Determination of capsaicinoid profile of some peppers sold in Nigerian markets

Similar documents
Determination of Capsaicin Content and Pungency Level of Five Different Peppers Grown in Nigeria.

Comparative analysis of mass spectral matching for confident compound identification using the Advanced Electron Ionization source for GC-MS

May 1, By John Heim,Doug Staples

DETERMINATION OF CAPSAICIN CONTENT AND PUNGENCY LEVEL OF DIFFERENT FRESH AND DRIED CHILLI PEPPERS

Longterm Detection of Anabolic Steroid Metabolites in Urine

Technical Procedure for Drug Chemistry Gas Chromatograph/Mass Spectrometry (GC-MS)

Toxicology Gas Chromatography-Mass Spectrometry (GC-MS)

Using the PreVent System in Time-Saver Mode with the AutoSystem XL Gas Chromatograph and the TurboMass Mass Spectrometer

Variation of capsaicinoids in chilli (Capsicum frutescens L.) cultivars with the maturity of fruits in middle hill conditions of western Himalayas

Integration of amino acid, acylcarnitine and steroids analysis in single FIA/LC-MS/MS platform

DETERMINATION OF TETRAHYDROTHIOPHENE IN AMBIENT AIR BY GAS CHROMATOGRAPHY WITH A PFPD DETECTOR COUPLED TO A PRECONCENTRATION TECHNOLOGY

GCMSD-Headspace Analysis SOP

Experiment GC : Analysis of BTEX by GC-FID

APPLICATION NOTE. Fast Analysis of Coal Mine Gas Using the INFICON 3000 Micro GC ABSTRACT

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

Trace-Level Analysis of Metanephrines in Plasma by HILIC LC-MS/MS

Pressurized Liquid Extraction of Capsaicinoids from Peppers

Operation of the Perkin Elmer TGA-GC/MS

Weiyi Zheng, Xiaoxia Dong, Evan Rogers, Jimmie C. Oxley, and James L. Smith*

Retention Time Locking: Concepts and Applications. Application

Chilli Oleoresin Paprika Oleoresin Paprika Extract Oil

Gas Chromatography. MS Vent Enhancement to the PreVent System to Optimize Operation with the TurboMass, TurboMass Gold, and Clarus 500 GC/MS Systems

Influence of process parameters on the extraction of capsaicinoids from various Capsicum species cultivated in Romania

Gas chromatographic determination of 1,4-dioxane at the

Extend the time window for the detection of low level anabolic androgenic steroids and their metabolites

TROUBLESHOOTING. Dwell Volume Revisited. Gradient transfer does not have to be problematic.

CHM Gas Chromatography: Our Instrument Charles Taylor (r10)

extraction of EG and DEG from the matrix. However, the addition of all diluent at once resulted in poor recoveries.

Simplified Backflush Using Agilent 6890 GC Post Run Command Application Note

This GC has two columns (I think new columns can be ordered from Restek)

Rapid and Reliable Detection of Dissolved Gases in Water

Supplementary Information

SUPPORTING INFORMATION

Supporting Information for Micro-Collection of. Gases in a Capillary Tube: Preservation of Spatial

Analysis of Melamine and Cyanuric Acid in Food Matrices by LC-MS/MS

The instrument should have a mass range from 2 to 2000 m/z or better Interface

M/s. Thermo fisher Scientific

DETERMINATION OF THE CONTENT OF CAPSAICIN AND DIHYDROCAPSAICIN IN TWELVE VARIETIES OF CHILLI PEPPERS USING LIQUID CHROMATOGRAPHY WITH UV/VIS DETECTION

Multiple Gas#5 GC configuration Jan 2016

(2 pts) Draw the line of best fit through the data and estimate the concentration of Fe in your sample solution.

LCMSMS Solutions For Steroid Analysis

High speed UHPLC-MS/MS determination of multiple steroids in human serum using the Nexera MX system for multiplex analysis

User guide for operating the Agilent 6420A QqQ mass spectrometer by direct infusion/injection

CHE 4115 Chemical Processes Laboratory 2 Experiment 1. Batch Distillation

Gas Chromatography-Mass Spectrometry Analysis Of Organics In Drinking Water: Concentrates And Advanced Waste Treatment Concentrates, Vol.

HPLC Determination of Capsaicinoids with Cross-Linked C18 Column and Buffer-Free Eluent

Analysis of Benzenesulfonic Acid and P-Toluenesufonic Acid Esters in Genotox Monitoring using UPLC/UV-MS

SRI 8610C Gas Chromatograph Multiple Gas #3 GC configuration

Extended Application Note

Total Pressure Measurement Using Residual Gas Analyzers

APPLICATION NOTE. GC Integrated Permeation Device

Determination of Selected ASTM Perfluorinated Compounds (PFCs) Using the Shimadzu LCMS No. LCMS-083. No. SSI-LCMS-083

TRACE LEVEL DETERMINATION OF PER- AND POLYFLUOROALKYL SUBSTANCES (PFASs) IN WATER USING THE AGILENT 6460 LC/MS/MS

Quantitative Analysis of Hydrocarbons by Gas Chromatography

Outgassing, photoablation and photoionization of organic materials by the electron-impact and photon-impact methods

FROG-4000 TM Chemical Analysis System

Commercial Practice Test Method Internal Vapor Analysis of Hermetic Devices

System Overview. TCD Detector temperature setpoint Regulator

Automated Determination of Dissolved Gases in Water Anne Jurek. Abstract: Discussion:

Differences of capsaicinoids content in pericarp and paste of soft-flesh Capsicum spp. fruit

Low-Pressure Retention Time Locking with the 7890A GC. Application. Authors. Abstract. Introduction HPI

Flare Gas Composition Analysis and QA/QC Lessons Learned and Lessons Lost SPECTRUM ENVIRONMENTAL SOLUTIONS, LLC 1

Space product assurance

Jaap de Zeeuw Restek Corporation, Middelburg, The Netherlands. Copyrights: Restek Corporation

Pharmaceutical Grade Nitrogen & Gardner Denver / CompAir PSA Nitrogen Gas Generation Systems

5890II GC Standard Operating Procedure 9/2/2005

A New GC/MS System Designed for Helium Carrier Gas Conservation

Best Practice for Identifying Leaks in GC and GC/MS Systems

CHEMTRACE Fremont Blvd. Fremont, CA 94538, Tel: (510) Fax: (510)

Now it is. easy to switch. CHS TM Steroid Profiling kit and software. Brochure not for distribution in the USA and Canada

Arizona Department of Public Safety. And Phoenix Police Department. Oleoresin Capsicum Staff Study

Ghost Peaks: How to Fix a Haunting Problem. Jacob A. Rebholz Teledyne Tekmar VOC Product Line Manager

OMCL Network of the Council of Europe QUALITY ASSURANCE DOCUMENT

Advancements in Gas Chromatography Analyzers - Keeping up with New Technology. Chuck Runkle Gas Phase Product Specialist ASTS June 2013

ISO 7941 First edition

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Practical approach and problems in in-situ RGA calibration

Hiden QIC Series Gas Analysers Real-time gas analysis systems

Agilent 7800 ICP-MS. Specifications and Typical Performance. Fast track metals analysis with Solution-Ready ICP-MS

Gas Chromatographic Applications of the Dielectric Barrier Discharge Detector

Gas Clean. Filters. Delivering Clean Gases for GC and GC/MS Operation

ASTM WK Standard Test Method for Dissolved Gases. Anne Jurek Applications Chemist

Agilent Dimension Software for ELSD User Manual

LEVANT WORMSEED FOR HOMOEOPATHIC PREPARATIONS CINA FOR HOMOEOPATHIC PREPARATIONS

Using the Agilent 6890N GC/MS for Sampling Volatile Organic Compounds. Bob Castro, B.S. Chemical Eng., M.S. Environmental Eng.

FROG-4000 TM Chemical Analysis System

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Impact of Air Leaks on the Productivity of GC and GC/MS Systems

LC-MS-Guided Isolation of Insulin Secretion-promoting. Monoterpenoid Carbazole Alkaloids from Murraya

Addressing the World Shortage of Helium

High Automation of Thermo Scientific FlashSmart CHNS/O Analyzer using the MultiValve Control (MVC) Module

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES

A Column-Flow Independent Configuration for QuickSwap. Application. Authors. Abstract. Introduction

CHEM254 #4 The Synthesis of a Tertiary Alcohol Using a Pre-Made Grignard Reagent 1

Acclaim RSLC. (Rapid Separation Liquid Chromatography)

This standard is due for Five Year Review. This process is required by the SEMI Regulations to ensure that the standard is still valid.

3. Coupled Techniques in Thermal Analysis

Carrier Gases in Capillary GC

Svensk läkemedelsstandard

AKTA pure 25 New Owner s Intro

Transcription:

Available online wwwjocprcom Journal of Chemical and Pharmaceutical Research, 4, 6(4):648-64 Research Article ISSN : 97-7384 CODEN(USA) : JCPRC Determination of capsaicinoid profile of some peppers sold in Nigerian markets N C Nwokem *, 2 C O Nwokem, 2 Y O Usman, O J Ocholi, 2 M L Batari and 3 A A Osunlaja Department of Chemistry, Ahmadu Bello University, Zaria, Nigeria 2 National Research Institute for Chemical Technology, Zaria, Nigeria 3 Umar Suleiman College of Education, Gashua, Nigeria ABSTRACT The capsaicinoid profile of six different peppers sold in Nigerian markets was determined by Gas Chromatography- Mass Spectrometry The capsaicinoids were extracted from the peppers using methanol as extractant and analyzed without need for derivatization A total of eight (8) capsaicinoids were identified and quantitated:, Dihydrocapsaicin,, Norcapsaicin,, and Nornordihydrocapsaicin though, not fully present in all the varieties Dihydrocapsaicin,,, and Nornordihydrocapsaicin are isomers Seven were identified in the Cameroun pepper variety, six in Zaria atarugu and Miango, and five in each of the remaining varieties In all the peppers analyzed, capsaicin had the highest relative concentration, which ranged from 273% in the Cameroun variety to 4938% in the Zaria atarugu variety The sum of the relative concentrations of capsaicin and dihydrocapsaicin ranged from 473% in the Miango variety to 873% in the Zaria atarugu variety Keywords: oids, Gas Chromatography-Mass Spectrometry, Methanol, Pepper INTRODUCTION Peppers are widely used in many parts of the world as a result of their valued sensory attributes; colour, purgency and aroma Capsicum fruits which vary mainly in colour, size, shape, flavor, and pungency find greatest application in the food industry; as a coloring and flavoring agent in sauces, soups, processed meats, snacks, candies, soft drinks, and alcoholic beverages either in the ground form, or as an oleoresin (concentrated extract) oids, also known as the phenylalkylamide alkaloid group, are the group of compounds responsible for the heat sensation in Capsicum fruits (peppers) The compounds are found in many foods and seasonings They are also used as pest repellants in agriculture, and there is interest in using them as synergists with organophosphate insecticides [] Because of their wide use, determination of the capsaicinoid profile of peppers is desirable oids are present in varieties of peppers in different amounts Pure capsaicin is a white crystalline compound that melts at 6 C and is volatile above this temperature It produces a dangerous and irritating vapor In commercial capsicums, capsaicin generally comprises 33-9%, dihydrocapsaicin accounts for -%, Nordihydrocapsaicin is 7-%, and the remainder is less than % of the capsaicinoids [9] 648

N C Nwokem et al J Chem Pharm Res, 4, 6(4):648-64 The Scoville organoleptic test was used for the determination of pepper pungency, but has since been replaced with chromatographic methods which are considered more reliable and accurate In recent times, High Performance Liquid Chromatography has been the method of choice for the quantitation of capsaicinoids by most workers [, 2, 3 and ] Gas Chromatographic methods reported in the literature employ the use of packed chromatography columns and require sample cleanup step prior to analysis, and in most cases, there was need for derivatization [, 8 and 7] Recently, a group of workers, Thomas [] carried-out an investigation on the capsaicinoid content of some peppers and reported the detection of isomers for five capsaicinoids However, the isomers could not be quantitated due to non-availability of analytical standards The object of this work was to identify the capsaicinoids present in some peppers sold in retail markets in Nigeria and determine the relative concentration of the capsaicinoids by the percentage area of the peaks associated with the deprotonated molecular ion [M-H] EXPERIMENTAL SECTION Peppers used for this study were purchased from local retail markets in the region where they were grown, except the Cameroun pepper The peppers used in the study include Atarugu, Zaria (Capsicum annuum var), Tatase Zaria (Capsicum annuum), Yellow pepper, Nsukka (Capsicum chinense), Atarugu, Miango (Capsicum annuum var) and Atarugu, Makurdi (Capsicum annuum var) After removal of the stalk, the fresh pepper samples were washed with distilled water to remove adhering soil and dirt and then dried with a clean piece of cloth before each analysis The Cameroun dry pepper samples were dried in an oven at 6 C for 6hrs, ground using a mortar and pestle and passed through a sieve (mm) and stored in a dessicator until required for analysis Extraction of capsaicin from the pepper samples was done using the method described by Collins [2] with slight modifications GCMS Analysis Conditions A Gas Chromatograph-Mass Spectrometer, (GCMS QP-, Shimadzu Analytical Instruments) was used for analyzing the samples Injections were performed by AOC-i Auto injector (Shimadzu, Japan) A Rtx-MS column (% diphenyl, 9% dimethylpolysiloxane stationary phase), m mm id (Restek, USA) was used The column temperature program is as follows 6 C for min, C/min to 4 C for min, C/min to 28 C for min (93 min total) The carrier gas used was helium with a flow rate of 6ml/min the detector was a quadrupole mass spectrometer (MS) with EI ionization at 7eV in full scan mode RESULTS AND DISCUSSION Identification of other capsaicinoids present in the peppers analyzed was only by comparing the mass spectra generated by the peak associated with the deprotonated molecular ion peak [M-H] with literature due to the nonavailability of standard compounds The relative concentration of the other capsaicinoids detected was determined by % area of the peaks associated with the deprotonated molecular ion [M-H] The relative concentrations of the capsaicinoid analogues in the pepper varieties analyzed are summarized in Table 44 Also, Figures 3 to 8 show the number and relative concentrations of the capsaicinoid analogues identified in each of the varieties The results reveal the identification of a total of eight (8) capsaicinoids, capsaicin, dihydrocapsaicin, dihydrocapsaicin 2, norcapsaicin, nordihydrocapsaicin, nordihydrocapsaicin 2, homodihydrocapsaicin and nornordihydrocapsaicin based strictly on their mass spectra All the capsaicinoids are commonly reported in literature except nornordihydrocapsaicin, which was only reported by Thomas [] Identification of nornordihydrocapsaicin is based on the fact that the difference between it and nordihydrocapsaicin is CH 2, ie 4 amu which is in agreement with report by Thomas [] Two peaks which correspond to and dihydrocapsaicin 2; and nordihydrocapsaicin and nordihydrocapsaicin 2 were identified for dihydrocapsaicin and nordihydrocapsaicin respectively Similar mass spectral patterns were observed for each pair These pairs correspond to isomers as the occurrence of isomers of capsaicinoids has been reported by several workers [2, 4 and ] The three (3) major capsaicinoids; capsaicin, dihydrocapsaicin, and nordihydrocapsaicin were identified in all the pepper varieties used in the study They contribute over 9% of the total capsaicinoids in all but the miango variety (Table ) In the Zaria tatashe variety, the contribution was approximately % as no other capsaicinoid was identified The minor capsaicinoid, norcapsaicin identified in this study has been previously reported by other workers [2] Seven capsaicinoids were identified in the Cameroun variety, six in Zaria atarugu and Miango, and five in each of the remaining varieties Differences in capsaicinoid profile within a given variety are well established 649

N C Nwokem et al J Chem Pharm Res, 4, 6(4):648-64 and can be caused by variations in growing conditions or maturity [] Even peppers from the same plant can vary in their capsaicinoid profiles due merely to differences in post-harvest ripening conditions [] The mass spectra generated for each of the capsaicinoids generally agree with literature [] The capsaicinoids all had similar fragmentation patterns as the most stable portions of the molecules are identical These fragments include m/z = 4, 94,, 22, 36, and 94 The seven (7) capsaicinoids identified in miango pepper are shown in the chromatogram labeled Figure The spectra for the capsaicinoids identified in miango pepper are shown in Figure 2 below, where the molecular ion peak in each spectrum, corresponds to the deprotonated molecular ion peak [M-H] In all the peppers analyzed, capsaicin had the highest relative concentration, which ranged from 273% in the Cameroun variety to 4938% in the Zaria atarugu variety The sum of the relative concentrations of capsaicin and dihydrocapsaicin ranged from 473% in the Miango variety to 873% in the Zaria atarugu variety These values do not entirely corroborate the report [6] that capsaicin and dihydrocapsaicin account for ~ 9% of the total capsaicinoids in pepper fruit This may be due to the fact that quantitation in this case, was based on relative concentrations The chromatograms obtained for each of the pepper samples also clearly reveal that the capsaicinoids eluted according to the length of their aliphatic side chain That is, the capsaicinoids elute according to increasing molecular weight; which is also in agreement with reports by other workers [4, 2 and ] Table : Relative Concentrations of oids in the Peppers (% Area of Peak) Variety NNDHC NDHC NDHC 2 CAP DHC DHC 2 HDHC NCAP CAP + DHC+ NDHC "Zaria atarugu" 24 72 34 4938 348 384 28 ND 966 Makurdi ND 86 8 4347 2224 43 3 ND 969 Miango 924 27 367 29 246 63 ND 8423 "Zaria tatase" ND 688 6 3426 73 276 ND ND 9999 Nsukka Yellow ND 4 884 48 222 78 82 ND 989 Cameroun ND 2342 78 273 282 62 869 77 93 NNDHC Nornordihydrocapsaicin NDHC Nordihydrocapsaicin CAP HDHC NCAP Norcapsaicin ND - not detected Figure : Chromatogram of Miango pepper with peaks representing capsaicinoids labeled to 7 6

N C Nwokem et al J Chem Pharm Res, 4, 6(4):648-64 Figure 2: Mass spectra of the various capsaicinoids identified in Miango pepper 6

N C Nwokem et al J Chem Pharm Res, 4, 6(4):648-64 Molecular weights of oids and the deprotonated molecular ion peak [M-H] g/mol [M-H] = 4 Dihydrocapsaicin 7 g/mol [M-H] = 6 93 g/mol [M-H] = 292 Nornordihydrocapsaicin 279 g/mol [M-H] = 278 Norcapsaicin 29 g/mol [M-H] = 29 32 g/mol [M-H] = 3 "Atarugu" (Zaria) Relative concentration, Area % 6 4 Nornordihydrocapsaicin Figure 3 Chart Showing the Relative Concentrations of the oids identified in the Atarugu (Zaria) Pepper "Tatase" (Zaria) 4 Relative concentration, Area % 3 Figure 4 Chart Showing the Relative Concentrations of the oids identified in the Tatase (Zaria) Pepper 62

N C Nwokem et al J Chem Pharm Res, 4, 6(4):648-64 Cameroun Relative concentration, Area % Norcapsaicin Figure Chart Showing the Relative Concentrations of the oids identified in the Cameroun Pepper Yellow Pepper (Nsukka) Relative concentration, Area % 4 4 3 Figure 6 Chart Showing the Relative Concentrations of the oids identified in the Yellow Pepper (Nsukka) "Atarugu" (Makurdi) Relative concentration, Area % 4 Figure 7 Chart Showing the Relative Concentrations of the oids identified in the Atarugu (Makurdi) Pepper 63

N C Nwokem et al J Chem Pharm Res, 4, 6(4):648-64 Miango 3 Relative concentration, Area % Nornordihydrocapsaicin Figure 8 Chart Showing the Relative Concentrations of the oids identified in the Atarugu (Miango) Pepper CONCLUSION This study reports the identification of eight capsaicinoids in some peppers sold in retail markets in Nigeria This includes the capsaicinoid Nornordihydrocapsaicin which of all literature consulted, was only reported by Thomas et al These results, though relative, show that capsaicin, is the most abundant capsaicinoid in pepper However, there is need for further work on the quantitation of individual capsaicinoid based on the use of external standards Acknowledgement The authors acknowledge the support of the management of National Research Institute for Chemical Technology, Zaria, Kaduna State, for the use of its facilities especially the Gas Chromatograph-Mass Spectrometer REFERENCES [] V Attuquayefio; K Buckle J Agric Food Chem 987, 3, 777-779 [2] MD Collins; L Mayer-Wasmund; PW Bosland HortSci 99,, 37-39 [3] T Cooper; J Guzinski; C Fisher J Agric Food Chem 99, 39, 23-26 [4] W Hawer; J Ha; J Hwang; Y Nam J Food Chem 994, 49: 99-3 [] V Huffman; E Schadle; B Villalon; E Burns J Food Sci 978, 43, 89-8 [6] S Kosuge; M Furuta J Agric Biol Chem 97, 34: 248-6 [7] A Krajewska; J Powers J Offic Anal Chem 987, 7: 926-928 [8] J Jurenitsch; M David; F Heresch; W Kubelka Planta Med 979, 36: 6-67 [9] G Reineccius Source Book of Flavors, 2nd edition, Chapman and Hall, New York, USA, 994, 267-273 [] BV Thomas; AA Schreiber; CP Weisskopf J Agric Food Chem 998, 46 (7), 26-2663 [] J Yao; M Nair; A Chandra J Agric Food Chem 994, 42, 3- [2] PM Gannett; DL Nagel; PJ Reilly J Org Chem 998, 3(2), 64-7 64