DES Waste Management Division 29 Hazen Drive; PO Box 95 Concord, NH
|
|
- Lee Walton
- 5 years ago
- Views:
Transcription
1 DES Waste Management Division 29 Hazen Drive; PO Box 95 Concord, NH SHALLOW SOIL SAMPLING RESULTS REEDS FERRY ELEMENTARY SCHOOL Merrimack, NH NHDES Site #: Project Type: HAZARDOUS WASTE DISCHARGE PROJECT Project Number: Prepared For: Saint Gobain Performance Plastics 4 McCaffrey Street Hoosick Falls, NY 90 Prepared By: C.T. Male Associates 50 Century Hill Dr. Latham, NY Phone Number: (58) Contact Name: Kirk Moline Contact k.moline@ctmale.com Date of Report: October 27, 6 Cover Sheet for Reports Template - Revised January
2 C.T. MALE ASSOCIATES Engineering, Surveying, Architecture & Landscape Architecture, D.P.C. 50 Century Hill Drive, Latham, NY FAX October 27, 6 Mr. Thomas M. Touseau Reeds Ferry Elementary School 36A McElwain Street Merrimack, New Hampshire Re: Soil Sampling Results Reeds Ferry Elementary School Merrimack, N.H CT Male Project No Dear Mr. Touseau: With approval from the New Hampshire Department of Environmental Services (NHDES), C.T. Male Associates Engineering, Surveying, Architecture & Landscape Architecture, D.P.C. (C.T. Male) has completed an investigation of the surface and nearsurface soils within your property. The investigation was completed in accordance with C.T. Male s Work Scope titled Surface Soil Sampling, Towns of Merrimack and Litchfield, NH, dated April 25, 6 and approved by NHDES on April 27, 6. As shown on the attached Site Map, soil samples were collected from pre-selected locations within the property. Soil samples were collected from the following depth intervals: ground surface to 6 ; 6 to 2 ; 2 to 8 ; and 8 to 24, unless hand auger refusal was encountered at a particular sampling interval. Where auger refusal was encountered, it was due to the presence of an obstruction such as large gravel or cobbles. The collected soil samples were shipped to and analyzed by Eurofins Lancaster Environmental Laboratories (ELLE) of Lancaster, Pennsylvania under a chain of custody document. Additionally, quality assurance/quality control (QA/QC) samples were collected during the sampling event and submitted along with the soil samples. The soil and QA/QC samples were analyzed for Perfluorinated Compounds (PFCs) by EPA Method 537 Rev. - Modified, Total Organic Carbon (TOC) and moisture content. The individual PFCs analyzed by ELLE and minimum reporting limits (MRL) are as follows: Individual PFCs Perfluorooctanoic acid (PFOA) Perfluorooctane sulfonate (PFOS) MRL Architecture & Building Engineering Civil Engineering Energy Services Environmental Services Survey & Land Services
3 C.T. MALE ASSOCIATES October 27, 6 Thomas Touseau Page - 2 Individual PFCs Perfluorobutanesulfonic acid (PFBS) Perfluoroheptanoic acid (PFHpA) Perfluorohexanesulfonic acid (PFHxS) Perfluorononanoic acid (PFNA) Perfluorohexanoic acid (PFHxA) Perfluorodecanoic acid (PFDA) Perfluoroundecanoic acid (PFUnA) Perfluoroudodecanoic acid (PFDoA) Perfluorotridecanoic acid (PFTriA) Perfluorotretradecanoic acid (PFTA) Notes: denotes nanogram per gram or parts per billion (ppb) MRL Following receipt of the final analytical reports from ELLE, the data was subjected to validation by an independent third party data validator. The analytical results for the soil samples and QA/QC samples are presented in the attached Shallow Soil Sample Analytical Table. The data presented is considered to be validated. During the validation process, the data is independently reviewed and qualified if necessary, based on the validation criteria established by the United States Environmental Protection Agency (USEPA). The notes within the table define the data validation qualifiers to the data. As presented in the attached table, the analytical results are compared to the NH Direct Contact Risk Based (DCBR) Concentration in Soil per the NH Environmental Health Program (EHP) - NH DCRB concentration in soil (Consoil) Screening Value from NHDES Memorandums dated June 7, 6 and June 28, 6. NH EHP has developed soil criteria values for PFOA and PFOS. The values established for PFOA and PFOS are as follows: PFOA: 500 (parts per billion) for a young child (residential) PFOS: 500 (parts per billion) for a young child (residential) As presented in the attached table and laboratory report, the results for each of the soil samples collected from your property are below the NH EHP PFOA and PFOS soil criteria values. The full data deliverable package from the laboratory and the data validation report will be provided in the Sensitive Receptor Summary Report submitted to NHDES and available on OneStop at
4 C.T. MALE ASSOCIATES October 27, 6 Thomas Touseau Page - 3 If you have any questions or comments regarding your results, please feel free to contact Lea Anne Atwell at NHDES at (603) Sincerely, C.T. MALE ASSOCIATES Kirk Moline Managing Geologist Attachment: Site Map w/sampling Locations Shallow Soil Sampling Analytical Table Laboratory Report c: Lea Anne Atwell, P.G. NHDES
5 inch = 0 feet Project Number:6.626 Data Source: NH GIS Clearinghouse, World Imagery Projection: State Plane NH NAD 83 (ft.) Date: October 26, 6 File: ReedsFerryElementary.mxd GIS: CHay FT Legend!. Soil Sampling Locations Note: The locations and features depicted on this map are approximate and do not represent a field survey. Reeds Ferry Elementary School Soil Sampling Locations Towns of Merrimack and Litchfield Hillsborough County, New Hampshire
6 SHALLOW SOIL SAMPLE ANALYTICAL TABLE REEDS FERRY ELEMENTARY SCHOOL MERRIMACK, NEW HAMPSHIRE Validated Client Sample ID Lab Sample ID A. Bball Outfld# 0 to A. Bball Outfld# 6 to A. Bball Outfld# 2 to A. Bball Outfld# 8 to B. Bball OutFld #2 0 to PARAMETER Units Concsoil* Result Q MDL Validated? Result Q MDL Validated? Result Q MDL Validated? Result Q MDL Validated? Result Q MDL Validated? Perfluorobutanesulfonic acid (PFBS) 0.6 U 0.6 Y 0.60 U 0.60 Y 0.60 U 0.60 Y 0.59 U 0.59 Y 0.73 U 0.73 Y Perfluorodecanoic acid (PFDA) 0.25 U 0.25 Y 0.24 U 0.24 Y 0.24 U 0.24 Y 0.24 U 0.24 Y 0.29 U 0.29 Y Perfluorododecanoic acid (PFDoA) 0.49 U 0.49 Y 0.48 U 0.48 Y 0.48 U 0.48 Y 0.47 U 0.47 Y 0.58 U 0.58 Y Perfluoroheptanoic acid (PFHpA) 0.37 U 0.37 Y 0.36 U 0.36 Y 0.36 U 0.36 Y 0.36 U 0.36 Y 0.44 U 0.44 Y Perfluorohexanesulfonic acid (PFHxS) 0.6 U 0.6 Y 0.60 U 0.60 Y 0.60 U 0.60 Y 0.59 U 0.59 Y 0.73 U 0.73 Y Perfluorohexanoic acid (PFHxA) 0.25 U 0.25 Y 0.24 U 0.24 Y 0.24 U 0.24 Y 0.24 U 0.24 Y 0.29 U 0.29 Y Perfluorononanoic acid (PFNA) 0.28 J 0.25 Y 0.24 U 0.24 Y 0.24 U 0.24 Y 0.24 U 0.24 Y 0.29 U 0.29 Y Perfluorooctanesulfonic acid (PFOS) J 0.86 Y 0.84 U 0.84 Y 0.84 U 0.84 Y 0.83 U 0.83 Y 2.2 J.0 Y Perfluorooctanoic acid (PFOA) Y Y Y Y Y Perfluorotetradecanoic acid (PFTA) 0.37 U 0.37 Y 0.36 U 0.36 Y 0.36 U 0.36 Y 0.36 U 0.36 Y 0.44 U 0.44 Y Perfluorotridecanoic Acid (PFTriA) 0.74 U 0.74 Y 0.72 U 0.72 Y 0.72 U 0.72 Y 0.7 U 0.7 Y 0.87 U 0.87 Y Perfluoroundecanoic Acid (PFUnA) 0.37 U 0.37 Y 0.36 U 0.36 Y 0.36 U 0.36 Y 0.36 U 0.36 Y 0.44 U 0.44 Y Moisture, Percent NA NA NA NA NA Total Organic Carbon Y Y Y Y Y Client Sample ID Lab Sample ID B. Bball OutFld #2 6 to C. Lacrosse Fld# 0 to C. Lacrosse Fld# 6 to C. Lacrosse Fld# 2 to C. Lacrosse Fld# 8 to PARAMETER Units Concsoil* Result Q MDL Validated? Result Q MDL Validated? Result Q MDL Validated? Result Q MDL Validated? Result Q MDL Validated? Perfluorobutanesulfonic acid (PFBS) 0.64 U 0.64 Y 0.62 U 0.62 Y 0.6 U 0.6 Y 0.60 U 0.60 Y 0.63 U 0.63 Y Perfluorodecanoic acid (PFDA) 0.26 U 0.26 Y Y 0.24 U 0.24 Y 0.24 U 0.24 Y 0.25 U 0.25 Y Perfluorododecanoic acid (PFDoA) 0.5 U 0.5 Y Y 0.49 U 0.49 Y 0.48 U 0.48 Y 0.50 U 0.50 Y Perfluoroheptanoic acid (PFHpA) 0.38 U 0.38 Y 0.37 U 0.37 Y 0.37 U 0.37 Y 0.36 U 0.36 Y 0.38 U 0.38 Y Perfluorohexanesulfonic acid (PFHxS) 0.64 U 0.64 Y 0.62 U 0.62 Y 0.6 U 0.6 Y 0.60 U 0.60 Y 0.63 U 0.63 Y Perfluorohexanoic acid (PFHxA) 0.26 U 0.26 Y 0.32 J 0.25 Y 0.24 U 0.24 Y 0.35 J 0.24 Y 0.3 J 0.25 Y Perfluorononanoic acid (PFNA) 0.26 U 0.26 Y Y Y 0.24 U 0.24 Y 0.25 U 0.25 Y Perfluorooctanesulfonic acid (PFOS) U 0.89 Y Y Y.5 J 0.84 Y 0.88 U 0.88 Y Perfluorooctanoic acid (PFOA) Y Y Y Y Y Perfluorotetradecanoic acid (PFTA) 0.38 U 0.38 Y 0.49 J 0.37 Y 0.37 U 0.37 Y 0.36 U 0.36 Y 0.38 U 0.38 Y Perfluorotridecanoic Acid (PFTriA) 0.77 U 0.77 Y 0.74 U 0.74 Y 0.73 U 0.73 Y 0.72 U 0.72 Y 0.75 U 0.75 Y Perfluoroundecanoic Acid (PFUnA) 0.38 U 0.38 Y 0.73 J 0.37 Y 0.37 U 0.37 Y 0.36 U 0.36 Y 0.38 U 0.38 Y Moisture, Percent NA NA NA NA NA Total Organic Carbon Y Y Y Y Y Client Sample ID Lab Sample ID D. Lacrosse Field #2 0 to D. Lacrosse Field #2 6 to E. Reeds Ferry Nature Trail 0 to E. Reeds Ferry Nature Trail 6 to F. Playground 0 to PARAMETER Units Concsoil* Result Q MDL Validated? Result Q MDL Validated? Ferry Nature T Q MDL Validated? Result Q MDL Validated? Result Q MDL Validated? Perfluorobutanesulfonic acid (PFBS) 0.60 U 0.60 Y 0.60 U 0.60 Y 0.72 U 0.72 Y 0.66 U 0.66 Y 0.9 U 0.9 Y Perfluorodecanoic acid (PFDA) Y Y 0.29 U 0.29 Y 0.27 U 0.27 Y 0.36 U 0.36 Y Perfluorododecanoic acid (PFDoA) Y Y 0.58 U 0.58 Y 0.53 U 0.53 Y 0.73 U 0.73 Y Perfluoroheptanoic acid (PFHpA) 0.36 U 0.36 Y 0.36 U 0.36 Y 0.53 J 0.43 Y 0.40 U 0.40 Y 0.54 U 0.54 Y Perfluorohexanesulfonic acid (PFHxS) 0.60 U 0.60 Y 0.60 U 0.60 Y 0.72 U 0.72 Y 0.66 U 0.66 Y 0.9 U 0.9 Y Perfluorohexanoic acid (PFHxA) Y Y 0.32 J 0.29 Y 0.27 U 0.27 Y 0.48 J 0.36 Y Perfluorononanoic acid (PFNA) Y Y 0.33 J 0.29 Y 0.27 U 0.27 Y 0.39 J 0.36 Y Perfluorooctanesulfonic acid (PFOS) Y Y.0 U.0 Y 0.93 U 0.93 Y Y Perfluorooctanoic acid (PFOA) Y Y Y Y 0.72 J 0.54 Y Perfluorotetradecanoic acid (PFTA) 0.62 J 0.36 Y 0.45 J 0.36 Y 0.43 U 0.43 Y 0.40 U 0.40 Y 0.54 U 0.54 Y Perfluorotridecanoic Acid (PFTriA) 0.72 U 0.72 Y 0.72 U 0.72 Y 0.87 U 0.87 Y 0.80 U 0.80 Y. U. Y Perfluoroundecanoic Acid (PFUnA) Y 0.4 J 0.36 Y 0.43 U 0.43 Y 0.40 U 0.40 Y 0.54 U 0.54 Y Moisture, Percent NA NA NA NA NA Total Organic Carbon Y Y Y Y Y Page of 2
7 SHALLOW SOIL SAMPLE ANALYTICAL TABLE REEDS FERRY ELEMENTARY SCHOOL MERRIMACK, NEW HAMPSHIRE Validated Client Sample ID Lab Sample ID F. Playground 6 to G. SL Memorial Outfield 0 to G. SL Memorial Outfield 6 to H. Playground 0 to H. Playground Duplicate PARAMETER Units Concsoil* Result Q MDL Validated? Result Q MDL Validated? Result Q MDL Validated? Result Q MDL Validated? Result Q MDL Validated? Perfluorobutanesulfonic acid (PFBS) 0.62 U 0.62 Y 0.62 U 0.62 Y 0.58 U 0.58 Y 0.57 U 0.57 Y 0.66 J 0.60 Y Perfluorodecanoic acid (PFDA) 0.25 U 0.25 Y 0.25 U 0.25 Y 0.23 U 0.23 Y 0.23 U 0.23 Y 0.24 U 0.24 Y Perfluorododecanoic acid (PFDoA) 0.50 U 0.50 Y 0.50 U 0.50 Y 0.47 U 0.47 Y 0.45 U 0.45 Y 0.48 U 0.48 Y Perfluoroheptanoic acid (PFHpA) 0.37 U 0.37 Y 0.37 U 0.37 Y 0.35 U 0.35 Y 0.34 U 0.34 Y 0.36 U 0.36 Y Perfluorohexanesulfonic acid (PFHxS) 0.62 U 0.62 Y 0.62 U 0.62 Y 0.58 U 0.58 Y 0.57 U 0.57 Y 0.60 U 0.60 Y Perfluorohexanoic acid (PFHxA) 0.25 U 0.25 Y 0.25 U 0.25 Y 0.23 U 0.23 Y 0.23 U 0.23 Y 0.24 U 0.24 Y Perfluorononanoic acid (PFNA) 0.25 U 0.25 Y 0.25 U 0.25 Y 0.23 U 0.23 Y 0.23 U 0.23 Y 0.24 U 0.24 Y Perfluorooctanesulfonic acid (PFOS) Y 0.87 U 0.87 Y 0.8 U 0.8 Y 0.80 U 0.80 Y 0.84 U 0.84 Y Perfluorooctanoic acid (PFOA) J 0.37 Y Y Y 0.34 U 0.34 Y 0.36 U 0.36 Y Perfluorotetradecanoic acid (PFTA) 0.37 U 0.37 Y 0.37 U 0.37 Y 0.35 U 0.35 Y 0.34 U 0.34 Y 0.78 J 0.36 Y Perfluorotridecanoic Acid (PFTriA) 0.74 U 0.74 Y 0.74 U 0.74 Y 0.70 U 0.70 Y 0.68 U 0.68 Y 0.72 U 0.72 Y Perfluoroundecanoic Acid (PFUnA) 0.37 U 0.37 Y 0.37 U 0.37 Y 0.35 U 0.35 Y 0.34 U 0.34 Y 0.36 U 0.36 Y Moisture, Percent NA NA NA NA NA Total Organic Carbon Y Y Y Y Client Sample ID Lab Sample ID H. Playground 6 to I. Playground 0 to I. Playground 6 to I. Playground 2 to I. Playground 8 to PARAMETER Units Concsoil* Result Q MDL Validated? Result Q MDL Validated? Result Q MDL Validated? Result Q MDL Validated? Result Q MDL Validated? Perfluorobutanesulfonic acid (PFBS) 0.56 U 0.56 Y 0.55 U 0.55 Y 0.57 U 0.57 Y 0.59 U 0.59 Y 0.58 U 0.58 Y Perfluorodecanoic acid (PFDA) 0.23 U 0.23 Y 0.22 U 0.22 Y 0.34 J 0.23 Y 0.23 U 0.23 Y 0.23 U 0.23 Y Perfluorododecanoic acid (PFDoA) 0.45 U 0.45 Y 0.44 U 0.44 Y 0.46 U 0.46 Y 0.47 U 0.47 Y 0.46 U 0.46 Y Perfluoroheptanoic acid (PFHpA) 0.34 U 0.34 Y 0.33 U 0.33 Y 0.34 U 0.34 Y 0.35 U 0.35 Y 0.35 U 0.35 Y Perfluorohexanesulfonic acid (PFHxS) 0.56 U 0.56 Y 0.55 U 0.55 Y 0.57 U 0.57 Y 0.59 U 0.59 Y 0.58 U 0.58 Y Perfluorohexanoic acid (PFHxA) 0.23 U 0.23 Y 0.22 U 0.22 Y 0.23 U 0.23 Y 0.23 U 0.23 Y 0.23 U 0.23 Y Perfluorononanoic acid (PFNA) 0.23 U 0.23 Y 0.22 U 0.22 Y 0.33 J 0.23 Y 0.23 U 0.23 Y 0.23 U 0.23 Y Perfluorooctanesulfonic acid (PFOS) U 0.79 Y 0.77 U 0.77 Y.5 J 0.80 Y 0.82 U 0.82 Y 0.8 U 0.8 Y Perfluorooctanoic acid (PFOA) U 0.34 Y 0.33 U 0.33 Y 0.34 U 0.34 Y Y Y Perfluorotetradecanoic acid (PFTA) 0.34 U 0.34 Y 0.33 U 0.33 Y 0.34 U 0.34 Y 0.35 U 0.35 Y 0.35 U 0.35 Y Perfluorotridecanoic Acid (PFTriA) 0.68 U 0.68 Y 0.66 U 0.66 Y 0.69 U 0.69 Y 0.70 U 0.70 Y 0.69 U 0.69 Y Perfluoroundecanoic Acid (PFUnA) 0.34 U 0.34 Y 0.33 U 0.33 Y 0.34 U 0.34 Y 0.35 U 0.35 Y 0.35 U 0.35 Y Moisture, Percent NA NA NA NA NA Total Organic Carbon 0 3 Y Y Y Y Y Samples analyzed for PFCs by EPA Method 537, rev... * NH Direct Contact Risk Based concentration in soil (Consoil) Screening Value from NHDES Memorandums dated June 7, 6 and June 28, 6 Concentrations denoted in or parts per billion (ppb) U denotes that the parameter was not detected at the value indicated J denotes an estimated value NA denotes Not Applicable Page 2 of 2
8 REVISED ANALYTICAL RESULTS Prepared by: Eurofins Lancaster Laboratories Environmental 2425 New Holland Pike Lancaster, PA 760 Prepared for: C. T. Male Associates 50 Century Hill Drive Latham NY Report Date: September 22, 6 Project: SGPP - Merrimack Submittal Date: 04/30/6 Group Number: SDG: SGP45 PO Number: State of Sample Origin: NH Lancaster Labs Client Sample Description (LL) # I. Playground 0"to6" Grab Soil I. Playground 6"to2" Grab Soil I. Playground 2"to8" Grab Soil I. Playground 8"to24" Grab Soil Auger Rinse #4 Grab Blank Water Bowl Rinse #4 Grab Blank Water Transport Blank #83732 Water The specific methodologies used in obtaining the enclosed analytical results are indicated on the Laboratory Sample Analysis Record. Regulatory agencies do not accredit laboratories for all methods, analytes, and matrices. Our current scopes of accreditation can be viewed at To request copies of prior scopes of accreditation, contact your project manager. Electronic Copy To C. T. Male Associates Attn: Dan Reilly Electronic Copy To C. T. Male Associates Attn: Kirk Moline Page of 8
9 Respectfully Submitted, REVISED (77) Page 2 of 8
10 Case Narrative Project Name: SGPP - Merrimack LL Group #: General Comments: See the Laboratory Sample Analysis Record section of the Analysis Report for the method references. All QC met criteria unless otherwise noted in an Analysis Specific Comment below. Refer to the QC Summary for specific values and acceptance criteria. Project specific QC samples are not included in this data set Matrix QC may not be reported if site-specific QC samples were not submitted. In these situations, to demonstrate precision and accuracy at a batch level, a LCS/LCSD was performed, unless otherwise specified in the method. Surrogate recoveries (if applicable) which are outside of the QC window are confirmed unless attributed to a dilution or otherwise noted in an Analysis Specific Comment below. The samples were received at the appropriate temperature and in accordance with the chain of custody unless otherwise noted. Analysis Specific Comments: EPA 537 Rev.., Misc. Organics Sample #s: , , , , The stated QC limits are advisory only until sufficient data points can be obtained to calculate statistical limits. Batch #: (Sample number(s): UNSPK: MS) The recovery(ies) for the following analyte(s) in the LCS and/or LCSD were below the acceptance window: Perfluoroheptanoic acid, Perfluorohexanesulfonate The recovery(ies) for the following analyte(s) in the MS was outside the acceptance window: Perfluorotridecanoic acid, Perfluorotetradecanoic acid, Perfluorobutanesulfonate Batch #: (Sample number(s): UNSPK: MS) The recovery(ies) for the following analyte(s) in the LCS exceeded the acceptance window indicating a positive bias: Perfluorotetradecanoic acid The recovery(ies) for the following analyte(s) in the LCS were below the acceptance window: Perfluorooctanoic acid SM 530 B -00, Wet Chemistry Batch #: A (Sample number(s): UNSPK: P BKG: P359075) The duplicate RPD for the following analyte(s) exceeded the acceptance window: TOC Solids/Sludges Combustion v.9.4 9/22/6 0:0:09AM Page 3 of 8
11 REVISED Sample Description: I. Playground 0"to6" Grab Soil Reeds Ferry Elementary School Project Name: SGPP - Merrimack Collected: 04/29/6 0:38 Submitted: 04/30/6 0:30 Reported: 09/22/6 0:0 by LC C. T. Male Associates 50 Century Hill Drive Latham NY LL Sample # SW LL Group # Account # 379 IPG- CAT No. SDG#: SGP45-0 CAS Number Result Method Detection Limit* Limit of Quantitation Misc. Organics EPA 537 Rev Perfluorobutanesulfonate U Perfluorodecanoic acid U Perfluorododecanoic acid U Perfluoroheptanoic acid U Perfluorohexanesulfonate U Perfluorohexanoic acid U Perfluorononanoic acid U Perfluoro-octanesulfonate U Perfluorooctanoic acid U Perfluorotetradecanoic acid U Perfluorotridecanoic acid U Perfluoroundecanoic acid U The stated QC limits are advisory only until sufficient data points can be obtained to calculate statistical limits. Wet Chemistry SM 530 B TOC n.a., Wet Chemistry SM 2540 G Moisture n.a Moisture represents the loss in weight of the sample after oven drying at degrees Celsius. The moisture result reported is on an as-received basis. Dilution Factor Sample Comments All QC is compliant unless otherwise noted. Please refer to the Quality Control Summary for overall QC performance data and associated samples. Laboratory Sample Analysis Record CAT No. Method Trial# Batch# Analysis Date and Time Analyst Dilution Factor 4027 Full List PFC's EPA 537 Rev /5/6 07:35 Marissa C Drexinger 4090 PFC Solid Prep EPA 537 Rev //6 5:00 Jason W Knight 079 TOC SM 530 B A 05/08/6 23:59 James S Mathiot Moisture SM 2540 G B 05/05/6 3:45 Larry E Bevins *=This limit was used in the evaluation of the final result Page 4 of 8
12 REVISED Sample Description: I. Playground 6"to2" Grab Soil Reeds Ferry Elementary School Project Name: SGPP - Merrimack Collected: 04/29/6 0:46 Submitted: 04/30/6 0:30 Reported: 09/22/6 0:0 by LC C. T. Male Associates 50 Century Hill Drive Latham NY LL Sample # SW LL Group # Account # 379 IPG-2 CAT No. SDG#: SGP45-02 CAS Number Result Method Detection Limit* Limit of Quantitation Misc. Organics EPA 537 Rev Perfluorobutanesulfonate U Perfluorodecanoic acid J Perfluorododecanoic acid U Perfluoroheptanoic acid U Perfluorohexanesulfonate U Perfluorohexanoic acid U Perfluorononanoic acid J Perfluoro-octanesulfonate J Perfluorooctanoic acid U Perfluorotetradecanoic acid U Perfluorotridecanoic acid U Perfluoroundecanoic acid U The stated QC limits are advisory only until sufficient data points can be obtained to calculate statistical limits. Wet Chemistry SM 530 B TOC n.a. 5,760 43,240 Wet Chemistry SM 2540 G Moisture n.a Moisture represents the loss in weight of the sample after oven drying at degrees Celsius. The moisture result reported is on an as-received basis. Dilution Factor Sample Comments All QC is compliant unless otherwise noted. Please refer to the Quality Control Summary for overall QC performance data and associated samples. Laboratory Sample Analysis Record CAT No. Method Trial# Batch# Analysis Date and Time Analyst Dilution Factor 4027 Full List PFC's EPA 537 Rev /5/6 07:54 Marissa C Drexinger 4090 PFC Solid Prep EPA 537 Rev //6 5:00 Jason W Knight 079 TOC SM 530 B A 05/09/6 00: James S Mathiot Moisture SM 2540 G B 05/05/6 3:45 Larry E Bevins *=This limit was used in the evaluation of the final result Page 5 of 8
13 REVISED Sample Description: I. Playground 2"to8" Grab Soil Reeds Ferry Elementary School Project Name: SGPP - Merrimack Collected: 04/29/6 0:5 Submitted: 04/30/6 0:30 Reported: 09/22/6 0:0 by LC C. T. Male Associates 50 Century Hill Drive Latham NY LL Sample # SW LL Group # Account # 379 IPG-3 CAT No. SDG#: SGP45-03 CAS Number Result Method Detection Limit* Limit of Quantitation Misc. Organics EPA 537 Rev Perfluorobutanesulfonate U Perfluorodecanoic acid U Perfluorododecanoic acid U Perfluoroheptanoic acid U Perfluorohexanesulfonate U Perfluorohexanoic acid U Perfluorononanoic acid U Perfluoro-octanesulfonate U Perfluorooctanoic acid Perfluorotetradecanoic acid U Perfluorotridecanoic acid U Perfluoroundecanoic acid U The stated QC limits are advisory only until sufficient data points can be obtained to calculate statistical limits. Wet Chemistry SM 530 B TOC n.a. 8,930 5,530 Wet Chemistry SM 2540 G Moisture n.a Moisture represents the loss in weight of the sample after oven drying at degrees Celsius. The moisture result reported is on an as-received basis. Dilution Factor Sample Comments All QC is compliant unless otherwise noted. Please refer to the Quality Control Summary for overall QC performance data and associated samples. Laboratory Sample Analysis Record CAT No. Method Trial# Batch# Analysis Date and Time Analyst Dilution Factor 4027 Full List PFC's EPA 537 Rev /5/6 08:3 Marissa C Drexinger 4090 PFC Solid Prep EPA 537 Rev //6 5:00 Jason W Knight 079 TOC SM 530 B A 05/09/6 00:23 James S Mathiot Moisture SM 2540 G B 05/05/6 3:45 Larry E Bevins *=This limit was used in the evaluation of the final result Page 6 of 8
14 REVISED Sample Description: I. Playground 8"to24" Grab Soil Reeds Ferry Elementary School Project Name: SGPP - Merrimack Collected: 04/29/6 0:56 Submitted: 04/30/6 0:30 Reported: 09/22/6 0:0 by LC C. T. Male Associates 50 Century Hill Drive Latham NY LL Sample # SW LL Group # Account # 379 IPG-4 CAT No. SDG#: SGP45-04 CAS Number Result Method Detection Limit* Limit of Quantitation Misc. Organics EPA 537 Rev Perfluorobutanesulfonate U Perfluorodecanoic acid U Perfluorododecanoic acid U Perfluoroheptanoic acid U Perfluorohexanesulfonate U Perfluorohexanoic acid U Perfluorononanoic acid U Perfluoro-octanesulfonate U Perfluorooctanoic acid Perfluorotetradecanoic acid U Perfluorotridecanoic acid U Perfluoroundecanoic acid U The stated QC limits are advisory only until sufficient data points can be obtained to calculate statistical limits. Wet Chemistry SM 530 B TOC n.a. 7, ,2 Wet Chemistry SM 2540 G Moisture n.a Moisture represents the loss in weight of the sample after oven drying at degrees Celsius. The moisture result reported is on an as-received basis. Dilution Factor Sample Comments All QC is compliant unless otherwise noted. Please refer to the Quality Control Summary for overall QC performance data and associated samples. Laboratory Sample Analysis Record CAT No. Method Trial# Batch# Analysis Date and Time Analyst Dilution Factor 4027 Full List PFC's EPA 537 Rev /5/6 08:32 Marissa C Drexinger 4090 PFC Solid Prep EPA 537 Rev //6 5:00 Jason W Knight 079 TOC SM 530 B A 05/09/6 00:58 James S Mathiot Moisture SM 2540 G B 05/05/6 3:45 Larry E Bevins *=This limit was used in the evaluation of the final result Page 7 of 8
15 REVISED Sample Description: Auger Rinse #4 Grab Blank Water Reeds Ferry Elementary School Project Name: SGPP - Merrimack Collected: 04/29/6 :0 Submitted: 04/30/6 0:30 Reported: 09/22/6 0:0 by LC C. T. Male Associates 50 Century Hill Drive Latham NY LL Sample # WW LL Group # Account # 379 AG-04 SDG#: SGP45-05RB CAT No. CAS Number Result Method Detection Limit* Limit of Quantitation Misc. Organics EPA 537 Rev.. ng/l ng/l ng/l 0954 Perfluorooctanoic acid U Perfluorononanoic acid U Perfluorodecanoic acid U Perfluoroundecanoic acid U Perfluorododecanoic acid U Perfluorotridecanoic acid U Perfluorotetradecanoic acid U Perfluorohexanoic acid U Perfluoroheptanoic acid U Perfluorobutanesulfonate U Perfluorohexanesulfonate U Perfluoro-octanesulfonate U 5 0 Dilution Factor Sample Comments All QC is compliant unless otherwise noted. Please refer to the Quality Control Summary for overall QC performance data and associated samples. CAT No. Method 0954 Full List PFC's EPA 537 Rev.. Laboratory Sample Analysis Record Trial# Batch# Analysis Analyst Dilution Date and Time Factor /3/6 :55 Jason W Knight *=This limit was used in the evaluation of the final result Page 8 of 8
16 REVISED Sample Description: Bowl Rinse #4 Grab Blank Water Reeds Ferry Elementary School Project Name: SGPP - Merrimack Collected: 04/29/6 :4 Submitted: 04/30/6 0:30 Reported: 09/22/6 0:0 by LC C. T. Male Associates 50 Century Hill Drive Latham NY LL Sample # WW LL Group # Account # 379 BR-04 SDG#: SGP45-06RB CAT No. CAS Number Result Method Detection Limit* Limit of Quantitation Misc. Organics EPA 537 Rev.. ng/l ng/l ng/l 0954 Perfluorooctanoic acid U Perfluorononanoic acid U Perfluorodecanoic acid U Perfluoroundecanoic acid U Perfluorododecanoic acid U Perfluorotridecanoic acid U Perfluorotetradecanoic acid U Perfluorohexanoic acid U Perfluoroheptanoic acid U Perfluorobutanesulfonate U Perfluorohexanesulfonate U Perfluoro-octanesulfonate U 5 0 Dilution Factor Sample Comments All QC is compliant unless otherwise noted. Please refer to the Quality Control Summary for overall QC performance data and associated samples. CAT No. Method 0954 Full List PFC's EPA 537 Rev.. Laboratory Sample Analysis Record Trial# Batch# Analysis Analyst Dilution Date and Time Factor /3/6 2:3 Jason W Knight *=This limit was used in the evaluation of the final result Page 9 of 8
17 REVISED Sample Description: Transport Blank #83732 Water Reeds Ferry Elementary School Project Name: SGPP - Merrimack Collected: 04/22/6 Submitted: 04/30/6 0:30 Reported: 09/22/6 0:0 C. T. Male Associates 50 Century Hill Drive Latham NY LL Sample # WW LL Group # Account # 379 TB32 SDG#: SGP45-07TB CAT No. CAS Number Result Method Detection Limit* Limit of Quantitation Misc. Organics EPA 537 Rev.. ng/l ng/l ng/l 0954 Perfluorooctanoic acid U Perfluorononanoic acid U Perfluorodecanoic acid U Perfluoroundecanoic acid U Perfluorododecanoic acid U Perfluorotridecanoic acid U Perfluorotetradecanoic acid U Perfluorohexanoic acid U Perfluoroheptanoic acid U Perfluorobutanesulfonate U Perfluorohexanesulfonate U Perfluoro-octanesulfonate U 5 0 The stated QC limits are advisory only until sufficient data points can be obtained to calculate statistical limits. Sample Comments All QC is compliant unless otherwise noted. Please refer to the Quality Control Summary for overall QC performance data and associated samples. Dilution Factor CAT No. Method 0954 Full List PFC's EPA 537 Rev.. Laboratory Sample Analysis Record Trial# Batch# Analysis Analyst Dilution Date and Time Factor /04/6 5:49 Jason W Knight *=This limit was used in the evaluation of the final result Page 0 of 8
18 REVISED Quality Control Summary Client Name: C. T. Male Associates Reported: 09/22/6 0:0 Group Number: Matrix QC may not be reported if insufficient sample or site-specific QC samples were not submitted. In these situations, to demonstrate precision and accuracy at a batch level, a LCS/LCSD was performed, unless otherwise specified in the method. All Inorganic Initial Calibration and Continuing Calibration Blanks met acceptable method criteria unless otherwise noted on the Analysis Report. Method Blank Result MDL** LOQ Batch number: Sample number(s): Perfluorobutanesulfonate 0.50 U Perfluorodecanoic acid 0. U Perfluorododecanoic acid 0.40 U Perfluoroheptanoic acid 0.30 U Perfluorohexanesulfonate 0.50 U Perfluorohexanoic acid 0. U Perfluorononanoic acid 0. U Perfluoro-octanesulfonate 0.70 U Perfluorooctanoic acid 0.30 U Perfluorotetradecanoic acid 0.30 U Perfluorotridecanoic acid 0.60 U Perfluoroundecanoic acid 0.30 U ng/l ng/l ng/l Batch number: Sample number(s): Perfluorooctanoic acid U 2 Perfluorononanoic acid U 2 Perfluorodecanoic acid U 2 Perfluoroundecanoic acid 2 U 2 4 Perfluorododecanoic acid 3 U 3 5 Perfluorotridecanoic acid 2 U 2 4 Perfluorotetradecanoic acid 3 U 3 5 Perfluorohexanoic acid U 2 Perfluoroheptanoic acid U 2 Perfluorobutanesulfonate 4 U 4 0 Perfluorohexanesulfonate 4 U 4 0 Perfluoro-octanesulfonate 5 U 5 0 Batch number: Sample number(s): Perfluorooctanoic acid J 2 Perfluorononanoic acid U 2 Perfluorodecanoic acid U 2 Perfluoroundecanoic acid 2 U 2 4 Perfluorododecanoic acid 3 U 3 5 Perfluorotridecanoic acid 2 U 2 4 Perfluorotetradecanoic acid 3 U 3 5 Perfluorohexanoic acid U 2 Perfluoroheptanoic acid U 2 Perfluorobutanesulfonate 4 U 4 0 Perfluorohexanesulfonate 4 U 4 0 Perfluoro-octanesulfonate 5 U 5 0 *- Outside of specification **-This limit was used in the evaluation of the final result for the blank () The result for one or both determinations was less than five times the LOQ. (2) The unspiked result was more than four times the spike added. P###### is indicative of a Background or Unspiked sample that is batch matrix QC and was not performed using a sample from this submission group. Page of 8
19 REVISED Quality Control Summary Client Name: C. T. Male Associates Reported: 09/22/6 0:0 Group Number: Method Blank (continued) Result MDL** LOQ Batch number: A Sample number(s): TOC 00 U LCS/LCSD LCS Spike LCS LCSD Spike LCSD Added Conc Added Conc LCS REC LCSD REC LCS/LCSD Limits RPD RPD Max Batch number: Sample number(s): Perfluorobutanesulfonate Perfluorodecanoic acid 8.2 Perfluorododecanoic acid 7. Perfluoroheptanoic acid 6.6 Perfluorohexanesulfonate Perfluorohexanoic acid 9 Perfluorononanoic acid 6.7 Perfluoro-octanesulfonate Perfluorooctanoic acid 3.7 Perfluorotetradecanoic acid 30. Perfluorotridecanoic acid 26 Perfluoroundecanoic acid * 5* ng/l ng/l ng/l ng/l Batch number: Sample number(s): Perfluorooctanoic acid Perfluorononanoic acid Perfluorodecanoic acid Perfluoroundecanoic acid Perfluorododecanoic acid Perfluorotridecanoic acid Perfluorotetradecanoic acid Perfluorohexanoic acid Perfluoroheptanoic acid Perfluorobutanesulfonate Perfluorohexanesulfonate Perfluoro-octanesulfonate * * Batch number: Sample number(s): Perfluorooctanoic acid Perfluorononanoic acid Perfluorodecanoic acid Perfluoroundecanoic acid Perfluorododecanoic acid Perfluorotridecanoic acid Perfluorotetradecanoic acid Perfluorohexanoic acid Perfluoroheptanoic acid Perfluorobutanesulfonate *- Outside of specification **-This limit was used in the evaluation of the final result for the blank () The result for one or both determinations was less than five times the LOQ. (2) The unspiked result was more than four times the spike added. P###### is indicative of a Background or Unspiked sample that is batch matrix QC and was not performed using a sample from this submission group. Page 2 of 8
20 REVISED Quality Control Summary Client Name: C. T. Male Associates Reported: 09/22/6 0:0 Group Number: LCS/LCSD (continued) LCS Spike LCS LCSD Spike LCSD Added Conc Added Conc ng/l ng/l ng/l ng/l LCS REC LCSD REC LCS/LCSD Limits RPD RPD Max Perfluorohexanesulfonate Perfluoro-octanesulfonate Batch number: A Sample number(s): TOC Batch number: B Sample number(s): Moisture MS/MSD Unspiked (UNSPK) = the sample used in conjunction with the matrix spike Unspiked Conc MS Spike Added MS Conc MSD Spike Added MSD Conc MS Rec MSD Rec MS/MSD Limits RPD RPD Max Batch number: Sample number(s): UNSPK: Perfluorobutanesulfonate 0.50 U Perfluorodecanoic acid 0. U Perfluorododecanoic acid 0.40 U Perfluoroheptanoic acid 0.30 U Perfluorohexanesulfonate 0.50 U Perfluorohexanoic acid 0. U Perfluorononanoic acid 0. U Perfluoro-octanesulfonate 0.70 U Perfluorooctanoic acid 0.30 U Perfluorotetradecanoic acid 0.30 U Perfluorotridecanoic acid 0.60 U Perfluoroundecanoic acid 0.30 U ng/l ng/l ng/l ng/l ng/l Batch number: Sample number(s): UNSPK: Perfluorooctanoic acid Perfluorononanoic acid U Perfluorodecanoic acid U Perfluoroundecanoic acid 2 U Perfluorododecanoic acid 3 U Perfluorotridecanoic acid 2 U * Perfluorotetradecanoic acid 3 U * Perfluorohexanoic acid U Perfluoroheptanoic acid U Perfluorobutanesulfonate 4 U * Perfluorohexanesulfonate 4 U Perfluoro-octanesulfonate *- Outside of specification **-This limit was used in the evaluation of the final result for the blank () The result for one or both determinations was less than five times the LOQ. (2) The unspiked result was more than four times the spike added. P###### is indicative of a Background or Unspiked sample that is batch matrix QC and was not performed using a sample from this submission group. Page 3 of 8
21 REVISED Quality Control Summary Client Name: C. T. Male Associates Reported: 09/22/6 0:0 Group Number: MS/MSD (continued) Unspiked (UNSPK) = the sample used in conjunction with the matrix spike Unspiked MS Spike MS MSD Spike MSD Conc Added Conc Added Conc ng/l ng/l ng/l ng/l ng/l MS Rec MSD Rec MS/MSD Limits RPD RPD Max Batch number: Sample number(s): UNSPK: Perfluorooctanoic acid U Perfluorononanoic acid U Perfluorodecanoic acid Perfluoroundecanoic acid 2 U Perfluorododecanoic acid 3 U Perfluorotridecanoic acid 2 U Perfluorotetradecanoic acid 3 U Perfluorohexanoic acid U Perfluoroheptanoic acid U Perfluorobutanesulfonate 4 U Perfluorohexanesulfonate 4 U Perfluoro-octanesulfonate 5 U Batch number: A Sample number(s): UNSPK: P TOC Laboratory Duplicate Background (BKG) = the sample used in conjunction with the duplicate BKG Conc DUP Conc DUP RPD DUP RPD Max Batch number: A Sample number(s): BKG: P TOC * () 7 Batch number: B Sample number(s): BKG: P Moisture *- Outside of specification **-This limit was used in the evaluation of the final result for the blank () The result for one or both determinations was less than five times the LOQ. (2) The unspiked result was more than four times the spike added. P###### is indicative of a Background or Unspiked sample that is batch matrix QC and was not performed using a sample from this submission group. Page 4 of 8
22 Page 5 of 8
23 Page 6 of 8
24 Page 7 of 8
25 Explanation of Symbols and Abbreviations The following defines common symbols and abbreviations used in reporting technical data: RL Reporting Limit BMQL Below Minimum Quantitation Level N.D. none detected MPN Most Probable Number TNTC Too Numerous To Count CP Units cobalt-chloroplatinate units IU International Units NTU nephelometric turbidity units umhos/cm micromhos/cm ng nanogram(s) C degrees Celsius F degrees Fahrenheit meq milliequivalents lb. pound(s) g gram(s) kg kilogram(s) µg microgram(s) mg milligram(s) ml milliliter(s) L liter(s) m3 cubic meter(s) µl microliter(s) pg/l picogram/liter < less than > greater than ppm parts per million - One ppm is equivalent to one milligram per kilogram () or one gram per million grams. For aqueous liquids, ppm is usually taken to be equivalent to milligrams per liter (mg/l), because one liter of water has a weight very close to a kilogram. For gases or vapors, one ppm is equivalent to one microliter per liter of gas. ppb parts per billion weight Results printed under this heading have been adjusted for moisture content. This increases the analyte weight basis concentration to approximate the value present in a similar sample without moisture. All other results are reported on an as-received basis. Laboratory Data Qualifiers: B - Analyte detected in the blank C - Result confirmed by reanalysis E - Concentration exceeds the calibration range J (or G, I, X) - estimated value the Method Detection Limit (MDL or DL) and < the Limit of Quantitation (LOQ or RL) P - Concentration difference between the primary and confirmation column >40. The lower result is reported. U - Analyte was not detected at the value indicated V - Concentration difference between the primary and confirmation column >00. The reporting limit is raised due to this disparity and evident interference Additional Organic and Inorganic CLP qualifiers may be used with Form reports as defined by the CLP methods. Qualifiers specific to Dioxin/Furans and PCB Congeners are detailed on the individual Analysis Report. Analytical test results meet all requirements of the associated regulatory program (i.e., NELAC (TNI), DoD, and ISO 7025) unless otherwise noted under the individual analysis. Measurement uncertainty values, as applicable, are available upon request. Tests results relate only to the sample tested. Clients should be aware that a critical step in a chemical or microbiological analysis is the collection of the sample. Unless the sample analyzed is truly representative of the bulk of material involved, the test results will be meaningless. If you have questions regarding the proper techniques of collecting samples, please contact us. We cannot be held responsible for sample integrity, however, unless sampling has been performed by a member of our staff. This report shall not be reproduced except in full, without the written approval of the laboratory. Times are local to the area of activity. Parameters listed in the 40 CFR Part 36 Table II as analyze immediately are not performed within 5 minutes. WARRANTY AND LIMITS OF LIABILITY - In accepting analytical work, we warrant the accuracy of test results for the sample as submitted. THE FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND IS GIVEN IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. WE DISCLAIM ANY OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING A WARRANTY OF FITNESS FOR PARTICULAR PURPOSE AND WARRANTY OF MERCHANTABILITY. IN NO EVENT SHALL EUROFINS LANCASTER LABORATORIES ENVIRONMENTAL, LLC BE LIABLE FOR INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES INCLUDING, BUT NOT LIMITED TO, DAMAGES FOR LOSS OF PROFIT OR GOODWILL REGARDLESS OF (A) THE NEGLIGENCE (EITHER SOLE OR CONCURRENT) OF EUROFINS LANCASTER LABORATORIES ENVIRONMENTAL AND (B) WHETHER EUROFINS LANCASTER LABORATORIES ENVIRONMENTAL HAS BEEN INFORMED OF THE POSSIBILITY OF SUCH DAMAGES. We accept no legal responsibility for the purposes for which the client uses the test results. No purchase order or other order for work shall be accepted by Eurofins Lancaster Laboratories Environmental which includes any conditions that vary from the Standard Terms and Conditions, and Eurofins Lancaster Laboratories Environmental hereby objects to any conflicting terms contained in any acceptance or order submitted by client Page 8 of 8
26 REVISED ANALYTICAL RESULTS Prepared by: Eurofins Lancaster Laboratories Environmental 2425 New Holland Pike Lancaster, PA 760 Prepared for: C. T. Male Associates 50 Century Hill Drive Latham NY Report Date: October 4, 6 Project: SGPP - Merrimack Submittal Date: 04/30/6 Group Number: SDG: SGP44 PO Number: State of Sample Origin: NH Lancaster Labs Client Sample Description (LL) # H. Playground 0"to6" Grab Soil H. Playground 6"to2" Grab Soil H. Playground 6"to2" MS Grab Soil H. Playground 6"to2" MSD Grab Soil H. Playground Duplicate Grab Soil The specific methodologies used in obtaining the enclosed analytical results are indicated on the Laboratory Sample Analysis Record. Regulatory agencies do not accredit laboratories for all methods, analytes, and matrices. Our current scopes of accreditation can be viewed at To request copies of prior scopes of accreditation, contact your project manager. Electronic Copy To C. T. Male Associates Attn: Dan Reilly Electronic Copy To C. T. Male Associates Attn: Kirk Moline Respectfully Submitted, (77) Page of 5
27 Case Narrative Project Name: SGPP - Merrimack LL Group #: General Comments: See the Laboratory Sample Analysis Record section of the Analysis Report for the method references. All QC met criteria unless otherwise noted in an Analysis Specific Comment below. Refer to the QC Summary for specific values and acceptance criteria. Project specific QC samples are included in this data set Matrix QC may not be reported if site-specific QC samples were not submitted. In these situations, to demonstrate precision and accuracy at a batch level, a LCS/LCSD was performed, unless otherwise specified in the method. Surrogate recoveries (if applicable) which are outside of the QC window are confirmed unless attributed to a dilution or otherwise noted in an Analysis Specific Comment below. The samples were received at the appropriate temperature and in accordance with the chain of custody unless otherwise noted. Analysis Specific Comments: EPA 537 Rev.., Misc. Organics Sample #s: , , , , The recovery for a target analyte(s) in the Laboratory Control Spike(s) is outside the QC acceptance limits as noted on the QC Summary. Since the recovery is high and the target analyte(s) was not detected in the sample, the data is reported. Batch #: (Sample number(s): UNSPK: MS) The recovery(ies) for the following analyte(s) in the LCS exceeded the acceptance window indicating a positive bias: Perfluorobutanesulfonate The recovery(ies) for the following analyte(s) in the MS and/or MSD was outside the acceptance window: Perfluorotetradecanoic acid, Perfluorobutanesulfonate, Perfluorohexanoic acid The relative percent difference(s) for the following analyte(s) in the MS/MSD were outside outside acceptance windows: Perfluoro-octanesulfonate SM 530 B -00, Wet Chemistry Batch #: A (Sample number(s): UNSPK: BKG: ) The duplicate RPD for the following analyte(s) exceeded the acceptance window: TOC Solids/Sludges Combustion v.9.4 0/4/6 9:6:28AM Page 2 of 5
28 REVISED Sample Description: H. Playground 0"to6" Grab Soil Reeds Ferry Elementary School Project Name: SGPP - Merrimack Collected: 04/29/6 0:7 through 04/29/6 0:8 Submitted: 04/30/6 0:30 Reported: 0/4/6 09:7 by LC C. T. Male Associates 50 Century Hill Drive Latham NY LL Sample # SW LL Group # Account # 379 HPG- CAT No. SDG#: SGP44-0 CAS Number Result Method Detection Limit* Limit of Quantitation Misc. Organics EPA 537 Rev Perfluorobutanesulfonate U Perfluorodecanoic acid U Perfluorododecanoic acid U Perfluoroheptanoic acid U Perfluorohexanesulfonate U Perfluorohexanoic acid U Perfluorononanoic acid U Perfluoro-octanesulfonate U Perfluorooctanoic acid U Perfluorotetradecanoic acid U Perfluorotridecanoic acid U Perfluoroundecanoic acid U The recovery for a target analyte(s) in the Laboratory Control Spike(s) is outside the QC acceptance limits as noted on the QC Summary. Since the recovery is high and the target analyte(s) was not detected in the sample, the data is reported. Wet Chemistry SM 530 B TOC n.a. 3, Wet Chemistry SM 2540 G Moisture n.a Moisture represents the loss in weight of the sample after oven drying at degrees Celsius. The moisture result reported is on an as-received basis. Dilution Factor Sample Comments All QC is compliant unless otherwise noted. Please refer to the Quality Control Summary for overall QC performance data and associated samples. Laboratory Sample Analysis Record CAT No. Method Trial# Batch# Analysis Date and Time Analyst Dilution Factor 4027 Full List PFC's EPA 537 Rev /06/6 7:9 Jason W Knight 4090 PFC Solid Prep EPA 537 Rev //6 :00 Jason W Knight 079 TOC SM 530 B A 05/08/6 23:05 James S Mathiot Moisture SM 2540 G B 05/05/6 3:45 Larry E Bevins *=This limit was used in the evaluation of the final result Page 3 of 5
29 REVISED Sample Description: H. Playground 6"to2" Grab Soil Reeds Ferry Elementary School Project Name: SGPP - Merrimack Collected: 04/29/6 0: through 04/29/6 0:24 Submitted: 04/30/6 0:30 Reported: 0/4/6 09:7 by LC C. T. Male Associates 50 Century Hill Drive Latham NY LL Sample # SW LL Group # Account # 379 HPG-2 CAT No. SDG#: SGP44-02BKG CAS Number Result Method Detection Limit* Limit of Quantitation Misc. Organics EPA 537 Rev Perfluorobutanesulfonate U Perfluorodecanoic acid U Perfluorododecanoic acid U Perfluoroheptanoic acid U Perfluorohexanesulfonate U Perfluorohexanoic acid U Perfluorononanoic acid U Perfluoro-octanesulfonate U Perfluorooctanoic acid U Perfluorotetradecanoic acid U Perfluorotridecanoic acid U Perfluoroundecanoic acid U The recovery for a target analyte(s) in the Laboratory Control Spike(s) is outside the QC acceptance limits as noted on the QC Summary. Since the recovery is high and the target analyte(s) was not detected in the sample, the data is reported. Wet Chemistry SM 530 B TOC n.a., Wet Chemistry SM 2540 G Moisture n.a Moisture represents the loss in weight of the sample after oven drying at degrees Celsius. The moisture result reported is on an as-received basis. Dilution Factor Sample Comments All QC is compliant unless otherwise noted. Please refer to the Quality Control Summary for overall QC performance data and associated samples. Laboratory Sample Analysis Record CAT No. Method Trial# Batch# Analysis Date and Time Analyst Dilution Factor 4027 Full List PFC's EPA 537 Rev /06/6 7:37 Jason W Knight 4090 PFC Solid Prep EPA 537 Rev //6 :00 Jason W Knight 079 TOC SM 530 B A 05/08/6 23:50 James S Mathiot Moisture SM 2540 G B 05/05/6 3:45 Larry E Bevins *=This limit was used in the evaluation of the final result Page 4 of 5
30 Sample Description: H. Playground 6"to2" MS Grab Soil Reeds Ferry Elementary School Project Name: SGPP - Merrimack Collected: 04/29/6 0: Submitted: 04/30/6 0:30 Reported: 0/4/6 09:7 HPG-2 CAT No. SDG#: SGP44-02MS by LC CAS Number Result C. T. Male Associates 50 Century Hill Drive Latham NY Method Detection Limit* REVISED LL Sample # SW LL Group # Account # 379 Limit of Quantitation Misc. Organics EPA 537 Rev Perfluorobutanesulfonate Perfluorodecanoic acid Perfluorododecanoic acid Perfluoroheptanoic acid Perfluorohexanesulfonate Perfluorohexanoic acid Perfluorononanoic acid Perfluoro-octanesulfonate Perfluorooctanoic acid Perfluorotetradecanoic acid Perfluorotridecanoic acid Perfluoroundecanoic acid The recovery for a target analyte(s) in the Laboratory Control Spike(s) is outside the QC acceptance limits as noted on the QC Summary. Since the recovery is high and the target analyte(s) was not detected in the sample, the data is reported. Wet Chemistry SM 2540 G Moisture n.a Dilution Factor Sample Comments All QC is compliant unless otherwise noted. Please refer to the Quality Control Summary for overall QC performance data and associated samples. Laboratory Sample Analysis Record CAT No. Method Trial# Batch# Analysis Date and Time Analyst Dilution Factor 4027 Full List PFC's EPA 537 Rev /06/6 7:54 Jason W Knight 4090 PFC Solid Prep EPA 537 Rev //6 :00 Jason W Knight 008 Moisture SM 2540 G B 05/05/6 3:45 Larry E Bevins *=This limit was used in the evaluation of the final result Page 5 of 5
31 Sample Description: H. Playground 6"to2" MSD Grab Soil Reeds Ferry Elementary School Project Name: SGPP - Merrimack Collected: 04/29/6 0: Submitted: 04/30/6 0:30 Reported: 0/4/6 09:7 HPG-2 CAT No. SDG#: SGP44-02MSD by LC CAS Number Result C. T. Male Associates 50 Century Hill Drive Latham NY Method Detection Limit* REVISED LL Sample # SW LL Group # Account # 379 Limit of Quantitation Misc. Organics EPA 537 Rev Perfluorobutanesulfonate Perfluorodecanoic acid Perfluorododecanoic acid Perfluoroheptanoic acid Perfluorohexanesulfonate Perfluorohexanoic acid Perfluorononanoic acid Perfluoro-octanesulfonate Perfluorooctanoic acid Perfluorotetradecanoic acid Perfluorotridecanoic acid Perfluoroundecanoic acid The recovery for a target analyte(s) in the Laboratory Control Spike(s) is outside the QC acceptance limits as noted on the QC Summary. Since the recovery is high and the target analyte(s) was not detected in the sample, the data is reported. Wet Chemistry SM 2540 G Moisture n.a Moisture Duplicate n.a The duplicate moisture value is provided to assess the precision of the moisture test. For comparability purposes, the initial moisture determination is the value used to perform dry weight calculations. Dilution Factor Sample Comments All QC is compliant unless otherwise noted. Please refer to the Quality Control Summary for overall QC performance data and associated samples. Laboratory Sample Analysis Record CAT No. Method Trial# Batch# Analysis Date and Time Analyst Dilution Factor 4027 Full List PFC's EPA 537 Rev /06/6 8:2 Jason W Knight 4090 PFC Solid Prep EPA 537 Rev //6 :00 Jason W Knight 008 Moisture SM 2540 G B 05/05/6 3:45 Larry E Bevins 002 Moisture Duplicate SM 2540 G B 05/05/6 3:45 Larry E Bevins *=This limit was used in the evaluation of the final result Page 6 of 5
32 Sample Description: H. Playground Duplicate Grab Soil Reeds Ferry Elementary School Project Name: SGPP - Merrimack Collected: 04/29/6 0:7 Submitted: 04/30/6 0:30 Reported: 0/4/6 09:7 HPGFD CAT No. SDG#: SGP44-03FD by LC CAS Number Result C. T. Male Associates 50 Century Hill Drive Latham NY Method Detection Limit* REVISED LL Sample # SW LL Group # Account # 379 Limit of Quantitation Misc. Organics EPA 537 Rev Perfluorobutanesulfonate J Perfluorodecanoic acid U Perfluorododecanoic acid U Perfluoroheptanoic acid U Perfluorohexanesulfonate U Perfluorohexanoic acid U Perfluorononanoic acid U Perfluoro-octanesulfonate U Perfluorooctanoic acid U Perfluorotetradecanoic acid J Perfluorotridecanoic acid U Perfluoroundecanoic acid U The recovery for a target analyte(s) in the Laboratory Control Spike(s) is outside the QC acceptance limits as noted on the QC Summary. Since the recovery is high and the target analyte(s) was not detected in the sample, the data is reported. Wet Chemistry SM 2540 G Moisture n.a Moisture represents the loss in weight of the sample after oven drying at degrees Celsius. The moisture result reported is on an as-received basis. Dilution Factor Sample Comments All QC is compliant unless otherwise noted. Please refer to the Quality Control Summary for overall QC performance data and associated samples. Laboratory Sample Analysis Record CAT No. Method Trial# Batch# Analysis Date and Time Analyst Dilution Factor 4027 Full List PFC's EPA 537 Rev /06/6 8:48 Jason W Knight 4090 PFC Solid Prep EPA 537 Rev //6 :00 Jason W Knight 00 Moisture SM 2540 G B 05/05/6 3:45 Larry E Bevins *=This limit was used in the evaluation of the final result Page 7 of 5
33 REVISED Quality Control Summary Client Name: C. T. Male Associates Reported: 0/4/6 09:7 Group Number: Matrix QC may not be reported if insufficient sample or site-specific QC samples were not submitted. In these situations, to demonstrate precision and accuracy at a batch level, a LCS/LCSD was performed, unless otherwise specified in the method. All Inorganic Initial Calibration and Continuing Calibration Blanks met acceptable method criteria unless otherwise noted on the Analysis Report. Method Blank Result MDL** LOQ Batch number: Sample number(s): Perfluorobutanesulfonate 0.50 U Perfluorodecanoic acid 0. U Perfluorododecanoic acid 0.40 U Perfluoroheptanoic acid 0.30 U Perfluorohexanesulfonate 0.50 U Perfluorohexanoic acid 0. U Perfluorononanoic acid 0. U Perfluoro-octanesulfonate 0.70 U Perfluorooctanoic acid 0.30 U Perfluorotetradecanoic acid 0.30 U Perfluorotridecanoic acid 0.60 U Perfluoroundecanoic acid 0.30 U Batch number: A Sample number(s): TOC 00 U LCS/LCSD LCS Spike LCS LCSD Spike LCSD Added Conc Added Conc LCS REC LCSD REC LCS/LCSD Limits RPD RPD Max Batch number: Sample number(s): Perfluorobutanesulfonate Perfluorodecanoic acid Perfluorododecanoic acid Perfluoroheptanoic acid 2.04 Perfluorohexanesulfonate Perfluorohexanoic acid 25.3 Perfluorononanoic acid.48 Perfluoro-octanesulfonate Perfluorooctanoic acid 23.6 Perfluorotetradecanoic acid Perfluorotridecanoic acid Perfluoroundecanoic acid * Batch number: A Sample number(s): TOC *- Outside of specification **-This limit was used in the evaluation of the final result for the blank () The result for one or both determinations was less than five times the LOQ. (2) The unspiked result was more than four times the spike added. P###### is indicative of a Background or Unspiked sample that is batch matrix QC and was not performed using a sample from this submission group. Page 8 of 5
34 REVISED Quality Control Summary Client Name: C. T. Male Associates Reported: 0/4/6 09:7 Group Number: LCS/LCSD (continued) LCS Spike LCS LCSD Spike LCSD Added Conc Added Conc LCS REC LCSD REC LCS/LCSD Limits RPD RPD Max Batch number: B Sample number(s): Moisture Moisture Moisture Duplicate MS/MSD Unspiked (UNSPK) = the sample used in conjunction with the matrix spike Unspiked Conc MS Spike Added MS Conc MSD Spike Added MSD Conc MS Rec MSD Rec MS/MSD Limits RPD RPD Max Batch number: Sample number(s): UNSPK: Perfluorobutanesulfonate 0.50 U * 45* Perfluorodecanoic acid 0. U Perfluorododecanoic acid 0.40 U Perfluoroheptanoic acid 0.30 U Perfluorohexanesulfonate 0.50 U Perfluorohexanoic acid 0. U * Perfluorononanoic acid 0. U Perfluoro-octanesulfonate 0.70 U * 30 Perfluorooctanoic acid 0.30 U Perfluorotetradecanoic acid 0.30 U * Perfluorotridecanoic acid 0.60 U Perfluoroundecanoic acid Batch number: A Sample number(s): UNSPK: TOC Laboratory Duplicate Background (BKG) = the sample used in conjunction with the duplicate BKG Conc DUP Conc DUP RPD DUP RPD Max Batch number: A Sample number(s): BKG: TOC * () 7 *- Outside of specification **-This limit was used in the evaluation of the final result for the blank () The result for one or both determinations was less than five times the LOQ. (2) The unspiked result was more than four times the spike added. P###### is indicative of a Background or Unspiked sample that is batch matrix QC and was not performed using a sample from this submission group. Page 9 of 5
35 REVISED Quality Control Summary Client Name: C. T. Male Associates Reported: 0/4/6 09:7 Group Number: Laboratory Duplicate (continued) Background (BKG) = the sample used in conjunction with the duplicate BKG Conc DUP Conc DUP RPD DUP RPD Max Batch number: B Sample number(s): BKG: , P Moisture Moisture Moisture Duplicate *- Outside of specification **-This limit was used in the evaluation of the final result for the blank () The result for one or both determinations was less than five times the LOQ. (2) The unspiked result was more than four times the spike added. P###### is indicative of a Background or Unspiked sample that is batch matrix QC and was not performed using a sample from this submission group. Page 0 of 5
36 Page of 5
37 Page 2 of 5
38 Page 3 of 5
39 Page 4 of 5
40 Explanation of Symbols and Abbreviations The following defines common symbols and abbreviations used in reporting technical data: RL Reporting Limit BMQL Below Minimum Quantitation Level N.D. none detected MPN Most Probable Number TNTC Too Numerous To Count CP Units cobalt-chloroplatinate units IU International Units NTU nephelometric turbidity units umhos/cm micromhos/cm ng nanogram(s) C degrees Celsius F degrees Fahrenheit meq milliequivalents lb. pound(s) g gram(s) kg kilogram(s) µg microgram(s) mg milligram(s) ml milliliter(s) L liter(s) m3 cubic meter(s) µl microliter(s) pg/l picogram/liter < less than > greater than ppm parts per million - One ppm is equivalent to one milligram per kilogram () or one gram per million grams. For aqueous liquids, ppm is usually taken to be equivalent to milligrams per liter (mg/l), because one liter of water has a weight very close to a kilogram. For gases or vapors, one ppm is equivalent to one microliter per liter of gas. ppb parts per billion weight Results printed under this heading have been adjusted for moisture content. This increases the analyte weight basis concentration to approximate the value present in a similar sample without moisture. All other results are reported on an as-received basis. Laboratory Data Qualifiers: B - Analyte detected in the blank C - Result confirmed by reanalysis E - Concentration exceeds the calibration range J (or G, I, X) - estimated value the Method Detection Limit (MDL or DL) and < the Limit of Quantitation (LOQ or RL) P - Concentration difference between the primary and confirmation column >40. The lower result is reported. U - Analyte was not detected at the value indicated V - Concentration difference between the primary and confirmation column >00. The reporting limit is raised due to this disparity and evident interference Additional Organic and Inorganic CLP qualifiers may be used with Form reports as defined by the CLP methods. Qualifiers specific to Dioxin/Furans and PCB Congeners are detailed on the individual Analysis Report. Analytical test results meet all requirements of the associated regulatory program (i.e., NELAC (TNI), DoD, and ISO 7025) unless otherwise noted under the individual analysis. Measurement uncertainty values, as applicable, are available upon request. Tests results relate only to the sample tested. Clients should be aware that a critical step in a chemical or microbiological analysis is the collection of the sample. Unless the sample analyzed is truly representative of the bulk of material involved, the test results will be meaningless. If you have questions regarding the proper techniques of collecting samples, please contact us. We cannot be held responsible for sample integrity, however, unless sampling has been performed by a member of our staff. This report shall not be reproduced except in full, without the written approval of the laboratory. Times are local to the area of activity. Parameters listed in the 40 CFR Part 36 Table II as analyze immediately are not performed within 5 minutes. WARRANTY AND LIMITS OF LIABILITY - In accepting analytical work, we warrant the accuracy of test results for the sample as submitted. THE FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND IS GIVEN IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. WE DISCLAIM ANY OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING A WARRANTY OF FITNESS FOR PARTICULAR PURPOSE AND WARRANTY OF MERCHANTABILITY. IN NO EVENT SHALL EUROFINS LANCASTER LABORATORIES ENVIRONMENTAL, LLC BE LIABLE FOR INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES INCLUDING, BUT NOT LIMITED TO, DAMAGES FOR LOSS OF PROFIT OR GOODWILL REGARDLESS OF (A) THE NEGLIGENCE (EITHER SOLE OR CONCURRENT) OF EUROFINS LANCASTER LABORATORIES ENVIRONMENTAL AND (B) WHETHER EUROFINS LANCASTER LABORATORIES ENVIRONMENTAL HAS BEEN INFORMED OF THE POSSIBILITY OF SUCH DAMAGES. We accept no legal responsibility for the purposes for which the client uses the test results. No purchase order or other order for work shall be accepted by Eurofins Lancaster Laboratories Environmental which includes any conditions that vary from the Standard Terms and Conditions, and Eurofins Lancaster Laboratories Environmental hereby objects to any conflicting terms contained in any acceptance or order submitted by client Page 5 of 5
41 ANALYTICAL RESULTS Prepared by: Eurofins Lancaster Laboratories Environmental 2425 New Holland Pike Lancaster, PA 760 Prepared for: C. T. Male Associates 50 Century Hill Drive Latham NY Report Date: June 2, 6 Project: SGPP - Merrimack Submittal Date: 04/30/6 Group Number: SDG: SGP43 PO Number: State of Sample Origin: NH Lancaster Labs Client Sample Description (LL) # E. Reeds Ferry Nature Trail 0"to6" Grab Soil E. Reeds Ferry Nature Trail 6"to2" Grab Soil The specific methodologies used in obtaining the enclosed analytical results are indicated on the Laboratory Sample Analysis Record. Regulatory agencies do not accredit laboratories for all methods, analytes, and matrices. Our scopes of accreditation can be viewed at Electronic Copy To C. T. Male Associates Attn: Dan Reilly Electronic Copy To C. T. Male Associates Attn: Kirk Moline Respectfully Submitted, (77) Page of
42 Case Narrative Project Name: SGPP - Merrimack LL Group #: General Comments: See the Laboratory Sample Analysis Record section of the Analysis Report for the method references. All QC met criteria unless otherwise noted in an Analysis Specific Comment below. Refer to the QC Summary for specific values and acceptance criteria. Project specific QC samples are not included in this data set Matrix QC may not be reported if site-specific QC samples were not submitted. In these situations, to demonstrate precision and accuracy at a batch level, a LCS/LCSD was performed, unless otherwise specified in the method. Surrogate recoveries (if applicable) which are outside of the QC window are confirmed unless attributed to a dilution or otherwise noted in an Analysis Specific Comment below. The samples were received at the appropriate temperature and in accordance with the chain of custody unless otherwise noted. Analysis Specific Comments: EPA 537 Rev.., Misc. Organics Sample #s: , The stated QC limits are advisory only until sufficient data points can be obtained to calculate statistical limits. Batch #: (Sample number(s): UNSPK: MS) The recovery(ies) for the following analyte(s) in the LCS exceeded the acceptance window indicating a positive bias: Perfluorotetradecanoic acid The recovery(ies) for the following analyte(s) in the LCS were below the acceptance window: Perfluorooctanoic acid SM 530 B -00, Wet Chemistry Batch #: A (Sample number(s): UNSPK: P BKG: P357466) The duplicate RPD for the following analyte(s) exceeded the acceptance window: TOC Solids/Sludges Combustion v.9.4 6/2/6 2:9:2PM Page 2 of
43 Sample Description: E. Reeds Ferry Nature Trail 0"to6" Grab Soil Reeds Ferry Elementary School Project Name: SGPP - Merrimack Collected: 04/29/6 09:5 Submitted: 04/30/6 0:30 Reported: 06/2/6 4: ERF- CAT No. SDG#: SGP43-0 by LC CAS Number Result C. T. Male Associates 50 Century Hill Drive Latham NY Method Detection Limit* LL Sample # SW LL Group # Account # 379 Limit of Quantitation Misc. Organics EPA 537 Rev Perfluorobutanesulfonate U Perfluorodecanoic acid U Perfluorododecanoic acid U Perfluoroheptanoic acid J Perfluorohexanesulfonate U Perfluorohexanoic acid J Perfluorononanoic acid J Perfluoro-octanesulfonate U Perfluorooctanoic acid Perfluorotetradecanoic acid U Perfluorotridecanoic acid U Perfluoroundecanoic acid U The stated QC limits are advisory only until sufficient data points can be obtained to calculate statistical limits. Wet Chemistry SM 530 B TOC n.a. 9,600,00 3,030 Wet Chemistry SM 2540 G Moisture n.a Moisture represents the loss in weight of the sample after oven drying at degrees Celsius. The moisture result reported is on an as-received basis. Dilution Factor Sample Comments All QC is compliant unless otherwise noted. Please refer to the Quality Control Summary for overall QC performance data and associated samples. Laboratory Sample Analysis Record CAT No. Method Trial# Batch# Analysis Date and Time Analyst Dilution Factor 4027 Full List PFC's EPA 537 Rev /5/6 06:56 Marissa C Drexinger 4090 PFC Solid Prep EPA 537 Rev //6 5:00 Jason W Knight 079 TOC SM 530 B A 05/06/6 03:07 James S Mathiot Moisture SM 2540 G B 05/05/6 3:45 Larry E Bevins *=This limit was used in the evaluation of the final result Page 3 of
44 Sample Description: E. Reeds Ferry Nature Trail 6"to2" Grab Soil Reeds Ferry Elementary School Project Name: SGPP - Merrimack Collected: 04/29/6 09: Submitted: 04/30/6 0:30 Reported: 06/2/6 4: ERF-2 CAT No. SDG#: SGP43-02 by LC CAS Number Result C. T. Male Associates 50 Century Hill Drive Latham NY Method Detection Limit* LL Sample # SW LL Group # Account # 379 Limit of Quantitation Misc. Organics EPA 537 Rev Perfluorobutanesulfonate U Perfluorodecanoic acid U Perfluorododecanoic acid U Perfluoroheptanoic acid U Perfluorohexanesulfonate U Perfluorohexanoic acid U Perfluorononanoic acid U Perfluoro-octanesulfonate U Perfluorooctanoic acid Perfluorotetradecanoic acid U Perfluorotridecanoic acid U Perfluoroundecanoic acid U The stated QC limits are advisory only until sufficient data points can be obtained to calculate statistical limits. Wet Chemistry SM 530 B TOC n.a. 5, ,570 Wet Chemistry SM 2540 G Moisture n.a Moisture represents the loss in weight of the sample after oven drying at degrees Celsius. The moisture result reported is on an as-received basis. Dilution Factor Sample Comments All QC is compliant unless otherwise noted. Please refer to the Quality Control Summary for overall QC performance data and associated samples. Laboratory Sample Analysis Record CAT No. Method Trial# Batch# Analysis Date and Time Analyst Dilution Factor 4027 Full List PFC's EPA 537 Rev /5/6 07:5 Marissa C Drexinger 4090 PFC Solid Prep EPA 537 Rev //6 5:00 Jason W Knight 079 TOC SM 530 B A 05/06/6 03:5 James S Mathiot Moisture SM 2540 G B 05/05/6 3:45 Larry E Bevins *=This limit was used in the evaluation of the final result Page 4 of
45 Quality Control Summary Client Name: C. T. Male Associates Reported: 06/2/6 4: Group Number: Matrix QC may not be reported if insufficient sample or site-specific QC samples were not submitted. In these situations, to demonstrate precision and accuracy at a batch level, a LCS/LCSD was performed, unless otherwise specified in the method. All Inorganic Initial Calibration and Continuing Calibration Blanks met acceptable method criteria unless otherwise noted on the Analysis Report. Method Blank Result MDL** LOQ Batch number: Sample number(s): Perfluorobutanesulfonate 0.50 U Perfluorodecanoic acid 0. U Perfluorododecanoic acid 0.40 U Perfluoroheptanoic acid 0.30 U Perfluorohexanesulfonate 0.50 U Perfluorohexanoic acid 0. U Perfluorononanoic acid 0. U Perfluoro-octanesulfonate 0.70 U Perfluorooctanoic acid 0.30 U Perfluorotetradecanoic acid 0.30 U Perfluorotridecanoic acid 0.60 U Perfluoroundecanoic acid 0.30 U Batch number: A Sample number(s): TOC 00 U LCS/LCSD LCS Spike LCS LCSD Spike LCSD Added Conc Added Conc LCS REC LCSD REC LCS/LCSD Limits RPD RPD Max Batch number: Sample number(s): Perfluorobutanesulfonate Perfluorodecanoic acid 8.2 Perfluorododecanoic acid 7. Perfluoroheptanoic acid 6.6 Perfluorohexanesulfonate Perfluorohexanoic acid 9 Perfluorononanoic acid 6.7 Perfluoro-octanesulfonate Perfluorooctanoic acid 3.7 Perfluorotetradecanoic acid 30. Perfluorotridecanoic acid 26 Perfluoroundecanoic acid * 5* Batch number: A Sample number(s): TOC *- Outside of specification **-This limit was used in the evaluation of the final result for the blank () The result for one or both determinations was less than five times the LOQ. (2) The unspiked result was more than four times the spike added. P###### is indicative of a Background or Unspiked sample that is batch matrix QC and was not performed using a sample from this submission group. Page 5 of
46 Quality Control Summary Client Name: C. T. Male Associates Reported: 06/2/6 4: Group Number: LCS/LCSD (continued) LCS Spike LCS LCSD Spike LCSD Added Conc Added Conc LCS REC LCSD REC LCS/LCSD Limits RPD RPD Max Batch number: B Sample number(s): Moisture MS/MSD Unspiked (UNSPK) = the sample used in conjunction with the matrix spike Unspiked Conc MS Spike Added MS Conc MSD Spike Added MSD Conc MS Rec MSD Rec MS/MSD Limits RPD RPD Max Batch number: Sample number(s): UNSPK: Perfluorobutanesulfonate 0.50 U Perfluorodecanoic acid 0. U Perfluorododecanoic acid 0.40 U Perfluoroheptanoic acid 0.30 U Perfluorohexanesulfonate 0.50 U Perfluorohexanoic acid 0. U Perfluorononanoic acid 0. U Perfluoro-octanesulfonate 0.70 U Perfluorooctanoic acid 0.30 U Perfluorotetradecanoic acid 0.30 U Perfluorotridecanoic acid 0.60 U Perfluoroundecanoic acid 0.30 U Batch number: A Sample number(s): UNSPK: P TOC Laboratory Duplicate Background (BKG) = the sample used in conjunction with the duplicate BKG Conc DUP Conc DUP RPD DUP RPD Max Batch number: A Sample number(s): BKG: P TOC * () 7 Batch number: B Sample number(s): BKG: P Moisture *- Outside of specification **-This limit was used in the evaluation of the final result for the blank () The result for one or both determinations was less than five times the LOQ. (2) The unspiked result was more than four times the spike added. P###### is indicative of a Background or Unspiked sample that is batch matrix QC and was not performed using a sample from this submission group. Page 6 of
47 Quality Control Summary Client Name: C. T. Male Associates Reported: 06/2/6 4: Group Number: *- Outside of specification **-This limit was used in the evaluation of the final result for the blank () The result for one or both determinations was less than five times the LOQ. (2) The unspiked result was more than four times the spike added. P###### is indicative of a Background or Unspiked sample that is batch matrix QC and was not performed using a sample from this submission group. Page 7 of
48 Page 8 of
49 Page 9 of
50 Page 0 of
51 Explanation of Symbols and Abbreviations The following defines common symbols and abbreviations used in reporting technical data: RL Reporting Limit BMQL Below Minimum Quantitation Level N.D. none detected MPN Most Probable Number TNTC Too Numerous To Count CP Units cobalt-chloroplatinate units IU International Units NTU nephelometric turbidity units umhos/cm micromhos/cm ng nanogram(s) C degrees Celsius F degrees Fahrenheit meq milliequivalents lb. pound(s) g gram(s) kg kilogram(s) µg microgram(s) mg milligram(s) ml milliliter(s) L liter(s) m3 cubic meter(s) µl microliter(s) pg/l picogram/liter < less than > greater than ppm parts per million - One ppm is equivalent to one milligram per kilogram () or one gram per million grams. For aqueous liquids, ppm is usually taken to be equivalent to milligrams per liter (mg/l), because one liter of water has a weight very close to a kilogram. For gases or vapors, one ppm is equivalent to one microliter per liter of gas. ppb parts per billion weight Results printed under this heading have been adjusted for moisture content. This increases the analyte weight basis concentration to approximate the value present in a similar sample without moisture. All other results are reported on an as-received basis. Laboratory Data Qualifiers: B - Analyte detected in the blank C - Result confirmed by reanalysis E - Concentration exceeds the calibration range J (or G, I, X) - estimated value the Method Detection Limit (MDL or DL) and < the Limit of Quantitation (LOQ or RL) P - Concentration difference between the primary and confirmation column >40. The lower result is reported. U - Analyte was not detected at the value indicated V - Concentration difference between the primary and confirmation column >00. The reporting limit is raised due to this disparity and evident interference Additional Organic and Inorganic CLP qualifiers may be used with Form reports as defined by the CLP methods. Qualifiers specific to Dioxin/Furans and PCB Congeners are detailed on the individual Analysis Report. Analytical test results meet all requirements of the associated regulatory program (i.e., NELAC (TNI), DoD, and ISO 7025) unless otherwise noted under the individual analysis. Measurement uncertainty values, as applicable, are available upon request. Tests results relate only to the sample tested. Clients should be aware that a critical step in a chemical or microbiological analysis is the collection of the sample. Unless the sample analyzed is truly representative of the bulk of material involved, the test results will be meaningless. If you have questions regarding the proper techniques of collecting samples, please contact us. We cannot be held responsible for sample integrity, however, unless sampling has been performed by a member of our staff. This report shall not be reproduced except in full, without the written approval of the laboratory. Times are local to the area of activity. Parameters listed in the 40 CFR Part 36 Table II as analyze immediately are not performed within 5 minutes. WARRANTY AND LIMITS OF LIABILITY - In accepting analytical work, we warrant the accuracy of test results for the sample as submitted. THE FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND IS GIVEN IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. WE DISCLAIM ANY OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING A WARRANTY OF FITNESS FOR PARTICULAR PURPOSE AND WARRANTY OF MERCHANTABILITY. IN NO EVENT SHALL EUROFINS LANCASTER LABORATORIES ENVIRONMENTAL, LLC BE LIABLE FOR INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES INCLUDING, BUT NOT LIMITED TO, DAMAGES FOR LOSS OF PROFIT OR GOODWILL REGARDLESS OF (A) THE NEGLIGENCE (EITHER SOLE OR CONCURRENT) OF EUROFINS LANCASTER LABORATORIES ENVIRONMENTAL AND (B) WHETHER EUROFINS LANCASTER LABORATORIES ENVIRONMENTAL HAS BEEN INFORMED OF THE POSSIBILITY OF SUCH DAMAGES. We accept no legal responsibility for the purposes for which the client uses the test results. No purchase order or other order for work shall be accepted by Eurofins Lancaster Laboratories Environmental which includes any conditions that vary from the Standard Terms and Conditions, and Eurofins Lancaster Laboratories Environmental hereby objects to any conflicting terms contained in any acceptance or order submitted by client Page of
52 ANALYTICAL RESULTS Prepared by: Eurofins Lancaster Laboratories Environmental 2425 New Holland Pike Lancaster, PA 760 Prepared for: C. T. Male Associates 50 Century Hill Drive Latham NY Report Date: June 2, 6 Project: SGPP - Merrimack Submittal Date: 04/30/6 Group Number: SDG: SGP42 PO Number: State of Sample Origin: NH Lancaster Labs Client Sample Description (LL) # F. Playground 0"to6" Grab Soil F. Playground 6"to2" Grab Soil The specific methodologies used in obtaining the enclosed analytical results are indicated on the Laboratory Sample Analysis Record. Regulatory agencies do not accredit laboratories for all methods, analytes, and matrices. Our scopes of accreditation can be viewed at Electronic Copy To C. T. Male Associates Attn: Dan Reilly Electronic Copy To C. T. Male Associates Attn: Kirk Moline Respectfully Submitted, (77) Page of
53 Case Narrative Project Name: SGPP - Merrimack LL Group #: General Comments: See the Laboratory Sample Analysis Record section of the Analysis Report for the method references. All QC met criteria unless otherwise noted in an Analysis Specific Comment below. Refer to the QC Summary for specific values and acceptance criteria. Project specific QC samples are not included in this data set Matrix QC may not be reported if site-specific QC samples were not submitted. In these situations, to demonstrate precision and accuracy at a batch level, a LCS/LCSD was performed, unless otherwise specified in the method. Surrogate recoveries (if applicable) which are outside of the QC window are confirmed unless attributed to a dilution or otherwise noted in an Analysis Specific Comment below. The samples were received at the appropriate temperature and in accordance with the chain of custody unless otherwise noted. Analysis Specific Comments: EPA 537 Rev.., Misc. Organics Sample #s: , The stated QC limits are advisory only until sufficient data points can be obtained to calculate statistical limits. Batch #: (Sample number(s): UNSPK: MS) The recovery(ies) for the following analyte(s) in the LCS exceeded the acceptance window indicating a positive bias: Perfluorotetradecanoic acid The recovery(ies) for the following analyte(s) in the LCS were below the acceptance window: Perfluorooctanoic acid SM 530 B -00, Wet Chemistry Batch #: A (Sample number(s): UNSPK: P BKG: P357466) The duplicate RPD for the following analyte(s) exceeded the acceptance window: TOC Solids/Sludges Combustion SM 2540 G-997, Wet Chemistry Batch #: A (Sample number(s): BKG: P359027) The duplicate RPD for the following analyte(s) exceeded the acceptance window: Moisture v.9.4 6/2/6 2:9:0PM Page 2 of
54 Sample Description: F. Playground 0"to6" Grab Soil Reeds Ferry Elementary School Project Name: SGPP - Merrimack Collected: 04/29/6 08:50 Submitted: 04/30/6 0:30 Reported: 06/2/6 4: by LC C. T. Male Associates 50 Century Hill Drive Latham NY LL Sample # SW LL Group # Account # 379 FPG- CAT No. SDG#: SGP42-0 CAS Number Result Method Detection Limit* Limit of Quantitation Misc. Organics EPA 537 Rev Perfluorobutanesulfonate U Perfluorodecanoic acid U Perfluorododecanoic acid U Perfluoroheptanoic acid U Perfluorohexanesulfonate U Perfluorohexanoic acid J Perfluorononanoic acid J Perfluoro-octanesulfonate Perfluorooctanoic acid J Perfluorotetradecanoic acid U Perfluorotridecanoic acid U Perfluoroundecanoic acid U The stated QC limits are advisory only until sufficient data points can be obtained to calculate statistical limits. Wet Chemistry SM 530 B TOC n.a. 67,800,900 5,70 Wet Chemistry SM 2540 G Moisture n.a Moisture represents the loss in weight of the sample after oven drying at degrees Celsius. The moisture result reported is on an as-received basis. Dilution Factor Sample Comments All QC is compliant unless otherwise noted. Please refer to the Quality Control Summary for overall QC performance data and associated samples. Laboratory Sample Analysis Record CAT No. Method Trial# Batch# Analysis Date and Time Analyst Dilution Factor 4027 Full List PFC's EPA 537 Rev /5/6 06:7 Marissa C Drexinger 4090 PFC Solid Prep EPA 537 Rev //6 5:00 Jason W Knight 079 TOC SM 530 B A 05/06/6 02:47 James S Mathiot Moisture SM 2540 G A 05/05/6 3:45 Larry E Bevins *=This limit was used in the evaluation of the final result Page 3 of
55 Sample Description: F. Playground 6"to2" Grab Soil Reeds Ferry Elementary School Project Name: SGPP - Merrimack Collected: 04/29/6 08:55 Submitted: 04/30/6 0:30 Reported: 06/2/6 4: by LC C. T. Male Associates 50 Century Hill Drive Latham NY LL Sample # SW LL Group # Account # 379 FPG-2 CAT No. SDG#: SGP42-02 CAS Number Result Method Detection Limit* Limit of Quantitation Misc. Organics EPA 537 Rev Perfluorobutanesulfonate U Perfluorodecanoic acid U Perfluorododecanoic acid U Perfluoroheptanoic acid U Perfluorohexanesulfonate U Perfluorohexanoic acid U Perfluorononanoic acid U Perfluoro-octanesulfonate Perfluorooctanoic acid J Perfluorotetradecanoic acid U Perfluorotridecanoic acid U Perfluoroundecanoic acid U The stated QC limits are advisory only until sufficient data points can be obtained to calculate statistical limits. Wet Chemistry SM 530 B TOC n.a. 6, ,0 Wet Chemistry SM 2540 G Moisture n.a Moisture represents the loss in weight of the sample after oven drying at degrees Celsius. The moisture result reported is on an as-received basis. Dilution Factor Sample Comments All QC is compliant unless otherwise noted. Please refer to the Quality Control Summary for overall QC performance data and associated samples. Laboratory Sample Analysis Record CAT No. Method Trial# Batch# Analysis Date and Time Analyst Dilution Factor 4027 Full List PFC's EPA 537 Rev /5/6 06:37 Marissa C Drexinger 4090 PFC Solid Prep EPA 537 Rev //6 5:00 Jason W Knight 079 TOC SM 530 B A 05/06/6 02:59 James S Mathiot Moisture SM 2540 G A 05/05/6 3:45 Larry E Bevins *=This limit was used in the evaluation of the final result Page 4 of
56 Quality Control Summary Client Name: C. T. Male Associates Reported: 06/2/6 4: Group Number: Matrix QC may not be reported if insufficient sample or site-specific QC samples were not submitted. In these situations, to demonstrate precision and accuracy at a batch level, a LCS/LCSD was performed, unless otherwise specified in the method. All Inorganic Initial Calibration and Continuing Calibration Blanks met acceptable method criteria unless otherwise noted on the Analysis Report. Method Blank Result MDL** LOQ Batch number: Sample number(s): Perfluorobutanesulfonate 0.50 U Perfluorodecanoic acid 0. U Perfluorododecanoic acid 0.40 U Perfluoroheptanoic acid 0.30 U Perfluorohexanesulfonate 0.50 U Perfluorohexanoic acid 0. U Perfluorononanoic acid 0. U Perfluoro-octanesulfonate 0.70 U Perfluorooctanoic acid 0.30 U Perfluorotetradecanoic acid 0.30 U Perfluorotridecanoic acid 0.60 U Perfluoroundecanoic acid 0.30 U Batch number: A Sample number(s): TOC 00 U LCS/LCSD LCS Spike LCS LCSD Spike LCSD Added Conc Added Conc LCS REC LCSD REC LCS/LCSD Limits RPD RPD Max Batch number: Sample number(s): Perfluorobutanesulfonate Perfluorodecanoic acid 8.2 Perfluorododecanoic acid 7. Perfluoroheptanoic acid 6.6 Perfluorohexanesulfonate Perfluorohexanoic acid 9 Perfluorononanoic acid 6.7 Perfluoro-octanesulfonate Perfluorooctanoic acid 3.7 Perfluorotetradecanoic acid 30. Perfluorotridecanoic acid 26 Perfluoroundecanoic acid * 5* Batch number: A Sample number(s): TOC *- Outside of specification **-This limit was used in the evaluation of the final result for the blank () The result for one or both determinations was less than five times the LOQ. (2) The unspiked result was more than four times the spike added. P###### is indicative of a Background or Unspiked sample that is batch matrix QC and was not performed using a sample from this submission group. Page 5 of
57 Quality Control Summary Client Name: C. T. Male Associates Reported: 06/2/6 4: Group Number: LCS/LCSD (continued) LCS Spike LCS LCSD Spike LCSD Added Conc Added Conc LCS REC LCSD REC LCS/LCSD Limits RPD RPD Max Batch number: A Sample number(s): Moisture MS/MSD Unspiked (UNSPK) = the sample used in conjunction with the matrix spike Unspiked Conc MS Spike Added MS Conc MSD Spike Added MSD Conc MS Rec MSD Rec MS/MSD Limits RPD RPD Max Batch number: Sample number(s): UNSPK: Perfluorobutanesulfonate 0.50 U Perfluorodecanoic acid 0. U Perfluorododecanoic acid 0.40 U Perfluoroheptanoic acid 0.30 U Perfluorohexanesulfonate 0.50 U Perfluorohexanoic acid 0. U Perfluorononanoic acid 0. U Perfluoro-octanesulfonate 0.70 U Perfluorooctanoic acid 0.30 U Perfluorotetradecanoic acid 0.30 U Perfluorotridecanoic acid 0.60 U Perfluoroundecanoic acid 0.30 U Batch number: A Sample number(s): UNSPK: P TOC Laboratory Duplicate Background (BKG) = the sample used in conjunction with the duplicate BKG Conc DUP Conc DUP RPD DUP RPD Max Batch number: A Sample number(s): BKG: P TOC * () 7 Batch number: A Sample number(s): BKG: P Moisture * 5 *- Outside of specification **-This limit was used in the evaluation of the final result for the blank () The result for one or both determinations was less than five times the LOQ. (2) The unspiked result was more than four times the spike added. P###### is indicative of a Background or Unspiked sample that is batch matrix QC and was not performed using a sample from this submission group. Page 6 of
58 Quality Control Summary Client Name: C. T. Male Associates Reported: 06/2/6 4: Group Number: *- Outside of specification **-This limit was used in the evaluation of the final result for the blank () The result for one or both determinations was less than five times the LOQ. (2) The unspiked result was more than four times the spike added. P###### is indicative of a Background or Unspiked sample that is batch matrix QC and was not performed using a sample from this submission group. Page 7 of
59 Page 8 of
60 Page 9 of
61 Page 0 of
62 Explanation of Symbols and Abbreviations The following defines common symbols and abbreviations used in reporting technical data: RL Reporting Limit BMQL Below Minimum Quantitation Level N.D. none detected MPN Most Probable Number TNTC Too Numerous To Count CP Units cobalt-chloroplatinate units IU International Units NTU nephelometric turbidity units umhos/cm micromhos/cm ng nanogram(s) C degrees Celsius F degrees Fahrenheit meq milliequivalents lb. pound(s) g gram(s) kg kilogram(s) µg microgram(s) mg milligram(s) ml milliliter(s) L liter(s) m3 cubic meter(s) µl microliter(s) pg/l picogram/liter < less than > greater than ppm parts per million - One ppm is equivalent to one milligram per kilogram () or one gram per million grams. For aqueous liquids, ppm is usually taken to be equivalent to milligrams per liter (mg/l), because one liter of water has a weight very close to a kilogram. For gases or vapors, one ppm is equivalent to one microliter per liter of gas. ppb parts per billion weight Results printed under this heading have been adjusted for moisture content. This increases the analyte weight basis concentration to approximate the value present in a similar sample without moisture. All other results are reported on an as-received basis. Laboratory Data Qualifiers: B - Analyte detected in the blank C - Result confirmed by reanalysis E - Concentration exceeds the calibration range J (or G, I, X) - estimated value the Method Detection Limit (MDL or DL) and < the Limit of Quantitation (LOQ or RL) P - Concentration difference between the primary and confirmation column >40. The lower result is reported. U - Analyte was not detected at the value indicated V - Concentration difference between the primary and confirmation column >00. The reporting limit is raised due to this disparity and evident interference Additional Organic and Inorganic CLP qualifiers may be used with Form reports as defined by the CLP methods. Qualifiers specific to Dioxin/Furans and PCB Congeners are detailed on the individual Analysis Report. Analytical test results meet all requirements of the associated regulatory program (i.e., NELAC (TNI), DoD, and ISO 7025) unless otherwise noted under the individual analysis. Measurement uncertainty values, as applicable, are available upon request. Tests results relate only to the sample tested. Clients should be aware that a critical step in a chemical or microbiological analysis is the collection of the sample. Unless the sample analyzed is truly representative of the bulk of material involved, the test results will be meaningless. If you have questions regarding the proper techniques of collecting samples, please contact us. We cannot be held responsible for sample integrity, however, unless sampling has been performed by a member of our staff. This report shall not be reproduced except in full, without the written approval of the laboratory. Times are local to the area of activity. Parameters listed in the 40 CFR Part 36 Table II as analyze immediately are not performed within 5 minutes. WARRANTY AND LIMITS OF LIABILITY - In accepting analytical work, we warrant the accuracy of test results for the sample as submitted. THE FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND IS GIVEN IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. WE DISCLAIM ANY OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING A WARRANTY OF FITNESS FOR PARTICULAR PURPOSE AND WARRANTY OF MERCHANTABILITY. IN NO EVENT SHALL EUROFINS LANCASTER LABORATORIES ENVIRONMENTAL, LLC BE LIABLE FOR INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES INCLUDING, BUT NOT LIMITED TO, DAMAGES FOR LOSS OF PROFIT OR GOODWILL REGARDLESS OF (A) THE NEGLIGENCE (EITHER SOLE OR CONCURRENT) OF EUROFINS LANCASTER LABORATORIES ENVIRONMENTAL AND (B) WHETHER EUROFINS LANCASTER LABORATORIES ENVIRONMENTAL HAS BEEN INFORMED OF THE POSSIBILITY OF SUCH DAMAGES. We accept no legal responsibility for the purposes for which the client uses the test results. No purchase order or other order for work shall be accepted by Eurofins Lancaster Laboratories Environmental which includes any conditions that vary from the Standard Terms and Conditions, and Eurofins Lancaster Laboratories Environmental hereby objects to any conflicting terms contained in any acceptance or order submitted by client Page of
63 ANALYTICAL RESULTS Prepared by: Eurofins Lancaster Laboratories Environmental 2425 New Holland Pike Lancaster, PA 760 Prepared for: C. T. Male Associates 50 Century Hill Drive Latham NY Report Date: June 2, 6 Project: SGPP - Merrimack Submittal Date: 04/30/6 Group Number: SDG: SGP4 PO Number: State of Sample Origin: NH Lancaster Labs Client Sample Description (LL) # G. SL Memorial Outfield 0"to6" Grab Soil G. SL Memorial Outfield 6"to2" Grab Soil The specific methodologies used in obtaining the enclosed analytical results are indicated on the Laboratory Sample Analysis Record. Regulatory agencies do not accredit laboratories for all methods, analytes, and matrices. Our scopes of accreditation can be viewed at Electronic Copy To C. T. Male Associates Attn: Dan Reilly Electronic Copy To C. T. Male Associates Attn: Kirk Moline Respectfully Submitted, (77) Page of
64 Case Narrative Project Name: SGPP - Merrimack LL Group #: General Comments: See the Laboratory Sample Analysis Record section of the Analysis Report for the method references. All QC met criteria unless otherwise noted in an Analysis Specific Comment below. Refer to the QC Summary for specific values and acceptance criteria. Project specific QC samples are not included in this data set Matrix QC may not be reported if site-specific QC samples were not submitted. In these situations, to demonstrate precision and accuracy at a batch level, a LCS/LCSD was performed, unless otherwise specified in the method. Surrogate recoveries (if applicable) which are outside of the QC window are confirmed unless attributed to a dilution or otherwise noted in an Analysis Specific Comment below. The samples were received at the appropriate temperature and in accordance with the chain of custody unless otherwise noted. Analysis Specific Comments: EPA 537 Rev.., Misc. Organics Sample #s: , The stated QC limits are advisory only until sufficient data points can be obtained to calculate statistical limits. Batch #: (Sample number(s): UNSPK: MS) The recovery(ies) for the following analyte(s) in the LCS exceeded the acceptance window indicating a positive bias: Perfluorotetradecanoic acid The recovery(ies) for the following analyte(s) in the LCS were below the acceptance window: Perfluorooctanoic acid SM 530 B -00, Wet Chemistry Batch #: A (Sample number(s): UNSPK: P BKG: P357466) The duplicate RPD for the following analyte(s) exceeded the acceptance window: TOC Solids/Sludges Combustion Batch #: B (Sample number(s): UNSPK: P BKG: P359038) The duplicate RPD for the following analyte(s) exceeded the acceptance window: TOC Solids/Sludges Combustion SM 2540 G-997, Wet Chemistry Batch #: A (Sample number(s): BKG: P359027) The duplicate RPD for the following analyte(s) exceeded the acceptance window: Moisture v.9.4 6/2/6 2:8:53PM Page 2 of
65 Sample Description: G. SL Memorial Outfield 0"to6" Grab Soil Reeds Ferry Elementary School Project Name: SGPP - Merrimack Collected: 04/29/6 08:30 Submitted: 04/30/6 0:30 Reported: 06/2/6 4:9 GSL- CAT No. SDG#: SGP4-0 by LC CAS Number Result C. T. Male Associates 50 Century Hill Drive Latham NY Method Detection Limit* LL Sample # SW LL Group # Account # 379 Limit of Quantitation Misc. Organics EPA 537 Rev Perfluorobutanesulfonate U Perfluorodecanoic acid U Perfluorododecanoic acid U Perfluoroheptanoic acid U Perfluorohexanesulfonate U Perfluorohexanoic acid U Perfluorononanoic acid U Perfluoro-octanesulfonate U Perfluorooctanoic acid Perfluorotetradecanoic acid U Perfluorotridecanoic acid U Perfluoroundecanoic acid U The stated QC limits are advisory only until sufficient data points can be obtained to calculate statistical limits. Wet Chemistry SM 530 B TOC n.a. 8, Wet Chemistry SM 2540 G Moisture n.a Moisture represents the loss in weight of the sample after oven drying at degrees Celsius. The moisture result reported is on an as-received basis. Dilution Factor Sample Comments All QC is compliant unless otherwise noted. Please refer to the Quality Control Summary for overall QC performance data and associated samples. Laboratory Sample Analysis Record CAT No. Method Trial# Batch# Analysis Date and Time Analyst Dilution Factor 4027 Full List PFC's EPA 537 Rev /5/6 05: Marissa C Drexinger 4090 PFC Solid Prep EPA 537 Rev //6 5:00 Jason W Knight 079 TOC SM 530 B B 05/06/6 02:24 James S Mathiot Moisture SM 2540 G A 05/05/6 3:45 Larry E Bevins *=This limit was used in the evaluation of the final result Page 3 of
66 Sample Description: G. SL Memorial Outfield 6"to2" Grab Soil Reeds Ferry Elementary School Project Name: SGPP - Merrimack Collected: 04/29/6 08:35 Submitted: 04/30/6 0:30 Reported: 06/2/6 4:9 GSL-2 CAT No. SDG#: SGP4-02 by LC CAS Number Result C. T. Male Associates 50 Century Hill Drive Latham NY Method Detection Limit* LL Sample # SW LL Group # Account # 379 Limit of Quantitation Misc. Organics EPA 537 Rev Perfluorobutanesulfonate U Perfluorodecanoic acid U Perfluorododecanoic acid U Perfluoroheptanoic acid U Perfluorohexanesulfonate U Perfluorohexanoic acid U Perfluorononanoic acid U Perfluoro-octanesulfonate U Perfluorooctanoic acid Perfluorotetradecanoic acid U Perfluorotridecanoic acid U Perfluoroundecanoic acid U The stated QC limits are advisory only until sufficient data points can be obtained to calculate statistical limits. Wet Chemistry SM 530 B TOC n.a Wet Chemistry SM 2540 G Moisture n.a Moisture represents the loss in weight of the sample after oven drying at degrees Celsius. The moisture result reported is on an as-received basis. Dilution Factor Sample Comments All QC is compliant unless otherwise noted. Please refer to the Quality Control Summary for overall QC performance data and associated samples. Laboratory Sample Analysis Record CAT No. Method Trial# Batch# Analysis Date and Time Analyst Dilution Factor 4027 Full List PFC's EPA 537 Rev /5/6 05:58 Marissa C Drexinger 4090 PFC Solid Prep EPA 537 Rev //6 5:00 Jason W Knight 079 TOC SM 530 B A 05/06/6 02:38 James S Mathiot Moisture SM 2540 G A 05/05/6 3:45 Larry E Bevins *=This limit was used in the evaluation of the final result Page 4 of
67 Quality Control Summary Client Name: C. T. Male Associates Reported: 06/2/6 4:9 Group Number: Matrix QC may not be reported if insufficient sample or site-specific QC samples were not submitted. In these situations, to demonstrate precision and accuracy at a batch level, a LCS/LCSD was performed, unless otherwise specified in the method. All Inorganic Initial Calibration and Continuing Calibration Blanks met acceptable method criteria unless otherwise noted on the Analysis Report. Method Blank Result MDL** LOQ Batch number: Sample number(s): Perfluorobutanesulfonate 0.50 U Perfluorodecanoic acid 0. U Perfluorododecanoic acid 0.40 U Perfluoroheptanoic acid 0.30 U Perfluorohexanesulfonate 0.50 U Perfluorohexanoic acid 0. U Perfluorononanoic acid 0. U Perfluoro-octanesulfonate 0.70 U Perfluorooctanoic acid 0.30 U Perfluorotetradecanoic acid 0.30 U Perfluorotridecanoic acid 0.60 U Perfluoroundecanoic acid 0.30 U Batch number: A Sample number(s): TOC 00 U 00 Batch number: B Sample number(s): TOC 00 U LCS/LCSD LCS Spike LCS LCSD Spike LCSD Added Conc Added Conc LCS REC LCSD REC LCS/LCSD Limits RPD RPD Max Batch number: Sample number(s): Perfluorobutanesulfonate Perfluorodecanoic acid 8.2 Perfluorododecanoic acid 7. Perfluoroheptanoic acid 6.6 Perfluorohexanesulfonate Perfluorohexanoic acid 9 Perfluorononanoic acid 6.7 Perfluoro-octanesulfonate Perfluorooctanoic acid 3.7 Perfluorotetradecanoic acid 30. Perfluorotridecanoic acid 26 Perfluoroundecanoic acid * 5* *- Outside of specification **-This limit was used in the evaluation of the final result for the blank () The result for one or both determinations was less than five times the LOQ. (2) The unspiked result was more than four times the spike added. P###### is indicative of a Background or Unspiked sample that is batch matrix QC and was not performed using a sample from this submission group. Page 5 of
68 Quality Control Summary Client Name: C. T. Male Associates Reported: 06/2/6 4:9 Group Number: LCS/LCSD (continued) LCS Spike LCS LCSD Spike LCSD Added Conc Added Conc LCS REC LCSD REC LCS/LCSD Limits RPD RPD Max Batch number: A Sample number(s): TOC Batch number: B Sample number(s): TOC Batch number: A Sample number(s): Moisture MS/MSD Unspiked (UNSPK) = the sample used in conjunction with the matrix spike Unspiked Conc MS Spike Added MS Conc MSD Spike Added MSD Conc MS Rec MSD Rec MS/MSD Limits RPD RPD Max Batch number: Sample number(s): UNSPK: Perfluorobutanesulfonate 0.50 U Perfluorodecanoic acid 0. U Perfluorododecanoic acid 0.40 U Perfluoroheptanoic acid 0.30 U Perfluorohexanesulfonate 0.50 U Perfluorohexanoic acid 0. U Perfluorononanoic acid 0. U Perfluoro-octanesulfonate 0.70 U Perfluorooctanoic acid 0.30 U Perfluorotetradecanoic acid 0.30 U Perfluorotridecanoic acid 0.60 U Perfluoroundecanoic acid 0.30 U Batch number: A Sample number(s): UNSPK: P TOC Batch number: B Sample number(s): UNSPK: P TOC Laboratory Duplicate Background (BKG) = the sample used in conjunction with the duplicate BKG Conc DUP Conc DUP RPD DUP RPD Max *- Outside of specification **-This limit was used in the evaluation of the final result for the blank () The result for one or both determinations was less than five times the LOQ. (2) The unspiked result was more than four times the spike added. P###### is indicative of a Background or Unspiked sample that is batch matrix QC and was not performed using a sample from this submission group. Page 6 of
69 Quality Control Summary Client Name: C. T. Male Associates Reported: 06/2/6 4:9 Group Number: Laboratory Duplicate Background (BKG) = the sample used in conjunction with the duplicate BKG Conc DUP Conc DUP RPD DUP RPD Max Batch number: A Sample number(s): BKG: P TOC * () 7 Batch number: B Sample number(s): BKG: P TOC * () 7 Batch number: A Sample number(s): BKG: P Moisture * 5 *- Outside of specification **-This limit was used in the evaluation of the final result for the blank () The result for one or both determinations was less than five times the LOQ. (2) The unspiked result was more than four times the spike added. P###### is indicative of a Background or Unspiked sample that is batch matrix QC and was not performed using a sample from this submission group. Page 7 of
70 Page 8 of
71 Page 9 of
72 Page 0 of
73 Explanation of Symbols and Abbreviations The following defines common symbols and abbreviations used in reporting technical data: RL Reporting Limit BMQL Below Minimum Quantitation Level N.D. none detected MPN Most Probable Number TNTC Too Numerous To Count CP Units cobalt-chloroplatinate units IU International Units NTU nephelometric turbidity units umhos/cm micromhos/cm ng nanogram(s) C degrees Celsius F degrees Fahrenheit meq milliequivalents lb. pound(s) g gram(s) kg kilogram(s) µg microgram(s) mg milligram(s) ml milliliter(s) L liter(s) m3 cubic meter(s) µl microliter(s) pg/l picogram/liter < less than > greater than ppm parts per million - One ppm is equivalent to one milligram per kilogram () or one gram per million grams. For aqueous liquids, ppm is usually taken to be equivalent to milligrams per liter (mg/l), because one liter of water has a weight very close to a kilogram. For gases or vapors, one ppm is equivalent to one microliter per liter of gas. ppb parts per billion weight Results printed under this heading have been adjusted for moisture content. This increases the analyte weight basis concentration to approximate the value present in a similar sample without moisture. All other results are reported on an as-received basis. Laboratory Data Qualifiers: B - Analyte detected in the blank C - Result confirmed by reanalysis E - Concentration exceeds the calibration range J (or G, I, X) - estimated value the Method Detection Limit (MDL or DL) and < the Limit of Quantitation (LOQ or RL) P - Concentration difference between the primary and confirmation column >40. The lower result is reported. U - Analyte was not detected at the value indicated V - Concentration difference between the primary and confirmation column >00. The reporting limit is raised due to this disparity and evident interference Additional Organic and Inorganic CLP qualifiers may be used with Form reports as defined by the CLP methods. Qualifiers specific to Dioxin/Furans and PCB Congeners are detailed on the individual Analysis Report. Analytical test results meet all requirements of the associated regulatory program (i.e., NELAC (TNI), DoD, and ISO 7025) unless otherwise noted under the individual analysis. Measurement uncertainty values, as applicable, are available upon request. Tests results relate only to the sample tested. Clients should be aware that a critical step in a chemical or microbiological analysis is the collection of the sample. Unless the sample analyzed is truly representative of the bulk of material involved, the test results will be meaningless. If you have questions regarding the proper techniques of collecting samples, please contact us. We cannot be held responsible for sample integrity, however, unless sampling has been performed by a member of our staff. This report shall not be reproduced except in full, without the written approval of the laboratory. Times are local to the area of activity. Parameters listed in the 40 CFR Part 36 Table II as analyze immediately are not performed within 5 minutes. WARRANTY AND LIMITS OF LIABILITY - In accepting analytical work, we warrant the accuracy of test results for the sample as submitted. THE FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND IS GIVEN IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. WE DISCLAIM ANY OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING A WARRANTY OF FITNESS FOR PARTICULAR PURPOSE AND WARRANTY OF MERCHANTABILITY. IN NO EVENT SHALL EUROFINS LANCASTER LABORATORIES ENVIRONMENTAL, LLC BE LIABLE FOR INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES INCLUDING, BUT NOT LIMITED TO, DAMAGES FOR LOSS OF PROFIT OR GOODWILL REGARDLESS OF (A) THE NEGLIGENCE (EITHER SOLE OR CONCURRENT) OF EUROFINS LANCASTER LABORATORIES ENVIRONMENTAL AND (B) WHETHER EUROFINS LANCASTER LABORATORIES ENVIRONMENTAL HAS BEEN INFORMED OF THE POSSIBILITY OF SUCH DAMAGES. We accept no legal responsibility for the purposes for which the client uses the test results. No purchase order or other order for work shall be accepted by Eurofins Lancaster Laboratories Environmental which includes any conditions that vary from the Standard Terms and Conditions, and Eurofins Lancaster Laboratories Environmental hereby objects to any conflicting terms contained in any acceptance or order submitted by client Page of
74 ANALYTICAL RESULTS Prepared by: Eurofins Lancaster Laboratories Environmental 2425 New Holland Pike Lancaster, PA 760 Prepared for: C. T. Male Associates 50 Century Hill Drive Latham NY Report Date: June 2, 6 Project: SGPP - Merrimack Submittal Date: 04/30/6 Group Number: SDG: SGP40 PO Number: State of Sample Origin: NH Lancaster Labs Client Sample Description (LL) # B. Bball Outfield #2 0"to6" Grab Soil B. Bball Outfield #2 6"to2" Grab Soil The specific methodologies used in obtaining the enclosed analytical results are indicated on the Laboratory Sample Analysis Record. Regulatory agencies do not accredit laboratories for all methods, analytes, and matrices. Our scopes of accreditation can be viewed at Electronic Copy To C. T. Male Associates Attn: Dan Reilly Electronic Copy To C. T. Male Associates Attn: Kirk Moline Respectfully Submitted, (77) Page of
75 Case Narrative Project Name: SGPP - Merrimack LL Group #: General Comments: See the Laboratory Sample Analysis Record section of the Analysis Report for the method references. All QC met criteria unless otherwise noted in an Analysis Specific Comment below. Refer to the QC Summary for specific values and acceptance criteria. Project specific QC samples are not included in this data set Matrix QC may not be reported if site-specific QC samples were not submitted. In these situations, to demonstrate precision and accuracy at a batch level, a LCS/LCSD was performed, unless otherwise specified in the method. Surrogate recoveries (if applicable) which are outside of the QC window are confirmed unless attributed to a dilution or otherwise noted in an Analysis Specific Comment below. The samples were received at the appropriate temperature and in accordance with the chain of custody unless otherwise noted. Analysis Specific Comments: EPA 537 Rev.., Misc. Organics Sample #s: , The stated QC limits are advisory only until sufficient data points can be obtained to calculate statistical limits. Batch #: (Sample number(s): UNSPK: MS) The recovery(ies) for the following analyte(s) in the LCS exceeded the acceptance window indicating a positive bias: Perfluorotetradecanoic acid The recovery(ies) for the following analyte(s) in the LCS were below the acceptance window: Perfluorooctanoic acid SM 530 B -00, Wet Chemistry Batch #: B (Sample number(s): UNSPK: P BKG: P359038) The duplicate RPD for the following analyte(s) exceeded the acceptance window: TOC Solids/Sludges Combustion SM 2540 G-997, Wet Chemistry Batch #: A (Sample number(s): BKG: P359027) The duplicate RPD for the following analyte(s) exceeded the acceptance window: Moisture v.9.4 6/2/6 2:8:43PM Page 2 of
76 Sample Description: B. Bball Outfield #2 0"to6" Grab Soil Reeds Ferry Elementary School Project Name: SGPP - Merrimack Collected: 04/28/6 5:50 Submitted: 04/30/6 0:30 Reported: 06/2/6 4:9 BBB- CAT No. SDG#: SGP40-0 by LC CAS Number Result C. T. Male Associates 50 Century Hill Drive Latham NY Method Detection Limit* LL Sample # SW LL Group # Account # 379 Limit of Quantitation Misc. Organics EPA 537 Rev Perfluorobutanesulfonate U Perfluorodecanoic acid U Perfluorododecanoic acid U Perfluoroheptanoic acid U Perfluorohexanesulfonate U Perfluorohexanoic acid U Perfluorononanoic acid U Perfluoro-octanesulfonate J Perfluorooctanoic acid Perfluorotetradecanoic acid U Perfluorotridecanoic acid U Perfluoroundecanoic acid U The stated QC limits are advisory only until sufficient data points can be obtained to calculate statistical limits. Wet Chemistry SM 530 B TOC n.a. 6, ,060 Wet Chemistry SM 2540 G Moisture n.a Moisture represents the loss in weight of the sample after oven drying at degrees Celsius. The moisture result reported is on an as-received basis. Dilution Factor Sample Comments All QC is compliant unless otherwise noted. Please refer to the Quality Control Summary for overall QC performance data and associated samples. Laboratory Sample Analysis Record CAT No. Method Trial# Batch# Analysis Date and Time Analyst Dilution Factor 4027 Full List PFC's EPA 537 Rev /5/6 04:4 Marissa C Drexinger 4090 PFC Solid Prep EPA 537 Rev //6 5:00 Jason W Knight 079 TOC SM 530 B B 05/06/6 0:43 James S Mathiot Moisture SM 2540 G A 05/05/6 3:45 Larry E Bevins *=This limit was used in the evaluation of the final result Page 3 of
77 Sample Description: B. Bball Outfield #2 6"to2" Grab Soil Reeds Ferry Elementary School Project Name: SGPP - Merrimack Collected: 04/28/6 5:56 Submitted: 04/30/6 0:30 Reported: 06/2/6 4:9 BBB-2 CAT No. SDG#: SGP40-02 by LC CAS Number Result C. T. Male Associates 50 Century Hill Drive Latham NY Method Detection Limit* LL Sample # SW LL Group # Account # 379 Limit of Quantitation Misc. Organics EPA 537 Rev Perfluorobutanesulfonate U Perfluorodecanoic acid U Perfluorododecanoic acid U Perfluoroheptanoic acid U Perfluorohexanesulfonate U Perfluorohexanoic acid U Perfluorononanoic acid U Perfluoro-octanesulfonate U Perfluorooctanoic acid Perfluorotetradecanoic acid U Perfluorotridecanoic acid U Perfluoroundecanoic acid U The stated QC limits are advisory only until sufficient data points can be obtained to calculate statistical limits. Wet Chemistry SM 530 B TOC n.a. 8, , Wet Chemistry SM 2540 G Moisture n.a Moisture represents the loss in weight of the sample after oven drying at degrees Celsius. The moisture result reported is on an as-received basis. Dilution Factor Sample Comments All QC is compliant unless otherwise noted. Please refer to the Quality Control Summary for overall QC performance data and associated samples. Laboratory Sample Analysis Record CAT No. Method Trial# Batch# Analysis Date and Time Analyst Dilution Factor 4027 Full List PFC's EPA 537 Rev /5/6 05:00 Marissa C Drexinger 4090 PFC Solid Prep EPA 537 Rev //6 5:00 Jason W Knight 079 TOC SM 530 B B 05/06/6 02: James S Mathiot Moisture SM 2540 G A 05/05/6 3:45 Larry E Bevins *=This limit was used in the evaluation of the final result Page 4 of
78 Quality Control Summary Client Name: C. T. Male Associates Reported: 06/2/6 4:9 Group Number: Matrix QC may not be reported if insufficient sample or site-specific QC samples were not submitted. In these situations, to demonstrate precision and accuracy at a batch level, a LCS/LCSD was performed, unless otherwise specified in the method. All Inorganic Initial Calibration and Continuing Calibration Blanks met acceptable method criteria unless otherwise noted on the Analysis Report. Method Blank Result MDL** LOQ Batch number: Sample number(s): Perfluorobutanesulfonate 0.50 U Perfluorodecanoic acid 0. U Perfluorododecanoic acid 0.40 U Perfluoroheptanoic acid 0.30 U Perfluorohexanesulfonate 0.50 U Perfluorohexanoic acid 0. U Perfluorononanoic acid 0. U Perfluoro-octanesulfonate 0.70 U Perfluorooctanoic acid 0.30 U Perfluorotetradecanoic acid 0.30 U Perfluorotridecanoic acid 0.60 U Perfluoroundecanoic acid 0.30 U Batch number: B Sample number(s): TOC 00 U LCS/LCSD LCS Spike LCS LCSD Spike LCSD Added Conc Added Conc LCS REC LCSD REC LCS/LCSD Limits RPD RPD Max Batch number: Sample number(s): Perfluorobutanesulfonate Perfluorodecanoic acid 8.2 Perfluorododecanoic acid 7. Perfluoroheptanoic acid 6.6 Perfluorohexanesulfonate Perfluorohexanoic acid 9 Perfluorononanoic acid 6.7 Perfluoro-octanesulfonate Perfluorooctanoic acid 3.7 Perfluorotetradecanoic acid 30. Perfluorotridecanoic acid 26 Perfluoroundecanoic acid * 5* Batch number: B Sample number(s): TOC *- Outside of specification **-This limit was used in the evaluation of the final result for the blank () The result for one or both determinations was less than five times the LOQ. (2) The unspiked result was more than four times the spike added. P###### is indicative of a Background or Unspiked sample that is batch matrix QC and was not performed using a sample from this submission group. Page 5 of
79 Quality Control Summary Client Name: C. T. Male Associates Reported: 06/2/6 4:9 Group Number: LCS/LCSD (continued) LCS Spike LCS LCSD Spike LCSD Added Conc Added Conc LCS REC LCSD REC LCS/LCSD Limits RPD RPD Max Batch number: A Sample number(s): Moisture MS/MSD Unspiked (UNSPK) = the sample used in conjunction with the matrix spike Unspiked Conc MS Spike Added MS Conc MSD Spike Added MSD Conc MS Rec MSD Rec MS/MSD Limits RPD RPD Max Batch number: Sample number(s): UNSPK: Perfluorobutanesulfonate 0.50 U Perfluorodecanoic acid 0. U Perfluorododecanoic acid 0.40 U Perfluoroheptanoic acid 0.30 U Perfluorohexanesulfonate 0.50 U Perfluorohexanoic acid 0. U Perfluorononanoic acid 0. U Perfluoro-octanesulfonate 0.70 U Perfluorooctanoic acid 0.30 U Perfluorotetradecanoic acid 0.30 U Perfluorotridecanoic acid 0.60 U Perfluoroundecanoic acid 0.30 U Batch number: B Sample number(s): UNSPK: P TOC Laboratory Duplicate Background (BKG) = the sample used in conjunction with the duplicate BKG Conc DUP Conc DUP RPD DUP RPD Max Batch number: B Sample number(s): BKG: P TOC * () 7 Batch number: A Sample number(s): BKG: P Moisture * 5 *- Outside of specification **-This limit was used in the evaluation of the final result for the blank () The result for one or both determinations was less than five times the LOQ. (2) The unspiked result was more than four times the spike added. P###### is indicative of a Background or Unspiked sample that is batch matrix QC and was not performed using a sample from this submission group. Page 6 of
80 Quality Control Summary Client Name: C. T. Male Associates Reported: 06/2/6 4:9 Group Number: *- Outside of specification **-This limit was used in the evaluation of the final result for the blank () The result for one or both determinations was less than five times the LOQ. (2) The unspiked result was more than four times the spike added. P###### is indicative of a Background or Unspiked sample that is batch matrix QC and was not performed using a sample from this submission group. Page 7 of
81 Page 8 of
82 Page 9 of
83 Page 0 of
84 Explanation of Symbols and Abbreviations The following defines common symbols and abbreviations used in reporting technical data: RL Reporting Limit BMQL Below Minimum Quantitation Level N.D. none detected MPN Most Probable Number TNTC Too Numerous To Count CP Units cobalt-chloroplatinate units IU International Units NTU nephelometric turbidity units umhos/cm micromhos/cm ng nanogram(s) C degrees Celsius F degrees Fahrenheit meq milliequivalents lb. pound(s) g gram(s) kg kilogram(s) µg microgram(s) mg milligram(s) ml milliliter(s) L liter(s) m3 cubic meter(s) µl microliter(s) pg/l picogram/liter < less than > greater than ppm parts per million - One ppm is equivalent to one milligram per kilogram () or one gram per million grams. For aqueous liquids, ppm is usually taken to be equivalent to milligrams per liter (mg/l), because one liter of water has a weight very close to a kilogram. For gases or vapors, one ppm is equivalent to one microliter per liter of gas. ppb parts per billion weight Results printed under this heading have been adjusted for moisture content. This increases the analyte weight basis concentration to approximate the value present in a similar sample without moisture. All other results are reported on an as-received basis. Laboratory Data Qualifiers: B - Analyte detected in the blank C - Result confirmed by reanalysis E - Concentration exceeds the calibration range J (or G, I, X) - estimated value the Method Detection Limit (MDL or DL) and < the Limit of Quantitation (LOQ or RL) P - Concentration difference between the primary and confirmation column >40. The lower result is reported. U - Analyte was not detected at the value indicated V - Concentration difference between the primary and confirmation column >00. The reporting limit is raised due to this disparity and evident interference Additional Organic and Inorganic CLP qualifiers may be used with Form reports as defined by the CLP methods. Qualifiers specific to Dioxin/Furans and PCB Congeners are detailed on the individual Analysis Report. Analytical test results meet all requirements of the associated regulatory program (i.e., NELAC (TNI), DoD, and ISO 7025) unless otherwise noted under the individual analysis. Measurement uncertainty values, as applicable, are available upon request. Tests results relate only to the sample tested. Clients should be aware that a critical step in a chemical or microbiological analysis is the collection of the sample. Unless the sample analyzed is truly representative of the bulk of material involved, the test results will be meaningless. If you have questions regarding the proper techniques of collecting samples, please contact us. We cannot be held responsible for sample integrity, however, unless sampling has been performed by a member of our staff. This report shall not be reproduced except in full, without the written approval of the laboratory. Times are local to the area of activity. Parameters listed in the 40 CFR Part 36 Table II as analyze immediately are not performed within 5 minutes. WARRANTY AND LIMITS OF LIABILITY - In accepting analytical work, we warrant the accuracy of test results for the sample as submitted. THE FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND IS GIVEN IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. WE DISCLAIM ANY OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING A WARRANTY OF FITNESS FOR PARTICULAR PURPOSE AND WARRANTY OF MERCHANTABILITY. IN NO EVENT SHALL EUROFINS LANCASTER LABORATORIES ENVIRONMENTAL, LLC BE LIABLE FOR INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES INCLUDING, BUT NOT LIMITED TO, DAMAGES FOR LOSS OF PROFIT OR GOODWILL REGARDLESS OF (A) THE NEGLIGENCE (EITHER SOLE OR CONCURRENT) OF EUROFINS LANCASTER LABORATORIES ENVIRONMENTAL AND (B) WHETHER EUROFINS LANCASTER LABORATORIES ENVIRONMENTAL HAS BEEN INFORMED OF THE POSSIBILITY OF SUCH DAMAGES. We accept no legal responsibility for the purposes for which the client uses the test results. No purchase order or other order for work shall be accepted by Eurofins Lancaster Laboratories Environmental which includes any conditions that vary from the Standard Terms and Conditions, and Eurofins Lancaster Laboratories Environmental hereby objects to any conflicting terms contained in any acceptance or order submitted by client Page of
85 REVISED ANALYTICAL RESULTS Prepared by: Eurofins Lancaster Laboratories Environmental 2425 New Holland Pike Lancaster, PA 760 Prepared for: C. T. Male Associates 50 Century Hill Drive Latham NY Report Date: September 28, 6 Project: SGPP - Merrimack Submittal Date: 04/30/6 Group Number: SDG: SGP39 PO Number: State of Sample Origin: NH Lancaster Labs Client Sample Description (LL) # A. Bball Outfield # 0"to6" Grab Soil A. Bball Outfield # 6"to2" Grab Soil A. Bball Outfield # 2"to8" Grab Soil A. Bball Outfield # 8"to24" Grab Soil The specific methodologies used in obtaining the enclosed analytical results are indicated on the Laboratory Sample Analysis Record. Regulatory agencies do not accredit laboratories for all methods, analytes, and matrices. Our current scopes of accreditation can be viewed at To request copies of prior scopes of accreditation, contact your project manager. Electronic Copy To C. T. Male Associates Attn: Dan Reilly Electronic Copy To C. T. Male Associates Attn: Kirk Moline Respectfully Submitted, (77) Page of 3
86 Case Narrative Project Name: SGPP - Merrimack LL Group #: General Comments: See the Laboratory Sample Analysis Record section of the Analysis Report for the method references. All QC met criteria unless otherwise noted in an Analysis Specific Comment below. Refer to the QC Summary for specific values and acceptance criteria. Project specific QC samples are not included in this data set Matrix QC may not be reported if site-specific QC samples were not submitted. In these situations, to demonstrate precision and accuracy at a batch level, a LCS/LCSD was performed, unless otherwise specified in the method. Surrogate recoveries (if applicable) which are outside of the QC window are confirmed unless attributed to a dilution or otherwise noted in an Analysis Specific Comment below. The samples were received at the appropriate temperature and in accordance with the chain of custody unless otherwise noted. Analysis Specific Comments: EPA 537 Rev.., Misc. Organics Sample #s: , , , The stated QC limits are advisory only until sufficient data points can be obtained to calculate statistical limits. Batch #: (Sample number(s): UNSPK: MS) The recovery(ies) for the following analyte(s) in the LCS exceeded the acceptance window indicating a positive bias: Perfluorotridecanoic acid, Perfluorotetradecanoic acid SM 530 B -00, Wet Chemistry Batch #: A (Sample number(s): UNSPK: P BKG: P357466) The duplicate RPD for the following analyte(s) exceeded the acceptance window: TOC Solids/Sludges Combustion Batch #: B (Sample number(s): UNSPK: BKG: ) The duplicate RPD for the following analyte(s) exceeded the acceptance window: TOC Solids/Sludges Combustion SM 2540 G-997, Wet Chemistry Batch #: A (Sample number(s): BKG: P359027) The duplicate RPD for the following analyte(s) exceeded the acceptance window: Moisture v.9.4 9/28/6 8:28:42AM Page 2 of 3
87 Sample Description: A. Bball Outfield # 0"to6" Grab Soil Reeds Ferry Elementary School Project Name: SGPP - Merrimack Collected: 04/28/6 5:0 Submitted: 04/30/6 0:30 Reported: 09/28/6 08:29 ABB- CAT No. SDG#: SGP39-0 by LC CAS Number Result C. T. Male Associates 50 Century Hill Drive Latham NY Method Detection Limit* REVISED LL Sample # SW LL Group # Account # 379 Limit of Quantitation Misc. Organics EPA 537 Rev Perfluorobutanesulfonate U Perfluorodecanoic acid U Perfluorododecanoic acid U Perfluoroheptanoic acid U Perfluorohexanesulfonate U Perfluorohexanoic acid U Perfluorononanoic acid J Perfluoro-octanesulfonate J Perfluorooctanoic acid Perfluorotetradecanoic acid U Perfluorotridecanoic acid U Perfluoroundecanoic acid U The stated QC limits are advisory only until sufficient data points can be obtained to calculate statistical limits. Wet Chemistry SM 530 B TOC n.a. 9, ,370 Wet Chemistry SM 2540 G Moisture n.a Moisture represents the loss in weight of the sample after oven drying at degrees Celsius. The moisture result reported is on an as-received basis. Dilution Factor Sample Comments All QC is compliant unless otherwise noted. Please refer to the Quality Control Summary for overall QC performance data and associated samples. Laboratory Sample Analysis Record CAT No. Method Trial# Batch# Analysis Date and Time Analyst Dilution Factor 4027 Full List PFC's EPA 537 Rev /4/6 22:54 Marissa C Drexinger 4090 PFC Solid Prep EPA 537 Rev //6 8:23 Jason W Knight 079 TOC SM 530 B A 05/06/6 00:30 James S Mathiot Moisture SM 2540 G A 05/05/6 3:45 Larry E Bevins *=This limit was used in the evaluation of the final result Page 3 of 3
88 Sample Description: A. Bball Outfield # 6"to2" Grab Soil Reeds Ferry Elementary School Project Name: SGPP - Merrimack Collected: 04/28/6 5:5 Submitted: 04/30/6 0:30 Reported: 09/28/6 08:29 ABB-2 CAT No. SDG#: SGP39-02 by LC CAS Number Result C. T. Male Associates 50 Century Hill Drive Latham NY Method Detection Limit* REVISED LL Sample # SW LL Group # Account # 379 Limit of Quantitation Misc. Organics EPA 537 Rev Perfluorobutanesulfonate U Perfluorodecanoic acid U Perfluorododecanoic acid U Perfluoroheptanoic acid U Perfluorohexanesulfonate U Perfluorohexanoic acid U Perfluorononanoic acid U Perfluoro-octanesulfonate U Perfluorooctanoic acid Perfluorotetradecanoic acid U Perfluorotridecanoic acid U Perfluoroundecanoic acid U The stated QC limits are advisory only until sufficient data points can be obtained to calculate statistical limits. Wet Chemistry SM 530 B TOC n.a. 2, Wet Chemistry SM 2540 G Moisture n.a Moisture represents the loss in weight of the sample after oven drying at degrees Celsius. The moisture result reported is on an as-received basis. Dilution Factor Sample Comments All QC is compliant unless otherwise noted. Please refer to the Quality Control Summary for overall QC performance data and associated samples. Laboratory Sample Analysis Record CAT No. Method Trial# Batch# Analysis Date and Time Analyst Dilution Factor 4027 Full List PFC's EPA 537 Rev /4/6 23:3 Marissa C Drexinger 4090 PFC Solid Prep EPA 537 Rev //6 8:23 Jason W Knight 079 TOC SM 530 B A 05/06/6 00:37 James S Mathiot Moisture SM 2540 G A 05/05/6 3:45 Larry E Bevins *=This limit was used in the evaluation of the final result Page 4 of 3
89 Sample Description: A. Bball Outfield # 2"to8" Grab Soil Reeds Ferry Elementary School Project Name: SGPP - Merrimack Collected: 04/28/6 5:2 Submitted: 04/30/6 0:30 Reported: 09/28/6 08:29 ABB-3 CAT No. SDG#: SGP39-03 by LC CAS Number Result C. T. Male Associates 50 Century Hill Drive Latham NY Method Detection Limit* REVISED LL Sample # SW LL Group # Account # 379 Limit of Quantitation Misc. Organics EPA 537 Rev Perfluorobutanesulfonate U Perfluorodecanoic acid U Perfluorododecanoic acid U Perfluoroheptanoic acid U Perfluorohexanesulfonate U Perfluorohexanoic acid U Perfluorononanoic acid U Perfluoro-octanesulfonate U Perfluorooctanoic acid Perfluorotetradecanoic acid U Perfluorotridecanoic acid U Perfluoroundecanoic acid U The stated QC limits are advisory only until sufficient data points can be obtained to calculate statistical limits. Wet Chemistry SM 530 B TOC n.a., Wet Chemistry SM 2540 G Moisture n.a Moisture represents the loss in weight of the sample after oven drying at degrees Celsius. The moisture result reported is on an as-received basis. Dilution Factor Sample Comments All QC is compliant unless otherwise noted. Please refer to the Quality Control Summary for overall QC performance data and associated samples. Laboratory Sample Analysis Record CAT No. Method Trial# Batch# Analysis Date and Time Analyst Dilution Factor 4027 Full List PFC's EPA 537 Rev /4/6 23:32 Marissa C Drexinger 4090 PFC Solid Prep EPA 537 Rev //6 8:23 Jason W Knight 079 TOC SM 530 B B 05/06/6 0:06 James S Mathiot Moisture SM 2540 G A 05/05/6 3:45 Larry E Bevins *=This limit was used in the evaluation of the final result Page 5 of 3
90 Sample Description: A. Bball Outfield # 8"to24" Grab Soil Reeds Ferry Elementary School Project Name: SGPP - Merrimack Collected: 04/28/6 5:26 Submitted: 04/30/6 0:30 Reported: 09/28/6 08:29 ABB-4 CAT No. SDG#: SGP39-04 by LC CAS Number Result C. T. Male Associates 50 Century Hill Drive Latham NY Method Detection Limit* REVISED LL Sample # SW LL Group # Account # 379 Limit of Quantitation Misc. Organics EPA 537 Rev Perfluorobutanesulfonate U Perfluorodecanoic acid U Perfluorododecanoic acid U Perfluoroheptanoic acid U Perfluorohexanesulfonate U Perfluorohexanoic acid U Perfluorononanoic acid U Perfluoro-octanesulfonate U Perfluorooctanoic acid Perfluorotetradecanoic acid U Perfluorotridecanoic acid U Perfluoroundecanoic acid U The stated QC limits are advisory only until sufficient data points can be obtained to calculate statistical limits. Wet Chemistry SM 530 B TOC n.a., Wet Chemistry SM 2540 G Moisture n.a Moisture represents the loss in weight of the sample after oven drying at degrees Celsius. The moisture result reported is on an as-received basis. Dilution Factor Sample Comments All QC is compliant unless otherwise noted. Please refer to the Quality Control Summary for overall QC performance data and associated samples. Laboratory Sample Analysis Record CAT No. Method Trial# Batch# Analysis Date and Time Analyst Dilution Factor 4027 Full List PFC's EPA 537 Rev /4/6 23:5 Marissa C Drexinger 4090 PFC Solid Prep EPA 537 Rev //6 8:23 Jason W Knight 079 TOC SM 530 B B 05/06/6 0:35 James S Mathiot Moisture SM 2540 G A 05/05/6 3:45 Larry E Bevins *=This limit was used in the evaluation of the final result Page 6 of 3
91 REVISED Quality Control Summary Client Name: C. T. Male Associates Reported: 09/28/6 08:29 Group Number: Matrix QC may not be reported if insufficient sample or site-specific QC samples were not submitted. In these situations, to demonstrate precision and accuracy at a batch level, a LCS/LCSD was performed, unless otherwise specified in the method. All Inorganic Initial Calibration and Continuing Calibration Blanks met acceptable method criteria unless otherwise noted on the Analysis Report. Method Blank Result MDL** LOQ Batch number: Sample number(s): Perfluorobutanesulfonate 0.50 U Perfluorodecanoic acid 0. U Perfluorododecanoic acid 0.40 U Perfluoroheptanoic acid 0.30 U Perfluorohexanesulfonate 0.50 U Perfluorohexanoic acid 0. U Perfluorononanoic acid 0. U Perfluoro-octanesulfonate 0.70 U Perfluorooctanoic acid 0.30 U Perfluorotetradecanoic acid 0.30 U Perfluorotridecanoic acid 0.60 U Perfluoroundecanoic acid 0.30 U Batch number: A Sample number(s): TOC 00 U Batch number: B Sample number(s): TOC 00 U LCS/LCSD LCS Spike LCS LCSD Spike LCSD Added Conc Added Conc LCS REC LCSD REC LCS/LCSD Limits RPD RPD Max Batch number: Sample number(s): Perfluorobutanesulfonate Perfluorodecanoic acid 9.5 Perfluorododecanoic acid 8 Perfluoroheptanoic acid.7 Perfluorohexanesulfonate Perfluorohexanoic acid 8.5 Perfluorononanoic acid.5 Perfluoro-octanesulfonate Perfluorooctanoic acid 5.7 Perfluorotetradecanoic acid 37.5 Perfluorotridecanoic acid 27.6 Perfluoroundecanoic acid * 38* *- Outside of specification **-This limit was used in the evaluation of the final result for the blank () The result for one or both determinations was less than five times the LOQ. (2) The unspiked result was more than four times the spike added. P###### is indicative of a Background or Unspiked sample that is batch matrix QC and was not performed using a sample from this submission group. Page 7 of 3
92 REVISED Quality Control Summary Client Name: C. T. Male Associates Reported: 09/28/6 08:29 Group Number: LCS/LCSD (continued) LCS Spike LCS LCSD Spike LCSD Added Conc Added Conc LCS REC LCSD REC LCS/LCSD Limits RPD RPD Max Batch number: A Sample number(s): TOC Batch number: B Sample number(s): TOC Batch number: A Sample number(s): Moisture MS/MSD Unspiked (UNSPK) = the sample used in conjunction with the matrix spike Unspiked Conc MS Spike Added MS Conc MSD Spike Added MSD Conc MS Rec MSD Rec MS/MSD Limits RPD RPD Max Batch number: Sample number(s): UNSPK: Perfluorobutanesulfonate 0.50 U Perfluorodecanoic acid 0. U Perfluorododecanoic acid 0.40 U Perfluoroheptanoic acid 0.30 U Perfluorohexanesulfonate 0.50 U Perfluorohexanoic acid 0. U Perfluorononanoic acid 0. U Perfluoro-octanesulfonate 0.70 U Perfluorooctanoic acid Perfluorotetradecanoic acid 0.30 U Perfluorotridecanoic acid 0.60 U Perfluoroundecanoic acid 0.30 U Batch number: A Sample number(s): UNSPK: P TOC Batch number: B Sample number(s): UNSPK: TOC Laboratory Duplicate Background (BKG) = the sample used in conjunction with the duplicate BKG Conc DUP Conc DUP RPD DUP RPD Max *- Outside of specification **-This limit was used in the evaluation of the final result for the blank () The result for one or both determinations was less than five times the LOQ. (2) The unspiked result was more than four times the spike added. P###### is indicative of a Background or Unspiked sample that is batch matrix QC and was not performed using a sample from this submission group. Page 8 of 3
93 REVISED Quality Control Summary Client Name: C. T. Male Associates Reported: 09/28/6 08:29 Group Number: Laboratory Duplicate Background (BKG) = the sample used in conjunction with the duplicate BKG Conc DUP Conc DUP RPD DUP RPD Max Batch number: A Sample number(s): BKG: P TOC * () 7 Batch number: B Sample number(s): BKG: TOC * () 7 Batch number: A Sample number(s): BKG: P Moisture * 5 *- Outside of specification **-This limit was used in the evaluation of the final result for the blank () The result for one or both determinations was less than five times the LOQ. (2) The unspiked result was more than four times the spike added. P###### is indicative of a Background or Unspiked sample that is batch matrix QC and was not performed using a sample from this submission group. Page 9 of 3
94 Page 0 of 3
95 Page of 3
96 Page 2 of 3
97 Explanation of Symbols and Abbreviations The following defines common symbols and abbreviations used in reporting technical data: RL Reporting Limit BMQL Below Minimum Quantitation Level N.D. none detected MPN Most Probable Number TNTC Too Numerous To Count CP Units cobalt-chloroplatinate units IU International Units NTU nephelometric turbidity units umhos/cm micromhos/cm ng nanogram(s) C degrees Celsius F degrees Fahrenheit meq milliequivalents lb. pound(s) g gram(s) kg kilogram(s) µg microgram(s) mg milligram(s) ml milliliter(s) L liter(s) m3 cubic meter(s) µl microliter(s) pg/l picogram/liter < less than > greater than ppm parts per million - One ppm is equivalent to one milligram per kilogram () or one gram per million grams. For aqueous liquids, ppm is usually taken to be equivalent to milligrams per liter (mg/l), because one liter of water has a weight very close to a kilogram. For gases or vapors, one ppm is equivalent to one microliter per liter of gas. ppb parts per billion weight Results printed under this heading have been adjusted for moisture content. This increases the analyte weight basis concentration to approximate the value present in a similar sample without moisture. All other results are reported on an as-received basis. Laboratory Data Qualifiers: B - Analyte detected in the blank C - Result confirmed by reanalysis E - Concentration exceeds the calibration range J (or G, I, X) - estimated value the Method Detection Limit (MDL or DL) and < the Limit of Quantitation (LOQ or RL) P - Concentration difference between the primary and confirmation column >40. The lower result is reported. U - Analyte was not detected at the value indicated V - Concentration difference between the primary and confirmation column >00. The reporting limit is raised due to this disparity and evident interference Additional Organic and Inorganic CLP qualifiers may be used with Form reports as defined by the CLP methods. Qualifiers specific to Dioxin/Furans and PCB Congeners are detailed on the individual Analysis Report. Analytical test results meet all requirements of the associated regulatory program (i.e., NELAC (TNI), DoD, and ISO 7025) unless otherwise noted under the individual analysis. Measurement uncertainty values, as applicable, are available upon request. Tests results relate only to the sample tested. Clients should be aware that a critical step in a chemical or microbiological analysis is the collection of the sample. Unless the sample analyzed is truly representative of the bulk of material involved, the test results will be meaningless. If you have questions regarding the proper techniques of collecting samples, please contact us. We cannot be held responsible for sample integrity, however, unless sampling has been performed by a member of our staff. This report shall not be reproduced except in full, without the written approval of the laboratory. Times are local to the area of activity. Parameters listed in the 40 CFR Part 36 Table II as analyze immediately are not performed within 5 minutes. WARRANTY AND LIMITS OF LIABILITY - In accepting analytical work, we warrant the accuracy of test results for the sample as submitted. THE FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND IS GIVEN IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. WE DISCLAIM ANY OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING A WARRANTY OF FITNESS FOR PARTICULAR PURPOSE AND WARRANTY OF MERCHANTABILITY. IN NO EVENT SHALL EUROFINS LANCASTER LABORATORIES ENVIRONMENTAL, LLC BE LIABLE FOR INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES INCLUDING, BUT NOT LIMITED TO, DAMAGES FOR LOSS OF PROFIT OR GOODWILL REGARDLESS OF (A) THE NEGLIGENCE (EITHER SOLE OR CONCURRENT) OF EUROFINS LANCASTER LABORATORIES ENVIRONMENTAL AND (B) WHETHER EUROFINS LANCASTER LABORATORIES ENVIRONMENTAL HAS BEEN INFORMED OF THE POSSIBILITY OF SUCH DAMAGES. We accept no legal responsibility for the purposes for which the client uses the test results. No purchase order or other order for work shall be accepted by Eurofins Lancaster Laboratories Environmental which includes any conditions that vary from the Standard Terms and Conditions, and Eurofins Lancaster Laboratories Environmental hereby objects to any conflicting terms contained in any acceptance or order submitted by client Page 3 of 3
98 REVISED ANALYTICAL RESULTS Prepared by: Eurofins Lancaster Laboratories Environmental 2425 New Holland Pike Lancaster, PA 760 Prepared for: C. T. Male Associates 50 Century Hill Drive Latham NY Report Date: September 28, 6 Project: SGPP - Merrimack Submittal Date: 04/30/6 Group Number: SDG: SGP38 PO Number: State of Sample Origin: NH Lancaster Labs Client Sample Description (LL) # C. Lacrosse Field # 0"to6" Grab Soil C. Lacrosse Field # 6"to2" Grab Soil C. Lacrosse Field # 2"to8" Grab Soil C. Lacrosse Field # 8"to24" Grab Soil The specific methodologies used in obtaining the enclosed analytical results are indicated on the Laboratory Sample Analysis Record. Regulatory agencies do not accredit laboratories for all methods, analytes, and matrices. Our current scopes of accreditation can be viewed at To request copies of prior scopes of accreditation, contact your project manager. Electronic Copy To C. T. Male Associates Attn: Dan Reilly Electronic Copy To C. T. Male Associates Attn: Kirk Moline Respectfully Submitted, (77) Page of 3
99 Case Narrative Project Name: SGPP - Merrimack LL Group #: General Comments: See the Laboratory Sample Analysis Record section of the Analysis Report for the method references. All QC met criteria unless otherwise noted in an Analysis Specific Comment below. Refer to the QC Summary for specific values and acceptance criteria. Project specific QC samples are not included in this data set Matrix QC may not be reported if site-specific QC samples were not submitted. In these situations, to demonstrate precision and accuracy at a batch level, a LCS/LCSD was performed, unless otherwise specified in the method. Surrogate recoveries (if applicable) which are outside of the QC window are confirmed unless attributed to a dilution or otherwise noted in an Analysis Specific Comment below. The samples were received at the appropriate temperature and in accordance with the chain of custody unless otherwise noted. Analysis Specific Comments: EPA 537 Rev.., Misc. Organics Sample #s: , , , The stated QC limits are advisory only until sufficient data points can be obtained to calculate statistical limits. Batch #: (Sample number(s): UNSPK: MS) The recovery(ies) for the following analyte(s) in the LCS exceeded the acceptance window indicating a positive bias: Perfluorotridecanoic acid, Perfluorotetradecanoic acid SM 530 B -00, Wet Chemistry Batch #: A (Sample number(s): UNSPK: P BKG: P357466) The duplicate RPD for the following analyte(s) exceeded the acceptance window: TOC Solids/Sludges Combustion v.9.4 9/28/6 8:30:27AM Page 2 of 3
100 Sample Description: C. Lacrosse Field # 0"to6" Grab Soil Reeds Ferry Elementary School Project Name: SGPP - Merrimack Collected: 04/28/6 4:28 Submitted: 04/30/6 0:30 Reported: 09/28/6 08:3 CLF- CAT No. SDG#: SGP38-0 by LC CAS Number Result C. T. Male Associates 50 Century Hill Drive Latham NY Method Detection Limit* REVISED LL Sample # SW LL Group # Account # 379 Limit of Quantitation Misc. Organics EPA 537 Rev Perfluorobutanesulfonate U Perfluorodecanoic acid Perfluorododecanoic acid Perfluoroheptanoic acid U Perfluorohexanesulfonate U Perfluorohexanoic acid J Perfluorononanoic acid Perfluoro-octanesulfonate Perfluorooctanoic acid Perfluorotetradecanoic acid J Perfluorotridecanoic acid U Perfluoroundecanoic acid J The stated QC limits are advisory only until sufficient data points can be obtained to calculate statistical limits. Wet Chemistry SM 530 B TOC n.a. 5, , Wet Chemistry SM 2540 G Moisture n.a Moisture represents the loss in weight of the sample after oven drying at degrees Celsius. The moisture result reported is on an as-received basis. Dilution Factor Sample Comments All QC is compliant unless otherwise noted. Please refer to the Quality Control Summary for overall QC performance data and associated samples. Laboratory Sample Analysis Record CAT No. Method Trial# Batch# Analysis Date and Time Analyst Dilution Factor 4027 Full List PFC's EPA 537 Rev /4/6 2:7 Marissa C Drexinger 4090 PFC Solid Prep EPA 537 Rev //6 8:23 Jason W Knight 079 TOC SM 530 B A 05/06/6 00:54 James S Mathiot Moisture SM 2540 G A 05/05/6 9: Scott W Freisher *=This limit was used in the evaluation of the final result Page 3 of 3
101 Sample Description: C. Lacrosse Field # 6"to2" Grab Soil Reeds Ferry Elementary School Project Name: SGPP - Merrimack Collected: 04/28/6 4:35 Submitted: 04/30/6 0:30 Reported: 09/28/6 08:3 CLF-2 CAT No. SDG#: SGP38-02 by LC CAS Number Result C. T. Male Associates 50 Century Hill Drive Latham NY Method Detection Limit* REVISED LL Sample # SW LL Group # Account # 379 Limit of Quantitation Misc. Organics EPA 537 Rev Perfluorobutanesulfonate U Perfluorodecanoic acid U Perfluorododecanoic acid U Perfluoroheptanoic acid U Perfluorohexanesulfonate U Perfluorohexanoic acid U Perfluorononanoic acid Perfluoro-octanesulfonate Perfluorooctanoic acid Perfluorotetradecanoic acid U Perfluorotridecanoic acid U Perfluoroundecanoic acid U The stated QC limits are advisory only until sufficient data points can be obtained to calculate statistical limits. Wet Chemistry SM 530 B TOC n.a. 4, ,30 Wet Chemistry SM 2540 G Moisture n.a Moisture represents the loss in weight of the sample after oven drying at degrees Celsius. The moisture result reported is on an as-received basis. Dilution Factor Sample Comments All QC is compliant unless otherwise noted. Please refer to the Quality Control Summary for overall QC performance data and associated samples. Laboratory Sample Analysis Record CAT No. Method Trial# Batch# Analysis Date and Time Analyst Dilution Factor 4027 Full List PFC's EPA 537 Rev /4/6 2:36 Marissa C Drexinger 4090 PFC Solid Prep EPA 537 Rev //6 8:23 Jason W Knight 079 TOC SM 530 B A 05/05/6 23:09 James S Mathiot Moisture SM 2540 G A 05/05/6 9: Scott W Freisher *=This limit was used in the evaluation of the final result Page 4 of 3
102 Sample Description: C. Lacrosse Field # 2"to8" Grab Soil Reeds Ferry Elementary School Project Name: SGPP - Merrimack Collected: 04/28/6 4:40 Submitted: 04/30/6 0:30 Reported: 09/28/6 08:3 CLF-3 CAT No. SDG#: SGP38-03 by LC CAS Number Result C. T. Male Associates 50 Century Hill Drive Latham NY Method Detection Limit* REVISED LL Sample # SW LL Group # Account # 379 Limit of Quantitation Misc. Organics EPA 537 Rev Perfluorobutanesulfonate U Perfluorodecanoic acid U Perfluorododecanoic acid U Perfluoroheptanoic acid U Perfluorohexanesulfonate U Perfluorohexanoic acid J Perfluorononanoic acid U Perfluoro-octanesulfonate J Perfluorooctanoic acid Perfluorotetradecanoic acid U Perfluorotridecanoic acid U Perfluoroundecanoic acid U The stated QC limits are advisory only until sufficient data points can be obtained to calculate statistical limits. Wet Chemistry SM 530 B TOC n.a. 2, Wet Chemistry SM 2540 G Moisture n.a Moisture represents the loss in weight of the sample after oven drying at degrees Celsius. The moisture result reported is on an as-received basis. Dilution Factor Sample Comments All QC is compliant unless otherwise noted. Please refer to the Quality Control Summary for overall QC performance data and associated samples. Laboratory Sample Analysis Record CAT No. Method Trial# Batch# Analysis Date and Time Analyst Dilution Factor 4027 Full List PFC's EPA 537 Rev /4/6 22:5 Marissa C Drexinger 4090 PFC Solid Prep EPA 537 Rev //6 8:23 Jason W Knight 079 TOC SM 530 B A 05/05/6 23:36 James S Mathiot Moisture SM 2540 G A 05/05/6 9: Scott W Freisher *=This limit was used in the evaluation of the final result Page 5 of 3
103 Sample Description: C. Lacrosse Field # 8"to24" Grab Soil Reeds Ferry Elementary School Project Name: SGPP - Merrimack Collected: 04/28/6 4:45 Submitted: 04/30/6 0:30 Reported: 09/28/6 08:3 CLF-4 CAT No. SDG#: SGP38-04 by LC CAS Number Result C. T. Male Associates 50 Century Hill Drive Latham NY Method Detection Limit* REVISED LL Sample # SW LL Group # Account # 379 Limit of Quantitation Misc. Organics EPA 537 Rev Perfluorobutanesulfonate U Perfluorodecanoic acid U Perfluorododecanoic acid U Perfluoroheptanoic acid U Perfluorohexanesulfonate U Perfluorohexanoic acid J Perfluorononanoic acid U Perfluoro-octanesulfonate U Perfluorooctanoic acid Perfluorotetradecanoic acid U Perfluorotridecanoic acid U Perfluoroundecanoic acid U The stated QC limits are advisory only until sufficient data points can be obtained to calculate statistical limits. Wet Chemistry SM 530 B TOC n.a., Wet Chemistry SM 2540 G Moisture n.a Moisture represents the loss in weight of the sample after oven drying at degrees Celsius. The moisture result reported is on an as-received basis. Dilution Factor Sample Comments All QC is compliant unless otherwise noted. Please refer to the Quality Control Summary for overall QC performance data and associated samples. Laboratory Sample Analysis Record CAT No. Method Trial# Batch# Analysis Date and Time Analyst Dilution Factor 4027 Full List PFC's EPA 537 Rev /4/6 22:34 Marissa C Drexinger 4090 PFC Solid Prep EPA 537 Rev //6 8:23 Jason W Knight 079 TOC SM 530 B A 05/06/6 00:22 James S Mathiot Moisture SM 2540 G A 05/05/6 9: Scott W Freisher *=This limit was used in the evaluation of the final result Page 6 of 3
104 REVISED Quality Control Summary Client Name: C. T. Male Associates Reported: 09/28/6 08:3 Group Number: Matrix QC may not be reported if insufficient sample or site-specific QC samples were not submitted. In these situations, to demonstrate precision and accuracy at a batch level, a LCS/LCSD was performed, unless otherwise specified in the method. All Inorganic Initial Calibration and Continuing Calibration Blanks met acceptable method criteria unless otherwise noted on the Analysis Report. Method Blank Result MDL** LOQ Batch number: Sample number(s): Perfluorobutanesulfonate 0.50 U Perfluorodecanoic acid 0. U Perfluorododecanoic acid 0.40 U Perfluoroheptanoic acid 0.30 U Perfluorohexanesulfonate 0.50 U Perfluorohexanoic acid 0. U Perfluorononanoic acid 0. U Perfluoro-octanesulfonate 0.70 U Perfluorooctanoic acid 0.30 U Perfluorotetradecanoic acid 0.30 U Perfluorotridecanoic acid 0.60 U Perfluoroundecanoic acid 0.30 U Batch number: A Sample number(s): TOC 00 U LCS/LCSD LCS Spike LCS LCSD Spike LCSD Added Conc Added Conc LCS REC LCSD REC LCS/LCSD Limits RPD RPD Max Batch number: Sample number(s): Perfluorobutanesulfonate Perfluorodecanoic acid 9.5 Perfluorododecanoic acid 8 Perfluoroheptanoic acid.7 Perfluorohexanesulfonate Perfluorohexanoic acid 8.5 Perfluorononanoic acid.5 Perfluoro-octanesulfonate Perfluorooctanoic acid 5.7 Perfluorotetradecanoic acid 37.5 Perfluorotridecanoic acid 27.6 Perfluoroundecanoic acid * 38* Batch number: A Sample number(s): TOC *- Outside of specification **-This limit was used in the evaluation of the final result for the blank () The result for one or both determinations was less than five times the LOQ. (2) The unspiked result was more than four times the spike added. P###### is indicative of a Background or Unspiked sample that is batch matrix QC and was not performed using a sample from this submission group. Page 7 of 3
105 REVISED Quality Control Summary Client Name: C. T. Male Associates Reported: 09/28/6 08:3 Group Number: LCS/LCSD (continued) LCS Spike LCS LCSD Spike LCSD Added Conc Added Conc LCS REC LCSD REC LCS/LCSD Limits RPD RPD Max Batch number: A Sample number(s): Moisture MS/MSD Unspiked (UNSPK) = the sample used in conjunction with the matrix spike Unspiked Conc MS Spike Added MS Conc MSD Spike Added MSD Conc MS Rec MSD Rec MS/MSD Limits RPD RPD Max Batch number: Sample number(s): UNSPK: Perfluorobutanesulfonate 0.50 U Perfluorodecanoic acid 0. U Perfluorododecanoic acid 0.40 U Perfluoroheptanoic acid 0.30 U Perfluorohexanesulfonate 0.50 U Perfluorohexanoic acid 0. U Perfluorononanoic acid 0. U Perfluoro-octanesulfonate 0.70 U Perfluorooctanoic acid Perfluorotetradecanoic acid 0.30 U Perfluorotridecanoic acid 0.60 U Perfluoroundecanoic acid 0.30 U Batch number: A Sample number(s): UNSPK: P TOC Laboratory Duplicate Background (BKG) = the sample used in conjunction with the duplicate BKG Conc DUP Conc DUP RPD DUP RPD Max Batch number: A Sample number(s): BKG: P TOC * () 7 Batch number: A Sample number(s): BKG: Moisture *- Outside of specification **-This limit was used in the evaluation of the final result for the blank () The result for one or both determinations was less than five times the LOQ. (2) The unspiked result was more than four times the spike added. P###### is indicative of a Background or Unspiked sample that is batch matrix QC and was not performed using a sample from this submission group. Page 8 of 3
106 REVISED Quality Control Summary Client Name: C. T. Male Associates Reported: 09/28/6 08:3 Group Number: *- Outside of specification **-This limit was used in the evaluation of the final result for the blank () The result for one or both determinations was less than five times the LOQ. (2) The unspiked result was more than four times the spike added. P###### is indicative of a Background or Unspiked sample that is batch matrix QC and was not performed using a sample from this submission group. Page 9 of 3
107 Page 0 of 3
108 Page of 3
109 Page 2 of 3
110 Explanation of Symbols and Abbreviations The following defines common symbols and abbreviations used in reporting technical data: RL Reporting Limit BMQL Below Minimum Quantitation Level N.D. none detected MPN Most Probable Number TNTC Too Numerous To Count CP Units cobalt-chloroplatinate units IU International Units NTU nephelometric turbidity units umhos/cm micromhos/cm ng nanogram(s) C degrees Celsius F degrees Fahrenheit meq milliequivalents lb. pound(s) g gram(s) kg kilogram(s) µg microgram(s) mg milligram(s) ml milliliter(s) L liter(s) m3 cubic meter(s) µl microliter(s) pg/l picogram/liter < less than > greater than ppm parts per million - One ppm is equivalent to one milligram per kilogram () or one gram per million grams. For aqueous liquids, ppm is usually taken to be equivalent to milligrams per liter (mg/l), because one liter of water has a weight very close to a kilogram. For gases or vapors, one ppm is equivalent to one microliter per liter of gas. ppb parts per billion weight Results printed under this heading have been adjusted for moisture content. This increases the analyte weight basis concentration to approximate the value present in a similar sample without moisture. All other results are reported on an as-received basis. Laboratory Data Qualifiers: B - Analyte detected in the blank C - Result confirmed by reanalysis E - Concentration exceeds the calibration range J (or G, I, X) - estimated value the Method Detection Limit (MDL or DL) and < the Limit of Quantitation (LOQ or RL) P - Concentration difference between the primary and confirmation column >40. The lower result is reported. U - Analyte was not detected at the value indicated V - Concentration difference between the primary and confirmation column >00. The reporting limit is raised due to this disparity and evident interference Additional Organic and Inorganic CLP qualifiers may be used with Form reports as defined by the CLP methods. Qualifiers specific to Dioxin/Furans and PCB Congeners are detailed on the individual Analysis Report. Analytical test results meet all requirements of the associated regulatory program (i.e., NELAC (TNI), DoD, and ISO 7025) unless otherwise noted under the individual analysis. Measurement uncertainty values, as applicable, are available upon request. Tests results relate only to the sample tested. Clients should be aware that a critical step in a chemical or microbiological analysis is the collection of the sample. Unless the sample analyzed is truly representative of the bulk of material involved, the test results will be meaningless. If you have questions regarding the proper techniques of collecting samples, please contact us. We cannot be held responsible for sample integrity, however, unless sampling has been performed by a member of our staff. This report shall not be reproduced except in full, without the written approval of the laboratory. Times are local to the area of activity. Parameters listed in the 40 CFR Part 36 Table II as analyze immediately are not performed within 5 minutes. WARRANTY AND LIMITS OF LIABILITY - In accepting analytical work, we warrant the accuracy of test results for the sample as submitted. THE FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND IS GIVEN IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. WE DISCLAIM ANY OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING A WARRANTY OF FITNESS FOR PARTICULAR PURPOSE AND WARRANTY OF MERCHANTABILITY. IN NO EVENT SHALL EUROFINS LANCASTER LABORATORIES ENVIRONMENTAL, LLC BE LIABLE FOR INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES INCLUDING, BUT NOT LIMITED TO, DAMAGES FOR LOSS OF PROFIT OR GOODWILL REGARDLESS OF (A) THE NEGLIGENCE (EITHER SOLE OR CONCURRENT) OF EUROFINS LANCASTER LABORATORIES ENVIRONMENTAL AND (B) WHETHER EUROFINS LANCASTER LABORATORIES ENVIRONMENTAL HAS BEEN INFORMED OF THE POSSIBILITY OF SUCH DAMAGES. We accept no legal responsibility for the purposes for which the client uses the test results. No purchase order or other order for work shall be accepted by Eurofins Lancaster Laboratories Environmental which includes any conditions that vary from the Standard Terms and Conditions, and Eurofins Lancaster Laboratories Environmental hereby objects to any conflicting terms contained in any acceptance or order submitted by client Page 3 of 3
111 REVISED ANALYTICAL RESULTS Prepared by: Eurofins Lancaster Laboratories Environmental 2425 New Holland Pike Lancaster, PA 760 Prepared for: C. T. Male Associates 50 Century Hill Drive Latham NY Report Date: September 28, 6 Project: SGPP - Merrimack Submittal Date: 04/30/6 Group Number: SDG: SGP37 PO Number: State of Sample Origin: NH Lancaster Labs Client Sample Description (LL) # D. Lacrosse Field #2 0"to6" Grab Soil D. Lacrosse Field #2 6"to2" Grab Soil The specific methodologies used in obtaining the enclosed analytical results are indicated on the Laboratory Sample Analysis Record. Regulatory agencies do not accredit laboratories for all methods, analytes, and matrices. Our current scopes of accreditation can be viewed at To request copies of prior scopes of accreditation, contact your project manager. Electronic Copy To C. T. Male Associates Attn: Dan Reilly Electronic Copy To C. T. Male Associates Attn: Kirk Moline Respectfully Submitted, (77) Page of
112 Case Narrative Project Name: SGPP - Merrimack LL Group #: General Comments: See the Laboratory Sample Analysis Record section of the Analysis Report for the method references. All QC met criteria unless otherwise noted in an Analysis Specific Comment below. Refer to the QC Summary for specific values and acceptance criteria. Project specific QC samples are not included in this data set Matrix QC may not be reported if site-specific QC samples were not submitted. In these situations, to demonstrate precision and accuracy at a batch level, a LCS/LCSD was performed, unless otherwise specified in the method. Surrogate recoveries (if applicable) which are outside of the QC window are confirmed unless attributed to a dilution or otherwise noted in an Analysis Specific Comment below. The samples were received at the appropriate temperature and in accordance with the chain of custody unless otherwise noted. Analysis Specific Comments: EPA 537 Rev.., Misc. Organics Sample #s: , The stated QC limits are advisory only until sufficient data points can be obtained to calculate statistical limits. Batch #: (Sample number(s): UNSPK: MS) The recovery(ies) for the following analyte(s) in the LCS exceeded the acceptance window indicating a positive bias: Perfluorotridecanoic acid, Perfluorotetradecanoic acid SM 530 B -00, Wet Chemistry Batch #: A (Sample number(s): UNSPK: P BKG: P357466) The duplicate RPD for the following analyte(s) exceeded the acceptance window: TOC Solids/Sludges Combustion v.9.4 9/28/6 8:29:7AM Page 2 of
113 Sample Description: D. Lacrosse Field #2 0"to6" Grab Soil Reeds Ferry Elementary School Project Name: SGPP - Merrimack Collected: 04/28/6 4:05 Submitted: 04/30/6 0:30 Reported: 09/28/6 08:30 DLF- CAT No. SDG#: SGP37-0 by LC CAS Number Result C. T. Male Associates 50 Century Hill Drive Latham NY Method Detection Limit* REVISED LL Sample # SW LL Group # Account # 379 Limit of Quantitation Misc. Organics EPA 537 Rev Perfluorobutanesulfonate U Perfluorodecanoic acid Perfluorododecanoic acid Perfluoroheptanoic acid U Perfluorohexanesulfonate U Perfluorohexanoic acid Perfluorononanoic acid Perfluoro-octanesulfonate Perfluorooctanoic acid Perfluorotetradecanoic acid J Perfluorotridecanoic acid U Perfluoroundecanoic acid The stated QC limits are advisory only until sufficient data points can be obtained to calculate statistical limits. Wet Chemistry SM 530 B TOC n.a., ,4 Wet Chemistry SM 2540 G Moisture n.a Moisture represents the loss in weight of the sample after oven drying at degrees Celsius. The moisture result reported is on an as-received basis. Dilution Factor Sample Comments All QC is compliant unless otherwise noted. Please refer to the Quality Control Summary for overall QC performance data and associated samples. Laboratory Sample Analysis Record CAT No. Method Trial# Batch# Analysis Date and Time Analyst Dilution Factor 4027 Full List PFC's EPA 537 Rev /4/6 :38 Marissa C Drexinger 4090 PFC Solid Prep EPA 537 Rev //6 8:23 Jason W Knight 079 TOC SM 530 B A 05/05/6 22:8 James S Mathiot Moisture SM 2540 G A 05/05/6 9:47 Scott W Freisher *=This limit was used in the evaluation of the final result Page 3 of
114 Sample Description: D. Lacrosse Field #2 6"to2" Grab Soil Reeds Ferry Elementary School Project Name: SGPP - Merrimack Collected: 04/28/6 4:0 Submitted: 04/30/6 0:30 Reported: 09/28/6 08:30 DLF-2 CAT No. SDG#: SGP37-02 by LC CAS Number Result C. T. Male Associates 50 Century Hill Drive Latham NY Method Detection Limit* REVISED LL Sample # SW LL Group # Account # 379 Limit of Quantitation Misc. Organics EPA 537 Rev Perfluorobutanesulfonate U Perfluorodecanoic acid Perfluorododecanoic acid Perfluoroheptanoic acid U Perfluorohexanesulfonate U Perfluorohexanoic acid Perfluorononanoic acid Perfluoro-octanesulfonate Perfluorooctanoic acid Perfluorotetradecanoic acid J Perfluorotridecanoic acid U Perfluoroundecanoic acid J The stated QC limits are advisory only until sufficient data points can be obtained to calculate statistical limits. Wet Chemistry SM 530 B TOC n.a. 0, Wet Chemistry SM 2540 G Moisture n.a Moisture represents the loss in weight of the sample after oven drying at degrees Celsius. The moisture result reported is on an as-received basis. Dilution Factor Sample Comments All QC is compliant unless otherwise noted. Please refer to the Quality Control Summary for overall QC performance data and associated samples. Laboratory Sample Analysis Record CAT No. Method Trial# Batch# Analysis Date and Time Analyst Dilution Factor 4027 Full List PFC's EPA 537 Rev /4/6 :58 Marissa C Drexinger 4090 PFC Solid Prep EPA 537 Rev //6 8:23 Jason W Knight 079 TOC SM 530 B A 05/05/6 22:30 James S Mathiot Moisture SM 2540 G A 05/05/6 9:47 Scott W Freisher *=This limit was used in the evaluation of the final result Page 4 of
115 REVISED Quality Control Summary Client Name: C. T. Male Associates Reported: 09/28/6 08:30 Group Number: Matrix QC may not be reported if insufficient sample or site-specific QC samples were not submitted. In these situations, to demonstrate precision and accuracy at a batch level, a LCS/LCSD was performed, unless otherwise specified in the method. All Inorganic Initial Calibration and Continuing Calibration Blanks met acceptable method criteria unless otherwise noted on the Analysis Report. Method Blank Result MDL** LOQ Batch number: Sample number(s): Perfluorobutanesulfonate 0.50 U Perfluorodecanoic acid 0. U Perfluorododecanoic acid 0.40 U Perfluoroheptanoic acid 0.30 U Perfluorohexanesulfonate 0.50 U Perfluorohexanoic acid 0. U Perfluorononanoic acid 0. U Perfluoro-octanesulfonate 0.70 U Perfluorooctanoic acid 0.30 U Perfluorotetradecanoic acid 0.30 U Perfluorotridecanoic acid 0.60 U Perfluoroundecanoic acid 0.30 U Batch number: A Sample number(s): TOC 00 U LCS/LCSD LCS Spike LCS LCSD Spike LCSD Added Conc Added Conc LCS REC LCSD REC LCS/LCSD Limits RPD RPD Max Batch number: Sample number(s): Perfluorobutanesulfonate Perfluorodecanoic acid 9.5 Perfluorododecanoic acid 8 Perfluoroheptanoic acid.7 Perfluorohexanesulfonate Perfluorohexanoic acid 8.5 Perfluorononanoic acid.5 Perfluoro-octanesulfonate Perfluorooctanoic acid 5.7 Perfluorotetradecanoic acid 37.5 Perfluorotridecanoic acid 27.6 Perfluoroundecanoic acid * 38* Batch number: A Sample number(s): TOC *- Outside of specification **-This limit was used in the evaluation of the final result for the blank () The result for one or both determinations was less than five times the LOQ. (2) The unspiked result was more than four times the spike added. P###### is indicative of a Background or Unspiked sample that is batch matrix QC and was not performed using a sample from this submission group. Page 5 of
116 REVISED Quality Control Summary Client Name: C. T. Male Associates Reported: 09/28/6 08:30 Group Number: LCS/LCSD (continued) LCS Spike LCS LCSD Spike LCSD Added Conc Added Conc LCS REC LCSD REC LCS/LCSD Limits RPD RPD Max Batch number: A Sample number(s): Moisture MS/MSD Unspiked (UNSPK) = the sample used in conjunction with the matrix spike Unspiked Conc MS Spike Added MS Conc MSD Spike Added MSD Conc MS Rec MSD Rec MS/MSD Limits RPD RPD Max Batch number: Sample number(s): UNSPK: Perfluorobutanesulfonate 0.50 U Perfluorodecanoic acid 0. U Perfluorododecanoic acid 0.40 U Perfluoroheptanoic acid 0.30 U Perfluorohexanesulfonate 0.50 U Perfluorohexanoic acid 0. U Perfluorononanoic acid 0. U Perfluoro-octanesulfonate 0.70 U Perfluorooctanoic acid Perfluorotetradecanoic acid 0.30 U Perfluorotridecanoic acid 0.60 U Perfluoroundecanoic acid 0.30 U Batch number: A Sample number(s): UNSPK: P TOC Laboratory Duplicate Background (BKG) = the sample used in conjunction with the duplicate BKG Conc DUP Conc DUP RPD DUP RPD Max Batch number: A Sample number(s): BKG: P TOC * () 7 Batch number: A Sample number(s): BKG: P Moisture *- Outside of specification **-This limit was used in the evaluation of the final result for the blank () The result for one or both determinations was less than five times the LOQ. (2) The unspiked result was more than four times the spike added. P###### is indicative of a Background or Unspiked sample that is batch matrix QC and was not performed using a sample from this submission group. Page 6 of
117 REVISED Quality Control Summary Client Name: C. T. Male Associates Reported: 09/28/6 08:30 Group Number: *- Outside of specification **-This limit was used in the evaluation of the final result for the blank () The result for one or both determinations was less than five times the LOQ. (2) The unspiked result was more than four times the spike added. P###### is indicative of a Background or Unspiked sample that is batch matrix QC and was not performed using a sample from this submission group. Page 7 of
118 Page 8 of
119 Page 9 of
ANALYSIS REPORT. Report Date: February 16, :56. Project: SGPP - McCaffrey Street
ANALYSIS REPORT Prepared by: Eurofins Lancaster Laboratories Environmental 242 New Holland Pike Lancaster, PA 17601 Prepared for: C. T. Male Associates 0 Century Hill Drive Latham NY 12110 Report Date:
More informationANALYSIS REPORT. Report Date: April 27, :34. Project: Hoosick Falls WTP
REVISED ANALYSIS REPORT Prepared by: Eurofins Lancaster Laboratories Environmental 2425 New Holland Pike Lancaster, PA 17601 Prepared for: C. T. Male Associates 50 Century Hill Drive Latham NY 12110 Report
More informationDetermination of Selected ASTM Perfluorinated Compounds (PFCs) Using the Shimadzu LCMS No. LCMS-083. No. SSI-LCMS-083
Liquid Chromatography Mass Spectrometry No. LCMS-083 Determination of Selected ASTM Perfluorinated Compounds (PFCs) Using the Shimadzu LCMS-8060 Summary ASTM methods D7968-14 and D7979-15 are used to determine
More informationCity of Satellite Beach Per and Polyfluoroalkyl Substances (PFAS) Water Sampling Satellite Beach, Florida
August 2, 2018 Mr. Nicholas Frank Sanzone Environmental Programs Coordinator 565 Cassia Boulevard Satellite Beach, FL 32937 nsanzone@satellitebeach.org Subject: City of Satellite Beach Per and Polyfluoroalkyl
More informationThe Analysis of Per (poly) Fluorinated Compounds Beyond UCMR3
The Analysis of Per (poly) Fluorinated Compounds Beyond UCMR3 Chuck Neslund, Technical Director, Eurofins Lancaster Laboratories Environmental, LLC NEMC, Orange County, CA August 8-12, 2016 Providing comprehensive
More informationPROJECT ID: AP0220 LABORATORY REPORT NUMBER: L PO NUMBER:
Serialized: 04/18/2017 03:20pm QC21 JOHN SWANSON PEMBERTON TOWNSHIP PUBLIC SCHOOLS PO BOX 228 ONE EGBERT STREET PEMBERTON,NJ 08068 Regarding: PEMBERTON TOWNSHIP PUBLIC SCHOOLS ONE EGBERT STREET PEMBERTON,
More informationBenetton PFCs investigation report December 2015
Benetton Group Commitment As part of its zero discharges pledge, Benetton Group (Benetton) is committed to completely eliminating Per-Fluorinated Chemicals (PFCs) from all its products and processes. What
More informationMethod Code: NH0278 Method Ref: SOP 454-PFAAS-ISOTOPE DILUTION Revision: Date:
Analyte Code Analyte Name Effective Date Expiration Date Matrix Category Accr. Type Method Code: 10091675 Method Ref: EPA 537 Revision: 1.1 Date: 2009 6911 PERFLUOROBUTANE SULFONATE (PFBS) 04/26/2017 09/06/2019
More informationIf you have any questions concerning this report, please feel free to contact me. REPORT OF LABORATORY ANALYSIS
#=CL# Pace Analytical Services, LLC 9608 Loiret Blvd. Lenexa, KS 66219 (913)599-5665 LIMS USE: FR - JAMES BOSTON LIMS OBJECT ID: 60252907 September 28, 2017 Mr. James Boston City of Decatur PO Box 247
More informationSampling & Analytical Considerations. Jim Occhialini Alpha Analytical
Sampling & Analytical Considerations Jim Occhialini Alpha Analytical Standard analytical technical challenges: High sensitivity required, potential for cross contamination MOVING TARGET Analytical methodologies
More informationBrick Utilities PFOA Source Trackdown Study
Brick Utilities PFOA Source Trackdown Study NJ Water Monitoring Council January 21, 2016 Robert Karl Source Water Supervisor Acknowledgements Project funded by grant from NJDEP NJDEP Office of Science
More informationMay 31, Mr. Thomas Touseau SAU 26, Merrimack School District Facilities Director Facilities Management 36 McElwain Street Merrimack, NH 03154
May 31, 2016 Mr. Thomas Touseau SAU 26, Merrimack School District Facilities Director Facilities Management 36 McElwain Street Merrimack, NH 03154 Re: Reeds Ferry School Limited Soil Testing RPF Project
More informationOccurrence of perfluoroalkyl compounds in surface waters from the North Pacific to the Arctic Ocean
Supporting Information Occurrence of perfluoroalkyl compounds in surface waters from the North Pacific to the Arctic Ocean Minghong Cai 1, 2,* Zhen Zhao 3, Zhigao Yin 2, Lutz Ahrens 3,4, Peng Huang 5,
More informationMaine Department of Environmental Protection (MEDEP) Stone Farm, Arundel Sample Collection - Data Report Summary Report Date: June 15, 2017
Maine Department of Environmental Protection (MEDEP) Stone Farm, Arundel Sample Collection - Data Report Summary Report Date: June 15, 2017 --------------------------------------------------------------------------------------------------------------------------
More informationTREATMENT MITIGATION STRATEGIES FOR POLY- AND PERFLUOROALKYL CHEMICALS. December 14, Objective
TREATMENT MITIGATION STRATEGIES FOR POLY- AND PERFLUOROALKYL CHEMICALS Eric Dickenson, Ph.D. R&D Project Manager December 14, 2016 Objective Evaluate the ability of a wide spectrum of full-scale drinking
More informationTRACE LEVEL DETERMINATION OF PER- AND POLYFLUOROALKYL SUBSTANCES (PFASs) IN WATER USING THE AGILENT 6460 LC/MS/MS
ENVIRONMENTAL MARKET TRACE LEVEL DETERMINATION OF PER- AND POLYFLUOROALKYL SUBSTANCES (PFASs) IN WATER USING THE AGILENT 6460 LC/MS/MS A method for the determination of per- and polyfluoroalkyl substances
More informationPFOS, PFOA and Other Fluorinated Compounds: Sampling and Analy<cal Challenges
PFOS, PFOA and Other Fluorinated Compounds: Overcoming Sampling and Analy
More informationBenetton Group srl PFCs Elimination Progress
Benetton Group srl PFCs Elimination Progress 1 Index Introduction, scope and purpose... 3 Foreword, Concept and Background... 3 What are PFCs?... 3 Difference between long- and short-chain PFCs... 3 Benetton
More informationPerfluorinated compounds in marine surface waters: data from the Baltic Sea and methodological challenges for future studies
Accessory publication Perfluorinated compounds in marine surface waters: data from the Baltic Sea and methodological challenges for future studies Torben Kirchgeorg, A,B Ingo Weinberg, A Annekatrin Dreyer
More informationAutomated Low Background Solid Phase Extraction of Perfluorinated Compounds in Water. Ruud Addink Fluid Management Systems Watertown MA
Automated Low Background Solid Phase Extraction of Perfluorinated Compounds in Water Ruud Addink Fluid Management Systems Watertown MA Introduction Perfluoralkylated compounds contain a perfluorinated
More informationFINAL SITE INSPECTION REPORT PATRICK AIR FORCE BASE, FL
FIL SITE INSPECTION REPORT PATRICK AIR FORCE BASE, FL Site Inspection of Aqueous Film Forming Foam (AFFF) Release Areas Environmental Programs Worldwide Contract FA8903-16-D-0027 Task Order 0004 December
More informationCase Study Phase out of Perfluorinated Compounds (PFCs) H&M Group April 2017
Case Study Phase out of Perfluorinated Compounds (PFCs) H&M Group April 2017 1 Introduction Perflourinated Compounds (PFCs) are a group of substances, commonly used to make outerwear more resistant to
More informationPerfluorinated Compounds Treatment and Removal
Treatment and Removal What are PFCs? The presence of perfluorinated compounds (PFCs) in source waters and drinking water is of growing concern to water professionals. This group of organic compounds, used
More informationASTM WK Standard Test Method for Dissolved Gases. Anne Jurek Applications Chemist
ASTM WK 43267 Standard Test Method for Dissolved Gases Anne Jurek Applications Chemist Rationale Hydraulic Fracturing is becoming more and more common. Nearby water well can be affected during the fracking
More informationQuality Assurance Charting for QC Data
Quality Assurance Charting for QC Data September 2018 Iowa s Environmental & Public Health Laboratory Copyright the State Hygienic Laboratory at the University of Iowa 2017. All rights reserved. Images
More informationASSESSMENT OF HEALTH RISKS AND HUMAN EXPOSURE ASSOCIATED WITH PERFLUORINATED COMPOUNDS (PFCs) IN TAP WATER FROM CHINA AND OTHER COUNTRIES
ASSESSMENT OF HEALTH RISKS AND HUMAN EXPOSURE ASSOCIATED WITH PERFLUORINATED COMPOUNDS (PFCs) IN TAP WATER FROM CHINA AND OTHER COUNTRIES MAK YIM LING MASTER OF PHILOSOPHY CITY UNIVERSITY OF HONG KONG
More informationPerfluorinated Compounds Prevalence and Assessment in Drinking Water
Prevalence and Assessment in Drinking Water What are PFCs? Perfluorinated Compounds (PFCs), also referred to as perfluorinated alkyl substances (PFASs), are a large group of environmentally persistent
More informationSupporting Information. (32 Pages) Bioconcentration of aqueous film-forming foam (AFFF) in juvenile rainbow. trout (Oncorhyncus mykiss)
1 2 Supporting Information (32 Pages) 3 4 5 Bioconcentration of aqueous film-forming foam (AFFF) in juvenile rainbow trout (Oncorhyncus mykiss) 6 7 8 Leo W.Y. Yeung and Scott A. Mabury * 9 10 11 Department
More informationPFCs/PFAS: Emerging Environmental Contaminants & NJDEP Update
PFCs/PFAS: Emerging Environmental Contaminants & NJDEP Update Gloria B. Post, Ph.D., D.A.B.T. Division of Science, Research & Environmental Health New Jersey Department of Environmental Protection NCNJ
More informationIntroduction. Experimental
PO-CON162E Development of Automated Screening and Quantitation Approach on Novel On-Line SFE-SFC-MS/MS Platform (I) For 23 Restricted Perflurocompounds in Textiles ASMS 2016 MP 283 Jie Xing, Jun Xiang
More informationN Korea Japan China Thailand Taiwan Philipines EP-5 EP km. Source: Google Maps and
OCCURRENCES AND TRANSPORT OF PERFLUORINATED COMPOUNDS IN EAST CHINA SEA Kunacheva C 1, Fujii S 1, Tanaka S 1, Shimizu J 2 and Shivakoti B R 1 1 Graduate School of Global Environmental Studies, Kyoto University,
More informationAutomated Determination of Dissolved Gases in Water Anne Jurek. Abstract: Discussion:
Automated Determination of Dissolved Gases in Water Anne Jurek Abstract: The RSK-175 standard operating procedure was developed in order to determine the amount of dissolved gas in water. Due to the expansion
More informationRiver Water Intake Collected: 20 June WW Loading Collected: 20 June 2018
Analyte CAS No Unit 537 (modified) PFAS HFPO DA 13252 13 6 µg/l 0.0093 3,600 2,900 1,300 F1 J Table 3 SOP PEPA N/A µg/l
More informationQuality Assurance/Quality Control (QA/QC) Summary for Year 1 of the California Coast Survey
APPENDIX 1 Quality Assurance/Quality Control (QA/QC) Summary for Year 1 of the California Coast Survey APPENDIX 1 Quality Assurance/Quality Control (QA/QC) Summary for Year 1 of the California Coast Survey
More informationCommercial Practice Test Method Internal Vapor Analysis of Hermetic Devices
Commercial Practice Test Method Internal Vapor Analysis of Hermetic Devices Oneida Research Services, Inc. 8282 Halsey Road Whitesboro, NY 13492 Phone: (315) 736-5480 FAX: (315) 736-9321 1.0 Purpose The
More informationSTD-3-V1M4_1.7.1_AND_ /15/2015 page 1 of 6. TNI Standard. EL-V1M4 Sections and September 2015
page 1 of 6 TNI Standard EL-V1M4 Sections 1.7.1 and 1.7.2 September 2015 Description This TNI Standard has been taken through all of the voting stages and has received consensus approval by the TNI membership.
More informationControls and Control Charting
Controls and Control Charting Control Charts and Trend Analysis for ISO/IEC 17025:2005 www.aphl.org Abbreviation and Acronyms CRM-Certified Reference Materials RM-Reference Materials PT-Proficiency Test(ing)
More informationIndustrial Hygiene Sampling. Husqvarna Construction Products
! Report of: Industrial Hygiene Sampling Husqvarna Construction Products Olathe, KS Palmetto EHS Report No: 2017039 Rev. 1 Submitted Prepared for: Husqvarna Construction Products Prepared By: Palmetto
More informationAddendum 1 Lab Testing Services April 4, 2018
TO ALL BIDDERS: Addendum Lab Testing Services April 4, 208 Below are changes and or clarifications to the proposal documents for this project. This Addendum forms a part of the Contract Documents and modifies
More informationRADON SCREENING SURVEY FOLLOW-UP MONTGOMERY VILLAGE MIDDLE SCHOOL Watkins Mill Road, Montgomery Village, Maryland 20886
RADON SCREENING SURVEY FOLLOW-UP MONTGOMERY VILLAGE MIDDLE SCHOOL 19300 Watkins Mill Road, Montgomery Village, Maryland 20886 EXECUTIVE SUMMARY Date of Test Report: 3/24/16 Follow-Up Round of Testing:
More informationPerfluorerade organiska ämnen i serum från förstföderskor i Uppsala tidstrend
Sakrapport till Naturvårdsverkets Miljöövervakning: Perfluorerade organiska ämnen i serum från förstföderskor i Uppsala tidstrend 1996-21 Avtalsnr: 215 96 Utförare: Livsmedelsverket Programområde: Hälsorelaterad
More informationThis standard is due for Five Year Review. This process is required by the SEMI Regulations to ensure that the standard is still valid.
Background Statement for SEMI Draft Document 5211 REVISION OF SEMI C3.58-0303 SPECIFICATION FOR OCTAFLUOROCYCLOBUTANE, C 4 F 8, ELECTRONIC GRADE IN CYLINDERS, 99.999% QUALITY Note: This background statement
More informationMETHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER
1250 METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER 1.0 Scope and Application. 1.1 Analytes. Analyte CAS No. Sensitivity Total Organic Compounds N/A
More informationAutomated Determination of Dissolved Gases in Water By Headspace Calibration of Mixed Gases Anne Jurek
Automated Determination of Dissolved Gases in Water By Headspace Calibration of Mixed Gases Anne Jurek Abstract: Due to the expansion of natural gas drilling through horizontal fracturing, there has been
More informationRADON SCREENING SURVEY FOLLOW-UP RADNOR CENTER Radnor Road, Bethesda, Maryland 20817
RADON SCREENING SURVEY FOLLOW-UP RADNOR CENTER 7000 Radnor Road, Bethesda, Maryland 20817 EXECUTIVE SUMMARY Date of Test Report: 3/25/16 Follow-Up Round of Testing: Initial Follow-up Post Remediation #
More informationSITE TESTING STANDARDS FOR METHANE
INFORMATION BULLETIN / PUBLIC - BUILDING CODE REFERENCE NO.: 91.7104.1 Effective: 11-30-04 DOCUMENT NO. P/BC 2002-101 Revised: Previously Issued As: None SITE TESTING STANDARDS FOR METHANE This Infmation
More informationPFC Analysis Kit for ACQUITY UPLC System Guide
PFC Analysis Kit for ACQUITY UPLC System Guide 71500183002/Revision A Copyright Waters Corporation 2009 All rights reserved Copyright notice 2009 WATERS CORPORATION. PRINTED IN THE UNITED STATES OF AMERICA
More informationAutomated Determination of Dissolved Gases in Water Anne Jurek
Automated Determination of Dissolved Gases in Water Anne Jurek Abstract: Tapping the natural gas reservoirs throughout the United States has long been a viable solution for energy independence; however
More informationTotal Suspended Solids, Stable Flow, and Wet Weather Event Monitoring in the Bass River Watershed. December The Cadmus Group, Inc.
Total Suspended Solids, Stable Flow, and Wet Weather Event Monitoring in the Bass River Watershed December 2004 The Cadmus Group, Inc. Grand Valley State University Annis Water Resources Institute Submitted
More informationTotal Suspended Solids, Stable Flow, and Wet Weather Event Monitoring in the Unnamed Tributary to the Grand River Watershed.
Total Suspended Solids, Stable Flow, and Wet Weather Event Monitoring in the Unnamed Tributary to the Grand River Watershed December 2004 The Cadmus Group, Inc. Grand Valley State University Annis Water
More informationPerfluorinated Compounds (PFCs) Perfluorooctanoic Acid (PFOA) Perfluorooctane Sulfonate (PFOS) Focus On Change 2017
Perfluorooctanoic Acid (PFOA) Perfluorooctane Sulfonate (PFOS) Focus On Change 2017 Overview Background, Health, & Environmental Concerns Status of PFC Regulation Common Uses Regulatory Information Treatment
More informationLaboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.
Laboratory Hardware Custom Gas Chromatography Solutions Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION Laboratory Hardware Wasson-ECE Instrumentation offers hardware-only solutions
More informationSTANDARD OPERATING PROCEDURES
PAGE: 1 of 14 CONTENTS 1.0 SCOPE AND APPLICATION 2.0 METHOD SUMMARY 3.0 SAMPLE PRESERVATION, CONTAINERS, HANDLING, AND STORAGE 4.0 INTERFERENCES AND POTENTIAL PROBLEMS 5.0 EQUIPMENT/APPARATUS 5.1 Subatmospheric
More informationPlexiglas (R) SG PLUS Impact Acrylic Sheet Material Safety Data Sheet
1 PRODUCT AND COMPANY IDENTIFICATION Altuglas International 2000 Market Street Philadelphia, PA 19103 Information Telephone Numbers Altuglas International Customer Service EMERGENCY PHONE NUMBERS: Chemtrec:
More informationMETHOD 3A - DETERMINATION OF OXYGEN AND CARBON DIOXIDE CONCENTRATIONS IN EMISSIONS FROM STATIONARY SOURCES (INSTRUMENTAL ANALYZER PROCEDURE)
METHOD 3A - DETERMINATION OF OXYGEN AND CARBON DIOXIDE CONCENTRATIONS IN EMISSIONS FROM STATIONARY SOURCES (INSTRUMENTAL ANALYZER PROCEDURE) 1.0 Scope and Application What is Method 3A? Method 3A is a
More informationAgilent Dimension Software for ELSD User Manual
Agilent Dimension Software for ELSD User Manual Agilent Dimension Software for ELSD User Manual Agilent Technologies Notices Agilent Technologies, Inc. 2011 No part of this manual may be reproduced in
More informationNUTC R285. Effect of Trona on the Leaching of Trace Elements from Coal Fly Ash. Jianmin Wang, Ph.D., P.E. Honglan Shi, Ph.D.
Effect of Trona on the Leaching of Trace Elements from Coal Fly Ash by Jianmin Wang, Ph.D., P.E. Honglan Shi, Ph.D. NUTC R285 A National University Transportation Center at Missouri University of Science
More informationThe ABCs of PFCs in Water Supplies
Subscribe to HDR Publications WATER SUPPLY The ABCs of PFCs in Water Supplies By Christina Alito, PE, PhD, ENV SP Water/Wastewater Engineer, Vienna, VA, and Pierre Kwan, PE Senior Project Manager, Seattle,
More informationAgilent 490 Micro GC Natural Gas Analyzer
Agilent 490 Micro GC Natural Gas Analyzer User Manual Agilent Technologies Notices Agilent Technologies, Inc. 2012 No part of this manual may be reproduced in any form or by any means (including electronic
More informationRADON SCREENING SURVEY FOLLOW-UP GEORGIAN FOREST ELEMENTARY SCHOOL Regina Drive, Silver Spring, Maryland 20906
RADON SCREENING SURVEY FOLLOW-UP GEORGIAN FOREST ELEMENTARY SCHOOL 3100 Regina Drive, Silver Spring, Maryland 20906 EXECUTIVE SUMMARY Date of Test Report: 3/4/16 Follow-Up Round of Testing: Initial Follow-up
More informationControl Charting: Lessons Learned Along the Way Why, What, and How
Control Charting: Lessons Learned Along the Way Why, What, and How Stacie Hammack Florida Department of Agriculture and Consumer Services Food Laboratories Why? Because it is required: ISO/IEC 17025 section
More informationClass 1 (Explosive) Hazmat: The Hazardous Materials Table. Hazard Classifications Used in Hazmat Table, Column 3
Hazard Classifications Used in Hazmat Table, Column 3 Class Number None None Division Number (if any) Name of class or division... Forbidden Material... Forbidden Explosives Class 1 (Explosive) Known hazards
More informationMCPS RADON TESTING. Executive Summary: College Gardens Elementary School
E N G I N E E R S P L A N N E R S S C I E N T I S T S C O N S T R U C T I O N M A N A G E R S 936 RIDGEBROOK ROAD SPARKS, MD 21152 410-316-7800 (FAX) 410-316-7935 MCPS RADON TESTING Executive Summary:
More informationSupersedes: The copy of this document located on Measurement Canada s website is considered to be the controlled copy.
Bulletin Category: GAS Bulletin: G-23 Page: 1 of 7 The copy of this document located on Measurement Canada s website is considered to be the controlled copy. Recognition of data from specialty gas suppliers
More informationMSD 96-Well MULTI-ARRAY and MULTI-SPOT Human Granulocyte Colony Stimulating Factor (hg-csf) Ultrasensitive Assay
MSD 96-Well MULTI-ARRAY and MULTI-SPOT Human Granulocyte Colony Stimulating Factor (hg-csf) Ultrasensitive Assay Summary This assay measures Human Granulocyte Colony Stimulating Factor (G-CSF) in a 96-well
More informationSEMLATA3-12 Measuring, weighing and preparing compounds and solutions for laboratory use
Measuring, weighing and preparing compounds and solutions for Overview This unit covers the competences you need to measure, weigh and prepare compounds and solutions for laboratory investigations. Prior
More informationIngredient CAS Number Weight % ACGIH TLV PEL STEL Calcium Hypochlorite % Not Established Not Established
Page 1 of 5 MSDS Document Product 1. Chemical Product and Company Identification Product Manufacturer Haviland Consumer Products, Inc. 421 Ann Street N.W. Grand Rapids, MI 49504 Phone Number (616) 361-6691
More informationANALOG ULTRASOUND WATTMETER USP-30
ANALOG ULTRASOUND WATTMETER USP-30 USER MANUAL BC BIOMEDICAL USP-30 ULTRASOUND WATTMETER TABLE OF CONTENTS WARNINGS, CAUTIONS, NOTICES... ii DESCRIPTION... 1 TEST SETUP... 2 TESTING... 5 MANUAL REVISIONS...
More informationMETHOD 21 - DETERMINATION OF VOLATILE ORGANIC COMPOUND LEAKS. 1.2 Scope. This method is applicable for the
1151 METHOD 21 - DETERMINATION OF VOLATILE ORGANIC COMPOUND LEAKS 1.0 Scope and Application. 1.1 Analytes. Analyte Volatile Organic Compounds (VOC) CAS No. No CAS number assigned 1.2 Scope. This method
More informationDOD Hazardous Material Information (ANSI Format) For Cornell University Convenience Only
Division of Facilities Services DOD Hazardous Material Information (ANSI Format) For Cornell University Convenience Only Section 1 - Product and Company Identification Section 2 - Compositon/Information
More informationMCPS RADON TESTING. Executive Summary: Poolesville Elementary School
E N G I N E E R S P L A N N E R S S C I E N T I S T S C O N S T R U C T I O N M A N A G E R S 936 RIDGEBROOK ROAD SPARKS, MD 21152 410-316-7800 (FAX) 410-316-7935 MCPS RADON TESTING Executive Summary:
More informationIntegrity Testing LifeASSURE BNA045 and BNA065 Series Filter Cartridges
Integrity Testing LifeASSURE BNA045 and BNA065 Series Filter Cartridges SAFETY INFORMATION Read, understand, and follow all safety information contained in these instructions and the instructions provided
More informationExhibit 4. Determination of Static Pressure Performance of the Healy Clean Air Separator (Executive Orders VR-201-N and VR-202-N)
1 APPLICABILITY Exhibit 4 Determination of Static Pressure Performance of the Healy Clean Air Separator (Executive Orders VR-201-N and VR-202-N) Definitions common to all certification and test procedures
More informationMATERIAL SAFETY DATA SHEET 3M Tempa-DOT Thermometers (without latex in overwrap) 03/27/09
Material Safety Data Sheet Copyright, 2009, 3M Company. All rights reserved. Copying and/or downloading of this information for the purpose of properly utilizing 3M products is allowed provided that: (1)
More informationSTANDARD OPERATING PROCEDURES
PAGE: 1 of 14 CONTENTS 1.0 SCOPE AND APPLICATION 2.0 METHOD SUMMARY 3.0 SAMPLE PRESERVATION, CONTAINERS, HANDLING AND STORAGE 4.0 INTERFERENCE AND POTENTIAL PROBLEMS 5.0 EQUIPMENT/APPARATUS 6.0 REAGENTS
More informationNATIONAL COMMISSION FOR THE CERTIFICATION OF CRANE OPERATORS (NCCCO) LIFT DIRECTOR TOWER CRANES LOAD CHART MANUAL
NATIONAL COMMISSION FOR THE CERTIFICATION OF CRANE OPERATORS (NCCCO) LIFT DIRECTOR TOWER CRANES LOAD CHART MANUAL HAMMERHEAD TOWER CRANE CHART D LUFFING BOOM TOWER CRANE CHART F These charts have been
More informationIowa Exceedances of the National Ambient Air Quality Standards, 2013 (Reported Through October 8 th ) Iowa DNR Ambient Air Monitoring Group
Iowa Exceedances of the National Ambient Air Quality Standards, 2013 (Reported Through October 8 th ) Iowa DNR Ambient Air Monitoring Group What Are the NAAQS? The Clean Air Act requires EPA to set National
More informationLDO II AQ 2/2014, Edition 1.5
9623800 LDO II AQ 2/2014, Edition 1.5 USER MANUAL Table of Contents Specifications on page 2 General information on page 3 Product overview on page 4 Installation on page 5 Operation on page 7 Maintenance
More informationGCMSD-Headspace Analysis SOP
Before you start GCMSD-Headspace Analysis SOP Method and Sequences names are restricted to 50 characters (MSD program will crash otherwise) The GC oven and Injection Ports need to be cooled to 50 oc to
More informationMaterial Safety Data Sheet
Material Safety Data Sheet Section 1 General Information Manufacturer: Zinsser Company, Inc. 173 Belmont Drive Somerset, NJ 08875 (732) 469-8100 Emergency Telephone: Chemtrec (800) 424-9300 Date: January
More informationModel B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data
Technical Services: Tel: (800) 381-312 / Fax: (800) 71-5500 Customer Service/Sales: Tel: (215) 362-0700 / (800) 523-6512 Fax: (215) 362-5385 Model B-1 Pipe Line Strainer 3,, 6 & 8 Inch (DN80, DN100, DN150
More informationLaboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.
Laboratory Hardware Custom Gas Chromatography Solutions Custom solutions for your analytical needs. Laboratory Hardware Wasson-ECE Instrumentation offers hardware-only solutions for advanced chromatography
More informationLab 1. Instrumentation Familiarity: Using Micropipetters and Serological Pipettes
Instrumentation Familiarity: Using Micropipetters and Serological Pipettes Introduction: In molecular biology we sometimes need to measure volumes as small as one millionth of a liter (a liter is about
More informationASDX Series Silicon Pressure Sensors
ASDX Series Silicon Pressure Sensors DESCRIPTION The ASDX Series is a Silicon Pressure Sensor offering a ratiometric analog interface for reading pressure over the specified full scale pressure span and
More informationMCPS RADON TESTING. Executive Summary: Pine Crest Elementary School
E NGINEERS P LANNERS S CIENTISTS C ONSTRUCTION M ANAGERS 936 RIDGEBROOK ROAD SPARKS, MD 21152 410-316-7800 (FAX) 410-316-7935 MCPS RADON TESTING Executive Summary: Pine Crest Elementary School Date of
More informationMILITARY SPECIFICATION POWDER, BLACK
INCH-POUND 2 October 1998 SUPERSEDING AMENDMENT 1 10 June 1997 MILITARY SPECIFICATION POWDER, BLACK This Amendment forms a part of Military Specification dated 5 February 1993, and is approved for use
More informationHenkel Corporation 710 Ohio Street Buffalo, NY Attn: Plant Manager/Director Safety HENKEL CORPORATION UBFCSLAL BUFFALO NY /16/06
Henkel Corporation 710 Ohio Street Buffalo, NY 14203 Attn: Plant Manager/Director Safety HENKEL CORPORATION UBFCSLAL BUFFALO NY 14203 10/16/06 Dear Customer: The enclosed Material Safety Data Sheet (MSDS)
More informationWaterSense Specification for Spray Sprinkler Bodies. Version 1.0
Version 1.0 September 21, 2017 WaterSense Specification for Spray Sprinkler Bodies 1.0 Scope and Objective This specification establishes the criteria for labeling bodies of spray sprinklers 1 under the
More informationMATERIAL SAFETY DATA SHEET
SECTION 1: PRODUCT AND COMPANY IDENTIFICATION PRODUCT NAME: G96 MILITARY GRADE BORE SOLVENT PRODUCT CODES: G96 Part Numbers: #1107, #1108 MANUFACTURER: G96 Products Inc. ADDRESS: 85 5 th Ave, Bldg #6 Paterson,
More informationMaterial Safety Data Sheet
Material Safety Data Sheet Section 1 General Information Manufacturer: Rust-Oleum Corporation 11 Hawthorn Parkway Vernon Hills, IL 60061 24 Hour Assistance: 1-847-367-7700 www.rustoleum.com Date: April
More informationMaterial Safety Data Sheet (ATTAR-C)
Janes Industrial Products, LLC PO Box 81282 Lafayette, LA 70598 (337) 269-6306 Material Safety Data Sheet HMIS HEALTH:...1 HMIS FLAMMABILITY:...0 HMIS REACTIVITY:...0 PERSONAL PROTECTION:...B EMERGENCY
More informationMaterial Safety Data Sheet
Material Safety Data Sheet Section 1 General Information Manufacturer: Zinsser Company, Inc. 173 Belmont Drive Somerset, NJ 08875 (732) 469-8100 Emergency Telephone: Chemtrec (800) 424-9300 Date: April
More informationIngredient CAS Number Weight % ACGIH TLV PEL STEL Phosphoric Acid mg/m3 1 mg/m3 3 mg/m3
Page 1 of 5 MSDS Document Product 1. Chemical Product and Company Identification Trade Name of this Product Manufacturer Haviland Consumer Products, Inc. 421 Ann Street N.W. Grand Rapids, MI 49504 Phone
More informationU S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.
U S E R M A N U A L 1600 SERIES OXYGEN REGULATOR 168715G (Shown) SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician. 300 Held Drive Tel: (+001) 610-262-6090
More informationMCPS RADON TESTING. Executive Summary: Olney Elementary School
E N G I N E E R S P L A N N E R S S C I E N T I S T S C O N S T R U C T I O N M A N A G E R S 936 RIDGEBROOK ROAD SPARKS, MD 21152 410-316-7800 (FAX) 410-316-7935 MCPS RADON TESTING Executive Summary:
More informationReal World Metric System
Real World Metric System Learning Objectives 1. Identify the metric units of weight, length, volume and temperature. 2. Make measurements using the metric system. 3. Convert values between different metric
More informationRapid and Reliable Detection of Dissolved Gases in Water
Rapid and Reliable Detection of Dissolved Gases in Water Andrea Caruso and Massimo Santoro Thermo Fisher Scientific, Milan, Italy Application Note 005 Key Words Chromeleon CDS, Environmental, Fracking,
More informationPROTOCOL FOR COMPRESSED AIR PROFICIENCY TESTING (CAPT) PROGRAM SAMPLE ANALYSIS
Contact Information: PROTOCOL FOR COMPRESSED AIR PROFICIENCY TESTING (CAPT) PROGRAM SAMPLE ANALYSIS No formal enrollment is required to participate in the CAPT program. To get added to the email notifications
More informationTape, Polyester Two Sided Pressure Sensitive. Technical Bulletin August, 2016
Ford ESB-M3G76-B2 Tape, Polyester Two Sided Pressure Sensitive Automotive Spec Testing Technical Bulletin August, 2016 3M tested the following adhesive tapes to the Automotive OEM Spec: Ford ESB-M3G76-B2
More informationPsyclone TM. Protimeter Thermo-Hygrometer. GE Sensing. Operating Manual. INS7800, Rev. A (September 2007)
GE Sensing Psyclone TM Protimeter Thermo-Hygrometer Operating Manual INS7800, Rev. A (September 2007) Psyclone is a Protimeter product. Protimeter has joined other GE high-technology sensing businesses
More information