MODEL 100 NITROGEN INFLATION CART

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "MODEL 100 NITROGEN INFLATION CART"

Transcription

1 MODEL 100 NITROGEN INFLATION CART Installation & Operation Information Branick Industries, Inc Main Avenue P.O. Box 1937 Fargo, North Dakota REV P/N:

2 TABLE OF CONTENTS SAFETY INSTRUCTIONS 1 DEFINITIONS 1 SPECIFICATIONS 2 INSTALLATION INSTRUCTIONS 2 OPERATING INSTRUCTIONS 3 TROUBLESHOOTING 5 OWNER S RECORDS 6 WARRANTY 7 SAFETY INSTRUCTIONS NEVER allow unauthorized personnel to operate this product. NEVER use this product for anything other than its intended use. THOROUGHLY train new employees in the proper use and care of this product. PROHIBIT unauthorized personnel from being in shop area while this product is in use. DEFINITIONS CAUTION: Indicates a potentially hazardous situation, which if not avoided, may result in damage to property or minor personal injury. HAZARD: A source of potential injury to a person. MAINTENANCE: Those actions that preserve the correct and proper conditions under which the machine shall be used. This may include adjustment, replacement of wear items, lubrication and cleaning, but not modifications or repair of damage. MAY: This word is understood to be permissive. MUST: This word is understood to be mandatory. OPERATION: The correct and proper use of the machine as described in this manual. SAFETY ALERT SYMBOL: A symbol that indicates a potential personal safety hazard. It is composed of an equilateral triangle surrounding an exclamation point. SHALL: This word is understood to be mandatory. SHOULD: This word is understood to be advisory. WARNING: Indicates a potentially hazardous situation, which if not avoided, may result in death or serious personal injury. 1

3 CAUTION Before using this product, read and fully understand the operating instructions and all decals on the product. This is necessary to prevent injury to the operator and damage to the product. Do not attempt to use this product for anything other than its intended purpose. Use of this product should be in a suitably ventilated shop. Do not use this product if it is visibly worn, distorted or damaged. SPECIFICATIONS Operating Temperature 40 to 140 F (4 to 60 C) Min/Max Compressed Air Supply 100 to 150 psi (6.9 to 10.3 bar) Digital Inflator Accuracy +/- 0.3 psi (0.02 bar) Display Increments 1 psi (0.1 bar) Inflation Ports 1 to 6 (4 hoses supplied) Dimensional data 16 x 22 x 50 in (40 x 56 x 127 cm) Weight: 85 lbs (39 kgs) INTENDED USE The Nitrogen Tire Inflation Cart is a pneumatic device designed for the purpose of inflating vehicle tires. INSTALLATION INSTRUCTIONS 1. Unpack and remove unit from shipping carton and pallet. 2. Inspect the unit for any visible damage. 3. Make sure when using this unit, the location is suitably ventilated; otherwise, ventilate the area periodically during use. 4. Connect a supply line to the 3/8 NPT inlet port (lower back panel) and the other end to your nitrogen source. CAUTION Maximum inlet pressure not to exceed 150 psi. 2

4 DIGITAL INFLATOR OPERATING INSTRUCTIONS Decrease Key 2 Increase Key 3 Power On Key 4 Power Off Key 5 Over Pressure Setting (OPS) and Nitrogen Purge Cycles (N2P) Key 6 Battery Charger Input Jack 7 Start / Save Key (Saves OPS and N2P settings) 8 Fill Control Valve (Red Handle) not shown Battery Charging The system contains a rechargeable 2100 mah NiMH battery pack. The smart charger (P/N ) is equipped with Delta V detection and safety timer function/ Connect the charger to the DC input jack located on the control panel. When charging, the LED indicator is RED. When the battery is fully charged, the charger will switch to trickle charge mode and the LED indicator shows GREEN. When the charger output is shorted, the LED indicator shows RED and will blink. Disconnect the charger from the AC outlet when the battery pack is full or the charger is not in use. Auto-Off Power Save The Digital Nitrogen Inflation Equipment will turn off after 10 minutes of no use. Over Pressure Setting (OPS) WARNING When using the OPS function, the sum pressure must not exceed the tire manufacturer s maximum inflation pressure. To set the OPS value, press the OPS/N2P key. Display will flash OPS and the set value alternately. Press the (+) or (-) keys to change the OPS setting. Save your selection by pressing the Start/Save key. The OPS setting can be changed. 3

5 NOTE: To inflate without OPS, leave the OPS setting at zero. The OPS value adds to the final target pressure setting to give the Over Pressure. For example: A final target of 32 psi (220 kpa or 2.2 bar) with an OPS setting of 16 psi (110 kpa or 1.1 bar) gives a sum of 48 psi (330 kpa or 3.3 bar). This sum of 48 psi (330 kpa or 3.3 bar) is the Over Pressure setting for the tire. Using this example, the operation is as follows: Press the Start/Save key momentarily. Inflation will commence and the display will flash the sum pressure value, 48 psi (330 kpa or 3.3 bar) then revert to displaying the actual tire pressure. Tire will inflate to the sum value, beep twice and deflate to the final target pressure. To prevent accidental use of OPS function, the OPS setting returns to zero after power down. Nitrogen Purge (N2P) To set the number of purge cycles, press the OPS/N2P key again. Display will flash N2P and the N2P set value alternately. Press the (+) or (-) keys to change the N2P setting. Save your selection by pressing the Start/Save key. The N2P setting can be changed again when required. Press and hold the Start/Save key for 2 seconds. Release the Start/Save key only when you see N2P in the display. This indicates that the N2P function is activated for this cycle. Tire will deflate and then inflate to the final target pressure, device will beep once and deflate to the N2P deflate lower limit setting, and then inflate to the final target pressure. If 1 N2P cycle was set, then the cycle is now completed. If more than one N2P cycle was set, the purge routine (deflate/inflate) is repeated according to the number of purge cycles set. The deflate lower limit default setting is 3psi. The N2P setting returns to 1 after power down. Converting Air-filled Tires to Nitrogen. 1. Set the final target pressure. Note: The target pressure should be the vehicles recommended tire pressure found on the sticker inside the driver s door jamb or inside the fuel access door. To use the default OPS/N2P (OPS = zero/n2p = 1)settings, it is not necessary to adjust them. 2. Connect hoses to Tires making sure that each chuck is securely attached to the valve stem. 3. Turn the red Fill Control Valve handle to FILL position. 4. Press Start/Save key for 2 seconds. N2P will appear in the display and the nitrogen purge cycle will begin. When the purge cycle is completed, the unit beeps and the target pressure Flashes in the display. To insure tire pressure accuracy, allow 20 seconds for tire pressure to equalize before disconnecting hoses from tires. 5. Turn the red Fill Control Valve handle to STOP position. 6. Disconnect hoses from the tires. Topping Up Tires with Nitrogen To top up tires that have previously been inflated with nitrogen, OPS should be set to zero. 1. Set the final target pressure. 2. Connect hose or hoses to Tires making sure that each chuck is securely attached to the valve stem. 3. Turn the red Fill Control Valve handle to FILL position. 4. Press Start/Save key momentarily. The actual tire pressure will display, the unit will inflate or deflate to the target pressure. When the top up cycle is completed, the unit beeps and the target pressure flashes in the display. To insure tire pressure accuracy, allow 20 seconds for tire pressure to equalize before disconnecting hoses from tires. When topping up a single tire there is no need to wait for pressure equalization to occur. 5. Turn the red Fill Control Valve handle to STOP position. 6. Disconnect hoses from the tires. 4

6 TROUBLESHOOTING THE DIGITAL INFLATOR PROBLEM POSSIBLE CAUSE SOLUTION No display. Dead battery. Recharge/Replace battery. The inflation process does not The tire is deflated below 3 psi. Press the start key. start, even when the pressure The hose connector is faulty. Replace the hose connector. is set and the hose is connected to the tire. The unit deflates very slowly. The deflate tubing or silencer plug is blocked. Contact Branick Industries, Inc The unit no longer beeps. The beeper is damaged. Replace the beeper. The inflation process starts but Low supply pressure. Check the supply pressure. does not complete. ER1 Unstable pressure, faulty hose connector. Replace the hose connector. ER2 Persistent unstable pressure, faulty hose Replace the hose connector. connector. Incorrect supply pressure. Check the supply pressure. ER3 Low supply pressure. Check the supply pressure. ER4 Initial or final pressure is too high, exceeding Disconnect hose connector, the maximum pressure by more than 20 psi. reset processor by switching off the power for a minimum of 5 seconds. If error messages reappears, replace PCB. ER5 Low battery. Recharge the battery. ER6 Program or PCB error. Reset machine by switching off the power for a minimum of 5 seconds. If error messages reappears, replace PCB. ER8 Calibration error. Unit requires calibration, contact Branick Industries, Inc ER9 Automatic calibration check/calibration error. Turn red fill control valve handle to OFF position, reset unit by switching off power for 5 seconds. The ER9 message will clear automatically. If the ER9 message continues to reappear, replace the PCB. 5

7 OWNER S RECORDS Date Installed: Serial number Located on back panel NOTES: 6

8 Branick Industries, Inc. COMMERCIAL WARRANTY This product is warranted by BRANICK INDUSTRIES, INC. to the original user-owner against defective materials or workmanship. During the warranty period, if Branick determines the product to be defective, it will be repaired or replaced (at Branick s option) without charge. Warranty Period 1 year from date of delivery This warranty does not cover defects in the product caused by ordinary wear and tear, abuse, misuse, overloading, accident (including shipping damage), improper maintenance, alteration, or any other cause not the result of defective materials or workmanship. REPLACEMENT IS THE EXCLUSIVE REMEDY FOR DEFECTIVE PRODUCT UNDER THIS WARRANTY. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE OF THIS PRODUCT. BRANICK INDUSTRIES, INC. SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES. BRANICK INDUSTRIES, INC. reserves the right to make changes in the design or construction of our products without obligation to incorporate such changes in products already sold and without notice. Service parts, warranty, and regular repair service for Nitrogen products are available from: BRANICK INDUSTRIES, INC Main Ave. Box 1937 Fargo, North Dakota / Copyright 2006 by Branick Industries, Inc. Printed in U.S.A. 7

INSTRUCTION MANUAL & PARTS BREAKDOWN

INSTRUCTION MANUAL & PARTS BREAKDOWN 24820 Automatic Tire Inflator 3 Modes in One 2347 Circuit Way, Brooksville, Florida, USA 34604 AME INTERNATIONAL Phone: (+1) - 1 352-799-1111 - Toll Phone: (+1) WWW.AMEINTL.NET 877-775-4AME (4263) Fax:

More information

Digital Inflation Equipment 89XDA 89XDD 89XDB 89XDE.

Digital Inflation Equipment 89XDA 89XDD 89XDB 89XDE. Digital Inflation Equipment 89XDA 89XDD 89XDB 89XDE S P E C I F I C A T I O N S I N S T A L L A T I O N O P E R A T I O N S E R V I C E Please read this manual before carrying out any installation or service

More information

Digital Inflation Equipment 89XDZ 89XDX. Please read this manual before carrying out any installation or service procedures.

Digital Inflation Equipment 89XDZ 89XDX.  Please read this manual before carrying out any installation or service procedures. Digital Inflation Equipment 89XDX 89XDZ S P E C I F I C A T I O N S I N S T A L L A T I O N O P E R A T I O N S E R V I C E Please read this manual before carrying out any installation or service procedures.

More information

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE INSTALLATION, OPERATION & MAINTENANCE MANUAL INTERFACE DEVICES, INC. 230 Depot Road, Milford, CT 06460 Ph: (203) 878-4648, Fx: (203) 882-0885, E-mail: info@interfacedevices.com

More information

NTF-515. Operation Manual

NTF-515. Operation Manual NTF-515 Operation Manual RTI Technologies, Inc. 10 Innovation Drive York, Pennsylvania 17402 USA Phone: 717-840-0678 Toll Free: 800-468-2321 Web-site: www.rtitech.com Manual P/N: 035-81474-00 (RevA) TABLE

More information

Portable Compressed CO 2 Regulator

Portable Compressed CO 2 Regulator Portable Compressed CO 2 Regulator 99901 Operating Instructions Distributed exclusively by Harbor Freight Tools. 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our website at: http://www.harborfreight.com

More information

Nitrogen Advantage. Better Tire Pressure Retention. Improved Fuel Economy. Extended Tread Life. Elimination of Oxidation. Reduction in Tire Failures

Nitrogen Advantage. Better Tire Pressure Retention. Improved Fuel Economy. Extended Tread Life. Elimination of Oxidation. Reduction in Tire Failures Nitrogen Advantage nitrogen tire inflation system, 4/7/14/21 CFM Better Tire Pressure Retention Improved Fuel Economy Extended Tread Life Elimination of Oxidation Reduction in Tire Failures 2 The Nitrogen

More information

FRESH AERO OneOP Model RC (Reservoir/tank) Tire Inflating System

FRESH AERO OneOP Model RC (Reservoir/tank) Tire Inflating System FRESH AERO OneOP Model RC (Reservoir/tank) Tire Inflating System For inflating aircraft tires and all types of other vehicle tires and air operated devices Manual The Steelebrook Group Where Imagination

More information

Tire Inflation Cage Kit For servicing only single piece automotive, and most light truck tire/wheel assemblies

Tire Inflation Cage Kit For servicing only single piece automotive, and most light truck tire/wheel assemblies Tire Inflation Cage Kit 85608214 For servicing only single piece automotive, and most light truck tire/wheel assemblies This is a supplement to your operating manual and covers the setup and use of the

More information

Model ASSEMBLY and OPERATING INSTRUCTIONS

Model ASSEMBLY and OPERATING INSTRUCTIONS QUICK CHANGE AIR BRUSH KIT Model 93506 ASSEMBLY and OPERATING INSTRUCTIONS Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission Oaks Blvd.,

More information

6 digital caliper with case

6 digital caliper with case 6 digital caliper with case Model 98563 Set up And Operating Instructions Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly

More information

Manual. FRESH AERO OneOP Model PC (Portable Compressors) Tire Inflator. Where Imagination Meets Innovation

Manual. FRESH AERO OneOP Model PC (Portable Compressors) Tire Inflator. Where Imagination Meets Innovation FRESH AERO OneOP Model PC (Portable Compressors) Tire Inflator For inflating aircraft tires and all types of other vehicle tires and air operated devices Manual The Fresh Aero Group Where Imagination Meets

More information

NITROGEN INFLATION SYSTEM NG-4, NG-6, NG-12, NG-18

NITROGEN INFLATION SYSTEM NG-4, NG-6, NG-12, NG-18 NITROGEN OPERATING INSTRUCTIONS NITROGEN INFLATION SYSTEM NG-4, NG-6, NG-12, NG-18 READ INSTRUCTIONS THOROUGHLY BEFORE OPERATING 3451 S. 40th Street Phoenix, AZ 85040 602.437.5020 800.223.4540 www.tsissg.com

More information

Pressure Relief Valve Instruction Manual

Pressure Relief Valve Instruction Manual CVR3-M0_062017 Pressure Relief Valve Instruction Manual MODEL: CVR3 SFA Companies 10939 N. Pomona Ave. Kansas City, MO 64153 Tel: 888-332-6419 * Fax: 816-448-2142 E-mail: sales@bvahydraulics.com Website:

More information

EM151/EM201. Electronic Manometer - + INSTRUCTION MANUAL. EM201 PSI

EM151/EM201. Electronic Manometer - + INSTRUCTION MANUAL.    EM201 PSI EM151/EM201 Electronic Manometer INSTRUCTION MANUAL - + PSI EM201 www.ueitest.com Email: info@ueitest.com TABLE OF CONTENTS Safety Rules..............................................2 Features.................................................3

More information

Owners Manual Models: 075-AQF-CX. Aquatrol Backwashing Catalytic Carbon Filter. Visit us online at.

Owners Manual Models: 075-AQF-CX. Aquatrol Backwashing Catalytic Carbon Filter.  Visit us online at. Visit us online at www.uswatersystems.com Aquatrol Backwashing Catalytic Carbon Filter Owners Manual Models: 075-AQF-CX REVISION # 1.0 REVISION DATE October 11, 2017 US Water Systems, Inc. 1209 Country

More information

PC1131 Electric Air Compressor

PC1131 Electric Air Compressor Senco Products Inc. 8485 Broadwell Road Cincinnati, Ohio 45244 PC1131 Electric Air Compressor Operating Instructions C US 2006, 2007 by Senco Products, Inc. Warnings for the safe use of this tool are included

More information

Installation Instructions Air Compressor Part # 2780, 2781

Installation Instructions Air Compressor Part # 2780, 2781 Note: It is essential that the operator of this product read and understand the contents of this manual before installing and using this product. Parts Included Qty Parts Included Qty Compressor 1 Coil

More information

- GAS REGULATOR - COMPACT STYLE

- GAS REGULATOR - COMPACT STYLE INSTRUCTIONS FOR USE - GAS REGULATOR - COMPACT STYLE Preset at 50 or 60 psi Rx ONLY GR - XXX - [(TT) (UU) - (XX)(Z)] GR XXX (TT) (UU) (XX) (Z) Gas Connection Outlet Flowrate Addition Outlet Additional

More information

INFLATION STATION. Cordless OWNER S MANUAL MODEL NO: RCP-C65B

INFLATION STATION. Cordless OWNER S MANUAL MODEL NO: RCP-C65B [ACT 050] Manual E 4/4/06 4:34 PM Page 1 Cordless INFLATION STATION OWNER S MANUAL MODEL NO: RCP-C65B KEEP THE ORIGINAL BOX, PACKAGING AND RECEIPT. BEFORE OPERATING THIS UNIT, READ THE MANUAL THOROUGHLY

More information

Issue OWNER S MANUAL. GAMMA RACQUET SPORTS GAMMA Sports All Rights Reserved

Issue OWNER S MANUAL. GAMMA RACQUET SPORTS GAMMA Sports All Rights Reserved OWNER S MANUAL CONTENTS PARTS LIST.. 2 ASSEMBLY INSTRUCTIONS.. 3 SWING WEIGHT TEST.. 4 RACQUET BALANCE TEST.. 5 RACQUET WEIGHT TEST.. 6 CALIBRATION - SWING WEIGHT.. 7 CALIBRATION - WEIGHT SCALE.. 8 MACHINE

More information

PPS PORTABLE POWER SUPPLY

PPS PORTABLE POWER SUPPLY PPS User Manual Rev 1-2015 ENG MASTER PPS PORTABLE POWER SUPPLY Disclaimer About ActSafe Safety messages and warnings Product safety System description Pre-use inspection and connection General safety

More information

IMPORTANT SAFETY INFORMATION

IMPORTANT SAFETY INFORMATION WARNING SYMBOLS AND DEFINITIONS This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury

More information

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician. USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS CAUTION Federal (USA) law restricts this device to sale by or on the order of a physician. RECEIVING / INSPECTION Remove the Precision Medical,

More information

RK LEL Sample Draw Aspirator Adapter Operator s Manual

RK LEL Sample Draw Aspirator Adapter Operator s Manual 30-0951RK LEL Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0017RK Revision: A Released: 6/2/10 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment

More information

Portable Gas Monitor GX User Maintenance Manual (H4-0050)

Portable Gas Monitor GX User Maintenance Manual (H4-0050) H4E-0050 Portable Gas Monitor GX-8000 User Maintenance Manual (H4-0050) Need of Maintenance and Servicing This gas monitor must be maintained in a normal state at all times to prevent accidents due to

More information

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc. Advanced Calibration Designs, Inc. Calibration Gas Instrument INSTRUCTION MANUAL Release I www.goacd.com Instruction Manual Gas Generator Release I TABLE OF CONTENTS I. General Description Page 2 II. Start-Up

More information

8 TON AIR/MANUAL FLAT BOTTOM JACK

8 TON AIR/MANUAL FLAT BOTTOM JACK 8 TON AIR/MANUAL FLAT BOTTOM JACK Model 95967 OPERATION INSTRUCTIONS Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission Oaks Blvd., Camarillo,

More information

Yoke Block Instruction Manual

Yoke Block Instruction Manual Yoke Block Instruction Manual ! WARNING IMPORTANT: READ MANUAL COMPLETELY BEFORE OPERATING THIS DEVICE This manual contains instructions on periodically required checks to be performed by the user. These

More information

20 Ton Air Over Hydraulic Jack

20 Ton Air Over Hydraulic Jack 20 Ton Air Over Hydraulic Jack Model 95553 Assembly And Operation Instructions Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly

More information

WARRANTY, QUICK START GUIDE

WARRANTY, QUICK START GUIDE WARRANTY, QUICK START GUIDE ONE-YEAR LIMITED PRODUCT WARRANTY BABOLAT warrants to the original purchaser that the BABOLAT PLAY PURE DRIVE (the Product ) is free from defects in material or workmanship,

More information

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

ACRYLIC FLOW METERS 0-30, 0-70 & LPM ACRYLIC FLOW METERS 0-30, 0-70 & 0-120 LPM ASSEMBLY INSTRUCTIONS & INSTRUCTIONS FOR USE R219P86 (0-120LPM) R219P87 (0-70LPM) R219P88 (0-30 LPM) R138P11 Rev. D TABLE OF CONTENTS: 1.0 PRODUCT OVERVIEW...1

More information

RGC-IR Remote Gas Calibrator for IR400

RGC-IR Remote Gas Calibrator for IR400 Remote Gas Calibrator for IR400 The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically authorized in writing by

More information

Owner s Manual & Safety Instructions

Owner s Manual & Safety Instructions Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s

More information

HoverJack. Air Patient Lift. Equipment Manual. From HoverTech International. Issued: June 1,

HoverJack. Air Patient Lift. Equipment Manual. From HoverTech International. Issued: June 1, HoverJack Air Patient Lift From HoverTech International Equipment Manual Issued: June 1, 2008 www.hovermatt.com HOVERJACK AIR PATIENT LIFT EQUIPMENT MANUAL TABLE OF CONTENTS Instructions for Use Page 1&

More information

AND OPERATION INSTRUCTIONS

AND OPERATION INSTRUCTIONS ADI 2111-D Certified ISO 9001 MEDICAL FLOWMETER (Back Pressure Compensated Thorpe Tube) INSTALLATION AND OPERATION INSTRUCTIONS Before Installing or Operating, Read and Comply with These Instructions Controls

More information

The Univentor 1250 Anaesthesia Unit

The Univentor 1250 Anaesthesia Unit THE UNIVENTOR 1200/1250 ANAESTHESIA UNIT The Univentor 1250 Anaesthesia Unit TABLE OF CONTENTS EDITION 1 Section 1 - WARRANTY & SERVICE 1.1. WARRANTY 2 1.2. DAMAGED SHIPMENTS 2 1.3. SERVICE 2 Section 2

More information

60 farm jack. Distributed exclusively by Harbor Freight Tools Mission Oaks Blvd., Camarillo, CA 93011

60 farm jack. Distributed exclusively by Harbor Freight Tools Mission Oaks Blvd., Camarillo, CA 93011 60 farm jack 66183 Set up And Operating Instructions Distributed exclusively by Harbor Freight Tools. 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our website at: http://www.harborfreight.com Read

More information

ULTRA-LIGHT DUTY ONBOARD AIR SYSTEM

ULTRA-LIGHT DUTY ONBOARD AIR SYSTEM ULTRA-LIGHT DUTY ONBOARD AIR SYSTEM PART NO. 10000 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using

More information

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician. U S E R M A N U A L 1600 SERIES OXYGEN REGULATOR 168715G (Shown) SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician. 300 Held Drive Tel: (+001) 610-262-6090

More information

Wireless Belt Pack BP Conductor with Radio Transmit

Wireless Belt Pack BP Conductor with Radio Transmit Wireless Belt Pack BP5-10 5-Conductor with Radio Transmit Operation Manual 7340 SW Durham Road Portland, OR 97224 USA Phone: 503-684-6647 1-800-527-0555 Fax: 503-620-2943 email: sales@firecom.com www.firecom.com

More information

J Air and Water Kit Instructions Part# 02584

J Air and Water Kit Instructions Part# 02584 J Air and Water Kit Instructions Part# 02584 Unpacking Please open and inspect your package upon receipt. Your package was packed with great care and all the necessary packing materials to arrive to you

More information

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity WATER HEATER THERMAL EXPANSION TANKS Owner s Manual Safety Instructions Installation Maintenance Warranty Models: 2-5 Gallon Capacity Thank You for purchasing this Thermal Expansion Tank. Properly installed

More information

User s Guide. CO2 & O2 Controller for miniature incubators

User s Guide. CO2 & O2 Controller for miniature incubators CO2 O2 Control User s Guide CO2 & O2 Controller for miniature incubators Precise CO2 & O2 Control throughout the experiment Media ph control Compatible with any perfusion system Miniature incubators for

More information

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data Technical Services: Tel: (800) 381-312 / Fax: (800) 71-5500 Customer Service/Sales: Tel: (215) 362-0700 / (800) 523-6512 Fax: (215) 362-5385 Model B-1 Pipe Line Strainer 3,, 6 & 8 Inch (DN80, DN100, DN150

More information

INSTRUCTION MANUAL. Includes: OPERATION SETUP USE & CARE SERVICE. SPORTS ATTACK LLC

INSTRUCTION MANUAL. Includes: OPERATION SETUP USE & CARE SERVICE. SPORTS ATTACK LLC Electronic Baseball Pitching Machine baseball INSTRUCTION MANUAL PART NO. B-EHABA-100 REV022111 INSTRUCTION MANUAL Includes: OPERATION SETUP USE & CARE SERVICE SPORTS ATTACK LLC 800-717-4251 www.sportsattack.com

More information

RoVent Jr. Automatic Ventilator Volume & Pressure Controlled. User s Guide

RoVent Jr. Automatic Ventilator Volume & Pressure Controlled. User s Guide RoVent Jr. Automatic Ventilator Volume & Pressure Controlled User s Guide TABLE OF CONTENTS Introduction... 1 System Components...1 Navigating RoVent Jr.... 2 Touchscreen... 2 Control... 2 Display Options...

More information

Handi+N2 OPERATING MANUAL & INSTRUCTIONS FOR USE. R218M06 Industrial. R218M06 Rev. E

Handi+N2 OPERATING MANUAL & INSTRUCTIONS FOR USE. R218M06 Industrial. R218M06 Rev. E E N2 Handi+N2 OPERATING MANUAL & INSTRUCTIONS FOR USE R218M06 Industrial R218M06 Rev. E Maxtec TEL (801) 748. 5355 2305 S 1070 W FAX (801) 270. 5590 Salt Lake City, Utah 84119 www.maxtec.com USA CLASSIFICATION

More information

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO 250C-IG COMPRESSOR KIT 12V PART NO. 25050 250C-IG COMPRESSOR KIT 24V PART NO. 25058 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual

More information

200 PSI HIGH-FLOW AIR SOURCE KIT

200 PSI HIGH-FLOW AIR SOURCE KIT 200 PSI HIGH-FLOW AIR SOURCE KIT 50% Duty Compressor on 2.0 Gallon Air Tank PART NO. 20008 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of

More information

Model SM/PL Series. Calibration Guide. Precision Loads. Anritsu Company 490 Jarvis Drive Morgan Hill, CA USA

Model SM/PL Series. Calibration Guide. Precision Loads. Anritsu Company 490 Jarvis Drive Morgan Hill, CA USA Calibration Guide Model SM/PL Series Precision Loads Anritsu Company 490 Jarvis Drive Morgan Hill, CA 95037-2809 USA Part Number: 10100-00056 Revision: B Published: January 2010 Copyright 2009-2010 Anritsu

More information

Accu-Tab PowerBase 3012AT by Axiall Corporation

Accu-Tab PowerBase 3012AT by Axiall Corporation Accu-Tab PowerBase 3012AT by Axiall Corporation Installation and Operating Instructions DANGER: DO NOT MIX CHEMICALS! The PowerBase 3012AT chlorinator system is designed for use with Axiall Corp. approved

More information

PORTER INSTRUMENT COMPANY, INC.

PORTER INSTRUMENT COMPANY, INC. PORTER INSTRUMENT COMPANY, INC. MXR FLOWMETER Instructions and Safety Considerations MXR Models of Porter Conscious Sedation Flowmeters and Bag Tee (Accessory) Wall Mount Models: 2000 and 2000-OS, 3000

More information

Sweeper Dual Control. Automatic Sweeper Switching System SW SERIES SWEEPERS SW-4815 SW-4820 SW-4825 MAGUIRE PRODUCTS INC.

Sweeper Dual Control. Automatic Sweeper Switching System SW SERIES SWEEPERS SW-4815 SW-4820 SW-4825 MAGUIRE PRODUCTS INC. MAGUIRE PRODUCTS INC. SW SERIES SWEEPERS For SW Series Sweeper Models: SW-4815 SW-4820 SW-4825 Sweeper Dual Control Automatic Sweeper Switching System INSTRUCTION AND OPERATION MANUAL Copyright Maguire

More information

Everyday INFLATION STATION CORDLESS

Everyday INFLATION STATION CORDLESS [ACT 050] Manual E 3/30/06 9:43 AM Page 3 Everyday INFLATION STATION CORDLESS OWNER S MANUAL MODEL NO: W03A-54 KEEP THE ORIGINAL BOX, PACKAGING AND RECEIPT. BEFORE OPERATING THIS UNIT, READ THE MANUAL

More information

HAI UPB 15A Relay Switch and Auxiliary Switch Installation and Operating Instructions

HAI UPB 15A Relay Switch and Auxiliary Switch Installation and Operating Instructions HAI UPB 15A Relay Switch and Auxiliary Switch Installation and Operating Instructions For the following Models: 40A00-1 HAI 15A Relay Switch (referred to as HAI UPB Wall Switch, in this document), and

More information

2 GAL AIR COMPRESSOR OPERATOR S MANUAL 1/3HP/2-GALLON IMPORTANT: READ THIS OPERATOR S MANUAL BEFORE USING

2 GAL AIR COMPRESSOR OPERATOR S MANUAL 1/3HP/2-GALLON IMPORTANT: READ THIS OPERATOR S MANUAL BEFORE USING ITEM# AT01101 SKU# 207-1525 OPERATOR S MANUAL 1/3HP/2-GALLON 2 GAL AIR COMPRESSOR IMPORTANT: READ THIS OPERATOR S MANUAL BEFORE USING Toll Free Helpline: 1-888-899-0146 Versions 01 TABLE OF CONTENTS SAFETY

More information

Operation Manual. Pro CO 2 Analyzer. Carbon Dioxide Analyzer. Rev

Operation Manual. Pro CO 2 Analyzer. Carbon Dioxide Analyzer. Rev Operation Manual Pro CO 2 Analyzer Carbon Dioxide Analyzer Rev. 10.17 Quick Reference Guide READ ENTIRE MANUAL BEFORE USE 1. To switch on, hold the On/Off button until the display powers up. 2. To turn

More information

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO 250C-IG COMPRESSOR KIT 12V PART NO. 25050 250C-IG COMPRESSOR KIT 24V PART NO. 25058 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual

More information

Golf Performance Monitors. PureContact Operating Guide. Version of 9

Golf Performance Monitors. PureContact Operating Guide. Version of 9 PureContact Operating Guide Version 5.1 www.zelocity.com 1 of 9 PureContact Metrics: Measured Ball Velocity Carry Distance Other PureContact Features: Instantly, Accurately Displays & Records Critical

More information

2 Gallon, 100 PSI Oilless

2 Gallon, 100 PSI Oilless 2 Gallon, 100 PSI Oilless Air Compressor Model 47407 Assembly And Operation Instructions Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission

More information

Please Do Not Return This Product To The Store!

Please Do Not Return This Product To The Store! MODEL NUMBER: GM000W - GAMEMAKER TORCH O W N E R ' S M A N U A L PLEASE READ AND FOLLOW THIS MANUAL IN ITS ENTIRETY BEFORE USE. DOING SO WILL PROVIDE HELPFUL HINTS THAT WILL AID IN GETTING MAXIMUM USE

More information

U S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified

U S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified U S E R M A N U A L AIR FLOWMETER MODELS: 1MFA2001 (shown) 1MFA9001 ISO 13485 Certified Authorized Your EU local Representative: distributor: EMERGO EUROPE, INC. Molenstraat 15 2513866 BH -624 The -3952

More information

PRESSURE COMPARATOR 10000PSI 700bar. Operator Instructions CRYSTAL. engineering corporation

PRESSURE COMPARATOR 10000PSI 700bar. Operator Instructions CRYSTAL. engineering corporation PRESSURE COMPARATOR GauGeCaLXP 10000PSI 700bar Operator Instructions Page 2 GaugeCalXP Operator Instructions PRESSURE is Our BUSINESS Introduction Thank you for purchasing a GaugeCalXP Pressure tor from

More information

MANUAL: IN-LINE PIVOT GAUGE IN-LINE GAUGE

MANUAL: IN-LINE PIVOT GAUGE IN-LINE GAUGE MANUAL: IN-LINE PIVOT GAUGE IN-LINE GAUGE INSTRUCTIONS FOR INSTALLATION, SAFE OPERATION AND MAINTENANCE WARNING Understand manual before use. Operation of this device without understanding the manual and

More information

COMPACT METAL bender 99826

COMPACT METAL bender 99826 COMPACT METAL bender 99826 Set up And Operating Instructions Distributed exclusively by Harbor Freight Tools. 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our website at: http://www.harborfreight.com

More information

PS-425 Pitot-Static/Air Data Tester

PS-425 Pitot-Static/Air Data Tester PS-425 Pitot-Static/Air Data Tester OPERATION AND MAINTENANCE MANUAL Preston Pressure LLC 580-286-3161 prestonpressure.com Revision 1, February 16, 2011 PRESTON PRESSURE LLC PS-425 USER AND MAINTENANCE

More information

PTG100 Precision Test Gauge

PTG100 Precision Test Gauge PTG100 Precision Test Gauge User Manual PD1007 Rev B 03/28/2014 Palmer Instruments Inc. 234 Old Weaverville Road Asheville, NC 28804 Toll Free: 800-421-2853 Phone: 828-658-3131 Fax: 828-658-0728 Email:

More information

SDM-2012 Docking Station Standalone Configuration Operator s Manual

SDM-2012 Docking Station Standalone Configuration Operator s Manual SDM-2012 Docking Station Standalone Configuration Operator s Manual Part Number: 71-0254RK Revision: P5 Released: 10/5/12 www.rkiinstruments.com Warranty RKI Instruments, Inc. warrants gas alarm equipment

More information

pneumatic dent puller

pneumatic dent puller Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s

More information

Push-To-Set Intermittent Suction Unit (PTS-ISU) Instructions for Use

Push-To-Set Intermittent Suction Unit (PTS-ISU) Instructions for Use Push-To-Set Intermittent Suction Unit (PTS-ISU) Instructions for Use F H M L F H M L MEDICAL VACUUM Analog Digital 8700-0000-000 (Rev.7) 05/2010 Regulator Identification Push-To-Set TM Intermittent Suction

More information

PM105 PRESSURE METER USER S MANUAL

PM105 PRESSURE METER USER S MANUAL PM105 PRESSURE METER USER S MANUAL Manual revision: 15 March, 2001 SCSMANP015 Copyrighted 2001 Thank you for purchasing a Tek Know pressure meter. The Tek Know products are manufactured by Scan-Sense AS

More information

Gas Countertop Hot Plates

Gas Countertop Hot Plates Gas Countertop Hot Plates This manual contains important information regarding your Patriot unit. Please read the manual thoroughly prior to equipment set-up, operation and maintenance. Failure to comply

More information

AIR/OXYGEN BLENDER INSTRUCTION MANUAL

AIR/OXYGEN BLENDER INSTRUCTION MANUAL BIO-MED DEVICES AIR/OXYGEN BLENDER INSTRUCTION MANUAL CATALOG #2120 REV 042203 BIO-MED DEVICES INC. 1445 BOSTON POST ROAD, GUILFORD, CT 06437 (203) 458-0202 FAX (203) 458-0440 www.biomeddevices.com TABLE

More information

Owner s Manual & Safety Instructions

Owner s Manual & Safety Instructions Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s

More information

INSTRUCTION MANUAL MANUAL INFLATION BLOOD PRESSURE MONITOR

INSTRUCTION MANUAL MANUAL INFLATION BLOOD PRESSURE MONITOR INSTRUCTION MANUAL MANUAL INFLATION BLOOD PRESSURE MONITOR Model HEM-412C TABLE OF CONTENTS Introduction 3 Know Your Unit 4 Quick Reference Guide 5 Battery Installation/Replacement 6 How To Apply The Arm

More information

Getting to know your Sureshotgps micro V3

Getting to know your Sureshotgps micro V3 Getting to know your Sureshotgps micro V3 Battery State Symbol Satellite Signal Shows distance to front, centre and rear of each green Hole Number Real Time Power on and Enter Key Down (backward) Key 1

More information

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury. 2 GALLON AIR COMPRESSOR Model: 7517 DO NOT RETURN TO STORE. Please CALL 800-348-5004 for parts and service. CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials

More information

PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual

PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual ! WARNING IMPORTANT: READ MANUAL COMPLETELY BEFORE OPERATING THIS DEVICE This manual contains instructions on periodically required checks to be

More information

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS 18 GAUGE 2 INCH BRAD NAILER Model: 7555 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement, or other masonry.

More information

OPERATION INSTRUCTIONS

OPERATION INSTRUCTIONS TAS 1000 OPERATION INSTRUCTIONS DOCUMENT 1000-401 DATE: April 29/2011 REV. D PLEASE READ INSTRUCTIONS COMPLETELY BEFORE PROCEEDING WITH INSTALLATION Instrument Corporation P.O. Box 122 Fort Erie, Ontario

More information

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS 18 GAUGE 1-1/4 INCH BRAD NAILER Model: 7611 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement, or other masonry.

More information

Installation and Operating Instructions

Installation and Operating Instructions Installation and Operating Instructions Neptune Caisson Pump Section 1 Shipment Inspection........Page 2 Section 2 Pre-Installation Checklist....Page 3 Section 3 Installation..............Page 4 Section

More information

UNIVERSAL GAS FRYER Instruction Manual Model #8065NS

UNIVERSAL GAS FRYER Instruction Manual Model #8065NS Part No. 88847 Revised: August 2004 UNIVERSAL GAS FRYER Instruction Manual Model #8065NS Cincinnati, OH 45241-4807 USA GAS SAFETY PRECAUTIONS OPERATING INSTRUCTIONS UNPACKING AND ASSEMBLY After unpacking

More information

SC HYDRAULIC ENGINEERING CORPORATION

SC HYDRAULIC ENGINEERING CORPORATION Designers and Manufacturers of Hydraulic and Pneumatic Equipment SC HYDRAULIC ENGINEERING CORPORATION 1130 Columbia Street - Brea, California 92821 - USA Phone (714) 257-4800 - Fax (714) 257-4810 V FLOW

More information

BOC: Living healthcare. Manual. LIV IQ BOC Integrated Valve with digital display portable delivery system for Medical Oxygen. BOC: Living healthcare

BOC: Living healthcare. Manual. LIV IQ BOC Integrated Valve with digital display portable delivery system for Medical Oxygen. BOC: Living healthcare BOC: Living healthcare Manual LIV IQ BOC Integrated Valve with digital display portable delivery system for Medical Oxygen. BOC: Living healthcare 02 Manual LIV IQ Oxygen Manual LIV IQ Oxygen 03 Contents.

More information

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL 2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL Model: 52024 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement,

More information

21 Gallon. Model Visit our website at:

21 Gallon. Model Visit our website at: 21 Gallon Cast Iron VERTICAL Oil-lubricated AIR COMPRESSOR Model 94667 OPERATING INSTRUCTIONS Visit our website at: http://www.harborfreight.com Read this material before using this product. Failure to

More information

Owner s Manual & Safety Instructions

Owner s Manual & Safety Instructions Owner s Manual & Safety Instructions Save Save This This Manual Manual Keep manual for the safety warnings and precautions, assembly, Keep manual for the safety warnings and precautions, assembly, operating,

More information

AUTO PUMP STATUS CENTER

AUTO PUMP STATUS CENTER INSTRUCTION MANUAL AUTO PUMP STATUS CENTER PRESSURE ONLY MODEL #: 091-198-12-AP File: IM_091-198-12-AP_revD.indd Rev: D, pg 3 WD Revised By: PSS Date: 2-01-2016 3 YEAR WARRANTY INTRODUCTION The Auto Pump

More information

OPERATION. Zinc Sprayer. For Maximum Working Pressure see page 2. Rev. E

OPERATION. Zinc Sprayer. For Maximum Working Pressure see page 2. Rev. E OPERATION 309362 Rev. E U.S. Patent Pending Related manuals Zinc Sprayer....... 309340 List of Models, page 2 For Maximum Working Pressure see page 2....... 309092, 308438.. 307049.. 309342 INSTRUCTIONS

More information

CONSERVATORY DIAGNOSTIC TOOLS TO MEASURE BUILDING PERFORMANCE

CONSERVATORY DIAGNOSTIC TOOLS TO MEASURE BUILDING PERFORMANCE for the DG-700 Pressure and Flow Gauge The ENERGY CONSERVATORY DIAGNOSTIC TOOLS TO MEASURE BUILDING PERFORMANCE The Energy Conservatory 2801 21 st Ave. S., Suite 160 Minneapolis, MN 55407 Ph.: (612) 827-1117

More information

User s Guide. VetPro 1000 Mobile Dental Delivery System. For Models:

User s Guide. VetPro 1000 Mobile Dental Delivery System. For Models: VetPro 1000 Mobile Dental Delivery System For Models: 8000-001 8000-002 8000-003 8000-004 8000-005 8000-006 8000-007 8000-008 User s Guide 003-1879-00 Rev L Product Information (The information below is

More information

Operating Manual. Model 25200B/25202B Refrigerant Recovery Unit. (Not for use in automotive R-134a applications)

Operating Manual. Model 25200B/25202B Refrigerant Recovery Unit. (Not for use in automotive R-134a applications) Operating Manual Model 25200B/25202B Refrigerant Recovery Unit (Not for use in automotive R-134a applications) ROBINAIR Refrigerant Recovery Unit Model: 25200B /25202B Series Type of Equipment: Recovery

More information

Operation Manual. Pro O 2 Alarm TM. Oxygen Analyzer. Rev

Operation Manual. Pro O 2 Alarm TM. Oxygen Analyzer. Rev Operation Manual Pro O 2 Alarm TM Oxygen Analyzer Rev. 08.17 If you have any questions on this equipment please contact Technical Support at: Nuvair 1600 Beacon Place Oxnard, CA 93033 Phone: 805-815-4044

More information

Ocean Technology Systems ComBox

Ocean Technology Systems ComBox Undersea Systems International, Inc. dba Ocean Technology Systems ComBox Silver Bullet User s Guide Technology in Depth - NOTICE - This manual and the information contained herein are provided for use

More information

SAFETY MEASURES. These important guidelines should always be followed to work safely with the PRIMATECH pneumatic stapler model Q180:

SAFETY MEASURES. These important guidelines should always be followed to work safely with the PRIMATECH pneumatic stapler model Q180: PRIMATECH PNEUMATIC 18GA STAPLER Q180 The pneumatic flooring stapler Q180 is a professional precision tool specially developed for the installation of most of 3/8" to 5/8" solid and engineered hardwood

More information

2-Quart (1.9 Liter) Pressure Cup

2-Quart (1.9 Liter) Pressure Cup Instructions-Parts 2-Quart (1.9 Liter) Pressure Cup 312111A For controlling atomizing air and fluid pressure for any pressure feed manual spray gun when more than one quart of fluid will be used. 288776

More information

623 Series Dome Load Regulators

623 Series Dome Load Regulators ADI 3202C Certified ISO 9001 623 Series Dome Load Regulators INSTALLATION AND OPERATION INSTRUCTIONS This Equipment is intended to be installed and operated by trained personnel. Before Installing or Operating,

More information

Machine Cutting Torches Series 4700

Machine Cutting Torches Series 4700 ADI 1580-E Certified ISO 9000 Machine Cutting Torches Series 4700 INSTRUCTIONS Before Installing, Operating or Servicing Read and Comply With These Instructions This symbol on the product means the product

More information