GENERAL INFORMATION...

Size: px
Start display at page:

Download "GENERAL INFORMATION..."

Transcription

1

2 CONTENTS CONTENTS 1. GENERAL INFORMATION... 2 PURPOSE... 2 OPERATOR'S RESPONSIBILITY FOR PATIENT SAFETY... 2 MARKINGS... 2 WARNINGS... 2 General safety warnings... 3 Electrical system safety warnings... 3 WARNING NOTICES AND SYMBOLS... 4 USE... 5 STORAGE AND TRANSPORT EQUIPMENT DESCRIPTION TECHNICAL DATA OPERATION INSTALLATION AND FIRST OPERATION Removal of transport stabilizers Wheel installation Compressed air connection Electrical connection First operation Accessories PERSONNEL Switching the compressor on Running the compressor Cleaning and replacing the filters Cleaning the compressor MAINTENANCE REPAIRS AND SERVICE Cover removal MAINTENANCE SCHEDULE Service interval signalization Safety valve check Check tightness of joints and inspect the equipment Replacing filters elements Setting outlet air pressure Cleaning the pressure regulator Replacing the inlet filter (21) Stabilizing the compressor before shipping SHUT-DOWN EQUIPMENT DISPOSAL BATTERY DISPOSAL TROUBLESHOOTING SPARE PARTS ELECTRIC AND PNEUMATIC DIAGRAMS WIRING DIAGRAM PNEUMATIC DIAGRAM NP-DK50 DS-19_

3 GENERAL INFORMATION 1. GENERAL INFORMATION PURPOSE The EKOM DK50 DS is a medical air compressor that supplies clean, oil-free compressed air for use with medical ventilators. OPERATOR'S RESPONSIBILITY FOR PATIENT SAFETY The Installation, Operation and Maintenance Manual is an integral part of the equipment and must be kept with the compressor. Careful review of this manual will provide information necessary for correct operation of the equipment. Rx only US Federal law restricts the sale of this device by or on the order of a physician. MARKINGS Products marked with the CE mark of compliance meet the safety requirements of the European Union (93/42/EEC). WARNINGS The safety of operating personnel and trouble-free operation of the equipment are ensured only if original parts are used. Only accessories and spare parts mentioned in the technical documentation or expressly approved by the manufacturer can be used. If any other accessories or consumable materials are used, the manufacturer cannot be held responsible for the safe operation and functionality of the equipment. The warranty does not cover damages resulting from the use of accessories or consumable materials other than those recommended by the manufacturer. The manufacturer assumes responsibility for the safety, reliability and function of the equipment only if: - Installation, calibration, amendments, extensions and repairs are performed by the manufacturer, one of its representatives or a service provider authorized by the manufacturer - The equipment is used in accordance with the Installation, Operation and Maintenance Manual The Installation, Operation and Maintenance Manual accurately describes the design of the compressor and its compliance with safety and technical standards. The manufacturer reserves all rights to its wiring diagrams, procedures and names. 2 NP-DK50 DS-19_

4 GENERAL INFORMATION General safety warnings The equipment is designed to operate safely when used correctly. Please note the following safety measures to avoid injury or damage. Equipment operation must comply with all local codes and regulations. Original packaging should be kept for the possible return of the unit. Only original packaging ensures optimal protection of the equipment during transport. If it is necessary to return the equipment during the warranty period, the manufacturer is not liable for damages caused by incorrect packaging. The user must immediately notify the supplier if any problem occurs during the use of the equipment. This product is not intended for use in areas where there is a risk of an explosion. Do not operate the compressor in the presence of flammable anesthetics. Never feed oxygen or nitrous oxide into the compressor. Compressor components are not approved for oxygen or nitrous oxide use. Electrical system safety warnings The equipment must be connected to ground. I order to assure proper grounding, connect the compressor to a receptacle marked "hospital grade." Before the compressor is plugged in, make sure that the voltage and frequency of the mains specified on the equipment are the same as the power mains. Before operating, check for possible damage to the equipment and any connections. Damaged pneumatic and electrical lines must be replaced immediately. If a technical failure occurs, immediately disconnect the equipment from the mains (pull out the main power plug). During repairs and maintenance, ensure that: - The main power plug is removed from the power socket - Compressed air lines are disconnected - All pressure has been released from the air tank Only a qualified technician can install this equipment. NP-DK50 DS-19_

5 GENERAL INFORMATION WARNING NOTICES AND SYMBOLS The following symbols are used for important information in the Installation, Operation and Maintenance Manual and on packaging and the product: Attention, see instructions for use Caution, risk of electric shock Consult instructions for use CE mark of compliance Caution, hot surface Handling mark on package FRAGILE Handling mark on package THIS SIDE UP Handling mark on package KEEP DRY Handling mark on package TEMPERATURE LIMITATIONS Handling mark on package LIMITED STACKING Mark on package RECYCLABLE MATERIAL Alternating current Ground connection Equipotentiality Fuse Condensate drain Never dispose of the battery with common household waste. 4 NP-DK50 DS-19_

6 GENERAL INFORMATION USE The equipment can be installed and operated only in a dry, ventilated and dust-free area. Climatic conditions for operation - see Technical data. The compressor must stand on a flat and stable base. The compressor must not be exposed to rain. The equipment must not be used in humid or wet environments. Never use the compressor in the presence of flammable liquids or gases. Before connecting the compressor to respiration equipment, make sure that it meets the requirements of the respiration equipment. Refer to the Technical data for this purpose. Any use other than the compressor s intended use is not considered to be safe. The manufacturer is not responsible for any damages that result if the compressor is used for any other purpose. Risk is exclusively assumed by the operator/user. STORAGE AND TRANSPORT The compressor is shipped from the factory in transport packaging with the pump stabilized, protecting it from damage during transport. For transport, always use the original packaging and secure the compressor in the upright position. Protect the compressor from humidity, contamination and extreme temperatures during transport and storage. A compressor in its original packaging should be stored in a warm, dry and dust-free area. Keep the packaging material, if possible. If not, dispose of the packaging material in an environmentally-friendly way. Cardboard can be recycled. Before moving or transporting the compressor, the pressure in the air tank and hoses must be released and any condensed water must be drained. Secure the motor to prevent movement before shipping. Prior to transport it is necessary to secure the motor inside the compressor (Chapter 5.) NP-DK50 DS-19_

7 EQUIPMENT DESCRIPTION 2. EQUIPMENT DESCRIPTION 1. Display the primary display indicates outlet pressure 2. PRESSURE - alarm at low outlet pressure 3. TEMP - alarm at high operating temperature 4. DRYING indicates drying level; yellow = unsatisfactory, green = satisfactory 5. MAINS loss of power alarm 6. TIME hours of operation are displayed when the button is pressed 7. BATTERY low battery indication = yellow 8. POWER device status indicator = green 9. OUT compressor outlet air 10. WALL - inlet air coming from an outside compressed air source 11. Main inlet, power switch, primary fuses 12. Equipotential (ground) pin 13. Socket for the electrical cord 14. Condensate tank 15. Air intake filter 16. Compressor 17. Safety valve 18. Air tank 19. a. Filter (40 μm) and water trap 19. b. Filter (5 μm) and water trap 20. Pressure regulator 21. Intake filter 22. Control electronics 23. Cooler The compressor contains of an oil-free piston (16) driven by a low-maintenance singlephase electric motor. Compressed air is cooled in the cooler (23) where condensed water is separated into a separate tank (14). Incoming air passes through two filters (15, 21) undergoing double filtration as it passes through the system (19). The model with a membrane dryer is intended for applications that require a higher level of air dryness. Constant outlet pressure is maintained by pressure regulator (20). The built-in air tank (18) enables peak air consumption of 200 L/min. The device may be used as a standby compressed air source. In this configuration, the respiratory equipment is supplied with compressed air from the central compressed air lines of the medical facility. Air pressure in the central compressed air line is monitored by a pressure sensor. If the pressure is sufficient, the compressor stays in STANDBY mode. If the pressure falls, the control unit automatically puts the compressor into operation. When the compressor is used as the main source of air, the control unit determines its operation according to the current demand for air. If air consumption is zero, the device switches to STANDBY mode. The compressor is equipped with indicators for outlet pressure (1), operating hours (6), power status (8), drying status (4) and battery condition (7). Acoustic and optical alarms activate to warn of high operating temperature (3), low outlet pressure (2) and loss of power (5). 6 NP-DK50 DS-19_

8 NP-DK50 DS-19_ EQUIPMENT DESCRIPTION

9 TECHNICAL DATA 3. TECHNICAL DATA TYPE DK50 DS VERSION basic standard advanced Outlet flow at pressure 3.5 bar (51 psig) Liters/min Peak flow 200* L/min ( 7 Cft/min ) Voltage / Frequency / Nominal current V/Hz/A 230/50 / /60 / /60 / /60 / 5.6 UL model** 100/50-60 / /50 / /60 / /60 / /50-60 / /50 / /60 / /60 / 6 100/50-60 / 6 Air filtration m 5 Pressure dew point at 40 L/min ( 1.4 Cft/min), 3 bar( 43.5 psig ), 20 C (68 F) 5 C (9 F) below the ambient temperature 10 C (18 F) with membrane dryer (optional) Outlet connection DISS 1160-A (3/4"-16 UNF) optional NIST (EN 739) Sound level db(a) 50 Hz Hz Mode of operation Continuous - S1 Separation of condensed water Automatic Indication of drying Yellow (working pressure < 4 bar (58 psig) ) Green (working pressure 4 bar (58 psig) ) Low pressure alarm Decrease in outlet pressure under 2.1 bar ( 30.5 psig ) Cooling failure alarm Increase in internal temperature above 80 C (176 F) Outlet pressure 3.0 bar (43 psig) Adjustable to max. 3.5 bar (51 psig) Automatic start up pressure (backup) Decrease in pressure in the central air line under 2.8 bar ( 40.6 psig) Air tank capacity 2 L (0.61gall UK) Pressure range 5 bar ( 72.5 psig ) 6.5 bar ( 94 psig) Operating pressure of safety valve 7 bar ( psig ) Adjustment of outlet air pressure Pressure regulator Dimensions of compressor w x d x h 445 x 355 x 440 mm ( 17.5 x 14 x 17 in ) Dimensions of compressor with weels w x d x h 470 x 380 x 520 mm ( 18.5 x 15x 20.5 in ) Dimensions of compressor with trolley w x d x h 535 x 575 x 1054 mm ( 21 x 22,5 x 41.5 in ) Dimensions of packaging w x d x h 510 x 480 x 470 mm ( 20 x 19 x 18.5 in ) Dimensions of packaging 560 x 630 x 760 mm ( 22 x 25 x 30 in ) Net weight 34 kg ( 75 lbs ) Net weight of compressor with weels 36 kg ( 80 lbs ) Net weight of compressor with trolley 45 kg ( 99 lbs ) Gross weight 41 kg ( 91 lbs ) Gross weight of compressor with weels 43 kg ( 95 lbs ) Gross weight of compressor with trolley 60 kg ( 132 lbs ) Implementation according to EN , EN ** UL Model UL , Type B class I. CAN/UCSA.C M90 Classification acc. to MDD 93/42 EEC, 2007/47 EC II b * With 0.6 bar pressure drop (8.7 psig) Climatic conditions for storage and transport Temperature 25 C to +55 C (-13 F to +131 F), 24 hrs +70 C (+158 F) Relative air humidity 10% to 90 % (no condensation) Relative air humidity for seaworthy packing 10% to 100% (with condensation) Climatic conditions for operation Temperature +15 C to +40 C (+59 F to +104 F) Relative air humidity up to +95% IPX0 Rating 8 NP-DK50 DS-19_

10 TECHNICAL DATA FAD efficiency correction for differences in elevation FAD correction table Elevation [mamsl] FAD [l/min] FAD x 1 FAD x 0.8 FAD x 0.71 FAD x 0.60 FAD efficiency refers to conditions at an elevation of 0 mamsl: Temperature: 20 C Atmospheric pressure: Pa Relative humidity: 0% NP-DK50 DS-19_

11 OPERATION 4. OPERATION INSTALLATION AND FIRST OPERATION Do not use the compressor immediately after unpacking as it will not adjust to the ambient temperature. Only qualified personnel can install the compressor and put it into operation for the first time. The installer shall train the operating personnel in the use and routine maintenance of the equipment. Installation and training of personnel should be acknowledged by the installer s signature on the installation certificate. Prior to start-up, the four screws for transport stabilization must be removed. If the compressor is switched on without removing the stabilizers, the compressor could be permanently damaged. The compressor does not contain a backup power supply. Never block the air intake filter on the backside or the vent outlets on the top of the equipment. If the compressor is equipped with a main source of air, the standby air source must be available. ANY MODIFICATION OF THIS EQUIPMENT IS FORBIDDEN! If this equipment is used nearby other instruments, the equipment must be observed in order to verify normal operations in the configuration it will be used. Instruments may be affected electro-magnetically! BEFORE FIRST USE REMOVE PROTECTIVE COVER OF THE SWITCH! 10 NP-DK50 DS-19_

12 OPERATION Removal of transport stabilizers On the bottom of the unit are four M6 stabilizing screws that must be removed before start-up. They are marked with a red warning washer. Wheel installation Please retain the stabilizing screws for future transport of the compressor. Wheels must be installed following the figure below for versions of the compressor with wheels. Compressed air connection The medical compressor is equipped with quick couplings WALL (10) and OUT (9) on the rear of the cabinet. Connect the pressure hose from the given equipment/respiration equipment to the quick coupling OUT (9) -outlet compressed air. Connect the compressed air line from the central distribution line o the quick coupling WALL (10) -inlet compressed air. Air from the distribution system is automatically connected through the compressor to the OUT outlet port. In this configuration, the compressor serves as a backup source of compressed air. If the air pressure from the central distribution system is reduced, the compressor automatically switches on and there is no interruption in the supply of continuously pressurized air at the outlet of the compressor. Please note that the air supply from the central distribution line entering the compressor must be medical grade air (particulate size, humidity.) The compressor does not modify the air from the central distribution line. The hose connecting the compressor to the respiration equipment must not pass through a cold environment i.e. placed on the ground. It should be as short as possible with no kinks (this may cause water to condense inside the hose). NP-DK50 DS-19_

13 OPERATION Electrical connection The compressor comes with a plug containing an appropriate protective contact (ground.) Adhere to local electrical regulations. The voltage and frequency of the mains must comply with the specifications on the data label. The electrical cord must not be stressed or have any tension exerted upon it, and must always be free. The socket must be accessible for safety reasons so that the equipment can be safely disconnected from the power supply in case of an emergency. The relevant current circuit must be protected. Connection of the ground connection (12) to other equipment must adhere to local electrical regulations. Fasten the electrical cord through the holder (13). First operation Make sure that the stabilizing screws used during transport were removed. Check that the connection to the compressed air supply is correct. Check for proper connection to the main power supply. Switch on the pressure switch (11) to position I. After the compressor is put into operation, it shall work in one of the following modes depending upon the pressure level in the central distribution and upon air consumption. STANDBY When there is sufficient pressure in the central air distribution line, the main switch is on and the POWER (8) indicator is on, the compressor is idle. The device operates as a standby source of air as it checks the pressure in the central air distribution line and, if the pressure falls, the compressor switches on. When pressure is low in the central air distribution line, or if the device is not connected to the central distribution line, the compressor is running. If there is no air consumption at the outlet, the device switches to STANDBY mode. When air consumption resumes, the compressor automatically switches on. The working pressure in the air tank when the compressor is running is maintained between the high and low pressure limits by the control unit. After the high working pressure limit is reached, the compressor output is connected to the exhaust (bypass) and the compressor stops supplying compressed air to the air tank until as long as the pressure in the tank does not drop below the low pressure limit. During operation, the device drains the trapped condensed water from pneumatic circuits via automatic filter separators into a separate tank. 12 NP-DK50 DS-19_

14 OPERATION Important note: If compressor equipped with set of membrane dryer ( art. nr.: ) and compressor is not connected to WALL ( central air supply ), the compressor does not switch into STAND BY. In order to maintain the membrane dryer unit active the dryer unit requires a small constant flow of compressed air. Compressor works in RUN mode only. The compressor stops and starts only when it is switched off and on manually by power switch. Accessories If compressor equipped with set of membrane dryer ( art. nr.: ) and compressor is connected to WALL ( central air supply ), the compressor works in complete mode operation, including STAND BY mode. Trolley SD 30 (24) The trolley accommodates the compressor, a fan and a humidifier. Large casters allow for mobility and braking, guided by means of an ergonomic handle. A wide base ensures the stability of the entire assembly. Specifications Supply No.: Dimensions: 535x575x1070 Maximal load-carrying capacity with load in the upper plate axis (1): Trolley without compressor - Trolley with compressor - 25kg 30kg The manufacturer is not liable for any damage resulting from excessive loads on the equipment! The supplier is obliged to ensure the acceptability of a load delivered by a supplied accessory. It is forbidden to lean or press against an installed accessory for support! The equipment must be lifted when travelling over an obstacle! Supporting equipment must be disassemble before transport! The maximum load on the upper trolley plate is 30 kg! Humidifier holder (25) This clamp is used to attach the Fischer & Paykel humidifier to the trolley in its proper position. Supply No NP-DK50 DS-19_

15 OPERATION PERSONNEL In case of emergency, switch the equipment off at the switch and pull out the main power plug. Switching the compressor on The compressor is switched on at the main power switch (11) by putting it in position "I". Switching on is signaled by the green indicator (8). Running the compressor The green indicator POWER (8) is lit up during operation. The display shows the value of outlet pressure with accuracy ± 5% in BAR or PSI units. An indicator is lit on the display next to the relevant unit. Ask the service staff member to change the units that are shown if necessary. 115V version - After pressing the TIME (6) button, the display shows the number of hours in operation. 230V version - After pressing the TIME (6) button, the display shows the number of hours in operation. The compressor operating hours since the last service work are displayed by pressing the button for about 2 seconds. The calculated running interval is set to a coefficient of 1.0 if the compressor is supplying compressed air to the air tank. The calculated coefficient is 0.3 in BYPASS mode. The DRYING (4) indicator displays the drying status. Green indicates satisfactory drying; yellow indicates unsatisfactory drying. If the yellow indicator DRYING (4) stays on, make sure that air consumption from the compressor does not exceed outlet flow according to specification. If air consumption is within normal parameters, contact a service centre. A decrease in outlet pressure is indicated by the alarm PRESSURE (2) which sounds an alarm and illuminates the yellow indicator. The alarm is activated if the outlet pressure does not reach the required level and in the interval after the compressor is turned on until it reaches the required pressure. If the alarm stays on, make sure that the air consumption does not exceed outlet flow according to specification. If air consumption is within normal parameters, contact a service centre. A cooling failure is indicated by the alarm TEMP (3) which sounds an alarm and illuminates the yellow indicator. The device must be immediately disconnected from the electrical mains and cooled down. Cooling failure activation may indicate that the vent holes were covered, the filter in the bottom part of the compressor is contaminated or the compressor is in environment with higher temperature. If none of these circumstances apply, a malfunction has occurred and service is required. The alarm MAINS (5) is activated upon the interruption in the power supply to the compressor. Illumination of the yellow indicator BATTERY (7) indicates a low battery. The battery is charged automatically during equipment operation. If the yellow control light does not turn off after 24 hours of the equipment operation, it is 14 NP-DK50 DS-19_

16 OPERATION necessary to change the battery. The battery powers the MAINS (5) alarm and has no impact on other functions of the device. Entrust an authorized service provider with its replacement. Replace the battery with an identical replacement - NiMH 9V 200mAh. Used batteries cannot be disposed of as household waste, they must be collected separately. The condensed liquid drains into a separate tank (14) at the back of the equipment. When the tank fills up, it must be emptied. Close the plug located on the neck of the vessel before moving any vessel containing a liquid! Cleaning and replacing the filters At least once a week take out and clean the suction filter (15) located on the back side. Wash the filter in warm soapy water, rinse thoroughly and allow it to dry. Insert the clean filters so that the intake openings are completely covered by the filters. Cleaning the compressor To clean the compressor, use a detergent that contains no abrasives, chemical solvents or other corrosive agents. 5. MAINTENANCE REPAIRS AND SERVICE Warranty and extended warranty repairs are to be completed by the manufacturer or a service provider authorized by the manufacturer. The manufacturer reserves the right to modify the equipment in any way that will not alter the function or the operation of the equipment. Only a qualified technician or the Customer Service Department of the manufacturer may perform repairs that go beyond routine maintenance. Use only spare parts and accessories approved by the manufacturer. Prior to any maintenance or repairs, switch off the compressor and disconnect it from the mains (pull out the main power plug). Cover removal - Unscrew the 6 screws from the rear cover - Disconnect the grounding wire - Remove the rear cover - Disconnect the wiring connector for the display and pull the wiring out from the opening in the frame NP-DK50 DS-19_

17 MAINTENANCE - Unscrew the 4 screws from the rear of the main cover and 2 screws from the rear part of the rail - Disconnect the grounding wire - Remove the main cover - Reassemble using the opposite order MAINTENANCE SCHEDULE Notice! The operating entity is obliged to ensure that all tests of the equipment are carried out repeatedly at least once within every 24 months (EN 62353) or in intervals as specified by the applicable national legal regulations. A report must be prepared on the results of the tests (e.g.: according to EN 62353, Annex G), including the measurement methods used. Maintenance Page Time interval To be performed by Clean air intake filter 13 At least once a week Staff Safety valve check 15 Once per year Qualified expert Replace filters in filter 16 Every 4000 hours Qualified expert Test the tightness of joints and inspect the equipment Replace piston complete with piston rings, O-rings and bearing 15 After two years Qualified expert Service documentation Every 8000 hours Qualified expert Replace suction filter 17 Every 8000 hours Qualified expert Perform Repeated Test according to EN x 2 years Qualified expert Service interval signalization Safety valve check Once 4000 operating hours have been reached, the value 4000 starts to appear as the outlet pressure from the equipment, alternating with the actual outlet pressure value. They alternate about every 2 seconds. Once this information appears, the operator is obliged to secure service work for the equipment. The safety valve is adjusted to 7 bar by the manufacturer, then tested and marked. It must not be readjusted. 16 NP-DK50 DS-19_

18 MAINTENANCE Only allow the safety valve freely puff for a short period of time. Never use the safety valve to release pressure in the air tank. This could damage the safety valve. Check tightness of joints and inspect the equipment Test for leakage: Disconnect the outlet hose from the quick coupling OUT (9); compressed air consumption will stop. Pressurize the air tank by releasing some air via a connected device. With the compressor off, wait at least 10 minutes before checking the pressure level. If the pressure has dropped, use soapy water to find the leaky joint. Start with the joints outside the case, and then test the ones inside the case after removing the covers. Tighten or re-seal joints as necessary. Inspect the equipment: Check the status of the compressor motor for balanced operation or noise. Check the condition of the hangers above the pump. Check fan functionality. Check the condition of the filter. With regular operation, condensate from the filter (19) drains automatically. Verify this function by comparing the level of condensate in the bottle to the scale line indicating the maximum level. If the level of condensate is above the scale line, replace the faulty parts. Examine the pump for: - Defects in the crankcase - Free movement of the crank shaft If necessary, replace any faulty parts. Replacing filters elements Before beginning, evacuate all compressed air from the tank, reducing the tank pressure to zero and disconnect the equipment from the power mains. NP-DK50 DS-19_

19 MAINTENANCE Unscrew the cover and pull it out using the enclosed wrench (26). Unscrew the filter holder. Replace the filter and screw the filter holder into place. Screw the cover back in place. 26 Spare filtration pads: Bronze (40 μm) (19a) AF20P-060S-7-40B Item Plastic (5 μm) (19b) AF20P-060S Item If the water release system becomes clogged, disassemble the release valve (f), clean the outlet, remove the float (b) with a lever mechanism (c, d, and e) from the tank, clean all components with a soap solution and then reassemble. Setting outlet air pressure To unlock the control button of the regulator (20), raise it slightly and rotate it to set the demand outlet pressure. After setting the pressure, lock the control button of the regulator by pushing it down. Cleaning the pressure regulator Set the pressure to the minimum position Remove the plug (1) Rotate and remove the latch (2) Remove the line from the valve (3) and the valve (4), then clean the valve seat and the o-ring Re-install the components in the following order: (4), (3), (2) and (1) 18 NP-DK50 DS-19_

20 MAINTENANCE Replacing the inlet filter (21) Unlock the cover and pull it out. Replace the filter Lock the cover Spare part: Intake filter 05W POLYESTER, Item Stabilizing the compressor before shipping Before shipping, the compressor must be stabilized to prevent movement. Prior to fixation, it is necessary to disassemble the plastic cover. The air pump must be fixed to the base using the four original M6 screws (see picture). Assemble the plastic cover. SHUT-DOWN If the compressor is not going to be used for a long period of time, disconnected it from the main power supply and release the pressure in the air tank. EQUIPMENT DISPOSAL Disconnect the equipment from the main power supply. Release the pressure in the air tank. Dispose of the equipment according to local regulations. Parts used in this product have no negative impact on the environment when disposed of properly. BATTERY DISPOSAL No battery may be disposed with common household waste. Dispose of non-functional batteries at suitable collection sites. NP-DK50 DS-19_

21 TROUBLESHOOTING 6. TROUBLESHOOTING Prior to servicing the equipment, reduce the pressure in the air tank to zero and disconnect the equipment from the main power supply. Only trained service personnel can perform the activities listed in the troubleshooting guide. PROBLEM POTENTIAL CAUSE SOLVING COMMON PROBLEMS There is pressure in the air tank In STANDBY mode, the compressor starts when pressure decreases Switched off main breaker in distribution system Check supply No main power voltage Replace a defective fuse Compressor does Loose wire terminal tighten not start Power cord defective replace DRYING indicator lights yellow permanently PRESSURE alarm is activated permanently TEMP alarm is activated Compressor is noisy (knocking, metal noises) Water coming out of outlets Compressor malfunction Interrupted winding of motor, damaged thermal protection Defective capacitor Jammed piston or other part Leakage of air from pneumatic distribution system Large consumption of compressed air Worn out piston rings Dirty air suction filter Dirty air intake filter Leakage of air from pneumatic distribution system Large consumption of compressed air Worn out piston rings Dirty air suction filter Dirty air intake filter Dirty filter inserts of filter Dirty air blow down filter Covered vent holes Cooling fans don t work Unit is hot, unventilated area Damaged piston bearing or bearing in motor Loose (cracked) belt of the air pump hanger Dirty water trap in filter and filter regulator Failure of control unit Replace motor Replace capacitor Replace damaged parts Inspect pneumatic distribution system seal loose connection Do not exceed max. flow (see Technical data) Replace worn out piston rings Replace the dirty air suction filter Clean or replace the dirty air intake filter Inspect the pneumatic distribution system seal loose connection Do not exceed max. flow (see Technical data) Replace worn out piston rings Replace the dirty air suction filter Clean or replace the dirty air intake filter Replace the dirty inserts Clean or replace the dirty air blow down filter Uncover vent holes Replace fans Relocate unit Replace damaged bearing Replace damaged hanger Clean or replace the water trap Adjust using service software 20 NP-DK50 DS-19_

22 SPARE PARTS 7. SPARE PARTS Air intake filter (15 ) Filtration inserts (19a) Filtration inserts (19b) Fuse version 230V T6.3A V, 120V T10A Insertion DISS 1160-A Suction filter 05W POLYESTER NP-DK50 DS-19_

23 ELECTRIC AND PNEUMATIC DIAGRAMS 8. ELECTRIC AND PNEUMATIC DIAGRAMS WIRING DIAGRAM 1/N/PE ~ 230/120/100 V Hz ELECTRIC OBJECT OF 1st CAT. B TYPE YV DISPLAY ST? 14 U N Valve 1 14 Display X2 N - + N N U U U ~ Motor Fan 9 V battery 3rd contact X1 Q M XC 1 M EV1 EV2 U PE N Wiring diagram DK50 DS Mark Name Mark Name X1, X2 EV1, EV2 YV Q Sockets on PCB Fan Solenoid valve Switch M ST XC Electric motor Thermal sensor Socket with fuses 22 NP-DK50 DS-19_

24 ELECTRIC AND PNEUMATIC DIAGRAMS PNEUMATIC DIAGRAM OUT 3 2 T WALL 5 12 P1 P Intake filter 2. Compressor 3. Solenoid valve 4. Return valve 5. Cooler 6. Filter with water trap 7. Pressure regulator 8. Air outlet 9. Air intake 10. Air tank 11. Safety valve 12. Shuttle valve NP-DK50 DS-19_

25

VERTICAL AIR COMPRESSORS

VERTICAL AIR COMPRESSORS VERTICAL AIR COMPRESSORS MODEL NO: VE15C150, VE18C150, VE25C150 PART NO: 2226010, 2226020, 2226025 OPERATION & MAINTENANCE INSTRUCTIONS LS0715 INTRODUCTION Thank you for purchasing this CLARKE Vertical

More information

VERTICAL AIR COMPRESSORS

VERTICAL AIR COMPRESSORS VERTICAL AIR COMPRESSORS MODEL NO: VE11C150, VE15C150, VE18C150 PART NO: 2226005, 2226000, 2226015 OPERATION & MAINTENANCE INSTRUCTIONS LS0615 INTRODUCTION Thank you for purchasing this CLARKE Vertical

More information

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST OIL-LESS TYPE IMPORTANT: PLEASE READ CAREFULLY BEFORE STARTING OPERATIONS. THE CONTENTS ARE FOR GENERAL INFORMATION OF ALL THE SIMILAR MODELS. Record

More information

200 PSI FAST-FILL AIR SOURCE KIT

200 PSI FAST-FILL AIR SOURCE KIT 200 PSI FAST-FILL AIR SOURCE KIT 55% Duty Compressor on 2.0 Gallon Air Tank PART NO. 20007 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of

More information

200 PSI COMPRESSORS - MODEL NUMBERS

200 PSI COMPRESSORS - MODEL NUMBERS 200 PSI COMPRESSORS - MODEL NUMBERS 380C AIR COMPRESSOR KIT PART NO. 38033 480C AIR COMPRESSOR KIT PART NO. 48043 380C 480C IMPORTANT: It is essential that you and any other operator of this product read

More information

100C Air Compressor Kit

100C Air Compressor Kit 10010 100C Air Compressor (standard mounting bracket, CE Spec) 10014 100C Air Compressor (no leader hose or check valve, CE Spec) 10016 100C Air Compressor (with Omega Bracket, CE Spec) IMPORTANT: It is

More information

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1. 2 GALLON TWIN STACK AIR COMPRESSOR Model: 9526 DO NOT RETURN TO STORE. Please CALL 800-348-5004 for parts and service. CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or

More information

200 PSI HIGH-FLOW AIR SOURCE KIT

200 PSI HIGH-FLOW AIR SOURCE KIT 200 PSI HIGH-FLOW AIR SOURCE KIT 50% Duty Compressor on 2.0 Gallon Air Tank PART NO. 20008 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of

More information

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP 50-24 General User and Maintenance Instructions Silentaire Technology 8614 Veterans Memorial Dr. Houston, TX 77088 800-972-7668 Fax 832-327-0669 www.silentaire.com

More information

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight Technical Specifications Operating Instructions Maintenance Information Troubleshooting Guide Parts Diagrams AC1810 / AC1810-A THE EVOLUTION OF PERFECTION CAUTION: Before attempting to use or service this

More information

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock or Electrocution: MODEL NUMBER: 20008 200 PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank IMPORTANT: It is

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock: - Do not disassemble. Do not attempt repairs or modifications. Refer to qualified service agencies for all service and repairs.

More information

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO 420C AIR COMPRESSOR KIT PART NO. 42042 460C AIR COMPRESSOR KIT PART NO. 46043 420C 460C IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this

More information

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO 97C COMPRESSOR KIT 12V PART NO. 00097 97C COMPRESSOR KIT 24V PART NO. 02497 98C COMPRESSOR KIT PART NO. 00098 97C 98C IMPORTANT: It is essential that you and any other operator of this product read and

More information

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE MODEL NUMBER: M20005 AIR SOURCE KIT 30% Duty Compressor on 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE USER MANUAL IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock

More information

444C DUAL PERFORMANCE VALUE PACK

444C DUAL PERFORMANCE VALUE PACK (Chrome) PART NO. 44432 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product. SAVE THIS MANUAL

More information

SILENTAIRE TECHNOLOGY

SILENTAIRE TECHNOLOGY SILENTAIRE TECHNOLOGY 8614 Veterans Memorial. Houston, Texas 77088 832/327-7452 800/972-7668 Fax: 832/327-0668 E-mail: silentaire@silentaire.com Thank you and congratulations on the purchase of your OILLESS

More information

OC4000 USER'S GUIDE I O OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY. by Supera Anesthesia Innovations GLOSSARY OF SYMBOLS. : ON (power switched on)

OC4000 USER'S GUIDE I O OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY. by Supera Anesthesia Innovations GLOSSARY OF SYMBOLS. : ON (power switched on) by Supera Anesthesia Innovations USER'S GUIDE OC4000 OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY I O : ON (power switched on) : OFF (power switched off) : Class II protection : Do not expose to open flames

More information

SF SERIES CNG COMPRESSOR MODEL HF-4MH. 4 Nm3/Hour Displacement OPERATION MANUAL

SF SERIES CNG COMPRESSOR MODEL HF-4MH. 4 Nm3/Hour Displacement OPERATION MANUAL SF SERIES CNG COMPRESSOR MODEL HF-4MH 4 Nm3/Hour Displacement OPERATION MANUAL 1 Content 1. General Description...3 2. Main technical parameters...3 3. Structural principle...4 3.1Main structure...4 3.2Compressor

More information

24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS10/13

24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS10/13 24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: 2244030 OPERATION & MAINTENANCE INSTRUCTIONS LS10/13 INTRODUCTION Thank you for purchasing this product. Before attempting to use this product,

More information

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO 400H HARDMOUNT AIR COMPRESSOR KIT PART NO. 40042 450H HARDMOUNT AIR COMPRESSOR KIT PART NO. 45042 400H 450H IMPORTANT: It is essential that you and any other operator of this product read and understand

More information

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO 250C-IG COMPRESSOR KIT 12V PART NO. 25050 250C-IG COMPRESSOR KIT 24V PART NO. 25058 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual

More information

400C & 450C DUAL PERFORMANCE VALUE PACKS

400C & 450C DUAL PERFORMANCE VALUE PACKS (Chrome) PART NO. 40013 (Silver) PART NO. 45012 (Chrome) PART NO. 45013 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before

More information

OPERATION MANUAL NTF-15

OPERATION MANUAL NTF-15 OPERATION MANUAL NTF-15 Nitrogen Tire Filling Valve Stem Caps (Qty=200) Order P/N 436075 RTI Technologies, Inc 10 Innovation Drive York, PA 17402 800-468-2321 www.rtitech.com 035-81235-00 (Rev B) TABLE

More information

ORB-400 BUBBLE/HAZE MACHINE. Item ref: UK User Manual

ORB-400 BUBBLE/HAZE MACHINE. Item ref: UK User Manual ORB-400 BUBBLE/HAZE MACHINE Item ref: 160.462UK User Manual Caution: Please read this manual carefully before operating Damage caused by misuse is not covered by the warranty Introduction Thank you for

More information

SC505 Sof Care Inflator. Operating Instructions and Service Manual

SC505 Sof Care Inflator. Operating Instructions and Service Manual SC505 Sof Care Inflator Gaymar Industries, Inc. 10 Centre Drive Orchard Park, NY 14127 Toll Free +1 800.828.7341 + 1 716.662.2551 Fax +1 800.993.7890 Outside USA +1 716.662.8636 Outside USA Fax +1 716.662.0730

More information

SILENTAIRE TECHNOLOGY

SILENTAIRE TECHNOLOGY SILENTAIRE TECHNOLOGY General User and Maintenance Instructions Thank you and congratulations on the purchase of your PANTHER, the leader in the industry of portable air compressors. The PANTHER is built

More information

OC4000 USER'S GUIDE I O OXYGEN CONCENTRATORS OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY GLOSSARY OF SYMBOLS. : ON (power switched on)

OC4000 USER'S GUIDE I O OXYGEN CONCENTRATORS OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY GLOSSARY OF SYMBOLS. : ON (power switched on) OXYGEN CONCENTRATORS USER'S GUIDE OC4000 OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY I O : ON (power switched on) : OFF (power switched off) : Class II protection : Do not expose to open flames GLOSSARY

More information

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO 250C-IG COMPRESSOR KIT 12V PART NO. 25050 250C-IG COMPRESSOR KIT 24V PART NO. 25058 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual

More information

200L BELT DRIVEN AIR COMPRESSOR

200L BELT DRIVEN AIR COMPRESSOR 200L BELT DRIVEN AIR COMPRESSOR MODEL NO: BOXER 14/200 PART NO: 2245215 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS0118 ISS 4 INTRODUCTION Thank you for purchasing this CLARKE 200L Belt

More information

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury. 2 GALLON AIR COMPRESSOR Model: 7517 DO NOT RETURN TO STORE. Please CALL 800-348-5004 for parts and service. CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials

More information

OPERATION MANUAL NTF-60 Plus

OPERATION MANUAL NTF-60 Plus OPERATION MANUAL NTF-60 Plus Nitrogen Tire Filling Valve Stem Caps (Qty=200) Order P/N 436075 RTI Technologies, Inc 10 Innovation Drive York, PA 17402 800-468-2321 www.rtitech.com 035-81264-00 (Rev A)

More information

24L AIR COMPRESSOR MODEL NO: TIGER 8/260 PART NO:

24L AIR COMPRESSOR MODEL NO: TIGER 8/260 PART NO: 24L AIR COMPRESSOR MODEL NO: TIGER 8/260 PART NO: 1499490 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS0918 - ISS 2 INTRODUCTION Before attempting to use this product, please read this

More information

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator. PRS(TC)4,8 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to

More information

AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: CHAMP 3 PART NO: LS0115

AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: CHAMP 3 PART NO: LS0115 AIR COMPRESSOR MODEL NO: CHAMP 3 PART NO: 2225222 OPERATION & MAINTENANCE INSTRUCTIONS LS0115 INTRODUCTION Thank you for purchasing this CLARKE Air Compressor. Please read this manual fully before use

More information

3/8" Dr. Air Butterfly Impact Wrench

3/8 Dr. Air Butterfly Impact Wrench 8192106 3/8" Dr. Air Butterfly Impact Wrench Owner s Manual Read and understand all instructions before use. Retain this manual for future reference. Specifications Construction: Polished aluminum and

More information

Budget Range Operators Handbook

Budget Range Operators Handbook Budget Range Operators Handbook BAMBI AIR COMPRESSORS LTD 152 Thimble Mill Lane Heartlands Birmingham B7 5HT United Kingdom Tel: 0121 322 2299 Fax: 0121 322 2297 Email: sales@bambi-air.co.uk www.bambi-air.co.uk

More information

OPERATING AND MAINTENANCE MANUAL GOLD LINE EXTRACTION CLEANERS M14-M26

OPERATING AND MAINTENANCE MANUAL GOLD LINE EXTRACTION CLEANERS M14-M26 OPERATING AND MAINTENANCE MANUAL GOLD LINE EXTRACTION CLEANERS M14-M26 Made For: Spitwater Australia Pty Ltd 953 Metry St North Albury, NSW, Australia WARNING: FAILURE TO FOLLOW OPERATING, SAFETY AND MAINTENANCE

More information

Code AWC20HP Air Compressor

Code AWC20HP Air Compressor Code 951816 AWC20HP Air Compressor Index of Contents Index of Contents 02 Declaration of Conformity 02 What s Included 03 Safety Precautions 03 Specifications (AWC20HP Air Compressor) 04 Assembly Instructions

More information

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES EXTREME SERIES PART NO. 45043 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product. SAVE THIS

More information

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS 18 GAUGE 1-1/4 INCH BRAD NAILER Model: 7611 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement, or other masonry.

More information

RAM 4021-DPX Operation Manual

RAM 4021-DPX Operation Manual RAM 4021-DPX Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS ABL 4021-DPX / RAM 4021-DPX For Your Safety... 3 Description... 3 Setup Mode... 4 Lights/Alarms... 4 Operation...

More information

EGL-12 OIL-LESS COMPRESSOR

EGL-12 OIL-LESS COMPRESSOR Operator s Manual 2016 EGL-12 OIL-LESS COMPRESSOR EGL-12 / 2HP OIL-LESS COMPRESSOR INSTALLATION QUESTIONS? 1-800-240-5677 SIERRA DENTAL PRODUCTS, LLC. 1953 W. Gulf to Lake Hwy. Lecanto, FL 34461 www.dentalvacuums.com

More information

24L AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: RANGER 7/240 PART NO: LS0913

24L AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: RANGER 7/240 PART NO: LS0913 24L AIR COMPRESSOR MODEL NO: RANGER 7/240 PART NO: 2242000 OPERATION & MAINTENANCE INSTRUCTIONS LS0913 INTRODUCTION Thank you for purchasing this CLARKE 24L Air Compressor. Please read this manual fully

More information

120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank

120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank 120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank PART NO. 20003 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of

More information

Manual Actuated Boiler Blowdown Valves

Manual Actuated Boiler Blowdown Valves Manual Actuated Boiler Blowdown Valves Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Operation 5. Maintenance 6. Spare parts p.1 1. Safety

More information

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289 3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS Item #31289 The EASTWOOD 3 GALLON, OILLESS PANCAKE COMPRESSOR, with an Integral Air Regulator, efficiently supplies all compressed air requirements for

More information

Use this key to determine which sections of this Product Manual apply to your job.

Use this key to determine which sections of this Product Manual apply to your job. R710 Product Manual Contents Warnings and Important Information 3 Recommended Use 4 Product Information 5 Technical Data 5 Before & During Every Transfer 6 Inspection 6 SoloLift Scale (optional) 6 SoloVest

More information

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL ATD-8402 90LB PRESSURE BLASTER INSTRUCTION MANUAL SAVE THESE INSTRUCTIONS SAFETY INSTRUCTIONS FOR SANDBLASTER 1. Before opening the tank release the air pressure on the sand tank. To do this, turn off

More information

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES 450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES PART NO. 45053 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing

More information

Technical Information

Technical Information Technical Information Installation, Operation, Installation, Operation and Maintenance and Maintenance Manual Manual Balston Model 75700-K728 Nitrogen Generator Figure 1-75700-K728 Overall Dimensions These

More information

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator. RS(H)10,15 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to

More information

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only) 42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) 42047 Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only) 45052 Constant Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor

More information

Freedom8 ShoeBox Compressor Manual

Freedom8 ShoeBox Compressor Manual Freedom8 ShoeBox Compressor Manual Warning!! This product is not a toy! Use or misuse can cause severe injury or death! Use only with adult supervision. This unit is only to be used with tanks, hoses and

More information

Right-Angle Tube Roller Model

Right-Angle Tube Roller Model SPECIFICATIONS Model no. Free Speed (RPM) Throttle Rotation Max. Torque Ft-Lb Air Pressure psi Air Inlet Hose Air Flow @Free Speed Spindle Weight 909-1700 95 Lever type Reversible 240 90 1/2 NPT 1/2 I.D.

More information

24L AIR COMPRESSOR MODEL NO: TIGER 11/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

24L AIR COMPRESSOR MODEL NO: TIGER 11/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13 24L AIR COMPRESSOR MODEL NO: TIGER 11/250 PART NO: 2244010 OPERATION & MAINTENANCE INSTRUCTIONS LS01/13 INTRODUCTION Thank you for purchasing this product. Before attempting to use this product, please

More information

50L BELT DRIVEN AIR COMPRESSOR

50L BELT DRIVEN AIR COMPRESSOR 50L BELT DRIVEN AIR COMPRESSOR MODEL NO: BOXER 14/50P PART NO: 2245200, 2245203 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS0118 - ISS 4 INTRODUCTION Thank you for purchasing this CLARKE

More information

MoveRoll Conveyor Operating and Maintenance Manual

MoveRoll Conveyor Operating and Maintenance Manual MoveRoll Conveyor Operating and Maintenance Manual 1. Read this first! This manual contains information for protection of personnel in the roll handling area from possible injury and/or equipment damage.

More information

RAM 4021 Operation Manual

RAM 4021 Operation Manual RAM 4021 Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021 For your safety...3 Description...3 Set-up mode...4 Annunciator lights/alarms...4 Operation...5 Calibration...6

More information

100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13 100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: 2244025 OPERATION & MAINTENANCE INSTRUCTIONS LS01/13 INTRODUCTION Thank you for purchasing this product. Before attempting to use this product, please

More information

Columbus Instruments

Columbus Instruments 0215-003M Portable O 2 /CO 2 /CH 4 Meter User s Manual Columbus Instruments 950 NORTH HAGUE AVENUE TEL:(614) 276-0861 COLUMBUS, OHIO 43204, USA FAX:(614) 276-0529 1 www.colinst.com TOLL FREE 1-800-669-5011

More information

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL 2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL Model: 52024 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement,

More information

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS 18 GAUGE 2 INCH BRAD NAILER Model: 7555 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement, or other masonry.

More information

CUT OFF TOOL MODEL: CAT113

CUT OFF TOOL MODEL: CAT113 CUT OFF TOOL MODEL: CAT113 Part No: 3120135 ASSEMBLY & INSTRUCTION MANUAL LS0309 INTRODUCTION Thank you for purchasing this CLARKE product Before attempting to use the product, it is essential that you

More information

Model PSI Compressor with 3-Gallon Air Tank 12VDC

Model PSI Compressor with 3-Gallon Air Tank 12VDC Model 6350 150 PSI Compressor with 3-Gallon Air Tank 12VDC IMPORTANT: It is essential that you and any other operator of this product read and understandd the contents of this manual before installing

More information

AIR HAMMERS MODEL NO: CAT138/CAT139 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: / GC064

AIR HAMMERS MODEL NO: CAT138/CAT139 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: / GC064 AIR HAMMERS MODEL NO: CAT138/CAT139 PART NO: 3120152 /3120153 OPERATING & MAINTENANCE INSTRUCTIONS GC064 INTRODUCTION Thank you for purchasing this CLARKE Air Hammer. Before attempting to use this product,

More information

e.do Gripper Safety requirements, technical features and assembly and integration instructions

e.do Gripper Safety requirements, technical features and assembly and integration instructions e.do Gripper Safety requirements, technical features and assembly and integration instructions Requirements, technical features and instructions for safe installation and use of the e.do Gripper. CR00758190-en_00/2018.05

More information

Vapotherm Q50 Compressor. Instructions for Use

Vapotherm Q50 Compressor. Instructions for Use Vapotherm Q50 Compressor Instructions for Use Contents Quick Start Guide...2 Intended Use...3 Indications, Warnings and Cautions...4 Primary Indications...4 Contraindications...4 Warnings and Cautions...4

More information

RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL

RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL DESCRIPTION 1. No mar 2. No mar tip 3. Housing grip 4. Trigger 5. Air inlet 6. Air inlet plug 7. Plastic board Important! It is essential that you read the

More information

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS FILTER REGULATORS MODEL NO: CAT155 & CAT156 PART NO: 3120169 & 3120170 FITTING & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC0117 INTRODUCTION Thank you for purchasing this CLARKE Filter/Regulator.

More information

/ Air Line Kit AL - M1202. / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651

/ Air Line Kit AL - M1202. / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651 / Air Line Kit AL - M1202 / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651 002 1 Thank you for purchasing the Air Line Kit " AL - M1202 ". This Air Line Kit is designed to adjust the air supply

More information

Welcome to the Specialized Medical Services Respiratory training webinar series!

Welcome to the Specialized Medical Services Respiratory training webinar series! Welcome to the Specialized Medical Services Respiratory training webinar series! SMS is your Long Term Care (LTC) facility single source for oxygen, medical equipment, respiratory care services and supplies

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock or electrocution: - Do not disassemble. Do not attempt repairs or modifications. Refer to qualified service agencies for all service

More information

D10S/D20S Wall/Post Mount Inflator Quick Start Manual

D10S/D20S Wall/Post Mount Inflator Quick Start Manual PART NUMBER SERIAL NUMBER D10S/D20S Wall/Post Mount Inflator Quick Start Manual Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product

More information

Operating Instructions Part No

Operating Instructions Part No DIGITAL AUTOMATIC TYRE INFLATOR Operating Instructions Part No. 11.0578 Thank you for selecting this Jamec Pem Automatic Tyre Inflator. Please read this manual before carrying out any installation or service

More information

Installation, Operation, and Maintenance Manual Parker Balston Model N2-04 Nitrogen Generator

Installation, Operation, and Maintenance Manual Parker Balston Model N2-04 Nitrogen Generator Installation, Operation, and Maintenance Manual Parker Balston Figure 1 - N2-04 Nitrogen Generator These instructions must be thoroughly read and understood before installing and operating this product.

More information

RAM Operation Manual

RAM Operation Manual RAM 4021-1 Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021-1 For Your Safety... 2 Description... 2 Setup Mode... 3 Lights/Alarms... 3 Operation... 4 Calibration...

More information

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies We reserve the right to make technical changes without notice. Technische Änderungen vorbehalten. Sous réserve de modifications techniques.

More information

AIR INLINE METAL SHEAR

AIR INLINE METAL SHEAR AIR INLINE METAL SHEAR ASSEMBLY and OPERATING INSTRUCTIONS 3491 Mission Oaks Blvd. / Camarillo, CA 93011 Copyright 1997 by Harbor Freight Tools. All rights reserved. No portion of this manual or any artwork

More information

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10 LK product no: PCS 1-10 Article no: 74503 Revision:8 Article no: 74503 Revision: 8 2 (23) Contents 1. General information... 5 2. Safety precautions... 5 2.1 Significance of symbols... 5 2.2 Explanatory

More information

USER MANUAL. JET TST and JET TST S.

USER MANUAL. JET TST and JET TST S. USER MANUAL JET TST and JET TST S www.sisteven.com Types of Jet fans: JET TST UNI: Impulse axial fan single direction JET TST S UNI: Impulse axial fan single direction (short case) JET TST REV: Impulse

More information

accidents which arise due to non-observance of these instructions and the safety information herein.

accidents which arise due to non-observance of these instructions and the safety information herein. 3 GALLON PANCAKE COMPRESSOR Model: 50959 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement, or other masonry.

More information

RASP RX3 Feed UnitTM SPONGE-JET USER MANUAL. Sponge-Jet, Inc. (USA) 14 Patterson Lane Newington, NH

RASP RX3 Feed UnitTM SPONGE-JET USER MANUAL. Sponge-Jet, Inc. (USA) 14 Patterson Lane Newington, NH SPONGE-JET RASP RX3 Feed UnitTM USER MANUAL Sponge-Jet, Inc. (USA) 14 Patterson Lane +1-603-610-7950 Newington, NH 03801 www.spongejet.com Sponge-Jet RASP RX3 User Manual - REV A / DOC: MKT-014-ENG SPONGE-JET

More information

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR MODEL NUMBER: 45043-450P-A AUTOMATIC PORTABLE COMPRESSOR IMPORTANT: It is essential that you and any other operator of the product read and understand the contents of this manual before installing and

More information

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER Operation Manual - PN 0017946001 A MENSOR MODEL 73 SHOP AIR BOOSTER Mensor Model 73 Shop Air Booster System (750 psi Version) April 23, 2012 Trademarks / Copyright Mensor is a registered trademark of Mensor

More information

Oxygen Dialflow Meter. Instructions for Use

Oxygen Dialflow Meter. Instructions for Use Oxygen Dialflow Meter Instructions for Use 702-0031.9 May 2014 1. Symbols Warning! Caution! Indicates a potentially hazardous situation which, if not avoided, could result in personal injury to the user

More information

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions RAM 4021 Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021 For Your Safety... 2 Description.... 2 Setup Mode.... 2 Lights/Alarms.... 3 Operation.... 4 Calibration....

More information

INSTRUCTION MANUAL MST AFTERCOOLER SYSTEM MODEL

INSTRUCTION MANUAL MST AFTERCOOLER SYSTEM MODEL INSTRUCTION MANUAL MST AFTERCOOLER SYSTEM MODEL 8059601 To be used with MST Model 8050501 Ambient Air Pump 7/12/05 2 TABLE OF CONTENTS GENERAL INFORMATION... 3 WARNING...4,5 UNPACKING AND AFTERCOOLER ASSEMBLY

More information

OPERATION & MAINTENANCE INSTRUCTIONS

OPERATION & MAINTENANCE INSTRUCTIONS 1 /2 REVERSIBLE AIR DRILL MODEL NO: CAT123 PART NO: 3110879 OPERATION & MAINTENANCE INSTRUCTIONS GC1110 INTRODUCTION Thank you for purchasing this CLARKE product. Before attempting to use this product,

More information

MODEL Maverick Heavy Duty Aerosol Compressor Operator s Manual

MODEL Maverick Heavy Duty Aerosol Compressor Operator s Manual MODEL 50012 Maverick Heavy Duty Aerosol Compressor Operator s Manual This page left blank intentionally CONTENTS Page No. INSPECTION... 1 GENERAL INFORMATION... 1 SAFETY PRECAUTIONS... 2 BASIC OPERATING

More information

ULTRA-LIGHT DUTY ONBOARD AIR SYSTEM

ULTRA-LIGHT DUTY ONBOARD AIR SYSTEM ULTRA-LIGHT DUTY ONBOARD AIR SYSTEM PART NO. 10000 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using

More information

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator. LRS(H)4 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to the

More information

INTENDED USE TECHNICAL SPECIFICATIONS

INTENDED USE TECHNICAL SPECIFICATIONS 1/2IN. HEAVY-DUTY AIR IMPACT WRENCH OWNER S MANUAL WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result

More information

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL www.modsafe.com SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device.

More information

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions RAM 4021-PR Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021-PR For Your Safety... 2 Description.... 2 Setup Mode.... 2 Lights/Alarms.... 3 Operation.... 4

More information

RDK-408D2 Cold Head. Technical Manual. SHI-APD Cryogenics Inc Vultee Street Allentown, PA U.S.A. Revision A: September 2005

RDK-408D2 Cold Head. Technical Manual. SHI-APD Cryogenics Inc Vultee Street Allentown, PA U.S.A. Revision A: September 2005 RDK-408D2 Cold Head Technical Manual SHI-APD Cryogenics Inc. 1833 Vultee Street Allentown, PA 18103-4783 U.S.A. Revision A: September 2005 (Reference SHI Manual: December 18, 2003 266404A CD32ZZ-160A)

More information

SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons

SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons Air Flow Capacity 6.2 CFM at 40 PSI 5.2 CFM at 90 PSI Motor 2.5 HP Working / 4 HP Peak 120 Volt / 60 Hz / 13 A / 1-Phase Required

More information

Nitrogen Supply System

Nitrogen Supply System ATMOSCOPE Nitrogen Supply System NS500 Users Guide Copyright 2001 EDSYN, INC. ATMOSCOPE Nitrogen Supply Systems TABLE OF CONTENTS Introduction............................. 3 General Information.......................

More information

Installation and Maintenance Manual. ECO Filtration Unit with 6-way-Top-Mount-Valve. Art. Nr

Installation and Maintenance Manual. ECO Filtration Unit with 6-way-Top-Mount-Valve. Art. Nr Installation and Maintenance Manual ECO Filtration Unit with 6-way-Top-Mount-Valve Art. Nr. 300100 300101 300102 Important Details: - Using of this filtration unit for swimming pools and its guard band

More information

SAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions. IMPORTANT NOTICE

SAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions.  IMPORTANT NOTICE SAPAG IMPORTANT NOTICE Contents Important notice 1 0 Valve identification 2 1 Storage 2 2 Installation 2 3 Operation 2 4 Maintenance 3 4.1 Dismantling 3 4.2 Inspection 3 4.3 Repair 3 4.4 Assembly 4 4.5

More information