Doors in watertight bulkheads of cargo ships and passenger ships

Similar documents
10 December 2010 GUIDANCE FOR WATERTIGHT DOORS ON PASSENGER SHIPS WHICH MAY BE OPENED DURING NAVIGATION

RESOLUTION MSC.235(82) (adopted on 1 December 2006) ADOPTION OF THE GUIDELINES FOR THE DESIGN AND CONSTRUCTION OF OFFSHORE SUPPLY VESSELS, 2006

INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the. IGF Code

Testing Procedures of Watertight Compartments

CHAPTER II-1 B. Construction subdivision and stability, machinery and electrical installations

RULES PUBLICATION NO. 94/P SUBDIVISION AND DAMAGE STABILITY OF NEW OIL TANKERS, CHEMICAL TANKERS AND GAS CARRIERS January

Testing Procedures of Watertight Compartments

RULES FOR THE CONSTRUCTION AND CLASSIFICATION OF SHIPS IDENTIFIED BY THEIR MISSIONS CHAPTERS SCOPE

Part 3 Hull Chapter 2 General arrangement design

Testing Procedures of Watertight Compartments

Installation of Ballast Water Management Systems

ST. VINCENT AND THE GRENADINES

PASSENGER SHIPS Guidelines for preparation of Hull Structural Surveys

ANNEX 4 ALTERNATIVE TEXT FOR OPERATIONAL GUIDELINES FOR VERIFICATION OF DAMAGE STABILITY REQUIREMENTS FOR TANKERS

Rules for Classification and Construction Additional Rules and Guidelines

GUIDELINES ON OPERATIONAL INFORMATION FOR MASTERS IN CASE OF FLOODING FOR PASSENGER SHIPS CONSTRUCTED BEFORE 1 JANUARY 2014 *

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

Guideline for Scope of Damage Stability Verification on new oil tankers, chemical tankers and gas carriers

TECHNICAL CIRCULAR. Circular No: S-P 31/13 Revision: 0 Page: 1 of 5 Date:

All IMO Members Contracting Governments to the International Convention for the Safety of Life at Sea, 1974

BMA INFORMATION BULLETIN No. 96

Periodical surveys of cargo installations on ships carrying liquefied gases in bulk

ANNEX 2. RESOLUTION MSC.256(84) (adopted on 16 May 2008)

IACS History File + TB

RESOLUTION MSC.365(93) (adopted on 22 May 2014) AMENDMENTS TO THE INTERNATIONAL CONVENTION FOR THE SAFETY OF LIFE AT SEA, 1974, AS AMENDED

RULES PUBLICATION NO. 86/P EXPLANATORY NOTES TO SOLAS CONVENTION AND DIRECTIVE 2003/25/EC STABILITY AND SUBDIVISION REQUIREMENTS

RULES PUBLICATION NO. 76/P STABILITY, SUBDIVISION AND FREEBOARD OF PASSENGER SHIPS ENGAGED ON DOMESTIC VOYAGES

PART 3 HULL INTEGRITY AND ARRANGEMENT

INTERNATIONAL MARITIME ORGANIZATION

Guideline for Scope of Damage Stability Verification on new oil tankers, chemical tankers and gas carriers *)

RESOLUTION A.567(14) adopted on 20 November 1985 REGULATION FOR INERT GAS SYSTEMS ON CHEMICAL TANKERS

Guidelines for Clean Agent Fire Suppression Systems

REGULATION on life boats operated from land, No 123/1999 CHAPTER I. General provisions Article 1

F All types of inert gas systems are to comply with the following:

ST. VINCENT AND THE GRENADINES

GUIDELINES FOR VERIFICATION OF DAMAGE STABILITY REQUIREMENTS FOR TANKERS

.3 the correct operation of the communications medium between the navigation bridge and the steering gear compartment.

ANNEX 3 DRAFT GUIDELINES FOR VERIFICATION OF DAMAGE STABILITY REQUIREMENTS FOR TANKERS GUIDELINES FOR VERIFICATION OF STABILITY ON TANKERS PART 1

MSC Guidelines for Review of Cargo and Miscellaneous Vessel Stability (Subchapter I)

RULES FOR CLASSIFICATION Ships. Part 3 Hull Chapter 15 Stability. Edition October 2015 DNV GL AS

IMO DEVELOPMENT OF EXPLANATORY NOTES FOR HARMONIZED SOLAS CHAPTER II-1

RESOLUTION MSC.256(84) (adopted on 16 May 2008) ADOPTION OF AMENDMENTS TO THE INTERNATIONAL CONVENTION FOR THE SAFETY OF LIFE AT SEA, 1974, AS

SECOND ENGINEER REG III/2 NAVAL ARCHITECTURE

MARINE CIRCULAR MC-25/2012/1

PART 3 HULL INTEGRITY AND ARRANGEMENT

Type Testing Procedure for Crankcase Explosion Relief Valves

Rules for Classification and Construction Additional Rules and Guidelines

RULES FOR THE CLASSIFICATION AND CONSTRUCTION OF SEA-GOING SHIPS

Recent Topics at IACS

Safety of Life at Sea, 1974 (SOLAS)

GUIDELINES FOR SURVEY OF OIL FLOATING STORAGE VESSELS FIXED AT ANCHORAGE

STABILITY AND WATERTIGHT INTEGRITY

Definitions 13 FREE SURFACE EFFECT

PART 1 GENERAL REQUIREMENTS

Rules for Classification and Construction Additional Rules and Guidelines

ANNEX 2 RESOLUTION MEPC.124(53) Adopted on 22 July 2005 GUIDELINES FOR BALLAST WATER EXCHANGE (G6) THE MARINE ENVIRONMENT PROTECTION COMMITTEE,

MSC Guidelines for Review of Stability for Sailing Catamaran Small Passenger Vessels (T)

New generation intact stability (Second generation intact stability criteria) (agenda item 3)

MSC Guidelines for Review of Stability for Towing Vessels (M)

TECHNICAL CIRCULAR. Circular No: S-P 32/13 Revision: 1 Page: 1 of 7 Date:

Code of safe practice for cargo stowage and securing Annex 14

SJÖFS 2002:17. Bilaga 3 Sammanställning av de resolutioner och cirkulär som det refereras till i bilaga 1 och 2.

MSC Guidelines for Sanitary & Sewage Systems

INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the COLREG

Translation: Only the Danish version is authentic. The Danish Maritime Authority s Technical Regulation no. 2 of 3 March 1998

STABILITY AND WATERTIGHT INTEGRITY, CLOSING APPLIANCES

THE APPLICATION OF SPECIAL PURPOSE SHIP (SPS) REQUIREMENTS TO OFFSHORE SUPPORT VESSELS

RULES FOR CLASSIFICATION. Ships. Part 3 Hull Chapter 15 Stability. Edition July 2016 Amended January 2017 DNV GL AS

RULES PUBLICATION NO. 119/P

Hatch cover securing and tightness

IMO EXPLANATORY NOTES FOR THE APPLICATION OF THE SAFE RETURN TO PORT REQUIREMENTS

COUNCIL OF THE EUROPEAN UNION. Brussels, 20 February /06 MAR 18

MSC/Circular.649 International Convention for the Safety of Life at Sea, 1974, as amended (Adopted on 8 June 1994)

Periodic Survey of Fuel Installations on Ships other than Liquefied Gas Carriers utilizing gas or other low flash point fuels

MSC Guidelines for Review of Passenger Vessel Stability (Subchapters K & H)

properly applied assessment in the use.1 landmarks.1 approved in-service of ECDIS is not experience The primary method of fixing required for those

Rules for Classification and Construction Ship Technology

INTERNATIONAL REGULATIONS FOR THE SAFETY OF FISHING VESSELS

Resolution A.1120(30) Adopted on 6 December 2017 (Agenda item 9)

RULES FOR THE CLASSIFICATION OF SHIPS

ANNEX 19 DRAFT ASSEMBLY RESOLUTION

PASSENGER VESSEL OPERATIONS AND DAMAGED STABILITY STANDARDS

RESOLUTION MSC.429(98) (adopted on 9 June 2017) REVISED EXPLANATORY NOTES TO THE SOLAS CHAPTER II-1 SUBDIVISION AND DAMAGE STABILITY REGULATIONS

ANNEX 15. RESOLUTION MEPC.158(55) Adopted on 13 October 2006

SOLAS requirements for nonpassenger ships 300 or above but less than 500 gross tonnage

Policy for Testing of Oil Discharge Monitoring and Control System Operational Procedure : QOP (17) Revision: 0 Page 1

The salient features of the 27m Ocean Shuttle Catamaran Hull Designs

ANNEX 5. DRAFT RESOLUTION MSC.[ ](93) (adopted on [ ])

REDUNDANT PROPULSION SHIPS RULES FOR CLASSIFICATION OF NEWBUILDINGS DET NORSKE VERITAS SPECIAL EQUIPMENT AND SYSTEMS ADDITIONAL CLASS PART 6 CHAPTER 2

RESOLUTION MSC.236(82) (adopted on 1 December 2006) ADOPTION OF AMENDMENTS TO THE GUIDELINES FOR THE TRANSPORT AND HANDLING OF LIMITED AMOUNTS OF

MERCHANT SHIPPING ACT 1985 FISHING VESSELS (LIFE-SAVING APPLIANCES) REGULATIONS 1988

MSC Guidelines for Review of Emergency Evacuation Plans (NVIC 8-93)

ANNEX 2 RESOLUTION MSC.216(82) (adopted on 8 December 2006)

MSC Guidelines for Carbon Dioxide Fire Suppression Systems

RULES FOR STATUTORY SURVEY OF SEA-GOING SHIPS SURVEY REGULATIONS 2011

South African Maritime Safety Authority Ref: SM6/5/2/1 /1

RULES FOR STATUTORY SURVEY OF SEA-GOING SHIPS. SURVEY REGULATIONS 2017 January

Rule Change Notice For: RULES FOR CLASSIFICATION OF MOBILE OFFSHORE UNITS

Translation Principles of testing and certification for insulating hose assemblies on cable cutting devices

IMO ANCHORING, MOORING AND TOWING EQUIPMENT. Submitted by the Republic of Korea

Transcription:

(June 2002) (Rev.1 Oct 2018) Doors in watertight bulkheads of cargo ships and passenger ships Application This unified interpretation pertains to doors 1 located in way of the internal watertight subdivision boundaries and the external watertight boundaries necessary to ensure compliance with the relevant subdivision and damage stability regulations. This unified interpretation does not apply to doors located in external boundaries above equilibrium or intermediate waterplanes. The design and testing requirements for watertight doors vary according to their location relative to the 1) equilibrium waterplane or intermediate waterplane at any stage of assumed flooding and or 2) bulkhead deck or freeboard deck. Members agreed that the scope of an IACS interpretation in this context shall not be limited to watertight doors covered by SOLAS. Watertight doors required by other statutory damage stability requirements, e.g. MARPOL, the IBC and IGC Codes are covered as well. This UI applies to ships subject to certification under SOLAS, MARPOL, ICLL, the IBC Code and the IGC Code in accordance with SOLAS II-1/Reg. 4.1 and Reg.4.2 as amended by resolution M.421(98). Small cargo vessels not subject to damage stability requirements are not required to comply with the full scheme 1. Footnote: 1 Doors in watertight bulkheads of small cargo ships, not subject to any statutory subdivision and damage stability requirements, may be hinged quick acting doors arranged to open out of the major space protected. They shall be constructed in accordance with the requirements of the classing society and have notices affixed to each side stating, "To be kept closed at sea". This UI shall not apply to Hs pending completion of revision of the H Code by IMO and consideration of same by the applicable IACS WPs. Note: 1. This UI is to be uniformly implemented by IACS Members and Associates from 1 January 2003. 2. Rev.1 of this Unified Interpretation is to be applied by Members on ships contracted for construction on or after 1 January 2020 (in the absence of a building contract, the keel of which is laid or which are at a similar stage of construction on or after 1 July 2020) or delivered on or after 1 January 2024. 3. The contracted for construction means the date on which the contract to build the vessel is signed between the prospective owner and the shipbuilder. For further details regarding the date of contract for construction, refer to IACS Procedural Requirement (PR) No. 29. Page 1 of 11 IACS Int. 2002/Rev.1 2018

1. Definitions For the purpose of this UI the following definitions apply: Watertight: Capable of preventing the passage of water in any direction under a design head. The design head for any part of a structure shall be determined by reference to its location relative to the bulkhead deck or freeboard deck, as applicable, or to the most unfavourable equilibrium/intermediate waterplane, in accordance with the applicable subdivision and damage stability regulations, whichever is the greater. A watertight door is thus one that will maintain the watertight integrity of the subdivision bulkhead in which it is located. Equilibrium Waterplane: The waterplane in still water when, taking account of flooding due to an assumed damage, the weight and buoyancy forces acting on a vessel are in balance. This relates to the final condition when no further flooding takes place or after cross flooding is completed. Intermediate Waterplane: The waterplane in still water, which represents the instantaneous floating position of a vessel at some intermediate stage between commencement and completion of flooding when, taking account of the assumed instantaneous state of flooding, the weight and buoyancy forces acting on a vessel are in balance. Sliding Door or Rolling Door: A door having a horizontal or vertical motion generally parallel to the plane of the door. Hinged Door: A door having a pivoting motion about one vertical or horizontal edge. 2. Structural Design Doors shall be of approved design and substantial construction in accordance with the requirements of the classing society and shall be of a strength equivalent to that of the subdivision bulkheads in which they are fitted. 3. Operation Mode, Location and Outfitting Doors shall be fitted in accordance with all requirements regarding their operation mode, location and outfitting, i.e. provision of controls, means of indication, etc., as shown in Table 1 below. This table is to be read in conjunction with the following general notes: For passenger ships the watertight doors and their controls are to be located in compliance with SOLAS II- 1/13.5.3 and II-1/13.7.1.2.2. 3.1 Frequency of Use whilst at sea Normally Kept closed at sea but may be used if authorised. To be closed again after use. Permanently The time of opening such doors in port and of closing them before the ship leaves port shall be entered in the log-book. Should such doors be accessible during the voyage, they shall be fitted with a device to prevent unauthorised opening. Normally Open May be left open provided it is always ready to be immediately closed. Used In regular use, may be left open provided it is ready to be immediately closed. Page 2 of 11 IACS Int. 2002/Rev.1 2018

3.2 Type Power operated, sliding or rolling 2 Power operated, hinged Sliding or Rolling Hinged 3.3 Control 3.3.1 Local POS POH S H All doors, except those which are to be permanently closed at sea, are to be capable of being opened and closed by hand (and by power, where applicable 3 ) locally, from both sides of the doors, with the ship listed to either side. For passenger ships, the angle of list at which operation by hand is to be possible is 15 degrees or 20 degrees if the ship is allowed to heel up to 20 degrees the maximum angle of heel during intermediate stages of flooding, whichever is the greater. For cargo ships, the angle of list at which operation by hand is to be possible is 30 degrees. 3.3.2 Remote Where indicated in Table 1, doors are to be capable of being remotely closed by power from the bridge 4 for all ships, and by hand also from a position above the bulkhead deck for passenger ships as required by SOLAS II-1/13 7.1.4. Where it is necessary to start the power unit for operation of the watertight door, means to start the power unit is also to be provided at remote control stations. The operation of such remote control is to be in accordance with SOLAS II-1/13.8.1 to 13.8.3 SOLAS II-1/15.8.1 to 15.8.3. For tankers, where there is a permanent access from a pipe tunnel to the main pump room, the watertight door shall be capable of being manually closed from outside the main pump room entrance in addition to the requirements above. 3.4 Indication 5 3.4.1 Where shown in Table 1, position indicators are to be provided at all remote operating positions 5 as well as locally, for all ships and provided locally on both sides of the internal doors 6 for cargo ships, to show whether the doors are open or closed and, if applicable, with all dogs/cleats fully and properly engaged. 3.4.2 The door position indicating system is to be of self-monitoring type and the means for testing of the indicating system are to be provided at the position where the indicators are fitted. Footnotes: 2 Rolling doors are technically identical to sliding doors. 3 Arrangements for passenger ships shall be in accordance with SOLAS II-I/15.7.1.4 13.7.1.4 and 13.7.1.5 4 Arrangements shall be in accordance with SOLAS II-1/1513.7.1.5 for passenger ships and 13-1.2 for cargo ships 5 Indication at all remote control positions (SOLAS II-I/15.6.4) 6 refer to SOLAS II-1/25-9.3 5 Refer to SOLAS II-I/Reg.13, 13-1, 15-1 and 17-1, IEC 60092-504, IMO International Code on Alarms and Indicators 2009) Page 3 of 11 IACS Int. 2002/Rev.1 2018

An indication (i.e. red light) should be placed locally showing that the door is in remote control mode ("doors closed mode"). Ref. also SOLAS Reg. 15-8.1. Special care should be taken in order to avoid potential danger when passing through the door. Signboard/instructions should be placed in way of the door advising how to act when the door is in "doors closed" mode. 3.4.3 A diagram showing the location of the door and an indication to show its position shall be provided at the central operating console located at the navigating bridge. A red light shall indicate the door is in the open position and a green light shall indicate the door is in the closed position. When the door is closed from this remote position, the red light shall flash when the door is in an intermediate position. This applies to passenger ships and cargo ships. 3.4.4 Signboard/instructions should be placed in way of the door advising how to act when the door is in "doors closed" mode. 3.5 Alarms 5 3.5.1 Failure of the normal power supply of the required alarms shall be indicated by an audible and visual alarm. 3.5.2 All door types, including power-operated sliding watertight doors which are to be capable of being remotely closed are to be provided with an audible alarm, distinct from any other alarm in the area, which will sound whenever such a door is remotely closed. For passenger ships the alarm shall sound for at least 5 s but not more than 10 s before the door begins to move and shall continue sounding until the door is completely closed. In the case of remote closure by hand operation, an alarm is required to sound only while the door is actually moving. In passenger areas and areas of high ambient noise, the audible alarms are to be supplemented by visual signals at both sides of the doors. 3.5.3 All watertight doors, including sliding doors, operated by hydraulic door actuators, either a central hydraulic unit or independent for each door is to be provided with a low fluid level alarm or low gas pressure alarm, as applicable or some other means of monitoring loss of stored energy in the hydraulic accumulators. This alarm is to be both audible and visible and shall be located on the central operating console at the navigation bridge. 3.6 Notices As shown in Table 1, doors which are normally closed at sea but not provided with means of remote closure, are to have notices fixed to both sides of the doors stating, To be kept closed at sea. Doors which are to be permanently closed at sea are to have notices fixed to both sides stating, Not to be opened at sea. Footnotes: 5 Refer to SOLAS II-I/Reg.13, 13-1, 15-1 and 17-1, IEC 60092-504, IMO International Code on Alarms and Indicators 2009) Page 4 of 11 IACS Int. 2002/Rev.1 2018

4. Fire Doors Watertight doors may also serve as fire doors but need not be fire-tested notwithstanding the fire resistance of the division in which the watertight doors are fitted. However, such doors fitted above the bulkhead deck on passenger ships shall be tested to the FTP Code in accordance with the division they are fitted. If it is not practicable to ensure self-closing, means of indication on the bridge showing whether these doors are open or closed and a notice stating To be kept closed at sea can be alternative of the self-closing. Where a watertight door is located adjacent to a fire door, both doors shall be capable of independant operation, remotely if required by SOLAS ll-1/13.8.1 to 13.8.3 and from both sides of each door. Watertight doors may also serve as fire doors but need not be fire-tested when intended for use below the bulkhead deck. Where such doors are used at locations above the bulkhead deck they shall, in addition to complying with the provisions applicable to fire doors at the same locations, also comply with means of escape provisions of SOLAS ll-2/13 (2000 Amendments, M Res. 99 (73). Where a watertight door is located adjacent to a fire door, both doors shall be capable of independant operation, remotely if required by SOLAS ll-1/15.8.1 to 15.8.3 and from both sides of the each door. 5. Testing 5.1 Doors which become immersed by an equilibrium or intermediate waterplane, are to be subjected to a hydrostatic pressure test. 5.1.1 For large doors intended for use in the watertight subdivision boundaries of cargo spaces, structural analysis may be accepted in lieu of pressure testing. Where such doors utilise gasket seals, a prototype pressure test to confirm that the compression of the gasket material is capable of accommodating any deflection, revealed by the structural analysis, is to be carried out. 5.2 Doors which are not immersed by an equilibrium or intermediate waterplane but become intermittently immersed at angles of heel in the required range of positive stability beyond the equilibrium position are to be hose tested 67. For clarification purposes it shall be noted that even though these doors are covered by the text in this UI, in accordance with the practice of LL, SOLAS and MARPOL Conventions such hose testing usually is related to weathertight doors rather than to watertight doors. 5.3 Pressure Testing 5.3.1 The head of water used for the pressure test shall correspond at least to the head measured from the lower edge of the door opening, at the location in which the door is to be fitted in the vessel, to the bulkhead deck or freeboard deck, as applicable, or to the most unfavourable damage waterplane, if that be greater. Testing may be carried out at the factory or other shore based testing facility prior to installation in the ship. Footnotes: 67 Additionally, such doors may need to be pressure tested to a head as specified by a National standard or regional agreement Page 5 of 11 IACS Int. 2002/Rev.1 2018

5.3.2 Leakage Criteria 5.3.2.1 The following acceptable leakage criteria should apply to Doors with gaskets No leakage Doors with metallic sealing Max leakage 1 liter litre/min. 5.3.2.2 Limited leakage may be accepted for pressure tests on large doors located in cargo spaces employing gasket seals or guillotine doors located in conveyor tunnels, in accordance with the following 78 3 ( P + 4.572) h Leakage rate(litre/min) = 6568 where: P = perimeter of door opening (metres) h = test head of water (metres) 5.3.2.3 However, in the case of doors where the water head taken for the determination of the scantling does not exceed 6.10 m, the leakage rate may be taken equal to 0.375 liter litre/min if this value is greater than that calculated by the above-mentioned formula. 5.3.3 For doors on passenger ships which are normally open and used at sea or which become submerged by the equilibrium or intermediate waterplane, a prototype test shall be conducted, on each side of the door, to check the satisfactory closing of the door against a force equivalent to a water height of at least 1 m above the sill on the centre line of the door 8 9. 5.4 Hose Testing 5.4.1 All watertight doors shall be subject to a hose test in accordance with UR S14.2.3 after installation in a ship. Hose testing is to be carried out from each side of a door unless, for a specific application, exposure to floodwater is anticipated only from one side. Where a hose test is not practicable because of possible damage to machinery, electrical equipment insulation or outfitting items, it may be replaced by means such as an ultrasonic leak test or an equivalent test. Footnote: 7 8 Published in the ATM F 1196, Standard Specification for Sliding Watertight Door Assemblies and referenced in the Title 46 US Code of Federal Regulations 170.270 Door design, operation installation and testing 8 9 Arrangements for passenger ships shall be in accordance with SOLAS Reg. II-1/15.6.2 13.5.2 Page 6 of 11 IACS Int. 2002/Rev.1 2018

Table 1: Doors in Internal Watertight Bulkheads and External Watertight Boundaries in Cargo Ships and Passenger Ships A. Door in Internal Watertight Bulkheads Position relative to bulkhead or freeboard deck 1. I. Passenger Ships Regulation 2. Frequency of Use while at sea 3. Type 4. Remote Closure 5. Remote Indication 6. Audible or Visual Alarm 7. Notice 8. Comments (1)Below SOLAS II-1/13.4, 13.5.1, 13.5.2,13.6, 13.7.1,13.8.1, 13.8.2, 22.1, 22.3 and 22.4 POS (local) No Certain doors may be left open, see SOLAS II-1/22.3 and IMO M.1/Circ.4 (2)At or above SOLAS II-1/13.9.1, 13.9.2, 14.2, 22.2 and 22.5 SOLAS II-1/17.1 and 22.3 SOLAS II-1/17-1.1, 17-1.2, 17-1.3, 23.6 and 23.8 S, H No No No See Notes 3 + 4 + 6 POS, POH (local) No See Note 7 S, H No No See Note 1 S, H No (remote) Doors giving access to below Ro-Ro Deck SOLAS II-1/17-1.1, 17-1.2, 17-1.3, 22.7 and 23.3 to 23.5 S, H No (remote) See Notes 1 + 3 + 4 Page 7 of 11 IACS Int. 2002/Rev.1 2018

II. Cargo Ships (1)Below (2)At or above SOLAS II-1/13-1.2 and 22.3 MARPOL I/28.3 ICLL66+A.320 1988 Protocol to ICLL66 IBC, and IGC SOLAS II-1/13-1.3, 22.3 and 24.4 SOLAS II-1/13-1.4, 24.3, and 24.4 SOLAS II-1/ 13-1.4, 13-1.5, 22.2, 24.3 and 24.4 SOLAS II-1/13-1.2 and 22.3 MARPOL I/28.3 ICLL66+A.320 1988 Protocol to ICLL66 IBC, and IGC SOLAS II-1/13-1.3, 22.3 and 24.4 SOLAS II-1/13-1.4, 13-1.5, 24.3 and 24.4 Used POS (local) S, H No No See Note 1 S, H No No No See Notes 3 + 4 Used POS (local) No No See Notes 2 + 5 S, H No No See Note 1 S, H No No No See Notes 3 + 4 Page 8 of 11 IACS Int. 2002/Rev.1 2018

Notes: 1. If hinged, this door shall be of quick acting or single action type. 2. Under ICLL66, doors separating a main machinery space from a steering gear compartment may be hinged quick acting type provided the lower sill of such doors is above the Summer Load Line and the doors remain closed at sea whilst not in use. 3. The time of opening such doors in port and closing them before the ship leaves port shall be entered in the logbook, in case of doors in watertight bulkheads subdividing cargo spaces. 4. Doors shall be fitted with a device which prevents unauthorized opening. 5. Under MARPOL, hinged watertight doors may be acceptable in watertight bulkhead in the superstructure. 6. Passenger ships which have to comply with SOLAS II-1/14.2 require an indicator on the navigation bridge to show automatically when each door is closed and all door fastenings are secured. 7. Refer to the Explanatory Note to Regulation 17.1 of Res.M.429(98) regarding sliding watertight doors with a reduced pressure head and sliding semi-watertight doors. Page 9 of 11 IACS Int. 2002/Rev.1 2018

B. Door in External Watertight Boundaries below equilibrium or intermediate waterplane Position 1. relative to bulkhead deck Regulation or freeboard deck I. Passenger Ships SOLAS II-1/15.9, (1)Below 22.6 and 22.12 SOLAS II-1/17.1 and 22.3 M.Circ.541 SOLAS II-1/17-1.1, (2)At or above 17-1.2, 17-1.3, 23.6 and 23.8 SOLAS II-1/17-1.1, 17-1.2, 17-1.3, 23.3 and 23.5 II. Cargo Ships (1)Below (2)At or above SOLAS II-1/15.9, 15-1.2, 15-1.3, 15-1.4, 22.6, 22.12 and 24.1 SOLAS II-1/15-1.2 SOLAS II-1/15-1.2 and 15-1.4 2. Frequency of Use while at sea 3. Type 4. Remote Closure 5. Remote Indication 6. Audible or Visual Alarm 7. Notice 8. Comments S, H No No No See Notes 2 + 3 S, H No No See Note 1 S, H No S, H No (Remote) (Remote) Doors giving access to below Ro-Ro Deck See Notes 2 + 3 S, H No No See Notes 2 + 3 S, H No No See Note 1 S, H No No See Notes 2 +3 Notes: 1. If hinged, this door shall be of quick acting or single action type. 2. The time of opening such doors in port and closing them before the ship leaves port shall be entered in the logbook. 3. Doors shall be fitted with a device which prevents unauthorized opening. Page 10 of 11 IACS Int. 2002/Rev.1 2018

Table 1. Internal Doors in Watertight Bulkheads in Cargo Ships and Passenger Ships Position relative to equilibrium or intermediate waterplane I. Passenger Ships A. At or below B. Above II. Cargo Ships A. At or below B. Above 1. Frequency of Use whilst at sea 2. Type 3. Remote Control 6 4. Indicatio n locally and 6 5. Audible Alarm 6 POS No 6. Notice 7. Comments Certain doors may be left open, see SOLAS II-1/15.9.3 S, H No No No see Notes 1 + 4 open POS, 8. Regulation SOLAS II-1/ 15.9.1,2 & 3 SOLAS II-1/ 15.10.1 & 2 No SOLAS II-1/ S, H No No S, H No No see Note 2 Doors giving access to Ro-Ro Deck 15.9.3 SOLAS II- 1/20.1 M/Circ.541 SOLAS II-1/20-2 Used POS No SOLAS II-1/ 25-9.2 S, H No No see Notes 2 + 3 + 5 SOLAS II-1/ 25-9.3 S, H No No No see Notes 1 + 4 SOLAS II-1/ 25-9.4 SOLAS II-1/ 25-10 Used POS No SOLAS II-1/ 25-9.2 closed S, H No No See Notes 2 + 5 SOLAS II-1/ 25-9.3 SOLAS II-1/ 25-10 Notes: 1. Doors in watertight bulkheads subdividing cargo spaces. 2. If hinged, this door shall be of quick acting or single action type 3. "ICLL66+A.320" or "1988 Protocol to ICLL66", SOLAS, MARPOL, IGC and IBC- Codes require remotely operated watertight doors to be sliding doors. 4. The time of opening such doors in port and closing them before the ship leaves port shall be entered in the logbook. 5. The use of such doors shall be authorised by the officer of the watch. 6. Cables for control and power systems to power operated watertight doors and their status indication should comply with the requirements of UR E15. Page 11 of 11 IACS Int. 2002/Rev.1 2018