SAFETY DECALS FOR THE AGRICULTURAL INDUSTRY
|
|
- Horatio Bradley
- 6 years ago
- Views:
Transcription
1 SAFETY DECALS FOR THE AGRICULTURAL INDUSTRY AG IDA WICHITA, KS (FAX) JANUARY 2016 PRICING AG A G AG 23 3
2
3 AONIA DECALS ISCELLANEOUS DECALS SAF99 TRANSFER INSTRUCTIONS 2 x R 6 CAUTION AONIA (Q 26) (Q 26243) SAF24R 24 7 FILL HOSE 2 SAFETY PRESSURE GAUGE OUT OUT TO REGULATOR FLOAT GAUGE BLEEDER 24G NURSE TANK HOSE APPL HOSE COPRESSOR NURSE TANK APPLICATOR TANK A. Hose Hook Up Use only approved ammonia quipment in first-class condition. your dealer immediately in case of leaks, malfunction or exceptional wear. Do not tamper with valves or equipment except as instructed. Stay up wind when filling. Sniff, don t breathe deeply when approaching area. 24 Ammonia gloves and goggles should be worn transferring ammonia. Keep out of a irect line from openings on all valves and fittings. 1. CHECK HOSE AND CONNECTIONS FOR DIRT, AND S FOR CONNECTION SEAL WASHERS. Before removing hoses or parts, be positive all pressure is out of the system. 2. CONNECT NURSE TANK FILL HOSE (7) HAND TIGHT ONLY TO APPLICATOR FILL (1). Never pick up a hose by the valve handwheel nor allow valve contact with ground. 3. CONNECT APPLICATOR HOSE (8) TO APPLICATOR (4) HAND TIGHT ONLY. (Q 26242) SAF24G 4. CONNECT NURSE TANK HOSE (9) TO NURSE TANK (6) HAND TIGHT ONLY. 21R A. To Fill Applicator Tank 1. CHECK TO BE SURE ALL BLEEDERS ON S ARE CLOSED. 2. THEN OPEN S (SLOWLY AT FIRST) IN THE FOLLOWING ORDER: 1, 2, 4, 3, 10,, AND START COPRESSOR. IT AY TAKE A SHORT PERIOD OF TIE FOR THE COPRESSOR TO BUILD UP. 6 CAUTION AONIA LARGE VOLUES OF FRESH WATER CONSTITUTE THE BASIC FIRST AID TREATENT FOR AONIA BURNS (Q 26237) SAF21R 2 ANHYDROUS AONIA 4. PRESSURE IN THE NURSE TANK BEFORE THE APPLICATOR TANK WILL START TO FILL. A. To Disconnect Hose 1. FILL APPLICATOR TANK TO ONLY 8% AS SHOWN BY FLOAT GAUGE OR BY FIXED LEVEL BLEED BY SPEWING OF AONIA. 2. SHUT OFF COPRESSOR. THEN CLOSE S IN THE FOLLOWING ORDER: NO. 10, 6,, 3, 4, 2, AND OPEN BLEEDERS ON S. BE SURE HOLE IS AWAY FRO YOU, AND ALLOW TO EPTY. 4. DISCONNECT HOSES AND REPLACE PROTECTIVE CAP.. CAREFULLY RACK HOSES ON APPLICATOR AND NURSE TANK TO AVOID KINKING AND DRAGGING ON GROUND. 1. SET REGULATOR ACCORDING TO AKE, FOR DESIRED OUTPUT, SWATH, TRACTOR SPEED, ETC. 2. START TRACTOR OVING - DROP KNIVES TO DESIRED DEPTH AND TURN ON NH3. 3. AINTAIN CONSTANT SPEED - SHUT OFF NH3 ONE TRACTOR LENGTH FRO ROW END - LIFT KNIVES BEORE TURNING. 4. PERIODICALLY CHECK KNIFE HOSED FOR FROSTING WHICH INDICATED FULL FLOW. 6. ADJUST REGULATOR AS NECESSARY AND CLEAN STRAINERS ACCORDING TO INSTRUCTIONS. a. Immediately flood affected area with water. b. Remove affected clothing. c. Reflood and leave affected skin to open to air. Immediately flood eye with abundance of fresh water for at least 1 minutes and repeat. Rinse, gargle and drink large quantities of water or lemonade. ove to fresh air. Avoid violent and unskilled artificial respiration. Neutralize ammonia with abundance of vinegar, or lemon juice. Follow with raw eggs, cream or olive oil to protect tissues. 21G (Q 26336) SAF21G 22R (Q 26239) SAF22R 22G (Q 26238) SAF22G 8777 (Q 26249) SAF ANHYDROUS AONIA 4 ANHYDROUS AONIA 4 ANHYDROUS AONIA 2 STRAIGHT ANHYDROUS AONIA LIQUEFIED Green on White 1
4 AONIA DECALS ISCELLANEOUS DECALS R (Q 2624) SAFR 2" CURVED ANHYDROUS AONIA 4912 (Q 26218) SAF4912 QUICK COUPLING (Operating Instructions) 4 x 8 INIU 0 G (Q 26244) SAFG 2" CURVED ANHYDROUS AONIA WARNING FAILURE TO FOLLOW THESE INSTRUCTIONS AY RESULT INSERIOUS BODILY HAR. 23R (Q 26241) SAF23R 4" CURVED ANHYDROUS AONIA ATTENTION: QUICK COUPLING OPERATING INSTRUCTIONS CAUTION 23G (Q 26240) SAF23G 4" CURVED ANHYDROUS AONIA NEVER ATTEPT TO CONNECT OR DISCONNECT WITH PRESSURE ON EITHER HALF OF THE COUPLING AS HAZARDOUS AONIA SPRAY AY RESULT. IF DISCONNECT OCCURS DURING OPERATION, CLOSE TANK WITHDRAWAL & TANK SUPPLY HOSE, BLEED PRESSURE FRO COUPLER & SUPPLY HOSE & THEN CONNECT COUPLING. CONNECT FLAABLE/NON-FLAABLE PLACARD DECALS 06- (Q 26233) SAF06 PLACARD /2 DIAONDh CAUTION! DO NOT OPEN TANK WITHDRAWAL UNTIL ALL CONNECT PROCEDURE STEPS ARE COPLETED. 1. PUT ON GLOVES AND GOGGLES. 2. SLOWLY OPEN BLEED S ON TANK SUPPLY HOSE, APPLICATOR ETER & COUPLER. BE SURE BLEED PORT IS DIRECTED AWAY FRO YOUR FACE & BODY. 3. ATTACH THE TANK SUPPLY HOSE TO THE COUPLING NIPPLE, PULL HOSE SHARPLY TO DISCONNECT NIPPLE FRO COUPLER. 4. INSPECT COUPLER & NIPPLE TO AKE SURE POPPET S ARE CLOSED & WILL DEPRESS & RELEASE FREELY. CLEAN OUT DIRT FRO EXTERIOR SURFACES & FRO BORE OF COUPLER BODY.. INSERT NIPPLE NOSE INTO COUPLER & PUSH FIRLY TO CONNECT. SHAKE TANK SUPPLY HOSE TO ENSURE THAT NIPPLE IS PROPERLY ENGAGED. 6. BE SURE ALL BLEED S ARE CLOSED BEFORE OPENING TANK WITHDRAWAL (Q 26231) SAF4611 PLACARD NON-FLAABLE GAS DIAOND DISCONNECT 1. PUT ON GLOVES AND GOGGLES. 2. CLOSE TANK WITHDRAWAL & TANK SUPPLY HOSE. 3. SLOWLY OPEN BLEED S ON TANK SUPPLY HOSE & COUPLER. 4. DISCONNECT TANK SUPPLY HOSE FRO COUPLING NIPPLE. 2 7
5 SAF08283 ISCELLANEOUS DECALS FLAABLE/NON-FLAABLE PLACARD DECALS 11 (Q 26234) SAF11 CAUTION/FIRST AID (3) Pieces x (Q 26221) SAF07841 PLACARD GASOLINE DIAOND AG-071 EERGENCY FIRST AID SHOULD OR S OF THIS PRODUCT COE IN CONTACT WITH EYES OR SKIN (Q 26222) PLACARD FLAABLE DIAOND 1. FLUSH AFFECTED AREA THOROUGHLY WITH WATER FOR 1 INUTES. 2. REOVE IEDIATELY ANY CONTAINATED CLOTHING. 3. DO NOT APPLY SALVES OR OINTENTS TO BURNS. GET TO DOCTOR AS SOON AS POSSIBLE. CAUTION ANHYDROUS AONIA (Under Pressure) READ CAREFULLY 8283 (Q 26230) SAF08283 PLACARD 1993 DIAOND 1. KEEP AWAY FRO POP-OFF ARKED THIS IS A SAFETY DEVICE AND SHOULD NOT BE TAPERED WITH. 2. STAND UP WIND WHEN WORKING AROUND EQUIPENT. 3. WEAR GOGGLES AND RUBBER GLOVES WHEN TRANSFERRING PRODUCT AND BLEEDING HOSES. 4.DO NOT FILL TANK IN EXCESS OF 8% FULL.. NEVER PLACE ANY PART OF BODY IN LINE WITH OR HOSE OPENINGS. USE EXTREE CARE IN HANDLING HOSES. 6. SLOWLY BLEED HOSES AFTER TRANSFERRING PRODUCT. 7.CLOSE S FIRLY BUT DO NOT WRENCH. 8. DO NOT PERIT CHILDREN NEARTHIS EQUIPENT. 9. PARK EQUIPENT AWAY FRO BUILDINGS OR ANY VISIBLE FIRE HAZARDS. NEVER ALLOW TANKS TO BE SUBJECTED TO EXTREE HEAT DO NOT ATTEPT ANY REPAIRS OF THIS EQUIPENT. IN EVENT OF ANY FAILURE CALL YOUR DEALER IEDIATELY. DO NOT OPERATE THIS EQUIPENT UNTIL YOU HAVE RECEIVED INSTRUCTIONS FRO YOUR DEALER (Q 26220) SAF (Q 26229) SAF0818 PLACARD FLAABLE GAS DIAOND PLACARD PROPANE DIAOND SAF
6 FLAABLE GAS DECALS 7844 FLAABLE GAS 4 LETTERS (Q 26224) ISCELLANEOUS DECALS (Q 26226) 7843 (Q 26223) SAF (Q 26228) SAF (Q 2622) SAF0784 FLAABLE 8 LETTERS PROPANE 2 LETTERS PROPANE 6 LETTERS PROPANE 8 LETTERS 12-A SV TRIANGLE INIU + FIRST AID WATER 9 X 2. INIU WEAR YOUR GOGGLES 6 x 4 INIU AXIU PULLING SPEED (reverse for window) 4 X 3 INIU (Q 2623) SAF12A (Q 26201) SAF (Q 26202) SAF (Q 26203) SAF A G (Q 26227) NO SOKING 2 LETTERS (Q 26247) SAF7131 SAF INHALATION HAZARD 2 Letters Green on White (Q 26217) SAF (Q 262) SAF (Q 26219) SAF INHALATION HAZARD 3 Letters Green on White 4 INHALATION HAZARD Green on White 04 (Q 26232) SAF04 08 FIRST AID UIX A DEEPS GNILLUP.H.P. 2 elbisnopser elcihev gnillup NH3 82% 24 X.2 INIU LIQUEFIED 4 LETTERS RELIEF 3 x (Q 2621) SAF2621 INHALATION HAZARD DECALS FIXED LEVEL GAGE RELIEF HOSE
Installation, Operation & Maintenance Manual for Flo-Max Coupler Bracket Model FM150
Installation, Operation & Maintenance Manual for Flo-Max Coupler Bracket Model FM150 January 2013 Form FVC 084 - Rev 02 IMPORTANT: KEEP THIS DOCUMENT WITH THE PRODUCT UNTIL IT REACHES THE END USER. 1.
More informationInstallation, Operation, Maintenance Manual For Quick-Jaw Models AL363, L364 & AL366
Installation, Operation, Maintenance Manual For Quick-Jaw Models AL363, L364 & AL366 February 2014 Form FVC076 - Rev 07 IMPORTANT: KEEP THIS DOCUMENT WITH THE PRODUCT UNTIL IT REACHES THE END USER. 1.
More informationPRODUCT SERIES: A-SF-3000BD
CONTINENTAL NH3 PRODUCTS INSTALLATION, OPERATION, REPAIR AND MANTINANCE INSTRUCTIONS PRODUCT SERIES: A-SF-3000BD ATTENTION: Please follow all of the instruction in this manual carefully and read the entire
More informationTriPod Safety Coupler Installation & Operating Instructions for Models TP4, TP5, TP6, and TP7
TriPod Safety Coupler Installation & Operating Instructions for Models TP4, TP5, TP6, and TP7 March 2014 Form FVC097 - Rev03 IMPORTANT: KEEP THIS DOCUMENT WITH THE PRODUCT UNTIL IT REACHES THE END USER.
More informationTroubleshooting Lift Cylinder Drift and Tilt Cylinder Drift
Troubleshooting Lift Cylinder Drift and Tilt Cylinder Drift Compact Track Loader: All Multi Terrain Loader: All Skid Steer Loader: All ReferenceTesting and Adjusting, RENR4837, "216, 226, 232, and 242
More informationAssembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &
REDQ Regulators Model 411B Barstock Design Powreactor Dome Regulator OPERATION AND MAINTENANCE Contents Scope..............................1 Installation..........................1 General Description....................1
More informationHydraulic Piston Accumulators
Ride Control Engineering Services PWCE Extendavator Paul Wever Construction Equipment Co., Inc. P.O. Box 85 401 Martin Drive Goodfield, IL 61742-0085 Phone (309) 965-2005 Fax (309) 965-2905 1-800-990-PWCE
More informationOXY FUEL SYSTEM SET UP & SHUT DOWN PROCEDURE CHECKLIST ACETYLENE FUEL GAS
OXY FUEL SYSTEM SET UP & SHUT DOWN PROCEDURE CHECKLIST ACETYLENE FUEL GAS Items needed for demonstrations: Fire extinguisher PPE (Personal Protective Equipment): o Lab coats/welding jackets o Leather gloves
More informationMODEL 840 AIR HYDRAULIC PUMP INSTRUCTION
MODEL 840 AIR HYDRAULIC PUMP INSTRUCTION Jackco Transnational Inc. 202 South El Monte, CA 888-452-2526 www.jackco.com FOR YOUR SAFETY Read all instructions, warnings and cautions carefully. Follow all
More informationHot Compressed Air Lance Operation Manual. LAB Manufacturing 9483 Reading Road Cincinnati, OH (800)
Hot Compressed Air Lance Operation Manual www.heatlances.com LAB Manufacturing 9483 Reading Road Cincinnati, OH 45215 (800) 776-5830 PARTS CHECK LIST NOTE: Check all fittings & connections prior to operation.
More informationHYDRAULIC WINCH FOR AUGERS UP TO WR10 X 71 / W130 X 41 ASSEMBLY & OPERATION MANUAL
HYDRAULIC WINCH ASSEMBLY & OPERATION MANUAL Read this manual before using product. Failure to follow instructions and safety precautions can result in serious injury, death, or property damage. Keep manual
More informationSafe Work Instructions For Oxygen Acetylene Equipment
Safe Work Instructions For Oxygen Acetylene Equipment Policy Sponsor: Assistant Vice President Facilities Management Responsible Unit: Trade Services Approval Date: September 2010 Revisions: January 2018
More informationEMERGENCY RESPONDER INFORMATION
EMERGENCY RESPONDER INFORMATION Ammonia is a Toxic Gas When released can come out as liquid and as a vapor cloud at the same time. Vapor cloud can be heavier than air Vapor cloud can be white or invisible
More informationUser Instruction Manual
User Instruction Manual 4500 psi Air Compressor Ver 2, 1.18 Contents Parts Included...3 Assembly Instructions...3-5 Operation Instructions...6-7 Oil Change Intervals...8 Air Filter Replacement...9 Setting
More informationInstruction sheet for Hydraulic Cylinder
Oper at or smanual 1088710891 Hydr aul i ccyl i nder s Instruction sheet for Hydraulic Cylinder NOTE PLEASE READ AND FOLLOW THIS INSTRUCTION BEFORE YOU USE Yellow Jackit CYLINDERS. Carefully inspect all
More informationROUGHNECK II Pumpless Drain
SERVICE BULLETIN SB4027 Rev. K 08/18 For Used Oil Only ROUGHNECK II Pumpless Drain Model #4110-022 FOR USED OIL ONLY (Black) For Antifreeze Only Model #4110-023 FOR USED ANTIFREEZE ONLY (Green) Patent
More informationAIR STAPLER MODEL: CSG1C Part No
AIR STAPLER MODEL: CSG1C Part No. 3110375 0506 OPERATING & MAINTENANCE INSTRUCTIONS SPECIFICATIONS Min. Hose Size (ID)... 6mm (1/4 ) Air Inlet Connector... 10mm Quick Fit Ave. Air Consumption... 0.27 cfm
More informationAnhydrous Ammonia: Safety and the Farmer
Anhydrous Ammonia: Safety and the Farmer 2016 1 Anhydrous Ammonia: Safety and the Farmer Version 2.0 Information booklet regarding the safe handling and transporting of anhydrous ammonia under the Transportation
More informationLARGE DRY CHEMICAL, TWIN-AGENT, AFFF, HALON 1211, AND AQUASONIC (NITROGEN-OPERATED SYSTEMS) Pressure Regulator Test Manual
LARGE DRY CHEMICAL, TWIN-AGENT, AFFF, HALON 1211, AND AQUASONIC (NITROGEN-OPERATED SYSTEMS) Pressure Regulator Test Manual 002694 IntroductIon 8-1-11 Page 1 ForEWord This manual is intended for use with
More informationaccidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS
18 GAUGE 1-1/4 INCH BRAD NAILER Model: 7611 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement, or other masonry.
More informationTraining Program 1A Filling 1 lb. Refillable Propane Cylinders
Training Program 1A Filling 1 lb. Refillable Propane Cylinders WARNING: MAKE SURE TO CHECK LOCAL AND STATE LAWS FOR TRAINING AND LICENSING REQUIREMENTS BEFORE FILLING THE 1 LB REFILLABLE CYLINDER 1.0 About
More informationREV0709. Parts List. Hydraulic Cylinder Model MODEL C SINGLE-ACTING, SPRING RETURN HYDRAULIC CYLINDER. Max. Capacity: 55.2 Tons at 10,000 PSI
REV0709 Parts List Hydraulic Cylinder Model 10312 MODEL C SINGLE-ACTING, SPRING RETURN HYDRAULIC CYLINDER Max. Capacity: 55.2 Tons at 10,000 PSI REV0709 Item No. Part No. No. Req d Description 1 10606
More informationLITTLE MAX MODEL 50G 50,000 BTU PROPANE TORCH
LITTLE MAX MODEL 50G 50,000 BTU PROPANE TORCH INSTRUCTION MANUAL MODEL 50G PROPANE TORCH ASSEMBLY, TESTING, AND OPERATING INSTRUCTIONS PLEASE READ AND RETAIN THIS INFORMATION FOR FUTURE REFERENCE DO NOT
More informationAIR STAPLER. MODEL: CSG3KC Part No OPERATING & MAINTENANCE INSTRUCTIONS
AIR STAPLER MODEL: CSG3KC Part No. 3110380 0506 OPERATING & MAINTENANCE INSTRUCTIONS SPECIFICATIONS Min. Hose Size (ID)... 6mm (1/4 ) Air Inlet Connector... 10mm Quick Fit Ave. Air Consumption... 0.4 cfm
More informationTable of Contents. Operating Instructions. Resource v.2 Conserving Regulator
Operating Instructions Table of Contents Resource v.2 Conserving Regulator Safety Information Device Precautions Introduction Product Features Product Specifications Feature Illustrations Set Up Usage
More informationSCUBAPRO. Balanced Power Inflator
SCUBAPRO Balanced Power Inflator USE THIS GUIDE AS A REFERENCE WHEN SERVICING THE BALANCED POWER INFLATOR Important note: The following information is not designed to be a complete training guide for servicing
More informationaccidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS
18 GAUGE 2 INCH BRAD NAILER Model: 7555 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement, or other masonry.
More informationPDY TON HYDRAULIC CRIMPING TOOL WARNING
OPERATORS ORS GUIDE PDY-1220 12 TON HYDRAULIC CRIMPING TOOL All information found in this guide must be read and understood before use or testing of this tool. Failure to read and understand these warnings
More informationFlexfence Swaging Unit. Product Manual. Release 02/16.
Product Manual www.ingalcivil.com.au 1.0 Safety Precautions 1.1 Personal Protection While operating this equipment it is recommended that the following personal protective equipment be worn; Long sleeve
More informationASSEMBLY & OPERATIONS MANUAL. Straight & Clean Torch Cuts. Every Time.
ASSEMBLY & OPERATIONS MANUAL Straight & Clean Torch Cuts. Every Time. CAUTION ALWAYS USE FLASH BACK ARRESTORS (purchased separately) READ THIS BOOK THOROUGHLY AND FOLLOW INSTRUCTIONS! FAILURE TO USE OSHA
More informationI NSTALLATION INSTRUCTIONS F OR T HE A-53-RSS, A-72-R SS A ND THE A-98-R SS ANHYDROUS AMMONIA R ISER SAFETY SHEAR UNITS 130 YORKTOWN, DALLAS TX
I NSTALLATION INSTRUCTIONS F OR T HE A-53-RSS, A-72-R SS A ND THE A-98-R SS ANHYDROUS AMMONIA R ISER SAFETY SHEAR UNITS 130 YORKTOWN, DALLAS TX 75208 800-537-5642 FAX 214-761-9519 T O ENSURE PROPER FUNCTIONALITY
More informationCS150 CAP STAPLER OWNER S MANUAL
Operation Revised 6/2013 www.stingerworld.com CS150 CAP STAPLER OWNER S MANUAL! Maintenance Safety Warranty PLEASE READ! This manual contains important information about product safety. WELCOME TO STINGER
More information24L AIR COMPRESSOR MODEL NO: TIGER 11/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13
24L AIR COMPRESSOR MODEL NO: TIGER 11/250 PART NO: 2244010 OPERATION & MAINTENANCE INSTRUCTIONS LS01/13 INTRODUCTION Thank you for purchasing this product. Before attempting to use this product, please
More information24L AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: RANGER 7/240 PART NO: LS0913
24L AIR COMPRESSOR MODEL NO: RANGER 7/240 PART NO: 2242000 OPERATION & MAINTENANCE INSTRUCTIONS LS0913 INTRODUCTION Thank you for purchasing this CLARKE 24L Air Compressor. Please read this manual fully
More informationREL-510H WARNING NOTICE 12 TON SINGLE ACTING REMOTE HYDRAULIC CRIMPING HEAD
OPERATORS ORS GUIDE REL-510H 12 TON SINGLE ACTING REMOTE HYDRAULIC CRIMPING HEAD Compatible with U style and RELIABLE R12 shell type 12 ton compression dies. RELIABLE EQUIPMENT & SERVICE CO., INC. 92 Steamwhistle
More informationMMR Air Mask With. with Quick-Connect Hose
MMR Air Mask With with Quick-Connect Hose Upgrade Kits P/N 10025120 Slide to Connect P/N 10050038 Slide to Connect w/ Solid Cover P/N 10038666 Push To Connect P/N 10050037 Push To Connect w/ Solid Cover
More informationKJ4000 Operating Instructions & Parts Manual NSN
KJ4000 Operating Instructions & Parts Manual NSN 1025-01-473-7710 Mandus Group Ltd. KJ4000 Operators Manual Date: 3 Jan. 2002 TABLE OF CONTENTS General Safety Instructions...Page 1 Operator Instructions...Page
More information35 TON HYDRAULIC PUNCH WARNING
OPERATORS GUIDE REL-35T-PNC 35 TON HYDRAULIC PUNCH NOTICE Sizes, weights and tool specifications listed in this manual are subject to change without notice. Please consult factory for information and updates.
More information100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13
100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: 2244025 OPERATION & MAINTENANCE INSTRUCTIONS LS01/13 INTRODUCTION Thank you for purchasing this product. Before attempting to use this product, please
More informationU.S. CONCRETE, INC. SAFETY POLICY and PROCEDURE MANUAL
SAFE -14 Page 1 of 8 U.S. CONCRETE, INC. SAFETY POLICY and PROCEDURE MANUAL FUNCTION Safety TOPIC Hotwork Permit Program OBJECTIVE(S): GENERAL POLICY: To provide a work atmosphere that is conducive to
More informationInstallation of Your SprayMaster System
Installation of Your SprayMaster System 1. At the installation site, remove all equipment from the corrugated box and the polyethylene drum and replace the drum lid. Check the picture to identify each
More informationstormrider Instructions for Use Version 08/2017
stormrider EN Instructions for Use Version 08/2017 INTRODUCTION DESCRIPTION SAFETY INSTRUCTIONS TECHNICAL DATA HANDLING & OPERATION CARE & MAINTENANCE TROUBLESHOOTING DESCRIPTION Front Sight Barrel Rear
More informationHotspotter. Model WB-100 Professional Series. Assembly, Testing & Operating Instructions. Safety Information:
Hotspotter Model WB-100 Professional Series Assembly, Testing & Safety Information: Safety publications related to safe practice and use: CSA 2-94 U.S. Requirements for Hand-Held LP Torches for use with
More informationDBML-60/80 Squeeze Tool
DBML-60/80 Squeeze Tool OPERATORS MANUAL Description The Mustang Model DBML-60/80 Hydraulic squeeze tool has been manufactured since 1995. A Mustang 3 3/4 bore doubleacting cylinder producing 41,000 lbs
More informationInstallation and Service Manual
An Actuant Company Installation and Service Manual Heavy Duty Hydraulic Stabilization Legs CONTENTS Part # 3010003129 REV 0D Section Page 1.0 Receiving Instructions 2 2.0 Safety Issues 2 3.0 Hydraulic
More informationTech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) MODEL D INFLATABLE JACKS
SPX Corporation 5885 11th Street Rockford, IL 6119-3699 USA Internet Address: http://www.powerteam.com Tech. Services: (8) 477-8326 Fax: (8) 765-8326 Order Entry: (8) 541-1418 Fax: (8) 288-731 Parts List
More informationSSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR
S S F U SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR MACHINERY DIVISION OWNER S MANUAL UNIT INSTRUCTIONS Please follow all SSFU Safety Instructions. Contact your Duro Dyne Tech Service if you have
More informationCOMPRESSOR REPLACEMENT PROCEDURE (R-134A)
372 ROUTE 4 BARRINGTON, NH 03825 USA TEL (603) 868-5720 FAX (603) 868-1040 1-800-435-6708 COMPRESSOR REPLACEMENT PROCEDURE (R-134A) [ ] If possible operate the compressor with proper charge for 5 minutes
More informationC6Hi (g) 6 H2O + 6 C02(g) + energy
Experient Cell Respiration 110 Cell respiration refers to the process of converting the cheical energy of organic olecules into a for iediately usable by organiss. Glucose ay be oxidized copletely if sufficient
More informationWARNING. RELIABLE EQUIPMENT & SERVICE CO., INC. 301 Ivyland Road Warminster, PA USA Phone: Fax:
OPERATOR'S GUIDE Pivot style control valves may be operated with one hand, leaving the second hand free to control the head. Lever locks in the forward position for tool advance, and in the rear position
More informationINSTALLATION and OPERATION INSTRUCTIONS
INSTALLATION and OPERATION INSTRUCTIONS FLOJET Beer Pump Panels MODEL NO. 66134-1 66134-2 66134-3 66134-4 IMPORTANT INFORMATION This manual has been prepared to assist you in the operation of Perlick Beer
More informationSafety and operating instructions
Safety and operating instructions Oil flow dividers 5, 8 www.cp.com 2 Contents Contents Introduction....................................................................... 5 About the Safety and operating
More informationOPERATION MANUAL Please read this Operation Manual carefully before use, and file for future reference.
English Lubrication Free Air Turbine Handpiece with Water Spray OPERATION MANUAL Please read this Operation Manual carefully before use, and file for future reference. OM-T0286E 001 Thank you for purchasing
More informationAQUARIUS. Operating Instructions for the. Type 70 Electrolytic Gas Soldering / Welding Unit. Table of Contents
AQUARIUS Operating Instructions for the Type 70 Electrolytic Gas Soldering / Welding Unit Table of Contents 1. Important General Remarks 2 2. Safety Instructions 2 3. Description of the Soldering Unit
More informationFor use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum WARNING: FOR OUTDOOR USE ONLY
For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum : FOR OUTDOOR USE ONLY Small Tank LP Kit (STLPK) Installation & Operation Instructions Installation We suggest
More informationYoke Block Instruction Manual
Yoke Block Instruction Manual ! WARNING IMPORTANT: READ MANUAL COMPLETELY BEFORE OPERATING THIS DEVICE This manual contains instructions on periodically required checks to be performed by the user. These
More informationAWG Fittings LLC. Pressure Relief Valve Up to 250 PSI. Product Number Read this instruction manual before use.
AWG Fittings LLC Pressure Relief Valve Up to 250 PSI Product Number 30004033 Read this instruction manual before use. Using this device without t understanding di this products operation and care may lead
More informationACME Connectors and Fittings Extended Type Hose Couplings for Vapor and Liquid Service A7571 and A7575 Series
M onnectors and Fittings xtended Type Hose ouplings for Vapor and Liquid Service 7571 and 7575 Series esigned especially for liquid filling and vapor equalization of LP-Gas and anhydrous ammonia. The limited
More informationRARS5000 AIR BODY SAW OWNER S OPERATING MANUAL
RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL DESCRIPTION 1. No mar 2. No mar tip 3. Housing grip 4. Trigger 5. Air inlet 6. Air inlet plug 7. Plastic board Important! It is essential that you read the
More informationTube-Line Accelerator Spinner Kit
Tube-Line Accelerator Spinner Kit Operator's Manual PP-00799 (19/09/11) 2 TO THE OWNER This manual contains information concerning the adjustment, assembly and maintenance of your Tube-Line Spinner Kit.
More informationSCUBAPRO Repair Guide. S600-S550 Second Stages
SCUBAPRO Repair Guide S600-S550 Second Stages S600 Configuration A S600 Configuration B USE THIS GUIDE AS A REFERENCE WHEN SERVICING THE S600 AND S550 SECOND STAGES S550 P/N 41-047-000 FOR REPAIR OF S600-S550
More informationRegO Adapters, Connector, & Fittings
RegO dapters, onnector, & Fittings Extended Type ouplings for Vapor and Liquid Service esigned especially for liquid filling and vapor equalization of LP-Gas and anhydrous ammonia. The limited travel of
More information5.0 INSPECTING, FILLING AND LABELING SMALL CYLINDERS
5.0 INSPECTING, FILLING AND LABELING SMALL CYLINDERS 23 24 5.0 INSPECTING, FILLING AND LABELING SMALL CYLINDERS INSPECTING, FILLING AND LABELING SMALL CYLINDERS Pre-fill Visual Check Safely inspecting
More informationFisherPak Instructions
FisherPak Instructions Installation and Start-Up Procedures 2 FisherPak Dip Tape Level Gauge Operating Instructions 3 Trouble Shooting Guide 3 FisherPak Disconnection Procedure 4 Rupture Disk Replacement
More information5 Gallon Pressure Pot with HVLP Spray Gun and Hose
California Air Tools 5 Gallon Pressure Pot with HVLP Spray Gun and Hose Model No. 365 Technical Data Type of feed.pressure Maximum pressure in the tank... 0,413Mpa (60PSI) Working pressure in the tank.0,
More information24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS10/13
24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: 2244030 OPERATION & MAINTENANCE INSTRUCTIONS LS10/13 INTRODUCTION Thank you for purchasing this product. Before attempting to use this product,
More informationPoppetted Coaxial Drop Tube Assembly for use with Auto Limiter II. Installation Instructions
Poppetted Coaxial Drop Tube Assembly for use with Auto Limiter II Installation Instructions Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Tel: +1 608 838 8786 800 225 9787 Fax: +1 608 838
More information24 Litre Air Compressor
Operator s Manual 24 Litre Air Compressor WARNING! Before using this appliance, read the Operator s manual and follow all its safety rules and instructions. SPECIFICATION Model Power ITEM DATA HWKAC2 1Kw/1.5HP&1.5Kw/2HP&1.8Kw/2.5HP
More informationGas Conversion Kits Push Through (Positive Pressure) Tube Heater Models
DESCRIPTION These kits are designed to convert from one gas type to another (eg. from NATURAL to PROPANE or from PROPANE to NATURAL) when equipped with White-Rodgers DSI gas valves number 36J23 or 36J58.
More informationSpot Weld Drill Spot Weld Removal System Instruction Manual
85-1001 Spot Weld Drill Spot Weld Removal System Instruction Manual Version 1.1 TABLE OF CONTENTS COMPONENT CHECKLIST 2 GENERAL SAFETY - READ BEFORE USING 3 INSTALL AND STORAGE MAINTENANCE INSTRUCTION
More informationSPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.
2 GALLON TWIN STACK AIR COMPRESSOR Model: 9526 DO NOT RETURN TO STORE. Please CALL 800-348-5004 for parts and service. CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or
More informationPETERSEN 161-SERIES HIGH PRESSURE LIFTING AIR BAGS OPERATING INSTRUCTIONS WARNING!
PETERSEN 161-SERIES HIGH PRESSURE LIFTING AIR BAGS OPERATING INSTRUCTIONS WARNING! Read and understand instructions before using Petersen Plugs. Failure to comply may result in property damage, serious
More informationAIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST
AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST OIL-LESS TYPE IMPORTANT: PLEASE READ CAREFULLY BEFORE STARTING OPERATIONS. THE CONTENTS ARE FOR GENERAL INFORMATION OF ALL THE SIMILAR MODELS. Record
More informationEC Using Agricultural Anhydrous Ammonia Safely
University of Nebraska - Lincoln DigitalCommons@University of Nebraska - Lincoln Historical Materials from University of Nebraska- Lincoln Extension Extension 1994 EC94-738 Using Agricultural Anhydrous
More informationHOT SHOT OPERATING INSTRUCTIONS AND OWNER S MANUAL. Model SPC-500. (Propane Torch)
OPERATING INSTRUCTIONS AND OWNER S MANUAL Model # SPC-500 READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instructions in a safe place for future reference. Do not allow anyone who
More informationOPERATING INSTRUCTIONS AND OWNER S MANUAL READ AND FOLLOW ALL INSTRUCTIONS
READ INSTRUCTIONS CAREFULLY: OPERATING INSTRUCTIONS AND OWNER S MANUAL Model # MH500LPT MH400PT READ AND FOLLOW ALL INSTRUCTIONS Place instructions in a safe place for future reference. Do not allow anyone
More informationHPB25 Hydraulic Paving Breaker
INSTRUCTION MANUAL HPB25 Hydraulic Paving Breaker Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Register this product at www.greenlee.com
More informationCS150 CAP STAPLER OWNER S MANUAL Operation Safety Maintenance Warranty! www.stingerworld.com PLEASE READ! This manual contains important information about product safety. REV 06/15 WELCOME TO STINGER Congratula*ons
More informationCOMBINATION AIR RELEASE DEGASSING (CARD) VALVES INSTALLATION AND MAINTENANCE MANUAL
COMBINATION AIR RELEASE DEGASSING (CARD) VALVES INSTALLATION AND MAINTENANCE MANUAL SPECIFICATIONS: The CARD series air valves are available in 3 pipe sizes, 1, 2 and 4 NPT or socket. Maximum inlet pressure
More information3 Scotch-Weld Polyurethane Reactive Adhesive Applicator Replacement Part Installation Guide
3 Scotch-Weld Polyurethane Reactive Adhesive Applicator Replacement Part Installation Guide Description: AIR SUPPLY LINE KIT Product ID/Stock No.: 62-9895-0005-3 For use with: 3M Scotch-Weld Polyurethane
More informationNeedle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2
Serial No. H-V024-E-7 Needle valve User s Manual Contents (1) Be sure to read the following warranty clauses of our product 1 (2) General operating instructions 2 (3) General instructions for transportation,
More informationHYDRAULIC INTENSIFIER Max. Pressure: See Intensifier Data Plate Weight: 16 Lbs. (7.26 kg)
Form No. 102897 Operating Instructions for: HB443 HB444 HYDRAULIC INTENSIFIER Max. Pressure: See Intensifier Data Plate Weight: 16 Lbs. (7.26 kg) Definition: A devise that raises the inlet pressure to
More informationOPERATORS GUIDE REL-SP SERIES NOTICE WARNING HYDRAULIC SUBMERSIBLE PUMP
OPERATORS GUIDE REL-SP SERIES HYDRAULIC SUBMERSIBLE PUMP SHOWN WITH QUICK DISCONNECT COUPLING SET The REL-SP SERIES Submersible Pumps are a light weight, efficient way to move large quantities of liquids
More information2 in. 18 Gauge Brad Nailer. User manual
8504342 2 in. 18 Gauge Brad Nailer User manual Technical Data Capacity....100pcs Nail length... 15-50mm( 5/8-2 ) Fastener size....18gauge (1.25 1.00mm) Operation pressure 70-110PSI(4.8-7.5bar) Air inlet....1/4
More informationFOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM
IMI CORNELIUS INC One Cornelius Place Anoka, MN 55303-623 Telephone (800) 238-3600 Facsimile (612) 22-326 INSTALLATION INSTRUCTIONS FOR INSTALLING CO 2 BLENDER KIT (P/N 111612000 IN BEER SYSTEM SECONDARY
More informationTentec. Instruction Document. Mini Air Driven Pump Unit Model: HTT.627X Series. Part Identifier
Tentec Page 1 w w w. t e n t e c. n e t Instruction Document Mini Air Driven Pump Unit Model: HTT.627X Series HTT.6271 Maximum Working Pressure = 1500bar (21750 psi) HTT.6272 Maximum Working Pressure =
More informationOperators Manual. Supera Wall Mount Anesthesia Machines. Models: M2300 M2500. (All shown with optional equipment) M2300 M2500
Operators Manual Supera Wall Mount Anesthesia Machines Models: M2300 M2500 (All shown with optional equipment) M2300 M2500 Examination and Preparation for Use Thank you for ordering an Supera Anesthesia
More informationLIQUID OXYGEN. General. Health Effects. Safety Considerations
LIQUID OXYGEN General Oxygen is the second largest component of the atmosphere, comprising 20.8% by volume. Liquid oxygen is pale blue and extremely cold. Although nonflammable, oxygen is a strong oxidizer.
More informationOXYGEN ACETYLENE WELDING & CUTTING EQUIPMENT
OXYGEN ACETYLENE WELDING & CUTTING EQUIPMENT Introduction: The oxy-acetylene torch can be used for various tasks. It can be used for cutting steel, welding steel, brazing and for heating metal. The oxy-acetylene
More informationSafe Handling - Dimethylamine
Safe Handling - Dimethylamine 1. Product Description Physical Properties: Dimethylamine is a colorless, flammable liquefied gas with a characteristic fishy or ammonia type odor Chemical Formula (CH 3)2
More informationProduct Information News September 26, 2003
Product Information News September 26, 2003 LEVER HEIGHT INSPECTION FOR FIREHAWK MMR MSA is announcing a revision to the instructions for the Firehawk MMR Second Stage Regulator as they relate to the air
More informationAnhydrous Ammonia: Safety and the Farmer
Anhydrous Ammonia: Safety and the Farmer 2019 Anhydrous Ammonia: Safety and the Farmer 2019 Information booklet regarding the safe handling and transporting of anhydrous ammonia under the Transportation
More informationExtendAire TM II. Intermediate Pressure Accessory Kit USER INSTRUCTIONS
ExtendAire TM II Intermediate Pressure Accessory Kit USER INSTRUCTIONS THIS MANUAL MUST BE CAREFULLY READ AND FOLLOWED BY ALL PERSONS WHO HAVE OR WILL HAVE THE RESPONSIBILITY FOR USING OR SERVICING THIS
More informationINSTALLATION INSTRUCTIONS
EDGEMERE CENTERSET LAVATORY FAUCET INSTALLATION INSTRUCTIONS 708.0 Thank you for selecting American Standard... the benchmark of fine quality for over 00 years. To ensure that your installation proceeds
More information3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289
3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS Item #31289 The EASTWOOD 3 GALLON, OILLESS PANCAKE COMPRESSOR, with an Integral Air Regulator, efficiently supplies all compressed air requirements for
More informationWinter Shut Down Procedure
Winter Shut Down Procedure Although we live in Beautiful BC, we still experience freezing temperatures. To minimize the risk of freeze damage to your irrigation system, you ll need to winterize it. Our
More informationMODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR
MODEL NUMBER: 45043-450P-A AUTOMATIC PORTABLE COMPRESSOR IMPORTANT: It is essential that you and any other operator of the product read and understand the contents of this manual before installing and
More informationOperating Instructions Models and Hydrostatic Test Pumps
Operating Instructions Models 46501 and 465010 Hydrostatic Test Pumps 46501 DIMENSIONS: WEIGHT: PUMP: ENGINE: CONTROL: GAUGE: DISCHARGE HOSE: INLET HOSE: 28 (70cm) L x 24 (60cm) W x 35 (87.5cm) H 136 lbs.
More informationOxy-Fuel Safety Training. Participant s Guide
Oxy-Fuel Safety Training Page 1 of 19 Contents What s Included?... 3 Oxy-Fuel Safety Training Objectives... 4 Chapter 1: Safety & Responsibility... 6 Chapter 2: Gases in the Work Area... 7 Chapter 3: Equipment
More informationAIR LIFTINGBAG OPERATIONGUIDE. BasicSafelVPrecautions Equipment Description OperatingInstructions - Applications.
PARATECH@ AIR LIFTINGBAG OPERATIONGUIDE " BasicSafelVPrecautions Equipment Description OperatingInstructions - Applications. General,Cleaning& Inspection - - - - - -- Basic Safety Precautions 1. Regardless
More information