this particular case, the length of the glass flow capillary) T temperature (at level of flow restrictor capillary) Hagen Poiseuille phisic law: = (short form) P r 4 K (T ) MAIN DRIVERS (VARIABLES): TEMPERATURE PRESSURE VISCOSITY 1 C variation causes up to 2% of flow variation (directly proportional) 10 cm of H 2 O variation causes up to a 3% di of flow variation (directly proportional) Myfuser is calibrated with NaCl 0.9% (for deferoxamine, a high viscosity drug, special models are available) (indirectly proportional variation) > filling the pump with high concentration solutions (like hypertonic dextrose) will decrease the flow rate significantly. 2

> why Myfuser? DOCTOR NURSE INFUSION PATIENT EFFICIENCY SAFETY COMFORT PRACTICALITY 1. EFFICIENCY 2. SAFETY 3. COMFORT 4. PRACTICALITY > 1. efficiency: IT ALLOWS CORRECT THERAPY IN TERMS OF DURATION AND FLOW RATE distal connector in section > Myfuser flow restrictor capillary is obtained from high quality GLASS of German production. Our technical personnel is engaged in constant control of each single flow restrictor before being assembled in Myfuser. The choice of a glass capillary is justified by the mechanical properties of this material, particularly suitable for a precise and high quality manufacturing process, even at minimal dimensions, and allowing minimal variations in presence of temperature variations (as an example, hard PVC modifies its dimensions 27 times more than borosilicate glass at the same temperature variation). > apply and maintain the distal connector in contact with the patient s skin. 3

> 1. efficiency: Simulation of dimensional variation by temperature increase. The increased diameter of the capillary could cause a significant flow variation (see the r 4 Hagen Poiseuille law) > High quality medical grade silicone, manufactured in the USA, is used to produce the elastomeric balloon. Every single balloon is controlled for push pressure before it is assembled. Small variations of the expected pressure values will be absorbed by the capillary length s adjustment. Push pressure variations during infusion are controlled thanks to the presence of a mobile piston sliding along the fix rod, ensuring a symmetrical and uniform filling and deflation of the balloon. PSI PRESSURE GRAPH ml/h FLOW GRAPH HOURS HOURS These features and the quality controls minimize the effects of pressure modification on the flow rate, thus ensuring constant pressure and, consequently, the best conditions for a correct implementation of the therapy (see p1 variable in the Hagen Poiseuille law). > it is recommended to keep the balloon and distal connector always at the same level. 4

> 2. safety: TO PREVENT POSSIBLE DANGEROUS EVENTS FOR PATIENTS AND OPERATORS > Rigid, crush-proof container, made of high quality material, protects the ballon from direct accidental pressures. Extra-pressures could cause the balloon explosion with consequent potential damages to medical operator or to patient or, alternatively, dangerous increase of the flow rate. > Filling port, equipped with a special anti-reflux valve and with an internally fitted 200 micron filter, which prevents foreign particles, such as plastic or glass fragments originated during drug which reconstitution or collection, from entering into the system. > Double membrane filtering system (0.02 micron hydrophobic filter for automatic air expulsion from the system, and 1.2 micron hydrophilic antiparticulate filter), placed at distal end of tubing to clean the solution right before entering the glass capillary and, therefore, the patient. (see product general overview in the central pages) > Anti-kinking tube, to prevent accidental interruption of the infusion. > The specific removable clamp ensures the voluntary and controlled interruption of the infusion. This is particularly important during connection of the device to the patient: an open flow could cause dripping of the drug on the patient s skin or on the operator s fingers. (see product general overview in the central page). > Myfuser is a completely close and pre-assembled system. This reduces the number of manual operations during preparation and prevents risks of mistakes, breakage and contamination. 5

> 2. safety: BIOCOMPATIBILITY AND DRUG STABILITY Relative to compatibility and drug stability, Myfuser offers the best guarantiees thanks to high quality materials used for the various parts of the pump. In particular it should be considered the medical grade silicone (Dow Corning USA) for its well known biocompatibility and chemical inertia. In addition, Myfuser components are Latex-free and phthalate-free (DEHP). Myfuser has been successfully tested for: cutaneous reaction ISO 10993-10 cytotoxicity ISO 10993-5 haemolysis and haemocompatibility ISO 10993-4 systemic acute toxicity ISO 10993-10 allergic sensitization ISO 10993-10 Furthermore, Myfuser has been tested for drug compatibility and stability with the most frequently used drugs: 5 Floruracil Cytarabine Methotrexate Sodium Mitoxantrone Hydrocloride Vinblastine sulphate Tramadol Ketorolac Fentanyl Morphine Bupivacaine Ropivacaine Ceftazidime Desferrioxamine Metoclopromide Odansetron Hydrocloride Ranitidine et al. The experimental reports on the various tests performed in cooperation with the Bari University, Pharmacy Pharmaceutical Science Department are available on request. > 3. comfort: LIGHT AND EASY TO WEAR > With its ergonomic design and reduced dimensions, Myfuser is a light, resistant and easily portable device. 6

> 4. practicality: EASY TO USE AND HANDLE > Reduced dimensions, minimal space, easy to store. > The filling port can be laid down on the working surface for easy filling operations. > Setting up and priming the device is made simple and fast by a distal vented cap with hydrophobic filter membrane. This membrane allows the complete and automatic expulsion of the air from the device eliminating the need of unscrewing the cap and opening the system. > Myfuser offers the possibility of a detailed and constant visualization of the infusion progress, by means of a graduated scale magnified by a lens incorporated in the external case (see product general overview in the central pages). > Easy to fill (presently the lowest force to be applied on the syringe piston). FORCE TO BE APPLIED (measured by dynamometer) model volume force S 60 ml 4.2 Kg ca. M 100 ml 4.3 Kg ca. XM 120 ml 4.3 Kg ca. L 275 ml 4.5 Kg ca. 7

DOUBLE MEMBRANE DISTAL FILTER it expels possible air bubbles and filters the liquid before it enters the capillary antiparticulate membrane: 1.2 micron air-venting membrane: 0.02 micron FLOW RESTRICTOR DISTAL CONNECTOR flow regulator with high quality internal glass capillary (element in section) DISTAL VENTED CAP WITH HYDROPHOBIC MEMBRANE it facilitates, keeps sure and speeds up the preparation and priming of the device

GRADUATED SCALE It allows an easy monitoring of the infusion progress by means of an incorporated magnifying lens PISTON the balloon s guide and support system (mobile piston and fix rod) facilitate the filling and deflation phases, preventing the risk of explosions and ensuring constant pressure throughout the infusion process SILICONE BALLOON it pushes the liquid down the infusion line. It guarantees biocompatibility, chemical inertia and transparency RIGID HOUSING it protects the silicon balloon from accidental external pressure and prevents breakage FILLING PORT supplied with female luer lock connector, anti-reflux valve and 200 micron filter REMOVABLE CLAMP it allows voluntary interruption of the infusion. It can be completely removed, if necessary PCA MODULE it allows additional administration of a bolus to the patient by pressing the button

> where is Myfuser used? MYFUSER IS USED IN 4 MAIN CLINICAL AREAS FOR HOSPITAL AND HOME CARE TREATMENTS 1. anesthesia INFUSION OF ANESTHETIC/ANALGESIC DRUGS FOR PAIN TRE ATMENT: > Post-operative, acute pain management. It is performed intravenously, epidurally, through brachial plexus or intralesionally (LRA). > Long term pain management: treatment of chronic pain and palliative therapies. It is normally performed intravenously or subcutaneously. 2. oncology INFUSION OF CHEMOTHERAPEUTIC DRUGS: > Cytostatic drug infusion to hospitalized patients and/or under home care treatment through peripheral venous catheters or central venous catheters (Port CVC). 3. antibiotic and antiviral therapy > Short infusions > High drug doses > Frequent treatments INFUSION OF ANTIBIOTICS AND ANTIVIRAL DRUGS USUALLY REQUIRES: Specific Myfuser models guarantee the following high flow rates: 50, 100, 200 and 250 ml/h 4. thalassemia THALASSEMIC PATIENTS REQUIRE IRON CHELATING TREATMENTS AMONG WHICH THE INFUSION OF DEFEROXAMINE (DESFERAL-DFO). THIS DRUG HAS A HIGHER VISCOSITY THEREFORE DEDICATED MODELS OF MYFUSER ARE PRODUCED FOR ADMINISTRATION OF DFO IN THALASSEMIC THERAPY: > F0010S*DFO, 60 ml volume, 1 ml/h flow rate > F0020S*DFO, 60 ml volume, 2 ml/h flow rate > F0050S*DFO, 60 ml volume, 5 ml/h flow rate It is generally applied intravenously or subcutaneously. 10

> summarizing MYFUSER CAN BE USED IN THE FOLLOWING WAYS OF ADMINISTRATION: 1. Peripheral I.V. 2. Central I.V. 3. Intra-arterial 4. Subcutaneous/intramuscular 5. Spinal (subarachnoid) 6. Epidural (peridural - extradural) 7. Intralesional/through brachial plexus 11

> for the best use of myfuser > Duration of infusion depends on the filling volume and flow rate of the pump used (see table below). FOO20S nominal volume 60 ml flow rate 2.0 ml/h duration 30 h (60/2= 30) filled volume flow rate duration 48 ml 2.0 ml/h 24 h FOO50L nominal volume 275 ml flow rate 5.0 ml/h duration 55 h (275/5= 55) filled volume flow rate duration 240 ml 5.0 ml/h 48 h > Filling Volumes The flow accuracy is ensured even if the balloon is partially filled. The expected variation is + 5-7% in case of filling up to 80-60% of the nominal volume (in case of filling lower than 60% the expected variation is over 10%). nominal volume max volumes S 60 65 M 100 105 XM 120 130 L 275 300 > Remember to keep Myfuser always at the same level of the distal connector. ml/h balloon and capillary at the same level HOURS ml/h balloon 0.5 mt above capillary faster infusion HOURS ml/h balloon 0.5 mt below capillary slower infusion HOURS > 1 meter gravitational difference can modify the flow rate up to +/- 50% 12

> Keep the distal connector always in contact with the skin. The flow restrictor capillary is calibrated at an internal working temperature of 31-32 C (i.e. skin temperature less ~ 5 for thermal dispersion). The combination of the property of the glass capillary (no dimensional variation upon temperature variation) and the temperature stabilization consequent to the contact with the skin, are the best conditions for a precise flow. > Refrigerated drugs should be brought to room temperature before use. The same applies to Myfuser device, if kept in the refrigerator: this will avoid appearance of water condensation droplets inside the pump and lower flow rate. > which Myfuser? MYFUSER TO SATISFY ALL NEEDS TYPES flow rate CONTINUOUS INFUSION flow rate CONTINUOUS PLUS BOLUS flow rate ONLY BOLUS bolus bolus time lockout time time lockout time time MODELS Available volumes: 60 ml, 100 ml, 120 ml e 275 ml Available flow rates: 0.5 1 1.5 2 2.5 4 5 8 10 13 ml/h Available bolus sizes: 0.5, 1 e 2 ml Lock-out time: 8, 15, 30 e 60 minutes VOLUMES 60 ml 100 ml 120 ml 275 ml 13

> wrapping up! THE SIMULTANEOUS PRESENCE OF THE FOLLOWING SPECIAL FEATURES RENDERS MYFUSER THE IDEAL SOLUTION FOR INFUSION TREATMENTS: 1. Rigid external housing, crush-proof and transparent, allows immediate visual inspection of the content, and prevents flow rate variations caused by accidental external pressures. 2. Incorporated belt clip (for 60 100 and 120 ml pumps), rendering the device easily portable to the patient s comfort. 3. Medical grade silicone balloon: entirely latex-free, transparent and chemically inert. 4. Internal sliding piston, with supporting rod: it determines a constant flow, thanks to the progressive and uniform deflation of the balloon during infusion. The system allows the infusion also with partial filling volumes. 5. Glass flow restrictor capillary: the glass ensures a smooth, clean internal wall and constant dimensions in case of thermal variations. 6. Anti kinking tubing of the IV line: made in TOTM-PVC, 100 cm long, it prevents accidental interruption of the flow. DEHP FREE, LATEX FREE 7. Distal filtering system: composed of antibacterial and antiparticulate hydrophilic filter 1.2 µm, and hydrophobic filter 0.02 µm for automatic air expulsion. It ensures high safety standards. 8. Filling port filter: placed inside the filling port; by means of a 200 µm membrane it prevents the entry into the system of macro drug precipitates, plastic particles or glass fragments originated during preparation of the drugs product. 9. Filling port: provided with anti-reflux valve and support base, for easier and more comfortable filling procedure. 14

10. Residual volume: extremely low, less than 3 ml (tube included). 11. Pre-Assembled and close system: it reduces the number of manual operation during preparation and prevents the risk of mistakes, breakage and contamination. 12. Removable Clamp: maintaining the anti-kinking properties of the tubing it allows the voluntary interruption of the flow to easily and safely connect the device to the patient, avoiding dripping of the drug, and to control the initial phase of infusion. 13. Volume, flow rate, and batch number: are clearly indicated on each single package (pouch), and also on the device housing. 14. Infusion progress monitoring system: composed of a graduated scale* with values expressed in ml, and specific magnifying lens (for 60, 100 ml and 120 ml pumps) incorporated in the device s housing. *Purely indicative measuring tool 15. Product range: it provides a wide choice of options among volumes, flow rates and PCA applications. 16. Flow rate indication in ml/hour: printed on the device s housing as well as on the distal connector for a final verification while connecting the system to the patient. 17. Distal vented cap with hydrophobic membrane: it makes the preparation and the priming of the device easy, rapid and safe. 18. Flow rate accuracy: +/- 10% in all models. 19. Color code: a colored band on the distal connector indicates the specific flow rate color code and the respective value in ml/h. 20. Anti UV filter: a special filter inside the polycarbonate housing provides protection from UV rays (up to 380 nanometers) to photosensitive drugs, though preserving the absolute transparency of the container. 15

CANOX M.D. CANOX MEDICAL DEVICE SRL Headquarters via Cristoforo Colombo s.n. ZI 70010 Capurso (Bari) Operations Dept. Strada per Vienna 9 34151 Opicina (Trieste) ph +39 040 215162 fax +39 040 9772089 www.canox.it myfuser@canox.it The image of Myfuser on the cover is in real scale.