1 Oxylog VE300 Emergency & Transport Ventilation The straightforward and user-friendly Dräger Oxylog VE300 is built to face your challenges in preclinical emergency services With reliable ventilation technology, robustness and intuitive operation, it provides you with reliable and safe assistance in an emergency

2 02 Oxylog VE300 Benefits Simple, ergonomic, robust and economical: Reliable even under extreme operating conditions (-20 to +50 C) Device start in three steps, takes less than 10 seconds Device check takes less than a minute Preset parameters for fast ventilation start Replaceable and rechargeable battery for up to 9 hours of operation Low oxygen consumption thanks to DuroFlow technology* Clear user guidance with moderate training time Easily accessible documentation with Bluetooth and USB interface: patient data, system test, screen shots Wall mount permits flexible positioning Practical extras available as options: belt, stretcher mounting, accessory bag, battery charger Ergonomic carrying handle directly above the device s centre of gravity Easy to carry, quick-start ventilation Clear colour touch screen Flip-screen button rotates the display 180 Volume-controlled ventilation: VC-CMV / VC-AC, VC-SIMV Spontaneous breathing support: SPN-CPAP/PS with NIV Pressure support: PS CPR mode can be selected with a single keystroke Capnography: main-stream CO₂ measurement Logbook supports documentation *DuroFlow technology: based on the Venturi-Principle without additional base flow

3 Oxylog VE Related Products Oxylog 1000 The Oxylog has been the natural choice of emergency care ventilator for more than 25 years The Oxylog 1000 is the most compact ventilator in the Oxylog range MT MT Oxylog 2000 plus Step up your performance with Oxylog 2000 plus The Oxylog 2000 plus supports you in your daily challenge of saving peoples lives, no matter where the call takes you Invasive or non-invasive, Oxylog 2000 plus can meet this challenge by putting essential ventilation tools at your fingertips The Oxylog 2000 plus can make all the difference Dräger Oxylog 3000 plus Offering high ventilation performance with features such as AutoFlow integrated capnography and non-invasive Ventilation, the compact and robust Oxylog 3000 plus helps you transport your patients safely and provides feedback on correctness of intubation and ventilation effectiveness The Oxylog 3000 plus gives you confidence to master even the most demanding situations D

4 04 Oxylog VE300 Technical Data Device specifications Dimension (W x H x D) Basic device Basic device, with carrier system Weight Basic device, without battery Basic device, with battery Basic device, with carrier system, battery and bag Screen Technology Size External connections USB Sound pressure level (SPL) Average sound pressure level Leq(A) (Free-field measurement at 1 m distance according to ISO 3744, with typical ventilation): Sound pressure level L(A) of alarm signals (measured according to IEC ) 399 x 153 x 160 mm (157 x 68 x 63 inches) 580 x x 160 mm (228 x x 63 inches) Approx 33 kg (73 lb) Approx 36 kg (79 lb) Approx 56 kg (124 lb) TFT colour screen 43 inch 20 Only passive, ie do not connect storage media without an independent electrical power supply 45 db (A) Approx 60 to 70 db(a), depending on alarm priority Ambient conditions Operating conditions Temperature (device) Temperature (power supply) Ambient pressure (device) Height above sea level Ambient pressure (power supply) Relative humidity -20 C to +50 C (-4 to +122 F) 0 C to +50 C (+32 F to +122 F) 620 to 1,100 hpa (899 to 1595 psi) Automatic ambient pressure compensation within this pressure range Up to 4,000 m (13,123 feet) 700 to 1,200 hpa (1015 to 1595 psi) 5 to 95% (without condensation) Settings Ventilation modes Optional Respiratory rate RR VC-CMV, VC-AC, SPN-CPAP VC-SIMV/PS, SPN-CPAP/PS 2 to 50 /min (VC-SIMV) 5 to 50 /min (VC-AC, VC-AC) Maximum airway pressure Pmax 20 to 60 mbar (20 to 60 cmh 2 O) Ratio of inspiration time to expiration time I:E 1:4 to 4:1 Inspiration time Ti Tidal volume VT O 2 concentration 03 to 10 s 01 to 20 L, BTPS Measured values based on patient's lung conditions, body temperature 37 C (986 F), ambient pressure, water vapour-saturated gas 100% O 2 and O 2 /air mixture Actual value depends on inspiratory flow and mean airway pressure Positive end-expiratory pressure PEEP 0 to 20 mbar (0 to 20 cmh 2 O) Trigger sensitivity (flow trigger) Trigger sensitivity (pressure trigger) 1 to 15 L/min 1 to 15 steps

5 Oxylog VE Technical Data Pressure support ΔPsupp 0 to 35 mbar (0 to 35 cmh 2 O) (relative to PEEP) Pressure rise time for pressure support slow (1 s), standard (04 s), fast Regions of alarm limits MVe high MVe low RR high etco 2 high etco 2 low 2 to 60 L/min 05 to 40 L/min 10 to 99 /min 5 to 99 mmhg / 05 to 132 kpa / 05 to 132 vol% 0 to 94 mmhg / 0 to 127 kpa / 0 to 127 vol% Performance characteristics Control principle Maximum inspiratory flow 100 L/min 1 Device compliance Time-controlled, constant volume, pressure monitored with 15 m breathing tube < 15 ml/mbar (15 cmh 2 O) with 30 m breathing tube < 2 ml/mbar (2 cmh 2 O) Inspiratory and expiratory resistance of the device with breathing tube system, with Plus option Inspiratory and expiratory resistance of the device with breathing tube system, without Plus option Emergency air valve Safety valve < 6 mbar (6 cmh 2 O) at 60 L/min < 4 mbar (4 cmh 2 O) at 30 L/min < 2 mbar (2 cmh 2 O) at 5 L/min < 6 mbar (6 cmh 2 O) at 60 L/min < 4 mbar (4 cmh 2 O) at 30 L/min < 2 mbar (2 cmh 2 O) at 5 L/min Opens breathing system if there is insufficient gas and enables spontaneous breathing with room air Opens breathing system if device fails at about 80 mbar (80 cmh 2 O) 1 At supply pressure > 350 kpa (5076 psi) At a supply pressure < 350 kpa (5076 psi), the maximum inspiratory flow is reduced to 80 L/min, at a supply pressure < 280 kpa (4061 psi) to 39 L/min Values displayed Airway pressure measurement 0 to 100 mbar, BTPS Resolution 1 mbar (1 cmh 2 O) Accuracy ±(2 mbar (2 cmh 2 O) +2% of measured value) Flow Measurement Minute volume MVe Resolution Accuracy Tidal volume VTe Resolution Accuracy CO 2 measurement (option) Measurement basis Resolution 0 to 100 L/min, BTPS 01 L/min ± 20% of measured value or ± 04 L/min, the larger value applies 0 to 5,000 ml, BTPS 1 ml ± 20% of measured value or ± 20 ml, the larger value applies (adults-breathing tube) Main-stream method 0 to 100 mmhg / 0 to 132 vol% / 0 to 133 kpa 1 mmhg / 01 vol% / 01 kpa

6 06 Oxylog VE300 Technical Data Respiratory rate measurement Resolution Accuracy 0 to 99 /min 1 /min ±1 /min Graph Airway pressure Paw (t) 0 to 90 mbar (0 to 90 cmh 2 O) CO 2 0 to +100 mmhg / 0 to +15 vol% / 0 to +15 kpa Monitoring Expiratory minute volume MVe (option) Alarm, upper alarm limit If the upper alarm limit has been exceeded 2 to 60 L/min Alarm, lower alarm limit Apnoea Alarm Respiratory rate RR Alarm, upper alarm limit End expiratory CO 2 concentration - etco 2 (option) Alarm, upper alarm limit Alarm, lower alarm limit Leakage Alarm Disconnection Alarm Data communication (option) Exported data If the value has fallen below the lower alarm limit 05 to 40 L/min 40 seconds after start of ventilation If no respiratory phase change for > 15 seconds is detected If the upper alarm limit has been exceeded 10 to 99 /min 30 seconds after start of ventilation If the upper alarm limit has been exceeded 5 to 99 mmhg / 05 to 132 kpa / 05 to 132 vol% 30 seconds after connection and calibration If the value has fallen below the lower alarm limit 0 to 94 mmhg / 0 to 127 kpa / 0 to 127 vol% 30 seconds after start of ventilation, connection and calibration Only for Plus option in VC modes and with NIV switched off in CPAP: If VTe < 45% of VTi 30 seconds after start of ventilation If disconnection of the breathing tube system is detected 30 seconds after start of ventilation Measurements Curves Alarm messages Alarm settings User settings System test information Screenshots

7 Oxylog VE Technical Data Operating characteristics Power supply Input Voltage Operating time Power consumption Battery type Charging time 19 V + 5/-3 VDC Power supplies (power supply and DC voltage converter) are specified as parts of the Oxylog VE300 With new and fully charged battery, without external power supply: 8 hours with typical ventilation (VC-CMV, RR = 12/min, VT = 500 ml, PEEP = 5 mbar (5 cmh 2 O), I:E = 1:2) 9 hours (without CO 2 sensor and low screen brightness) While charging: max 20 A at 19 VDC With typical ventilation: max 08 A at 19 VDC Lithium-ion battery Approx 5 hours The indicated charging time refers to full charging of the battery after discharge Power supply unit Protection class (according to IEC ) Protection class Input Class II IP to 240 V~ / 50/60 Hz / 10 A Output 19 V / 447 A (0 to +40 C (32 to +104 F)) / 357 A (+40 to +50 C (+104 to 122 F)) Fuses F1 and F2 T 25 A / 250 V~ To disconnect the ventilator from the mains, pull the power cable out of the mains socket The power supply unit is designed for indoor use (eg in hospitals or fire stations) Gas supply Oxygen supply pressure Gas characteristics Connection to the oxygen supply: From a central gas supply system or an oxygen cylinder 270 to 690 kpa (3916 to psi) Medical oxygen, 93% oxygen NIST (Non-Interchangeable Screw-Threaded) according to EN 739 / ISO 5359 or DISS (Diameter Index Safety Systems) according to CGA V or NF (Norme française) S Specific quick connection

8 08 Oxylog VE300 Notes Not all products, features, or services are for sale in all countries Mentioned Trademarks are only registered in certain countries and not necessarily in the country in which this material is released Go to wwwdraegercom/trademarks to find the current status HQ PP Subject to modifications 2017 Drägerwerk AG & Co KGaA CORPORATE HEADQUARTERS Drägerwerk AG & Co KGaA Moislinger Allee Lübeck, Germany wwwdraegercom Manufacturer: Drägerwerk AG & Co KGaA Moislinger Allee Lübeck, Germany REGION DACH Dräger Safety AG & Co KGaA Revalstraße Lübeck, Germany Tel Fax REGION EUROPE Dräger Safety AG & Co KGaA Revalstraße Lübeck, Germany Tel Fax REGION MIDDLE EAST, AFRICA Dräger Safety AG & Co KGaA Branch Office PO Box Dubai, United Arab Emirates Tel Fax REGION ASIA PACIFIC Draeger Singapore Pte Ltd 25 International Business Park #04-20/21 German Centre Singapore Tel Fax REGION CENTRAL AND SOUTH AMERICA Dräger Panama S de RL Complejo Business Park, V tower, 10th floor Panama City Tel Fax Locate your Regional Sales Representative at: wwwdraegercom/contact

Oxylog 2000 plus Emergency & Transport Ventilation

Oxylog 2000 plus Emergency & Transport Ventilation Oxylog 2000 plus Emergency & Transport Ventilation Step up your performance with Oxylog 2000 plus. The Oxylog 2000 plus supports you in your daily challenge of saving peoples lives, no matter where the

More information

Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring

Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring The Dräger Savina 300 Select (in this configuration) combines the independence and power of a turbine-driven ventilation system with

More information

Dräger Evita Infinity V500 ventilator ICU Ventilation and Respiratory Monitoring

Dräger Evita Infinity V500 ventilator ICU Ventilation and Respiratory Monitoring Dräger Evita Infinity V500 ventilator ICU Ventilation and Respiratory Monitoring Combine fully-featured, high-performance ventilation with Infinity Acute Care System integration to meet the challenges

More information

D Quality and Precision you can Trust in Oxygen Administration CONVENTIONAL FLOWMETER DIGITAL FLOWMETER COMPACT FLOWMETER

D Quality and Precision you can Trust in Oxygen Administration CONVENTIONAL FLOWMETER DIGITAL FLOWMETER COMPACT FLOWMETER D-10023-2009 Quality and Precision you can Trust in Oxygen Administration CONVENTIONAL FLOWMETER DIGITAL FLOWMETER COMPACT FLOWMETER 02 MT-3287-2003 Administration of oxygen The use of oxygen therapy in

More information

Evita V300 ICU Ventilation and Respiratory Monitoring

Evita V300 ICU Ventilation and Respiratory Monitoring Evita V300 ICU Ventilation and Respiratory Monitoring The Evita V300 is a scalable and versatile device which offers high ventilation quality To meet and master the changing conditions and challenges of

More information

The secret of harmonious breathing BABYLOG 8000 PLUS

The secret of harmonious breathing BABYLOG 8000 PLUS MT-1166-2005 The secret of harmonious breathing BABYLOG 8000 PLUS 02 The product of expertise and experience More than 30 years of experience in neonatal ventilation and a century of expertise in breathing

More information

Dräger OCEANUS 140 Mobile Compressor

Dräger OCEANUS 140 Mobile Compressor Dräger OCEANUS 140 Mobile Compressor The Dräger OCEANUS 140 mobile compressor is designed for operations at sea. Tank Filling tube with filling valve Exhaust Safety valve Air filter Filter system P21 Petrol

More information

The secret of harmonious breathing BABYLOG 8000 PLUS

The secret of harmonious breathing BABYLOG 8000 PLUS D-19679-2015 The secret of harmonious breathing BABYLOG 8000 PLUS 02 The product of expertise and experience More than 40 years of experience in neonatal ventilation and a century of expertise in breathing

More information

D Made to meet your needs DRÄGER SAVINA 300

D Made to meet your needs DRÄGER SAVINA 300 D-46452-2012 Made to meet your needs DRÄGER SAVINA 300 2 DRÄGER SAVINA 300 How can your ventilator help you manage your daily challenges? In many parts of the world, geographical and infrastructure challenges

More information

Dräger-Tube pump accuro Dräger Tube Pump

Dräger-Tube pump accuro Dräger Tube Pump Dräger-Tube pump accuro Dräger Tube Pump Fast measurement with one hand: The Dräger-Tube pump accuro allows you to use the established Dräger-Tubes to take measurements under extreme conditions. The easy-to-use

More information

Dräger Tactical Harness Versatile carrying harness for LAR rebreathers.

Dräger Tactical Harness Versatile carrying harness for LAR rebreathers. Dräger Tactical Harness 1000 Versatile carrying harness for LAR rebreathers. D-57980-2012 02 Dräger Tactical Harness 1000 Benefits Instantly ready for the mission Via quick connections, the apparatus is

More information

Dräger Short-term Tubes Dräger-Tubes

Dräger Short-term Tubes Dräger-Tubes Dräger Short-term Tubes Dräger-Tubes Tried and tested a million times: Worldwide, the Dräger Short-term Tubes have proven to be a very cost-effective and reliable method for the measurement of gases. Decreasing

More information

Dräger Secor 7000 Diving Equipment and Systems

Dräger Secor 7000 Diving Equipment and Systems Dräger Secor 7000 Diving Equipment and Systems The diving regulator Dräger Secor 7000 was developed for the professional diver The medium pressure hose can be attached to either side of the 2nd stage to

More information

Dräger Compressed Air Breathing Cylinders Accessories for Breathing Apparatus

Dräger Compressed Air Breathing Cylinders Accessories for Breathing Apparatus Dräger Compressed Air Breathing Cylinders Accessories for Breathing Apparatus Designed using leading technology and advanced materials, Dräger s range of Composite Cylinders can be used in any application

More information

Aquacom Diving Equipment

Aquacom Diving Equipment Aquacom Diving Equipment Tough, powerful and a must for professional search and rescue teams, the Aquacom system ensures clear communication between underwater divers and surface control. D-27802-2009

More information

Filtering Escape Device

Filtering Escape Device Filtering Escape Device The is a half mask escape device equipped with a multi-gas AEK filter. Packed in a robust and ergonomic case the unit is compact and easy to carry. Approved to the only recognized

More information

Dräger Bodyguard 7000 Warning Device

Dräger Bodyguard 7000 Warning Device Dräger Bodyguard 7000 Warning Device The Dräger Bodyguard 7000 is an electronic monitoring unit which provides continuous monitoring of personal information and operational status of the Dräger PSS 7000

More information

Dräger PAS AirPack 1 Compressed Air Breathing Apparatus

Dräger PAS AirPack 1 Compressed Air Breathing Apparatus Dräger PAS AirPack 1 Compressed Air Breathing Apparatus Designed using leading technology and materials, Dräger s range of heavy-duty airline apparatus is ideal for use where an extended duration of breathing

More information

OxyLine The customised pressure reducer

OxyLine The customised pressure reducer OxyLine The customised pressure reducer A mobile supply should be built exactly to your specifications. That is why Dräger developed the OxyLine series of pressure reducers. OxyLine can be used independently

More information

Dräger CPS 6900 Gas-Tight Suit

Dräger CPS 6900 Gas-Tight Suit Dräger CPS 6900 Gas-Tight Suit If you are looking for protection against cryogenic hazardous substances and low concentrations of acids and alkalis then the Dräger CPS 6900 chemical protective suit is

More information

Dräger PAS AirPack 2 Compressed Air Breathing Apparatus

Dräger PAS AirPack 2 Compressed Air Breathing Apparatus Dräger PAS AirPack 2 Compressed Air Breathing Apparatus Designed using leading technology and materials, Dräger s range of heavy-duty airline apparatus is ideal for use where an extended duration of breathing

More information

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV VENTIlogic LS VENTIlogic plus 100 % Mobility and Reliability in IV and NIV VENTIlogic VENTIlog LS Your Requirements for Reliability and Mobility are Our Benchmark. VENTIlogic LS and VENTIlogic plus are

More information

INTENSIVE CARE VENTILATORS

INTENSIVE CARE VENTILATORS INTENSIVE CARE VENTILATORS iternis ADV INTENSIVE CARE VENTILATION FOR ALL PATIENT CATEGORIES Design Features HEYER iternis ADV s 12-inch touch-screen display combines comprehensive, easy-to-follow user

More information

Fabius Tiro TM. Designed for your environment. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Fabius Tiro TM. Designed for your environment. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care Fabius Tiro TM Designed for your environment Emergency Care Perioperative Care Critical Care Perinatal Care Home Care Traditional hospital ORs have their needs... With more surgical procedures being performed

More information

Dräger TSW Elephant Diving Equipment

Dräger TSW Elephant Diving Equipment Dräger TSW Elephant Diving Equipment The world s first universal diving harness integrating the rebreather provides you with all four diving components needed for water depths up to 24 meters: basic vest,

More information

Narkomed MRI-2. A perfect fit for the MRI environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Narkomed MRI-2. A perfect fit for the MRI environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care Narkomed MRI-2 A perfect fit for the MRI environment Emergency Care Perioperative Care Critical Care Perinatal Care Home Care Because you care The complete anesthesia solution for the MRI environment A

More information

Fabius Tiro TM. Designed for your environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Fabius Tiro TM. Designed for your environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care Fabius Tiro TM Designed for your environment Emergency Care Perioperative Care Critical Care Perinatal Care Home Care Because you care Traditional hospital ORs have their needs... With more surgical procedures

More information

Fabius GS premium. The evolution of value. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Fabius GS premium. The evolution of value. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care Fabius GS premium The evolution of value Emergency Care Perioperative Care Critical Care Perinatal Care Home Care Because you care An ever-changing environment is your business keeping pace with its demands

More information

The anaesthesia workstation focused on you

The anaesthesia workstation focused on you by The anaesthesia workstation focused on you With the most advanced anaesthesia Accuracy and performance Equipped with the most advanced ventilation modes. Electronic rotameters with precise mass-flow

More information

SLE5000 Infant Ventilator with HFO

SLE5000 Infant Ventilator with HFO SLE5000 Infant Ventilator with HFO When the smallest thing matters SLE5000 - The Total Solution for Infant Ventilation Shown on optional roll stand. Ventilator may be mounted either way round on stand.

More information

Enrich life. Astral 100 and 150: Time to rethink respiratory care. ResMed.com/Astral

Enrich life. Astral 100 and 150: Time to rethink respiratory care. ResMed.com/Astral Enrich life Astral 100 and 150: Time to rethink respiratory care ResMed.com/Astral Versatile life support ventilation ResMed s Astral 100 and Astral 150 life support ventilators offer excellence in invasive

More information

Technology Insights Paediatric Ventilation

Technology Insights Paediatric Ventilation 01 Technology Insights Paediatric Ventilation Ventilation of paediatric patients during general anaesthesia poses major requirements to anaesthesia workstations. Dräger works closely with clinicians and

More information

Technology Insights for protective ventilation and spontaneous breathing in the OR

Technology Insights for protective ventilation and spontaneous breathing in the OR CHAPTER SUBSECTION 01 Technology Insights for protective ventilation and spontaneous breathing in the OR Protective ventilation in the OR poses major requirements to anaesthesia Workstations. Dräger works

More information

Monnal T60. Touch and Breathe.

Monnal T60. Touch and Breathe. Monnal T60 Touch and Breathe www.airliquidemedicalsystems.com Close to the emergency Monnal T60 has been designed for mobile medical intervention in all intensive care environments, both inside and outside

More information

Dräger PSS 5000 Compressed Air Breathing Apparatus

Dräger PSS 5000 Compressed Air Breathing Apparatus Dräger PSS 5000 Compressed Air Breathing Apparatus The Dräger PSS 5000 SCBA is a high-performance breathing apparatus for the professional firefighter. Combining advanced ergonomics with a wide range of

More information

DATA SHEET. VENTILATION SERVO-i INFANT HIGHLIGHTS

DATA SHEET. VENTILATION SERVO-i INFANT HIGHLIGHTS DATA SHEET VENTILATION HIGHLIGHTS For neonatal to pediatric patients Intuitive user interface Designed for cost-efficiency Flexible placement Modular - interchangeable plug-in units Enables Heliox delivery

More information

CPAP Devices - Masks - Accessories for respiratory assistance in CPAP

CPAP Devices - Masks - Accessories for respiratory assistance in CPAP Devices - Masks - Accessories for respiratory assistance in HAROL is one of the Italian companies leader in developing and selling systems, determining the most appropriate solutions for all your needs.

More information

SLE5000 Neonatal Ventilator with High Frequency Oscillation

SLE5000 Neonatal Ventilator with High Frequency Oscillation SLE5000 Neonatal Ventilator with High Frequency Oscillation The SLE5000 is superb: the best High Frequency Ventilator I ve used When the smallest thing matters SLE5000 - The Total Solution for Infant Ventilation

More information

The Crossvent 2i+ 2. Ventilator Concept (brief theory of operation and features)

The Crossvent 2i+ 2. Ventilator Concept (brief theory of operation and features) The Crossvent 2i+ 1. How is this ventilator classified 2. Ventilator Concept (brief theory of operation and features) -Your Two Choices with this Ventilator 3. An overview of the device (an in-service)

More information

PERSEO EVOLUTION. workstation for gaseous anaesthesia. for adults, children and newborns. Code: OM 403 / 3 gas module 3 rotameter

PERSEO EVOLUTION. workstation for gaseous anaesthesia. for adults, children and newborns. Code: OM 403 / 3 gas module 3 rotameter ESSE 3 Via Garibaldi 30 14022Castelnuovo D.B. (AT) tel +39 011 99 27 706 fax +39 011 99 27 506 e-mail esse3@chierinet.it web : www.4ci.com PERSEO EVOLUTION workstation for gaseous anaesthesia for adults,

More information

MT Redefining Anaesthesia. Dräger Zeus

MT Redefining Anaesthesia. Dräger Zeus MT-5570-2008 Redefining Anaesthesia Dräger Zeus Infinity Empowered 02 Dräger Zeus InfinITy empowered The potential to do more D-9255-2009 Dräger Zeus InfinITy empowered 03 Introducing the Dräger Zeus Infinity

More information

Dräger Mine Refuge Chamber MRC 5000 Innovative, portable life support system

Dräger Mine Refuge Chamber MRC 5000 Innovative, portable life support system Dräger Mine Refuge Chamber MRC 5000 Innovative, portable life support system Looking for ways to increase the safety of your work environment? An underground emergency chamber is a key part of any mine

More information

Neonatal Ventilators. Touch-screen Neonatal Ventilator with High Frequency Oscillation SLE5000

Neonatal Ventilators. Touch-screen Neonatal Ventilator with High Frequency Oscillation SLE5000 Neonatal Ventilators Touch-screen Neonatal Ventilator with High Frequency Oscillation SLE5000 SLE5000: Designed for Neonates Neonatal ventilation poses real challenges to neonatologists and caregivers.

More information

State-of-the-art anesthesia technology

State-of-the-art anesthesia technology State-of-the-art anesthesia technology anesthesia system Get closer to the MRI scanner Superb certified performance in close proximity to strong magnetic fields. Our innovative machine provides benefits

More information

Additel 761 Automated Pressure Calibrators

Additel 761 Automated Pressure Calibrators Automated Calibrators UPDATED Fully automated pressure calibrator with built-in pressure generator / controller to as high as 600 psi (40 bar) or as low as 0.01 Pa (0.00004 inh 2 O) accuracy Dual pressure

More information

HAMILTON-MR1. Technical specifications HAMILTON-MR1

HAMILTON-MR1. Technical specifications HAMILTON-MR1 HAMILTONMR1 HAMILTONMR1 Technical specifications The HAMILTONMR1 guarantees uncompromised continuous ventilation care from the ICU to the MRI scanner and back. Its reliability and high performance, with

More information

Dräger X-act 5000 Automatic Dräger Tube Pump

Dräger X-act 5000 Automatic Dräger Tube Pump Dräger X-act 5000 Automatic Dräger Tube Pump The automatic tube pump Dräger X-act 5000 is the first all-in-one solution designed for measurements with Dräger short-term tubes and for sampling tubes and

More information

Additel 761 Automated Pressure Calibrators Selection Guide

Additel 761 Automated Pressure Calibrators Selection Guide / Process Calibration Equipment Automated Calibrators Selection Guide Model Features Range Module 1 761-LLP 761-D 761-L 761-LA 761-M 761-MA 761-H 761-HA 761-BP -2.5 to 2.5 mbar (-1 to 1 inh 2 O) -0.95

More information

This multi-functional device allows the determination of up to six quality parameters with only one measurement:

This multi-functional device allows the determination of up to six quality parameters with only one measurement: Devices for determination of the gas quality For verification of several parameters in one operation 3-038-R... Multi-Analyser without return system 3-038R-R... Multi-Analyser with return system This multi-functional

More information

fabian HFO Our 4-in-1 device

fabian HFO Our 4-in-1 device fabian HFO Our 4-in-1 device Ventilation Beyond Limits When It Comes to Life, There Is No Compromise Distributing worldwide ACUTRONIC is a privately held company that develops, manufactures, and distributes

More information

Mechanical Ventilation

Mechanical Ventilation Mechanical Ventilation Understanding Modes Rob Chatburn, RRT-NPS, FAARC Research Manager Respiratory Therapy Cleveland Clinic Associate Professor Case Western Reserve University 1 Overview Characteristics

More information

DATA SHEET. ANESTHESIA SYSTEM FLOW-i

DATA SHEET. ANESTHESIA SYSTEM FLOW-i DATA SHEET ANESTHESIA SYSTEM FLW-i 2 FLW-i Critical Care FLW-i General System model C20 C30 C40 Base system weight (depending on configuration) Dimensions of base plate Approx. 138 kg/ 304 lbs 692 x 985

More information

Innovating with you Shaping exceptional care

Innovating with you Shaping exceptional care S/5 Avance Innovating with you Shaping exceptional care Shown with S/5 Anesthesia Monitor Features Complete patient monitoring capabilities: respiratory gas, hemodynamic and adequacy of anesthesia Our

More information

Tailor-made breathing

Tailor-made breathing Tailor-made breathing YN170612 - V.2.0 - January 2017 - Art direction : Communication agency Marquetis www.device.airliquidehealthcare.com AL-Monnal-T75-A4-GB.indd 1 15/02/2017 17:23 Meeting your requirements

More information

D At your side in the emergency management

D At your side in the emergency management D-32108-2011 At your side in the emergency management 2 We invest in training and equipment. It pays off when something goes wrong. D-32083-2011 D-32110-2011 D-32111-2011 Get out of danger fast When something

More information

UNDERSTANDING NEONATAL WAVEFORM GRAPHICS. Brandon Kuehne, MBA, RRT-NPS, RPFT Director- Neonatal Respiratory Services

UNDERSTANDING NEONATAL WAVEFORM GRAPHICS. Brandon Kuehne, MBA, RRT-NPS, RPFT Director- Neonatal Respiratory Services UNDERSTANDING NEONATAL WAVEFORM GRAPHICS Brandon Kuehne, MBA, RRT-NPS, RPFT Director- Neonatal Respiratory Services Disclosures Purpose: To enhance bedside staff s knowledge of ventilation and oxygenation

More information

cooled, Heated ATH 2800 MT, DN 250 ISO-F, External drive electronics, Water cooled, Heated

cooled, Heated ATH 2800 MT, DN 250 ISO-F, External drive electronics, Water cooled, Heated ATH 2800 MT, DN 250 ISO-F, External drive electronics, Water cooled, Heated ATH 2800 MT, DN 250 ISO-F, External drive electronics, Water cooled, Heated ATH 2800 MT, DN 250 ISO-F, External drive electronics,

More information

HAMILTON-T1. Technical specifications HAMILTON-T1

HAMILTON-T1. Technical specifications HAMILTON-T1 HAMILTNT1 HAMILTNT1 Technical specifications The HAMILTNT1 is the first highend transport ventilator especially developed to meet the needs of ventilated ICU patients in all transport situations. The HAMILTNT1

More information

Alcotest Breath Alcohol Screening Device. Operator Instructions for Use. ST _sw.eps

Alcotest Breath Alcohol Screening Device. Operator Instructions for Use. ST _sw.eps D Alcotest 6510 Breath Alcohol Screening Device Operator Instructions for Use ST-207-2004_sw.eps Contents Contents................................................. 2 For your safety............................................

More information

MEDUMAT Transport. Emergency ventilator. Description and Instructions for Use for Devices from Firmware Version 2.17

MEDUMAT Transport. Emergency ventilator. Description and Instructions for Use for Devices from Firmware Version 2.17 MEDUMAT Transport Emergency ventilator Description and Instructions for Use for Devices from Firmware Version 2.17 Contents 1. Overview..................... 4 2. Description................... 17 2.1 Intended

More information

Draeger Fabius GS Pre-Use Check

Draeger Fabius GS Pre-Use Check Draeger Fabius GS Pre-Use Check James H Philip MEE, MD, CCE 2011 James H Philip All rights reserved Remember to enter Machine # Fabius GS front view Fabius GS pre-use checkout procedure Fabius GS pre-use

More information

FLIGHT 60 Ventilator T-edition

FLIGHT 60 Ventilator T-edition FLIGHT MEDICAL INNOVATIONS LTD. FLIGHT 60 Ventilator T-edition Operator's Manual LIT-0106 Rev. A00 OPERATING MANUAL-FLIGHT60 TURBINE for USA Legal Notice Legal Notice Disclaimer FLIGHT MEDICAL INNOVATIONS

More information

Transmitter CS 21 Operation Manual

Transmitter CS 21 Operation Manual Transmitter CS 21 Operation Manual Content Page For your Safety 3 General Description 3 Detection Principle 4 Operational Notes 4 Design 4 Mounting Position of CS21 5 Mounting 6 Installation of Electrical

More information

Mechanical Ventilation. Flow-Triggering. Flow-Triggering. Advanced Concepts. Advanced Concepts in Mechanical Ventilation

Mechanical Ventilation. Flow-Triggering. Flow-Triggering. Advanced Concepts. Advanced Concepts in Mechanical Ventilation Mechanical Ventilation Advanced Concepts in Mechanical Ventilation Flow-Triggering Trigger = the variable that causes the vent to begin the inspiratory phase Common triggers 1-2- 3- Effort required to

More information

Babylog 8000 plus. Intensive Care Ventilator for Neonates Software 5.n Instructions for Use

Babylog 8000 plus. Intensive Care Ventilator for Neonates Software 5.n Instructions for Use Babylog 8000 plus WARNING: For a full understanding of the performance characteristics of this medical device, the user should carefully read these Instructions for Use before use of the medical device.

More information

Dräger CPS 7900 Gas-Tight Suit

Dräger CPS 7900 Gas-Tight Suit Dräger CPS 7900 Gas-Tight Suit Tailor-made for use under extreme conditions: The gas-tight Dräger CPS 7900 provides excellent protection against industrial chemicals, biological agents, and other toxic

More information

Gas exchange measurement in module M- COVX

Gas exchange measurement in module M- COVX Gas exchange measurement in module M- COVX This document explains how the gas exchange measurement in the gas module M-COVX works. 1. Basic equations To obtain the oxygen consumption VO2 of a patient,

More information

ila ACTIVVE SYSTEM PLATFORM

ila ACTIVVE SYSTEM PLATFORM ila ACTIVVE SYSTEM PLATFORM Custom-tailored Extrapulmonary Lung Support ila activve : Custom-Tailored Extrapulmonary gas exchange Extrapulmonary blood flow: as high as necessary as low as possible. The

More information

Dräger X-plore 6300 Full Face Mask

Dräger X-plore 6300 Full Face Mask Dräger X-plore 6300 Full Face Mask ST-7497-2005 The Dräger X-plore 6300 is an efficient, low-cost full face breathing mask intended for price-conscious users not wishing to compromise comfort or quality.

More information

pneuton Transport Ventilator

pneuton Transport Ventilator The pneuton Ventilator is under US patent protection. (Patent # 6,591,835) pneuton is a Registered Trademark of the Airon Corporation Copyright 2012 by Airon Corporation pneuton Transport Ventilator mini

More information

PACE Modular Pressure Controller

PACE Modular Pressure Controller GE Measurement & Control Solutions PACE Modular Pressure Controller A new generation of high precision Druck pressure controller, designed for test bench, bench top & rack mount calibration & automated

More information

Principles of mechanical ventilation. Anton van Kaam, MD, PhD Emma Children s Hospital AMC Amsterdam, The Netherlands

Principles of mechanical ventilation. Anton van Kaam, MD, PhD Emma Children s Hospital AMC Amsterdam, The Netherlands Principles of mechanical ventilation Anton van Kaam, MD, PhD Emma Children s Hospital AMC Amsterdam, The Netherlands Disclosure Research grant Chiesi Pharmaceuticals Research grant CareFusion GA: 27 weeks,

More information

MEDAP-FLOWMETERS FOR OXYGEN AND COMPRESSED AIR

MEDAP-FLOWMETERS FOR OXYGEN AND COMPRESSED AIR MEDAP-FLOWMETERS FOR OXYGEN AND COMPRESSED AIR This document is intended to provide information to an international audience outside of the US. The Gold Standard Surgical Workplaces Flowmeter 3 Pressure

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Bypass MFC with capillary technology for nominal flow rates from 5 ml N /min to 15 l N /min Applicable for aggressive gases Compact design and digital communication

More information

HIGH FREQUENCY JET VENTILATION (HFJV): EQUIPMENT PREPRATION

HIGH FREQUENCY JET VENTILATION (HFJV): EQUIPMENT PREPRATION POLICY The physician orders High Frequency Jet Ventilation (HFJV). The Respiratory Therapist in discussion with the physician will determine blood gas targets and ventilation settings for the treatment

More information

MEDIANA HEARTON AED A15. Mediana Automated External Defibrillator A15

MEDIANA HEARTON AED A15. Mediana Automated External Defibrillator A15 AED A5 Mediana Automated External Defibrillator A5 AED A5 COVER Protected icon sheet, shock button, adult/paediatric mode switch. 7 BATTERY Disposable LiMnO2 Non-Rechargeable. 2yrs shelf life, 5yrs standby

More information

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing Ø

More information

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor.  Type: ETd 04. class 0.05 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 100 mbar up to 0... 400 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing

More information

Servo Ventilator 300/300A

Servo Ventilator 300/300A Servo Ventilator 300/300A Service Manual Adult Pediatric Neonate 5 5 9 9. 3 0. 35 6 5. 0 59 66 5. SIEMENS E38 E380E 06 0 03 0 Important Servo Ventilator 300/300A Important General Unless stated otherwise,

More information

Pressure Controlled Modes of Mechanical Ventilation

Pressure Controlled Modes of Mechanical Ventilation Pressure Controlled Modes of Mechanical Ventilation Christopher Junker Department of Anesthesiology & Critical Care Medicine George Washington University Saturday, August 20, 2011 Assist Control Hypoxemic

More information

GasSense NDIR User Manual

GasSense NDIR User Manual INDEX INDEX... 1 1. OVERVIEW... 2 2. TECHNICAL DATA... 3 3. SPECIFICATIONS... 4 4. PRODUCT DESCRIPTION... 5 4.1 Mechanical details... 5 4.2 Piping... 7 4.3 Connections... 7 5. INSTALLATION... 10 6. CALIBRATION

More information

Recommendations on Checking Anaesthesia Delivery Systems

Recommendations on Checking Anaesthesia Delivery Systems Page 1 of 11 Recommendations on Checking Anaesthesia Delivery Version Effective Date 1 Oct 1992 (reviewed Feb 07, Feb 02) 2 2004 3 Nov 2011 4 Dec 2016 Document No. HKCA T1 v4 Prepared by College Guidelines

More information

We measure it. For gas and water installers. testo hpa. bar

We measure it. For gas and water installers. testo hpa. bar Pressure measuring instruments For gas and water installers testo 312-2 hpa testo 312-3 testo 312-4 bar C testo 312-2 / testo 312-3 Pressure meters for gas and water fitters testo 312-2 testo 312-2, fine

More information

Autocalibration Systems for In Situ Oxygen Analyzers

Autocalibration Systems for In Situ Oxygen Analyzers Product Data Sheet PDS 106-340AC.A01 February, 2006 SPS 4001B, IMPS 4000 and MPS 3000 Autocalibration Systems for In Situ Oxygen Analyzers Cost-effective autocalibration systems for installations ranging

More information

Oxygen Delivery Systems:

Oxygen Delivery Systems: Oxygen Delivery Systems: Oxygen Flow Meters with Heyer (SANS 1409) Connection: Stock Image X0038 O2 Flow Meter Single with Heyer connection, ball and tube type (0-15 Litre) (Brass Base) X0039 O2 Flow Meter

More information

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc. The HumiSys RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The new HumiSys with single or dual RH probes capabilities is

More information

Additel 780 Series Pressure Controller

Additel 780 Series Pressure Controller Additel 780 Series Pressure Controller Pressure / Process Calibration Equipment Pressure ranges from vacuum to 3,000 psi (200 bar) Removable interchangeable intelligent sensors Precision accuracy of 0.005%

More information