MANUAL: EF1 RC MONITOR

Size: px
Start display at page:

Download "MANUAL: EF1 RC MONITOR"

Transcription

1 MANUAL: EF1 RC MONITOR INSTRUCTIONS FOR INSTALLATION, SAFE OPERATION AND MAINTENANCE DANGER Understand manual and documents in additional literature before use. Operation of this device without understanding the manual and receiving proper training is a misuse of this equipment. Obtain safety information at com/serial-number This instruction manual is intended to familiarize firefighters and maintenance personnel with the operation, servicing and safety procedures associated with the EF1 RC Monitor series. This manual should be kept available to all operating and maintenance personnel. See Section for Flow/Pressure Operating Envelope ef1 rc MADE IN USA MODEL# SERIAL# Y1165 TASK FORCE TIPS, INC. MADE IN USA Innovation Way, Valparaiso, IN USA Fax

2 DANGER PERSONAL RESPONSIBILITY CODE The member companies of FEMSA that provide emergency response equipment and services want responders to know and understand the following: 1. Firefighting and Emergency Response are inherently dangerous activities requiring proper training in their hazards and the use of extreme caution at all times. 2. It is your responsibility to read and understand any user s instructions, including purpose and limitations, provided with any piece of equipment you may be called upon to use. 3. It is your responsibility to know that you have been properly trained in Firefighting and /or Emergency Response and in the use, precautions, and care of any equipment you may be called upon to use. 4. It is your responsibility to be in proper physical condition and to maintain the personal skill level required to operate any equipment you may be called upon to use. 5. It is your responsibility to know that your equipment is in operable condition and has been maintained in accordance with the manufacturer s instructions. 6. Failure to follow these guidelines may result in death, burns or other severe injury. Fire and Emergency Manufactures and Service Association P.O. Box 147, Lynnfield, MA FEMSA ADDITIONAL MANUALS MANUAL: Remote Control (RC) Monitor Electrical Controls Supplemental Instructions for use with RC Monitor Manual INSTRUCTIONS FOR INSTALLATION, SAFE OPERATION AND MAINTENANCE DANGER Understand manual before use. Operation of this device without understanding the manual and receiving proper training is a misuse of this equipment. Obtain safety information at com/serial-number SECTION 3.0 SECTION 4.9 General Information and Specifications SECTION 4.0 Electrical Controls Installation and Operation SECTION 4.1 Monitor Mounted Operator Station SECTION 4.2 Panel Mount Operator Station (Y4E-RP) SECTION 4.3 Panel Mount With Display Operator Station (Y4E-RP-D) SECTION 4.4 Tethered Operator Station (Y4E-CT-##) SECTION 4.5 Tethered Operator Station With Display (Y4E-CT-##-D) SECTION 4.6 Wireless Operator Station (YE-RF-##) SECTION 4.7 Wireless Operator Station With Display (YE-RF-##-D) SECTION 4.8 Joystick Operator Station (Y4E-JS) TASK FORCE TIPS, INC. MADE IN USA Toggle Switch Monitor Operator Station (Y4E-TS) SECTION 4.10 Monitor Communication Interface Control (Y4E-COMM) SECTION 4.11 Monitor Position Display (Y4E-DISP) SECTION 4.12 Remote Auxiliary Function Interface Control (YE-REMAUX) SECTION 4.13 Electric RC Monitor Aerial Truck Installation SECTION 4.14 Multiplex Interface Control (YE-CAN#) SECTION 4.15 Ethernet Interface Control SECTION 4.16 Electric Nozzle Actuator SECTION 4.17 Valve Kits (YE-VK-PH) SECTION 5.0 Troubleshooting 3701 Innovation Way, IN USA Fax Copyright Task Force Tips, Inc LIY-500 May 31, 2016 Rev11 MANUAL: Remote Control (RC) Monitor Electrical Controls LIY-500 2

3 Table Of Contents 1.0 MEANING OF SAFETY SIGNAL WORDS 2.0 SAFETY 3.0 GENERAL INFORMATION 3.1 PART IDENTIFICATION 3.2 SPECIFICATIONS MECHANICAL SAFE OPERATING ENVELOPE 3.3 USE WITH SALT WATER 3.4 INLETS AND OUTLET OPTIONS 3.5 OVERALL DIMENSIONS 4.0 INSTALLATION 4.1 STRUCTURAL REQUIREMENTS 4.2 TRAVEL RANGES TRAVEL STOPS 4.3 NOZZLE INSTALLATION 4.4 PRESSURE GAGE 4.5 DRAINING RESIDUAL WATER 5.0 SPRAY TRAJECTORY ADJUSTMENT 6.0 OPERATION OF RC MONITORS 7.0 RECOMMENDED PARK POSITION 7.1 OVERRIDE HEX DRIVE 8.0 CHARACTERISTICS 8.1 STACKED TIPS 8.2 EF1 RC MONITOR FRICTION LOSS 9.0 DRAWINGS AND PARTS LIST 10.0 WARRANTY 11.0 MAINTENANCE 11.1 LUBRICATION 11.2 TROUBLESHOOTING 11.3 REPAIR 12.0 ANSWERS TO YOUR QUESTIONS 13.0 INSPECTION CHECKLIST 3

4 1.0 MEANING OF SAFETY SIGNAL WORDS A safety related message is identified by a safety alert symbol and a signal word to indicate the level of risk involved with a particular hazard. Per ANSI standard Z , the definitions of the four signal words are as follows: DANGER DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. indicates a hazardous situation which, if not avoided, could result in death or serious injury. indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE NOTICE is used to address practices not related to physical injury. 2.0 SAFETY The operation of this monitor can be dangerous. The following must be observed at all times. An inadequate supply of nozzle pressure and/or flow will cause an ineffective stream and can result in injury, death, or loss of property. See flow graphs or call for assistance. Injury or death may occur by attempting to use a damaged monitor. Before using the monitor, inspect it for damage resulting from, but not limited to: Failure to drain monitor followed by exposure to freezing conditions. See section DRAINING RESIDUAL WATER for instructions. Exposure of monitor to temperatures in excess of 160 F (71 C). Missing parts, physical abuse, exposure to severe chemicals. Deformed or cracked flanges damaged as a result of improper installation. - Excessive bolt torque - Wrong tightening sequence Injury can result from an inadequately supported monitor. The monitor mount must be capable of supporting 145 lbs (66 kg) of nozzle reaction force. The stream exiting a monitor is very powerful and capable of causing injury and property damage. Make sure the monitor is securely attached to the base and pointing in a safe direction before water to the monitor is turned on. Use care in directing the stream. The monitor may be damaged if frozen while containing sufficient amounts of water. Such damage may be difficult to detect visually and can lead to possible injury or death. Any time the monitor is subject to possible damage from freezing, it must be hydrostatically tested by qualified personnel before being considered safe for use. Keep hands and fingers away from moving parts of the oscillating unit when water is flowing. There are moving parts that can pinch fingers and hands. NOTICE This equipment is intended for use by trained personnel for firefighting. Their use for other purposes may involve hazards not addressed by this manual. Seek appropriate guidance and training to reduce risk of injury. The electric monitor may be remotely operated. The electric drives are current limited but may still produce enough force to cause injury. Keep hands and fingers away from pinch points on the monitor. Do not use the manual override while the electric controls are in operation. The electric drives produce enough torque to cause injury. Exceeding the operating envelope of the monitor can result in injury. Observe safe operation by staying within the published limits. On many vehicle installations, the monitor is the highest point on the apparatus. Be sure there is sufficient clearance to safely pass under any doors or overhead obstructions. Always check parked position of the monitor before moving. To prevent mechanical damage, do not drop or throw equipment. 4

5 3.0 GENERAL INFORMATION The EF1 RC monitor is extremely compact, yet it has a large 1-½ inch waterway, capable of flowing up to 200 gpm, making it the ideal forestry bumper turret. Waterway with turning vane has only 15 psi (1.3 bar) friction loss at 200 gpm (760 l/min). Elevation range is 90 above horizontal to 45 below. Horizontal travel is 270 (135 either side of a center position). Field changeable horizontal travel stops are factory set to give 180 (90 either side of a center position). Designed for 12 VDC or 24 VDC operation, selection is automatic. The motor control circuits use position encoders and current limiting to protect the drive train at the ends of travel. Unit has waterproof factory installed plug on power wire for easy removal or reinstallation. Electric drives and control box are waterproof. Main waterway made from hardcoat anodized ANSI 356-T6 aluminum. Silver powder coat finish. Various inlets are available. 3.1 PART IDENTIFICATION REMOVE CAP TO ACCESS MANUAL OVERRIDE HEX NUT FOR ELEVATION ELEVATION GREASE FITTING TURNING VANE OUTLET HORIZONTAL GREASE FITTING Y1165 ELECTRONICS ENCLOSURE ef1 rc MADE IN USA MODEL# SERIAL# MODEL & SERIAL NUMBER ON LABEL INLET FLANGE HORIZONTAL ROTATION TRAVEL STOP SEE SECTION 4.2 Fig. 3.1 EF1 RC Monitor Part Identification 5

6 3.2 SPECIFICATIONS MECHANICAL Electric US METRIC Weight 14.2 lbs 6.5 kg Min. Flow Area 1.5 Inlet 1.77 in cm 2 Min. Flow Area 2.0 Inlet 3.14 in cm 2 Max Flow See figure Max Operating Pressure 200 psi 14 bar Horizontal Travel Range SAFE OPERATING ENVELOPE 270 (135 left and right) Materials Used ANSI A356.0-T6 Aluminum, Stainless Maximum Torque Elevation 26 ft lbs 35 n m Maximum Torque Horizontal 26 ft lbs 35 n m Speed Elevation 33 deg/sec Speed Horizontal 33 deg/sec 225 EF1 Opera ng Envelope Flow (lpm) K=2 NOZZLE MONITOR LOSS Monitor Inlet Pressure Pressure (psi) K=8 NOZZLE K=15 NOZZLE 8 6 Pressure (bar) K=20 NOZZLE Nozzle Pressure Flow (gpm) Nozzle A flows 20 gpm (80 l/min) at 100 psi (7 bar), K factor = 2 Nozzle B flows 80 gpm (300 l/min) at 100 psi (7 bar), K factor = 8 Nozzle C flows 150 gpm (570 l/min) at 100 psi (7 bar), K factor = 15 Nozzle D flows 200 gpm (760 l/min) at 100 psi (7 bar), K factor = 20 Figure Safe Operating Envelope 0 6

7 Y USE WITH SALT WATER Use with salt water is permissible provided the monitor is thoroughly cleaned with fresh water after each use. The service life of the monitor may be shortened due to the effects of corrosion and is not covered under warranty. 3.4 INLET AND OUTLET OPTIONS Available inlets and outlets are shown below and should be specified at time of order. Note: Outlet thread options are machined into elbow. OUTLET OPTIONS OPTION # THREAD ELBOW 1 1.5" NH MALE Y1311ANF NPSH MALE Y1311AIF BSP MALE Y1311ABF ef1 rc MADE IN USA MODEL# SERIAL# 2.0" BSP FEMALE (Y1403) 1.5" BSP FEMALE (Y1402) 2.0" ANSI 150 (Y1417) 1.5" ANSI 150 (Y1412) 2.0" NPT FEMALE (Y1401) 1.5" NPT FEMALE (Y1400) INLET OPTION Fig 3.4a Inlets and Outlets Weight 2.0" BSP FEMALE (Y1403) 2.1 lb 0.95 kg 1.5" BSP FEMALE (Y1402) 2.1 lb 0.95 kg 2.0" ANSI 150 (Y1417) 3.0 lb 1.4 kg 1.5" ANSI 150 (Y1412) 2.2 lb 1.0 kg 2.0" NPT FEMALE (Y1401) 2.1 lb 0.95 kg 1.5" NPT FEMALE (Y1400) 2.1 lb 0.95 kg Figure 3.4b Inlet Weight 7

8 3.5 OVERALL DIMENSIONS 135 LEFT 2.2 [55mm] 7.0 [178mm] 135 RIGHT 7.0 [178mm] SWING [276mm] [85mm] 2.7 [69mm] INLET OPTION Fig 3.5a EF1 RC Monitor Dimensions Additional Overall Height 2.0" BSP FEMALE (Y1403) 2.7 in 69 mm 1.5" BSP FEMALE (Y1402) 2.7 in 69 mm 2.0" ANSI 150 (Y1417) 1.8 in 45 mm 1.5" ANSI 150 (Y1412) 1.7 in 43 mm 2.0" NPT FEMALE (Y1401) 2.7 in 69 mm 1.5" NPT FEMALE (Y1400) 2.7 in 69 mm Fig 3.5b Inlet Heights 8

9 4.0 INSTALLATION See Remote Control (RC) Monitor Electrical Controls Supplemental Instructions (LIY-500) For RC monitor. 4.1 STRUCTURAL REQUIREMENTS The structure that the EF1 RC Monitor is mounted to must withstand the internal pressure of the monitor as well as shear and bending forces due to nozzle reaction. Nozzle reaction can be as high as 150 lbs (70 kg) (200 gpm at 200 psi). For flanged connections the use of flat flanges without raised faces is recommended. Use a ring gasket as defined in ASME or ISO Tighten flange bolts in an alternating sequence as shown in figure 4.1. Tighten sequentially each bolt or stud three times with 30%, then 60%, and finally 100% of the specified torque. Tighten to ft-lb ( Newton-Meters). FLANGE TYPE OUTSIDE THICKNESS DIAMETER 3 BOLT HOLE CIRCLE Tighten Sequentially Each Bolt Three Times Fig 4.1 Flange Bolt Tightening Sequence # OF BOLTS SIZE OF BOLTS TORQUE ON BOLTS in mm in mm in mm in mm ft-lb N-m 1.5 ANSI / ANSI / TRAVEL RANGES The EF1 RC Monitor is available with various inlet fittings. These Inlet Adapters must be oriented upon installation so the EF1 RC will point in the desired direction. Figure 3.4A shows examples of Inlet Adaptors. Travel ranges relative to the Straight Ahead Reference Mark are shown in Figure 4.2. Figure gives the location of the travel stops. 135 LEFT RIGHT HORIZONTAL TRAVEL ELEVATION TRAVEL Fig 4.2 Travel Ranges Relative to Straight Ahead Reference Mark 9

10 Y TRAVEL STOPS Vertical Travel Stops are cast into the elbow of the monitor. Instructions on how to install horizontal travel stops are shown below. Y1165 ef1 rc MADE IN USA MODEL# SERIAL# 1. Rotate horizontal travel stop 90 one direction and insert into coupling track. 2. Rotate back to original position ensuring the letter is located at the top of the travel stop. 3. Rotate the monitor to the desired position, position the travel stop next to the Monitor's Stop Ear. 4. Tighten set screws to lock the travel stop position. 4.3 NOZZLE INSTALLATION The nozzle is simply screwed onto the monitor s exit threads. 4.4 PRESSURE GAGE There is a raised boss on the front of the monitor. This raised boss is not machined from the factory but may be drilled and tapped for ¼ NPT threads if a pressure gage is desired on the monitor. Fig Travel Stops The nozzle threads must match the threads of the monitor elbow in both size and type. Mismatched or damaged threads may cause the nozzle to leak or uncouple under pressure and could cause injury. Do not connect aluminum to brass or brass to aluminum. Dissimilar metals coupled together can cause galvanic corrosion that will freeze the threaded joint or cause complete loss of thread engagement. If dissimilar metals must be coupled together, the effects of corrosion can be greatly delayed by various coatings on the metal such as powder paint, hard anodizing, or silicone grease. ef1 rc MADE IN USA MODEL# SERIAL# Fig 4.4 Pressure Gage 10

11 4.5 DRAINING RESIDUAL WATER There is no drain on the EF1 RC Monitor itself. A drain valve should be installed on the piping to which the monitor is attached. All monitors, valves, and standpipes exposed to freezing conditions must be drained immediately following use to prevent damage. To drain a standpipe, a drainage port must be opened underground below the frost depth to keep water out of the standpipe until the next use. 5.0 SPRAY TRAJECTORY ADJUSTMENT 6.0 OPERATION OF RC MONITORS Injury can result from the monitor changing direction due to an off center nozzle reaction. An off center nozzle reaction may be caused by debris in the nozzle causing an asymmetrical stream. See Remote Control (RC) Monitor Electrical Controls Supplemental Instructions LIY-500 for operation of the EF1 RC Monitor. 7.0 RECOMMENDED PARK POSITION For truck mounted applications it is recommended that the monitor be parked in a position such that the monitor s nozzle rests against a bracket or support surface. If a support surface is not available, run the elevation against one of its travel stops to take some of the backlash out of the gear drive. This will minimize bouncing of the nozzle when the apparatus is traveling. Always be sure the monitor is properly parked before moving the truck and know the overall height to avoid damage from overhead obstructions such as doors or bridges. See Remote Control (RC) Monitor Electrical Controls Supplemental Instructions (LIY-500) for information on programming, OSCILLATE and PARK position of the EF1 RC monitor. 7.1 OVERRIDE HEX DRIVE In the event of electrical system failure on the monitor or fire truck, the EF1 RC Monitor is factory supplied with a hex drive so a 1/4 hex wrench may be used for manual override. Pry the dust caps off from the horizontal or vertical shafts to access the hex drives. ¼ Hex Wrench Fig 7.1 Wrenching Hexes on Drive Shafts 11

12 8.0 CHARACTERISTICS 8.1 STACKED TIPS NOZZLE DIAMETER (GPM) NOZZLE INLET PRESSURE 50 PSI 80 PSI 100 PSI 150 PSI 175 PSI (LBS) (GPM) (LBS) (GPM) (LBS) (GPM) (LBS) (GPM) (LBS) 1/2 INCH /8 INCH /4 INCH NOZZLE DIAMETER (l/min) NOZZLE INLET PRESSURE 4 BAR 6 BAR 8 BAR 10 BAR 12 BAR (KG) (l/min) (KG) (l/min) (KG) (l/min) (KG) (l/min) (KG) 12 MM MM MM EF1 MONITOR FRICTION LOSS Fig. 8.1 Stacked Tips Flow Table LOSS (PSI) (LPM) (GPM) LOSS (BAR) Fig 8.2 Friction Loss 12

13 Y DRAWING & PARTS LIST ef1 rc MADE IN USA MODEL# SERIAL# ITEM # DESCRIPTION QTY PART # 1 BRAND LABEL 1 Y LABEL 1 ZB O-RING VO M4-0.7 X 25MM SOCKET 5 VTM4-0.7SH25 HEAD CAP SCREW 5 ENCLOSURE LID 1 Y O-RING VO O-RING VO X 3/16 SOCKET HEAD 4 VT06-32SH188 CAP SCREW 9 SIGNAL AND COMMUNICA- 1 Y5010 TION BOARD 10 MOTOR CONTROL BOARD 1 Y CIRCUIT BOARD STANDOFF 2 Y HEX PLUG 1 Y GREASE FITTING 1/ VT25-28ZERK 14 3/8-24 X 3/8 SOCKET SET 4 VT37-24SS375 SCREW 15 BALL 5/16" TORLON 100 VB.312TO 16 O-RING VO ELBOW 1 See Fig STRAIN RELIEF 1 Y STRAIN RELIEF 1 Y5205 ITEM # DESCRIPTION QTY PART # 20 MOTOR MOUNT RETAINER 2 Y DRIVE SHAFT SUBASSEMBLY 2 Y SNAP RING 2 VR O-RING VO CAP 2 Y NAME LABEL 1 Y /4-20 X 3/8 BUTTON HEAD 1 VT25-20BH375 CAP SCREW 27 3/8 LOOP CLAMP 1 Y TRAVEL STOP RIGHT 1 Y /4-20 X 5/16 SOCKET SET 4 VT25-20SS312 SCREW 30 RIGID BASE 1.5" ANSI See Fig TRAVEL STOP LEFT 1 Y X 3/8 SOCKET HEAD CAP 2 VT08-32SH375 SCREW 33 STOP EAR 1 Y X 1/4 SET SCREW 1 VT10Y32SS LOWER SECTION 1 Y M4-0.7 X 8MM SOCKET HEAD 8 VTM4-0.7SH8 CAP SCREW 37 MOTOR MOUNT 2 Y GEAR MOTOR 2 Y

14 10.0 WARRANTY Task Force Tips, Inc., 3701 Innovation Way, Valparaiso, Indiana USA ( TFT ) warrants to the original purchaser of its nozzles and other equipment ( equipment ), and to anyone to whom it is transferred, that the equipment shall be free from defects in material and workmanship during the five (5) year period from the date of purchase. TFT s obligation under this warranty is specifically limited to replacing or repairing the equipment (or its parts) which are shown by TFT s examination to be in a defective condition attributable to TFT. To qualify for this limited warranty, the claimant must return the equipment to TFT, at 3701 Innovation Way, Valparaiso, Indiana USA, within a reasonable time after discovery of the defect. TFT will examine the equipment. If TFT determines that there is a defect attributable to it, it will correct the problem within a reasonable time. If the equipment is covered by this limited warranty, TFT will assume the expenses of repair. If any defect attributable to TFT under this limited warranty cannot be reasonably cured by repair or replacement, TFT may elect to refund the purchase price of the equipment, less reasonable depreciation, in complete discharge of its obligations under this limited warranty. If TFT makes this election, claimant shall return the equipment to TFT free and clear of any liens and encumbrances. This is a limited warranty. The original purchaser of the equipment, any person to whom it is transferred, and any person who is an intended or unintended beneficiary of the equipment, shall not be entitled to recover from TFT any consequential or incidental damages for injury to person and/or property resulting from any defective equipment manufactured or assembled by TFT. It is agreed and understood that the price stated for the equipment is in part consideration for limiting TFT s liability. Some states or countries do not allow the exclusion or limitation of incidental or consequential damages, so the above may not apply to you. TFT shall have no obligation under this limited warranty if the equipment is, or has been, misused or neglected (including failure to provide reasonable maintenance) or if there have been accidents to the equipment or if it has been repaired or altered by someone else. THIS IS A LIMITED EXPRESS WARRANTY ONLY. TFT EXPRESSLY DISCLAIMS WITH RESPECT TO THE EQUIPMENT ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND ALL IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE. THERE IS NO WARRANTY OF ANY NATURE MADE BY TFT BEYOND THAT STATED IN THE DOCUMENT. This limited warranty gives you specific legal rights, and you may also have other rights which vary from state to state. 14

15 11.0 MAINTENANCE The EF1 RC Monitor requires little maintenance. The unit should be kept clean and free of dirt by rinsing with water after each use. Any inoperable or damaged parts should be repaired or replaced before placing the unit in service. Equipment can be returned to the factory for service and/or testing LUBRICATION Any alterations to the monitor and its markings could diminish safety and constitutes a misuse of this product The EF1 monitor generally should not require greasing. In the event that the operation becomes stiff grease may be applied to the horizontal rotation and elevation worm gears. See figure 3.1 for grease port locations. Use medium viscosity automotive chassis grease. Apply only enough grease to restore normal operation. If normal operation is not restored by greasing than inspect for other causes of stiff operation. Note: Do not over pump grease. The monitor s greased areas lead to large chambers that could trap several pounds of grease before becoming visible TROUBLESHOOTING SYMPTOM POSSIBLE CAUSE REMEDY Leaks Debris or damage in seal area Clean out debris or replace damaged parts Elevation Binding Debris or damage to elevation drive parts Clean out debris or replace damaged parts Horizontal Rotation Binding Lack of lubricant Grease, see section 11.1 May be electrical related Debris or damage to horizontal drive parts See trouble shooting section of Electronics Manual LIY-500 Clean out debris or replace damaged parts Lack of lubricant Grease, see section 11.1 May be electrical related See trouble shooting section of Electronics Manual LIY REPAIR Factory service is available with repair time seldom exceeding one day in our facility. Factory serviced appliances are repaired by experienced technicians to original specifications, fully tested, and promptly returned. Repair parts and service procedures are available for those wishing to perform their own repairs. Task Force Tips assumes no liability for damage to equipment or injury to personnel that is a result of user service. For additional information on care, maintenance, and testing, refer to: NFPA 1962: Standard for the Care, Use, Inspection, Service Testing, and Replacement of Fire Hose, Couplings, Nozzles, and Fire Hose Appliances, 2013 Edition 12.0 ANSWERS TO YOUR QUESTIONS We appreciate the opportunity of serving you and making your job easier. If you have any problems or questions, our toll-free Hydraulics Hotline, , is normally available to you 24 hours a day, 7 days a week. 15

16 13.0 INSPECTION CHECKLIST BEFORE EACH USE, appliances must be inspected to this checklist: All valves (if so equipped) open and close fully and smoothly Waterway is clear of obstructions There is no damage to any thread or other connection All locks and hold-down devices work properly The pressure setting on the relief valve (if so equipped) is set correctly Gaskets are in good repair There is no obvious damage such as missing, broken, or loose parts There is no damage to the appliance that could impair safe operation (e.g. dents, cracks, corrosion, or other defects) All swiveling elements rotate freely Nozzle is securely attached BEFORE BEING PLACED BACK IN SERVICE, appliances must be inspected to this list: 1. All valves open and close smoothly and fully 2. The waterway is clear of obstructions 3. There is no damage to any thread or other type connection 4. The pressure setting of the relief valve, if any, is set correctly 5. All locks and hold-down devices work properly 6. Internal gaskets are in accordance with NFPA 1962 (2013) Section There is no damage to the appliance that could impair safe operation (e.g. dents, cracks, corrosion, or other defects) 8. All swiveling connections rotate freely 9. There are no missing parts or components 10. The marking for maximum operating pressure is visible 11. There are no missing, broken, or worn lugs on couplings NFPA 1962: Standard for the care, use, inspection, service testing, and replacement of fire hose, couplings, nozzles and fire hose appliances. (2013 ed., Section 6.2.1). Quincy, MA: National Fire Protection Agency. Any monitor failing any part of the inspection checklist is unsafe and must have the problem corrected before use. Operating a monitor that fails any of the above inspections is a misuse of this equipment. TASK FORCE TIPS, INC. MADE IN USA Innovation Way, Valparaiso, IN USA Fax

MANUAL: IN-LINE PIVOT GAUGE IN-LINE GAUGE

MANUAL: IN-LINE PIVOT GAUGE IN-LINE GAUGE MANUAL: IN-LINE PIVOT GAUGE IN-LINE GAUGE INSTRUCTIONS FOR INSTALLATION, SAFE OPERATION AND MAINTENANCE WARNING Understand manual before use. Operation of this device without understanding the manual and

More information

MANUAL: Jumbo Siamese and Jumbo Wye

MANUAL: Jumbo Siamese and Jumbo Wye TASK FORCE TIPS FIRE FIGHTING EQUIPMENT MANUAL: Jumbo Siamese and Jumbo Wye INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE Read instruction manual before use. Operation of this device without understanding

More information

MANUAL: Jumbo Gate Valve

MANUAL: Jumbo Gate Valve MANUAL: Jumbo Gate Valve INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE Read instruction manual before use. Operation of this device without understanding the manual and receiving proper training is a

More information

MANUAL: 5-WAY MANIFOLD

MANUAL: 5-WAY MANIFOLD MANUAL: 5-WAY MANIFOLD INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE NOTICE NOTICE Read Instruction Manual before use. Operation of this manifold without understanding the manual and receiving proper

More information

MANUAL: SHO-FLOW Flow Meter Operations

MANUAL: SHO-FLOW Flow Meter Operations MANUAL: SHO-FLOW Flow Meter Operations INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE Understand manual before use. Operation of this device without understanding the manual and WARNING receiving proper

More information

INSTRUCTIONS FOR INSTALLATION, SAFE OPERATION AND MAINTENANCE. Monitor Mounted Operator Station SECTION 4.2. Tethered Operator Station (Y4E-CT-##)

INSTRUCTIONS FOR INSTALLATION, SAFE OPERATION AND MAINTENANCE. Monitor Mounted Operator Station SECTION 4.2. Tethered Operator Station (Y4E-CT-##) MANUAL: TSUNAMI & TSUNAMI RC MONITOR See LIY-500 Remote Control (RC) Monitor Electrical Controls Supplemental Instructions For Use With Tsunami RC Models INSTRUCTIONS FOR INSTALLATION, SAFE OPERATION AND

More information

MANUAL: PROTECTOR STATION MONITOR

MANUAL: PROTECTOR STATION MONITOR MANUAL: PROTECTOR STATION MONITOR INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE WARNING Understand manual before use. Operation of this device without understanding the manual and receiving proper training

More information

MANUAL: LDH GATED WYE

MANUAL: LDH GATED WYE MANUAL: LDH GATED WYE INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE NOTICE Read Instruction Manual before use. Operation of this device without understanding the manual and receiving proper training

More information

AWG Fittings LLC. Pressure Relief Valve Up to 250 PSI. Product Number Read this instruction manual before use.

AWG Fittings LLC. Pressure Relief Valve Up to 250 PSI. Product Number Read this instruction manual before use. AWG Fittings LLC Pressure Relief Valve Up to 250 PSI Product Number 30004033 Read this instruction manual before use. Using this device without t understanding di this products operation and care may lead

More information

MANUAL: LDH GATED WYE

MANUAL: LDH GATED WYE MANUAL: LDH GATED WYE INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE NOTICE Read Instruction Manual before use. Operation of this device without understanding the manual and receiving proper training

More information

MANUAL: OASIS HYDRANT ASSIST VALVE

MANUAL: OASIS HYDRANT ASSIST VALVE MANUAL: OASIS HYDRANT ASSIST VALVE INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE Read instruction manual before use. Operation of this device without understanding the manual and receiving proper training

More information

Installation, Operation & Maintenance Manual for Flo-Max Coupler Bracket Model FM150

Installation, Operation & Maintenance Manual for Flo-Max Coupler Bracket Model FM150 Installation, Operation & Maintenance Manual for Flo-Max Coupler Bracket Model FM150 January 2013 Form FVC 084 - Rev 02 IMPORTANT: KEEP THIS DOCUMENT WITH THE PRODUCT UNTIL IT REACHES THE END USER. 1.

More information

STYLE 3414/3416 & 3421/3423 Apollo Monitor with Foldaway Legs OPERATING & MAINTENANCE INSTRUCTIONS

STYLE 3414/3416 & 3421/3423 Apollo Monitor with Foldaway Legs OPERATING & MAINTENANCE INSTRUCTIONS STYLE 3414/3416 & 3421/3423 Apollo Monitor with Foldaway Legs OPERATING & MAINTENANCE INSTRUCTIONS The Akron Style 3414/3416 & 3421/3423 Apollo Monitor is designed to provide efficient trouble-free operation

More information

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE INSTALLATION, OPERATION & MAINTENANCE MANUAL INTERFACE DEVICES, INC. 230 Depot Road, Milford, CT 06460 Ph: (203) 878-4648, Fx: (203) 882-0885, E-mail: info@interfacedevices.com

More information

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES INSTRUCTION MANUAL Installation Operation Parts Service IMPORTANT Record your Regulator model number and serial number here for easy reference: Model No. Serial No. Date of Purchase When ordering parts

More information

MANUAL: HYDRANT MASTER

MANUAL: HYDRANT MASTER MANUAL: HYDRANT MASTER REMOTE CONTROL HYDRANT SLIDE VALVE INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE Understand manual before use. Operation of this device without understanding the manual and receiving

More information

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual WHEATLEY SERIES 500 SWING CHECK VALVE STANDARD INTEGRAL SEAT & OPTIONAL REMOVABLE SEAT 2" FP - 6" FP 150# - 1500# 8" FP - 12" FP 150# - 900# API 6D and B16.34 2" FP - 4" FP 5000# DRILLING PRODUCTION VALVE

More information

Models: C62/63/64-A/D

Models: C62/63/64-A/D Installation & Service C62-991-24A3 Models: C62/63/64-A/D Diaphragm Bypass Pressure Regulating Valves IMPORTANT Record your pump model number and serial number here for easy reference: Model No. Serial

More information

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data Technical Services: Tel: (800) 381-312 / Fax: (800) 71-5500 Customer Service/Sales: Tel: (215) 362-0700 / (800) 523-6512 Fax: (215) 362-5385 Model B-1 Pipe Line Strainer 3,, 6 & 8 Inch (DN80, DN100, DN150

More information

MANUAL: CROSSFIRE Monitor

MANUAL: CROSSFIRE Monitor STREAM FOG Operating On Portable Base Below This Stop (pin pulled) Is Dangerous. Read and Understand All Operation and Safety Instructions Before Use. Additional Copies Available 24-hours 800-348-2686

More information

WHEATLEY Series 500 Swing Check Valve

WHEATLEY Series 500 Swing Check Valve Document Number: TC003001-13 Revision: 02 WHEATLEY Series 500 Swing Check Valve Installation, Operation, and Maintenance Manual TABLE OF CONTENTS BILL OF MATERIALS...3 SCOPE...5 INSTALLATION AND OPERATION

More information

Model C Pipe Line Strainer 6, 8 & 10 Inch (DN150, DN200 & DN250) 250 psi (17,2) General Description. Technical Data. Page of 6 MAY, 2006 TFP1644

Model C Pipe Line Strainer 6, 8 & 10 Inch (DN150, DN200 & DN250) 250 psi (17,2) General Description. Technical Data. Page of 6 MAY, 2006 TFP1644 Technical Services: Tel: (00) 31-9312 / Fax: (00) 791-5500 Model C Pipe Line Strainer 6, & 10 Inch (150, & 250) 250 psi (17,2) General Description The welded steel body Model C Pipe Line Strainers (Ref.

More information

Manual: GPK1 - Gin Pole Kit Accessory for the ARRS1-AMKUS Rope Rescue System

Manual: GPK1 - Gin Pole Kit Accessory for the ARRS1-AMKUS Rope Rescue System Copyright Amkus Rescue Systems, Inc. 2016 LAA-001 April 15, 2016 Rev00 Manual: GPK1 - Gin Pole Kit Accessory for the ARRS1-AMKUS Rope Rescue System DANGER Understand manual before use. Operating AMKUS

More information

AIR DISTRIBUTOR. PART NUMBER (Including, but not inclusive) AD28483-_ALB, AD28563-_ALB, AD36097-_ALB, AD36098-_ALB, AD28485-_ALB

AIR DISTRIBUTOR. PART NUMBER (Including, but not inclusive) AD28483-_ALB, AD28563-_ALB, AD36097-_ALB, AD36098-_ALB, AD28485-_ALB Manual #: MM-AD001 12/5/11 Rev. A Page 1 of 8 PART NUMBER (Including, but not inclusive) AD28483-_ALB, AD28563-_ALB, AD36097-_ALB, AD36098-_ALB, AD28485-_ALB Manual #: MM-AD001 12/5/11 Rev. A Page 2 of

More information

CROSSFIRE MANUAL: WITH SAFE-TAK 1250 BASE INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE DANGER. TASK FORCE TIPS, Inc. DANGER

CROSSFIRE MANUAL: WITH SAFE-TAK 1250 BASE INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE DANGER. TASK FORCE TIPS, Inc. DANGER STREAM FOG 800-48-686 CROSSFIRE MANUAL: WITH SAFE-TAK 150 BASE INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE This instruction manual is intended to familiarize firefighters and maintenance personnel

More information

HYDRAULIC PUNCH DRIVER 38456, 38520, 7306 / 7306SB, 7310 / 7310SB, 7506, 7606SB, 7610SB, 7625 / 7625Pg / 7625PgSB, 7646 / 7646Pg / 7646PgSB

HYDRAULIC PUNCH DRIVER 38456, 38520, 7306 / 7306SB, 7310 / 7310SB, 7506, 7606SB, 7610SB, 7625 / 7625Pg / 7625PgSB, 7646 / 7646Pg / 7646PgSB INSTRUCTION MANUAL HYDRAULIC PUNCH DRIVER 38456, 38520, 7306 / 7306SB, 7310 / 7310SB, 7506, 7606SB, 7610SB, 7625 / 7625Pg / 7625PgSB, 7646 / 7646Pg / 7646PgSB Read and understand all of the instructions

More information

Hot Tapping Machine. OPERATIONS MANUAL and OPERATING INSTRUCTIONS

Hot Tapping Machine. OPERATIONS MANUAL and OPERATING INSTRUCTIONS 262-2040 Hot Tapping Machine For performing 1/4 6 Hot taps 285 psi or less. Municipal Water, Sewage, & Building Services Use OPERATIONS MANUAL and OPERATING INSTRUCTIONS WARNING: These instructions are

More information

ULTRA HIGH PRESSURE PAINT GRATE CLEANER FCT-JS OPERATION AND MAINTENANCE MANUAL

ULTRA HIGH PRESSURE PAINT GRATE CLEANER FCT-JS OPERATION AND MAINTENANCE MANUAL ULTRA HIGH PRESSURE PAINT GRATE CLEANER FCT-JS OPERATION AND MAINTENANCE MANUAL 466 S. Skylane Drive DURANGO, COLORADO 81303 970-259-2869 PHONE 970-259-2868 FAX www.stoneagetools.com sales@stoneagetools

More information

III. Identify the initial installation requirements for standpipe systems

III. Identify the initial installation requirements for standpipe systems Design Basic Design Requirements 1. Must provide 500 GPM at 65 PSI to the highest most remote standpipe riser outlet. 2. 250 GPM for each additional standpipe total not to exceed 2500 GPM III. Identify

More information

MANUAL: Low Profile Ball Intake Valve

MANUAL: Low Profile Ball Intake Valve MANUAL: Low Profile Ball Intake Valve INSTRUCTIONS FOR INSTALLATION, SAFE OPERATION AND MAINTENANCE Understand manual before use. Operation of this device without understanding the manual and receiving

More information

MANUAL: LDH VALVED APPLIANCES

MANUAL: LDH VALVED APPLIANCES MANUAL: LDH VALVED APPLIANCES INSTRUCTIONS FOR INSTALLATION, SAFE OPERATION AND MAINTENANCE WARNING Understand manual before use. Operation of this device without understanding the manual and receiving

More information

FOR SAFE OPERATION AND MAINTENANCE

FOR SAFE OPERATION AND MAINTENANCE MANUAL: Blitz Force Portable Monitor INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE DANGER DANGER NOTICE NOTICE Read Instruction Manual before use. Operation of this monitor without understanding the

More information

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Installation, Operation and Maintenance Manual for Back Pressure Regulator Installation, Operation and Maintenance Manual for Back Pressure Regulator Model 8860 2009 Groth Corporation IOM-8860 Rev. B 12541 Ref. ID: 95565 Page 2 of 13 Table of Contents I. INTRODUCTION 3 II. DESIGN

More information

Interface Devices, Inc. Hydraulic Mini Mule

Interface Devices, Inc. Hydraulic Mini Mule Interface Devices, Inc. Hydraulic Mini Mule INSTALLATION, OPERATION & MAINTENANCE MANUAL IMPORTANT! FILE THIS MANUAL IN A SAFE PLACE FOR FUTURE SERVICE & PARTS NEEDS ALWAYS REFERENCE THE SERIAL NUMBER

More information

TITAN FLOW CONTROL, INC.

TITAN FLOW CONTROL, INC. PREFACE: This manual contains information concerning the installation, operation, and maintenance of Titan Flow Control (Titan FCI) Simplex Basket Strainers. To ensure efficient and safe operation of Titan

More information

Model ASSEMBLY and OPERATING INSTRUCTIONS

Model ASSEMBLY and OPERATING INSTRUCTIONS QUICK CHANGE AIR BRUSH KIT Model 93506 ASSEMBLY and OPERATING INSTRUCTIONS Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission Oaks Blvd.,

More information

MANUAL: CROSSFIRE Monitor With Stow-A-Way 800 Base

MANUAL: CROSSFIRE Monitor With Stow-A-Way 800 Base MANUAL: CROSSFIRE Monitor With Stow-A-Way 800 Base DANGER DANGER INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE Understand manual before use. Operation of this device without understanding the manual

More information

KJ4000 Operating Instructions & Parts Manual NSN

KJ4000 Operating Instructions & Parts Manual NSN KJ4000 Operating Instructions & Parts Manual NSN 1025-01-473-7710 Mandus Group Ltd. KJ4000 Operators Manual Date: 3 Jan. 2002 TABLE OF CONTENTS General Safety Instructions...Page 1 Operator Instructions...Page

More information

3" UC Ultra-Chuck Durable Lightweight Air Inflated Bladder Chuck Operation/Repair Manual. (76.2 mm) DOUBLE E COMPANY, INC.

3 UC Ultra-Chuck Durable Lightweight Air Inflated Bladder Chuck Operation/Repair Manual. (76.2 mm) DOUBLE E COMPANY, INC. 3" UC-3000 (76.2 mm) Ultra-Chuck Durable Lightweight Air Inflated Bladder Chuck Operation/Repair Manual DOUBLE E COMPANY, INC. 319 Manley Street, West Bridgewater, MA 02379 U.S.A. Tel: (508) 588-8099 /

More information

FLANGED TWO-PIECE BALL VALVES

FLANGED TWO-PIECE BALL VALVES INTRODUCTION This instruction manual includes installation, operation, and maintenance information for FNW flanged split-body ball valves. This manual addresses lever operated ball valves only. Please

More information

AIR INLINE METAL SHEAR

AIR INLINE METAL SHEAR AIR INLINE METAL SHEAR ASSEMBLY and OPERATING INSTRUCTIONS 3491 Mission Oaks Blvd. / Camarillo, CA 93011 Copyright 1997 by Harbor Freight Tools. All rights reserved. No portion of this manual or any artwork

More information

Model PSI Compressor with 3-Gallon Air Tank 12VDC

Model PSI Compressor with 3-Gallon Air Tank 12VDC Model 6350 150 PSI Compressor with 3-Gallon Air Tank 12VDC IMPORTANT: It is essential that you and any other operator of this product read and understandd the contents of this manual before installing

More information

APOLLO HI-RISER MONITOR STYLE 3433/3431 INSTALLATION, OPERATING, ANDMAINTENANCE INSTRUCTIONS

APOLLO HI-RISER MONITOR STYLE 3433/3431 INSTALLATION, OPERATING, ANDMAINTENANCE INSTRUCTIONS APOLLO HI-RISER MONITOR STYLE 3433/3431 INSTALLATION, OPERATING, ANDMAINTENANCE INSTRUCTIONS The following is intended to provide the basic instructions for installation, operation and maintenance of the

More information

4 IN. BALL LAUNCHER Engine Mounted / PTO Driven

4 IN. BALL LAUNCHER Engine Mounted / PTO Driven 4 IN. BALL LAUNCHER Engine Mounted / PTO Driven OPERATOR S PARTS and MAINTENANCE MANUAL 2006 EDITION BL-MAN-4EN Creation Revision date: 10MAR06 date: by: Ivon LeBlanc by: Table of Contents Table of Contents...

More information

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B September 16, 2013 Trimpac 250a 1. DESCRIPTION DEsCRIPTIoN is a factory assembled trim package for a ed an electric/pneumatic release module in a metal enclosure. The standard trim normally required on

More information

200 PSI COMPRESSORS - MODEL NUMBERS

200 PSI COMPRESSORS - MODEL NUMBERS 200 PSI COMPRESSORS - MODEL NUMBERS 380C AIR COMPRESSOR KIT PART NO. 38033 480C AIR COMPRESSOR KIT PART NO. 48043 380C 480C IMPORTANT: It is essential that you and any other operator of this product read

More information

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity WATER HEATER THERMAL EXPANSION TANKS Owner s Manual Safety Instructions Installation Maintenance Warranty Models: 2-5 Gallon Capacity Thank You for purchasing this Thermal Expansion Tank. Properly installed

More information

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1. 2 GALLON TWIN STACK AIR COMPRESSOR Model: 9526 DO NOT RETURN TO STORE. Please CALL 800-348-5004 for parts and service. CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or

More information

MODEL 840 AIR HYDRAULIC PUMP INSTRUCTION

MODEL 840 AIR HYDRAULIC PUMP INSTRUCTION MODEL 840 AIR HYDRAULIC PUMP INSTRUCTION Jackco Transnational Inc. 202 South El Monte, CA 888-452-2526 www.jackco.com FOR YOUR SAFETY Read all instructions, warnings and cautions carefully. Follow all

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock: - Do not disassemble. Do not attempt repairs or modifications. Refer to qualified service agencies for all service and repairs.

More information

Pipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3

Pipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3 Worldwide Contacts www.tyco-fire.com Model B-1 Pipe Line Strainer General Description The Model B-1 Pipe Line Strainers (Ref. Figures 1 and 2) are designed for installation in the water supply connection

More information

MANUAL: BLITZFIRE Portable Monitor Series

MANUAL: BLITZFIRE Portable Monitor Series MANUAL: BLITZFIRE Portable Monitor Series INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE DANGER DANGER NOTICE NOTICE Understand manual before use. Operation of this device without understanding the manual

More information

MANUAL: LDH VALVED APPLIANCES

MANUAL: LDH VALVED APPLIANCES MANUAL: LDH VALVED APPLIANCES INSTRUCTIONS FOR INSTALLATION, SAFE OPERATION AND MAINTENANCE WARNING Understand manual before use. Operation of this device without understanding the manual and receiving

More information

1 DRIVE INDUSTRIAL IMPACT WRENCH

1 DRIVE INDUSTRIAL IMPACT WRENCH 1 DRIVE INDUSTRIAL IMPACT WRENCH 92622 ASSEMBLY AND OPERATING INSTRUCTIONS 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at http://www.harborfreight.com Copyright 2004 by Harbor Freight

More information

FLANGED TWO-PIECE BALL VALVES

FLANGED TWO-PIECE BALL VALVES INTRODUCTION This instruction manual includes installation, operation, and maintenance information for FNW flanged split-body ball valves. This manual addresses lever operated ball valves only. Please

More information

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS 18 GAUGE 1-1/4 INCH BRAD NAILER Model: 7611 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement, or other masonry.

More information

MANUAL BE SERIES Test Benches

MANUAL BE SERIES Test Benches The CustomCrimp Manual BE Series Test Benches are designed with features that make proof and burst testing of hydraulic hose assemblies a quick and easy procedure. CUSTOMIZED AND SPECIAL DESIGN BENCHES

More information

Index Table. Model 794. Installation, Operating and Maintenance Instructions

Index Table. Model 794. Installation, Operating and Maintenance Instructions CLOCKWISE MANUAL MAKING INTO CCW TABLE Index Table Model 794 Installation, Operating and Maintenance Instructions Black & Webster Products Division 545 Hupp Ave. P.O. Box 831, Jackson, Michigan 49204 2009

More information

3/8" Dr. Air Butterfly Impact Wrench

3/8 Dr. Air Butterfly Impact Wrench 8192106 3/8" Dr. Air Butterfly Impact Wrench Owner s Manual Read and understand all instructions before use. Retain this manual for future reference. Specifications Construction: Polished aluminum and

More information

INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE

INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE MANUAL: Blitz Force Portable Monitor INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE DANGER DANGER Understand manual before use. Operation of this device without understanding the manual and receiving

More information

Pressure Dump Valve Service Kit for Series 3000 Units

Pressure Dump Valve Service Kit for Series 3000 Units Instruction Sheet Pressure Dump Valve Service Kit for Series 000 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00, 400, 500, and 700 applicator

More information

Geotech 1.66 Reclaimer

Geotech 1.66 Reclaimer Geotech 1.66 Reclaimer Installation and Operation Manual Rev 7/1/18 Part # 66 Table of Contents DOCUMENTATION CONVENTIONS... Section 1: System Description... 3 Section : System Installation... 4 Section

More information

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO 420C AIR COMPRESSOR KIT PART NO. 42042 460C AIR COMPRESSOR KIT PART NO. 46043 420C 460C IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this

More information

400C & 450C DUAL PERFORMANCE VALUE PACKS

400C & 450C DUAL PERFORMANCE VALUE PACKS (Chrome) PART NO. 40013 (Silver) PART NO. 45012 (Chrome) PART NO. 45013 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before

More information

444C DUAL PERFORMANCE VALUE PACK

444C DUAL PERFORMANCE VALUE PACK (Chrome) PART NO. 44432 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product. SAVE THIS MANUAL

More information

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP LIMITED WARRANTY Getz Equipment Innovators warrants its products, and component parts of any product manufactured by

More information

Automatic Non-freeze Valve NF6

Automatic Non-freeze Valve NF6 172-65134MA-03 (NF6) 30 March 2015 ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Automatic Non-freeze Valve NF6 Copyright 2015 by TLV CO., LTD. All rights

More information

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS 18 GAUGE 2 INCH BRAD NAILER Model: 7555 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement, or other masonry.

More information

Pressure Dump Valve Service Kit for Series 2300 Units

Pressure Dump Valve Service Kit for Series 2300 Units Instruction Sheet Pressure Dump Valve Service Kit for Series 00 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00 applicator tanks when the unit

More information

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product. Instruction Manual Hydraulic Punch Driver 902-483 LIMITED 1 YEAR WARRANTY We make every effort to assure that its products meet high quality and durability standards, and warrant to the original purchaser

More information

HYDRAULIC WINCH FOR AUGERS UP TO WR10 X 71 / W130 X 41 ASSEMBLY & OPERATION MANUAL

HYDRAULIC WINCH FOR AUGERS UP TO WR10 X 71 / W130 X 41 ASSEMBLY & OPERATION MANUAL HYDRAULIC WINCH ASSEMBLY & OPERATION MANUAL Read this manual before using product. Failure to follow instructions and safety precautions can result in serious injury, death, or property damage. Keep manual

More information

Pressure Relief Valve Instruction Manual

Pressure Relief Valve Instruction Manual CVR3-M0_062017 Pressure Relief Valve Instruction Manual MODEL: CVR3 SFA Companies 10939 N. Pomona Ave. Kansas City, MO 64153 Tel: 888-332-6419 * Fax: 816-448-2142 E-mail: sales@bvahydraulics.com Website:

More information

2000 lb manual winch

2000 lb manual winch 2000 lb manual winch Model 41694 Operation Instructions Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission Oaks Blvd., Camarillo, CA 93011

More information

H4802, H4802-1, H , and Pole Tampers

H4802, H4802-1, H , and Pole Tampers SERVICE MANUAL H4802, H4802-1, H-4802-6, and 43227 Pole Tampers Serial Codes FKA, FKF, FKM, FZP, FZR, FZT, and FZV Read and understand all of the instructions and safety information in this manual before

More information

Instruction Manual. PE Pipe Squeeze-off Tool Model TR650

Instruction Manual. PE Pipe Squeeze-off Tool Model TR650 PE Pipe Squeeze-off Tool Model TR650 Instruction Manual For your personal safety READ and UNDERSTAND instructions before using tools. SAVE these instructions for future reference. SPECIFICATIONS Table

More information

COMPACT METAL bender 99826

COMPACT METAL bender 99826 COMPACT METAL bender 99826 Set up And Operating Instructions Distributed exclusively by Harbor Freight Tools. 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our website at: http://www.harborfreight.com

More information

100C Air Compressor Kit

100C Air Compressor Kit 10010 100C Air Compressor (standard mounting bracket, CE Spec) 10014 100C Air Compressor (no leader hose or check valve, CE Spec) 10016 100C Air Compressor (with Omega Bracket, CE Spec) IMPORTANT: It is

More information

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013 Spetember 16, 2013 Trimpac 251a 1. DEsCrIpTION DESCRIPTION TRIMPAC Model B-6 and B-6B is a factory assembled trim package for a double interlocked preaction system with an electric/pneu-lectric release

More information

DC5A. Cyclone Separator Trap for Air. Copyright 2015 by TLV Co., Ltd. All rights reserved ISO 9001/ ISO MA-03 (DC5A) 19 June 2015

DC5A. Cyclone Separator Trap for Air. Copyright 2015 by TLV Co., Ltd. All rights reserved ISO 9001/ ISO MA-03 (DC5A) 19 June 2015 172-65205MA-03 (DC5A) 19 June 2015 ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Cyclone Separator Trap for Air DC5A Copyright 2015 by TLV Co., Ltd. All rights

More information

BUTTERFLY VALVES Series 800

BUTTERFLY VALVES Series 800 BUTTERFLY VALVES Series 800 WARNING Before proceeding read ALL instructions and become familiar with the equipment and associated drawings. Follow ALL applicable safety regulations and codes for pressurized

More information

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information SIX R431006322 (P -063892-00001) AND SEVEN R431006321 (P -063981--00002) POSITION CYLINDERS Service Information The six and seven position cylinders are medium duty pneumatic positioning devices that operate

More information

Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL

Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Table of Contents

More information

SIGNATURE DEF REELS Models: Bare Reel Reel Reel Reel

SIGNATURE DEF REELS Models: Bare Reel Reel Reel Reel SERVICE BULLETIN SB2023 Rev C 7/11 SIGNATURE DEF REELS Models: 2400-006 Bare Reel 2400-007 16 Reel 2400-008 20 Reel 2400-009 30 Reel Thoroughly read and understand this manual before installing, operating

More information

750 Cable Cutter INSTRUCTION MANUAL

750 Cable Cutter INSTRUCTION MANUAL INSTRUCTION MANUAL 750 Cable Cutter Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Register this product at www.greenlee.com

More information

Bermad Pressure Reducing. Model: 42T

Bermad Pressure Reducing. Model: 42T Bermad Pressure Reducing Pilot Operated Pressure Control Valve Model: 42T Installation Operation Maintenance Manual (IOM) REV. 27.7.17 Page 1 of 12 Safety First BERMAD believes that the safety of personnel

More information

Installation and Operating Manual

Installation and Operating Manual Safety Instructions Important Information Please read prior to installation ATTENTION! ELECTRICAL HAZARD FOR INGROUND POOLS AND ABOVEGROUND POOLS Installation and Operating Manual IMPORTANT Pool Owner,

More information

Vertical Lifeline. Ladder Climb. User Instructions. 3M Occupational Health and Environmental Safety. Fall Protection Equipment

Vertical Lifeline. Ladder Climb. User Instructions. 3M Occupational Health and Environmental Safety. Fall Protection Equipment 3M Occupational Health and Environmental Safety Fall Protection Equipment Ladder Climb Vertical Lifeline User Instructions User Instructions for the 3M TM Ladder Climb Vertical Lifeline System. Important:

More information

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO 250C-IG COMPRESSOR KIT 12V PART NO. 25050 250C-IG COMPRESSOR KIT 24V PART NO. 25058 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual

More information

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight Technical Specifications Operating Instructions Maintenance Information Troubleshooting Guide Parts Diagrams AC1810 / AC1810-A THE EVOLUTION OF PERFECTION CAUTION: Before attempting to use or service this

More information

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock or Electrocution: MODEL NUMBER: 20008 200 PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank IMPORTANT: It is

More information

ROPV R40 E Series User Manual

ROPV R40 E Series User Manual HARBIN ROPV INDUSTRY DEVELOPMENT CENTER ROPV R40 E Series User Manual For Use with the Following ROPV Pressure Vessel Models: R40 300E R40 450E Headquarters Tel:(+86)451-82267301 Fax:(+86)451-82267303

More information

PERSONAL AIR BREATHING UNIT

PERSONAL AIR BREATHING UNIT PERSONAL AIR BREATHING UNIT Operation & Maintenance Manual MARTECH SERVICES C O M P A N Y 1-800-831-1525 Table of Contents INTRODUCTION: Page 2 COMPONENTS DRAWING: Page 3 START UP: Page 4 OPERATION: Page

More information

INSTALLATION, OPERATION AND SERVICE MANUAL ABS AIR BAG LIFT

INSTALLATION, OPERATION AND SERVICE MANUAL ABS AIR BAG LIFT INSTALLATION, OPERATION AND SERVICE MANUAL ABS AIR BAG LIFT P.O. Box 1058 1058 West Industrial Avenue Guthrie, OK 73044-1058 405-282-5200 FAX: 405-282-8105 www.autoquip.com Item # 830ABS Version 1.0 07/2001

More information

FIREFIGHTING EQUIPMENT

FIREFIGHTING EQUIPMENT FIREFIGHTING EQUIPMENT User Manual DEBIKA-INOX Diffuser with adjustable flow & stream settings DOC 1964 En Rev.A - 23/10/13 Identification Product Type Product DESIGNATION Product Reference concerned by

More information

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures MINT-0289-XX TABLE OF CONTENTS Limited Warranty... 3 User Responsibility... 3-4 General Service... 4 Safety Precautions.... 5 Physical Dimensions..

More information

Direct Operated Precision Regulator Modular Style. Standard Specifications

Direct Operated Precision Regulator Modular Style. Standard Specifications 1 Direct Operated Precision Regulator Modular Style Series P3 Courtesy of Steven Engineering, Inc.-23 Ryan Way, South San Francisco, CA 948-637-Main Office: (65) 588-92-Outside Local Area: (8) 258-92-www.stevenengineering.com

More information

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE MODEL NUMBER: M20005 AIR SOURCE KIT 30% Duty Compressor on 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE USER MANUAL IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock

More information

Hydraulic Punch Drivers

Hydraulic Punch Drivers SERVICE MANUAL 7804SB / 7806SB Quick Draw 7704SB / 7706SB Quick Draw Flex Quick Draw Hydraulic Punch Drivers Serial Codes AHJ and YZ Read and understand all of the instructions and safety information in

More information

Vessel Installation and Operating Manual

Vessel Installation and Operating Manual For In-ground and Aboveground Pools Vessel Installation and Operating Manual Important Safety Information Please read this manual prior to installation. Nature 2 Express is designed to sanitize in-ground

More information

1700ESL Kamvalok Coupler

1700ESL Kamvalok Coupler PART #H32138PA November 2008 1700ESL Kamvalok Coupler OPW Transport Series Dry Disconnect Couplings are considered the standard of the industry. For use on multi-compartment petroleum, solvent and chemical

More information