RESILIENT INFRASTRUCTURE June 1 4, 2016

Similar documents
INTERFERENCE EFFECTS OF TWO BUILDINGS ON PEAK WIND PRESSURES

An Overview of Wind Engineering Where Climate Meets Design

EXPERIMENTAL STUDY OF WIND PRESSURES ON IRREGULAR- PLAN SHAPE BUILDINGS

Numerical Analysis of Wind loads on Tapered Shape Tall Buildings

Effects of wind incidence angle on wind pressure distribution on square plan tall buildings

Quantification of the Effects of Turbulence in Wind on the Flutter Stability of Suspension Bridges

Wind Pressure Distribution on Rectangular Plan Buildings with Multiple Domes

Wind Flow Model of Area Surrounding the Case Western Reserve University Wind Turbine

Journal of Engineering Science and Technology Review 9 (5) (2016) Research Article. CFD Simulations of Flow Around Octagonal Shaped Structures

Critical Gust Pressures on Tall Building Frames-Review of Codal Provisions

COMPARISONS OF COMPUTATIONAL FLUID DYNAMICS AND

Along and Across Wind Loads Acting on Tall Buildings

Wind Loading Code for Building Design in Thailand

Experimental Investigation Of Flow Past A Rough Surfaced Cylinder

130 William Street New York, NY, USA

Wind Flow Validation Summary

THE BRIDGE COLLAPSED IN NOVEMBER 1940 AFTER 4 MONTHS OF ITS OPENING TO TRAFFIC!

COMPUTATIONAL FLOW MODEL OF WESTFALL'S LEADING TAB FLOW CONDITIONER AGM-09-R-08 Rev. B. By Kimbal A. Hall, PE

Aspects of Using CFD for Wind Comfort Modeling Around Tall Buildings

RESILIENT INFRASTRUCTURE June 1 4, 2016

TOWARD MORE ACCURATE PREDICTION OF DAMAGE DUE TO STRONG WINDS

External Pressure Coefficients on Saw-tooth and Mono-sloped Roofs

EFFECTS OF SIDEWALL OPENINGS ON THE WIND LOADS ON PIPE-FRAMED GREENHOUSES

UNIVERSITY OF HONG KONG LIBRARY. Hong Kong Collection

Australian Journal of Basic and Applied Sciences. Pressure Distribution of Fluid Flow through Triangular and Square Cylinders

Pressure coefficient on flat roofs of rectangular buildings

SEMI-SPAN TESTING IN WIND TUNNELS

Influence of rounding corners on unsteady flow and heat transfer around a square cylinder

A Study on the Effects of Wind on the Drift Loss of a Cooling Tower

Surrounding buildings and wind pressure distribution on a high rise building

Dear Mr. Nicolini: Qualitative Pedestrian Level Wind Assessment Montreal Road, Ottawa GWE File No.: DTPLW

THREE DIMENSIONAL STRUCTURES OF FLOW BEHIND A

AERODYNAMIC FEATURES AS AUXILIARY ARCHITECTURE

PRESSURE FLUCTUATIONS ACTING ON A TAPERED TALL BUILDING

Aerodynamic Measures for the Vortex-induced Vibration of π-shape Composite Girder in Cable-stayed Bridge

AIRFLOW GENERATION IN A TUNNEL USING A SACCARDO VENTILATION SYSTEM AGAINST THE BUOYANCY EFFECT PRODUCED BY A FIRE

APPLICATION OF COMPUTATIONAL FLUID DYNAMICS (CFD) IN WIND ANALYSIS OF TALL BUILDINGS. Damith Mohotti, Priyan Mendis, Tuan Ngo

Investigations on the Aerodynamic Forces of 2-D Square Lattice Tower Section Using CFD

6. EXPERIMENTAL METHOD. A primary result of the current research effort is the design of an experimental

A Wind-Tunnel Study of a Cubic Rooftop AC Unit on a Low Building

Numerical and Experimental Investigation of the Possibility of Forming the Wake Flow of Large Ships by Using the Vortex Generators

Wind tunnel test and numerical simulation of wind pressure on a high-rise building

WIND LOADS / MOORING & FISH TAILING. Arjen Koop, Senior Project Manager Offshore Rogier Eggers, Project Manager Ships

Available online at ScienceDirect. Procedia Engineering 126 (2015 )

Dear Ms. Maw: Qualitative Pedestrian Level Wind Assessment St-Charles Market, 135 Barrette Street, Ottawa GWE File No.

Ermenek Dam and HEPP: Spillway Test & 3D Numeric-Hydraulic Analysis of Jet Collision

Wind-Induced Oscillations Parametric Wind Tunnel Test

WIND-INDUCED LOADS OVER DOUBLE CANTILEVER BRIDGES UNDER CONSTRUCTION

NUMERICAL INVESTIGATION OF THE FLOW BEHAVIOUR IN A MODERN TRAFFIC TUNNEL IN CASE OF FIRE INCIDENT

EMPIRICAL EVALUATION OF THREE WIND ANALYSIS TOOLS FOR CONCEPT DESIGN OF AN URBAN WIND SHELTER

THEORETICAL EVALUATION OF FLOW THROUGH CENTRIFUGAL COMPRESSOR STAGE

CFD AND EXPERIMENTAL STUDY OF AERODYNAMIC DEGRADATION OF ICED AIRFOILS

Forest Winds in Complex Terrain

EXAMINING THE EFFECT OF HEAVY VEHICLES DURING CONGESTION USING PASSENGER CAR EQUIVALENTS

NUMERICAL SIMULATION OF STATIC INTERFERENCE EFFECTS FOR SINGLE BUILDINGS GROUP

Study by numerical simulations on the breathing effect in a semi-underground highway with beams and a roof above it

Evaluating the Design Safety of Highway Structural Supports

A comparison of NACA 0012 and NACA 0021 self-noise at low Reynolds number

Single Phase Pressure Drop and Flow Distribution in Brazed Plate Heat Exchangers

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 2, No 3, 2012

Development of Technology to Estimate the Flow Field around Ship Hull Considering Wave Making and Propeller Rotating Effects

Measurement and simulation of the flow field around a triangular lattice meteorological mast

EXPERIMENTAL INVESTIGATION OF WAKE SURVEY OVER A CYLINDER WITH DIFFERENT SURFACE PROFILES

Basis of Structural Design

Lehigh-FIU Hybrid Wind Simulation Developments

Inlet Influence on the Pressure and Temperature Distortion Entering the Compressor of an Air Vehicle

Computationally Efficient Determination of Long Term Extreme Out-of-Plane Loads for Offshore Turbines

EXPERIMENTAL ANALYSIS OF THE CONFLUENT BOUNDARY LAYER BETWEEN A FLAP AND A MAIN ELEMENT WITH SAW-TOOTHED TRAILING EDGE

THE 21 st CHESAPEAKE SAILING YACHT SYMPOSIUM ANNAPOLIS, MARYLAND, MARCH 2013

AIRFLOW AROUND CONIC TENSILE MEMBRANE STRUCTURES

Effect of Diameter on the Aerodynamics of Sepaktakraw Balls, A Computational Study

Computational Investigation of Airfoils with Miniature Trailing Edge Control Surfaces

THE COLLEGE OF AERONAUTICS CRANFIELD

Journal of Engineering Science and Technology Review 6 (3) (2013) Research Article

average length of the bluff body surface reattachment will decrease with blockage ratio increasing. Cherry's test results showed that 5% of the blocka

Development of Biomimicry Wind Louver Surface Design

2013 Wall of Wind (WoW) Contest Informational Workshop

Post-mortem study on structural failure of a wind farm impacted by super typhoon Usagi

International Journal of Technical Research and Applications e-issn: , Volume 4, Issue 3 (May-June, 2016), PP.

Figure 1. Outer dimensions of the model trucks.

Wind Directional Effect on a Single Storey House Using Educational Wind Tunnel

Research Article Effects of Side Ratio on Wind-Induced Pressure Distribution on Rectangular Buildings

AN INVESTIGATION OF LONGITUDINAL VENTILATION FOR SHORT ROAD TUNNELS WITH HIGH FIRE HRR

FLOW CONSIDERATIONS IN INDUSTRIAL SILENCER DESIGN

A Computational Assessment of Gas Jets in a Bubbly Co-Flow 1

Techniques to achieve wind comfort & wind loads on buildings and appurtenances

CFD Study of Solid Wind Tunnel Wall Effects on Wing Characteristics

Wind tunnel tests of a non-typical stadium roof

Aerodynamic study of a cyclist s moving legs using an innovative approach

A Study on Roll Damping of Bilge Keels for New Non-Ballast Ship with Rounder Cross Section

The Wake Wash Prediction on an Asymmetric Catamaran Hull Form

A noise generation and propagation model for large wind farms

High Swept-back Delta Wing Flow

Influence of an upstream building on the wind-induced mean suction on the flat roof of a low-rise building

SITE AND BUILDING INFORMATION. March 28, 2018

Development of TEU Type Mega Container Carrier

A COMPARATIVE STUDY OF MIX FLOW PUMP IMPELLER CFD ANALYSIS AND EXPERIMENTAL DATA OF SUBMERSIBLE PUMP

THE TACOMA NARROWS BRIDGE FAILURE Revision A

Welcome to Aerospace Engineering

AIRFLOW AND TEMPERATURE FIELD CALCULATIONS FOR WINTER SPORTS FACILITIES

Transcription:

RESILIENT INFRASTRUCTURE June 1 4, 2016 CASE STUDIES ON THE IMPACT OF SURROUNDING BUILDINGS ON WIND-INDUCED RESPONSE John Kilpatrick Rowan Williams Davies and Irwin, Guelph, Ontario, Canada ABSTRACT In multi-tower and/or multi-phase developments, the impact of prominent nearby surroundings can play a large role in the aerodynamic conditions of proposed developments. This paper focuses on two case studies: i) two 160 m tall residential towers atop a prominent transportation terminal and ii) a tall (220 m) residential tower in complex terrain with significant future development. Comparisons will be made of the structural wind loads on the towers under various sheltering conditions. Both cases quantifies the amplification of wind loads due to vortex shedding off an existing upwind building 4 to 6 building widths upstream, as well as the role that a future development might play in modifying these amplifications. Comparisons will also be made to various empirical methods. This study also examines the aerodynamic impact of the two respective proposed towers in case i) as a result of their relative proximity within 2 building widths. Keywords: Wind loads, aerodynamic interference factors, dynamics, code 1. INTRODUCTION In multi-tower and/or multi-phase developments, the impact of prominent nearby surroundings can play a large role in the aerodynamic conditions of proposed developments. However, for the practicing designer, there is little design guidance which falls readily to hand which advises on how one might assess the adverse impact of surroundings. The 2010 NBCC [1] recommends the Experimental Procedure for buildings that may be subjected to buffeting or channeling effects caused by upwind obstructions, but is unclear regarding what situations might cause adverse buffeting or funneling response. The 2010 ASCE 7 Standard provides similar guidance, recommending the Wind Tunnel procedure if the building has response characteristics making it subject to across-wind loading, vortex shedding, instability due to galloping or flutter; or it has a site location for which channeling effects or buffeting in the wake of upwind obstructions warrant special consideration. Very little additional guidance is given to the practitioner. While this is perhaps beneficial to the Wind Engineering practitioner, there are practical design decisions which are impacted by significant departures from the initial concept design of a development. Other codes of practice give similar recommendations. While this guidance is well placed, it would be useful to have some provisions embedded in code to permit evaluation of potential wind impacts due to surrounding buildings at early design stages, for the purposes of concept design and preliminary costing exercises. A literature review suggests that there are a number of good guidelines in existence, and the author will use selected advice to illustrate its value in identifying potential wake interference problems. 2. SELECT RESEARCH ON INTERFERENCE The adverse aerodynamic interference effects on the responses of tall buildings caused by proximity to adjacent structures has been systematically studied since the 1970 s. Many point to the collapse of 3 of 8 of the cooling towers at the Ferrybridge Power Station in West Yorkshire, England, in 1965 as one of the seminal moments in the NDM-546-1

formation of the field of Wind Engineering aerodynamic interference is cited as one of the causes of the failure of these cooling towers, though there were several other factors which contributed. The degree of interference effect has been shown by numerous researchers to be influenced by the geometric massing of the upstream building, with buildings of similar height or higher upstream having larger adverse impacts on mean and fluctuating along-wind and across-wind loading. Khanduri et al (1998) reviewed the state-of-the-art of wind-induced interference effects, and also undertook parametric studies on prismatic building models to evaluate and identify or map locations wake interference effects as a function of the spacing between buildings, where the spacing was a function of the breadth of the upwind building. Khanduri introduced Interference Factors (IF s) to describe the change in mean and fluctuating along- and across-wind loading due to aerodynamic interference between simple square cylinders. An important part of Khanduri (1997) was identifying influence areas for dynamic interference effects (Figure 1). Clearly, when the upstream building was nearly adjacent to the study building, or quite distant (say 8 building diameters upstream), adverse effects were neglibible. The most significant impacts occurred with buildings spaced between 3 and 6 diameters apart. Significant work has been carried out on this topic since the late 1990 s, and recent efforts by Mara et al (2012, 2014) take these concepts further. Mara identifies aerodynamic interference effects (AIF s) which are related to the change in mean and fluctuating external wind forces, and Total Interference Effects (RIF s) which identifies the total interference effect on peak building response, including inertial forces. Figure 2 illustrates the RIF for the peak across-wind response of a tall building in open country wind exposure, at a non-dimensional wind velocity of V/fD=10 and 2% critical structural damping. For this particular plot, it is clear that the maximum amplification of the total across-wind response of a tower at a critical non-dimensional wind speed of V/fD=10 occurs when the spacing to the interfering building is 4-6 times the breadth of the upwind building, and the buildings are not aligned in the lateral direction. Perhaps the only criticism of these studies which prevents the work from being adopted by code is that these (and other) studies take a simplistic approach to the issue of interference. Prismatic (square) buildings are used in boundary layer flows which are based on uniform upwind terrain, while in reality the wind profiles and surroundings of a tall building in many developed cities is far more complicated. The value of the empirical wind tunnel studies noted above is perhaps in the indicative rather than absolute values of the wake interference phenomenon. Regardless, this is still of value and worthy of merit for inclusion in a codebased assessment method. To date, the author is not convinced that computational fluid dynamics (CFD) simulations are appropriate for global assessment of interference effects, though it has been adopted to evaluate changes in local surface pressures. 3. CASE STUDIES OF WIND-INDUCED INTERFERENCE IN ACTUAL BUILT ENVIRONMENT Based on the factors identified in the preceding sections, two case studies have been selected by the author to evaluate the relevance of the aforementioned interference factors in real urban building environments. 3.1 Case Study #1 Case study #1, presented in Figure 3a and 3b, is a multi-tower development in the southern United States, comprised of office, hotel and residential towers situated above a train station. The two main towers of the development are of similar height (160m), with spacing between the towers of approximately 2.5 building diameters. RWDI was involved in wind tunnel testing of these towers for existing (Figure 3a) and future (Figure 3b) surrounding scenarios. Structural sign convention for the tower is provided in Figure 4. Figure 5 indicates a severe peak across-wind response in the Mx base moment for winds approaching from 200. For the existing surroundings, the wind-induced response of the southern-most tower, Tower 3, is influenced by wake buffeting from a 6-sided tower upwind to the SSW. The upwind tower is of similar breadth, and moderately taller. The spacing between the upwind building and Tower 3 is on the order of 4.5 times the breadth of the upwind tower. NDM-546-2

For the future scenario, a super-tall building is located immediately to the south of Tower 3, a distance of 3-4 building diameters upstream. The super-tall building to the South was anticipated to have a much more significant wake impact on Tower 3 than the 6-sided building to the SSW, but wind tunnel tests proved this belief to be deceptive (Figure 6). In fact, the presence of the super tall building to the south has a mitigating effect on the peak across-wind Mx base moments for winds approaching from 200, though another across-wind peak is now present for winds approaching from 180, where the supertall building is directly upwind. Unfortunately, the wind-induced response of the case study tower was not measured without the interfering building, since the interfering tower is an existing building, topped out in 1985. However, based on the fluctuating acrosswind response from adjacent wind directions, one could infer that the peak across-wind response from 200 wind direction may be on the order of 1.5-2 times the across-wind response in the absence of the interfering building. The non-dimensional wind speed V/fD associated with the response curve in Figure 5 is between 6 and 7, and damping was taken to be 2.5%. The fluctuating lift response IF s from Khanduri suggest that an IF of about 1.1 may have been anticipated for the Case Study #1 tower, while data from Mara et al suggest an appropriate RIF may have been 1.1 < RIF < 1.2. These values are significantly different from the amplification of response inferred from the wind tunnel data for 200 wind direction. This may be related to a complex flow pattern in the multi-tower development. However in Figure 6 it is evident that the across-wind response for winds approaching from 180 has increased on the order of 10%, which is consistent with the Khanduri and Mara research, and flow patterns within the multi-tower development are expected to be more symmetric for this wind direction. The interference factors extracted from literature are not predicting the absolute magnitude of the increase in peak response well, but they are correctly identifying that response is likely to increase. 3.2 Case Study #2 Case study #2, presented in Figure 7a and 7b, is a 220 m single-tower development in the United Kingdom with residential occupancy. RWDI was involved in wind tunnel testing of these towers for existing (Figure 7a) and future (Figure 7b) surrounding scenarios. Sign convention for the tower is provided in Figure 8. For the existing surroundings, the My base overturning moment of the tower is governed by a large across-wind response to winds from the south (Figure 9, blue curves). The addition of future surroundings to the south, the windinduced response of the study building is strongly influenced by interference from a tower upwind, directly to the south (Figure 9, red curves). The upwind tower is of similar breadth, and moderately taller. The spacing between the upwind building and Tower 3 is on the order of 6-7 times the breadth of the upwind tower. Based on the fluctuating across-wind My base moment response illustrated in Figure 9, one can infer that the peak across-wind response has increased by about 30% as a result of the interfering building. Note maximum across-wind response does not occur when the buildings are in perfect alignment, i.e. wind approaching from 190, but for winds about 10-20 either side. The non-dimensional wind speed V/fD associated with the response curve in Figure 9 is about 8, and damping was taken to be 2%. The fluctuating lift response IF s from Khanduri suggest that an IF of about 1.0-1.1 may have been anticipated for the Case Study #2 tower, and data from Mara et al suggest a similar RIF. These values are slightly lower that the amplification of response indicated in the wind tunnel data in Figure 9. This may be related to a complex shear layer in the wake of the interfering tower, which has a rectangular footprint with a plan aspect ratio of 1:2. 4. CONCLUSIONS Interference factors, while developed on generic prismatic cylinders in uniform terrain, do have value in providing an order of magnitude estimate of the adverse wind impacts related to aerodynamic interference from surrounding buildings. Limited results of two Case Studies indicate higher than anticipated interference factors. Contributing factors for the discrepancy may include the influence of additional surrounding buildings, and geometries of interfering building which vary from a square planform. NDM-546-3

Admittedly wind tunnel testing is preferred for the purpose of assessing demand on the main lateral wind load resisting system. However, in early design stages interference factors may be helpful in identifying problems before design progresses to latter stages when the costs of mitigating a wind-issue increase. REFERENCES NRC (2010), User s Guide NBC 2010 Structural Commentaries (Part 4 of Division B), Canadian Commission on Building and Fire Codes, National Research Council Canada, Ottawa. ASCE (2010), Minimum Design Loads for Buildings and Other Structures, ASCE 7-10, Reston, VA. Khanduri, A.C. (1997). Wind-induced Interference Effects on Buildings Integrating Experimental and Computerized Approaches. Ph.D. Thesis, Concordia University. Khanduri, A.C., Stathopoulos, T., Bedard, C., 1998. Wind-induced interference effects on buildings a review of the state-of-the-art. Engineering Structures, 20, 617-630. Mara, T.G.,Ho,T.C.E.,Isyumov,N.,2012.Interference and influence of nearby buildings: a discussion of the design approach. In: Proceedings of the 2012 Structures Congress, American Society of Civil Engineering, Chicago, IL, 798 808. Mara, T.G.,Terry, B.K, Ho,T.C.E.,Isyumov,N., 2014. Aerodynmamic and peak response interference factors for an upstream square building of identical height. Journal of Wind Engineering and Industrial Aerodynamics, 133, 200-210. NDM-546-4

Figure 1: Influence Areas for Dynamic Interference Effects (Khanduri 1997) Figure 2: Peak (Total) Across-wind Response Interference Factor, V/fD=10 (Mara et al 2013) NDM-546-5

Figure 3: Wind tunnel test of Case 1: a) existing; and b) future surroundings Figure 4: Case Study #1 - Sign Convention Figure 5: Wind-induced overturning moment, Case 1 existing surrounds NDM-546-6

Figure 6: Case 1 - impact of future surrounds on overturning moment Figure 7: Wind tunnel test of Case 2: a) existing; and b) future surroundings Figure 8: Sign convention NDM-546-7

Figure 9: Wind-induced overturning moment, Case 2 existing (blue) and future (red) surrounds NDM-546-8