LEA_EN_PZL Dynamometric Scale. Instruments and Systems for Geotechnical and Structural Monitoring

Similar documents
Single and double acting, magnetic, self-centering Bores: ø 16, 20, 25, 32, 40 mm

Successful completion of the course leads to the award of the Technical Training Solutions Certificate of Competence 510: Instrumentation.

C-Flow Coriolis Mass Flow Meters

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

[Instruments for vacuum measurement, checking and adjustment] 3

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

CONTROL and INSTRUMENTATION

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Level MEASUREMENT 1/2016

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.:

Instrumentation & Data Acquisition Systems

pneumatic power clamps

Lab 1c Isentropic Blow-down Process and Discharge Coefficient

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

Heavy Duty Dissolved Oxygen Meter

Design Features. General Description

Pneumatic Outflow Control

deltaflowc deltaflowc Venturi or Probe

Electronic Volume Correctors

Multiple Pressure Booster Systems With Variable Speed Controller Type BL

Visualize Nitrogen Gas Consumption

2-JAW SELF-CENTERING PARALLEL PNEUMATIC GRIPPER (SERIES HS)

Inductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Coriolis Mass Flow Meter

Precision level sensing with low-pressure module MS

The Ins and Outs of I/P Transducers

HumiSys HF High Flow RH Generator

Fluid Machinery Introduction to the laboratory measurements

Instruction Manual BA90 Precision Barometer

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

_ pressure transducers. User Manual

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

Pressure Measurement. Introduction. Engr325 Instrumentation. Dr Curtis Nelson 3/12/18

Variable Area Flow Meters

2-jaw self-centering pneumatic parallel gripper (series SX)

STARLOG. Capacitive Water Depth Probe

ACV-10 Automatic Control Valve

How to specify a product. Process Sensors and Mechanical Instruments

Ultrasonic level transmitter and indicator

Pressure Calibrators. Series PC..., PM...

Digital dead-weight tester Model CPD8500

Digital deadweight tester Model CPD8500

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Properties of Fluids SPH4C

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features

LUGB Vortex Flowmeter

Hidrostatic Level DATASHEET

TEK-THERMAL 1700B. Thermal Mass Flowmeter. FLOW. Technology Solutions

Reliability and flexibility in a compact design

TH-1800-T TRX-700-CNG Converter

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

PS-525 Pitot-Static/Air Data Tester. OPERATION AND MAINTENANCE MANUAL For Models PS-525 and PS-525A

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

deltaflowc deltaflowc Gas Massflowmeter Venturi- and Probe Type

Magnetic level switch type MR783 Instruction Manual

SCAM T.P.E. WATER TREATMENT SYSTEM SWT- AP AUTOMATIC PURGE

INSTRUCTION MANUAL. 840 Transmitter. Loop Powered Dissolved Oxygen Transmitter

TSE Blood Pressure Monitor Invasive series

Gas density monitor With integrated transmitter Model GDM-100-TI

TECHNOLOGIES. M Series. Positive return metering pumps [API675]

Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids

Operating Instructions Part No

SEMEM3-78 Testing and calibrating instrumentation and control equipment and circuits

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

PRP. Pneumatic parallel gripper with rotator PRP

JOLLY2. Installation user s manual. 6 different operating modes selectable. version 3.3. DATA TO BE FILLED OUT BY THE INSTALLER (Page 1)

Application of CHE100 in Frequency Conversion Alteration of Air Compressor System

REF Description Picture Technical data Page

AMS 2710 PCB pressure sensor module with V output

MANUAL KPS Pressure Control Valve

HYBRID STEPPING MOTORS HY / HS / HN Series

TGD-L (LP) Tank Gauging Device TGD L (Level) TGD LP (Level Pressure) Main features:

The Discussion of this exercise covers the following points: Pumps Basic operation of a liquid pump Types of liquid pumps The centrifugal pump.

MODEL GT820 OXYGEN SENSOR

Additel 761 Automated Pressure Calibrators

Truck-mounted Mass Flow Metering for LPG Delivery

Target disk flowmeter Series DP. Instructions manual DP65 DP500. R-MI-DP Rev.: 4 English version

PRESSURE SENSOR - ABSOLUTE (0 TO 700 kpa)

Description Total stroke Maximum Recommended Page in mm gripping force in N workpiece weight in kg

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

High Pressure Breathing Air Compressors

Pneumatic high-pressure controller Model CPC7000

Flow metering in gases Introduction to COMBIMASS family

Carbo Online CO 2 Analyzer for Beverages. ::: Great People Great Instruments

Air Operated Hydraulic Pumping Systems to 50,000 psi

3.0 Pressure Transmitter Selection

Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor

OEM Manual. MODEL ½ Digit DRUM SCALE

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

HYDRAULICS. H89.8D - Hydraulic Bench

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

New! ProFlow. Sliding Vane Meters DN (½ - 2 ) _ 142. Product Bulletin

Varea-Meter Flowmeters. For Metering and Controlling Flows of Process Fluids

WL16 WATER LEVEL LOGGERS Submersible pressure transducer and USB datalogger combination

Improving distillation tower operation

Transcription:

LEA_EN_PZL8001001 Dynamometric Scale

LEA_EN_PZL8001001 Dynamometric Scale Description _ The dynamometric scale is a precise, reliable and rugged instrument. The instrument was installed on different dams in Italy and abroad few decades ago and still maintains its technical and functional characteristics with minimum maintenance and few interventions of repair. The dynamometric scale is a system designed to detect, record and transmit, at a distance, water levels measured in large basins; they function with an elevated accuracy and extended measurement range. Two versions are available. They differ in their system of application: B) Pneumatic version, with the installation of the measurer at the same height as the top of the dam; a pressure measurement is performed at the altitude of the lowest level to be measured. In both cases, the hydrostatic pressure is measured by a precision scale, with a mobile roman, that takes the measurement with a sensibility of +/- 1 cm of water column, with a range of 80 metres (in the standard version). Our datalogger DAQ3000 allows data restitution at distance. A) Hydrostatic version, cfor installation with hydrostatic pressure measurements, where the water level measurer is placed low, at the same height of the minimum level to be measured.

Applications _ The dynamometric scale is used to measure the water level in large dams where it is necessary to have high accuracy on wide ranges. The instrument reaches accuracies of ±1cm of water column for levels up to 80 meters and of ±2 cm for levels up to 140 meters. Features and benefits _ High degree of ruggedness High reliability Great resistance Long life Easy maintenance Easy Repair Great accuracy Certainty of data Absence of drifts and over time and with temperature Measurement principle _ The dynamometric scale focuses its measuring principle on a primary lever. The charge of the water to be measured works on one of the arms of the lever, by means of a pressure/force system of transduction. A mobile roman, directed by a micrometric screw, runs along the lever s arm that is opposite the charge application. The equilibrium position shows the measure of the applied charge, and therefore of the level to be measured. When the system is at rest, the end of the arm of the lever on which the roman acts is in equilibrium in the action field of two magnetic sensors. Each movement away from the lever s equilibrium position causes an imbalance in the magnetic circuit; this activates the command motor of the micrometric screw by means of a special electronic circuit, which in turn moves the mobile roman until it regains its electrical and mechanical equilibrium. A mechanical counter, with the same axial as the micrometric screw, counts the number and the fraction of turns necessary to bring the mobile roman to the new position of equilibrium. The reduction ratio between counter and screw is enough to reestablish the value of the level, a value which is expressed directly in centimetres.

The system is also equipped with an absolute encoder in Gray code, 13 bits, which allows the digitalization of the data for remote reading. The system is designed for a maximum reliability and accuracy. For example, the pressure/force transduction is constructed with a sliding piston with a calibrated diameter, maintained in continuous rotation thanks to an agitating motor. The piston works in oil and is subjected to the pressure of the water beater to be measured. In this way the system has virtually no inertia or friction. Knife systems have been used, both for the fulcrum and the junctions of the roman and the piston; we guarantee that there is no phase displacement between the micrometric screw, the mechanical numerator and the absolute encoder. T Magnetic Sensors V Micrometric Screws R Balancing Weight E Absolute Encoder A Pivot (Main knife) C Knife for the load application N Mechanical Counter for local reading P Piston/Cylinder (transducer pressure/force) M Engine for piston rotation PP Pressure to be measured Not having any contacts, the system used to locate the position of the arm ensures an elevated reliability in every condition. As already mentioned, a 13 bit absolute Gray encoder is used for remote reading; this ensures a resolution of 1cm over a range of 81 m. The scale is equipped with magnetic end courses for safety. The entire group is contained in a hermetically sealed case and maintained at constant temperature by a thermostatheating element. The dynamometric scale system allows the measurement of levels both with direct hydrostatic pressure measurements and pneumatic pressure measurements. The basic instrument is the same for both versions; these only differ in their way of measuring pressure, as can be seen in the illustrative designs. In the protection container of the mechanical groups, both the electronic group to control the sensors and the various components for regulation and protection are present. These are, for example: the fuse group, the control thermostat for the heater, the chart for data serialization (optional). The apparatus is already calibrated; therefore the operations to be performed on installation are limited to those regarding the connection of the connectors for signal and power supply transmission. The data for the transmission is converted into serial RS232 or RS485.

HYDROSTATIC VERSION Necessary material: 1. Scale 2. Hydrostatic pressure taking group 3. Restraint flange 4. 2 Tube 5. Hydrostatic pressure measuring group For the connection between scale 4) and the acquisition unit it is used a multiple screened cable 4c. PNEUMATIC VERSION Necessary material: 1. Dynamometric scale 2. Compressed air feeding group 3. Pressure regulation frame 4. Pneumatic taking pressure group 5. Copper tube 10/12 mm 6. Pressure measuring bell Groups 1,2 and 3 are normally installed at the top of the dam, at a height near that of the maximum level of the reservoir. The connection between the scale and the acquisition unit is ensured by means of copper tubes, that have a diameter of 10/12mm. The connectors necessary to join the various groups are included with the respective units. Groups 1) and 2) are generally placed in alarm situations. To join scale 4) and the ML81B unit, a multiple screened cable is used (19c for parallel transmission, 4c for serial transmission).

Technical features Measuring Range 80 m or 140 m Encoder Resolution 1 cm (range 80m); 2cm (range 140m) Sensibility 1 cm (range 80m); 2cm (range 140m) Accuracy ± 1cm on all range; ± 2 cm on all range Standard output code: 13 bit parallel Gray disconnected Serial Gray with transmission in current loop 0/20mA Power supply voltage: Standard : 24Vca ±10%; 50 Hz; Optional : 110/220 Vca ±10% Consumption with heaters switched off Maximum consumption with heaters switched on Tracking rate of the level change 50VA 100VA 22 cm/min (66cm/min) Technical assitance If you have any requests or questions about our instruments or if you have special needs that require different solutions from the standard, please contact us. Our team will provide all the necessary information and will be very happy to work with you to study, develop and customize instruments and solutions suitable for your specific needs.

LEA_EN_PZL8001001 Dynamometric Scale The product information may be subject to variations at any time. Please carefully check the release and contact Pizzi Instruments for further details. Pizzi Instruments S.r.l. Tel/Fax: +39 055 6810722 Via di Ripoli 207/F info@pizzi-instruments.it 50126 - Florence - Italy