Roxar 2 System Mechanical Retrieval Tool
|
|
- Estella Patterson
- 6 years ago
- Views:
Transcription
1 FA-T226-A Product Data Sheet Roxar 2 System Mechanical Retrieval Tool The Roxar 2 Mechanical Retrieval Tool is a high quality tool for installation and retrieval of probes and coupons in standard 2 mechanical access systems under full operational pressure. The tool is compatible with access systems provided by most common vendors on the market. The tool works on a telescopic principle, comprising a fixed inner barrel and an outer barrel that moves during operation. Probes/ coupon holders are installed or retrieved by pulling or pushing the outer barrel, assuming a balanced pressure within the tool. Roxar 2 Mechanical Retrieval Tool comes as a kit including retrieval tool (complete with pressure gauge and bleed valve), back pressure pump, and spare parts - in a convenient transport case. From a safety perspective, Roxar 2 Mechanical Retrieval Tool is designed for use with a double block and bleed valve, to ensure double pressure barriers for the valve 1) Roxar Service valve is described in separate data sheet. Safety Notes: Operating any telescope type mechanical retrieval tool is a potentially safety critical operation. If pressure is not balanced within the mechanical retrieval tool under operation, the pressure difference may push the outer barrel with uncontrolled force and speed, and in consequence, hit and injure personnel and equipment. It is therefore required that a Back Pressure Pump is always used with Roxar 2 Mechanical Retrieval Tool when operating on pressurized lines or vessels 2). High pressure retrieval tools must only be operated by trained personnel and according to controlled operating procedures. 1) Single service valves also available ask vendor for advice. 2) Observe that Roxar recommend Hydraulic Access and Retrieval Tool system as a safer (no external moving parts) and more convenient (less operational space required) alternative. Mechanical system may be converted to hydraulic system - see separate data sheet. 1
2 Mechanical Retrieval Tool Dimensional Data Back pressure pump for Mechanical Retrieval Tool A back pressure pump shall always be used to raise the pressure inside the retrieval tool to be slightly higher than the pipe pressure. This will ensure that the outer barrel of the tool will not accidentally move uncontrolled during probe/coupon removal. Back pressure pump for Mechanical Retrieval Tool with service valve and transport case with Double Block and Bleed Service Valve. For device length definition, ask vendor for advice. Maximum Device Length (mm/ ) 150/6 240/ / / / /46 Mechanical Retrieval Tool length, retracted, incl. service valve (mm/ ) 894/ / / / / /75.4 Mechanical Retrieval Tool length, extended, incl. service valve (mm/ ) 1328/ / / / / /132.6 Mech. Retrieval Tool weight (kg) excl. service valve Ordering Information can be purchased a complete kit (including accessories and service valve) or as a retrieval tool only. Dimensional illustrations are shown in pages 6-7 of the data sheet. Please refer to data Sheet for Roxar Service Valve for service valves. 2 3
3 Model Selector - Model Selector - Pump for Mechanical Retrieval Tool Model Product Description MRT Mechanical Retrieval Tool Pressure Rating 1 Max 6,000 psi Design Pressure Tool Length L01 Maximum device Length:150 mm L02 Maximum device Length: 240 mm L03 Maximum device Length: 425 mm L04 Maximum device Length: 640 mm L05 Maximum device Length: 920 mm L06 Maximum device Length: 1170 mm Tool Material (Main Components) 2G6A Alloy 17-4PH (UNS S17400) Cylinder, ASTM A182 F22 Hammer Nut EN NACE MR0175 9X9X 1 Project Specific Material Operating mode and conditions 01 Standard Viton O-rings 02 Rapid Gas Decompression FR 25/90 O-rings 03 Rapid Gas Decompression and/or 100 % Methanol Elast-O-Lion 101 O-rings Approvals Model PUMP-RT M3 M Product Description Pump for Retrieval Tool System Pump Application and Operation Manual (back filling only) for MRT Approvals ROXAR Standard (no 3rd party approval) Z 1 Pump ATEX - Equipment Category 2 (Zone 1) ZZ TG XX 1 Z X TX 1 Tag Plates No Tag Plates Standard Tag Plates Project Specific Tag Plates Factory Options Standard product ETO product 1 Not Available with factory Option Z Certificate, Tests, Calibrations and Services (Not Required, all are optional) Special Tests and Certificates Other Testing Project specific testing M N 1 ZZ TG XX 1 Z X ROXAR Standard (no 3rd party approval) PED Compliant Tool Tag Plates No Tag Plates Standard Tag Plates Project Specific Tag Plates Factory Options Standard product ETO product Certificate, Tests, Calibrations and Services (Not Required, all are optional) Other Testing TX 1 Project-specific testing 1 Not Available with factory Option Z 4 5
4 Mechanical Retrieval Tool Dimensional Data Table continued from previous page Probe Measurement Probe Measurement 150 mm 640 mm 240 mm 920 mm 425 mm 1170 mm 6 7
5 Head Office Roxar products: Emerson Roxar Flow Measurement AS Tel: CIS Tel: Europe Tel: North America Tel: Middle East Tel: Asia Pacific Tel: Australia Tel: Latin America Tel: Emerson. All rights reserved. The Emerson logo is a trademark and service mark of Emerson Electric Co. Brand name is a mark of one of the Emerson Automation Solutions family of business units. All other marks are the property of their respective owners. The contents of this publication are presented for information purposes only, and while effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice. The Roxar products are protected by patents. See for details. 8
Roxar 2 System Mechanical Retrieval Tool
Roxar Mechanical Retrieval Tool FA-T226-A Product Data Sheet 03.02.2016 Roxar 2 System Mechanical Retrieval Tool The Roxar 2 Mechanical Retrieval Tool is a high quality tool for installation and retrieval
More information1805 Series Relief Valves
Instruction Manual Form 1211 1805 Series October 2011 1805 Series Relief Valves! WARNING Failure to follow these instructions or to properly install and maintain this equipment could result in an explosion
More information1305 Series Pressure Reducing Regulators
Instruction Manual Form 1095 1305 Series October 2009 1305 Series Pressure Reducing Regulators! Warning Fisher regulators must be installed, operated, and maintained in accordance with federal, state,
More information1805 Series Relief Valves
October 2011 1805 Series Relief Valves P1026 1805G Type 1805-2 Type 1805-4 Figure 1. Typical 1805 Relief Valves Introduction The 1805 Series relief valves are designed for use in farm tap applications
More information64 Series Pressure Reducing Regulators
Instruction Manual Form 1245 64 Series March 2006 64 Series Pressure Reducing Regulators W1943 Figure 1. 64 Series Regulator Introduction Scope of Manual This manual provides instructions for the installation,
More informationDamcos PHP Portable hand pump unit 5 l. Product Data Sheet September 2014 SD E04
Damcos PHP 25-05 Portable hand pump unit 5 l Product Data Sheet September 2014 SD 6601-2E04 TM Damcos PHP 25-05 September 2014 General description Double-acting portable hand pump incl. 5 l. reservoir
More information299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012
Installation Guide English September 2012 299H Series Introduction This Installation Guide provides instructions for installation, startup, and adjustment of 299H Series regulators. To receive a copy of
More informationType 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator
January 2009 Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator Introduction The Type 310A pilot-operated high-pressure regulator (Figure 1) is used where high capacity
More informationTESCOM 50-4X Series Safety, Installation & Start-Up Procedures
Operations & Service Manual TESCOM 50-4X Series Safety, Installation & Start-Up Procedures Do not attempt to select, install, use or maintain this product until you have read and fully understood this
More informationType 1367 High-Pressure Instrument Supply System with Overpressure Protection
Instruction Manual D100343X012 Type 1367 November 2017 Type 1367 High-Pressure Instrument Supply System with Overpressure Protection TYPE 252 FILTER 2ND-STAGE TYPE 67CF FILTER-STYLE REGULATOR INLET TYPE
More informationType EZH Relief or Backpressure Regulator
Bulletin 71.4 D103574X012 Type EZH December 2017 Type EZH Relief or Backpressure Regulator P1668 Figure 1. Type EZH Relief Valve or Backpressure Regulator Features Bubble Tight Shutoff A knife-edged metal
More informationProduct Data Sheet L-TRDD-D Rev. 1 November Shafer L-Series Linear Valve Actuators Thrust Ratings and Dimensional Data
Product Data Sheet L-TRDD-D-11097 Rev. 1 November 2017 Shafer L-Series Linear Valve Actuators Thrust Ratings and Dimensional Data Product Data Sheet L-TRDD-D-11097 Rev. 1 Shafer L-Series November 2017
More informationT208VR Series Tank Blanketing Vacuum Regulator
February 2014 T208VR Series Tank Blanketing Vacuum Regulator Figure 1. Typical T208VR Series Vacuum Regulator Introduction The T208VR Series direct-operated vacuum regulators are used where a decrease
More informationCOSASCO 3600 PSI SINGLE ISOLATION SERVICE VALVE (FR) MAINTENANCE
COSASCO 3600 PSI SINGLE ISOLATION SERVICE VALVE (FR) MAINTENANCE Rohrback Cosasco Systems, Inc. 11841 E. Smith Avenue Santa Fe Springs, CA 90670 Tel: (562) 949-0123 (800) 635-6898 Fax: (562) 949-3065 www.cosasco.com
More informationFisher L2sj Low Emission Liquid Level Controller
L2sj Controller Product Bulletin Fisher L2sj Low Emission Liquid Level Controller The rugged Fisher L2sj low emission liquid level controller uses a displacer type sensor to detect liquid level. This controller
More informationType R622 Pressure Reducing Regulator
Type R622 Pressure Reducing Regulator June 2010 Compact Design Protective Inlet Screen High Capacity Internal Relief Light Weight W8806 Inlet and Outlet Pressure Gauge Taps Figure 1. Type R622 Pressure
More informationShafer Gas-Hydraulic Tanks Replacing Hydraulic Fluid Procedure on an Existing Actuator
MIS L10: Replacing Hydraulic Fluid Shafer Gas-Hydraulic Tanks Replacing Hydraulic Fluid Procedure on an Existing Actuator www.shafervalve.com The purpose of this procedure is to guide the operation of
More informationR133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid
R133 Brass high pressure regulator, suitable for compressed air, gas and liquid HELYON 5 Chemin du Jubin 6957 DARDILLY Tél. +33 () 7 5 16 7 - Fax +33 () 7 5 16 71 FEATURES High pressure regulator for cylinder
More informationY692VB Series Vacuum Breaker
Y692VB Series Vacuum Breaker Bulletin 71.3:Y692VB June 2009 W7429 Figure 1. Type Y692VB Vacuum Breaker Introduction The Y692VB Series direct-operated vacuum breakers are used for the precise control of
More informationEL-O-Matic E and P Series Pneumatic Actuator SIL Safety Manual
SIL Safety Manual DOC.SILM.EEP.EN Rev. 0 April 2017 EL-O-Matic E and P Series Pneumatic Actuator SIL Safety Manual schaal 1:1 EL Matic TM EL-O-Matic E and P Series DOC.SILM.EEP.EN Rev. 0 Table of Contents
More information1301 Series High-Pressure Regulators
Instruction Manual Form 1111 Types 1301F and 1301G March 2013 1301 Series High-Pressure Regulators! WARNING Failure to follow these instructions or to properly install and maintain this equipment could
More informationQuick Start Guide LIQ-QSG-499ACL-03, Rev I July Rosemount 499ACL-03. Monochloramine Sensor
Quick Start Guide LIQ-QSG-499ACL-03, Rev I July 2017 Rosemount 499ACL-03 Monochloramine Sensor Safety information CAUTION! SENSOR/PROCESS APPLICATION COMPATIBILITY The wetted sensor material may not be
More informationTypes 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators
Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators July 2010 W3716 W3507 Type 1808 Type 1808A Figure 1. Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators
More informationTwo-Wire In Situ Oxygen Analyzer (550 to 1400 C)
Product Data Sheet PDS 106-581.A01 September, 2007 Model 5081FG Two-Wire In Situ Oxygen Analyzer (550 to 1400 C) Intrinsically safe: ATEX, Zone 1, EEx ia IIC T4 Class I, Div. I, Gr. A, B, C, D T4 Operates
More informationMicro Motion 7812 Fiscal Gas Density Meter
Product Data Sheet PS-001162, Rev. B April 2009 Micro Motion 7812 Fiscal Gas Density Meter Micro Motion density and concentration meters are built to tackle the most demanding process and fiscal applications.
More informationFisher Lever Lock Handlever Actuators for POSI SEAL A81 Rotary Valves
Instruction Manual Lever-Lock Handlever Actuator Fisher Lever Lock Handlever Actuators for POSI SEAL A81 Rotary Valves Contents Introduction... 1 Scope of Manual... 1 Description... 1 Specifications...
More informationDANFLO Control Valves 400 Series Model 20
DANFLO Control Valves 400 Series Model 20 Back Pressure/Pressure Relief The DANFLO Model 20 is a pilot operated valve suitable for use in gas or liquid facilities and requires no outside power for operation.
More informationTypes ACE95 and ACE95Sr Tank Blanketing Valves
Types ACE95 and ACE95Sr Tank Blanketing Valves Bulletin 74.1:ACE95 May 2010 W9133 W8155 Figure 1. Type ACE95 Tank Blanketing Valve Figure 2. Type ACE95Sr Tank Blanketing Valve Features Fully Balanced Pilot
More informationRELIEF VALVES. V Series. Process Management TM. Type V/20-2. Type V/50. Type V/60
RELIEF VALVES V Series Type V/2-2 Type V/5 Type V/6 Process Management TM V/5 and V/6 Series Spring-Loaded Relief Valves The spring-loaded relief valves are designed to keep line pressure below preset
More informationTwo-Wire In Situ Oxygen Analyzer (550 to 1400 C)
Product Data Sheet PDS 106-581.A01 March, 2004 Model 5081FG Two-Wire In Situ Oxygen Analyzer (550 to 1400 C) Intrinsically safe: - CENELEC EEx ia IIC - Class I Div. I Gr. B, C, D (pending) Operates at
More informationTypes ACE95 and ACE95Sr Tank Blanketing Valves
August 2013 Types ACE95 and ACE95Sr Tank Blanketing Valves W9133 W8155 Figure 1. Type ACE95 Tank Blanketing Valve Figure 2. Type ACE95Sr Tank Blanketing Valve Features Fully Balanced Pilot Design Reduces
More information61 Series Pilots for Pilot-Operated Pressure Reducing Regulators
61 Series Pilots for Pilot-Operated Pressure Reducing Regulators June 2011 Introduction 61 Series pilots are used with Types 1098-EGR and EZL pressure reducing regulators. These pilots can also be integrally
More informationType ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002
Installation Guide English May 2002 Type ACE97 Introduction This installation guide provides instructions for installation, startup, and adjustment. To receive a copy of the instruction manual, contact
More informationLV LOADER DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE
LV LOADER DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE SPECIFICATIONS: 10 gpm (38 lpm) Nominal Capacity. Rated up to 4000 psi (275 bar). Port Sizes-Inlet/Outlet #8SAE (3/4-16). Work Ports #8SAE
More informationMODEL CALIBRATION GAS DELIVERY SYSTEM
MODEL 1200-26 CALIBRATION GAS DELIVERY SYSTEM Sierra Monitor Corporation 1991 Tarob Court, Milpitas, CA 95035 (408) 262-6611 MODEL 1200-26 CALIBRATION GAS DELIVERY SYSTEM APPLICABILITY & EFFECTIVITY This
More informationType PRX/120, PRX/125, PRX-AP/120, PRX-AP/125, PRX/181, PRX/182, PRX/131 and PRX-AP/131 Pilots
Instruction Manual 0006EN-PRX-IM PRX Series July 2008 - Rev. 00 Type PRX/120, PRX/125, PRX-P/120, PRX-P/125, PRX/1, PRX/2, PRX/131 and PRX-P/131 Pilots summary Introduction... 1 Characteristics... 1 Labelling...
More informationFisher Lever-Lock Handlever Actuators for POSI-SEAL A81 Rotary Valves
Instruction Manual D103319X012 Lever-Lock Handlever Actuator Fisher Lever-Lock Handlever Actuators for POSI-SEAL A81 Rotary Valves Contents Introduction................................. 1 Scope of Manual.........................
More informationAutocalibration Systems for In Situ Oxygen Analyzers
Product Data Sheet PDS 106-340AC.A01 February, 2006 SPS 4001B, IMPS 4000 and MPS 3000 Autocalibration Systems for In Situ Oxygen Analyzers Cost-effective autocalibration systems for installations ranging
More informationSPECIFICATION // DATA SHEET WATER DRAIN VALVE AM SENSORS LTD AMS-S-084/DS/ (ISSUE 1)
SPECIFICATION // DATA SHEET WATER DRAIN VALVE 1 Introduction The Water Drain Valve was developed for a major oil company to detect the presence of fuel when discharging water through the drain line of
More informationUn-Pressurized Orefice Fittings FIO EZ. Parts List and Operation Instructions TECHNICAL MANUAL. Dn 2-6 Class Lbs
Un-Pressurized Orefice Fittings FIO EZ Parts List and Operation Instructions TECHNICAL MANUAL Dn 2-6 Class 150-600 Lbs US US 2 FIO EZ - MT 108-US - 05-2016 FIO EZ Important Instructions US Pietro Fiorentini
More informationType 1190 Low-Pressure Gas Blanketing Regulator
April 202 Type 90 Low-Pressure Gas Blanketing Regulator W7428 Figure. Type 90 Low-Pressure Gas Blanketing Regulator Introduction The Type 90 low-pressure gas blanketing regulator is used for extremely
More informationShafer RV-Series Rotary Vane Valve Actuators
Shafer RV-Series Rotary Vane Valve Actuators Product Data Sheet RV-ASDD-D-3-06-09 Rev. 1 November 2017 U.S. Customary Units Dimension: inches (in) Torque: Inch Pounds (in-lbs) Pressure: Pounds Per Square
More informationModulating liquid level regulators, servo-controlled PMFL / PMFH and SV
MAKING MODERN LIVING POSSIBLE Technical brochure Modulating liquid level regulators, servo-controlled / PMFH and SV For modulating liquid level control in refrigeration, freezing and air conditioning plant,
More informationAnchor Load Cells. Among the different types that are used as anchor load cells
Chapter: 3.1 Anchor Load Cells Page No.: 1 Number of Pages: 1 In rock and base engineering anchors are applied as construction element. They stabilise the rock by absorbing axial load and shear forces.
More informationVALVCHEQ BACKFLOW PREVENTERS FIGURE RP03
Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections FEATURES GENERAL APPLICATION The RP03 provides protection from both backsiphonage and backpressure
More informationHydraulic hand spindle pump Models CPP1000-M, CPP1000-L
Calibration Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L WIKA data sheet CT 91.05 for further approvals see page 2 Applications Calibration service companies and service industry Calibrations
More informationFisher DVI Desuperheater Venturi Inline
Instruction Manual DVI Desuperheater Fisher DVI Desuperheater Venturi Inline Contents Introduction... 1 Scope of Manual... 1 Description... 1 Principle of Operation... 2 Installation... 3 Operating Instructions...
More informationGas powered stop valves, type GPLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Gas powered stop valves, type GPLX 80-150 REFRIGERATION AND AIR CONDITIONING Technical leaflet Technical leaflet Gas powered stop valves, type GPLX 80-150 Contents Page Introduction........................................................................................3
More informationSLAM-SHUT VALVES. Type BM5. Process Management TM
SLAM-SHUT VALVES Type BM5 Process Management TM BM5 Slam-Shut Valves Slam-shut valves BM5 series slam-shut valve is an automatic shut-off appliance suitable for installation as safety device in regulating
More informationPilot HON 625. Entwurf. Product information. serving the gas industry worldwide
Pilot HON 62 Entwurf Product information serving the gas industry worldwide Pilot HON 62 Application, characteristics Application Pilot for the gas pressure regulator HON 02 Pilot for outlet pressure control
More informationinstruction manual highpressure handpump manual
instruction manual highpressure handpump manual Introduction The FX pump is designed, manufactured and tested by FX Airguns AB in Sweden. There are two patented systems. The first of them is the 3 stage
More informationModel NDA Differential pressure transmitter. Deltapi N Series A complete range of pneumatic pressure transmitters
Data Sheet DS/NDA-EN Rev. H Model NDA Differential pressure transmitter Deltapi N Series A complete range of pneumatic pressure transmitters Introduction The blind type differential pressure transmitter
More informationR300 HELYON. Brass high pressure regulator, for compressed air, gas and liquids
HELYON 5 Chemin du Jubin 69570 DARDILLY Tél. +33 (0)4 72 52 16 70 - Fax +33 (0)4 72 52 16 71 R300 Brass high pressure regulator, for compressed air, gas and liquids FEATURES Pressure regulator for inlet
More informationLeak free Pipe Rupture Valve for Excavators
Leak free Pipe Rupture Valve for xcavators Series motion and progress Reference: 3 P 9575 1/11.6 Classification: 43.325.355...325.35 1/17 Contents Page 1 General description................................................................
More informationMUELLER. Mega-Lite Drilling Machine. Reliable Connections. table of contents PAGE. Equipment 2. Operating Instructions 3-4. Parts Information 5
operating Instructions manual MUELLER Mega-Lite Drilling Machine table of contents PAGE Equipment 2 Operating Instructions 3-4 Parts Information 5 Travel Charts 6-11! WARNING: 1. Read and follow instructions
More informationMechanical Pressure Measurement
Mechanical Pressure Measurement Differential Pressure Gauges Model GDP, Universal Version, with Diaphragm Element High Overpressure Safety PN 40, 100, 250 or 400 Applications Differential pressure measurement
More informationPressure-limiting valve and pre-load valve type MVG, MVE and MVP
Pressure-limiting valve and pre-load valve type MVG, MVE and MVP Product documentation Directly controlled Operating pressure pmax: Flow rate Qmax: 700 bar 8 lpm D 3726 02-2016-1.3 by HAWE Hydraulik SE.
More informationValve test benches. Systems overview
Valve test benches Systems overview About us In the past few years WIKA has successfully integrated renowned manufacturers of calibration equipment into the group. With these established brands within
More informationSERVICE MANUAL. Technical Bulletin No GEOPROBE GH40 HYDRAULIC HAMMER. PREPARED: February, REVISED: April, 2002 A DIVISION OF KEJR, INC.
This document describes charging the GH40 Hydraulic Hammer with nitrogen gas. Text and illustrations were taken directly from the service manual shown below. GEOPROBE GH40 HYDRAULIC HAMMER SERVICE MANUAL
More informationNeotecha Tank Sampling Sapro
Tank sampling system for representative sampling without process interruption Features The sampling system assures a true representative sample every time without process interruption. The sampling system
More informationTypes ACE95 and ACE95Sr Tank Blanketing Valves
October 2014 Types ACE95 and ACE95Sr Tank Blanketing Valves W9133 W8155 Figure 1. Type ACE95 Tank Blanketing Valve Figure 2. Type ACE95Sr Tank Blanketing Valve Features Fully Balanced Pilot Design Reduces
More informationLiquid level regulating valves Types PMFL / PMFH and SV
Data sheet Liquid level regulating valves Types / PMFH and SV For modulating liquid level control in refrigeration, freezing and air conditioning plant, a system comprising a liquid level regulating valve
More informationQuick Start Guide LIQ-QSG-499AOZ, Rev M July Rosemount 499AOZ. Dissolved Ozone Sensor
Quick Start Guide LIQ-QSG-499AOZ, Rev M July 2017 Rosemount 499AOZ Dissolved Ozone Sensor Safety information CAUTION! SENSOR/PROCESS APPLICATION COMPATIBILITY The wetted sensor material may not be compatible
More informationTechcon Systems TS1254 Pressure Pot
Techcon Systems TS1254 Pressure Pot User Guide Copyright OK International, Inc. TABLE OF CONTENT 1. SAFETY. 3 1.1 Intended Use 3 1.2 Safety Precaution 3 2. FEATURES. 5 3. SPECIFICATIONS 4 4. INSTALLATION
More informationVALVCHEQ BACKFLOW PREVENTERS FIGURE RP03
Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections FEATURES GENERAL APPLICATION The RP03 provides protection from both backsiphonage and backpressure
More informationFisher and Whisper Disk Diffusers
Instruction Manual Inline and Vent Diffusers Fisher 6010 -- 6015 and Whisper Disk Diffusers Contents Introduction... 2 Scope of Manual... 2 Description... 2 Principle of Operation... 3 Piping Considerations...
More informationTypes 627W and 627WH Direct-Operated Pressure Reducing Liquid Regulators
Types 627W and 627WH Direct-Operated Pressure Reducing Liquid Regulators Introduction The Types 627W and 627WH are direct-operated pressure reducing regulators for liquid service. They are available in
More informationCertified Accuracy. Ring Force Gauge. Models and Capacities Available. Design and Principle of Operation
Certified Accuracy Ring Force Gauge The accurate measurement of mechanical forces is required in hundreds of applications from a simple weighing procedure to the calibration of testing machines and load
More informationFree Chlorine Sensor For additional information, please visit our website at
Instruction Manual 499ACL01 LIQ_MAN_ABR_499ACL01 April 2014 Free Chlorine Sensor For additional information, please visit our website at www.rosemountanalytical.com. CAUTION Sensor/Process Application
More informationATS430 turbidity sensor Retractable insertion assembly
A MEASUREMENT & ANALYTICS INSTRUCTION ATS430 turbidity sensor Retractable insertion assembly Measurement made easy 1 Introduction This publication details installation procedures for the retractable insertion
More informationDissolved Oxygen Sensor
Instruction Manual 499ADO and 499ADO-VP LIQ_MAN_ABR_499ADO May 2014 Dissolved Oxygen Sensor CAUTION For additional information, please visit our website at www.rosemountanalytical.com SENSOR/PROCESS APPLICATION
More informationRESIDENTIAL REGULATORS
RESIDENTIAL REGULATORS Type B NG Process Management TM B NG Regulators Description! BODY RESISTANT TO HIGHER PRESSURES Various Springs Adaptable to various fluids (Natural Gas, LPG, Manufactured Gas, etc.)!
More informationInstallation, Operation, & Maintenance Manual NX Seal Cooler
Installation, Operation, & Maintenance Manual NX Seal Cooler 1 1. INTRODUCTION 1.1 About this Manual This manual is intended to ensure a safe installation and operation of the NX sealcooler. All involved
More informationSIKA Ba_ODWT15_en 05/2018. Operating manual for oil deadweight tester 0.015% accuracy ODWT15
SIKA Ba_ODWT15_en 05/2018 Operating manual for oil deadweight tester 0.015% accuracy ODWT15 Table of Contents 1 introduction...1 1.1 general product description... 1 1.2 operating principle... 1 2 general
More informationPressure Sensing Valve - Model 4023
Pressure Sensing Valve - Model 4023 Overview AMOT Model 4023 can be used as a 2 or 3-way capacity, pressure sensing valve. This valve is ideal for applications that require compressor suction and discharge
More informationTransferpette. Lightweight precise rugged reliable!
Lightweight precise rugged reliable! Transferpette Solutions for S cience F I R S T C L A S S B R A N D The Transferpette S microliter pipettes provide all features required for pipetting in Life Science
More information1.0 - OPENING AND CLOSING THE DOOR
The purpose of this manual is to provide the user with instructions on how to safely open and close, how to conduct routine maintenance, and how to install the PEI TWINLOCK Closure on a pressure vessel.
More informationTransferpette. Lightweight precise rugged reliable!
Lightweight precise rugged reliable! Transferpette Solutions for S cience F I R S T C L A S S B R A N D The Transferpette S microliter pipettes provide all features required for pipetting in Life Science
More informationProportional Relief Valves
www.swagelok.com Proportional Relief Valves R Series Liquid or gas service Set pressures from 10 to 6000 psig (0.68 to 413 bar) 1/4 and 1/2 in. and 6 to 12 mm end connections 2 Proportional Relief Valves
More informationType Y692 Gas Blanketing Regulator System
Bulletin 7:Y69 Type Y69 Gas Blanketing Regulator System November 14 W930-1 Figure 1. Type Y69 Low-Pressure Gas Blanketing Regulator Introduction An Accu-Pressure Gas Blanketing Regulator System reduces
More informationINSTALLATION, OPERATION AND MAINTENANCE MANUAL. Model Sanitary Vent SECTION I
INSTALLATION, OPERATION AND MAINTENANCE MANUAL Model 1100 Sanitary Vent IOM-1100 03-17 ISO Registered Company SECTION I I. DESCRIPTION AND SCOPE The Model 1100 is a stainless steel sanitary vent designed
More informationCommon Discrepancies Uncovered on ADCI Diving Contractor & Training Program Audits
Common Discrepancies Uncovered on ADCI Diving Contractor & Training Program Audits Ways to Set Your Company or School Up For Success on ADCI Audits and Reduce Costs In most instances, all discrepancies
More informationFloat Operated Level Controllers
CONTENTS Float Operated Level Controllers IM0015 Nov. 2014 PAGE Introduction 1 Scope 1 Description 1 Specification 1 Control Installation 2 INTRODUCTION Side Mount Back Mount Prior to installing, the instructions
More informationHydraulic Accumulators with Back-Up Nitrogen Bottles
Hydraulic Accumulators with Back-Up Nitrogen Bottles 1. GENERAL To complete the accumulator range, HYDAC provides a variety of useful accessory products. They guarantee correct installation and optimum
More informationDANFLO Liquid Surge Relief Valve
DANFLO Liquid Surge Relief Valve DANFLO Surge Relief Valves DANFLO Surge Relief Valves are engineered to track unabated surge-wave pressure transients-open quickly, then closes without slamming shut. The
More informationP5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.
Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com P5513 Pneumatic Comparison Test Pump Users Manual PN 3963372 November 2010 2010 Fluke Corporation. All
More informationNB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE
NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE INSTALLATION, OPERATION & MAINTENANCE MANUAL INTERFACE DEVICES, INC. 230 Depot Road, Milford, CT 06460 Ph: (203) 878-4648, Fx: (203) 882-0885, E-mail: info@interfacedevices.com
More informationDK ton, Double-acting, Die-type Crimping Tool
INSTRUCTION MANUAL DK6040 60-ton, Double-acting, Die-type Crimping Tool Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Register
More informationType ACE95jr Tank Blanketing Valve
Type ACE95jr Tank Blanketing Valve Features Fully Balanced Plug Design Reduces Inlet Pressure Sensitivity Bulletin 74.1:ACE95JR May 2010 Stainless Steel Construction Available High Sensitivity Self-Contained
More informationCOSASCO 6000 PSI SINGLE ISOLATION SERVICE VALVE (FR) MAINTENANCE
COSASCO 6000 PSI SINGLE ISOLATION SERVICE VALVE (FR) MAINTENANCE 11841 Smith Avenue Santa Fe Springs, CA 90670 Tel: (562) 949-0123 (800) 635-6898 Fax: (562) 949-3065 www.cosasco.com Page: 2 of 26 Revision
More informationFisher 2625 and 2625NS Volume Boosters
Product Bulletin D200071X012 2625 and 2625NS Volume Boosters Fisher 2625 and 2625NS Volume Boosters A Fisher 2625 or 2625NS volume booster (figure 1) is used in conjunction with a positioner on a throttling
More informationSafeguarding your process flow control system
Safeguarding your process flow control system 1 Cavitation Understanding Flashing and Cavitation and flashing are major causes of metal erosion in flow control systems. It occurs when a media goes through
More informationPressure Dump Valve Service Kit for Series 2300 Units
Instruction Sheet Pressure Dump Valve Service Kit for Series 00 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00 applicator tanks when the unit
More informationWelker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual
Installation, Operation, and Maintenance Manual Welker Sampler Model GSS-1 The information in this manual has been carefully checked for accuracy and is intended to be used as a guide to operations. Correct
More informationMicro Motion 3098 Gas Specific Gravity Meter
Product Data Sheet PS-001188, Rev. B April 2009 Micro Motion 3098 Gas Specific Gravity Meter Micro Motion density and concentration meters are built to tackle the most demanding process and fiscal applications.
More informationCutting device S-16. Operating Instructions Habasit AG Postfach, CH-4153 Reinach-Basel Phone Fax
Habasit AG Postfach, CH-4153 Reinach-Basel Phone ++41 61 715 15 15 Fax ++41 61 715 15 55 Operating Instructions 3890 Author: Nyk Page 1 of 8 Replaces: - The cutting device is a manual cutting tool to cut
More informationType 4660 High-Low Pressure Pilot
Product Bulletin Type 4660 High-Low Pressure Pilot The Type 4660 pneumatic high-low pressure pilot (figure 1) activates safety shutdown systems for flowlines, production vessels, and compressors. This
More informationAging Cell, OFITE Style. Included Items
DRILLING FLUIDS EQUIPMENT For over 30 years OFI Testing Equipment (OFITE) has provided instruments and reagents for testing drilling fluids, well cements, completion fluids, and wastewater. In addition
More informationREGULATORS FLOWMETERS HUMIDIFIERS. Professional GAUGES ASSESSORIES. Medical Apparatus. and Assessories ISO 13485/ISO 9001 CERTIFICATION
Medical Apparatus REGULATORS FLOWMETERS Professional Medical Apparatus and Assessories HUMIDIFIERS GAUGES ASSESSORIES ISO 13485/ISO 9001 CERTIFICATION Company Profile MORRIS ENGINEERING WORKS LTD. was
More informationAIR STAPLER MODEL: CSG1C Part No
AIR STAPLER MODEL: CSG1C Part No. 3110375 0506 OPERATING & MAINTENANCE INSTRUCTIONS SPECIFICATIONS Min. Hose Size (ID)... 6mm (1/4 ) Air Inlet Connector... 10mm Quick Fit Ave. Air Consumption... 0.27 cfm
More information