Diamond 8 Plus. Alternating + Micro Low Air Loss Pressure Relief System. User Manual. Distributed by: Quart Healthcare Inc.

Similar documents
(DynaLaL III) Dynamic True Low Air Loss Mattress Replacement System

Operation Manual. H & R Healthcare 1750 Oak Street Lakewood, NJ Phone: Fax:

Med Aire Alternating Pressure Pump and Pad System

Alternating Pressure / Low Air Loss Mattress System

Instruction Manual for Configura Cushionair Portable Pump

SELECT SERIES LS200 ALTERNATING PRESSURE / LOW AIR LOSS MATTRESS SYSTEM

Paradise Pump Series Operator s Manual

USER MANUAL. AltaDyne XT Model A AltaDyne XD Model A Alternating Pressure / Low Air Loss Replacement Mattress System

Air Plus User Manual

Pegasus Aircare Mattress Overlay System Models 2200 and 2201

User Manual. 10. Dimensions and Ordering Codes. Integrity Alternating Pressure Mattress System. Alternating Pressure Mattress Systems

Contents. Introduction...1 About Breeze... 1 Breeze Overlay... 2 Breeze Mattress Replacement... 2 Breeze Pump... 4 Controls and Indicators...

Operator s Manual. Dynamic Low-Air-Loss Therapy with Alternating Pressure

User Guide Antidecubitus systems EURO BASIC

User Manual. soft air simplex wds. Health. Security. Independence. Pressure ulcer prevention and treatment-system Assembly and Operation instructions

SELECT SERIES LS300 ALTERNATING PRESSURE / LOW AIR LOSS MATTRESS SYSTEM

APH166 Morpheus Air USER MANUAL. Apollo Healthcare Technologies Ltd. Holme Street, Liversedge, West Yorkshire, WF15 6JF.

770000S CLINICAL MAX LOW AIR LOSS WITH ALTERNATING PRESSURE SYSTEM USER MANUAL

MA90 Series Mattresses. MA95 Series Mattresses

AltaDyne AutoFloat. Alternating Pressure Management Plus. Model # Model # OPERATORS MANUAL

Use this key to determine which sections of this Product Manual apply to your job.

Key Product Features. Primary Use: Aggressive Treatment of Pressure Ulcers

USER MANUAL SAVE THESE INSTRUCTIONS. For the most current manual revision, please visit our Website:

Concentrate Distribution System (Stand Mounted) A-CDS-70-X & A-CDS-TANK-X-ST Industrial Drive, Orlinda, TN 37141

POWERPRESS UNIT. User Manual. Gradient Pneumatic Sequential Compressor. Neomedic

User Manual soft air wds

SC505 Sof Care Inflator. Operating Instructions and Service Manual

User Manual DIRECTHEALTHCARESERVICES.CO.UK

MA60 Series. MA60 Alternating Pressure System. MA65 Alternating Pressure On-Demand Low Air Loss System. Owner s Operator and Maintenance Manual

Panacea AIR PRO MATTRESS. Owner s Manual. Please keep and refer to this Owner s Manual.

AIR COMPRESSOR 12 V DIRECT DRIVE MULTI-FUNCTION INSTRUCTION MANUAL. Model no

User Manual. This manual MUST be given to the user of the product. BEFORE using this product, read this manual and save for future reference.

User Manual DIRECTHEALTHCARESERVICES.CO.UK

VERTICAL AIR COMPRESSORS

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

VERTICAL AIR COMPRESSORS

microair MA65 Series Alternating Pressure Low Air Loss Mattress User Manual MA65, MA65B42, MA65B48, MA65RSR

Vevazz. Operation Manual. Vevazz, LLC Rancho California Road. Suite Temecula, CA Phone: (773) Fax: (888)

LOGIC RANGE AUTOMATIC PRESSURE

MODEL 100 NITROGEN INFLATION CART

Portable oxygen concentrator

PRESSUREGUARD APM OWNER S MANUAL. PressureGuard APM Bariatric. Span-America Medical Systems, Inc. Greenville, SC

DYNAMIC COMPRESSION THERAPY

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

Operators Manual. Supera Wall Mount Anesthesia Machines. Models: M2300 M2500. (All shown with optional equipment) M2300 M2500

User manual. MNPG 102 Rev. 04 Edition 04/02/16. Pressotherapy model. Power-Q1000 Premium

77-I0PN230 Rev. A. Model 1030 User Manual

USER MANUAL SAVE THESE INSTRUCTIONS. 300 Held Drive Tel: (+001) Northampton, PA USA Fax: (+001) ISO Certified

User manual STARLOCK. Careways International - Innovation Quality Performance

English USER GUIDE User guide

Regalia Oxygen Concentrator

TWIN CYLINDER RAPID INFLATOR With Direct Battery Connection

U S E R M A N U A L. Model: PM4300 Series SAVE THESE INSTRUCTIONS

Introduction. Table of Contents. Automatic Wrist Blood Pressure Monitor With Voice-Guided Operation. Model No.: BP5K

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

MODEL Maverick Heavy Duty Aerosol Compressor Operator s Manual

Lateral Turning System. User Guide.

COMPRESSOR AND INFLATOR WITH TORCH

RAM 4021 Operation Manual

Dynamic pressure system for pressure relief

Oxygen Concentrator Instruction

1 METRON MANIPULATION TABLES - WARRANTY STATEMENT

NIMBUS range. with people in mind

Welcome to the World of In-Home Gardening! Simple Steps to Get Your AeroGarden Up and Growing (No Tools Required)

VENTI-O 2 plus. O 2 switching valve for: VENTImotion from serial number 4000 VENTIlogic from serial number 4000 VENTImotion 2

Nitrogen Supply System

Operating Instructions Part No

INFLATION STATION. Cordless OWNER S MANUAL MODEL NO: RCP-C65B

NIMBUS 4 NIMBUS PROFESSIONAL

AUTOVENT 4000 VENTILATOR

Digital Melting Point Apparatus

SALISBURY ACTIVE OVERLAY SYSTEM

Manual for HoverJack Devices

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

Leglifter. user instructions. Simple solutions for everyday independence

30000 Series Treatment Tables

PETERSEN 161-SERIES HIGH PRESSURE LIFTING AIR BAGS OPERATING INSTRUCTIONS WARNING!

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

M5400 Operators Manual

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

User Manual DIRECTHEALTHCARESERVICES.CO.UK

Pressure Automated Calibration Equipment

200 PSI HIGH-FLOW AIR SOURCE KIT

200 PSI FAST-FILL AIR SOURCE KIT

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

User Manual. Version 1.2 July 2015 Pg. 1

Operating Instructions Part No

Dual Release Walkers 6291 Series. 1 General. 1.1 Symbols WARNING

LYMPHA PRESS MANUFACTURED BY MEGO AFEK IMPORTED BY LYMPHA PRESS USA, Ltd. USERS MANUAL LYMPHA PRESS MODEL 201-M

EasyFit Lite Nasal Mask, Silicone. Nasal Mask. EasyFit Lite Nasal Mask. Device Description and Instructions for Use. Caution:

AKRON CHILDS TILT TABLE

Intermittent Pneumatic Compression System

COMPACT AIR COMPRESSOR MODEL NO OWNER S MANUAL

Instructions for Cleaning & Maintaining Air Compressor

Budget Range Operators Handbook

Micro Dial-Flowmeter. Instructions for Use

OC4000 USER'S GUIDE I O OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY. by Supera Anesthesia Innovations GLOSSARY OF SYMBOLS. : ON (power switched on)

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

OC4000 USER'S GUIDE I O OXYGEN CONCENTRATORS OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY GLOSSARY OF SYMBOLS. : ON (power switched on)

How did we design such a revolutionary alternating pressure mattress system?

Transcription:

Diamond 8 Plus Alternating + Micro Low Air Loss Pressure Relief System User Manual Distributed by: Quart Healthcare Inc. www.quarthealthcare.com

Warning Connect the Master Control unit to a proper power source Do not use the system in the presence of any flammable gases (such as Anesthetic Agents) Keep the pump and mattress away from sources of liquid and open flames Keep mattress away from sharp objects The device is not AP/APG protected Keep mattress system away from heating devices Caution Consult clinical instructor before use of mattress Support surfaces should always be used in conjunction with a care plan that includes the turning/repositioning of the patient over a 24 hour period The control unit should only be repaired by an authorized distributor Do not drop the control unit or store it in direct sunlight or extreme cold conditions Operation Temp: 5 C ~ 40 C R.H. : 15% ~ 93 % During operation, cell phone with a maximum output power of 2W shall be kept at least of 3.3 m The plug is used as the disconnection device from the AC mains. The plug shall be located for easily accessible No modification of this equipment is allowed. Contraindications The system should not be applied to patients suffering from polytrauma with fractures of spine, pelvis, extremities and skull. Patients with neurological impairments and missing body perception needs their physician s prescription. Alternating pressure should not be applied to pain or pain-sensitive patients. In these cases we recommend the application of static mode or other suitable foam overlays or other materials which can be found Quart Healthcare product range. People who suffer from allergies against any of the substances used for mattress or cells body should not be positioned on the mattress.

Intended Use The Diamond 8 Plus system is a unique and innovative specialized mattress replacement unit. It features a patented 8-shape twin cell design; whereby, the bottom half of the cell is always inflated and the top half is free to alternate. The system utilizes micro low air loss technology with a low rate of flow. The advanced 3:1 alternating function also provides active prevention for pressure relief, especially for those in acute care and long term care settings (the cells inflate and deflate in a 3:1 cycle, meaning 2/3rds of the body is always supported at any one time). The soft-firm adjustment allows the patient to adjust the firmness or softness of the surface for optimal comfort. The surface also has 2 inches of enclosed convoluted foam to provide extra protection and comfort for the patient in case of power failure and the mattress deflates. Control Unit Features (pump) 5 digital pressure setting for individual preference. The pump is set to default to Alternation mode for daily operation. Press to select Static mode if required. In addition the caregiver can select the Static Function stopping the alternating function and providing only micro-low air loss therapy The auto firm function provides uniform firmness for nursing procedures Power failures produce an audio alarm for added safety. The alarm can be disabled by pushing the ALARM RESET Button on the front panel Double insulation provides near silent operation The foot board mounting rack provides convenient placement for the control unit on the bed Individual air cushion design for maximum pressure distribution Centre air cells are vented to provide micro low air loss therapy

Master Control Unit Model No. M12-2 Part No. FC-QHI0002 Size (cm) 34.5(L)x12.5 (W)x22.5(H) Weight (Kg) 3.8 Cycle Time (min) 20 min 20 min Min/Max Pressure 25 ~ 60 mmhg +/- 5 mmhg Max Flow-rate 7 L/min Rated Voltage AC 100-240V Rated Frequency 50/60 Hz Fuse Rating T1AH/ 250V Current 0.3-0.2A Classification(UL60601-1) Class II, Type BF Not AP or AGP Type Meet IP21 standard Classification to Health Canada Class 2 Mode of Operation Continuous *IP classification: IP21 First number, 2 describes the level of protection from solid objects. (up to 12 mm, e.g. person s fingers. Second number, 1 describes the level of protection from liquids. (Protection against vertically falling drops of water e.g. condensation.) Mattress Features Model No Size (cm) Weight (Kg) Cells Material Cover Type Cover Material Base Material Cells Number FM-QHI0002 89(W)x203(L)x24(H) 20 Kg Nylon w/ PU backing Zipper cover with removable foam base Nylon woven fabric w/ PU coating finish Woven Polyester fabric w/ PVC backing 18 cells

Symbols Used Class II Equipment Refer to Accompanying Documents Type BF Applied Part Waste Disposal Warning 1. Instructions for Proper Use i. Remove the existing mattress from the bed frame ii. Replace the standard mattress with mattress replacement system (orient mattress so that the air tube is at the foot of the bed) iii. Secure straps beneath the mattress to the bed frame iv. Hang the control unit on the foot board of the bed frame v. Attach the air tube connectors to the socket on the left panel of the control unit vi. Verify that air hoses are not kinked under the mattress vii. Attach cover to mattress viii. Plug in the control unit and turn on the master power switch on the right side panel (the STANDBY LED will illuminate) ix. Push the STANDBY/OPERATE button on the front panel (OPERATE LED will now be illuminated and the control unit will be in operation)

x. Pressing MAX button will activate quick inflation to bring the mattress to a flat surface for performing nursing tasks with maximum pressure. The pump is set to default back to ALTER after 30 minutes of inflation. After the mattress is fully inflated, the caregiver can transfer the patient to the mattress xi. Push MAX again to release the fast inflation mode Battery status: Orange light will be illuminated if low battery. Green light will be flashing when battery is in recharge. Low Pressure: Possible air leaks or loose tubing connection result in low pressure. Lock Function: Press the LOCK button for 3 seconds to unlock the face plate. Static Function: Push the STATIC button and adjust the comfort control by pressing the SOFT/FIRM button to achieve maximum patient comfort. On this mode the system provides only low air loss therapy. Perform a hand check by placing hand under the patient s buttocks between the cells and foam. The patient should have at least 4 cm of clearance between the buttocks and the bottom of the mattress. Dynamic Function: Push the alternate button to enable the 3:1 alternating function. CPR Deflation: For quick mattress deflation disconnect the hose connector from the controller and release the CPR quick deflation valve.

2. Cleaning Mattress Overlay The mattress should be cleaned on the bed weekly using a damp soft cloth and mild detergent. If top sheet (Top cover) or base (Bottom cover) becomes grossly soiled, put on clean gloves, plastic gown and eye protection before removing top sheet or base and disposing according to standard hospital procedures for contaminated waste. Replace with clean covers. Covers can be washed and thermally disinfected in a washing machine following below procedure: (Never use phenol based cleaning solutions) Industrial Break washes Cold 10 minutes Main washes 60 o C 6 minutes Main washes 70 o C 10 minutes Extraction 2 minutes 3 Cold Rinses Extraction 5 minutes Domestic Pre-wash Cold Main Wash 70 o C 10 minutes Extraction 2 minutes Cold Rinses Extraction 5 minutes TUMBLE DRYING OR TUNNEL DRYING IS NOT RECOMMENDED Mattress cells can be wiped with a solution of sodium hypochlorite 1000ppm or any other non-phenolic germicidal solution.

Master Control Unit SWITCH OFF THE ELECTRICAL SUPPLY TO THE PUMP AND DISCONNECT THE POWER CORD FROM THE MAIN SUPPLY BEFORE CLEANING AND INSPECTION The casing of the pump is manufactured from ABS plastic. If soiled it can be wiped down with a sodium hypochlorite solution to dilution of 1000ppm or any EPA approved hospital grade disinfectant. (Do not use phenol based cleaning solution) The air filter should also be cleaned and checked as often as possible at a minimum of every six months. Air Filter can be removed by pinching center of the filter and pulling outward from the back of the Therapy control unit. Cleaning procedure for air filter. 1. Remove Air filter and Replace a new Filter. 2. Use a soft bristle brush to remove dust and difficult dried-on soil. (Do not use phenol based cleaning solutions) (Switch off the electrical supply to the pump and disconnect the power cord from the main supply before cleaning and inspection)

3. Storage and Care Control Unit: Check the power cord and plug for abrasions and excessive wear Plug in the unit and verify air flow from the hose connection ports Place in plastic bag for storage Mattress Replacement System: Check the air manifold for kinks or breaks. Replace if necessary Twist open the CPR plug at the head of the mattress and disconnect the air feed tubes. All of the air will be expelled. Starting at the head of the mattress roll towards the foot of the bed. Use the base mounted straps to secure. Place the system in a plastic bag for storage. It is recommended that the following guidelines are used whenever the system is being stored or transported to another location: Temperature limitations -2560 o C C ~ 70 o C Relative humidity 30% ~ 93% 4. Waste Disposal This Product has been supplied from an environmentally aware manufacturer that complies with the WEEE. This product may contain substances that could be harmful to the environment if disposed of in places (landfills) that are not appropriate according the legislation. Please be environmentally responsible and recycle this product through your recycling facility at its end of life.

5. Maintenance and Troubleshooting No daily maintenance is required. This equipment should only be serviced by authorized technical personnel. Use only original spare parts and consumables. In case of minor problems refer to the following: Symptom Inspection Procedure Possible Solution The air is flowing out from the control Do the air tubes allow smooth airflow? Is an air tube kinked? Adjust the air tubes to enable smooth air flow. unit but the mattress is not inflating Is there any air leakage from the Replace with new air cells air cells? Replace with new air tubes Is there any air leakage from air Re-connect the air tubes. tube between mattress and control unit? Has the air tube connector been connected properly? The Control Unit is not working Check the fuse Replace with a new fuse. Fuses may only be exchanged by qualified and authorized personnel. Some air cells have abnormal low air pressure while the air pressure Is the connection between air cells and the manifold kinked? Adjust the connection between cells and manifold for other air cells is normal Is there any air leakage from the air cells? Replace with a new air cell. 6. Warranty Quart Healthcare Products guarantees that this equipment is free from defects in materials and workmanship. Our obligation under this warranty is limited to the repair of equipment returned to the place of purchase within 24 months of delivery date We agree to service/adjust any equipment returned, and to replace or repair any part that is proven to be a warranty defect, at no charge This warranty excludes equipment damage through shipping, tampering, improper maintenance, carelessness, accident, negligence or misuse, or products that have been altered, repaired or dismantled other than with the manufacture s written authorization and by its approved procedures and by properly qualified technicians In no event shall Quart Healthcare Products be liable for any direct, indirect or consequential damages or losses resulting from the use of equipment